A320 Aircraft Systems · Chapter 12
Electrical Distribution, Emergency Configuration and ELEC Panel How power reaches every bus bar, how the system reconfigures after failures, the emergency electrical configuration, and the complete ELEC panel and ECAM ELEC page.
DC BUS 1 DC BUS 2 AC BUS 1 AC BUS 2 AC ESS BUS COMMERCIAL OFF BAT 1 28.1 V 1 BAT 2 FAULT OFF FAULT OFF BAT 2 28.2 V AC ESS FEED FAULT ALTN GALLEY FAULT OFF A U T O IDG 1 FAULT IDG 2 FAULT GEN 1 FAULT OFF APU GEN FAULT OFF GEN 2 FAULT OFF EXT PWR AVAIL ON BUS TIE OFF A U T O E L E C E L E C ELEC DC BAT DC 1 DC 2 DC ESS AC 1 AC 2 AC ESS BAT 1 28 V 0 A BAT 2 28 V 0 A TR 1 0 V 0 A TR 2 0 V 0 A ESS TR 28 V 130 A EMER GEN 116 V 400 HZ GEN 1 OFF GEN 2 OFF APU GEN IDG 1 40 °C 43 °C IDG 2 TAT -21 °C SAT -42 °C 14 H 05 GW 64200 KG © 2026 eatpl.in. For the personal study of eatpl.in students only. Do not copy or distribute.
e-books by eatpl.in · © 2026 · Do not copy or distribute
Welcome back to the A320 electrical system. In the last lesson we met the sources. Now we follow the power from those sources to every bus bar, and see how the network reconfigures itself when something fails. We will go through the whole ELEC overhead panel and read the ECAM ELEC page bar by bar. Then come the failures that type-rating examiners love: a generator, an AC bus, a transformer rectifier, and finally the big one, the emergency electrical configuration, where the RAT and the emergency generator keep the essential buses alive, and the batteries take over at the very end of the landing roll. We finish with the smoke configuration, the maintenance bus and circuit breakers.
Electrical distribution
Our route through ATA 24 distribution DC BUS 1 DC BUS 2 AC BUS 1 AC BUS 2 AC ESS BUS COMMERCIAL OFF BAT 1 28.1 V 1 BAT 2 FAULT OFF FAULT OFF BAT 2 28.2 V AC ESS FEED FAULT ALTN GALLEY FAULT OFF A U T O IDG 1 FAULT IDG 2 FAULT GEN 1 FAULT OFF APU GEN FAULT OFF GEN 2 FAULT OFF EXT PWR AVAIL ON BUS TIE OFF A U T O E L E C E L E C ELEC DC BAT DC 1 DC 2 DC ESS AC 1 AC 2 AC ESS BAT 1 28 V 0 A BAT 2 28 V 0 A TR 1 28 V 150 A TR 2 28 V 150 A ESS TR EMER GEN GEN 1 26 % 116 V 400 HZ GEN 2 26 % 116 V 400 HZ APU GEN IDG 1 110 °C 115 °C IDG 2 TAT -21 °C SAT -42 °C 14 H 05 GW 64200 KG Normal distribution AC and DC bus bars, essential and shed buses, the ELEC page.
ELEC panel BUS TIE, AC ESS FEED, GALLEY, COMMERCIAL and the rest.
Failures One generator, AC BUS 1, one or both TRs.
Emergency EMER GEN, batteries only, landing roll, smoke config, MAINT BUS, C/Bs.
Chapter 12 · Electrical Distribution, Emergency Configuration and ELEC Panel
2
e-books by eatpl.in · © 2026 · Do not copy or distribute
Here is the plan for this lesson. We start with normal distribution: the AC bus bars, the DC bus bars, the essential and shed buses, and how all of that appears on the ECAM ELEC page, shown on the right. Then we walk across the ELEC panel on the overhead, with the pushbuttons we have not met yet: BUS TIE, AC ESS FEED, GALLEY and COMMERCIAL. Third come the classic single failures: a generator, AC bus one, and the transformer rectifiers. And finally the emergency side: the emergency electrical configuration with the RAT, battery-only operation and the landing roll, then the smoke configuration, the maintenance bus switch and the circuit breakers.
Normal distribution
The A320 electrical network in normal flight DC BAT BUS HOT BUS 1 HOT BUS 2 DC BUS 1 DC ESS BUS DC ESS SHED DC BUS 2 AC STAT INV AC ESS SHED AC ESS BUS AC BUS 1 AC BUS 2 GEN 1 APU GEN GEN 2 EXT PWR EMER GEN TR 1 TR 2 ESS TR STAT INV BAT 1 BAT 2 AC powered DC powered not powered open contactor Normal flight: each generator feeds its own side, AC BUS 1 feeds the essential AC side, TR 1 the essential DC side. The batteries are only on their hot buses.
Chapter 12 · Electrical Distribution, Emergency Configuration and ELEC Panel
3
e-books by eatpl.in · © 2026 · Do not copy or distribute
This is the whole network in normal flight; take your time with it, because every failure later is a change to this picture. At the bottom, generator one feeds AC bus one and generator two feeds AC bus two, with both bus tie contactors open. AC bus one also feeds the AC essential bus, and from it the AC essential shed bus. Each AC bus feeds its transformer rectifier: T R one supplies DC bus one, and through it the DC battery bus and the DC essential bus with its shed part. T R two supplies DC bus two. The batteries are connected only to their hot buses, with their contactors open. And notice what is idle: the essential T R, the emergency generator and the static inverter. They wait for a failure.
