A320 Aircraft Systems · Chapter 33
Engine Start, Ignition, Reversers and Indications Thrust reversers and their protections, the ignition system, automatic and manual starts, cranking, and every engine indication on the E/WD and the ENGINE page.
5 10 19. 5 AVAIL 415 5 10 4. 0 160 N1 % EGT °C N2 % FF KG/H 58. 2 300 24. 0 0 FLX 85.3 % 58°C ENG MASTER 1 ON OFF ENG 1 FIRE FAULT 1 MASTER 2 ON OFF ENG 2 FIRE FAULT 2 MODE NORM CRANK IGN START © 2026 eatpl.in. For the personal study of eatpl.in students only. Do not copy or distribute.
e-books by eatpl.in · © 2026 · Do not copy or distribute
In the last lesson we built the engine and learned to control its thrust. Now we operate it. We begin at the back of the nacelle with the thrust reversers: how they deploy, what must be true before they can, and how the FADEC protects you if one moves when it should not. Then the ignition system, and the start: the automatic start that you will do every day, the protections that watch over it, the manual start for when things go wrong, and dry and wet cranking. Finally we read every engine indication on the engine and warning display and the ENGINE system page, with the numbers examiners like to ask. Once again we will compare the CFM56 and the LEAP wherever they differ.
Engine operation
Our route through ATA 70, part two ENG MASTER 1 ON OFF ENG 1 FIRE FAULT 1 MASTER 2 ON OFF ENG 2 FIRE FAULT 2 MODE NORM CRANK IGN START ENG MAN START 1 ON 2 ON 5 10 70. 0 REV 735 5 10 70. 0 REV 742 N1 % EGT °C N2 % FF KG/H 95. 1 2580 95. 2 2600 ENGINE F.USED KG 1530 1560 OIL QT PSI 15. 0 40 16. 0 45 °C 95 100 VIB N1 N2 0.8 1.1 0.9 1.2 IGN PSI A 34 Reversers Doors or sleeves, green and yellow, deployment logic, idle protection, TCMA.
Ignition Two igniters per engine, use during starts, continuous ignition, quick relight.
Starting ENG panel, MAN START, automatic start, protections, manual start, cranking.
Indications E/WD engine section, N1, EGT, N2, FF, ENGINE page and memos.
Chapter 33 · Engine Start, Ignition, Reversers and Indications
2
e-books by eatpl.in · © 2026 · Do not copy or distribute
Here is the plan for the second half of chapter seventy. We start with the thrust reversers: the two designs in our fleet, which hydraulic system powers each one, the conditions that must all be met before a reverser can deploy, and the protections the FADEC provides, including thrust control malfunction accommodation. Next the ignition system: two igniters per engine, which ones are used during a start, and continuous ignition. Third, starting: the ENG panel on the pedestal, the manual start buttons on the overhead, the automatic start step by step, its protections, the manual start and cranking. Finally the indications: the engine part of the engine and warning display, the ENGINE system page and the engine memos.
Part 1 · Thrust reversers
Two reversers, two hydraulic systems Reverse thrust comes from deflecting the fan airstream forward Green powers the ENG 1 reverser, yellow the ENG 2 reverserEach reverser is controlled by its own FADEC ; both channels control and monitor The two reversers are independent of each other Full deployment takes about 2 seconds ENG 1 REV GREEN ENG 2 REV YELLOW Each reverser: its own FADEC, independent of the other
Chapter 33 · Engine Start, Ignition, Reversers and Indications
3
e-books by eatpl.in · © 2026 · Do not copy or distribute
Reverse thrust on the A320 comes only from the fan stream: the reverser deflects the cold bypass air forwards. Both designs in our fleet are hydraulically powered, and the split is easy to remember: the green system powers the reverser on engine one, and the yellow system powers the reverser on engine two. Each reverser is controlled by the FADEC of its own engine, and each FADEC channel performs both control and monitoring. The two engines' reverser systems are completely independent of each other, so a fault on one does not affect the other. A full deployment takes about two seconds, a little under two seconds on the CFM. Keep the hydraulic link in mind: if you lose green, you lose the engine one reverser.
CFM56-5B
Pivoting door reverser Four pivoting blocker doors per engine deflect the fan airEach door has its own hydraulic jack ; doors move independently (not synchronised) 4 actuators, 4 latches , door position switchesHCU : pressurises the reverser, regulates door speed, supplies the actuatorsA hydraulic shut-off valve lets pressure reach the HCU; deployment in under 2 s STOWED DEPLOYED fan air goes aft fan air turned forward
Chapter 33 · Engine Start, Ignition, Reversers and Indications
4
e-books by eatpl.in · © 2026 · Do not copy or distribute
On the CFM fifty six, the reverser is built into the nacelle as four pivoting blocker doors. Watch the fan air flowing aft. When the reverser is commanded to deploy, each door pivots about its hinge: its rear edge swings into the fan duct and blocks it, and its front edge opens outward, so the air is turned forward. Each door is moved by its own hydraulic jack, and the doors are not synchronised; each moves on its own. The system on each engine has four actuators, four latches and door position switches. A hydraulic control unit pressurises the reverser system, regulates the door speed and supplies the actuators, and a hydraulic shut-off valve upstream lets pressure through to it. The whole movement takes less than two seconds.
