Welcome to the fuel system of the A320. On a long sector the aircraft carries close to nineteen tonnes of fuel, and every kilogram of it has to be in the right tank at the right time: feeding the engines, cooling the generators, relieving the wing, and leaving the aircraft with a sensible balance at landing. In this lesson we follow the fuel from the tanks, through the pumps and valves, to the engines and the APU. We will learn the feed sequence and the automatic transfers that the system runs by itself, and then finish on the ground with refuelling and the inerting system. The next lesson then covers the cockpit panel, the ECAM page and the warnings.
Fuel system
Our route through ATA 28-10 1 Tanks 2 Pumps and feed 3 Transfers 4 Valves 5 APU and IDG 6 Refuelling 7 Inerting Store Wing inner and outer tanks, the centre tank, optional additional centre tanks, vents.
Feed Six tank pumps, sequence valves, the centre tank logic, crossfeed and LP valves.
Transfer Outer to inner, ACT to centre, and centre to inner on some aircraft.
Service APU feed, IDG recirculation, refuelling, defuelling and inerting.
Chapter 17 · Fuel System
2
e-books by eatpl.in · © 2026 · Do not copy or distribute
Here is our route through chapter twenty eight ten, the description of the fuel system. First we see where the fuel is stored and how much each tank holds, with a quick drill on litres and kilograms. Then we look at the pumps that feed the engines, the small sequence valves that decide which tank empties first, and the automatic logic of the centre tank pumps. Third come the transfers, which the system does for you: outer tank to inner tank, additional centre tanks to the centre, and on some aircraft centre to inner. Then the valves that the crew controls, the crossfeed and the LP valves, plus gravity feeding. We finish with the APU feed, the generator cooling loop, refuelling and the inerting system.
General
What the fuel system does Stores fuel In the wing tanks, the centre tank and, if installed, additional centre tanks.
Refuels correctly Puts the right quantity into each tank during refuelling.
Feeds engines and APU Supplies the two engines and the auxiliary power unit.
Cools the IDGs Circulates fuel to cool the integrated drive generators.
Transfers On some aircraft it controls transfer from the centre tank to the inner (wing) tanks.
Relieves the wing Keeps fuel in the outer tanks for wing bending and flutter relief.
Chapter 17 · Fuel System
3
e-books by eatpl.in · © 2026 · Do not copy or distribute
Before the details, let us be clear about what the fuel system is for. It stores the fuel, of course, in the wings, in the centre tank and in additional centre tanks if the aircraft has them. It puts the correct quantity into each tank during refuelling. It supplies fuel to the two engines and to the auxiliary power unit. It circulates fuel to cool the integrated drive generators, which is an easy one to forget. On some aircraft it controls the transfer of fuel from the centre tank into the wing tanks. And it keeps fuel in the outer tanks as long as possible, because weight far out on the wing reduces wing bending and helps against flutter. Keep that last point in mind: it explains the whole feed sequence.
Tanks
Where the fuel is stored Each wing: an inner tank and an outer tank A centre tank in the wing box, and up to two ACTs (additional centre tanks) if installed A vent surge tank outboard of each outer tank Full tanks allow 2 % expansion (a 20 °C rise) without spilling Overpressure protectors in each vent, outer and inner tank, and between the centre and left inner tankOUTER INNER CENTRE OUTER INNER ACT (optional) vent surge tank
Chapter 17 · Fuel System
4
e-books by eatpl.in · © 2026 · Do not copy or distribute
Let us look inside the wing. Each wing has two tanks: a small outer tank near the tip, and a large inner tank closer to the fuselage, which is the one that feeds the engine. Between the wings, in the wing box under the cabin floor, is the centre tank. Some aircraft also carry one or two additional centre tanks, called A C Ts, which never feed an engine directly. Outboard of each outer tank there is a vent surge tank, which catches any fuel that enters the vent system. When the aircraft is refuelled to maximum capacity, the fuel can still expand by two per cent, which is a twenty degree temperature rise, without spilling. Finally, overpressure protectors guard each vent, outer and inner tank, and the connection between the centre and left inner tank.