Normal distribution
AC distribution Each engine GEN feeds its AC BUS 1 (2) through its line contactor (GLC 1, GLC 2) AC BUS 1 normally feeds the AC ESS BUS through a contactorThe AC ESS SHED bus hangs off the AC ESS; it is shed on batteries AC STAT INV bus: fed only by the static inverter, on batteriesOn the ground, the APU GEN or external power can feed the complete system ELEC DC BAT DC 1 DC 2 DC ESS AC 1 AC 2 AC ESS BAT 1 28 V 0 A BAT 2 28 V 0 A TR 1 28 V 150 A TR 2 28 V 150 A ESS TR EMER GEN GEN 1 26 % 116 V 400 HZ GEN 2 26 % 116 V 400 HZ APU GEN IDG 1 110 °C 115 °C IDG 2 TAT -21 °C SAT -42 °C 14 H 05 GW 64200 KG
Chapter 12 · Electrical Distribution, Emergency Configuration and ELEC Panel
4
e-books by eatpl.in · © 2026 · Do not copy or distribute
Let us look at the AC side on its own. In flight, each engine generator supplies its own AC bus through its generator line contactor: generator one, AC bus one; generator two, AC bus two. AC bus one normally also supplies the AC essential bus, through a contactor that the AC ESS FEED button controls, as we will see. Part of the essential AC load sits on a separate bar, the AC essential shed bus, which can be dropped when only batteries are available. A small AC static inverter bus exists for the static inverter, and is used only when the batteries are in charge. On the ground, the APU generator or external power can feed the whole system. On the ELEC page here, follow the green lines: generator to bus, AC one across to AC ESS.
Normal distribution
DC distribution TR 1 feeds DC BUS 1 , the DC BAT BUS and the DC ESS BUS TR 2 feeds DC BUS 2 DC ESS SHED hangs off the DC ESS; shed on batteriesHOT BUS 1 and 2 : always on the batteriesBatteries join the DC BAT BUS only to charge ; TR Ent feeds the DC BUS Ent (some aircraft) DC BAT BUS DC BUS 1 DC ESS BUS DC BUS 2 DC ESS SHED TR 1 TR 2 from AC BUS 1 from AC BUS 2 ESS TR idle BAT 1 BAT 2 battery contactors open (charged) TR 1: DC BUS 1, DC BAT BUS, DC ESS BUS TR 2: DC BUS 2 Hot buses: always on the batteries TR Ent and DC BUS Ent on some aircraft
Chapter 12 · Electrical Distribution, Emergency Configuration and ELEC Panel
5
e-books by eatpl.in · © 2026 · Do not copy or distribute
Now the DC side. T R one is the busy one: it supplies DC bus one, and through it the DC battery bus and the DC essential bus. T R two supplies DC bus two alone. The DC essential bus has its own shed part, the DC essential shed bus, which is dropped when only batteries are left. The two hot buses are wired straight to the batteries, so equipment on them stays live whatever happens, even with every switch off. The batteries themselves join the DC battery bus only when their charge limiters decide they need charging. And on aircraft with in-flight entertainment, a fourth T R feeds the entertainment DC bus, which needs two generators in flight. In the diagram, look at the top half: purple lines are DC.
ECAM ELEC page
Reading the ELEC page ELEC DC BAT DC 1 DC 2 DC ESS AC 1 AC 2 AC ESS BAT 1 28 V 0 A BAT 2 28 V 0 A TR 1 28 V 150 A TR 2 28 V 150 A ESS TR EMER GEN GEN 1 26 % 116 V 400 HZ GEN 2 26 % 116 V 400 HZ APU GEN IDG 1 110 °C 115 °C IDG 2 TAT -21 °C SAT -42 °C 14 H 05 GW 64200 KG 1 Batteries: voltage, current, charge arrow 2 DC BAT, DC 1, DC 2, DC ESS bus bars 3 TR 1 and TR 2: voltage and current 4 ESS TR and EMER GEN: name only when idle 5 AC 1, AC ESS, AC 2 bus bars 6 Generators: load, voltage, frequency 7 APU GEN and EXT PWR boxes 8 IDG temperature, LO PR, DISC 9 GALLEY SHED legend (when shed) 1 2 3 4 5 6 7 8 9
Chapter 12 · Electrical Distribution, Emergency Configuration and ELEC Panel
6
e-books by eatpl.in · © 2026 · Do not copy or distribute
Here is the ECAM ELEC page in normal flight, laid out like the network. At the top are the two batteries either side of the DC battery bar. Below them, the DC bars: DC one, DC essential and DC two. Then the transformer rectifiers, T R one on the left, T R two on the right, and in the middle the essential T R and the emergency generator, shown only by their names while they are idle. Next row, the AC bars: AC one, AC essential and AC two. At the bottom, the two generator boxes, the APU generator and external power positions, and the I D G lines. A GALLEY SHED legend can appear at the bottom centre. Read the page top to bottom, and follow the green lines: they show where power is actually flowing.
ECAM ELEC page
Bus bars, SHED, GALLEY SHED and the memo Bus bar label green : powered; amber : not powered SHED (amber) under AC ESS or DC ESS: its shed bus is shed GALLEY SHED : GALLEY pb OFF, or main galleys shed (one generator in flight; one engine GEN on the ground)Memo EMER GEN (green): the emergency generator is running Remember: DC BAT is also amber at 25 V or less Bus bar indications AC 1 green: bus bar powered AC 1 amber: bus bar not powered AC ESS SHED SHED: the AC (or DC) SHED ESS bus is shed GALLEY SHED (white, bottom centre) GALLEY pb OFF, or main galleys shed: in flight: only one generator operating on the ground: one engine generator only Memo EMER GEN green: the emergency generator is running
Chapter 12 · Electrical Distribution, Emergency Configuration and ELEC Panel
7
e-books by eatpl.in · © 2026 · Do not copy or distribute
Each bus bar on the page is a grey bar with its name. Green means powered; amber means the bar is not powered. Under the AC essential and DC essential bars, an amber SHED legend appears when the corresponding shed bus has been shed, which happens when the batteries are carrying the essential network. At the bottom centre, a white GALLEY SHED legend appears when the GALLEY button is off, or when the main galleys have been shed automatically: in flight because only one generator is operating, on the ground because only one engine generator is supplying. And on the engine and warning display, a green EMER GEN memo appears whenever the emergency generator is running. Remember also from last time that the DC battery bar turns amber at twenty five volts or less.
