A320 Aircraft Systems · Chapter 1
Air Conditioning Two packs, a mixer unit, trim air and two controllers: how the A320 turns hot bleed air into a comfortable cabin in three zones.
A A I I R R C C O O N N D D PACK FLOW NORM LO HI PACK 1 FAULT OFF PACK 2 FAULT OFF HOT AIR FAULT OFF COCKPIT COLD HOT FWD CABIN COLD HOT AFT CABIN COLD HOT PACK 1 PACK 2 ENG 1 BLEED APU BLEED ENG 2 BLEED FAULT OFF FAULT ON FAULT OFF X BLEED SHUT AUTO OPEN RAM AIR ON COND TEMP : °C FAN FAN CKPT 21 18 C H FWD 22 24 C H AFT 23 26 C H HOT AIR © 2026 eatpl.in. For the personal study of eatpl.in students only. Do not copy or distribute.
e-books by eatpl.in · © 2026 · Do not copy or distribute
Welcome to the first lesson of the A320 systems course: air conditioning. Every minute of every flight, two packs take hot, high-pressure bleed air and turn it into cool, dry air for the passengers and for you on the flight deck. In this lesson we follow that air from the pack flow control valves, through the heat exchangers and the air cycle machine, into the mixer unit, and out to three temperature zones. You will learn what the two controllers do, how trim air fine tunes each zone, every switch on the AIR COND panel, what the ECAM pages show, and exactly what happens when something fails. These are favourite topics in type-rating ground school and in airline interviews, so let us get started.
Roadmap
Hot bleed air in, comfortable cabin out 1 · The big picture Three zones, the air path from bleed to cabin, and the architecture.
2 · The pack Pack flow control valve, heat exchangers, air cycle machine, bypass valve, ram air flaps.
3 · Mixing and temperature Mixer unit, recirculation, trim air, the ACSCs, temperature and flow regulation.
4 · Cockpit and failures AIR COND panel, ECAM BLEED, COND and CAB PRESS pages, failure cases and RAM AIR.
Chapter 1 · Air Conditioning
2
e-books by eatpl.in · © 2026 · Do not copy or distribute
This lesson has four parts. First the big picture: what the air conditioning system does, the three temperature zones, and the path the air takes from the pneumatic system to the cabin. Second, the pack itself: the pack flow control valve, the two heat exchangers, the air cycle machine with its compressor, turbine and fan, and the bypass valve and ram air inlet flap that control its temperature. Third, mixing and temperature control: the mixer unit, recirculation, trim air, the two air conditioning system controllers and the flow selector. Finally, the cockpit view: every control on the AIR COND panel, the ECAM pages, and what happens when parts of the system fail, including emergency ram air. Keep one idea in mind throughout: the packs make the air cold, and trim air makes each zone warm again.
Part 1 · The big picture
Fully automatic, three independent zones COCKPIT FWD CABIN AFT CABIN PACKS MIXER Conditioned air to all three zones Mixer unit pack air + recirculated cabin air Bleed air from the engines (or APU) Two packs in the belly fairing Out through the outflow valve Pneumatic air → 2 pack flow control valves → 2 packs → mixer unit (+ recirculated cabin air) → COCKPIT , FWD CABIN , AFT CABIN , each at its own selected temperature.
Chapter 1 · Air Conditioning
3
e-books by eatpl.in · © 2026 · Do not copy or distribute
The A320 air conditioning system is fully automatic. It renews the air continuously and holds a constant, selected temperature in three zones: the cockpit, the forward cabin and the aft cabin, each controlled independently. Watch the scene. Bleed air from the pneumatic system, normally from the engines or the APU, runs to the two packs. The packs sit low in the fuselage, in the belly fairing. They cool the air, and it then goes to a mixer unit where it is mixed with filtered cabin air. From there, conditioned air rises into the ducts and is spread along the cockpit and the cabin. Finally, the air leaves through the outflow valve at the rear, which belongs to pressurisation, our next lesson. In normal operation the crew only selects temperatures and checks the indications.
Part 1 · The big picture
The architecture on one page COCKPIT FWD CABIN AFT CABIN Hot air pressure regulating valve Trim air valves one per zone Pack flow control valve PACK 1 ACSC 1 Pack flow control valve PACK 2 ACSC 2 MIXER UNIT Cabin air recirculation fan + filter Cabin air recirculation fan + filter LP ground connection Emergency ram air inlet Hot bleed air Conditioned (cold) air Trim (hot) air Recirculated cabin air Controller signal
Chapter 1 · Air Conditioning
4
e-books by eatpl.in · © 2026 · Do not copy or distribute
Here is the whole system on one page, and it is worth learning by heart. At the bottom, bleed air enters through two pack flow control valves, one for each pack. Each pack is run by its own controller: ACSC 1 for pack 1 and ACSC 2 for pack 2. The cold air from both packs goes up into the mixer unit. At both ends of the mixer, recirculation fans pull cabin air back in through filters. The mixer also has two more inlets: the low pressure ground connection, for a ground air cart, and the emergency ram air inlet. From the mixer, three risers carry air to the cockpit, the forward cabin and the aft cabin. Now the orange line: some hot air is tapped off upstream of the packs, through the hot air pressure regulating valve, into a trim air manifold. A trim air valve on each riser adds just enough hot air to warm that zone to its target.
