A320 Aircraft Systems · Chapter 14
Fire Protection How the A320 detects fire and smoke in the engines, APU, cargo holds, lavatories and avionics bay, how it warns you, and what each pushbutton on the FIRE and CARGO SMOKE panels really does.
F I R E F I R E ENG 1 FIRE PUSH AGENT 1 SQUIB DISCH AGENT 2 SQUIB DISCH TEST ENG 2 FIRE PUSH AGENT 1 SQUIB DISCH AGENT 2 SQUIB DISCH TEST APU FIRE PUSH AGENT SQUIB DISCH TEST ENG 1 FIRE detect · alert · isolate · extinguish © 2026 eatpl.in. For the personal study of eatpl.in students only. Do not copy or distribute.
e-books by eatpl.in · © 2026 · Do not copy or distribute
Welcome to fire protection, chapter twenty-six. Of all the warnings on the A320, the fire warning is the one that makes everybody sit up: a continuous chime, red lights and a red ECAM title. In this lesson we take the system apart calmly. We will see how two detection loops and a fire detection unit decide that there really is a fire, what the FIRE panel pushbuttons do the moment you push them, how the APU looks after itself on the ground, and how smoke is detected in the avionics bay, the lavatories and the cargo holds. By the end, every light on the FIRE and CARGO SMOKE panels should make sense to you.
Lesson roadmap
Fire protection in four parts ATA chapter 26 . Detection is automatic ; extinguishing is mostly crew-commanded , with one automatic exception: the APU on the ground .
1 · Detection What is protected. Engine and APU loops A and B , the FDU and its logic, flame effect and loop faults.
2 · Engine fire Fire bottles and squibs, the FIRE panel , the ENG FIRE pb , AGENT pbs, the ENG MASTER light and the TEST .
3 · APU fire The APU FIRE pb , automatic shutdown and discharge on the ground, the external panel and the APU tests.
4 · Smoke Avionics , lavatory and cargo smoke detection, cargo extinguishing variants and the CARGO SMOKE panel.
Chapter 14 · Fire Protection
2
e-books by eatpl.in · © 2026 · Do not copy or distribute
Here is our plan for chapter twenty-six. In part one we look at what is protected and how the engines and the APU detect a fire, using two loops and a fire detection unit, with a logic that tolerates a failed loop. In part two we stay with the engine fire: the bottles and their squibs, the FIRE panel, what the ENG FIRE pushbutton does when you push it, and how to read the SQUIB, DISCH and FIRE lights, including the test. Part three is the APU, which has one special trick: on the ground it shuts itself down and fires its own bottle. Part four is smoke: in the avionics bay, the lavatories and the cargo holds, with the cargo extinguishing systems and their timings. Detection is always automatic; extinguishing is mostly your decision.
Part 1 · Overview
What is protected, and how ENG FWD hold AFT hold avionics LAV LAV APU Engines fire + overheat: 2 loops, FDU · 2 bottles each APU 2 loops, FDU · 1 bottle (automatic on ground) Cargo holds smoke detectors · fire bottle(s) Avionics bay one smoke detector in the extract duct Lavatories smoke detector · wastebin extinguisher Plus portable fire extinguishers in the cockpit and the cabin. Fire + overheat detection : engines, APU. Smoke detection : cargo, lavatories, avionics bay. Extinguishing : engines, APU, cargo, lavatory wastebins.
Chapter 14 · Fire Protection
3
e-books by eatpl.in · © 2026 · Do not copy or distribute
Let us start with a map of the aircraft. The two engines have fire and overheat detection, and each has two fire bottles. The APU, in the tail cone, has the same kind of detection and one bottle, which on the ground can fire by itself. The forward and aft cargo holds have smoke detection and an extinguishing system. The avionics bay has one smoke detector, in the extract duct of the avionics ventilation. The lavatories have smoke detectors too, and each lavatory wastebin has its own automatic extinguisher. Notice the pattern: fire and overheat detection where there is fuel and hot metal, smoke detection where people and equipment are. And in the cockpit and the cabin there are portable extinguishers for anything else.
Part 1 · Overview
Detection and extinguishing, area by area Area Detection Extinguishing Crew control Engines (each) fire + overheat: loops A and B, FDU 2 bottles, squibs with dual supply FIRE panel: ENG FIRE pb, AGENT 1, AGENT 2 APU fire + overheat: loops A and B, FDU 1 bottle, 2 squibs; automatic on ground FIRE panel: APU FIRE pb, AGENT Cargo holds smoke detectors in pairs (dual loop) 1 or 2 bottles, nozzles in both holds CARGO SMOKE panel Lavatories smoke detector in the extract duct automatic wastebin extinguisher warning only Avionics bay smoke detector in the extract duct none fixed smoke procedure (ventilation, electrics) Cockpit and cabin crew portable extinguishers crew
Fire and overheat detection is automatic everywhere; only the APU bottle fires automatically , and only on the ground.