ELEC panel
The ELEC overhead panel DC BUS 1 DC BUS 2 AC BUS 1 AC BUS 2 AC ESS BUS COMMERCIAL OFF BAT 1 28.1 V 1 BAT 2 FAULT OFF FAULT OFF BAT 2 28.2 V AC ESS FEED FAULT ALTN GALLEY FAULT OFF A U T O IDG 1 FAULT IDG 2 FAULT GEN 1 FAULT OFF APU GEN FAULT OFF GEN 2 FAULT OFF EXT PWR AVAIL ON BUS TIE OFF A U T O E L E C E L E C 1 2 3 4 5 6 7 8 9 10 1 COMMERCIAL 2 BAT voltmeters 3 BAT 1, BAT 2 4 AC ESS FEED 5 GALLEY 6 IDG 1 (2) 7 GEN 1 (2) 8 APU GEN 9 BUS TIE 10 EXT PWR
Chapter 12 · Electrical Distribution, Emergency Configuration and ELEC Panel
8
e-books by eatpl.in · © 2026 · Do not copy or distribute
Here is the complete ELEC panel on the overhead, drawn as a mimic of the network. Across the top: the COMMERCIAL button, fitted on some aircraft, the two battery voltmeters with the BAT one and BAT two buttons between them, and AC ESS FEED. The middle row shows the mimic of AC bus one, the AC essential bus and AC bus two. The GALLEY button sits on the left. Along the bottom, from the left: I D G one under its red guard, generator one, the APU generator, the BUS TIE button in the middle of the tie line, external power, generator two and I D G two. As usual on the A320, it is a dark cockpit: in normal flight every light is out. We met the source buttons last time; now let us do the remaining four.
ELEC panel
BUS TIE: one or both contactors? AUTO : the bus tie contactors open or close by themselves to keep AC BUS 1 and 2 poweredOne closed : one engine GEN feeds its own bus, the APU GEN or EXT PWR feeds the other sideBoth closed : single engine GEN , or APU GEN or EXT PWR aloneBoth open : two engine generatorsOFF (white): both bus tie contactors openAC 1 AC 2 G1 APU G2 Two engine GENs both BTCs open AC 1 AC 2 G1 APU G2 GEN 1 lost, APU on one BTC closed AC 1 AC 2 G1 APU G2 GEN 1 lost, no APU both BTCs closed OFF BUS TIE: AUTO AUTO: the contactors open and close by themselves to keep AC BUS 1 and 2 powered One closed: one engine GEN on its own side, APU GEN or EXT PWR on the other side Both closed: single engine GEN, or APU GEN or EXT PWR alone OFF: both bus tie contactors open
Chapter 12 · Electrical Distribution, Emergency Configuration and ELEC Panel
9
e-books by eatpl.in · © 2026 · Do not copy or distribute
The BUS TIE button normally stays at AUTO, and the two bus tie contactors then look after themselves, always with one aim: keep AC bus one and AC bus two powered, from one source each. Watch the scene. With both engine generators running, both contactors are open and each generator feeds its own bus. Now generator one fails, and AC bus one goes dead. The APU generator is started and comes on line, and bus tie contactor one closes, so the APU now feeds AC bus one, while generator two still feeds its own side. That is the one-contactor case. If there were no APU, both contactors would close and generator two would carry both buses. Both also close when the APU generator or external power feeds the whole aircraft. Selecting OFF opens both.
Normal (lights out): the AC ESS BUS is fed by AC BUS 1 ALTN (white, selected by hand): fed by AC BUS 2 Amber FAULT : the AC ESS BUS is not powered With auto switching (some aircraft): AC BUS 2 takes over automatically when AC BUS 1 is lost All main generators lost: AC ESS from the EMER GEN , or else the static inverter AC ESS FEED pb FAULT ALTN Normal AC ESS from AC BUS 1 FAULT ALTN ALTN AC ESS from AC BUS 2 FAULT ALTN FAULT AC ESS BUS not powered AC BUS 1 AC BUS 2 AC ESS BUS normal ALTN never both at once On aircraft with AC ESS FEED auto switching, AC BUS 2 takes over the AC ESS BUS by itself when AC BUS 1 is lost. All main generators lost: EMER GEN, or else the static inverter.
Chapter 12 · Electrical Distribution, Emergency Configuration and ELEC Panel
10
e-books by eatpl.in · © 2026 · Do not copy or distribute
The AC ESS FEED button chooses which main AC bus feeds the AC essential bus. In its normal position, all lights out, AC bus one does the job. If the crew presses it, the white ALTN light comes on and AC bus two feeds the essential bus instead. The amber FAULT light tells you the AC essential bus has no power at all, which is the cue for that action on aircraft without automatic switching. Many aircraft now have AC ESS FEED auto switching, which makes the change to AC bus two by itself when AC bus one is lost. And one more point to remember: if every main generator is gone, this button is not involved at all, because the AC essential bus is then supplied automatically by the emergency generator, or by the static inverter if the emergency generator is not available.
