Results

#1. What will happen when you press both Blower & Extract P/B to OVRD? Name some situations when you have to push both Blower & Extract p/b to OVRD?

If both the Blower and Extract switches are set to Override, the Blower fan stops while the Extract fan continues running. Air-conditioning air is used for avionics ventilation, and the system enters Intermediate Configuration