A320 Aircraft Systems · Chapter 11
Electrical Generation Where the A320 gets its electricity: two engine generators, the APU generator, external power, the emergency generator, two batteries, the TRs and the static inverter.
DC BUS 1 DC BUS 2 AC BUS 1 AC BUS 2 AC ESS BUS COMMERCIAL OFF BAT 1 28.1 V 1 BAT 2 FAULT OFF FAULT OFF BAT 2 28.2 V AC ESS FEED FAULT ALTN GALLEY FAULT OFF A U T O IDG 1 FAULT IDG 2 FAULT GEN 1 FAULT OFF APU GEN FAULT OFF GEN 2 FAULT OFF EXT PWR AVAIL ON BUS TIE OFF A U T O E L E C E L E C ELEC DC BAT DC 1 DC 2 DC ESS AC 1 AC 2 AC ESS BAT 1 28 V 0 A BAT 2 28 V 0 A TR 1 28 V 150 A TR 2 28 V 150 A ESS TR EMER GEN GEN 1 26 % 116 V 400 HZ GEN 2 26 % 116 V 400 HZ APU GEN IDG 1 110 °C 115 °C IDG 2 TAT -21 °C SAT -42 °C 14 H 05 GW 64200 KG © 2026 eatpl.in. For the personal study of eatpl.in students only. Do not copy or distribute.
e-books by eatpl.in · © 2026 · Do not copy or distribute
Welcome to electrical generation on the A320. Almost everything on this aircraft, from the flight control computers to the coffee maker, runs on electricity, so the system is built with layers of back-up. In this lesson we meet every source: the two engine generators with their integrated drives, the APU generator, ground power, the emergency generator driven by the blue hydraulic system, the static inverter and the two batteries, and the transformer rectifiers that make DC. For each one you will learn what it produces, who controls it, which pushbutton and lights belong to it and how it looks on the ECAM ELEC page. The next lesson then shows how all this power is distributed, and what happens when sources fail.
Electrical generation
Our route through ATA 24 generation DC BUS 1 DC BUS 2 AC BUS 1 AC BUS 2 AC ESS BUS COMMERCIAL OFF BAT 1 28.1 V 1 BAT 2 FAULT OFF FAULT OFF BAT 2 28.2 V AC ESS FEED FAULT ALTN GALLEY FAULT OFF A U T O IDG 1 FAULT IDG 2 FAULT GEN 1 FAULT OFF APU GEN FAULT OFF GEN 2 FAULT OFF EXT PWR AVAIL ON BUS TIE OFF A U T O E L E C E L E C The system AC 115/200 V 400 Hz and DC 28 V; priorities and rules.
Main AC sources IDGs and GEN 1 and 2, APU GEN, external power.
Back-up sources The emergency generator, the static inverter, EMER ELEC PWR panel.
DC sources TR 1, TR 2, ESS TR, the batteries and their charge limiters.
Chapter 11 · Electrical Generation
2
e-books by eatpl.in · © 2026 · Do not copy or distribute
Here is our route through the generation half of chapter twenty four. First the big picture: what kind of electricity the A320 uses, and the simple rules that decide which source feeds the network. Then the main AC sources: the two engine generators with their integrated drives, the APU generator and external power, each with its pushbutton on the ELEC panel, shown here, and its box on the ECAM ELEC page. Third, the back-up sources: the emergency generator that the blue hydraulic system drives, and the static inverter that makes AC from a battery. And last the DC side: the three transformer rectifiers and the two batteries with their charge limiters. Distribution and failures follow in the next lesson.
The system
AC first, DC from AC Main system: three-phase 115/200 V, 400 Hz , constant frequency AC Secondary system: 28 V DC , made from AC by transformer rectifiers Normal sources: GEN 1 , GEN 2 and the APU GEN ; each can feed every bus bar No normal AC: the emergency generator supplies AC No AC at all: the static inverter makes AC from battery DC Normal sources GEN 1 90 kVA APU GEN same output EXT PWR ground GEN 2 90 kVA AC network three-phase 115/200 V, 400 Hz TR 1 ESS TR TR 2 DC network 28 V Back-up sources EMER GEN blue hydraulic, 5 kVA BATTERIES 2 x 23 Ah STATIC INVERTER BAT 1 to 1 kVA AC all main AC lost hot buses, DC back-up all AC lost TRs turn AC into DC; the static inverter turns battery DC into AC
Chapter 11 · Electrical Generation
3
e-books by eatpl.in · © 2026 · Do not copy or distribute
The A320 is an AC aeroplane first. Its main system is three-phase alternating current at one hundred and fifteen over two hundred volts and a constant four hundred hertz. A part of that AC is converted into twenty eight volts DC by transformer rectifiers, T Rs for short, for the equipment that needs direct current. Normally the power comes from three generators: one on each engine and one on the APU, and any one of them is able to feed every bus bar. External power does the same job on the ground. If normal AC is lost, an emergency generator, driven by the blue hydraulic system, takes over the essential equipment. And if even that is not available, the static inverter turns battery DC back into AC. Notice the layers: main, emergency, battery.