Chapter 14 · Fire Protection
4
e-books by eatpl.in · © 2026 · Do not copy or distribute
This table is worth a careful look, because examiners love to mix up the rows. Engines and APU have fire and overheat detection through two loops and a fire detection unit. The engines have two bottles each; the APU has one bottle with two squibs. The cargo holds use smoke detectors working in pairs and have one or two bottles, depending on the aircraft. The lavatories have a smoke detector in the extract duct and an automatic extinguisher in each wastebin. The avionics bay has a smoke detector but no fixed extinguisher. And in the right-hand column you can see where you act: the FIRE panel for engines and APU, the CARGO SMOKE panel for the holds. Only one bottle on the aircraft fires without you: the APU bottle, on the ground.
Part 1 · Engine and APU detection
Two loops and a fire detection unit Engines and APU: two identical loops, A and B , mounted in parallel , and an FDU Engine sensing elements: pylon nacelle , engine core , fan section (three or four, as installed) APU: one sensing element in the APU compartment Heat on an element sends a signal to the FDU Normally both loops must see the heat before the warning Engine fire detection core fan pylon nacelle fan section engine core FDU AND Loop A Loop B identical, in parallel; 3 or 4 sensing elements per engine, as installed APU: one sensing element in its compartment
Chapter 14 · Fire Protection
5
e-books by eatpl.in · © 2026 · Do not copy or distribute
Each engine, and the APU, has its own fire and overheat detection system. It is built from two identical detection loops, called A and B, mounted in parallel, and a fire detection unit, the F D U. On the engine, the loops run past sensing elements in the pylon nacelle, around the engine core and in the fan section, three or four of them depending on the installation. The APU loops have one sensing element in the APU compartment. When an element gets hot, it signals the fire detection unit. Why two loops? Because a single wire could give a false fire warning if it were damaged, and a false engine fire warning can lead to an engine being shut down for nothing. So in normal operation, both loops must report the heat before the warning triggers.
Part 1 · FDU logic
When does the fire warning come on? Loop A FIRE + Loop B FIRE both loops agree One loop FIRE + other loop FAILED the healthy loop is enough Both loops break within 5 s “flame effect” FIRE TEST pb pressed crew test OR FIRE WARNING Continuous repetitive chime MASTER WARN lights flash ECAM: ENG 1 FIRE (red) ENG FIRE pb lights red ENG MASTER panel: FIRE red One loop FAILED (break or no power) the other loop still protects LOOP fault caution AND logic while both loops work, OR logic when one fails. A loop fault alone gives only a caution .
Chapter 14 · Fire Protection
6
e-books by eatpl.in · © 2026 · Do not copy or distribute
The fire detection unit triggers the fire warning in four cases. One: both loops send a fire signal. Two: one loop sends a fire signal and the other loop has failed, so the unit trusts the healthy loop. Three: both loops break within five seconds of each other. This is called the flame effect: a real fire can burn through both wires almost together, and the unit treats that as a fire, not as two faults. Four: a test from the FIRE panel. The result is the full warning: continuous repetitive chime, flashing MASTER WARN, a red ECAM title, the red light in the ENG FIRE pushbutton and the red FIRE light on the ENG MASTER panel. And if just one loop fails, by a break or a loss of power, you get only a loop fault caution; the other loop still protects the engine.
Part 1 · Worked cases
Apply the logic: what do you get? Loop A Loop B Result Why fire signal fire signal FIRE warning both loops agree (AND) fire signal failed (earlier) FIRE warning one loop fire + other failed (OR) failed normal LOOP fault caution the healthy loop still protects breaks breaks 3 s later FIRE warning both breaks within 5 s: flame effect breaks breaks 2 min later loop fault cautions not within 5 s: treated as two faults normal normal, TEST pressed FIRE warning (test)the test simulates a fire
The FDU processes all warnings and cautions from the sensing elements.
Chapter 14 · Fire Protection
7
e-books by eatpl.in · © 2026 · Do not copy or distribute
Let us practise with six cases. If both loops signal fire, you get the fire warning. If loop A signals fire while loop B has already failed, you still get the warning, because the logic switches to OR when one loop is inoperative. If loop A fails and loop B is normal, there is no fire: you get a loop fault caution, and loop B carries on protecting the engine. Now the interesting pair. Both loops break, the second three seconds after the first: that is inside the five-second window, so the unit calls it a flame effect and gives the fire warning. But if the second break comes two minutes later, the unit sees two separate faults and gives loop fault cautions, not a fire warning. Finally, pressing the TEST pushbutton simulates a fire, so you get the warning on purpose.