Part 2 · The pack
The pack flow control valve One per pack: the gateway from the pneumatic system into the pack Pneumatically operated, electrically controlled ; the ACSC modulates it to regulate pack flow No air pressure: a spring holds it closed Closes with the PACK pb OFF , low upstream pressure, compressor outlet overheat, engine start , ENG FIRE pb or DITCHING Its position is shown on the BLEED page ; PACK pb FAULT if it disagrees with the selection Pack flow control valve Spring: closes the valve with no air pressure Pneumatically operated, electrically controlled. The ACSC sets its opening to regulate the pack flow. PACK pb-sw selected OFF Upstream pressure below minimum Compressor outlet overheat Engine start (see the start slide) ENG FIRE pb pressed on that side DITCHING pb selected OR Valve CLOSES
Chapter 1 · Air Conditioning
5
e-books by eatpl.in · © 2026 · Do not copy or distribute
Each pack has a pack flow control valve at its inlet. It is the gateway between the pneumatic system and the pack. The valve is pneumatically operated and electrically controlled: air pressure moves it, and the controller decides how far it opens, which is how the pack flow is regulated. With no air pressure, a spring holds it closed. Now learn the list of things that close it, because it is a favourite question. The PACK pushbutton selected off. Upstream pressure below the minimum. A compressor outlet overheat. The engine start sequence, which has its own slide later. The engine fire pushbutton on that side. And the ditching pushbutton. The fire case makes sense: you do not want to draw air from a burning engine into the cabin. The ditching case closes every opening below the waterline.
Part 2 · The pack
Inside the pack: the cooling path Bleed air → primary heat exchanger : first cooling → ACM compressor : pressure and temperature rise → main heat exchanger : cooled again; water separator dries it → ACM turbine : expands, does work, gets very cold The turbine drives the compressor and the cooling air fan on one shaft Ram air cools both heat exchangers; it never enters the cabinPack cooling path Ram air Ram air inlet flap Main HX Primary HX FAN overboard Compressor Turbine Water separator to the mixer unit Pack flow control valve Bypass valve (C shut ... H open)
Chapter 1 · Air Conditioning
6
e-books by eatpl.in · © 2026 · Do not copy or distribute
Let us follow the air through one pack. Warm bleed air comes in through the pack flow control valve and goes first into the primary heat exchanger, where outside air takes away some heat. Next it enters the compressor of the air cycle machine, which raises its pressure and, of course, its temperature. It is then cooled again in the main heat exchanger. Before the turbine, a water separator dries the air, so we do not blow fog or ice into the cabin. Finally the air expands through the turbine. As it expands it does work, driving the compressor and the cooling air fan on the same shaft, and losing that energy makes it very cold. The fan pulls ram air through both heat exchangers. Remember, ram air is only a coolant. The cold air leaves the pack and goes on to the mixer unit.
Part 2 · The pack
Why the turbine makes the air cold Energy out = temperature down: the turbine extracts work from the air Compressing first is the trick: it makes the air hotter than ram air , so the main heat exchanger can dump more heat Then the higher pressure gives the turbine more expansion and a bigger temperature drop ECAM limits: compressor outlet amber above 260 °C , pack outlet amber above 90 °C Numbers on the graph are illustrative ; only the amber limits are type data Temperature and pressure through the pack 0 100 200 300 Temperature, °C (illustrative) compressor outlet amber above 260 °C pack outlet amber above 90 °C Bleed in After primary HX After compressor After main HX After turbine Pressure (relative)
Chapter 1 · Air Conditioning
7
e-books by eatpl.in · © 2026 · Do not copy or distribute
Why does a pack work at all? The key is energy. When air expands through a turbine and drives a shaft, the energy it gives up comes out of its own heat, so its temperature falls sharply. That is why the turbine discharge is so cold. But why compress the air first, only to cool it again? Because compressing it makes it much hotter than the outside ram air, so the main heat exchanger can throw away a lot of heat. And the extra pressure gives the turbine more expansion to work with, so the final temperature drop is bigger. Look at the graph: hot in, cooled, hotter again, cooled, and then well below zero after the turbine. These temperatures are only illustrative. The two numbers to learn are the ECAM amber limits: compressor outlet above two hundred and sixty degrees, and pack outlet above ninety degrees.
Part 2 · The pack
Pack temperature: bypass valve and ram air flap Each ACSC controls its own pack outlet temperature It modulates the bypass valve : warm air round the turbine. More open = warmer And the ram air inlet flap : more cooling air = colder BLEED page needle C … H shows the bypass valve: C = closed (cold), H = open (hot) The flap closes for take-off and landing to keep foreign objects out Pack temperature control Ram air Ram air inlet flap Main HX Primary HX FAN overboard Compressor Turbine Water separator to the mixer unit Pack flow control valve Bypass valve (C shut ... H open)
Chapter 1 · Air Conditioning
8
e-books by eatpl.in · © 2026 · Do not copy or distribute
Each air conditioning system controller, or ACSC, controls the outlet temperature of its own pack with two devices. The first is the ram air inlet flap. Watch it: as the flap opens, more outside air flows through the heat exchangers and the pack can make colder air. The second is the bypass valve. It takes warm air from the primary heat exchanger and sends it straight to the turbine outlet, around the air cycle machine. Open it more and the outlet gets warmer; close it and the outlet gets colder. On the BLEED page the bypass valve is the needle between C and H: C means the valve is closed, cold; H means it is open, hot. Now watch the flap at the end: for the takeoff run it closes completely, and the same happens on landing, so that the pack does not swallow stones and debris from the runway.
