A320 Aircraft Systems · Chapter 30
Auxiliary Power Unit The small gas turbine in the tail cone: what it supplies, how the ECB starts, runs and protects it, and how to read the APU panel and the ECAM APU page.
APU MASTER SW START FAULT ON AVAIL ON APU AVAIL APU GEN 26 % 115 V 400 HZ BLEED 35 PSI 0 10 N % 100 3 10 EGT °C 440 FLAP OPEN MASTER SW · START · AVAIL © 2026 eatpl.in. For the personal study of eatpl.in students only. Do not copy or distribute.
e-books by eatpl.in · © 2026 · Do not copy or distribute
Welcome to the auxiliary power unit. At the back of the A320, in the tail cone, sits a small jet engine that does not push the aircraft at all. Its job is to make bleed air and electricity, so that the aircraft can be independent of ground equipment, start its main engines, and have a back-up source in flight. In this lesson we look at what the APU supplies and when, how the engine and its electronic control box work, and how fuel, oil and air are handled. Then we move into the cockpit: the two pushbuttons on the APU panel, the start and shutdown sequences step by step, the automatic shutdowns and the ground fire protection, and finally the ECAM APU page.
Auxiliary power unit
Our route through ATA 49 1 Role 2 The engine 3 ECB and fuel 4 Bleed 5 APU panel 6 Start and stop 7 Protection 8 ECAM page What it is A self-contained gas turbine making bleed air and electrical power.
How it works Single shaft, ECB, intake flap, starter, fuel, oil, IGVs and bleed.
Operating it MASTER SW and START: start, AVAIL, shutdown, automatic and emergency stops.
Monitoring it The ECAM APU page: N, EGT, bleed, generator and advisories.
Chapter 30 · Auxiliary Power Unit
2
e-books by eatpl.in · © 2026 · Do not copy or distribute
Here is our route through chapter forty nine, the auxiliary power unit. We begin with its role: what it supplies on the ground, during take-off and in flight. Then we open it up: the single shaft gas turbine, the electronic control box that runs it, the air intake and its flap, the starter, the fuel and oil systems, the inlet guide vanes and the bleed. Third, the cockpit: the APU panel with its MASTER SW and START pushbuttons, the start sequence step by step, when AVAIL appears, and how the APU shuts down normally, automatically and in an emergency. Finally we read the ECAM APU page, including the colours of APU speed and exhaust gas temperature. Interviewers love the APU start sequence, so we will take that one slowly.
General
What the APU supplies A self-contained unit that supplies pneumatic and electrical power On the ground : bleed air to start the engines and for air conditioning ; electrical powerDuring take-off : bleed air for air conditioning, e.g. when best performance is neededIn flight : backs up the electrical system and the air conditioning ; can start the engines Starting power: batteries , the aircraft network or ground power ; starting allowed throughout the normal flight envelope ON THE GROUND Bleed air: engine start Bleed air: air conditioning Electrical power DURING TAKE-OFF Bleed air for air conditioning (e.g. for best performance) IN FLIGHT Electrical back-up Air conditioning back-up Engine starting Start power: batteries, aircraft network or ground power
Chapter 30 · Auxiliary Power Unit
3
e-books by eatpl.in · © 2026 · Do not copy or distribute
The APU is a self-contained unit in the tail cone that supplies the aircraft with two things: pneumatic power, which is bleed air, and electrical power. Watch both leave the tail. On the ground, its bleed air starts the main engines and feeds the air conditioning, and its generator powers the electrical system, so the aircraft does not need ground carts. During take-off, it can supply bleed air for the air conditioning, for example when the best aircraft performance is required, because then the engines do not have to give up bleed air. In flight, it backs up the electrical system and the air conditioning, and it can be used to start the engines. It can be started from the batteries, from the aircraft's normal electrical system or from ground power, anywhere in the normal flight envelope.