Part 2 · Extinguishing
Bottles and squibs Each engine : two fire extinguisher bottles Each bottle is fired by an electrically-operated squib Each squib has a dual electric supply APU : one bottle with two squibsCrew fires them from the FIRE panel ; the APU bottle also fires automatically on the ground Engine: two bottles bottle 1 squib bottle 2 squib engine nacelle each squib: dual electric supply AGENT 1 fires bottle 1 · AGENT 2 fires bottle 2 APU: one bottle, fired by either of two squibs
Chapter 14 · Fire Protection
8
e-books by eatpl.in · © 2026 · Do not copy or distribute
Now the extinguishing side. Each engine has two fire extinguisher bottles. A bottle is opened by a squib, a small electrically fired cartridge that ruptures the outlet so the agent rushes down the pipe into the nacelle. Each squib has a dual electric supply, so one electrical failure cannot leave you unable to fire it. Watch the model: when the squib fires, bottle one discharges into the nacelle in a few seconds, and if the fire is extinguished, the warning goes away. The second bottle is kept in reserve, fired by its own AGENT pushbutton. The APU is simpler: one bottle, but with two squibs. The crew normally fires all of these from the FIRE panel, and the APU bottle can also fire automatically when the aircraft is on the ground.
Part 2 · Overhead panel
The FIRE panel F I R E F I R E ENG 1 FIRE PUSH AGENT 1 SQUIB DISCH AGENT 2 SQUIB DISCH TEST ENG 2 FIRE PUSH AGENT 1 SQUIB DISCH AGENT 2 SQUIB DISCH TEST APU FIRE PUSH AGENT SQUIB DISCH TEST 1 2 3 4 5 1 ENG 1(2) FIRE pb guarded; red with the fire warning 2 AGENT 1(2) pb SQUIB white · DISCH amber 3 APU FIRE pb guarded; red with an APU fire 4 APU AGENT pb one bottle 5 TEST pb ENG 1, APU and ENG 2 Normal flight: all lights out . The FIRE pbs are guarded and normally in .
Chapter 14 · Fire Protection
9
e-books by eatpl.in · © 2026 · Do not copy or distribute
Here is the FIRE panel on the overhead, laid out exactly like the aircraft from left to right: engine one, the APU, engine two. For each engine there is a large guarded pushbutton marked FIRE and PUSH. Either side of it is an AGENT pushbutton, AGENT 1 on the left and AGENT 2 on the right, each with a SQUIB legend and a DISCH legend. Each engine also has a small round TEST pushbutton. In the middle the APU has the same idea with one AGENT pushbutton and its own TEST. In normal flight everything on this panel is dark, the guards are closed and the FIRE pushbuttons are pushed in. Remember the layout: it helps you put your hand on the correct engine without hesitation when the warning comes.
Part 2 · ENG FIRE pb
What the ENG FIRE pushbutton does Normally in and guarded ; pushing it releases it (it pops out) Silences the aural warning and arms the squibs Closes the LP fuel valve , the hydraulic fire shut-off valve , the engine bleed valve and the pack flow control valve Cuts the FADEC power supply and deactivates the IDG Its red light follows the fire warning , whatever its position FIRE PUSH push: the pb is released (it pops out) Aural fire warning silenced Fire extinguisher squibs armed Low-pressure fuel valve closes Hydraulic fire shut-off valve closes Engine bleed valve closes Pack flow control valve closes FADEC power supply cut IDG deactivated Colour key fuel hydraulics air (bleed, pack) electrics, FADEC fire agent
Chapter 14 · Fire Protection
10
e-books by eatpl.in · © 2026 · Do not copy or distribute
When you lift the guard and push the ENG FIRE pushbutton, it is released, it pops out, and it sends one electrical signal that does eight things for that engine. It silences the aural fire warning and arms the extinguisher squibs. It isolates the engine from everything that could feed or spread a fire: the low-pressure fuel valve closes, the hydraulic fire shut-off valve closes, the engine bleed valve closes and the pack flow control valve on that side closes. Finally it cuts the FADEC power supply and deactivates the I D G, the engine-driven generator. Notice what it does not do: it does not discharge any agent. That is a separate, deliberate push. And the red light in the pushbutton simply follows the fire warning, whether the pushbutton is in or out.
Part 2 · AGENT pushbuttons
SQUIB and DISCH Both AGENT pbs of an engine become active when its ENG FIRE pb is released SQUIB white: armed; it shows you which pb to pressA brief push discharges that agent DISCH amber: that bottle has lost pressure The APU AGENT pb works the same way The AGENT pushbutton SQUIB DISCH Normal dark: not armed SQUIB DISCH ENG FIRE pb released SQUIB white: armed, push me SQUIB DISCH Bottle discharged DISCH amber: lost pressure A brief push discharges that bottle.
Chapter 14 · Fire Protection
11
e-books by eatpl.in · © 2026 · Do not copy or distribute
The AGENT pushbuttons are dead until you release the ENG FIRE pushbutton for that engine. At that moment both of its AGENT pushbuttons become active and their SQUIB legends come on white. Think of SQUIB as a finger pointing: these are the buttons that are now armed, on the side where you pushed the FIRE pushbutton. A brief push on an AGENT pushbutton fires its squib and discharges that bottle. When the bottle has lost its pressure, the DISCH legend comes on amber, confirming that the agent has gone. So the colours tell a story: white means ready, amber means done. The APU AGENT pushbutton follows exactly the same rules, after you release the APU FIRE pushbutton.