Part 2 · The pack
Ram air inlet flaps on the runway Take-off : closes when TO power is set and the main gear struts are compressed Reopens after lift-off (struts extended) and goes back to normal modulation Landing : closes as soon as the main gear struts compress, if speed is 70 kt or more Reopens 20 s after the speed drops below 70 kt Purpose: no foreign object ingestion into the heat exchangers Ram air inlet flaps on the runway Take-off 0 80 160 IAS, kt TO thrust set lift-off flaps CLOSED open open Closes when TO power is set and the main gear struts are compressed. Landing 0 80 160 touchdown 70 kt below 70 kt +20 s flaps CLOSED open Close at touchdown if the speed is 70 kt or more; reopen 20 s after the speed drops below 70 kt. Why: no foreign objects sucked in.
Chapter 1 · Air Conditioning
9
e-books by eatpl.in · © 2026 · Do not copy or distribute
Here is the exact logic of the ram air inlet flaps on the runway, because examiners love the numbers. On take-off, the flaps close when take-off power is set and the main landing gear struts are compressed. Once the aircraft lifts off and the struts extend, that condition disappears and the controller goes back to modulating the flaps normally. On landing, the flaps close as soon as the main gear struts are compressed, provided the speed is seventy knots or more. They then stay closed until twenty seconds after the speed drops below seventy knots. So in a typical landing, the flaps reopen while you are taxiing off the runway. The reason is always the same: at high speed on the runway, the inlets could suck in water, stones and other debris, and that would damage the heat exchangers.
Part 3 · Mixing and temperature
The mixer unit and recirculation Mixes cold fresh pack air with recirculated cabin air Two recirculation (cabin) fans pull cabin air back through filters CAB FANS pb (VENTILATION panel): ON = both fans run, OFF = both stopAlso connected: LP ground connection and emergency ram air inlet Outlets: three risers to cockpit , FWD and AFT cabin Mixer unit MIXER UNIT Cockpit FWD cabin AFT cabin Pack 1 Pack 2 Recirculation fan + filter Recirculation fan + filter LP ground Emergency ram air Cold pack air + filtered cabin air, mixed, then distributed to the three zones.
Chapter 1 · Air Conditioning
10
e-books by eatpl.in · © 2026 · Do not copy or distribute
All the conditioned air meets in the mixer unit. From below, it receives the cold, fresh air from pack 1 and pack 2. At its ends, two recirculation fans, also called the cabin fans, pull cabin air back through a cabin air filter and push it into the mixer. Mixing warm recirculated air with very cold pack air gives a comfortable supply temperature and keeps a good total flow through the cabin, without having to take all of it as fresh bleed air. The fans are controlled by the CAB FANS pushbutton on the VENTILATION panel: on, both fans run; off, both stop. Two more inlets join the mixer. The low pressure ground connection lets a ground air cart condition the aircraft. And the emergency ram air inlet, normally shut, is our back-up source. From the mixer, risers carry the air to the cockpit, the forward cabin and the aft cabin.
Part 3 · Mixing and temperature
Trim air: hot air added zone by zone MIXER UNIT: air at the temperature the coldest zone needs Hot air pressure regulating valve (ACSC 1) hot air from upstream of the packs trim valve shut COCKPIT selected 20 °C (coldest) trim valve open 85 % FWD CABIN selected 24 °C trim valve open 45 % AFT CABIN selected 22 °C Hot air tapped upstream of the packs → hot air pressure regulating valve (ACSC 1) → one trim air valve per zone: cockpit valve by ACSC 1 , cabin valves by ACSC 2 .
Chapter 1 · Air Conditioning
11
e-books by eatpl.in · © 2026 · Do not copy or distribute
The mixer unit makes air for the coldest zone, so the other zones need warming. That is the job of trim air. Hot air is tapped off upstream of the packs and passes through the hot air pressure regulating valve, which ACSC 1 controls. It feeds a trim air manifold that runs alongside the three risers. Each zone has its own trim air valve, electrically controlled, which adds hot air into that zone duct. The cockpit trim air valve belongs to ACSC 1, and the two cabin trim air valves belong to ACSC 2. In our example, the cockpit wants twenty degrees, the coldest selection, so its trim valve stays shut. The forward cabin wants twenty four, so its trim valve opens wide, and the aft cabin, at twenty two, opens it partly. Each zone ends up at its own temperature.