LEAP-1A
Translating sleeve reverser Translating sleeves move aft; blocker doors close the fan duct; air exits through cascades 4 hydraulic actuators , mechanically synchronised by flexible shafts; each with a primary lock and an LVDT 5 latches and sleeve position switchesICU allows pressurisation; DCU directs pressure to the actuatorsTertiary lock : electrically unlocked on the deploy command (no hydraulics)STOWED DEPLOYED sleeve covers the cascades sleeve aft: air out through cascades
Chapter 33 · Engine Start, Ignition, Reversers and Indications
5
e-books by eatpl.in · © 2026 · Do not copy or distribute
The LEAP uses a different design: translating sleeves. When deployment is commanded, the translating sleeve slides aft. As it moves, pivoting blocker doors swing down and close the fan duct, and the fan air is forced out through the cascades, which turn it forward. Four hydraulic actuators drive the sleeves. They are mechanically synchronised by flexible shafts, and each has a primary lock and a linear variable differential transducer that tells the FADEC its position. There are five latches and position switches on the sleeves. An isolation control unit allows the reverser hydraulics to be pressurised, a directional control unit supplies the actuators, and a tertiary lock, which is electrical and not hydraulic, unlocks when deployment is commanded. Total time, about two seconds.
Deployment logic
All conditions together FADEC channel with its own TLA reverse signal EIVMU / EIU channel TLA reverse (LEAP-1A) LGCIU 1 and 2 left AND right main gear compressed SEC 1, 2 or 3 TLA reverse from at least one SEC AND Reverser deploys green (ENG 1) or yellow (ENG 2) pressure to the actuators thrust held at reverse idle until fully deployed LEAP-1A: the SECs, the EIVMU/EIU and the FADEC use different TLA sensors, so one faulty sensor cannot deploy a reverser CFM56: FADEC + LGCIUs + SEC The FADEC holds the engine at reverse idle until the reverser is fully deployed; only then does more reverse thrust come.
Chapter 33 · Engine Start, Ignition, Reversers and Indications
6
e-books by eatpl.in · © 2026 · Do not copy or distribute
A reverser opening in flight would be very dangerous, so several independent conditions must all be true together. First, a FADEC channel must see its own thrust lever reverse signal. On the LEAP aircraft, a channel of the engine interface unit must also command it, triggered by the reverse signal. Second, both the left and the right main gear must be compressed, signalled by the landing gear computers. Third, at least one spoiler elevator computer must also see the thrust lever in reverse. On the LEAP, the SECs, the interface units and the FADEC deliberately use different sensors for the lever angle, so one faulty sensor cannot deploy a reverser by itself. Finally, until the reverser is fully deployed, the FADEC holds the engine at reverse idle.
Protection
Idle protection and assisted stow CFM: unwanted deployment : thrust to idle above 15 % deployed (decreasing from 10 %) CFM: unwanted stowage in reverse: reverse thrust to idle below 78 % (decreasing from 90 %) LEAP: idle if reverse not selected and the sleeves are unstowed , or a door unstowed / position unknown with DCU pressure LEAP ground assisted stow : one primary lock unlocked and levers forward → stow and lock Amber REV on the E/WD when a reverser is unlocked Inadvertent deployment (stow commanded) thrust idle 0 25 50 75 100 reverser position, % deployed 10 % 15 % above 15 %: forward thrust at idle Inadvertent stowage (deploy commanded) thrust idle 0 25 50 75 100 reverser position, % deployed 78 % 90 % below 78 %: reverse thrust at idle
Chapter 33 · Engine Start, Ignition, Reversers and Indications
7
e-books by eatpl.in · © 2026 · Do not copy or distribute
The FADEC automatically limits the thrust to idle if a reverser moves when it should not. On the CFM, if the reverser starts deploying while it is commanded stowed, thrust begins to fall as soon as it reaches ten per cent deployed, and is at idle once it is past fifteen per cent. The opposite case is a reverser that starts stowing while reverse is selected. Reverse thrust begins to fall below ninety per cent deployed and is at idle below seventy eight per cent. On the LEAP, idle protection triggers when reverse is not selected and the sleeves are detected unstowed, or a door is unstowed with pressure downstream of the directional control valve. And the LEAP has a ground assisted stow: if a primary lock unlocks on the ground with the levers forward, the FADEC drives the reverser back to stowed and locks it.