Where the sources are
The AC sources on the aircraft G IDG + GEN 1 (and 2) driven by each engine, 90 kVA APU GEN driven directly by the APU EXT PWR connector near the nose wheel EMER GEN driven by the blue hydraulic system Sources of AC power on the A320 (schematic, not to scale) Engine generators, APU generator and ground power feed the main network; the blue hydraulic system drives the emergency generator.
Chapter 11 · Electrical Generation
4
e-books by eatpl.in · © 2026 · Do not copy or distribute
Let us place the sources on the aeroplane. Each engine drives its own integrated drive generator, so the first two sources sit in the engine nacelles, one on each side, rated at ninety kilovolt amperes each. Back in the tail, the APU drives the third generator directly, with the same output as an engine generator. Up front, near the nose wheel, is the ground power connector, where a ground power unit plugs in at the gate. And running down the middle of the aircraft is the blue hydraulic system, which is the energy source for the emergency generator: if all the main generators fail in flight, the ram air turbine pressurises blue, and blue spins the emergency generator. Keep this picture in mind for the rest of the lesson.
The system
Priorities: who feeds the buses? GEN 1 and GEN 2 , when running, have priority over the APU GEN and external powerExternal power has priority over the APU GEN when the EXT PWR pb is ON The APU GEN or external power alone can supply the entire network One engine generator can supply the entire network except the DC BUS Ent Generators are never connected in parallel Who supplies the AC buses? 1 GEN 1 / GEN 2 engine generators, when running 2 EXT PWR when its pb is ON (blue light) 3 APU GEN when nothing above is available Never in parallel: one source per AC bus APU GEN or EXT PWR alone: the whole network One engine GEN alone: everything except the DC BUS Ent (IFE, some aircraft)
Chapter 11 · Electrical Generation
5
e-books by eatpl.in · © 2026 · Do not copy or distribute
Now the rules that decide who supplies the AC buses. First, the engine generators win: when they are running and selected on, they have priority over both the APU generator and external power. Second, between the two ground sources, external power has priority over the APU generator, provided the crew has pressed the EXT PWR button so that it shows ON. Third, any single source is big enough. The APU generator alone, or external power alone, can supply the entire network, and a single engine generator can supply everything except the entertainment DC bus fitted on some aircraft, which needs two generators in flight. And remember the golden rule: the A320 never connects two generators in parallel. Each AC bus is fed by exactly one source at a time.
Main AC sources
The integrated drive generator Each engine drives GEN 1 or GEN 2 through an integrated drive Up to 90 kVA , three-phase 115/200 V, 400 Hz Constant frequency, whatever the engine speed A GCU (generator control unit) per generator: controls voltage and frequency The GCU protects the network by controlling the generator line contactor (GLC) Engine gearbox (N2) IDG Drive constant speed GEN 90 kVA GLC AC BUS GCU generator control unit GCU: regulates voltage and frequency and opens the line contactor (GLC) to protect the network N2 varies 400 Hz constant
Chapter 11 · Electrical Generation
6
e-books by eatpl.in · © 2026 · Do not copy or distribute
Each engine drives its generator through the accessory gearbox, whose speed follows N two. If the generator were driven directly, its frequency would wander as the thrust changed. So the generator is combined with an integrated drive in one unit, the I D G. Watch the scene: as the engine speed climbs, the input shaft speeds up, but the integrated drive keeps turning the generator at a constant speed, so the output frequency stays at four hundred hertz. The generator itself is rated at ninety kilovolt amperes. Each generator has its own generator control unit, the G C U, which controls the voltage and frequency of the output and protects the network by controlling the generator line contactor, the switch between the generator and its AC bus.