Part 2 · Worked sequence
An engine 1 fire, light by light 1 · Normal ENG 1 FIRE PUSH AGENT 1 SQUIB DISCH AGENT 2 SQUIB DISCH ENG MASTER 1 FIRE 2 · ENG 1 fire warning ENG 1 FIRE PUSH AGENT 1 SQUIB DISCH AGENT 2 SQUIB DISCH ENG MASTER 1 FIRE 3 · ENG 1 FIRE pb pushed ENG 1 FIRE PUSH AGENT 1 SQUIB DISCH AGENT 2 SQUIB DISCH ENG MASTER 1 FIRE 4 · AGENT 1 pushed ENG 1 FIRE PUSH AGENT 1 SQUIB DISCH AGENT 2 SQUIB DISCH ENG MASTER 1 FIRE all dark FIRE pb red · ENG MASTER FIRE red SQUIB lights white DISCH 1 amber (bottle 1 empty) The red FIRE lights stay on as long as the fire warning is active, whatever the pushbutton position. The order is always the same: warning → FIRE pb (isolate, arm) → AGENT (discharge) → DISCH confirms.
Chapter 14 · Fire Protection
12
e-books by eatpl.in · © 2026 · Do not copy or distribute
Let us walk through an engine one fire and watch the lights. Step one, everything is dark. Step two, the fire detection unit declares a fire: the ENG 1 FIRE pushbutton lights red on the overhead, and the FIRE light under master switch one lights red on the pedestal, showing you which engine is affected. Step three, after the procedure brings you to it, you push the ENG 1 FIRE pushbutton: it pops out, the engine is isolated, and both SQUIB lights on engine one come on white. Step four, you push AGENT 1: bottle one discharges and, once it has lost its pressure, DISCH 1 comes on amber. If the fire warning goes out, the red lights go out with it. If it stays, AGENT 2 is ready, still showing SQUIB. Always follow the ECAM and your procedures for the exact actions and timing.
Part 2 · Pedestal
The FIRE light on the ENG MASTER panel ENG 1(2) FIRE light: red with that engine’s fire warningIt identifies the engine to be shut down It is right next to the ENG MASTER lever you will use Overhead and pedestal agree: two red cues for one engine ENG MASTER 1 ON OFF MASTER 2 ON OFF CRANK NORM IGN START MODE FIRE FAULT FIRE FAULT 1 2 ENG 1(2) FIRE light: red comes on with that engine’s fire warning shows which engine to shut down (the light is on the pedestal, next to the master lever)
Chapter 14 · Fire Protection
13
e-books by eatpl.in · © 2026 · Do not copy or distribute
On the pedestal, below each engine master lever, there is a FIRE light. It comes on red when that engine fire warning is triggered. Its job is very practical: it identifies the engine to be shut down, right next to the master lever that you will move. So in a fire you have two red cues that must agree: the ENG FIRE pushbutton on the overhead and the FIRE light on the pedestal. Good crews confirm both before touching anything, because shutting down the wrong engine turns one problem into two. The light is driven by the same fire warning as the overhead pushbutton, so the two always come on together.
Part 2 · FIRE TEST
Testing the engine fire system ENG 1(2) TEST pb: tests detection and extinguishing for that engine Gives the full warning: CRC , MASTER WARN , ECAM ENG FIRE FIRE pb red , SQUIB white (if supplies available), DISCH amber ENG MASTER panel FIRE light red Trap: that light stays off with a loop A fault on ENG 1 or loop B fault on ENG 2 ENG 1 FIRE TEST pressed ENG 1 FIRE PUSH AGENT 1 SQUIB DISCH AGENT 2 SQUIB DISCH TEST ENG MASTER 1 FIRE (see the note below) CRC sounds MASTER WARN ENG 1 FIRE FIRE pb red · SQUIB white (if discharge supplies available) DISCH amber on both AGENT pbs Note: the ENG MASTER FIRE light does not come on during the test with a LOOP A fault on engine 1, or a LOOP B fault on engine 2. The test checks detection and extinguishing circuits.
Chapter 14 · Fire Protection
14
e-books by eatpl.in · © 2026 · Do not copy or distribute
Each engine has a TEST pushbutton on the FIRE panel. Pressing it tests the detection and extinguishing circuits for that engine, and you should see the complete picture of a fire. A continuous repetitive chime sounds, the MASTER WARN lights flash, and the ECAM shows the engine fire warning. On the FIRE panel, the ENG FIRE pushbutton lights red, the SQUIB lights come on white if their discharge supplies are available, and the DISCH lights come on amber. On the pedestal, the FIRE light lights red. There is one detail worth remembering: during the test that pedestal FIRE light does not come on if engine one has a loop A fault, or engine two has a loop B fault. So a missing light during the test can point you to a loop problem.