ELEC panel
GALLEY and COMMERCIAL AUTO : main and secondary galleys, in-seat power and IFE suppliedAuto shed (main galley, in-seat power, IFE): in flight with only one generator ; on ground with only one engine GEN OFF : all those loads off, and the floor panel heating is shedAmber FAULT : load on any generator above 100 % COMMERCIAL OFF (some aircraft): all commercial loads offGALLEY (or GALY & CAB) pb FAULT OFF AUTO galleys, in-seat power, IFE FAULT OFF OFF all of them off FAULT OFF FAULT a GEN above 100 % Automatic shedding at AUTO (main galley, in-seat power, IFE): in flight: only one generator operating on the ground: only one engine generator (APU GEN or EXT PWR: all galleys) with automatic galley load shedding: the secondary galley too OFF COMMERCIAL pb (some aircraft) ON: cabin and cargo lights, water and toilets, drain mast ice protection, galleys, passenger entertainment, cargo loading (some aircraft) OFF: all commercial loads off
Chapter 12 · Electrical Distribution, Emergency Configuration and ELEC Panel
11
e-books by eatpl.in · © 2026 · Do not copy or distribute
The galleys are the biggest non-essential load, so they have their own button, labelled GALLEY, or GALY and CAB on some aircraft. At AUTO, the main and secondary galleys, the in-seat power supply and the entertainment system are all supplied. They are shed automatically when the network is short of generators: in flight when only one generator is operating, and on the ground when only one engine generator is supplying, although the APU generator or external power can carry all the galleys. On aircraft with automatic galley load shedding, the secondary galley goes too. Selecting OFF removes all of them and the floor panel heating. The amber FAULT light means a generator is loaded above one hundred per cent. Some aircraft also have a COMMERCIAL button that switches off every commercial load in one go.
Failures
Failure of one engine generator The failed GEN is replaced automatically by the APU GEN if available, otherwise by the other engine GEN The bus tie contactors make the transfer Part of the galley load and the DC BUS Ent are shed With automatic galley shedding: all the galley load is shed Panel: GEN FAULT ; ELEC page: GEN OFF , GALLEY SHED AC 1 AC 2 G1 APU G2 GEN 1 lost, APU on one BTC closed APU available: it replaces GEN 1 No APU: GEN 2 feeds both buses Part of the galley load and the DC BUS Ent are shed
Chapter 12 · Electrical Distribution, Emergency Configuration and ELEC Panel
12
e-books by eatpl.in · © 2026 · Do not copy or distribute
Let us lose one engine generator in flight. Watch the aircraft: generator one fails and its supply line goes grey, while generator two keeps feeding its own side. The system replaces the failed generator automatically. If the APU generator is available, the APU replaces generator one through a bus tie contactor. If it is not, generator two takes over both AC buses. Either way, the crew sees the generator FAULT light on the panel, and on the ELEC page that generator shows OFF. With only one generator left in flight, part of the galley load is shed and GALLEY SHED appears, and the entertainment DC bus is shed too. On aircraft with automatic galley load shedding, all the galley load goes. Every essential system keeps its power.
Failures
GEN 1 lost, no APU: what you see DC BUS 1 DC BUS 2 AC BUS 1 AC BUS 2 AC ESS BUS COMMERCIAL OFF BAT 1 28.1 V 1 BAT 2 FAULT OFF FAULT OFF BAT 2 28.2 V AC ESS FEED FAULT ALTN GALLEY FAULT OFF A U T O IDG 1 FAULT IDG 2 FAULT GEN 1 FAULT OFF APU GEN FAULT OFF GEN 2 FAULT OFF EXT PWR AVAIL ON BUS TIE OFF A U T O E L E C E L E C ELEC DC BAT DC 1 DC 2 DC ESS AC 1 AC 2 AC ESS BAT 1 28 V 0 A BAT 2 28 V 0 A TR 1 28 V 150 A TR 2 28 V 150 A ESS TR EMER GEN GEN 1 OFF GEN 2 52 % 116 V 400 HZ APU GEN IDG 1 110 °C 115 °C IDG 2 GALLEY SHED TAT -21 °C SAT -42 °C 14 H 05 GW 64200 KG 1 GEN 1 pb: amber FAULT (GCU trip) 2 BTCs close: GEN 2 feeds AC BUS 1 as well 3 GEN 2 load rises (here 52 %) 4 GALLEY SHED: main galley, in-seat power, IFE shed 5 DC BUS Ent shed (some aircraft)
Chapter 12 · Electrical Distribution, Emergency Configuration and ELEC Panel
13
e-books by eatpl.in · © 2026 · Do not copy or distribute
Here is the cockpit picture when generator one fails and the APU is not running. On the panel, the amber FAULT light is on in the GEN one button: its generator control unit has tripped it. The procedure will ask you to try a reset, off then on, but remember that after a differential fault it will not work after two attempts. On the ELEC page, the generator one box reads GEN OFF, and the green line now runs from generator two, along the bus tie line, up into AC bus one: both bus tie contactors are closed. Generator two carries the whole network, so its load figure rises, here to fifty two per cent. And at the bottom, GALLEY SHED tells you the main galley, in-seat power and entertainment have been shed. Everything else is still green.
Failures
Failure of AC BUS 1 DC BAT BUS HOT BUS 1 HOT BUS 2 DC BUS 1 DC ESS BUS DC ESS SHED DC BUS 2 AC STAT INV AC ESS SHED AC ESS BUS AC BUS 1 AC BUS 2 GEN 1 APU GEN GEN 2 EXT PWR EMER GEN TR 1 TR 2 ESS TR STAT INV BAT 1 BAT 2 AC powered DC powered not powered open contactor AC BUS 2 takes over the AC ESS (automatically with auto switching, otherwise AC ESS FEED to ALTN); the ESS TR feeds the DC ESS; after 5 s DC BUS 2 feeds DC BUS 1 and the DC BAT BUS.