Main AC sources
The IDG pushbutton Guarded, spring-loaded out; pressing it disconnects the IDG from its drive shaft Reconnection: only by maintenance , on the ground Amber FAULT : IDG oil outlet above 180 °C , or oil pressure low (inhibited below 14 % N2 ); out once disconnected Automatic thermal disconnection at 200 °C Hold no more than 3 s ; disconnect only with the engine running or windmilling IDG 1 (2) pb, guarded FAULT Normal guard closed, lights out FAULT FAULT oil hot or oil pressure low FAULT Pressed IDG disconnected: light out FAULT: oil outlet above 180 °C, or oil pressure low (low pressure inhibited below 14 % N2) Auto thermal disconnect at 200 °C Hold no longer than 3 s; only with the engine running or windmilling; reconnection on the ground by maintenance only
Chapter 11 · Electrical Generation
7
e-books by eatpl.in · © 2026 · Do not copy or distribute
The I D G button sits under a red guard, because pressing it is irreversible in flight. It disconnects the drive from the engine, and only maintenance can reconnect it, on the ground. Its amber FAULT light comes on when the I D G oil at the outlet is hotter than one hundred and eighty degrees, or when the oil pressure is low. The low pressure part is inhibited at low engine speed, below fourteen per cent N two, so it does not light during every engine start. Once the I D G is disconnected, the light goes out. If the temperature reaches two hundred degrees, the I D G disconnects itself. Two cautions: do not hold the button for more than three seconds, or you may damage the mechanism, and only disconnect with the engine running or windmilling.
Main AC sources
The GEN 1 (2) pushbutton ON (lights out): field energised; the GLC closes if parameters are normalOFF : field de-energised, GLC opens, fault circuit reset Amber FAULT : the GCU has tripped the generator, or the GLC opened (not when selected OFF) After a differential fault , a reset has no effect after two attempts IDG pb disconnects the drive; GEN pb switches the electrical output GEN 1 (2) pb FAULT OFF ON lights out FAULT OFF OFF field off, GLC open FAULT OFF FAULT GCU trip or GLC open ON: field energised, GLC closes if parameters normal OFF: field de-energised, GLC opens, fault circuit reset FAULT: the GCU has tripped the generator, or the line contactor opened (not when selected OFF) Differential fault: reset ineffective after 2 attempts
Chapter 11 · Electrical Generation
8
e-books by eatpl.in · © 2026 · Do not copy or distribute
Do not confuse the GEN button with the I D G button. The I D G button deals with the mechanical drive; the GEN button deals with the electrical output. With GEN on, all lights out, the generator field is energised and the line contactor closes, as long as the voltage and frequency are normal. Selecting OFF de-energises the field, opens the line contactor and resets the fault circuit, which is why the checklists often ask for OFF and then ON as a reset. The amber FAULT light means the generator control unit has tripped the generator, or the line contactor has opened when the crew did not select OFF. One trap for the exam: if the trip was caused by a differential fault, the reset will not work after two attempts.
Main AC sources
GEN and IDG on the ELEC page GEN box: load % , voltage , frequency ; legend amber if any value is amber Amber: load above 100 % , voltage outside 110 to 120 V , frequency outside 390 to 410 Hz pb OFF: GEN OFF ; the number is amber when that engine is not running IDG temperature green; pulses from 147 to 180 °C; amber above 180 °C LO PR (engine running) and DISC appear in amberGEN 1 (2) on the ELEC page GEN 1 26 % 116 V 400 HZ normal GEN 1 104 % 116 V 400 HZ load above 100 % GEN 1 OFF pb OFF; amber 1: engine not running Amber limits: voltage below 110 or above 120 V; frequency below 390 or above 410 Hz. IDG line under the GEN box IDG 1 110 °C normal (pulses 147 to 180 °C) IDG 1 185 °C overheat above 180 °C IDG 1 LO PR low oil pressure, engine running IDG 1 DISC IDG disconnected Some aircraft also show an IDG temperature RISE value.
Chapter 11 · Electrical Generation
9
e-books by eatpl.in · © 2026 · Do not copy or distribute
On the ECAM ELEC page each engine generator has a box with three values: load in per cent, voltage and frequency, normally green with cyan units. A value turns amber if the load goes above one hundred per cent, the voltage leaves the band from one hundred and ten to one hundred and twenty volts, or the frequency leaves the band from three hundred and ninety to four hundred and ten hertz, and then the GEN legend turns amber too. With the button off, the box simply reads GEN OFF, and the generator number is amber if its engine is not running. Below the box is the I D G line. The oil temperature is green, pulses as an advisory from one hundred and forty seven to one hundred and eighty degrees, and turns amber above that. LO PR and DISC appear in amber.