LEAP-1A protection
Thrust control malfunction accommodation Protects against uncontrollable high thrust : thrust above the commanded value Active only on the ground , during take-off and approach In flight (approach, flare): fuel flow cut back through the FMU On the ground, levers at idle or reverse: engine shut down by the FMU HPSOV A thrust control malfunction lights the ENG FAULT light with an ECAM caution Thrust above the commanded value? TCMA active: on the ground, take-off and approach In flight take-off or approach / flare: fuel flow cut back through the FMU On the ground levers at idle or in reverse: engine shut down by the FMU HPSOV FIRE FAULT ENG FAULT light (pedestal) ECAM caution with the FAULT light thrust control malfunction
Chapter 33 · Engine Start, Ignition, Reversers and Indications
8
e-books by eatpl.in · © 2026 · Do not copy or distribute
Thrust control malfunction accommodation, TCMA for short, is a LEAP FADEC protection against an engine that delivers more thrust than commanded and will not come back. It is only active when such an over-thrust would be most dangerous: on the ground, during take-off and during approach. When it detects an over-thrust in flight, during approach or flare, it activates a cutback and reduces the fuel flow through the fuel metering unit. On the ground, if the thrust levers are at idle or in reverse, it goes further and shuts the engine down by closing the high pressure shut-off valve in the fuel metering unit. A thrust control malfunction is also one of the reasons for the amber FAULT light on the ENG panel, together with an ECAM caution.
Part 2 · Ignition
Two igniters per engine For starting on the ground and relighting in flight Two identical, independent circuits : igniters A and B Normally controlled by FADEC channel A and channel B ; each channel can fire both igniters Igniter A: AC ESS , switching to the STAT INV bus bar once the static inverter is operative Igniter B: AC normal supply FADEC Channel A Channel B IGNITER A IGNITER B AC ESS (STAT INV bus once the static inverter is operative) AC NORM Two identical, independent circuits per engine each FADEC channel can fire both igniters annular combustion chamber: two igniters
Chapter 33 · Engine Start, Ignition, Reversers and Indications
9
e-books by eatpl.in · © 2026 · Do not copy or distribute
The ignition system is used for starting on the ground and for relighting in flight. Each engine has two identical, independent circuits, igniter A and igniter B, both in the annular combustion chamber. Normally FADEC channel A and channel B control them, but either channel can fire both igniters, so the loss of a channel does not cost you an igniter. The power supplies are separate too. Igniter A comes from the essential AC supply, and as soon as the static inverter is operative it is fed from the static inverter bus bar, which keeps it alive in the emergency electrical configuration. Igniter B comes from the normal AC supply. So with total loss of normal AC, you still have igniter A on each engine for a relight.
Ignition during starts
Which igniter, and when? CFM56-5B LEAP-1A Automatic ground start, first attempt One igniter, alternated by the FADEC between starts; on at N2 16 %, off at 50 % One igniter, alternated; on at about N2 20 %, off at 55 % If the attempt fails Next attempt with both igniters Second attempt: same igniter; third attempt: both igniters Cold engine, airport above 10 000 ft (some aircraft) One igniter, then the second once ignition is detected — Manual start Both igniters from ENG MASTER ON; off at about N2 50 % Both igniters from ENG MASTER ON; off at about N2 55 % In-flight start Both igniters from ENG MASTER ON Both igniters from ENG MASTER ON
Alternating the igniters on successive starts means a failed igniter is found on the ground.
Chapter 33 · Engine Start, Ignition, Reversers and Indications
10
e-books by eatpl.in · © 2026 · Do not copy or distribute
Let us see which igniters the FADEC uses. On an automatic ground start, the first attempt uses only one igniter, and the FADEC alternates the igniter and the channel from one start to the next. On the CFM the ignition comes on at sixteen per cent N2 and goes off at fifty. On the LEAP it comes on at about twenty and goes off at fifty five. If the attempt fails, the CFM tries again with both igniters; the LEAP tries a second time with the same igniter and only uses both on the third attempt. Some CFM aircraft, starting a cold engine at an airport above ten thousand feet, fire one igniter and add the second once ignition is detected. In a manual start or an in-flight start, both igniters are always used.
Continuous ignition
Continuous ignition and quick relight Manual: in flight, ENG MODE to IGN/START with the engine running (LEAP both igniters; CFM one, both if it fails) On the ground after a start: NORM then back to IGN/START Automatic: flame-out detected , or the second automatic start attempt failed CFM also: engine running with EIU failure, flame-out or ignition delay during start Quick relight : MASTER OFF then ON while windmilling → automatic relight; memo IGNITION in greenENG MASTER 1 ON OFF ENG 1 FIRE FAULT 1 MASTER 2 ON OFF ENG 2 FIRE FAULT 2 MODE NORM CRANK IGN START ENG MODE at IGN/START, engine running: continuous ignition Automatic flame-out detected 2nd automatic start attempt failed (LEAP) CFM, engine running: EIU failure, flame-out or ignition delay at start Memo display IGNITION green: continuous ignition on Quick relight: MASTER OFF then ON while windmilling: FADEC relights automatically
Chapter 33 · Engine Start, Ignition, Reversers and Indications
11
e-books by eatpl.in · © 2026 · Do not copy or distribute
Continuous ignition keeps the igniters firing to maintain combustion when the engine is running. Manually, you select it in flight by turning the ENG MODE selector to IGN START with the engines running. On the LEAP both igniters fire; on the CFM only one, and if it fails both are selected automatically. On the ground after a start the ignition cuts off by itself, so to get continuous ignition you must turn the selector to NORM and then back to IGN START. The FADEC also selects it automatically, when it detects a flame-out, or after a second failed automatic start attempt. And if a master lever is accidentally cycled OFF and ON within the windmilling quick relight envelope, the FADEC attempts a relight automatically, whatever the selector position. The green IGNITION memo shows it is on.