Main components
The APU engine A single-shaft gas turbine Shaft power drives the accessory gearbox : generator , starter and more It also produces bleed air for engine starting and the pneumatic system A load compressor feeds the APU bleed valve Air comes in through an intake with an electrically operated flap load compressor compressor combustor turbine GEARBOX generator starter oil pump APU bleed valve bleed air intake flap One shaft: turbine drives compressors and gearbox
Chapter 30 · Auxiliary Power Unit
4
e-books by eatpl.in · © 2026 · Do not copy or distribute
The basic element of the APU is a single shaft gas turbine. Everything turns together on one shaft. Air enters through the compressor, fuel burns in the combustion chamber, and the hot gas drives the turbine, which in turn drives the compressors and the accessory gearbox. The gearbox carries the generator and the starter, among other things. So the APU delivers its energy in two ways: mechanical shaft power to the gearbox, and compressed air. A separate load compressor on the same shaft provides the bleed air, which leaves through the APU bleed valve when it opens, towards the aircraft, for engine starting and the pneumatic system. Remember the phrase single shaft: one rotating assembly does all the work.
Electronic control box
The ECB: the APU's brain Full-authority digital electronic controllerSequences and monitors the start Monitors speed , temperature and bleed air Sequences the shutdown Controls the automatic shutdown Start: sequence and monitor Speed and temperature Bleed air Shutdown sequence Automatic shutdown ECB full-authority digital
Chapter 30 · Auxiliary Power Unit
5
e-books by eatpl.in · © 2026 · Do not copy or distribute
The APU is run by an electronic control box, the E C B. It is a full authority digital controller, which means that the crew does not set power or fuel flow; the E C B does all of it. It performs the bulk of the APU logic in every mode of operation. It sequences the start and monitors it, opening the flap, engaging the starter, switching on the ignition and so on. It monitors the speed and the temperature, and it monitors the bleed air. When you switch off, it sequences the shutdown. And it controls the automatic shutdown, which protects the APU when something goes wrong. Keep that in mind: whenever the APU does something by itself in this lesson, it is the E C B deciding.
Intake and starter
The intake flap and the starter The air intake and an electrically operated flap let outside air reach the compressor The ECB controls the electric starter The starter engages only if the flap is fully open and the MASTER SW is ON and the START pb is ONAir inlet flap closed is also an automatic shutdown case Air intake flap fully open MASTER SW ON START pb ON AND STARTER The ECB controls the electric starter The intake and an electrically operated flap let outside air reach the compressor inlet
Chapter 30 · Auxiliary Power Unit
6
e-books by eatpl.in · © 2026 · Do not copy or distribute
The APU breathes through an air intake on the tail cone, which has an electrically operated flap. When the APU is off, the flap is closed. Before the APU can start, that flap must open so that outside air can reach the compressor inlet. The starter is electric and the E C B controls it. It will engage only when three conditions are all met: the air intake flap is fully open, the MASTER switch is on, and the START pushbutton is on. That is why there is a short pause after you press START on a cold aircraft: the E C B is waiting for the flap. The flap matters while the APU runs, too. If it closes, the APU shuts down automatically, because it would be starved of air.
Fuel system
Fuel for the APU The left fuel feed line supplies the APU Pressure normally comes from the tank pumps No pressure (batteries only or pumps off ): the APU FUEL PUMP starts automatically The ECB controls the fuel flow Low APU fuel pressure: FUEL LO PR in amber on the APU page left fuel feed line APU FUEL PUMP automatic fuel isolation (LP) valve ECB meters fuel Pump starts when pressure is missing: batteries only, or tank pumps off FUEL LO PR (amber) on the APU page
Chapter 30 · Auxiliary Power Unit
7
e-books by eatpl.in · © 2026 · Do not copy or distribute
The APU takes its fuel from the left fuel feed line, which runs aft along the fuselage to the tail. Normally the tank pumps give it all the pressure it needs. But on a cold aircraft running on batteries only, or with the tank pumps switched off, there is no pressure in the line. In that case the APU fuel pump starts automatically, and the APU can still start. From there, the E C B controls the fuel flow; the crew never meters APU fuel. If the APU fuel pressure becomes low, the APU page shows FUEL LO PR in amber. In the fuel lesson we saw that this pump normally runs from the AC essential shed bus, and from the static inverter bus if that bus fails.