Main AC sources
The APU generator Driven directly by the APU ; same output as an engine generator Can replace either or both engine generators at any time pb ON: GLC closes if parameters normal and the EXT PWR contactor is open ; the bus tie closes if GEN 1 (2) is not operating FAULT as for GEN 1 or 2, with ELEC APU GEN FAULT FAULT inhibited: APU speed too low , or GLC opened because EXT PWR or an engine GEN took over APU GEN pb FAULT OFF ON: lights out FAULT OFF OFF FAULT OFF FAULT APU GEN box on the ELEC page APU GEN MASTER SW OFF APU GEN OFF MASTER SW ON, APU GEN pb OFF APU GEN 38 % 115 V 400 HZ both ON: same rules as GEN FAULT light inhibited: APU speed too low, or GLC opened because EXT PWR or an engine GEN took over
Chapter 11 · Electrical Generation
10
e-books by eatpl.in · © 2026 · Do not copy or distribute
The third generator is driven directly by the APU and produces the same output as an engine generator, so it can replace either engine generator, or both, at any time, on the ground or in flight. On aircraft fitted with a ground and auxiliary power control unit, the G A P C U, that unit regulates its voltage and frequency through the APU electronic control box. With the APU GEN button on, the line contactor closes if the parameters are normal and the external power contactor is open, and the bus tie contactor on a side closes automatically if that engine generator is not operating. The FAULT light means the same as for an engine generator, with the ECAM caution ELEC APU GEN FAULT, but it is inhibited while the APU speed is too low, or when external power or an engine generator simply takes over.
Main AC sources
External power Ground power connector near the nose wheel ; can supply all bus bars A GPCU , or on other aircraft the GAPCU , controls the external power contactor EXT PWR pb: green AVAIL = plugged in, parameters normal; press: blue ON , contactor closes The ON light stays on even when the engine generators take over Outside panel: NOT IN USE (white) GPU may be removed; AVAIL (amber) power available EXT PWR pb (overhead) AVAIL ON AVAIL plugged in, normal AVAIL ON AVAIL + ON aircraft on EXT PWR AVAIL ON ON line contactor closed External power panel (outside, by the connector) NOT IN USE AVAIL white: GPU not supplying, can be removed amber: power available, voltage correct EXT PWR 115 V 400 HZ ELEC page box: shown when external power is available. Amber outside 110 to 120 V or 390 to 410 Hz
Chapter 11 · Electrical Generation
11
e-books by eatpl.in · © 2026 · Do not copy or distribute
External power plugs in near the nose wheel and, like the APU generator, can supply every bus bar. A protection unit, called the G P C U, or the G A P C U on aircraft where one box looks after both ground sources, controls the external power contactor, so it connects only good quality power. In the cockpit, the EXT PWR button shows a green AVAIL light when power is plugged in and its parameters are normal. Press it, the blue ON light comes on, and the contactor closes. Here is a trap: the ON light stays on even after the engine generators take over, because the engine generators simply have priority. Outside, the ground crew have their own panel: a white NOT IN USE light, telling them the unit may be removed, and an amber AVAIL light.
Worked example
From the gate to two engines running Step AC BUS 1 AC BUS 2 Bus tie contactors Lights 1 · GPU plugged in, EXT PWR pressed EXT PWR EXT PWR both closed EXT PWR: AVAIL + ON 2 · APU started, APU GEN pb on EXT PWR EXT PWR both closed EXT PWR has priority while ON 3 · EXT PWR pb pressed again APU GEN APU GEN both closed ON out, AVAIL on 4 · Engine 2 started APU GEN GEN 2 one closed (side 1) GEN 2 takes its own side 5 · Engine 1 started GEN 1 GEN 2 both open APU GEN contactor opens, no FAULT 6 · In flight: GEN 1 fails APU GEN (if running) GEN 2 one closed (side 1) GEN 1 FAULT
Each AC bus always has exactly one source. Step 5: the APU GEN FAULT light is inhibited because an engine generator took over.
Chapter 11 · Electrical Generation
12
e-books by eatpl.in · © 2026 · Do not copy or distribute
Let us apply the priority rules to a real departure. Step one: the ground power unit is plugged in and the crew presses EXT PWR; external power feeds both AC buses through both bus tie contactors. Step two: the APU is started and its generator is selected on, but nothing changes, because external power has priority while its button shows ON. Step three: the crew switches external power off, and the APU generator takes both buses. Step four: engine two is started, and generator two takes AC bus two, while the APU generator keeps AC bus one through one bus tie contactor. Step five: engine one is started, generator one takes its own bus, both bus ties open, and the APU generator is disconnected without a FAULT light. Step six shows the same logic working backwards in flight.