Part 3 · Starting
Starter and start valve Air turbine starter on the gearbox, fed through a start valve Air from the pneumatic system (APU, ground cart or the other engine) The FADEC opens the valve electrically , but it needs bleed pressure to open On the ground, if electrical control fails: a manual handle opens the valve The FADEC runs the sequence: start valve, igniters, HP fuel valve PNEUMATIC APU · cart · other eng START VALVE FADEC, electrical; needs bleed pressure to open manual handle AIR TURBINE STARTER ACCESSORY GEARBOX turns the HP rotor (N2)
Chapter 33 · Engine Start, Ignition, Reversers and Indications
12
e-books by eatpl.in · © 2026 · Do not copy or distribute
The starting system is simple: an air turbine starter and a start valve. Bleed air from the pneumatic system, which on the ground usually means the APU, sometimes a ground cart or the other engine, waits at the start valve. The FADEC opens the valve electrically, but the valve needs bleed pressure to actually move. Air spins the starter, which turns the accessory gearbox and with it the HP rotor, so N2 turns and rises. At about sixteen per cent the ignition comes on, and at twenty two the HP fuel valve opens and the engine lights up. At fifty per cent the start valve closes and the starter drops out, and the engine accelerates on its own to idle. If the valve's electrical control fails on the ground, a mechanic can open it with a manual handle.
ENG MASTER 1 and 2 : ON starts the engine (with MODE at IGN/START), OFF shuts it down or aborts the startENG MODE selector : CRANK, NORM , IGN/STARTIGN/START: begins the automatic or manual start (MASTER still OFF); fires the igniters in flight as required FIRE light: fire detected in that engineFAULT (amber): HP fuel valve position abnormal, automatic start aborted, or thrust control malfunctionENG MASTER 1 ON OFF ENG 1 FIRE FAULT 1 MASTER 2 ON OFF ENG 2 FIRE FAULT 2 MODE NORM CRANK IGN START FAULT (amber) + ECAM caution: HP fuel shut-off valve position abnormal automatic start aborted thrust control malfunction FIRE (red): fire detected in that engine
Chapter 33 · Engine Start, Ignition, Reversers and Indications
13
e-books by eatpl.in · © 2026 · Do not copy or distribute
This is the ENG panel on the pedestal, behind the thrust levers. The two master levers are the engine on and off switches. With the mode selector at IGN START, setting a master lever ON starts the automatic start of that engine, or the manual start if its manual start button is pressed. Setting a master lever OFF shuts the engine down, or aborts a start in progress. The rotary mode selector has three positions: CRANK, NORM and IGN START. NORM is the normal position. IGN START is used to begin a start, before the master lever goes on, and in flight to fire the igniters when needed. Below each master lever are two lights: the red FIRE light, and the amber FAULT light, which means an abnormal HP fuel valve position, an aborted automatic start, or a thrust control malfunction.
Overhead
ENG MAN START and cranking One per engine on the overhead; ON shows a blue light MODE IGN/START + MAN START ON : begins the manual start MODE CRANK + MAN START ON, MASTER OFF: dry crank , no fuel, no ignition: blows out fuel vapour after a failed ground start MODE CRANK + MAN START ON, MASTER ON: wet crank (maintenance) Off: aborts a manual start (MASTER OFF), or stops a dry crank ENG MAN START 1 ON 2 ON pb 1 ON (blue), pb 2 off Normally off (automatic starts do not use it) ON: blue light Off: no light MODE MASTER MAN START ON MAN START off IGN/START OFF manual start begins manual start aborted CRANK OFF dry crank dry crank stops CRANK ON wet crank (maint.) —
Chapter 33 · Engine Start, Ignition, Reversers and Indications
14
e-books by eatpl.in · © 2026 · Do not copy or distribute
The ENG MAN START pushbuttons are on the overhead panel, one per engine, and they stay off for normal automatic starts. Pressed on, they show a blue ON light, and their meaning depends on the mode selector. With the selector at IGN START, pressing the button on begins a manual start of that engine. With the selector at CRANK and the master lever off, it begins a dry crank: the starter turns the engine with no fuel and no ignition, to ventilate it and remove fuel vapour after an unsuccessful start on the ground. Setting the button back to off stops the crank. With the selector at CRANK and the master lever on, you get a wet crank, which adds fuel, and that is a maintenance procedure. Releasing the button with the selector at IGN START and the master lever still off aborts a manual start.