Part 3 · Mixing and temperature
The hot air pressure regulating valve Regulates the pressure of the hot air to the trim air valves; controlled by ACSC 1 Pneumatic, electrically controlled, spring-closed with no air Closes: HOT AIR pb OFF , both lanes of ACSC 1 failed, duct overheat Also closes: cockpit trim valve failed, or both cabin trim valves failed Keeps working if only one cabin trim valve fails Hot air pressure regulating valve hot air in to trim valves Spring-closed with no air. Regulated by ACSC 1. Closes HOT AIR pb-sw selected OFF Both lanes of ACSC 1 failed Duct overheat detected Cockpit trim air valve failed BOTH cabin trim air valves failed Stays working Only the FWD or only the AFT cabin trim air valve failed When it closes, the trim air valves close too: optimised regulation is lost.
Chapter 1 · Air Conditioning
12
e-books by eatpl.in · © 2026 · Do not copy or distribute
The hot air pressure regulating valve sits between the hot air supply and the trim air manifold. It regulates the pressure of the hot air, so that the trim air valves can meter it accurately. ACSC 1 controls it. Like the pack valve, it is pneumatically operated and electrically controlled, and a spring closes it when there is no air. Learn when it closes. When the crew selects the HOT AIR pushbutton off. When both lanes of ACSC 1 fail. When a duct overheat is detected. When the cockpit trim air valve fails. And when both cabin trim air valves fail. Notice the trap: if only one cabin trim valve fails, the forward or the aft, the hot air valve stays open and the other two zones keep their trim air. Whenever the hot air valve closes, the trim air valves close too.
Part 3 · Mixing and temperature
Who controls what Most aircraft have two Air Conditioning System Controllers (ACSC) . Each has two lanes : one active, the other ready to take over.
Controller Pack Zone temperature Valves it drives ACSC 1 Pack 1: bypass valve, ram air inlet flap, pack flow control valve Cockpit Cockpit trim air valve, hot air pressure regulating valve ACSC 2 Pack 2: bypass valve, ram air inlet flap, pack flow control valve FWD and AFT cabin FWD and AFT cabin trim air valves Both ACSCs Can ask for more bleed pressure (EIUs) or more APU flow (ECB) Lowest demand sets both pack outlets Pack flow per the PACK FLOW selection Older aircraft Two pack controllers, one per pack One zone controller for all three zones Zone controller drives the trim air valves
Exam tip: the cockpit belongs to number 1 (ACSC 1, pack 1, hot air valve); the cabin belongs to number 2.
Chapter 1 · Air Conditioning
13
e-books by eatpl.in · © 2026 · Do not copy or distribute
This table sorts out who controls what, a very common interview question. On most aircraft there are two air conditioning system controllers. ACSC 1 runs pack 1: its bypass valve, its ram air inlet flap and its pack flow control valve. It also regulates the cockpit temperature through the cockpit trim air valve, and it controls the hot air pressure regulating valve. ACSC 2 runs pack 2 in the same way and looks after the forward and aft cabin temperatures through the two cabin trim air valves. Each controller has two lanes. One controls the system and the other takes over if the active lane fails. Some older aircraft have a different arrangement: two pack controllers, one per pack, and a single zone controller for all three zones. The logic you are about to learn is the same in both.
Part 3 · Mixing and temperature
The coldest zone sets the packs Crew selects a reference temperature for each zone on the AIR COND panel The controller compares selected and actual temperature: a demand per zone Sensors: cockpit ; for the cabin, in the lavatory extraction and galley ventilation The lowest demand goes to the pack control: both packs make air for it Trim air then warms each other zone: optimised regulationWorked example: three different selections 16 18 20 22 24 26 28 30 Temperature, °C 20 °C Cockpit +4 trim 24 °C FWD cabin +2 trim 22 °C AFT cabin Lowest demand goes to the ACSCs: both packs make air for it. Trim air then warms each other zone to its own target. Zone sensors: cockpit; cabin in the lavatory extraction and galley ventilation.
Chapter 1 · Air Conditioning
14
e-books by eatpl.in · © 2026 · Do not copy or distribute
Here is the heart of temperature regulation. The crew sets a reference temperature for each zone with the selectors. The controller compares the selected temperature with the actual temperature in that zone and works out a temperature demand. The actual temperature comes from sensors: one in the cockpit, and for the cabin, sensors in the lavatory extraction circuit and the galley ventilation system. Now the clever part. The lowest demanded temperature is sent to the pack control, and both packs then produce air cold enough for that zone. Trim air then warms the other zones. In our worked example, the cockpit wants twenty degrees, the forward cabin twenty four and the aft cabin twenty two. Both packs supply air for twenty degrees. The forward cabin gets about four degrees of trim air, the aft cabin about two, and the cockpit none.