Capacity
How much fuel: litres and kilograms One A320 version: outer 880 L each, inner 6 924 L each, centre 8 250 L Each ACT adds 2 992 L (2 349 kg) The manual converts at 0.785 kg/L Total without ACT: 23 859 L , about 18 730 kg Figures differ slightly between versions; aircraft with a single wing tank hold about 7 750 L per wing Usable fuel per tank (one A320 version) 0 2 4 6 8 thousand litres 880 L 691 kg Outer (each) 6 924 L 5 435 kg Inner (each) 8 250 L 6 476 kg Centre 2 992 L 2 349 kg ACT (each) Without ACT: 23 859 L = 18 729 kg (at 0.785 kg/L)
Chapter 17 · Fuel System
5
e-books by eatpl.in · © 2026 · Do not copy or distribute
Now the numbers, using one A320 version as our example. Each outer tank holds eight hundred and eighty litres of usable fuel, each inner tank six thousand nine hundred and twenty four litres, and the centre tank eight thousand two hundred and fifty litres. Each additional centre tank adds two thousand nine hundred and ninety two litres. Notice how small the outer tanks are compared with the inner ones. The manual converts volume to mass at a density of zero point seven eight five kilograms per litre, which gives about eighteen thousand seven hundred and thirty kilograms without any additional tanks. Other versions differ by a few litres, and aircraft whose wing has a single tank hold about seven thousand seven hundred and fifty litres per wing. Learn the pattern, not every digit.
Worked examples
Litres, kilograms and density Question Working Answer Centre tank full: how many kg? 8 250 L × 0.785 kg/L ≈ 6 476 kg Uplift 10 000 kg: how many litres? 10 000 kg ÷ 0.785 kg/L ≈ 12 739 L Both outer tanks full: how many kg? 2 × 880 L × 0.785 ≈ 1 382 kg Expansion space when full (no ACT) 2 % of 23 859 L ≈ 477 L Same uplift if density is 0.80 10 000 ÷ 0.80 12 500 L: denser fuel, fewer litres
Fuel is planned in mass but loaded in volume: always check which unit the number is in.
Chapter 17 · Fuel System
6
e-books by eatpl.in · © 2026 · Do not copy or distribute
Let us practise, because fuel arithmetic is a classic interview question. A full centre tank is eight thousand two hundred and fifty litres; multiply by zero point seven eight five and you get about six thousand four hundred and seventy six kilograms. Going the other way, an uplift of ten thousand kilograms divided by zero point seven eight five is about twelve thousand seven hundred and forty litres. Both outer tanks together, two times eight hundred and eighty litres, make only about one thousand three hundred and eighty kilograms. The two per cent expansion space on a full aircraft without additional tanks is about four hundred and seventy seven litres. And if the fuel is denser, say zero point eight zero, the same ten thousand kilograms takes only twelve thousand five hundred litres.
Engine feed
The engine feed system at a glance LEFT OUTER LEFT INNER CENTRE RIGHT INNER RIGHT OUTER ENG 1 ENG 2 M M LP VALVE LP VALVE M X FEED VALVE double motor L1 L2 C1 C2 R1 R2 sequence valves APU APU pump APU LP valve transfer valves suction valve Version with centre tank pumps (six pumps). The orange glow shows the normal cruise feed: centre tank first.
Chapter 17 · Fuel System
7
e-books by eatpl.in · © 2026 · Do not copy or distribute
Here is our own drawing of the engine feed, for the common version with six main pumps. Read it from the bottom up. There are two pumps in each inner tank and two in the centre tank. The left inner pumps and centre pump one join a manifold that leads up to engine one. The right inner pumps and centre pump two lead to engine two. Each engine line has its low pressure, or L P, valve. Across the middle runs the crossfeed line with its valve, normally closed. The APU takes its fuel from the left side. Notice also the small sequence valves on the four wing pumps, the suction valves for gravity feeding, and two transfer valves in each wing between outer and inner tank. The glow shows normal cruise: the centre tank feeding both engines.