Chapter 12 · Electrical Distribution, Emergency Configuration and ELEC Panel
14
e-books by eatpl.in · © 2026 · Do not copy or distribute
Now a bus fault rather than a generator fault: AC bus one itself is lost. Generator two cannot simply take over through the bus ties, because the fault is on the bus. Look at what happens instead. On the AC side, AC bus two takes over the AC essential bus through the AC ESS FEED contactors. That is automatic on aircraft with auto switching; on the others the crew selects AC ESS FEED to ALTN. T R one has lost its input, so the essential T R starts working, taking AC from the essential side and feeding the DC essential bus. On the DC side, after five seconds, DC bus two automatically supplies the DC battery bus and DC bus one through the DC tie contactors. The result: everything except AC bus one and its direct users is powered again.
Failures
Losing one TR, or both A TR opens its own contactor on overheat or minimum current One TR lost: the other TR takes over its DC bus; the ESS TR feeds the DC ESS BUS TR 1 lost: DC 1 and DC BAT fed from DC 2 ; ESS TR from the AC ESS side TR 1 and TR 2 lost: DC BUS 1, DC BUS 2 and DC BAT BUS lost ; DC ESS on the ESS TRELEC page: failed TR amber, ESS TR box appears ELEC DC BAT DC 1 DC 2 DC ESS AC 1 AC 2 AC ESS BAT 1 28 V 0 A BAT 2 28 V 0 A TR 1 0 V 0 A TR 2 28 V 190 A ESS TR 28 V 60 A EMER GEN GEN 1 26 % 116 V 400 HZ GEN 2 26 % 116 V 400 HZ APU GEN IDG 1 110 °C 115 °C IDG 2 TAT -21 °C SAT -42 °C 14 H 05 GW 64200 KG
Chapter 12 · Electrical Distribution, Emergency Configuration and ELEC Panel
15
e-books by eatpl.in · © 2026 · Do not copy or distribute
Each transformer rectifier watches itself and opens its own contactor if it overheats, or if its current falls to a minimum, which suggests it is no longer delivering. When one T R is lost, the other T R takes over its DC bus, and the essential T R takes over the DC essential bus. On this ELEC page, T R one has failed: its box is amber at zero volts and zero amps. DC one and the DC battery bar are still green, because DC two now feeds them through the tie contactors, and T R two has picked up the extra load, here one hundred and ninety amps. The essential T R box has appeared and feeds DC essential. If both T R one and T R two fail, DC bus one, DC bus two and the DC battery bus are lost, and only the essential T R keeps DC essential alive.
Distribution table
Who feeds what: normal and DC failures Bus Normal One GEN inop. TR 1 fault TR 2 fault TR 1 + 2 fault AC BUS 1 / AC BUS 2 GEN 1 / GEN 2 remaining GEN or APU GEN 1 / GEN 2 GEN 1 / GEN 2 GEN 1 / GEN 2 AC ESS, AC SHED ESS GEN 1 (via AC 1) available GEN GEN 1 GEN 1 GEN 1 DC BUS 1 TR 1 TR 1 TR 2 TR 1 lost DC BUS 2 TR 2 TR 2 TR 2 TR 1 lost DC BAT BUS TR 1 TR 1 TR 2 TR 1 lost DC ESS, DC SHED ESS TR 1 TR 1 ESS TR ESS TR ESS TR ESS TR idle idle GEN 1 (AC ESS side) GEN 1 (AC ESS side) GEN 1 (AC ESS side) HOT BUS 1 / 2 BAT 1 / BAT 2 BAT 1 / BAT 2 BAT 1 / BAT 2 BAT 1 / BAT 2 BAT 1 / BAT 2
DC BUS Ent: TR Ent on GEN 2 in normal flight; shed with one generator in flight (needs two generators), lost with a TR fault.
Chapter 12 · Electrical Distribution, Emergency Configuration and ELEC Panel
16
e-books by eatpl.in · © 2026 · Do not copy or distribute
This table is the compact way to revise distribution, and it is worth learning. In normal flight generator one feeds AC bus one, the essential AC buses, and through T R one, DC bus one, the DC battery bus and the essential DC buses; generator two and T R two look after the other side. With one generator inoperative, the remaining generator or the APU takes its place and nothing else changes. With T R one at fault, T R two carries DC one, DC two and the DC battery bus, and the essential T R takes the essential DC buses. With T R two at fault it is the mirror image, T R one carrying all three. With both T Rs gone, the three main DC buses are lost and only the essential T R remains. The hot buses, of course, always stay on the batteries.
Emergency configuration
Loss of all main generators DC BAT BUS HOT BUS 1 HOT BUS 2 DC BUS 1 DC ESS BUS DC ESS SHED DC BUS 2 AC STAT INV AC ESS SHED AC ESS BUS AC BUS 1 AC BUS 2 GEN 1 APU GEN GEN 2 EXT PWR EMER GEN TR 1 TR 2 ESS TR STAT INV BAT 1 BAT 2 AC powered DC powered not powered open contactor AC BUS 1 and 2 lost above 100 kt: the RAT extends, blue drives the EMER GEN, and only the essential buses stay powered.
Chapter 12 · Electrical Distribution, Emergency Configuration and ELEC Panel
17
e-books by eatpl.in · © 2026 · Do not copy or distribute
Now the big one: both engine generators are lost and no APU generator is available, so AC bus one and AC bus two are both dead. Watch the aircraft. The supply lines from both engines go grey. Because the speed is above one hundred knots, the ram air turbine extends automatically, the blue system is pressurised, and blue hydraulic power drives the emergency generator. The emergency generator then supplies the AC essential bus, and the DC essential bus through the essential T R. So the aircraft is left with its essential buses only, and the shed parts of them, enough to fly, navigate, communicate and land, but nothing more. This is the emergency electrical configuration, and the next slides take it step by step.