ECAM ELEC page
On the ground: external power or APU ELEC DC BAT DC 1 DC 2 DC ESS AC 1 AC 2 AC ESS BAT 1 28 V 0 A BAT 2 28 V 0 A TR 1 28 V 110 A TR 2 28 V 95 A ESS TR EMER GEN GEN 1 OFF GEN 2 OFF APU GEN EXT PWR 115 V 400 HZ IDG 1 38 °C 39 °C IDG 2 TAT +24 °C SAT +24 °C 06 H 40 GW 64200 KG ELEC DC BAT DC 1 DC 2 DC ESS AC 1 AC 2 AC ESS BAT 1 28 V 0 A BAT 2 28 V 0 A TR 1 28 V 110 A TR 2 28 V 95 A ESS TR EMER GEN GEN 1 OFF GEN 2 OFF APU GEN 38 % 115 V 400 HZ IDG 1 38 °C 39 °C IDG 2 TAT +24 °C SAT +24 °C 06 H 40 GW 64200 KG External power: EXT PWR box, arrows to AC 1 and AC 2 APU generator: APU GEN box, arrows to AC 1 and AC 2 GEN 1 and 2 OFF numbers amber: engines not running One source feeds both AC buses through the bus ties
Chapter 11 · Electrical Generation
13
e-books by eatpl.in · © 2026 · Do not copy or distribute
Here is how steps one and three look on the ECAM ELEC page. On the left, external power is supplying the aircraft. The EXT PWR box shows its voltage and frequency in green, and green arrows go up from it, along the bus tie line, into AC one and AC two. The generator boxes read GEN OFF, and their numbers are amber, because the engines are not running. The APU GEN legend is shown in white without a box, since the APU master switch is off. On the right, the APU is running with its generator on. Now the APU GEN box shows load, voltage and frequency, and it is the APU arrows that go into both AC buses, while the EXT PWR box has gone. The rest of the page, the T Rs and DC buses, is identical.
Back-up sources
The emergency generator Driven by the blue hydraulic system through a hydraulic motor Supplies emergency AC automatically if all main generators fail 5 kVA , three-phase 115/200 V, 400 Hz The RAT extends automatically: AC BUS 1 and 2 lost and speed above 100 kt Its GCU : constant speed, output voltage, EMER GEN line contactor , start-up fuselage skin RAT pump RAT extends > 100 kt blue HYD motor EMER GEN 5 kVA, 400 Hz AC ESS BUS ESS TR DC ESS BUS GCU constant speed GCU: holds a constant speed, controls voltage, controls the EMER GEN line contactor and the start-up
Chapter 11 · Electrical Generation
14
e-books by eatpl.in · © 2026 · Do not copy or distribute
If both AC bus one and AC bus two lose power while the aircraft is faster than one hundred knots, the ram air turbine extends automatically. The airflow spins its turbine, and the RAT pump pressurises the blue hydraulic system. Blue pressure then drives a hydraulic motor coupled to the emergency generator, and the generator spins up. It is much smaller than a main generator: five kilovolt amperes, three-phase, at the same one hundred and fifteen over two hundred volts and four hundred hertz. Its own generator control unit keeps the motor and generator at a constant speed, controls the output voltage, controls the start-up and protects the network through the emergency generator line contactor. Once coupled, it feeds the essential buses: the AC ESS bus directly, and the DC ESS bus through the essential T R.
Back-up sources
The EMER ELEC PWR panel MAN ON (guarded): extends the RAT by hand; EMER GEN couples 3 s after the RAT supplies itAt AUTO : RAT out if AC BUS 1 and 2 are unpowered and speed is above 100 kt Red FAULT (RAT & EMER GEN): EMER GEN not supplying while AC BUS 1 and 2 are unpowered RAT extension and coupling take about 8 s : the batteries bridge the gap GEN 1 LINE : smoke drill, next lessonEMER ELEC PWR EMER GEN TEST GEN 1 LINE SMOKE OFF RAT & EMER GEN FAULT MAN ON A U T O 3 4 2 1 1 MAN ON: RAT out by hand; EMER GEN couples 3 s after the RAT starts supplying it. AUTO: RAT out if AC 1 and 2 are lost above 100 kt 2 FAULT (red): EMER GEN not supplying while AC BUS 1 and 2 are both unpowered 3 EMER GEN TEST: see the next slide 4 GEN 1 LINE: used for the smoke drill (next lesson)
Chapter 11 · Electrical Generation
15
e-books by eatpl.in · © 2026 · Do not copy or distribute
The emergency generator has its own small panel, EMER ELEC PWR. On the right is the guarded MAN ON button. At AUTO, the RAT extends by itself when AC bus one and AC bus two are both unpowered and the speed is above one hundred knots, and the emergency generator is connected as soon as its voltage and frequency are within tolerance. Pressing MAN ON extends the RAT by hand, and the generator couples three seconds after the RAT starts supplying it. Next to it is a red FAULT light, which means the emergency generator is not supplying power although both main AC buses are dead. Expect a short gap: extending the RAT and coupling the generator takes about eight seconds, and during that time the batteries power the essential network. The GEN 1 LINE button comes in the next lesson.