Automatic start
Set-up and the first step Initial set-up: MASTER OFF , MODE NORM , MAN START off First step: MODE to IGN/START The ENGINE page appears on the SD, and all engine parameters are available The pack valves close , so all the bleed air goes to the starter No MASTER ON within 30 s : the pack valves reopen ENG MASTER 1 ON OFF ENG 1 FIRE FAULT 1 MASTER 2 ON OFF ENG 2 FIRE FAULT 2 MODE NORM CRANK IGN START MODE → IGN/START Initial set-up MASTER OFF MODE NORM MAN START off then turn MODE to IGN/START ENGINE F.USED KG 0 0 OIL QT PSI 15. 0 0 15. 5 0 °C 18 18 VIB N1 N2 0.0 0.0 0.0 0.0 IGN PSI 36 36 ENGINE page on the SD all engine parameters available pack valves close no MASTER ON within 30 s: pack valves reopen
Chapter 33 · Engine Start, Ignition, Reversers and Indications
15
e-books by eatpl.in · © 2026 · Do not copy or distribute
The automatic start begins from a fixed set-up: both master levers OFF, the mode selector at NORM, and the manual start buttons off. The first step is to turn the mode selector to IGN START. Three things happen. The ENGINE page appears automatically on the system display. All the engine parameters become available. And the pack flow control valves close, so that the air conditioning does not take bleed air that the starter needs. If you do not set a master lever ON within thirty seconds, the pack valves open again by themselves, so the passengers are not left without air if the start is delayed. The start itself has not begun yet: the selector only arms it.
Automatic start
The second step: ENG MASTER ON 10 20 30 40 50 60 N2 % time after ENG MASTER ON (illustrative) 16 % ignition ON 22 % HP fuel valve opens 50 % start valve closes · ignition OFF MASTER ON: LP fuel valve and start valve open Ground automatic start N2 CFM56-5B LEAP-1A ignition on 16 % 15 % HP fuel valve 22 % 20 % ignition off 50 % 55 % start valve shut 50 % 63 % packs reopen if no 30 s 60 s other start within In flight: ignition immediately; HP valve at 15 % (CFM) or 20 % (LEAP) Third step: the start is complete, set the ENG MODE selector back to NORM.
Chapter 33 · Engine Start, Ignition, Reversers and Indications
16
e-books by eatpl.in · © 2026 · Do not copy or distribute
The second step is the ENG MASTER lever ON. The LP fuel valve and the start valve open, and N2 begins to rise. On the CFM on the ground, ignition comes on at sixteen per cent N2, and the HP fuel valve opens at twenty two, so fuel reaches the burners and the engine lights up. At fifty per cent the start valve closes, the ignition stops, and if you do not start the other engine within thirty seconds, the pack valves reopen. The LEAP numbers are different: ignition at fifteen, HP valve at twenty, ignition off at fifty five, start valve closed at sixty three, and sixty seconds before the packs reopen. In flight the ignition comes on immediately. The third step is simply to return the mode selector to NORM once both engines are running.
Automatic start
Protections and the abort sequence FADEC detects: hot start, hung start, stall, failed light-up, low start air pressure, starter time exceeded, lever not at idle LEAP adds: EGT overlimit, failed bowed rotor protection , starter shaft shear It lights FAULT and names the fault on the ECAM Ground abort: HP valve and start valve close , ignition off , automatic dry crank , further attempts To stop a start yourself (when ECAM asks, after confirmation): MASTER OFF closes LP and HP valves, ignition off, start valve closed FADEC detects hot start hung start (CFM) stall failed light-up low start air pressure starter time exceeded thrust lever not at idle LEAP also: EGT overlimit, bowed rotor protection failed, starter shaft shear Abort on the ground HP fuel valve closes start valve closes ignition off automatic dry crank (removes fuel vapour) further attempts under FADEC control FIRE FAULT ECAM message identifies the start fault
Chapter 33 · Engine Start, Ignition, Reversers and Indications
17
e-books by eatpl.in · © 2026 · Do not copy or distribute
During an automatic start the FADEC has full authority, and it watches for trouble: a hot start, a hung start, a stall, a failed light-up, low start air pressure, the starter running too long, or a thrust lever not at idle. The LEAP also checks EGT overlimit, the bowed rotor protection and starter shaft shear. When it finds one, the FAULT light comes on and the ECAM tells you what it is. On the ground it runs the abort sequence by itself: it closes the HP fuel valve and the start valve, switches off the ignition, then dry cranks the engine automatically to blow out the fuel vapour, and controls any further attempts. If the ECAM asks you to interrupt a start, after confirmation you set the master lever OFF, which closes the LP and HP fuel valves, stops the ignition and closes the start valve.
LEAP-1A
Bowed rotor motoring and in-flight starts After shutdown a hot core can bow ; turning it fast too early can make it rub LEAP: pre-start motoring (dry cranking) for up to 60 s on every ground start and crank During motoring the FADEC holds N2 at about 30 % , below the bowed rotor critical speed Motoring time depends on the engine's residual heat and vibration level In flight: the FADEC decides between a windmilling start and a starter-assisted start; MASTER OFF interrupts 10 20 30 40 50 60 N2 % bowed rotor critical speed motoring: N2 held around 30 % up to 60 s normal start continues Motoring time depends on residual heat and vibration on every ground start and ground crank (LEAP-1A) time after the start command (illustrative)
Chapter 33 · Engine Start, Ignition, Reversers and Indications
18
e-books by eatpl.in · © 2026 · Do not copy or distribute
The LEAP brings a new idea: bowed rotor protection. After an engine is shut down, the hot core cools unevenly and the rotor can bend very slightly. Spinning it to high speed in that state could make the blades rub. So, depending on the thermal state of the engine, the FADEC first motors the engine with the starter, a pre-start dry cranking of up to sixty seconds, and it does this on every ground start and every ground crank. During this motoring it limits N2 to about thirty per cent, below the bowed rotor critical speed. The motoring time varies with the residual heat and the vibration level. In flight, the FADEC decides whether the engine is windmilling fast enough to start by itself or needs the starter, and you can interrupt the sequence with the master lever.