Tank pumps
Six pumps, and why the centre tank empties first Each engine is fed by one centre tank pump or two pumps in its own inner tank All wing tank pumps stay on for the whole flightWing pumps have pressure relief sequence valves So with all pumps running, the centre pumps deliver first On aircraft without centre pumps, two pumps in each inner tank feed the engines (four pumps) LEFT OUTER LEFT INNER CENTRE RIGHT INNER RIGHT OUTER ENG 1 ENG 2 M M LP VALVE LP VALVE M X FEED VALVE double motor L1 L2 C1 C2 R1 R2 sequence valves APU APU pump APU LP valve transfer valves suction valve When all six pumps run, the centre pumps win: the wing pump sequence valves let them deliver first
Chapter 17 · Fuel System
8
e-books by eatpl.in · © 2026 · Do not copy or distribute
On this version each engine can be fed either by one centre tank pump, or by the two pumps in the inner tank on its own side. Now an important detail: the wing tank pumps are never switched off in normal operation. They run for the whole flight. So how does the centre tank get used first? The answer is the pressure relief sequence valves on the wing pump outlets. A wing pump can only push fuel into the manifold when the manifold pressure is lower than its sequence valve setting. While a centre pump is running, it holds the pressure higher, so it delivers preferentially and the wing fuel stays in the wing. The moment the centre pump stops, the wing pumps take over with no gap. Some aircraft have no centre pumps at all; they use four wing pumps.
Centre tank pumps
The centre tank pump logic in AUTO MODE SEL at AUTO : the pumps run for 2 min at engine start Before or after the start, they run only when the slats are retracted They stop when the inner tank is full and restart once about 500 kg has been used (underfull sensor) They stop 5 min after the centre tank reaches low level MAN: the pumps run; the crew must switch them OFF when the centre tank is empty Centre tank pumps in AUTO 1 Engine start run for 2 minutes 2 Slats extended (taxi, take-off) stopped: wings feed 3 Slats retracted run: centre feeds 4 Inner tank full (recirculation) stop 5 About 500 kg used from inner restart (underfull sensor) 6 Centre tank at low level stop 5 min later MAN: the pumps simply run. Switch them OFF yourself when the centre tank is empty.
Chapter 17 · Fuel System
9
e-books by eatpl.in · © 2026 · Do not copy or distribute
The centre tank pumps are controlled automatically when the mode selector is in AUTO. At engine start they run for two minutes. Apart from that, they run only when the slats are retracted, which means that taxi, take-off and landing are flown on wing tank fuel, and the centre tank feeds in the clean configuration. Each centre pump also stops when its associated inner tank becomes full, and restarts once the engines have used about five hundred kilograms from that inner tank, when the fuel reaches the underfull sensors. You will see why the inner tank refills in a moment. When the centre tank reaches its low level, the pumps stop five minutes later. In manual mode the pumps simply run, so the crew must switch them off when the centre tank is empty.
Fuel recirculation
IDG cooling: fuel that comes back Some fuel leaves the engine HP fuel line , cools the IDG and returns to the outer tank Used when IDG oil is hot or at low engine power The FADEC controls the fuel return valve Outer tank full: fuel spills into the inner tank So while the centre tank feeds, the inner tanks tend to overfill , which is why the centre pumps stop when the inner is full Inner tank Outer tank LP pump HP pump To the burners IDG cooler Fuel return valve (FADEC) spill pipe if the outer is full warm fuel back to the tank IDG oil cooled
Chapter 17 · Fuel System
10
e-books by eatpl.in · © 2026 · Do not copy or distribute
Here is the link that explains the centre pump logic. Each engine is supplied from its inner tank, or from the centre. But some of that fuel, after the engine's high pressure pump, passes through the integrated drive generator heat exchanger, where it picks up heat, and then returns through the fuel return valve to the outer tank. The FADEC controls that valve, and the loop runs when the generator oil is hot or at low engine power. If the outer tank is already full, the fuel spills over into the inner tank. Now picture the centre tank feeding: the engines are not using inner tank fuel, but warm fuel keeps arriving. So the inner tank fills up, the centre pump stops, the inner tank feeds for about five hundred kilograms, and the cycle repeats.