Part 3 · Mixing and temperature
Selector range and cabin crew fine tuning Selector range 18 °C (COLD) to 30 °C (HOT) ; 12 o'clock = 24 °C That is 64 °F to 86 °F , with 76 °F at 12 o'clock Cabin crew can adjust each cabin zone from the FAP during cruise Authority: only ± 2.5 °C (± 4.5 °F) around the cockpit selection Worked example: FWD set to 21 °C → cabin crew range 18.5 to 23.5 °C Selector range and cabin crew authority COLD 18 °C HOT 30 °C 12 o'clock = 24 °C Each tick = 3 °C (linear scale for teaching) FAP fine tuning, in cruise cabin zones only, ± 2.5 °C 18 20 22 24 26 black line: FWD selected 21 23.5 18.5 Cockpit selects 21 °C for the FWD cabin: cabin crew can set 18.5 to 23.5 °C. Range 18 to 30 °C (64 to 86 °F)
Chapter 1 · Air Conditioning
15
e-books by eatpl.in · © 2026 · Do not copy or distribute
The zone selectors run from eighteen degrees at the COLD stop to thirty degrees at the HOT stop, with twenty four degrees at the twelve o'clock position. In Fahrenheit that is sixty four to eighty six, with seventy six at twelve o'clock. The cabin crew also have a say. On the forward attendant panel there is a temperature control page, and during cruise they can adjust each cabin zone, but only within plus or minus two point five degrees of what the cockpit has selected. Work the example: you set the forward cabin to twenty one degrees. The cabin crew can then fine tune it anywhere between eighteen point five and twenty three point five degrees. They cannot override the cockpit beyond that band, and they have no authority over the cockpit zone at all.
Part 3 · Mixing and temperature
Pack flow: LO, NORM, HI PACK FLOW selector: LO 80 % , NORM 100 % , HI 120 % , for passenger load and conditionsSingle pack or APU bleed : HI automatically , whatever is selectedLO is raised to NORM if the cooling demand is not metOn the ground, both engines running: NORM limited to 90 % (85 % on some aircraft) Demand not met: ACSC asks the EIUs for a higher minimum idle , or the APU ECB for more flow Pack flow, per cent of normal 0 20 40 60 80 100 120 140 80 LO few pax, cool day 100 NORM normal 120 HI hot / wet, smoke 90 NORM, ground, both engines 120 one pack or APU bleed auto HI LO is automatically raised to NORM if the cooling demand is not met. On some aircraft: ECON FLOW pb (ON 80 %, OFF 100 %); ground limit 85 %.
Chapter 1 · Air Conditioning
16
e-books by eatpl.in · © 2026 · Do not copy or distribute
The PACK FLOW selector sets how much air the packs deliver: LO is eighty per cent, NORM one hundred and HI one hundred and twenty. Use LO with few passengers and HI in hot, humid conditions or to clear smoke. Some aircraft have an ECON FLOW pushbutton instead, which gives eighty per cent when on. Two automatic rules override the selection. With only one pack running, or with the APU supplying bleed air, the system delivers high flow whatever is selected. And if LO is selected but a zone cannot be cooled enough, the flow goes up to normal. On the ground with both engines running, normal flow is limited to ninety per cent. Finally, if a zone still cannot be cooled because bleed pressure is too low, the controller asks both engine interface units to raise the minimum idle. With APU bleed, it asks the APU to deliver more flow.
Part 4 · Cockpit and failures
The AIR COND panel A A I I R R C C O O N N D D PACK FLOW NORM LO HI PACK 1 FAULT OFF PACK 2 FAULT OFF HOT AIR FAULT OFF COCKPIT COLD HOT FWD CABIN COLD HOT AFT CABIN COLD HOT PACK 1 PACK 2 ENG 1 BLEED APU BLEED ENG 2 BLEED FAULT OFF FAULT ON FAULT OFF X BLEED SHUT AUTO OPEN RAM AIR ON PACK FLOW LO 80 · NORM 100 · HI 120 % PACK 1 pb-sw FAULT amber · OFF white Zone temperature selectors COLD 18 · 12 o'clock 24 · HOT 30 °C HOT AIR pb-sw hot air PRV + trim valves PACK 2 pb-sw RAM AIR pb (guarded) ON white Bleed controls (ENG BLEED, APU BLEED, X BLEED) share this panel: see pneumatics. VENTILATION (part) CAB FANS OFF ON: both cabin (recirculation) fans run No light = normal (the "dark cockpit"). Amber FAULT = something to act on. White OFF / ON = a selection away from normal.
Chapter 1 · Air Conditioning
17
e-books by eatpl.in · © 2026 · Do not copy or distribute
This is the AIR COND panel on the overhead. Top left, the PACK FLOW selector. Across the top, the three zone temperature selectors for the cockpit, forward cabin and aft cabin. Top right, the HOT AIR pushbutton, which controls the hot air valve and the trim air. On each side, the PACK 1 and PACK 2 pushbuttons. In the bottom row, the guarded RAM AIR pushbutton. The other buttons in that row, the engine and APU bleed and the crossbleed selector, belong to the pneumatic system and share this panel. Remember the Airbus dark cockpit philosophy: in normal flight no lights are on. An amber FAULT light needs your attention, usually with an ECAM caution. A white OFF or ON light tells you something has been selected away from its normal position. On the right is the CAB FANS pushbutton from the VENTILATION panel, which controls both recirculation fans.
Part 4 · Cockpit and failures
PACK pb-sw: ON, OFF and FAULT ON (no light): the pack flow control valve is under automatic control OFF (white): the valve closes FAULT (amber) + ECAM caution: valve position disagrees with the selection… or compressor outlet overheat , or pack outlet overheat On some aircraft, PACKS appears on the EWD with thrust levers at TOGA or FLX/MCT PACK pb-sw: the three states FAULT OFF ON (no light) Valve under automatic control: opens unless a closing condition exists. FAULT OFF OFF (white) Pack flow control valve closes. FAULT OFF FAULT (amber) Valve position disagrees with the selection, OR compressor outlet overheat, OR pack outlet overheat. ECAM caution. On some aircraft: PACKS shows on the EWD with thrust levers at TOGA or FLX/MCT.