Oil and IGVs
Oil system and inlet guide vanes The APU has an integral, independent oil system for lubrication and cooling The inlet guide vanes (IGVs) control the bleed air flow An actuator powered by fuel pressure moves the IGVs The ECB drives the actuator according to the aircraft's demand IGV failure and several oil problems cause an automatic shutdown Inlet guide vanes Actuator powered by fuel pressure ECB positions the IGVs for the bleed demand Oil system Integral and independent lubrication and cooling Low oil level is checked on the ground with the APU stopped
Chapter 30 · Auxiliary Power Unit
8
e-books by eatpl.in · © 2026 · Do not copy or distribute
Two smaller systems complete the engine. First, oil. The APU has its own integral and independent lubrication system, which both lubricates and cools it, completely separate from the main engines. On the ground with the APU stopped, the E C B checks the oil level and warns of a low level, which we will see on the APU page. Second, the inlet guide vanes, or I G Vs. These vanes control how much bleed air the APU delivers. Their actuator is powered by fuel pressure, which is a neat use of a fluid that is already there, and the E C B positions it in response to what the aircraft is asking for. An I G V failure, like several oil faults, leads to an automatic shutdown.
Air bleed system
Bleed air and APU speed The air bleed system is fully automatic The ECB normally holds the APU at 100 % speed Exception: air conditioning demand with ambient temperature between −18 °C and 35 °C : 99 % Colder than −18 °C or hotter than 35 °C: back to 100 % The APU BLEED pb that opens the valve is covered in the pneumatic lesson What speed will the ECB set? case OAT A/C demand N Packs on APU bleed +20 °C yes 99 % Hot day, packs on APU bleed +40 °C yes 100 % Very cold day, packs on APU bleed -25 °C yes 100 % Main engine start +20 °C no 100 % 99 % only for air conditioning between −18 °C and 35 °C everything else: 100 %
Chapter 30 · Auxiliary Power Unit
9
e-books by eatpl.in · © 2026 · Do not copy or distribute
The air bleed system is fully automatic; the E C B runs it. Normally the E C B sets the APU speed to one hundred per cent. There is one exception. When the bleed demand is for air conditioning, and the ambient temperature is between minus eighteen and plus thirty five degrees, the E C B sets ninety nine per cent instead. Outside that band, colder than minus eighteen or hotter than thirty five, it goes back to one hundred. Let us check the table. Packs on APU bleed on a twenty degree day: ninety nine per cent. The same on a forty degree day: one hundred. On a minus twenty five degree day: one hundred. And a main engine start, which is not an air conditioning demand: one hundred per cent. So seeing ninety nine on a mild day is perfectly normal.
APU panel
The APU panel: MASTER SW and START APU MASTER SW START FAULT ON AVAIL ON APU off all lights out APU MASTER SW START FAULT ON AVAIL ON MASTER SW ON flap opens, ECB test APU MASTER SW START FAULT ON AVAIL ON START ON start sequence APU MASTER SW START FAULT ON AVAIL ON AVAIL N above 95 % APU MASTER SW START FAULT ON AVAIL ON FAULT automatic shutdown MASTER SW: FAULT amber, ON blue. START: AVAIL green, ON blue.
Chapter 30 · Auxiliary Power Unit
10
e-books by eatpl.in · © 2026 · Do not copy or distribute
Now into the cockpit. The APU panel on the overhead has just two pushbuttons. The upper one is the MASTER switch, with an amber FAULT light and a blue ON light. The lower one is the START pushbutton, with a green AVAIL light and a blue ON light. Follow the states from left to right. With the APU off, all lights are out. Press the MASTER switch and its blue ON light comes on: the APU system is powered and preparing. Press START and its blue ON comes on while the start sequence runs. When the APU reaches the right speed, START ON goes out and green AVAIL comes on: the APU can now supply bleed air and electrical power. And if the APU shuts down automatically, the amber FAULT light comes on in the MASTER switch.