Part 3 · APU fire
The APU FIRE pushbutton Same idea: in and guarded ; push to release Shuts down the APU , silences the aural warning, arms the squib Closes the LP fuel valve and shuts off the APU fuel pump Closes the APU bleed valve and the X BLEED valve Deactivates the APU generator ; red light follows the APU fire warning FIRE PUSH APU FIRE pb pushed APU shuts down Aural warning silenced APU squib armed Low-pressure fuel valve closes APU fuel pump off APU bleed valve closes X BLEED valve closes APU generator deactivated Compare ENG FIRE pb: same idea, different systems. The APU has no hydraulic valve and no IDG; it closes the X BLEED valve too.
Chapter 14 · Fire Protection
15
e-books by eatpl.in · © 2026 · Do not copy or distribute
The APU FIRE pushbutton works like the engine ones, adapted to the APU. It is guarded and normally in. When you push it, it is released and it shuts the APU down, silences the aural warning and arms the squib on the APU bottle. It stops fuel twice over: the low-pressure fuel valve closes and the APU fuel pump is shut off. It isolates the air side by closing the APU bleed valve and also the crossbleed valve, and it deactivates the APU generator. Compare it with the engine pushbutton: there is no hydraulic valve and no I D G, but there is the crossbleed valve, because APU air reaches the engine side through the crossbleed duct. As before, the red light follows the APU fire warning, whatever the pushbutton position.
Part 3 · APU fire on the ground
The APU looks after itself on the ground APU 0 1 2 3 4 5 6 s APU fire detected on the ground APU shuts down automatically · APU FIRE warning External panel: APU FIRE light + horn to alert the ground crew Bottle discharges automatically 3 s after the fire warning Ground crew can stop it too APU SHUT OFF pb (external panel): · closes the APU LP fuel shut-off valve · ECB runs the normal auto shutdown, with no cool-down cycle · silences the external horn The external APU FIRE light goes out when the fire has been extinguished. On the ground: automatic shutdown , external APU FIRE light + horn , and the bottle fires 3 s after the warning.
Chapter 14 · Fire Protection
16
e-books by eatpl.in · © 2026 · Do not copy or distribute
The APU is often running on the ground with nobody in the cockpit, so it has an automatic mode. When an APU fire is detected on the ground, the APU shuts down automatically. At the same time, a red APU FIRE light comes on and an external warning horn sounds on the external power panel, to alert the ground crew. Then, three seconds after the fire warning appears, the APU bottle discharges automatically. When the fire has been extinguished, the external light goes out. The ground crew can also act: the APU SHUT OFF pushbutton on the same panel closes the APU low-pressure fuel valve and tells the APU controller to run the normal shutdown sequence, but without the cool-down cycle. It also silences the horn. In flight, there is no automatic discharge: the crew uses the FIRE panel.
Part 3 · Ground panels
External and maintenance panels External power panel: red APU FIRE light + horn APU SHUT OFF pb: emergency shutdown by the ground crew , no cool-down Maintenance panel APU AUTO EXTING : TEST and RESET TEST checks fire warning , auto extinguishing , shutdown ; needs APU MASTER ON OK light = circuits good; a running APU shuts down External power panel (APU part) APU FIRE APU SHUT OFF PUSH APU FIRE light: red + external horn goes out when the fire is extinguished APU SHUT OFF pb ground crew shutdown Maintenance panel: APU AUTO EXTING TEST OK ON RESET TEST: fire warning, auto extinguishing and shutdown circuits (APU MASTER sw ON) OK = all circuits good RESET: resets the test
Chapter 14 · Fire Protection
17
e-books by eatpl.in · © 2026 · Do not copy or distribute
Two small panels complete the APU story. On the external power panel, which the ground crew uses, you have the red APU FIRE light, which comes on with the external horn, and the APU SHUT OFF pushbutton for an emergency shutdown from outside. Remember that this shutdown skips the cool-down cycle. Then there is a maintenance panel labelled APU AUTO EXTING. Its TEST pushbutton tests three circuits: the fire warning, the automatic extinguishing and the shutdown. For the test the APU MASTER switch must be ON, and if everything is working the OK light comes on. Be careful: if the APU was running, the test shuts it down. The RESET pushbutton then resets the test circuit. These are mainly maintenance items, but they are favourite interview questions.
Part 3 · APU FIRE TEST
Testing the APU fire system APU TEST pb: CRC , MASTER WARN , ECAM APU FIRE APU FIRE pb red , SQUIB white (if supplies), DISCH amber On the ground, a test longer than 3 s may shut the APU down On batteries only : SQUIB and DISCH come on without ECAM warnings … and the red APU FIRE pb is only partly lit APU FIRE TEST pressed APU FIRE PUSH AGENT SQUIB DISCH TEST CRC MASTER WARN APU FIRE APU FIRE pb red · SQUIB white (if supplies available) · DISCH amber On the ground, holding the test for more than 3 s may shut the APU down automatically. On batteries only (ground): SQUIB and DISCH come on without ECAM warnings, and the red APU FIRE pb is only partly lit (one set of bulbs has no power).