Chapter 1 · Air Conditioning
18
e-books by eatpl.in · © 2026 · Do not copy or distribute
The PACK pushbutton has three states. Pushed in, with no light, the pack flow control valve is under automatic control and opens unless one of the closing conditions you learned exists. Released, the white OFF light comes on and the valve closes. The amber FAULT light, with an ECAM caution, comes on in three cases: when the valve position disagrees with the selected position, when the compressor outlet overheats, and when the pack outlet overheats. Think about what FAULT can mean in practice. If you selected OFF but the valve is stuck open, that is a disagreement. If the pack overheats, the valve closes automatically, and the light tells you why your pack stopped. On some aircraft, the engine warning display also shows PACKS when the thrust levers are in the TOGA or FLX MCT detent, as part of the bleed configuration status.
Part 4 · Cockpit and failures
Pack valves during engine start Starting ENG 2 on the ground 0 % 50 % 100 % N2 1 MODE IGN 2 MASTER ON, start valve opens 3 N2 50 %, start valve shuts 4 +60 s: valves reopen Crossbleed valve OPEN at engine start: BOTH pack valves close PACK 1 valve CLOSED open PACK 2 valve CLOSED open Crossbleed valve CLOSED: only the pack on the STARTING engine side closes PACK 1 valve open PACK 2 valve CLOSED open Reopening is delayed 60 s on the ground (30 s on some aircraft) so that the second engine start does not add another cycle. Crossbleed closed: the starting side closes at MODE IGN and stays closed while MASTER ON (or MAN START ON), start valve open and N2 < 50 % . Crossbleed open: both close.
Chapter 1 · Air Conditioning
19
e-books by eatpl.in · © 2026 · Do not copy or distribute
During engine start, the starter needs all the bleed air it can get, so the pack valves close. The exact logic is a classic question. With the crossbleed valve closed, the pack valve on the starting engine side closes as soon as the MODE selector goes to IGN, or crank. It stays closed while the master switch is on, or the manual start pushbutton is on, the start valve is open, and N2 is below fifty per cent. If the crossbleed valve is open at engine start, both pack flow control valves close, because the air for the starter comes from the common duct. On the ground the valves do not reopen at once: there is a delay of sixty seconds, or thirty seconds on some aircraft. The reason is simple: if the packs reopened between the two starts and then closed again for the second engine, you would get an extra closing cycle for nothing.
Part 4 · Cockpit and failures
HOT AIR pb-sw and duct overheat ON : hot air valve regulates hot air pressureOFF : hot air valve and trim air valves close ; the fault circuit resets FAULT amber + ECAM caution: duct reaches 88 °C (190 °F) Valve and trim valves close automatically FAULT goes out when duct temp is below 70 °C (158 °F) and OFF is selected Duct overheat and the HOT AIR FAULT light 0 20 40 60 80 100 40 50 60 70 80 90 100 time, s (example) Duct temperature, °C 88 °C: overheat detected 70 °C: reset possible COND page: duct temp amber at 80 °C FAULT OFF 1 · normal FAULT OFF 2 · 88 °C: valves close FAULT OFF 3 · below 70 °C + OFF
Chapter 1 · Air Conditioning
20
e-books by eatpl.in · © 2026 · Do not copy or distribute
The HOT AIR pushbutton controls the hot air pressure regulating valve. Pushed in, the valve regulates the hot air pressure normally. Selected off, the valve and all the trim air valves close, and the fault circuit is reset. Follow the graph. A zone duct starts to overheat. When the duct temperature reaches eighty eight degrees Celsius, one hundred and ninety Fahrenheit, the amber FAULT light comes on with an ECAM caution, and the hot air valve and the trim air valves close automatically. With no more hot air, the duct cools down. The FAULT light only goes out when two things are true: the temperature is below seventy degrees, and the crew has selected the pushbutton off. On the COND page, notice that the duct temperature turns amber earlier, at eighty degrees, which gives you an early warning before the overheat.
Part 4 · Cockpit and failures
Emergency ram air PACKS OFF MIXER Emergency ram air inlet outside air → mixer unit → cabin Check valve stays shut while Δp ≥ 1 psi: no flow Both packs off ram air is the only fresh air Outflow valve about 50 % open only under automatic control RAM AIR pb ON · DITCHING not selected RAM AIR pb ON (and DITCHING normal): inlet opens. Δp < 1 psi : air flows to the mixer; outflow valve about 50 % open if in auto . Δp ≥ 1 psi : check valve stays shut, no flow.