Feed sequence
Which tank empties first 1. ACT 2 , then 2. ACT 1 : transfer into the centre tank3. Centre tank (slats retracted)4. Inner tanks , each down to 750 kg 5. Outer tanks : their fuel drains into the inner tanksResult: fuel stays in the outer wing as long as possible 0 1000 2000 3000 4000 5000 6000 0 60 120 180 240 300 minutes after engine start (simplified) kg per tank inner low level 750 kg Centre Inner (each) Outer (each) slats in centre empty transfer
Chapter 17 · Fuel System
11
e-books by eatpl.in · © 2026 · Do not copy or distribute
Put the pieces together and you get the feed sequence. If additional centre tanks are fitted, A C T two empties first and then A C T one, both by transferring into the centre tank. Then the centre tank feeds the engines. Then the inner tanks feed, each one down to seven hundred and fifty kilograms. Only then does the fuel in the outer tanks drain into the inner tanks. The graph shows a simplified flight: the inner tanks feed taxi and take-off, the centre tank takes over once the slats are in, and its line falls to zero. The inner tanks then fall to the dashed low level line, and at that point the outer tanks empty into them, which is the little rise you see on the inner line. The outer wing stays heavy for most of the flight.
Outer to inner transfer
Outer tank fuel: the last to be used Two transfer valves in each wingThey open when an inner tank reaches low level, about 750 kg Each of the two low-level sensors in an inner tank opens one valve in each wing : both wings transfer together Once open they latch open until the next refuelling Steep descent or strong acceleration can open them early , with a possible low level warning INNER TANK OUTER TANK low level about 750 kg two transfer valves in each wing Valves open together in both wings, then latch open They close again only at the next refuelling
Chapter 17 · Fuel System
12
e-books by eatpl.in · © 2026 · Do not copy or distribute
Let us watch the outer to inner transfer happen. The inner tank pumps keep feeding the engine, and the level falls. When it reaches about seven hundred and fifty kilograms, the low level sensor goes dry. That signal opens the transfer valves, and the outer tank fuel drains by gravity into the inner tank. There are two valves in each wing and two sensors in each inner tank, and each sensor controls two valves, one in each wing, so both wings always transfer together. Once open, the valves latch open, and they only close again automatically at the next refuelling. One caution: the seven hundred and fifty kilogram figure assumes a level attitude without acceleration. In a steep descent or a strong acceleration the valves may open with more fuel, and a low level warning may even come on.
Centre tank transfer (some aircraft)
No centre pumps: jet pump transfer On some aircraft only the inner (wing) tanks feed the engines The centre fuel is transferred into them by jet pumps Opening a transfer valve sends wing pump fuel through the jet pump; its suction moves centre fuel The FLSCU closes the valve when the wing tank is full and reopens it after 500 kg is used (250 kg with single wing tanks) MAN: crew uses CTR TK XFR ; select OFF when the wing tanks are full and when the centre is empty CENTRE TANK INNER (WING) TANK tank pump M transfer valve jet suction draws centre fuel motive flow FLSCU closes the valve when the inner tank is full and reopens it after about 500 kg is used (250 kg on aircraft with single wing tanks).
Chapter 17 · Fuel System
13
e-books by eatpl.in · © 2026 · Do not copy or distribute
Some aircraft in the fleet have no centre tank pumps. On these, only the wing tanks feed the engines, and the centre fuel is moved into them instead. The trick is a jet pump in the centre tank. When the transfer valve opens, fuel from the wing tank pump flows through the jet pump, and that flow creates suction, which draws centre tank fuel across into the wing tank. The fuel level sensing control unit, the F L S C U, controls the valves automatically. It closes a valve when its wing tank is full, and reopens it when the engines have used about five hundred kilograms, or two hundred and fifty kilograms on aircraft with a single wing tank. In manual mode the crew opens the valves and must close them when the wing tanks are full, and when the centre is empty.