Chapter 14 · Fire Protection
18
e-books by eatpl.in · © 2026 · Do not copy or distribute
The APU TEST pushbutton gives the same picture as the engine test: a continuous repetitive chime, flashing MASTER WARN, the APU FIRE warning on the ECAM, the APU FIRE pushbutton lit red, the SQUIB light white if supplies are available, and the DISCH light amber. There are two notes that catch people out. First, on the ground, if you hold the test for more than three seconds, the APU may shut down automatically, because the system believes there is a fire on the ground. So keep it short with the APU running. Second, if you test on the ground with only the batteries powering the aircraft, the SQUIB and DISCH lights come on but there are no ECAM warnings, and the red APU FIRE pushbutton light is only partly lit, because one set of its bulbs has no power.
Part 4 · Avionics bay
Avionics smoke detection One smoke detector in the avionics ventilation extract duct Smoke for more than 5 s → Single chime , MASTER CAUT , ECAM AVIONICS SMOKE GEN 1 LINE pb: amber SMOKE (EMER ELEC PWR panel)BLOWER and EXTRACT : amber FAULT (VENTILATION panel)extract duct S one smoke detector smoke for more than 5 s → single chime MASTER CAUT AVIONICS SMOKE EMER ELEC PWR panel GEN 1 LINE SMOKE OFF VENTILATION panel BLOWER FAULT OVRD EXTRACT FAULT OVRD The detection is in the avionics ventilation extract duct. There is no fixed extinguisher in the avionics bay.
Chapter 14 · Fire Protection
19
e-books by eatpl.in · © 2026 · Do not copy or distribute
The avionics bay is protected by one smoke detector, placed in the air extraction duct of the avionics ventilation, where all the air from the equipment racks flows past it. If it senses smoke for more than five seconds, you get a caution, not a warning: a single chime, flashing MASTER CAUT lights and the ECAM AVIONICS SMOKE alert. Three pushbuttons on the overhead also light up to guide your hands. On the EMER ELEC PWR panel, the GEN 1 LINE pushbutton shows an amber SMOKE light. On the VENTILATION panel, the BLOWER and EXTRACT pushbuttons show amber FAULT lights. These lights draw your eye straight to the pushbuttons that control the avionics ventilation and the generator one line. There is no fixed extinguisher in the avionics bay.
Part 4 · Lavatories
Lavatory smoke detection and wastebins One smoke detector in each lavatory extract duct Signal to a two-channel SDCU , or the CIDS with its smoke detection function (SDF ) Passed to the FWC : warnings in the cockpit and the cabin Each wastebin has an automatic fire extinguishing system lavatory waste bin wastebin: automatic fire extinguisher S smoke detector in the extract duct SDCU (2 channels) or CIDS with SDF FWC cockpit warning cabin warning Same detector principle as the avionics bay: smoke in the extracted air.
Chapter 14 · Fire Protection
20
e-books by eatpl.in · © 2026 · Do not copy or distribute
Each lavatory has one smoke detector, again in the air extraction duct, so it samples the air leaving the lavatory. Its signal goes to a smoke detection control unit with two channels, or, on aircraft with the newer cabin system, to the C I D S with its smoke detection function. From there it goes to the flight warning computer, which raises the warning in the cockpit and alerts the cabin crew in the cabin. The wastebin, where paper towels and the occasional cigarette end can start a fire, has its own automatic extinguishing system, so it needs no action from the flight deck. So the lavatory has both: early warning by smoke detection, and automatic protection where a fire is most likely to start.
Part 4 · Cargo holds
Cargo smoke detection FWD hold AFT hold Detectors sit in the ceiling panel cavities, in pairs: one on loop A (orange), one on loop B (yellow). Depending on the aircraft: 2 FWD + 4 AFT detectors, or 4 FWD + 6 AFT. SDCU (two identical channels) or CIDS-SDF → ECAM and the CARGO SMOKE panel. A smoke warning closes the cargo ventilation isolation valves and stops the extraction fan (where fitted). Detectors in the ceiling panel cavities , in pairs on two loops : 2 FWD + 4 AFT, or 4 FWD + 6 AFT, depending on the aircraft.
Chapter 14 · Fire Protection
21
e-books by eatpl.in · © 2026 · Do not copy or distribute
Now the cargo holds. Smoke detectors sit in the ceiling panel cavities of the forward and aft holds. Each cavity has two detectors, one connected to each of two detection loops, the same dual loop principle we met on the engines. The number depends on the aircraft: on some, two detectors forward and four aft; on others, four forward and six aft. The detectors feed a smoke detection control unit with two identical channels, or the C I D S smoke detection function, and that sends the alert to the ECAM and to the CARGO SMOKE panel. Because a hold is closed and cannot be reached in flight, this detection is your only window into it, which is why it is duplicated.