MASTER SW pb
MASTER SW ON: getting ready Controls electric power to the APU and its protections , and the start and shutdown sequences ON (blue): power to the APU system; the ECB runs a power-up test The air intake flap opens and the fuel isolation valve opens If no fuel tank pump is running, the APU fuel pump runs The APU page appears on the ECAM if there is ground power or main generator power APU MASTER SW START FAULT ON AVAIL ON 1 Power to the APU system; the ECB runs a power-up test 2 Air intake flap opens 3 Fuel isolation valve opens 4 APU fuel pump runs if no tank pump is running 5 APU page on the ECAM (with ground or main generator power) MASTER SW OFF while running = manual shutdown ON and AVAIL go out, cooling run if bleed was used, flap closes at 7 %
Chapter 30 · Auxiliary Power Unit
11
e-books by eatpl.in · © 2026 · Do not copy or distribute
The MASTER switch controls the electrical power supply for the APU and its protections, and it also controls the starting and shutdown sequences. Pressing it on starts the preparations. Electrical power goes to the APU system, and the E C B performs a power up test of itself. The air intake flap opens. The APU fuel isolation valve opens. If no fuel tank pump is running, the APU fuel pump operates, so there will be fuel pressure for the start. And if the aircraft has ground power or main generator power, the APU system page appears on the ECAM so you can watch what follows. Note that on batteries alone the page does not appear automatically. The APU is now ready, but it is not turning yet. That needs the START button.
START pb
The start sequence, step by step 0 20 40 60 80 100 N % time (illustrative, not to scale) AVAIL above 95 % START pb flap opening flap fully open starter on +1.5 s ignition on N 60 % starter and ignition off N 95 % + 2 s START ON out, AVAIL on +10 s APU page clears Times between the steps depend on the APU and the conditions; the 1.5 s, 2 s and 10 s figures are fixed by the logic.
Chapter 30 · Auxiliary Power Unit
12
e-books by eatpl.in · © 2026 · Do not copy or distribute
Let us run a start. You press START and its blue ON comes on. First, the E C B waits until the air intake flap is completely open. Then the starter is energised and the APU begins to turn. One point five seconds after the starter is energised, the ignition comes on, fuel lights up and the exhaust gas temperature rises. The APU accelerates, and at sixty per cent speed the starter is de-energised and the ignition switches off, because the APU can now sustain itself. Two seconds after the speed reaches ninety five per cent, or straight away above ninety nine point five, the ON light goes out and AVAIL comes on in green. The APU can now supply bleed air and electrical power. Ten seconds later, the APU page disappears from the ECAM.
AVAIL
When is the APU available? START pb AVAIL light (green): N above 95 % APU page AVAIL (green): N above 95 % START ON goes out 2 s after N 95 % , or when N is above 99.5 % E/WD memo APU AVAIL (green): N above 99.5 % , or 2 s after 95 % , depending on configuration From AVAIL, the APU can supply bleed air and electrical power APU MASTER SW START FAULT ON AVAIL ON APU AVAIL APU page APU AVAIL memo on the E/WD AVAIL: N above 95 % START ON out: 2 s after 95 %, or above 99.5 % Memo: above 99.5 %, or 2 s after 95 % (by configuration)
Chapter 30 · Auxiliary Power Unit
13
e-books by eatpl.in · © 2026 · Do not copy or distribute
Availability is shown in three places, so let us be precise. The green AVAIL light in the START button, and the green AVAIL legend on the APU page, come on when the APU speed is above ninety five per cent. The blue ON light in the START button goes out two seconds after the speed reaches ninety five per cent, or as soon as the speed is above ninety nine point five per cent. On the engine and warning display, the green APU AVAIL memo appears when the speed is above ninety nine point five per cent, or two seconds after it passes ninety five per cent, depending on the aircraft configuration. From that moment the APU can supply bleed air and electrical power to the aircraft systems, and the crew can, for example, start the main engines with APU bleed.