Back-up sources
EMER GEN TEST and the EMER GEN box Press and hold, with normal AC: EMER GEN driven hydraulically if the blue electric pump runs AC ESS and DC ESS go on the EMER GEN; the shed buses are not powered ELEC page shown automatically, on the ground only With only the batteries: the static inverter powers the AC ESS BUS EMER GEN box: amber outside 110 to 120 V or 390 to 410 Hz ; no values with its contactor open EMER GEN TEST press and hold AC normal buses powered EMER GEN driven hydraulically if the blue electric pump runs AC ESS + DC ESS on the EMER GEN (shed buses not powered) ELEC page shown (ground only) Only the batteries powered The static inverter powers the AC ESS BUS (inverter test) EMER GEN 116 V 400 HZ Amber below 110 or above 120 V, or below 390 or above 410 Hz. No values while its line contactor is open.
Chapter 11 · Electrical Generation
16
e-books by eatpl.in · © 2026 · Do not copy or distribute
The EMER GEN TEST button, also guarded, lets maintenance or the crew check the emergency chain without extending the RAT. Press and hold it while the normal AC buses are powered, and the emergency generator is driven by blue hydraulic pressure, provided the blue electric pump is running. The AC essential and DC essential buses are transferred to it, but the shed parts of those buses are not powered, exactly as in a real emergency. On the ground, the ECAM shows the ELEC page by itself. If only the batteries are supplying the aircraft, the same button tests the static inverter instead, which then powers the AC essential bus. On the ELEC page the emergency generator box shows voltage and frequency, amber outside the same limits as the main generators, and blank while its line contactor is open.
Back-up sources
The static inverter Turns BAT 1 DC into 1 kVA of single-phase 115 V, 400 Hz AC Feeds part of the AC ESS BUS (and the AC STAT INV BUS) Above 50 kt : on automatically if only the batteries supply the aircraft, whatever the BAT pbs Below 50 kt : on only if both BAT 1 and BAT 2 pbs are at AUTO ELEC page: STAT INV box during its test, or with the ELEC pb when the ESS buses are on batteries Only the batteries supply the aircraft Speed > 50 kt? yes no BAT 1 and BAT 2 pbs both at AUTO? yes no Inverter OFF STATIC INVERTER ON BAT 1 DC into 1 kVA, single-phase 115 V 400 Hz Feeds part of the AC ESS above 50 kt: whatever the BAT pb positions
Chapter 11 · Electrical Generation
17
e-books by eatpl.in · © 2026 · Do not copy or distribute
The static inverter is the last line of defence for AC. It takes DC from battery one and turns it into one kilovolt ampere of single-phase, one hundred and fifteen volt, four hundred hertz AC, which feeds part of the AC essential bus. Its logic depends on speed. Above fifty knots, if only the batteries are supplying the aircraft, it comes on automatically, whatever the position of the battery buttons. Below fifty knots it comes on only if both BAT one and BAT two buttons are at AUTO. Notice how small it is: one kilovolt ampere against ninety for a main generator, so only a few essential AC users are kept. On the ELEC page a STAT INV box with voltage and frequency appears during its test, or when the crew calls the page while the essential buses are on batteries.
DC sources
The transformer rectifiers TR 1 and TR 2 : up to 200 A eachESS TR , identical: powers the DC ESS from the EMER GEN if all main generators fail, or if TR 1 or TR 2 fails Each TR controls its own contactor by internal logic On some aircraft a fourth, TR Ent , feeds the DC BUS Ent for in-flight entertainment ELEC page: TR current amber at 5 A or less , voltage amber outside 25 to 31 V TR 1 (2) on the ELEC page TR 1 28 V 150 A normal TR 1 28 V 4 A current 5 A or less TR 1 0 V 0 A V and A both amber: legend amber Voltage amber below 25 V or above 31 V. ESS TR ESS TR 28 V 130 A supplying ESS TR contactor open Same colour rules as TR 1 and 2. In normal flight the ESS TR is idle: just its name. Each TR opens its own contactor on overheat or minimum current.
Chapter 11 · Electrical Generation
18
e-books by eatpl.in · © 2026 · Do not copy or distribute
DC comes from transformer rectifiers, which take AC in and give twenty eight volts DC out. There are two main ones, T R one and T R two, each able to deliver up to two hundred amps. A third, identical unit is the essential T R. It is normally idle, and it powers the DC essential bus from the emergency generator when all the main generators have failed, or from the AC side when T R one or T R two fails. Each T R decides for itself when to open its contactor, using internal logic. Some aircraft have a fourth, the entertainment T R, which feeds a DC bus dedicated to the in-flight entertainment system. On the ELEC page, the current turns amber at five amps or less, and the voltage outside twenty five to thirty one volts.