Part 4 · Cargo smoke logic
When does CARGO SMOKE come on? Per cavity: both detectors see smoke, or one sees smoke and the other is inoperative Red SMOKE light (FWD or AFT) + ECAM warning The cargo ventilation isolation valves close automatically The extraction fan stops (where fitted) Same AND / OR idea as the engine loops One cavity, two detectors detector, loop A SMOKE / OK / failed detector, loop B SMOKE / OK / failed AND both detect smoke, or one detects and the other is inoperative CARGO SMOKE red SMOKE light, FWD or AFT ECAM warning cargo isolation valves close extraction fan stops Ventilation is stopped so it does not feed or spread the fire.
Chapter 14 · Fire Protection
22
e-books by eatpl.in · © 2026 · Do not copy or distribute
The cargo smoke logic works cavity by cavity, and it should feel familiar. The warning comes on when both detectors in a cavity detect smoke, or when one detects smoke and the other is inoperative. That is the same and-or principle as the engine loops: protection against false alarms, without losing protection when one detector fails. When the warning triggers, the red SMOKE light comes on for the affected hold, the ECAM warning appears, and two things happen automatically: the cargo ventilation isolation valves close and the extraction fan stops, on aircraft fitted with cargo ventilation. Why? Ventilating a hold that is on fire would feed it fresh air and could spread smoke, and it would also blow the extinguishing agent away.
Part 4 · Cargo extinguishing
Two bottles: knock-down, then keep it down Two-bottle cargo systems 0 30 60 90 120 150 180 210 minutes after AGENT 1 5 nozzles each (2 FWD, 3 AFT) bottle 2 metered ≈ 60 min 150 min bottle 1 ≈ 60 s 2 heads, 3 nozzles (1 FWD, 2 AFT) bottle 2 metered ≈ 90 min 205 min bottle 1 ≈ 60 s DISCH AGENT 2 light: select AGENT 2 Worked example (first system): AFT SMOKE at 10:00, AGENT 1 at 10:01. Bottle 1 is empty by about 10:02 (DISCH 1 amber). At 11:01 DISCH AGENT 2 comes on: select AGENT 2. Bottle 2 meters out until about 12:01; agent concentration holds to about 12:31. Bottle 1 knocks the fire down in about 60 s; bottle 2 is metered to keep the concentration up. DISCH AGENT 2 comes on 60 min after AGENT 1.
Chapter 14 · Fire Protection
23
e-books by eatpl.in · © 2026 · Do not copy or distribute
On aircraft with two cargo bottles, the system works in two stages. When the SMOKE light comes on, you select the DISCH switch for that hold to AGENT 1. Bottle one empties in about sixty seconds: a big dose to knock the fire down. Sixty minutes after AGENT 1, the amber DISCH AGENT 2 light comes on, asking you to select AGENT 2. Bottle two is then released slowly through a flow metering system, to keep enough agent in the hold. Depending on the version, bottle two is metered over about sixty or about ninety minutes, and the total protection lasts about one hundred and fifty or two hundred and five minutes. In the worked example, smoke at ten o’clock gives agent cover until about half past twelve.
Part 4 · Cargo extinguishing
Know your aircraft: cargo variants Version Bottles and nozzles Crew control Agent cover Two bottles, 5 nozzles each 2 nozzles FWD, 3 nozzles AFT per bottle DISCH sw: AGENT 1, then AGENT 2 when DISCH AGENT 2 lights bottle 2 over ≈ 60 min · 150 min Two bottles, 2 discharge heads 1 nozzle FWD, 2 nozzles AFT DISCH sw: AGENT 1, then AGENT 2 bottle 2 over ≈ 90 min · 205 min One bottle, 2 discharge heads 1 nozzle FWD, 2 nozzles AFT FWD or AFT DISCH pb 135 min (one version) All versions one squib / head per hold DISCH amber when the bottle is empty within 60 s of the push
The bottles are shared by the two holds: the switch or pushbutton you use decides which hold gets the agent.
Chapter 14 · Fire Protection
24
e-books by eatpl.in · © 2026 · Do not copy or distribute
The cargo system is customer-specific, so learn the version on your aircraft. In one version, two bottles each feed five nozzles, two in the forward hold and three in the aft; you use the DISCH switch, AGENT 1 first and AGENT 2 when its light comes on, with about one hundred and fifty minutes of cover. In another, two bottles with two discharge heads feed three nozzles, one forward and two aft, with bottle two metered over about ninety minutes and about two hundred and five minutes of cover. In the simplest version, one bottle with two discharge heads is fired with a FWD or AFT DISCH pushbutton; one version of it quotes one hundred and thirty-five minutes. In every version the bottle is shared by both holds, and the amber DISCH light confirms the bottle is empty.