Shutdown
Manual shutdown and the cooling run Routine shutdown: press the MASTER SW OFF The MASTER SW ON and START AVAIL lights go out If APU bleed air was used, the APU keeps running 60 to 120 s to cool At 7 % N the air inlet flap closes Flap not fully closed 3 min after MASTER SW OFF: FLAP OPEN advisory Manual shutdown 1 MASTER SW pressed OFF MASTER ON and START AVAIL go out 2 APU bleed was in use? keeps running 60 to 120 s to cool 3 N falls at 7 % the air inlet flap closes 4 Flap not closed 3 min after OFF FLAP OPEN advisory on the APU page
Chapter 30 · Auxiliary Power Unit
14
e-books by eatpl.in · © 2026 · Do not copy or distribute
The flight crew uses the APU panel for a routine shutdown: simply press the MASTER switch off. The ON light in the MASTER switch and the AVAIL light in the START button go out at once. But do not be surprised if the APU keeps running. If the aircraft was using APU bleed air, the APU continues for a cooling period of sixty to one hundred and twenty seconds before it stops, which protects it from thermal stress. Then the speed winds down, and at seven per cent the air inlet flap closes. The E C B keeps an eye on that flap: if it is not fully closed three minutes after the MASTER switch was turned off, a FLAP OPEN advisory appears on the APU page.
Automatic shutdown
When the ECB shuts the APU down The MASTER SW FAULT light comes on and the ECAM shows APU AUTO (EMER) SHUT DOWN (the light depends on the ECB version).
Group Automatic shutdown cases Fire Fire (on the ground only ) Air and intake Air inlet flap closed · reverse flow · inlet overheat Speed Overspeed · underspeed · no speed · no acceleration · slow start · loss of overspeed protection Temperature and flame EGT overtemperature · no flame · loss of EGT thermocouples Oil Low oil pressure · high oil temperature · oil system shutdown · clogged oil filter Electrical and control DC power lost (BAT OFF on batteries only) · overcurrent · sensor, IGV or ECB failure
Chapter 30 · Auxiliary Power Unit
15
e-books by eatpl.in · © 2026 · Do not copy or distribute
The E C B protects the APU by shutting it down automatically in a long list of cases, which we have grouped to make them easier to remember. Fire, but only on the ground. The air system: the air inlet flap closing, reverse flow, or an inlet overheat. Speed: overspeed, underspeed, no speed, no acceleration, a slow start, or loss of the overspeed protection. Temperature and flame: E G T overtemperature, no flame, or loss of the E G T thermocouples. Oil: low oil pressure, high oil temperature, an oil system shutdown or a clogged oil filter. And electrics and control: loss of DC power, which includes selecting the batteries off when the aircraft is on batteries only, overcurrent, or a sensor, I G V or E C B failure. The FAULT light comes on, with an ECAM caution.
Emergency shutdown
Emergency shutdown, inside and outside Routine shutdown: the MASTER SW Emergency, flight crew: push the APU FIRE pb (handle) Emergency, ground crew: the APU SHUT OFF pb It is on the external power (interphone) panel under the nose fuselage The fire protection itself is covered in the fire protection lesson Flight crew Ground crew APU FIRE APU FIRE APU FIRE pb (handle) external power panel SHUT APU SHUT OFF pb, under the nose Routine stop: MASTER SW on the APU panel Emergency stop: APU FIRE pb in the cockpit or APU SHUT OFF pb on the panel under the nose
Chapter 30 · Auxiliary Power Unit
16
e-books by eatpl.in · © 2026 · Do not copy or distribute
There are two ways to stop the APU in an emergency, one inside and one outside the aircraft. In the cockpit, the flight crew pushes the APU FIRE pushbutton, which shuts the APU down as part of isolating it. On the ground, the ground crew can push the APU SHUT OFF pushbutton, which is on the interphone and external power panel under the nose fuselage, next to the nose gear. That gives someone outside the aircraft a way to stop the APU, for example if they see a fire or a fuel leak at the tail. Watch the APU stop when the button is pressed. For a routine stop, though, always use the MASTER switch, so the APU gets its proper cooling run. We cover the fire extinguishing itself in the fire protection lesson.