Chapter 1 · Air Conditioning
21
e-books by eatpl.in · © 2026 · Do not copy or distribute
The emergency ram air inlet ventilates the cockpit and cabin to remove smoke, or when both packs are lost. In the scene, both packs are gone. The crew selects the guarded RAM AIR pushbutton on: the white ON light comes on, a green RAM AIR ON memo appears, and, provided ditching is not selected, the emergency ram air inlet opens. Now the important condition: the differential pressure. Only when cabin differential pressure is below one psi does outside air flow through the inlet straight to the mixer unit. At the same time, if the outflow valve is under automatic control, it opens to about fifty per cent so the air can flow through the cabin. In manual mode it does not open by itself. If the differential pressure is one psi or more, a check valve behind the ram air door stays shut and no air comes in at all, even though the door is open.
Part 4 · Cockpit and failures
ECAM BLEED page: the pack indications BLEED 24 °C C H 165 °C LO HI 25 °C C H 165 °C LO HI RAM AIR ANTI ICE ANTI ICE PSI °C 42 180 1 PSI °C 42 180 2 APU TAT +12 °C SAT -6 °C 10 H 42 GW 64300 KG BLEED 95 °C C H 270 °C LO HI 25 °C C H 165 °C LO HI RAM AIR ANTI ICE ANTI ICE PSI °C 42 180 1 PSI °C 42 180 2 APU TAT +12 °C SAT -6 °C 10 H 42 GW 64300 KG NORMAL (left) PACK 1 OVERHEAT (right) Pack outlet temp amber above 90 °C Bypass valve C – H C = shut (cold), H = open Compressor outlet amber above 260 °C Pack flow LO – HI amber when the valve is shut Pack valve symbol in line open, across shut Valve symbol amber position disagrees RAM AIR (centre) emergency ram air inlet User triangles amber in flight: no air
Chapter 1 · Air Conditioning
22
e-books by eatpl.in · © 2026 · Do not copy or distribute
The BLEED page shows each pack as a column. At the top, the pack outlet temperature, green, turning amber above ninety degrees. Below it, the bypass valve needle between C and H. Then the compressor outlet temperature, amber above two hundred and sixty degrees. Then the pack flow needle between LO and HI, around the pack flow control valve symbol. The valve symbol is green in line when open and green across the line when closed; it turns amber if its position disagrees with the command. The flow needle turns amber when the valve is closed. In the centre is the emergency ram air inlet symbol. The triangles at the top are the users; they turn amber in flight when there is no air for them, meaning both pack valves closed and the ram air inlet not fully open. On the right, pack 1 has overheated: amber temperatures, valve closed, flow needle amber. Note that the flow indication can read up to thirty per cent below the real flow.
Part 4 · Cockpit and failures
ECAM COND page COND TEMP : °C FAN FAN CKPT 21 18 C H FWD 22 24 C H AFT 23 26 C H HOT AIR COND TEMP : °C FAN FAN CKPT 23 20 C H FWD 26 81 C H AFT 24 25 XX C H HOT AIR NORMAL (left) FAULTS (right) FAN amber a recirculation fan fault Zone temp (top row) actual zone temperature Duct temp (bottom row) amber at 80 °C Trim valve arrow C shut ... H open; XX amber = failed HOT AIR valve across + amber: shut with pb OFF TEMP unit °C or °F in cyan Several faults drawn together for teaching. HOT AIR pb OFF after a FWD duct overheat: trim valves at C.
Chapter 1 · Air Conditioning
23
e-books by eatpl.in · © 2026 · Do not copy or distribute
The COND page shows the three zones. In each, the upper green number is the actual zone temperature, and the lower one is the duct temperature, which turns amber at eighty degrees. Under each zone, the trim air valve arrow moves between C, fully closed, and H, fully open. If a trim air valve fails, the arrow is replaced by two amber crosses. On the right, the hot air valve symbol: green in line when normally open, green across when normally closed. It shows amber when it disagrees with its command, or when it is closed with the HOT AIR pushbutton off. FAN appears amber if a recirculation fan is faulty, and the temperature unit, Celsius or Fahrenheit, is shown in cyan at the top right. The right-hand page shows several faults at once, for teaching: an amber fan, a hot forward duct, the hot air valve shut with the pushbutton off, all trim valves at C, and a failed aft trim valve.
Part 4 · Cockpit and failures
Packs on CAB PRESS, CRUISE and the memo CAB PRESS page: PACK 1 / PACK 2 with a triangle, normally green triangle , white legendBoth turn amber when the pack valve is closed with its engine running CRUISE page, AIR section: CKPT, FWD, AFT zone temperatures and the unitMemo RAM AIR ON in green while the RAM AIR pb is ON Quick check in cruise: zone temps on CRUISE, details on COND and BLEED Packs on other ECAM pages CAB PRESS (lower part of the page) PACK 1 PACK 2 normal valve shut, engine running CRUISE AIR CKPT 20 FWD 22 AFT 23 °C CAB V/S, CAB ALT and Δp are covered in pressurisation RAM AIR ON green memo while the RAM AIR pb is ON Zone temperatures on CRUISE are the same values as on COND.