Part 4 · Cockpit
The CARGO SMOKE panel Two-bottle aircraft (DISCH sw: AGENT 1 / AGENT 2) CARGO SMOKE FWD SMOKE AFT SMOKE TEST DISCH AGENT 2 DISCH 1 DISCH 2 AGENT 1 AGENT 2 AGENT 1 AGENT 2 DISCH sw DISCH sw One-bottle aircraft (FWD and AFT DISCH pb) CARGO SMOKE FWD SMOKE DISCH AFT SMOKE DISCH TEST DISCH PUSH DISCH PUSH Both shown after an AFT smoke warning and a discharge. TEST pb: hold at least 3 s. SMOKE red · DISCH amber within 60 s of the discharge · DISCH AGENT 2 amber 60 min after AGENT 1 · TEST : hold ≥ 3 s.
Chapter 14 · Fire Protection
25
e-books by eatpl.in · © 2026 · Do not copy or distribute
Here are the two versions of the CARGO SMOKE panel, both shown after a smoke warning in the aft hold and a discharge. The red SMOKE light, with its ECAM warning, comes on if both channels detect smoke, or one detects smoke and the other channel is faulty. On the two-bottle panel, the guarded DISCH switch for each hold selects AGENT 1 or AGENT 2, the DISCH 1 and DISCH 2 lights show which bottle is empty, and the DISCH AGENT 2 light comes on sixty minutes after AGENT 1 and goes off when the AGENT 2 squib is fired. On the one-bottle panel, each hold has a guarded DISCH pushbutton. In both, the DISCH light comes on within sixty seconds when the bottle is fully discharged. The TEST pushbutton must be held for at least three seconds: it tests the detectors in sequence, flashes the SMOKE lights twice with the ECAM warning, closes the isolation valves and lights the DISCH lights.
Exam traps
Six things candidates get wrong Pushing ≠ discharging The ENG FIRE pb isolates and arms . Agent goes only when you push AGENT .
One loop is enough… if the other failed Fire + other loop failed = warning. Fire + other loop healthy and quiet is not.
Flame effect = 5 s Both loops breaking within 5 s is a fire warning, not two faults.
Only the APU fires itself Automatic discharge: APU, on the ground, 3 s after the warning. Never the engines.
Avionics smoke is a caution Single chime, MASTER CAUT, and GEN 1 LINE SMOKE , BLOWER and EXTRACT FAULT lights.
Red lights follow the warning FIRE pb red light comes on regardless of its position ; it goes out when the warning stops.
Chapter 14 · Fire Protection
26
e-books by eatpl.in · © 2026 · Do not copy or distribute
Before the summary, six classic traps. First, pushing the ENG FIRE pushbutton does not discharge anything; it isolates the engine and arms the squibs. Second, one loop alone can give a fire warning only if the other loop has failed; a healthy loop that stays quiet blocks the warning. Third, the flame effect window is five seconds. Fourth, the only bottle that fires by itself is the APU bottle, on the ground, three seconds after the warning. Fifth, avionics smoke is a caution with a single chime, and it lights GEN 1 LINE SMOKE and the BLOWER and EXTRACT FAULT lights. Sixth, the red light in a FIRE pushbutton follows the warning, not the position of the pushbutton, so a pushed-out button can still be red while the fire continues.
Summary
Fire protection on one page Detect Engines and APU: loops A + B and an FDU ; AND logic, OR with a failed loop, flame effect 5 s . Smoke: avionics, lavatories, cargo.
Alert Fire: CRC , MASTER WARN, red ECAM, red FIRE pb and ENG MASTER FIRE light. Avionics smoke: caution .
Isolate ENG FIRE pb: fuel, hydraulics, bleed, pack, FADEC, IDG . APU FIRE pb: APU off, fuel, APU bleed + X BLEED , APU GEN.
Extinguish Engine: 2 bottles , SQUIB white → push → DISCH amber. APU: 1 bottle, automatic on ground after 3 s .
Cargo Pairs of detectors, isolation valves close, fan stops. AGENT 1 ≈ 60 s; DISCH AGENT 2 at 60 min ; 1-bottle aircraft use DISCH pbs.
Test ENG and APU TEST give the full warning. APU test on ground > 3 s may stop the APU; cargo TEST: hold 3 s .
Chapter 14 · Fire Protection
27
e-books by eatpl.in · © 2026 · Do not copy or distribute
Let us pull it together with four verbs: detect, alert, isolate, extinguish. Engines and APU detect fire with two loops and a fire detection unit, using AND logic, OR logic when a loop has failed, and the five-second flame effect. Smoke is detected in the avionics bay, the lavatories and the cargo holds. A fire alert is the full warning, while avionics smoke is a caution. The ENG FIRE pushbutton isolates fuel, hydraulics, bleed, pack, FADEC and the I D G; the APU FIRE pushbutton isolates the APU, including its bleed and the crossbleed. You then discharge with the AGENT pushbuttons, watching SQUIB and DISCH, and the APU bottle fires itself on the ground after three seconds. In the cargo holds, ventilation is isolated, bottle one knocks the fire down and bottle two keeps it down. Well done.