Ground safety
APU fire with nobody in the cockpit On the ground the APU may run without cockpit crew supervision APU fire: fire warnings in the cockpit and a horn in the nose gear bay The AVAIL light goes out; the MASTER SW FAULT light comes on The APU shuts down automatically The APU fire extinguisher discharges automatically APU fire on the ground (unattended running allowed) 1 APU fire warnings in the cockpit 2 Horn sounds in the nose gear bay 3 AVAIL light goes out 4 FAULT light on the MASTER SW 5 APU shuts down 6 APU fire extinguisher discharges
Chapter 30 · Auxiliary Power Unit
17
e-books by eatpl.in · © 2026 · Do not copy or distribute
On the ground, the APU is allowed to run without anyone in the cockpit, for example while the aircraft is being cleaned and cooled during a turnaround. So what happens if the APU catches fire then? The system protects itself. The APU fire warnings operate in the cockpit as usual. A horn sounds in the nose gear bay, to alert the ground crew outside. The AVAIL light goes out and the FAULT light in the MASTER switch comes on. The APU shuts down automatically, and the APU fire extinguisher discharges automatically. Compare that with flight, where a fire is not an automatic shutdown case and the crew carries out the procedure. Remember: fire is an automatic shutdown on the ground only.
ECAM APU page
The ECAM APU page APU AVAIL APU GEN 26 % 115 V 400 HZ BLEED 35 PSI 0 10 N % 100 3 10 EGT °C 440 FUEL LO PR FLAP OPEN LOW OIL LEVEL 1 AVAIL: N above 95 % 2 APU bleed valve position 3 APU bleed pressure 4 APU GEN line contactor 5 APU GEN load, voltage, frequency 6 FUEL LO PR (amber) 7 FLAP OPEN 8 APU speed N 9 APU EGT 10 LOW OIL LEVEL advisory 1 2 3 4 5 6 7 8 9 10 FUEL LO PR and LOW OIL LEVEL are shown here together only for learning.
Chapter 30 · Auxiliary Power Unit
18
e-books by eatpl.in · © 2026 · Do not copy or distribute
Here is the ECAM APU page. At the top is AVAIL in green, once the speed is above ninety five per cent. On the left is the APU generator box, with a small green triangle above it when the APU generator line contactor is closed, and inside it the generator load, voltage and frequency, which are the same figures as on the ELEC page. On the right is the APU bleed valve symbol and below it a box with the relative bleed pressure in P S I. The lower half has the two dials, APU speed N and exhaust gas temperature, each with a digital readout. On the right side three messages can appear: FUEL LO PR, FLAP OPEN and LOW OIL LEVEL. In real life you would rarely see all of them at once.
APU page: N and EGT
N and EGT: green, amber, red N : green; amber at or above 102 % ; red at or above 107 % EGT : green; amber at or above EGT MAX − 33 °C ; red at EGT MAX, where automatic shutdown beginsThe ECB computes EGT MAX : a function of N during start, of ambient temperature when running Start: 1 090 °C below 35 000 ft, 1 120 °C above Running: 675 °C , so amber from 642 °C APU N 0 50 95 102 107 green AVAIL APU EGT (running, EGT MAX 675 °C) 0 642 675 green amber from EGT MAX − 33 °C · red at EGT MAX: auto shutdown EGT MAX is computed by the ECB case EGT MAX amber from Start, below 35 000 ft 1 090 °C 1 057 °C Start, above 35 000 ft 1 120 °C 1 087 °C APU running 675 °C 642 °C
Chapter 30 · Auxiliary Power Unit
19
e-books by eatpl.in · © 2026 · Do not copy or distribute
The two dials change colour as limits approach. APU speed is green normally, amber at or above one hundred and two per cent, and red at or above one hundred and seven. Exhaust gas temperature is green normally, amber when it is within thirty three degrees of the maximum, and red at the maximum, where the automatic shutdown begins. The E C B calculates that maximum and sends it to the ECAM. During the start it depends on the speed, and with the APU running it depends on the ambient temperature. The highest values are one thousand and ninety degrees for a start below thirty five thousand feet, one thousand one hundred and twenty above it, and six hundred and seventy five with the APU running. So with a running maximum of six hundred and seventy five, amber starts at six hundred and forty two.