Manual start
When the automatic start fails Sequence: MODE IGN/START → MAN START ON (start valve opens) → MASTER ON (HP valve, both igniters) Start valve closes and ignition stops at 50 % N2 (CFM) or 63 % (LEAP) The FADEC only monitors passively : the crew watches the engine and interrupts if ECAM warns FADEC aborts a manual start only on the ground , for an EGT overlimit before 50 % N2 (LEAP also starter shaft shear, dual N2 sensor failure) In flight, the FADEC always commands a starter-assisted start 1 MODE → IGN/START ENG page, packs close 2 MAN START pb → ON start valve opens, N2 rises 3 MASTER → ON HP fuel valve opens, BOTH igniters 4 N2 50 % (CFM) / 63 % (LEAP) start valve closes, ignition off 5 MAN START off, MODE NORM after the start FADEC only monitors (passive); the crew watches N2, EGT, FF In flight: the FADEC cannot abort a manual start On the ground it aborts only for: EGT limit exceeded before 50 % N2 (LEAP also: starter shaft shear, dual N2 sensor failure)
Chapter 33 · Engine Start, Ignition, Reversers and Indications
19
e-books by eatpl.in · © 2026 · Do not copy or distribute
If an automatic start is not successful, you can try a manual start, in which the FADEC has limited control and you must watch the acceleration yourself. Turn the mode selector to IGN START and press the manual start button on: the start valve opens and N2 rises. When N2 is sufficient, set the master lever ON: the HP fuel valve opens and both igniters fire. The FADEC closes the start valve and stops the ignition at fifty per cent N2 on the CFM, sixty three on the LEAP. Throughout, the FADEC only monitors. It cannot abort a manual start in flight, and on the ground it aborts only if the start EGT limit is exceeded before fifty per cent N2, and on the LEAP also for a starter shaft shear or a dual N2 sensor failure. In flight, it always uses the starter.
Part 4 · Indications
The engine part of the E/WD 5 10 84. 6 AVAIL 735 5 10 84. 6 742 N1 % EGT °C N2 % FF KG/H 95. 1 2580 95. 2 2600 CLB 89.0 % 1 2 3 4 5 6 7 8 9 1 N1: needle and value (green) 2 N1 limit: amber mark (TO/GA N1) 3 Thrust lever position: blue circle 4 N1 red line 5 AVAIL (or REV) box 6 EGT with amber limit and red line 7 N2 (grey box during start or crank) 8 Fuel flow 9 Thrust rating mode and N1 limit The FADEC sends these values to the display; amber CHECK appears if a displayed value disagrees with the FADEC data.
Chapter 33 · Engine Start, Ignition, Reversers and Indications
20
e-books by eatpl.in · © 2026 · Do not copy or distribute
Now the indications, starting with the engine part of the engine and warning display. Here it is in a normal climb. At the top are the two N1 gauges with a green needle and a digital value. Around each dial you see the amber N1 limit mark, the blue circle showing where the thrust lever is, and the red line at the red limit. A box above the N1 value shows AVAIL after a start, or REV when the reverser is in use. Below are the E G T gauges, each with its own amber limit and red line, then N2 as a number, and fuel flow. In the top right corner is the thrust rating mode with its N1 limit, which we met in the last lesson. Let us look at each gauge in detail.
N1 indication
Reading the N1 gauge Green normal; amber above the N1 limit; red above the red limit (104 % CFM, 101 % LEAP)Amber mark: N1 limit , the maximum N1 with the levers at TO/GA Blue circle: thrust lever position With A/THR active: N1 command (target), transient arcs and the trend Red exceedance mark stays until the next ground start or maintenance; amber dashes = degraded accuracy 5 10 84. 6 A/THR active: command and transient arc 5 10 97. 0 Amber: above the N1 limit 5 10 105. 5 Red: above the red limit; red mark stays 5 10 84.– 84. Degraded accuracy: amber dashes
Chapter 33 · Engine Start, Ignition, Reversers and Indications
21
e-books by eatpl.in · © 2026 · Do not copy or distribute
The N1 needle and value are green in the normal range. They turn amber when N1 exceeds the N1 limit, and red above the red limit, which is one hundred and four per cent on the CFM and one hundred and one on the LEAP. The amber mark on the scale is the N1 limit, the maximum N1 with the levers at TO GA. The blue circle shows where the thrust lever is. When the autothrust is active, three more symbols appear: the N1 command, which is the autothrust target, the four green transient arcs filling the gap between actual N1 and the command, and the trend. If N1 has gone above the red limit, a red exceedance mark records the highest value reached, and it stays until the next ground start or a maintenance action. Amber dashes over the last digit mean the measurement is degraded.
