#1. What is RPCU? What are the logic conditions for RPCU to open the Out Flow Valve?
The Residual Pressure Control Unit (RPCU) automatically depressurizes the aircraft in the event of abnormal residual pressure on the ground. It opens the outflow valve when:
- The aircraft is on the ground,
- Both CPCs have failed or manual mode is selected, and the outflow valve is not fully open,
- All ADIRS indicate an airspeed below 100 knots, or all engines are shut down