Emergency configuration
The emergency configuration, step by step t = 0 AC BUS 1 and 2 lost above 100 kt about 8 s EMER GEN coupled memo EMER GEN approach EMER GEN still on landing roll below 100 kt, then 50 kt Batteries bridge the gap BAT 1 via STAT INV: AC ESS BAT 2: DC ESS · shed buses off Emergency generator running (RAT and blue) AC ESS + AC SHED ESS · ESS TR: DC ESS + DC SHED ESS batteries off line (hot buses only) batteries again next slides RAT extends, blue pressure, EMER GEN spins up Lost throughout: AC BUS 1 and 2, DC BUS 1 and 2, DC BAT BUS (in flight), galleys and every non-essential user Kept: the essential buses, so the aircraft can be flown, navigated and landed from the left seat instruments
Chapter 12 · Electrical Distribution, Emergency Configuration and ELEC Panel
18
e-books by eatpl.in · © 2026 · Do not copy or distribute
Here is the emergency configuration as a timeline. At time zero AC bus one and two are lost above one hundred knots. For the first eight seconds or so, while the RAT extends and the emergency generator spins up and couples, the batteries carry the essential network: battery one through the static inverter supplies the AC essential bus, and battery two supplies the DC essential bus, with both shed buses switched off. Then the emergency generator comes on line and the green EMER GEN memo appears. Now the emergency generator supplies the AC essential bus and the AC shed essential bus, and through the essential T R the DC essential and DC shed essential buses, while the batteries go back to looking after the hot buses. That lasts all the way to the landing roll, which we look at shortly.
Emergency configuration
The ELEC page with the EMER GEN running ELEC DC BAT DC 1 DC 2 DC ESS AC 1 AC 2 AC ESS BAT 1 28 V 0 A BAT 2 28 V 0 A TR 1 28 V 150 A TR 2 28 V 150 A ESS TR EMER GEN GEN 1 26 % 116 V 400 HZ GEN 2 26 % 116 V 400 HZ APU GEN IDG 1 110 °C 115 °C IDG 2 TAT -21 °C SAT -42 °C 14 H 05 GW 64200 KG ELEC DC BAT DC 1 DC 2 DC ESS AC 1 AC 2 AC ESS BAT 1 28 V 0 A BAT 2 28 V 0 A TR 1 0 V 0 A TR 2 0 V 0 A ESS TR 28 V 130 A EMER GEN 116 V 400 HZ GEN 1 OFF GEN 2 OFF APU GEN IDG 1 40 °C 43 °C IDG 2 TAT -21 °C SAT -42 °C 14 H 05 GW 64200 KG Normal flight EMER GEN running Amber: AC 1, AC 2, DC 1, DC 2, DC BAT EMER GEN box: V, Hz ESS TR box feeds DC ESS GEN 1 + 2 OFF TR 1 + 2 amber at 0
Chapter 12 · Electrical Distribution, Emergency Configuration and ELEC Panel
19
e-books by eatpl.in · © 2026 · Do not copy or distribute
Compare the two ELEC pages. On the left, normal flight, everything green. On the right, the emergency generator is running. Almost every bar has turned amber: AC one, AC two, DC one, DC two and DC battery. Both generators show GEN OFF, and both T Rs are amber at zero volts and zero amps. In the middle you see what keeps the aircraft going: the emergency generator box with one hundred and sixteen volts and four hundred hertz, feeding down into the green AC essential bar and sideways into the essential T R, whose box shows twenty eight volts and one hundred and thirty amps feeding up into the green DC essential bar. The batteries show zero amps, with their contactors open. Learn this picture: it is a favourite in type-rating exams.
Emergency configuration
What starts the emergency generator? Automatic : speed above 100 kt (ADIRS 1) and AC BUS 1 and AC BUS 2 unpoweredOr MAN ON on the EMER ELEC PWR panel Either one extends the RAT and starts the GCU , which couples the EMER GEN RAT MAN ON on the HYD panel: extends the RAT for blue only EMER GEN TEST also starts the GCU (blue electric pump drives it)ADIRS 1: speed > 100 kt AC BUS 1 not powered AC BUS 2 not powered & RAT MAN ON (HYD panel) OR RAT solenoid 1 MAN ON (EMER ELEC PWR) OR RAT solenoid 2 EMER GEN TEST OR GCU EMER GEN on line AC ESS + ESS TR RAT MAN ON on the HYD panel extends the RAT for blue only: it does not start the emergency generator logic.
Chapter 12 · Electrical Distribution, Emergency Configuration and ELEC Panel
20
e-books by eatpl.in · © 2026 · Do not copy or distribute
It is worth knowing exactly what starts the emergency generator. The automatic path is an AND gate: speed above one hundred knots from air data reference one, AC bus one unpowered and AC bus two unpowered. That condition, or a press on MAN ON on the EMER ELEC PWR panel, extends the RAT and starts the emergency generator control unit, which couples the generator. Now the trap. There is a second RAT button, RAT MAN ON on the HYD panel. It also extends the RAT, but it only gives you blue hydraulic pressure; it does not start the emergency generator logic. So if you need electrical power from the RAT, use the button on the EMER ELEC PWR panel. Finally, the EMER GEN TEST button also starts the control unit, with the blue electric pump providing the drive.