EGT and N2
EGT, N2 and their limits EGT green normal, amber above the amber limit, red above the red line Amber limit line: 725 / 915 °C (CFM), 750 / 1 025 °C (LEAP): start on the ground / otherwise Amber limit not shown in TOGA or go-around mode, with reverse selected, or in alpha floor Red line: 950 °C (CFM), 1 060 °C (LEAP); red exceedance mark as for N1 N2 red limit 105 % (CFM), 116.5 % (LEAP) with a red cross 560 ground start: limit 725 930 amber: above 915 965 red: above 950 CFM56-5B EGT (examples) CFM56-5B LEAP-1A EGT scale 0–1 000 °C 0–1 200 °C Amber limit, ground start 725 °C 750 °C Amber limit, otherwise 915 °C 1 025 °C EGT red line 950 °C 1 060 °C N1 red limit 104 % 101 % N2 red limit (red cross) 105 % 116.5 %
Chapter 33 · Engine Start, Ignition, Reversers and Indications
22
e-books by eatpl.in · © 2026 · Do not copy or distribute
The E G T gauge works the same way. Green is normal, amber is above the amber limit and red is above the red line. The amber limit line changes with the situation. On the CFM it is seven hundred and twenty five degrees during a ground start and nine hundred and fifteen otherwise; on the LEAP, seven hundred and fifty and one thousand and twenty five. It is not shown in take-off or go-around mode, with the reversers selected, or in alpha floor, when you are expected to use all the thrust available. The red line is nine hundred and fifty on the CFM and one thousand and sixty on the LEAP, and a red exceedance mark records any overtemperature. N2 has a red limit of one hundred and five per cent on the CFM and one hundred and sixteen point five on the LEAP, shown with a red cross.
E/WD indications
N2 box, AVAIL, IDLE, REV and CHECK N2 in a grey box : start or crank in progress AVAIL : engine started and at or above idle; steady 10 s on the ground, pulses 1 min after a relight; goes when the lever leaves idleIDLE (green): both engines at idle in flight ; pulses 10 sREV : amber when unlocked (pulses 9 s in flight); green when fully deployed on the groundAmber CHECK under N1, N2, EGT or FF: displayed value disagrees with the FADEC data 22.4 start or crank in progress AVAIL ground: 10 s after a start IDLE both engines at idle, in flight REV reverser unlocked REV fully deployed (ground) CHECK displayed value ≠ FADEC data IDLE pulses 10 s · AVAIL pulses 1 min after an in-flight relight · REV pulses 9 s in flight
Chapter 33 · Engine Start, Ignition, Reversers and Indications
23
e-books by eatpl.in · © 2026 · Do not copy or distribute
A few more E/WD indications. During a start or a crank, the N2 value sits in a grey box. When the start is complete, AVAIL appears in the box above N1: on the ground it is steady for ten seconds after a successful start, and in flight it pulses for one minute after a successful relight. It disappears when you move the lever forward of idle. IDLE in green at the top centre means both engines are at idle in flight; it pulses for ten seconds, then stays steady, a useful cue during descent. REV in amber means a reverser is unlocked; in flight it pulses for nine seconds then stays steady, which should get your attention. REV in green means fully deployed on the ground. Finally, an amber CHECK under a parameter means the displayed value disagrees with the FADEC data.
ECAM ENGINE page
The ENGINE system page ENGINE F.USED KG 1530 1560 OIL QT PSI 15. 0 40 16. 0 45 °C 95 100 VIB N1 N2 0.8 1.1 0.9 1.2 IGN PSI A 34 NAC °C 185 190 1 2 3 4 5 6 7 8 9 1 Fuel used (resets at the next ground start) 2 Oil quantity, QT (amber advisory mark) 3 Oil pressure, PSI 4 Oil temperature, °C 5 N1 and N2 vibration 6 Igniter in use: A, B or AB 7 Start valve (in line = open) 8 Starter inlet pressure, PSI 9 Nacelle temperature (when high) The page appears by itself when MODE is set to IGN/START; nacelle temperature appears only when it is high.
Chapter 33 · Engine Start, Ignition, Reversers and Indications
24
e-books by eatpl.in · © 2026 · Do not copy or distribute
This is the ENGINE system page during the start of engine one. At the top, fuel used by each engine, which resets on the ground at the next engine start and counts in steps of ten kilograms. Then the oil: quantity in quarts on a small dial with an amber advisory mark, pressure in P S I, and temperature in degrees. Below are the N1 and N2 vibration levels. The lower part shows the start: which igniter is in use, A, B or both, the start valve symbol, in line when open and cross line when closed, and the starter inlet pressure. At the bottom, the nacelle temperature appears only when it goes above its advisory limit outside the start. A fuel or oil filter CLOG message can also appear under the fuel used or oil pressure.