Chapter 1 · Air Conditioning
24
e-books by eatpl.in · © 2026 · Do not copy or distribute
The packs also appear on other pages. At the bottom of the CAB PRESS page there is a small triangle and the words PACK 1 and PACK 2. Normally the triangle is green and the legend white, showing the pack is feeding the cabin. Both turn amber when that pack flow control valve is closed while its engine is running, which is exactly when you would expect the pack to be working. On the CRUISE page, the AIR section shows the cockpit, forward and aft zone temperatures, with the unit, so you can check comfort at a glance without calling the COND page. And when the RAM AIR pushbutton is on, a green RAM AIR ON memo appears on the engine warning display, as a reminder. A good habit in cruise: glance at the zone temperatures, and go to the COND and BLEED pages for detail if anything looks wrong.
Part 4 · Cockpit and failures
Failures at a glance Failure What happens ACSC: one lane fails No effect: the second lane takes over ACSC: both lanes fail Its pack is lost ; the hot air valve and the associated trim air valves close Hot air valve fails open No effect Hot air valve fails closed Optimised regulation lost, trim valves fully closed. Pack 1 → cockpit at the selected value; pack 2 → cabin at the mean of FWD and AFT selections One trim air valve fails Optimised regulation of that zone lost Air cycle machine seizes Pack can run in heat exchanger cooling mode , with reduced flow Duct overheat (88 °C) HOT AIR FAULT ; hot air valve and trim valves close Both packs lost RAM AIR pb ON for ventilation (works only below 1 psi Δp)
Chapter 1 · Air Conditioning
25
e-books by eatpl.in · © 2026 · Do not copy or distribute
Here are the failure cases in one table. Each controller has two lanes, so one lane failing has no effect. If both lanes fail, that pack is lost, and the hot air valve and the associated trim air valves close. If the hot air valve fails open, nothing changes. If it fails closed, optimised regulation is lost and the trim valves are driven fully closed. Pack 1 then controls the cockpit to its selected temperature, and pack 2 controls the whole cabin to the mean of the forward and aft selections. Work it out: forward twenty two, aft twenty six, so the cabin gets twenty four degrees. A single trim valve failure only costs optimised regulation in that zone. A seized air cycle machine has its own slide next. And when both packs are lost, emergency ram air is your ventilation, as long as the differential pressure is below one psi.
Part 4 · Cockpit and failures
Air cycle machine failure: heat exchanger cooling ACM seizure : compressor and turbine stop turning The pack can still run in heat exchanger cooling mode Air cooled in the primary heat exchanger goes mostly through the bypass valve , the rest through the seized ACM Pack flow is reduced ; trim air flow is lower too ACSC still regulates with the bypass valve , the ram air flap and the trim air valves Heat exchanger cooling mode Ram air Ram air inlet flap Main HX Primary HX FAN overboard Compressor Turbine ACM SEIZED Water separator to the mixer unit Pack flow control valve Bypass valve: open, most of the air
Chapter 1 · Air Conditioning
26
e-books by eatpl.in · © 2026 · Do not copy or distribute
What if the air cycle machine itself fails? Watch the scene: the compressor and turbine wheels seize and stop turning. The pack is not necessarily lost. It can be operated in heat exchanger cooling mode. Warm bleed air still comes in through the pack valve and is cooled in the primary heat exchanger by ram air. Then most of that air goes directly to the turbine outlet through the bypass valve, which now opens wide, and only the rest struggles through the seized machine. Without the turbine expansion, the air cannot get as cold, and the seizure also reduces the pack flow. The controller carries on as normal: it still regulates the temperature with the bypass valve and the ram air inlet flap, and still adds trim air, although less hot air is available because the pack flow is lower.
Summary
Air conditioning on one page Path Bleed → 2 pack flow control valves → 2 packs → mixer (+ recirculated air) → 3 zones.
The pack Primary HX, ACM compressor, main HX, water separator, turbine. Ram air only cools.
Pack control ACSC moves the bypass valve (C/H) and ram air flap; flap shut for TO and landing (70 kt, 20 s).
Temperature Lowest demand sets both packs; trim air warms the others. 18–30 °C, 24 at 12 o'clock; FAP ± 2.5 °C.
Controllers ACSC 1: pack 1, cockpit, hot air valve. ACSC 2: pack 2, cabins. Two lanes each.
Flow LO 80, NORM 100, HI 120 %. Auto HI with one pack or APU bleed. Ground, 2 engines: 90 %.
Panel PACK FAULT: disagree or overheat. HOT AIR FAULT at 88 °C, reset below 70 °C + OFF.
Failures Hot air valve shut: pack 1 cockpit, pack 2 cabin mean. ACM seized: HX cooling. RAM AIR below 1 psi.
Chapter 1 · Air Conditioning
27
e-books by eatpl.in · © 2026 · Do not copy or distribute
Let us pull it all together. Bleed air passes through two pack flow control valves into two packs, then into the mixer unit with recirculated cabin air, and on to three zones. Inside each pack, the primary heat exchanger, the compressor, the main heat exchanger, the water separator and the turbine make the air cold, and ram air only cools the exchangers. Each controller sets its pack temperature with the bypass valve and the ram air flap, which closes on the runway. The lowest zone demand sets both packs, and trim air warms the rest. ACSC 1 has pack 1, the cockpit and the hot air valve; ACSC 2 has pack 2 and the cabin. Know the flow percentages, the HOT AIR eighty eight and seventy degree thresholds, and the failure results, especially the hot air valve failing closed and the one psi limit for ram air. Now try the quiz.