Additional centre tanks
ACT to centre tank transfer ACT fuel is pushed by air pressure : the ACT vent valve closes and the air shutoff valve opens Starts automatically after take-off at slat retraction , if the centre high-level sensor has been dry for 10 min ACT 2 first , then ACT 1, through the ACT transfer valve and inlet valvesStops if the centre high level goes wet ; resumes after 10 min dry ACT pb FWD : manual transfer with the ACT transfer pump ; back to AUTO when empty ACT 2 empties first ACT 1 then this one CENTRE TANK inlet valves transfer valve air shutoff valve opens: ACTs pressurised AUTO transfer starts when ALL are true: in flight, slats retracted at least one ACT low-level sensor wet centre tank high-level sensor dry for 10 min It stops as soon as one is no longer true.
Chapter 17 · Fuel System
14
e-books by eatpl.in · © 2026 · Do not copy or distribute
Additional centre tanks, if installed, never feed an engine directly. Their fuel is moved forward into the centre tank. The method is air pressure. The system closes the A C T vent valve and opens the air shutoff valve, so the tank is pressurised and its fuel is pushed out through the inlet valve and the A C T transfer valve. The transfer starts automatically after take-off, at slat retraction, provided the centre tank high level sensor has been dry for ten minutes and the tank is not empty. With two tanks, A C T two goes first, then A C T one. If the centre high level sensor becomes wet, transfer stops, and it resumes after ten more minutes dry. The crew can also select the A C T pushbutton to forward, which starts the A C T transfer pump.
Suction valves
Gravity feed when the pumps fail Each wing has suction valves bypassing the pumps In normal operation pump pressure holds them closed If the inner tank pumps fail, they open and the engine is fed by gravity Centre tank pumps have no suction valves So no gravity feeding from the centre tank : if both centre pumps fail, that fuel cannot be used LEFT OUTER LEFT INNER CENTRE RIGHT INNER RIGHT OUTER ENG 1 ENG 2 M M LP VALVE LP VALVE M X FEED VALVE double motor L1 L2 C1 C2 R1 R2 sequence valves APU APU pump APU LP valve transfer valves suction valve Pumps failed: the suction valve opens, gravity feeds
Chapter 17 · Fuel System
15
e-books by eatpl.in · © 2026 · Do not copy or distribute
What if the tank pumps stop? Each wing has suction valves in a bypass around the pumps. Normally the tank pump delivers and its pressure holds the suction valve shut. Now watch the pump fail: the feed pressure drops, the suction valve opens, and the engine is fed by gravity, sucking fuel through the bypass. Gravity feeding is the back-up that keeps the engine running without its pumps. And here is the trap that examiners love. The centre tank pumps are not fitted with suction valves. So there is no gravity feeding from the centre tank. If both centre tank pumps fail, whatever fuel is left in the centre tank cannot be used, and on the ECAM page that quantity is shown boxed in amber.
Crossfeed
The crossfeed valve One crossfeed valve in the line joining the two engine feeds Driven by a double motor Lets both engines be fed from one side Or one engine be fed from both sides Normally closed ; opened with the X FEED pb on the FUEL panel LEFT OUTER LEFT INNER CENTRE RIGHT INNER RIGHT OUTER ENG 1 ENG 2 M M LP VALVE LP VALVE M X FEED VALVE double motor L1 L2 C1 C2 R1 R2 sequence valves APU APU pump APU LP valve transfer valves suction valve
Chapter 17 · Fuel System
16
e-books by eatpl.in · © 2026 · Do not copy or distribute
Normally each engine lives on its own side. The crossfeed valve sits in the line that joins the two engine feeds, and it is controlled by a double motor. With the crossfeed valve open, the system can do two things. Both engines can be fed from one side, as you see here, with the left inner tank feeding engine one as normal, then through the crossfeed to engine two as well. Or one engine can be fed from both sides, for example after an engine shutdown, so that the live engine can use fuel from both wings. The valve is normally closed and the crew opens it with the X FEED pushbutton on the FUEL panel, which we meet in the next lesson.