DC sources
The two batteries Two main batteries, each 23 Ah Permanently connected to their HOT BUS 1 and HOT BUS 2 Each has a battery charge limiter (BCL) : it monitors charging and controls the battery contactor Connected to the DC BAT BUS only when they need charging ; then disconnected again So in normal flight the batteries are disconnected most of the time DC BAT BUS BAT 1 23 Ah HOT BUS 1 BCL 1 BAT 2 23 Ah HOT BUS 2 BCL 2 battery contactor: open when charged Batteries always feed their hot bus. The BCL closes the contactor to charge them (and for APU start or emergencies).
Chapter 11 · Electrical Generation
19
e-books by eatpl.in · © 2026 · Do not copy or distribute
The A320 has two main batteries of twenty three ampere hours each. In theory that is twenty three amps for one hour, so they are a reserve, not a power station. Each battery is wired permanently to its own hot bus, which is why hot bus equipment stays live even with every switch off. Between each battery and the DC BAT bus sits a battery contactor, controlled by the battery charge limiter, the B C L. Watch the scene. The battery voltage has dropped a little, so the B C L closes the contactor and charging starts: current flows from the DC BAT bus into the batteries and the voltage rises. As the batteries fill up, the charge current tapers, and the limiter opens the contactor again. That is why, in normal flight, the batteries are disconnected most of the time.
DC sources
When the BCL connects the batteries APU start : MASTER SW ON and N below 95 % (max 3 min with the EMER GEN running)Charging : battery below 26.5 V ; on ground at once , in flight after 30 min ; ends below 4 A Emergency : AC BUS 1 and 2 lost below 100 kt (EMER GEN not supplying)No main AC, no EMER GEN: BAT 1 feeds the AC STAT INV BUS, and the AC ESS above 50 kt; BAT 2 feeds the DC ESS BCL closes the battery contactor when: APU start MASTER SW ON and N below 95 % 3 min max. with EMER GEN running Charging battery below 26.5 V: on ground at once, in flight after 30 min; stops below 4 A Emergency AC BUS 1 and 2 lost below 100 kt (EMER GEN not supplying) No AC BUS 1 or 2 and no EMER GEN: BAT 1: AC STAT INV BUS (via the inverter), and the AC ESS BUS above 50 kt BAT 2: DC ESS BUS
Chapter 11 · Electrical Generation
20
e-books by eatpl.in · © 2026 · Do not copy or distribute
With the BAT buttons at AUTO, the charge limiter connects its battery to the DC BAT bus in three cases. First, for an APU start: master switch on and APU speed below ninety five per cent, and if the emergency generator is running, that connection is limited to three minutes. Second, for charging: when the battery voltage falls below twenty six point five volts. On the ground this happens at once; in flight it waits thirty minutes. Charging ends when the charge current falls below four amps. Third, in an emergency, when AC bus one and two are lost below one hundred knots and the emergency generator is not supplying. And if there is neither main AC nor the emergency generator, battery one feeds the AC static inverter bus, plus the AC essential bus above fifty knots, while battery two feeds the DC essential bus.
DC sources
The BAT pushbuttons and the cut-off AUTO (lights out): the BCL controls the contactor automaticallyOFF : BCL not operating, contactor open; the DC BAT BUS is still supplied and the hot buses stay live Amber FAULT + ECAM: charging current out of limits; the contactor opens Automatic cut-off on the ground: on ground, pbs at AUTO, EXT PWR and GEN cut off, battery voltage low: contactors openReset: BAT pb OFF then AUTO BAT 1 (2) pb FAULT OFF AUTO lights out FAULT OFF OFF BCL not operating FAULT OFF FAULT charge current out of limits AUTO: the BCL connects the battery to the DC BAT BUS for APU start, for charging, and below 100 kt with AC BUS 1 and 2 lost OFF: contactor open; DC BAT BUS still fed, hot buses live FAULT: contactor opens, with an ECAM caution
Chapter 11 · Electrical Generation
21
e-books by eatpl.in · © 2026 · Do not copy or distribute
Now the BAT buttons themselves. At AUTO, lights out, the charge limiter is in control and connects or disconnects the battery as we have just seen. At OFF, the limiter stops working and the battery contactor stays open. The DC BAT bus is still supplied from the T Rs, and the hot buses are still live, because the batteries are wired to them permanently. The amber FAULT light, with an ECAM caution, means the charging current is outside its limits, and the contactor opens to protect the battery. One more protection: on a parked aircraft, an automatic cut-off stops the batteries going flat. If the aircraft is on the ground, the buttons are at AUTO, the main supply from external power and generators is cut, and the battery voltage is low, the contactors open. To reset them, select OFF, then AUTO.