Emergency configuration
Flight on batteries only DC BAT BUS HOT BUS 1 HOT BUS 2 DC BUS 1 DC ESS BUS DC ESS SHED DC BUS 2 AC STAT INV AC ESS SHED AC ESS BUS AC BUS 1 AC BUS 2 GEN 1 APU GEN GEN 2 EXT PWR EMER GEN TR 1 TR 2 ESS TR STAT INV BAT 1 BAT 2 AC powered DC powered not powered open contactor RAT stalled (or not yet coupled): BAT 1 to STAT INV to AC ESS and AC STAT INV; BAT 2 to DC ESS. AC ESS SHED and DC ESS SHED are shed.
Chapter 12 · Electrical Distribution, Emergency Configuration and ELEC Panel
21
e-books by eatpl.in · © 2026 · Do not copy or distribute
What if the emergency generator has nothing to drive it, because the RAT has stalled, or the aircraft is already below one hundred knots on the ground? Then the essential network transfers automatically to the batteries and the static inverter, and both shed buses are switched off. Follow the diagram. Battery one feeds the static inverter, which supplies the AC static inverter bus and the AC essential bus. Battery two feeds the DC essential bus directly. Everything else is dark, including the DC battery bus in flight. The ELEC page shows the shed state with amber SHED legends. Remember the sizes: a twenty three ampere hour battery and a one kilovolt ampere inverter. This configuration is meant to last only for the time it takes to get the aircraft on the ground.
Emergency configuration
The landing roll: 100 kt and 50 kt On the ground below 100 kt : the EMER GEN drops out; the DC BAT BUS is connected to the batteries Static inverter keeps the AC ESS; shed buses off Below 50 kt : the AC ESS BUS is shed : all display units are lost On batteries only, APU start is available only below 100 kt Worked example: 140 kt, 2.5 kt per second: 100 kt after 16 s , 50 kt after 36 s 0 50 100 150 0 10 20 30 40 50 60 time after touchdown (s) ground speed (kt) 16 s 36 s EMER GEN batteries AC ESS on AC ESS shed displays lost Touchdown at 140 kt, braking at 2.5 kt per second
Chapter 12 · Electrical Distribution, Emergency Configuration and ELEC Panel
22
e-books by eatpl.in · © 2026 · Do not copy or distribute
The emergency configuration ends on the landing roll, and two speeds matter. Below one hundred knots on the ground, the emergency generator is no longer used: the essential network goes back to the batteries and the static inverter, and the DC battery bus is connected to the batteries. Below fifty knots, the AC essential bus is shed as well, and with it all the display units go dark. Let us put numbers on it. Touch down at one hundred and forty knots and decelerate steadily at two and a half knots per second. You reach one hundred knots after forty divided by two point five, which is sixteen seconds, and fifty knots after ninety divided by two point five, thirty six seconds. So expect the screens to go out about twenty seconds after the batteries take over. And remember: on batteries, the APU can only be started below one hundred knots.
Distribution table
Emergency and battery configurations Configuration AC ESS AC SHED ESS AC STAT INV DC BAT BUS DC ESS DC SHED ESS Before EMER GEN (about 8 s) STAT INV shed STAT INV not powered BAT 2 shed EMER GEN running EMER GEN EMER GEN not powered not powered ESS TR ESS TR Batteries only: RAT stall, or ground 50 to 100 kt STAT INV shed STAT INV BAT 1 + 2 (ground) BAT 2 shed Ground, 50 kt or less shed shed STAT INV BAT 1 + 2 BAT 2 shed
The static inverter runs on BAT 1. Hot buses: always on the batteries. AC BUS 1 and 2, DC BUS 1 and 2 and the TRs: not powered in all four rows. Above 100 kt on the ground: as EMER GEN running.
Chapter 12 · Electrical Distribution, Emergency Configuration and ELEC Panel
23
e-books by eatpl.in · © 2026 · Do not copy or distribute
Here is the emergency part of the distribution table. In the eight seconds or so before the emergency generator is available, the static inverter, from battery one, feeds the AC essential bus and its own static inverter bus, battery two feeds the DC essential bus, and both shed buses are off. With the emergency generator running, it feeds both AC essential buses, and the essential T R feeds both DC essential buses. On batteries only, after a RAT stall in flight or between fifty and one hundred knots on the ground, we are back to the static inverter and battery two, and on the ground the DC battery bus is on both batteries. At fifty knots or less, even the AC essential bus is shed, and only the static inverter bus, the DC battery bus and the DC essential bus remain.
Smoke configuration
GEN 1 LINE and the smoke configuration GEN 1 LINE OFF: GEN 1 line contactor opens; the AC BUS 1 channel is fed by GEN 2 through the bus ties (smoke drill)The SMOKE light belongs to the avionics smoke detection (fire protection lesson) Smoke configuration: the main bus bars are shed ; distribution as in the emergency configuration Difference: the fuel pumps stay fed from upstream of the GEN 1 line contactor About 75 % of the equipment is shed; what remains is on overhead panel C/Bs (or hot buses) EMER ELEC PWR EMER GEN TEST GEN 1 LINE SMOKE OFF RAT & EMER GEN FAULT MAN ON A U T O GEN 1 LINE OFF: GEN 1 line contactor opens; the AC BUS 1 channel is fed by GEN 2 through the bus ties (smoke drill) Smoke configuration: main bus bars shed, as in the emergency configuration, but the fuel pumps stay fed upstream of the GEN 1 line contactor About 75 % of the equipment is shed
Chapter 12 · Electrical Distribution, Emergency Configuration and ELEC Panel
24
e-books by eatpl.in · © 2026 · Do not copy or distribute
The GEN 1 LINE button on the EMER ELEC PWR panel is used for smoke. Selecting it OFF opens the generator one line contactor, so generator one stops feeding the network, and the AC bus one channel is supplied from generator two through the bus ties. Its amber SMOKE light belongs to the avionics smoke detection, which we cover in the fire protection lesson. The smoke procedure goes further and puts the aircraft in the smoke configuration. The main bus bars are shed and the distribution is the same as in the emergency electrical configuration, with one important difference: the fuel pumps stay connected upstream of the generator one line contactor, so generator one keeps them running. About seventy five per cent of the electrical equipment is shed, and what remains is protected by circuit breakers on the overhead panel, apart from hot bus equipment. The ELEC page looks just like the EMER GEN running page.