Worked example
Reading an amber APU page APU AVAIL APU GEN 30 % 115 V 400 HZ BLEED 35 PSI 0 10 N % 100 3 10 EGT °C 450 FLAP OPEN APU AVAIL APU GEN 30 % 115 V 400 HZ BLEED 35 PSI 0 10 N % 103 3 10 EGT °C 655 FLAP OPEN Normal: N 100 %, EGT 450 °C, all green N 103 % and EGT 655 °C: both amber 675 − 33 = 642 °C: 655 °C is amber. 103 % is at or above 102 %: amber. Neither is yet red.
Chapter 30 · Auxiliary Power Unit
20
e-books by eatpl.in · © 2026 · Do not copy or distribute
Let us read two APU pages. On the left, a normal running APU: speed one hundred per cent and E G T four hundred and fifty degrees, both green, with the generator and bleed figures in green too. On the right, the speed reads one hundred and three per cent, which is at or above one hundred and two, so it is amber. The E G T reads six hundred and fifty five degrees. With the APU running, the maximum is six hundred and seventy five, so the amber threshold is six hundred and seventy five minus thirty three, which is six hundred and forty two. Six hundred and fifty five is above that, so it is amber too. Neither has reached red, so no automatic shutdown yet, but the APU is clearly working hard and deserves attention.
APU page: bleed and generator
Bleed valve, bleed pressure and generator Bleed valve in line green : not closed · cross line green : closed Cross line amber : closed although APU BLEED is ON · XX amber : status unavailableBleed pressure in green ; amber XX if ADIRS 1 or 2 is lost or ECB data invalid Green triangle: APU GEN line contactor closed Generator load, voltage, frequency: as on the ELEC page APU bleed valve symbol in line green valve not closed cross line green valve closed cross line amber closed, APU BLEED ON XX XX amber status not available Bleed pressure box BLEED 35 PSI BLEED XX PSI relative pressure, green ADIRS 1 or 2 lost, or no ECB data APU GEN APU GEN 30 % 115 V 400 HZ green triangle: line contactor closed load, voltage, frequency: same as on the ELEC page
Chapter 30 · Auxiliary Power Unit
21
e-books by eatpl.in · © 2026 · Do not copy or distribute
Now the upper half of the page in detail. The APU bleed valve symbol is in line green when the valve is not closed, and cross line green when it is closed and that is expected. A cross line in amber means the valve is closed although the APU BLEED pushbutton is on, so the air you asked for is not coming. An amber X X means the valve status, or the APU BLEED pushbutton status, is not available. The box below shows the relative bleed pressure in green. It shows an amber X X if A D I R S one or two is not available or is switched off, or if the E C B data is invalid. On the left, the green triangle shows that the APU generator line contactor is closed, and the generator parameters are identical to those on the ELEC page.