ENGINE page values
Oil, vibration, start and nacelle Indication CFM56-5B LEAP-1A Oil quantity scale / advisory 0–22 QT; pulses green below the advisory (3 QT mark) 0–24.25 QT; pulses green below 1.35 QT Oil pressure 0–100 PSI; pulses above 90, or 13–16 PSI with N2 > 75 %; red 0–13 PSI 0–130 PSI; pulses outside the advisory limits (low limit with N2 > 75 %); red range Oil temperature pulses between advisory and caution for less than 15 min; amber after 15 min or above caution (older aircraft: 140–155 °C, amber above 155 °C) same logic; amber also under the minimum temperature for take-off N1 / N2 vibration pulses green when excessive amber when excessive Starter inlet pressure amber if abnormally high, or below 21 PSI with N2 > 10 % and valve not closed same Nacelle temperature pulses above the 240 °C advisory pulses above the advisory Fuel used multiples of 10 kg; amber dashes if fuel flow invalid in flight for over 1 min same
Chapter 33 · Engine Start, Ignition, Reversers and Indications
25
e-books by eatpl.in · © 2026 · Do not copy or distribute
Here are the numbers on the ENGINE page, which differ by engine type. Oil quantity on the CFM uses a scale up to twenty two quarts and pulses green below the advisory mark at three quarts; the LEAP scale goes to twenty four point two five and pulses below one point three five. Oil pressure on the CFM pulses above ninety P S I, or between thirteen and sixteen with N2 above seventy five per cent, and is red below thirteen. Oil temperature pulses between the advisory and caution thresholds for less than fifteen minutes, then turns amber. Vibration pulses green on the CFM and goes amber on the LEAP. The starter inlet pressure turns amber below twenty one P S I when N2 is above ten per cent and the valve is not closed. And the CFM nacelle temperature advisory is two hundred and forty degrees.
Memos and a known quirk
Engine memos and a spurious FUEL LEAK IGNITION (green): continuous ignition on, on any engineENG 1(2) COWL (amber, LEAP): fan cowl not closed, on the groundLEAP: ENG 1(2) FUEL LEAK may appear on an engine that has no leak Why: the FWC compares fuel flows; a misbehaving engine with lower flow can make the other engine look leaky Before shutting down, confirm : N1, FOB, fuel used, fuel flow, distribution, imbalance on both engines memo area of the E/WD IGNITION continuous ignition on ENG 1 COWL fan cowl not closed, on the ground (LEAP-1A) ENG 1(2) FUEL LEAK: may be spurious (LEAP-1A) The FWC compares the two engines' fuel flows. If one engine misbehaves and its fuel flow drops, with both levers in the same position the FWC may blame the OTHER engine (higher fuel flow). Before any shutdown, confirm the leak on both engines: N1, FOB, fuel used, fuel flow, fuel distribution and imbalance.
Chapter 33 · Engine Start, Ignition, Reversers and Indications
26
e-books by eatpl.in · © 2026 · Do not copy or distribute
Two engine memos. IGNITION in green means continuous ignition is on, on at least one engine. On the LEAP aircraft, ENG one or ENG two COWL appears in amber on the ground when that engine's fan cowl is not closed, an important check before taxi. There is also a known temporary quirk on the LEAP aircraft: a spurious ENG FUEL LEAK alert. One trigger for that alert is a comparison of the two engines' fuel flows. If one engine misbehaves and its fuel flow drops, and both levers are in the same position, the warning computer may decide that the other engine, the one with the higher flow, is leaking. Since the procedure asks you to shut down the leaking engine, always confirm first: compare N1, fuel on board, fuel used, fuel flow, distribution and imbalance on both engines.
Summary
Engine operation in one page Reversers Green ENG 1, yellow ENG 2. FADEC + gear compressed + SEC (+ EIU on LEAP). Reverse idle until fully deployed; idle protection.
TCMA (LEAP) Ground, take-off, approach. Flight: fuel cutback. Ground at idle/reverse: shutdown by the HPSOV. FAULT light.
Ignition A and B, either channel fires both. Auto start: one igniter, alternated; manual and in-flight: both.
Auto start MODE IGN/START: ENG page, packs close. MASTER ON. CFM: 16 % ign, 22 % fuel, 50 % valve shut. LEAP: 15/20/55/63 %.
Manual and crank MAN START ON + MASTER ON; FADEC passive. CRANK + MAN START ON: dry crank (MASTER OFF), wet crank (MASTER ON).
Indications N1 red 104/101 %, EGT red 950/1 060 °C, N2 red 105/116.5 %. AVAIL, IDLE, REV, CHECK. IGNITION memo.
Chapter 33 · Engine Start, Ignition, Reversers and Indications
27
e-books by eatpl.in · © 2026 · Do not copy or distribute
To finish, the essentials. The reversers are powered by green on engine one and yellow on engine two, and need the FADEC, both main gears compressed and a SEC, plus the interface unit on the LEAP, with thrust held at reverse idle until fully deployed. TCMA protects the LEAP on the ground, in take-off and in approach. Each engine has igniters A and B, either FADEC channel can fire both, and the automatic start uses one at a time. For the automatic start, remember the CFM numbers: sixteen per cent ignition, twenty two fuel, fifty valve closed, and the LEAP numbers alongside. Manual start means the FADEC only watches, and CRANK with the manual start button gives you a dry or a wet crank. And learn your red limits for N1, E G T and N2.