DC sources
Battery indications on the ELEC page BAT box: voltage and current ; legend amber with amber V and A, or a BAT FAULT Voltage amber below 25 V or above 31 V ; current amber when discharging above 5 A Arrow: green charging above 1 A, amber discharging above 1 A, plain line below 1 A, nothing if the contactor is open DC BAT bar amber at 25 V or less pb OFF: box reads BAT OFF Battery indications BAT 1 28 V 0 A normal BAT 1 24 V 12 A below 25 V and discharging > 5 A BAT 1 OFF pb OFF Arrow between BAT and DC BAT (contactor closed) charging, more than 1 A discharging, more than 1 A less than 1 A contactor open: no line DC BAT DC BAT amber at 25 V or less Current figure amber when discharging above 5 A.
Chapter 11 · Electrical Generation
22
e-books by eatpl.in · © 2026 · Do not copy or distribute
On the ELEC page each battery has a box with its voltage and current. The voltage turns amber below twenty five or above thirty one volts, and the current turns amber when the battery is discharging at more than five amps. If both are amber, or there is a BAT FAULT alert, the BAT legend turns amber too. Between the box and the DC BAT bar there is a little symbol. A green arrow pointing into the battery means it is charging at more than one amp. An amber arrow pointing out means it is discharging at more than one amp, which in flight should make you ask why. A plain line means the contactor is closed but less than one amp flows, and no line at all means the contactor is open. Finally, the DC BAT bar turns amber at twenty five volts or less.
Summary table
Every source at a glance Source Output Controlled by Normally feeds GEN 1, GEN 2 (IDG) 90 kVA, 3-phase 115/200 V 400 Hz GCU 1, GCU 2 (GLC) AC BUS 1, AC BUS 2 APU GEN same as an engine GEN GAPCU (where fitted) via the APU ECB either or both AC buses External power ground power unit GPCU or GAPCU (EXT PWR contactor) the whole network on the ground EMER GEN 5 kVA, 3-phase 115/200 V 400 Hz its GCU (blue hydraulic drive) AC ESS, and DC ESS via the ESS TR Static inverter 1 kVA, single-phase 115 V 400 Hz automatic logic (50 kt) part of the AC ESS, from BAT 1 TR 1, TR 2, ESS TR 28 V DC, up to 200 A internal logic (own contactor) DC BUS 1, DC BUS 2, DC ESS BAT 1, BAT 2 23 Ah each BCL (battery contactor) hot buses; DC BAT BUS when charging
Ratings compared: the emergency generator is about 6 % of one main generator, the static inverter about 1 %.
Chapter 11 · Electrical Generation
23
e-books by eatpl.in · © 2026 · Do not copy or distribute
Here is every source on one page, which is a good table to learn by heart. The engine generators give ninety kilovolt amperes each, under their own generator control units, and normally feed AC bus one and two. The APU generator has the same output and can feed either or both buses. External power can feed the whole aircraft on the ground. The emergency generator gives only five kilovolt amperes, about six per cent of one main generator, and feeds the essential buses. The static inverter gives just one kilovolt ampere from battery one, about one per cent. The three T Rs give twenty eight volts DC at up to two hundred amps each. And the two batteries of twenty three ampere hours feed the hot buses permanently, and the DC BAT bus when they need charging.
Summary
Electrical generation in one page System 3-phase 115/200 V 400 Hz AC; 28 V DC from TRs. Generators never in parallel.
Priorities Engine GENs first, then EXT PWR (pb ON), then APU GEN. One GEN feeds all but DC BUS Ent.
IDG and GEN IDG FAULT: oil above 180 °C or low pressure; disconnect is final. GEN FAULT: GCU trip or GLC open.
EMER GEN Blue hydraulics, 5 kVA. RAT auto: AC 1 + 2 lost above 100 kt. About 8 s on batteries.
Static inverter BAT 1 to 1 kVA AC. Auto above 50 kt; below 50 kt only with both BAT pbs at AUTO.
Batteries 23 Ah, always on the hot buses. BCL: APU start, charging below 26.5 V, emergency below 100 kt.
Chapter 11 · Electrical Generation
24
e-books by eatpl.in · © 2026 · Do not copy or distribute
Let us close the generation lesson. The A320 runs on three-phase AC at one hundred and fifteen over two hundred volts and four hundred hertz, with twenty eight volts DC made by transformer rectifiers, and it never parallels its generators. The engine generators have priority, then external power when its button is on, then the APU generator, and a single generator can carry almost everything. The I D G FAULT light is about oil temperature and pressure, and disconnection is final for the flight; the GEN FAULT light is about the generator control unit and the line contactor. The emergency generator runs on blue hydraulic power from the RAT, with about eight seconds on batteries while it comes on line. The static inverter makes a little AC from battery one. And the batteries live on the hot buses, joining the DC BAT bus only when the charge limiter says so.