APU page: messages
FUEL LO PR, FLAP OPEN, LOW OIL LEVEL FUEL LO PR (amber): APU fuel pressure lowFLAP OPEN (green): air intake flap fully openFLAP OPEN becomes an advisory if the flap is not fully closed 3 min after MASTER SW OFF LOW OIL LEVEL : advisory when the ECB detects low oil on the ground with the APU not running Start-up: MASTER SW ON with main or ground power brings the page up APU APU GEN BLEED XX PSI 0 10 N % 0 3 10 EGT °C 20 FLAP OPEN APU AVAIL APU GEN 26 % 115 V 400 HZ BLEED 35 PSI 0 10 N % 100 3 10 EGT °C 440 FUEL LO PR FLAP OPEN MASTER SW ON FUEL LO PR (amber) FLAP OPEN: green when the intake flap is fully open Advisory if the flap is not closed 3 min after MASTER OFF LOW OIL LEVEL: advisory, on the ground, APU not running FUEL LO PR: APU fuel pressure low
Chapter 30 · Auxiliary Power Unit
22
e-books by eatpl.in · © 2026 · Do not copy or distribute
The right side of the page carries three messages. FUEL LO PR, in amber, means the APU fuel pressure is low, for example if the feed pressure has been lost. FLAP OPEN, in green, means the air intake flap is fully open, which is what you expect to see shortly after selecting the MASTER switch on. The same legend becomes an advisory if the flap is not fully closed three minutes after the MASTER switch was turned off, which suggests the flap has stuck. And LOW OIL LEVEL is an advisory that the E C B gives when it detects a low APU oil level while the aircraft is on the ground and the APU is not running. It is then a job for maintenance before the next flight.
Putting it together
A day in the life of the APU Phase What the APU does What the crew sees Cold aircraft, batteries only MASTER SW ON: flap opens, APU fuel pump runs; START MASTER ON, START ON, then AVAIL (no APU page on batteries) Turnaround Electrical power and bleed air for the packs; may run unattended AVAIL; N 99 % on a mild day with the packs on APU bleed Engine start Bleed air to start the engines APU bleed valve in line green Take-off (performance) Bleed air for air conditioning Engines need not supply the packs In flight, if needed Backs up electrics and air conditioning; can start the engines Start permitted throughout the normal envelope After shutdown Cooling run 60 to 120 s if bleed was used; flap closes at 7 % ON and AVAIL out at once; FLAP OPEN advisory if not closed in 3 min
Chapter 30 · Auxiliary Power Unit
23
e-books by eatpl.in · © 2026 · Do not copy or distribute
Let us put the whole lesson into one day. On a cold aircraft with only the batteries, you press the MASTER switch: the flap opens and the APU fuel pump runs because no tank pump is on. Then START, and AVAIL a little later. During the turnaround, the APU powers the aircraft and feeds the packs, and it may run with nobody in the cockpit; on a mild day you will see ninety nine per cent. For engine start, its bleed air turns the main engines. On some take-offs, APU bleed feeds the air conditioning so the engines give their full performance. In flight it stays available as a back-up and can even start an engine. And after the final shutdown, it runs on to cool if bleed was used, and its flap closes at seven per cent.
Summary
The APU in one page Role Bleed air and electrical power; ground, take-off, in-flight back-up; starts on batteries, network or ground power.
Engine and ECB Single-shaft gas turbine; full-authority ECB runs start, monitoring, shutdown and auto shutdown.
Systems Electric intake flap; starter needs flap open + MASTER + START; left feed line and APU fuel pump; own oil; fuel-powered IGVs.
Start Flap open, starter, ignition +1.5 s, off at 60 %, AVAIL above 95 %, page clears 10 s later; 99 % for A/C between −18 and 35 °C.
Stop MASTER OFF; cooling 60–120 s if bleed used; flap closes at 7 %; FAULT on auto shutdown; APU FIRE or APU SHUT OFF for emergencies.
APU page N amber 102 %, red 107 %; EGT amber at MAX − 33, red at MAX (675 °C running); FUEL LO PR, FLAP OPEN, LOW OIL LEVEL.
Chapter 30 · Auxiliary Power Unit
24
e-books by eatpl.in · © 2026 · Do not copy or distribute
Let us wrap up. The APU is a self-contained single shaft gas turbine that supplies bleed air and electrical power, on the ground, during take-off and as a back-up in flight. A full authority E C B runs everything. The starter needs the flap fully open with the MASTER and START buttons on. Fuel comes from the left feed line, with an automatic APU pump when there is no pressure. In the start, ignition comes one and a half seconds after the starter, the starter drops out at sixty per cent, and AVAIL comes on above ninety five. After MASTER off, it may cool for up to two minutes, and its flap closes at seven per cent. Learn the automatic shutdowns, fire on the ground only, and the N and E G T colours. That completes the APU.