Ground servicing
The MAINT BUS switch In the forward entrance area : powers servicing loads without the whole aircraft Latches magnetically only if external power is connected and normal (AVAIL on) Powers the AC and DC GND/FLT buses : cabin lights, service outlets, yellow hydraulic pump, refuelling, nav lights, PA, interphone Trips when the external source is removedNormally the GND/FLT buses are fed from AC BUS 2 and DC BUS 2 MAINT BUS ON OFF forward entrance area Latches magnetically only with EXT PWR connected and normal (AVAIL light on); trips when the external source is removed AC GND/FLT DC GND/FLT normally fed from AC BUS 2 and DC BUS 2 Typical loads it powers without the rest of the aircraft: cabin, galley, entrance, lavatory lights vacuum cleaner and service outlets yellow hydraulic pump flight deck flood lights fuel quantity indication and refuelling cargo, wheel well, equipment bay lights navigation lights ground call, passenger address, interphone
Chapter 12 · Electrical Distribution, Emergency Configuration and ELEC Panel
25
e-books by eatpl.in · © 2026 · Do not copy or distribute
On the ground, the cleaners, the caterers and the refuellers need power, but there is no reason to power the whole aircraft for them. That is what the MAINT BUS switch is for. It sits in the forward entrance area, and it latches magnetically only if external power is connected and normal, with its AVAIL light on. It then powers the AC and DC ground and flight buses directly from external power, and with them a list of servicing loads: cabin, galley and lavatory lighting, vacuum cleaner and service outlets, the yellow hydraulic pump, flood lights, fuel quantity indication and refuelling, cargo and wheel well lights, navigation lights, ground call, passenger address and interphone. If the external power is removed, the switch trips. In normal operation the ground and flight buses are supplied from AC bus two and DC bus two.
Protection
Circuit breakers and C/B TRIPPED Monitored C/Bs (green): out for more than 1 min gives C/B TRIPPED on the ECAMNon-monitored C/Bs are black; wing tip brake C/Bs have red caps : do not resetThe caution shows the panel : OVHD PNL, L (R) ELEC BAY, REAR PNL J-M, N-R, S-V, W-Z EMER CANC : clears and inhibits it for the rest of the flightCLR : clears only; if the C/B stays out, new trips on that panel are not detected Monitored green collar Not monitored black WTB C/B red cap: never reset C/B TRIPPED monitored C/B out for more than 1 min ECAM shows where: OVHD PNL, L (R) ELEC BAY, REAR PNL J-M, N-R, S-V or W-Z Clear it with EMER CANC or CLR (see right) EMER CANC clears the caution and inhibits it for the rest of the flight CLR clears it only. C/B still out: a new trip on the same panel is NOT detected. C/B pushed back in: new trips are detected again
Chapter 12 · Electrical Distribution, Emergency Configuration and ELEC Panel
26
e-books by eatpl.in · © 2026 · Do not copy or distribute
Circuit breakers protect each circuit, and the A320 has two kinds. Monitored circuit breakers have a green collar: if one stays out for more than one minute, the ECAM shows a C/B TRIPPED caution with the location, such as the overhead panel, the left or right electrical bay, or one of the rear panels. Non-monitored ones are black. The wing tip brake circuit breakers have red caps, which tell you never to reset them. Now the subtle part, about clearing the caution. EMER CANC clears it and inhibits it for the rest of the flight. CLR only clears it: if the breaker stays pulled, any further breaker tripping on the same panel will not be detected; if the breaker is pushed back in, new trips will be detected and the caution will come back.
Summary
Electrical distribution in one page Normal GEN 1: AC 1 and AC ESS; GEN 2: AC 2. TR 1: DC 1, DC BAT, DC ESS; TR 2: DC 2. BTCs open.
Bus ties and feed One BTC closed with APU/EXT on one side, both with one source. AC ESS FEED ALTN: AC 2.
Single failures GEN: APU or other GEN replaces it, galley shed. AC BUS 1: AC 2 to AC ESS, DC 2 to DC 1 after 5 s. TR: ESS TR to DC ESS.
Emergency AC 1 + 2 lost above 100 kt: RAT, EMER GEN on the essential buses; about 8 s on batteries first.
Batteries only BAT 1 via STAT INV: AC ESS; BAT 2: DC ESS; sheds off. Ground: 100 kt DC BAT on batteries, 50 kt AC ESS shed.
Also Smoke config: 75 % shed, fuel pumps upstream of GEN 1 LINE. MAINT BUS on EXT PWR. C/B TRIPPED after 1 min.
Chapter 12 · Electrical Distribution, Emergency Configuration and ELEC Panel
27
e-books by eatpl.in · © 2026 · Do not copy or distribute
To close the electrical chapter: in normal flight each generator feeds its own side, AC bus one feeds the essential AC, and T R one feeds DC one, the DC battery bus and the DC essential bus. The bus ties close one at a time when the APU or ground power shares the load, and both when one source carries everything. A failed generator is replaced by the APU or the other generator, with galley shedding. If AC bus one is lost, AC bus two takes the essential bus and DC two feeds DC one after five seconds. A failed T R hands its work to the other and to the essential T R. With both AC buses lost above one hundred knots, the RAT drives the emergency generator for the essential buses. On batteries, battery one feeds AC essential through the inverter and battery two feeds DC essential, until fifty knots on the landing roll.