Engine LP valves
Stopping the fuel to an engine Each engine has a low pressure (LP) fuel valve It stops the fuel flow to that engine Closed by the ENG MASTER switch selected OFF Or by pushing the ENG FIRE pushbutton The APU has its own APU LP valve to the engine LP VALVE closed ENG 1 FIRE ENG FIRE pb ENG 1 OFF ENG MASTER switch either one closes it
Chapter 17 · Fuel System
17
e-books by eatpl.in · © 2026 · Do not copy or distribute
Each engine feed line has a low pressure fuel valve, the L P valve, where the fuel leaves the aircraft fuel system and enters the engine. Closing it stops the fuel flow to that engine. There are two ways to close it. The first is the engine master switch: every normal engine shutdown on the stand closes the L P valve. The second is the engine fire pushbutton: in a fire, pushing it isolates the engine, and closing the L P valve is one of the things it does, so no more fuel is pumped into the fire zone. The APU has its own A P U L P valve in its feed line. On the ECAM fuel page you can see each L P valve, and the next lesson shows how its colour tells you whether it agrees with the master switch.
The APU is supplied from the left fuel feed line Normally the tank pumps provide the pressure An APU fuel pump starts automatically when feed pressure is low : tank pumps lost or off, or no normal AC It runs off AC ESS SHED , or the AC STAT INV BUS if that fails The APU feed line has its own APU LP valve left feed line APU fuel pump starts if pressure low APU LP valve APU APU pump power normally AC ESS SHED else AC STAT INV BUS Pump runs when tank pumps lost or off, or no normal AC
Chapter 17 · Fuel System
18
e-books by eatpl.in · © 2026 · Do not copy or distribute
The auxiliary power unit sits in the tail cone, and it takes its fuel from the left fuel feed line, then through a long line aft to the tail. Normally the tank pumps provide all the pressure the APU needs. But think of a cold aircraft on batteries only, or a flight where the tank pumps have been lost. For those cases there is a special APU fuel pump, which starts automatically whenever the feed pressure is low. It normally runs off the AC essential shed bus, but if that bus fails it runs off the AC static inverter bus. So even on batteries alone, with no normal AC, the pump still has a power supply. The APU line also has its own APU L P valve. We will see more of this in the APU lesson.
Refuelling
Pressure refuelling A gallery joins the refuel coupling to each tank's refuel valve Normally automatic : set the load on the preselector ; manual control is also possible Auto fill starts with the outer tanks ; the centre fills at the same time if the load needs it A full outer tank spills into the inner tank Valves close at the preselected load or at high level ; battery power is enough Refuel coupling under the wing refuel gallery L OUTER CENTRE R OUTER refuel valves INNER INNER spill pipe outer to inner Auto: set the load on the preselector valves close at that load or at high level battery power is enough gravity: overwing points
Chapter 17 · Fuel System
19
e-books by eatpl.in · © 2026 · Do not copy or distribute
Refuelling is normally done under pressure through a coupling under the wing. One coupling, or two on aircraft with refuelling points on both sides, connects to a gallery that runs to the refuel valve of each tank. The normal method is automatic: the refueller sets the required total on the preselector, and the system does the rest. Fuel goes first into the outer tanks, and as each outer tank fills it overflows into its inner tank through a spill pipe. If the load is larger than the wings can hold, the centre tank fills at the same time. Each refuel valve closes when the tanks hold the preselected load, or when a sensor detects high level. Nice detail: the aircraft can be refuelled with only battery power. The wing tanks can also be filled by gravity, through overwing points.
Refuelling and defuelling
Refuelling details worth knowing Topic What the system does Automatic, aircraft with ACTs ACTs, centre and outer cells fill together; outer overflows into inner Manual refuelling order Wing tanks first, then the centre tank, then the ACTs Electrical transients Switching between APU, external and engine power may stop auto refuel: re-enter the preselected quantity Refuel panel location Fuselage side beneath the right wing, or under the wing next to the coupling Transfer (defuel) valve Joins engine feed and refuel gallery: tank pumps can move fuel tank to tank, or defuel Typical times at nominal pressure Wings 17 min · all tanks 20 min · with 1 ACT 25 min · with 2 ACTs 27 min
The refuel control panel itself is covered in the next lesson.
Chapter 17 · Fuel System
20
e-books by eatpl.in · © 2026 · Do not copy or distribute
A few more refuelling facts round this out. With additional centre tanks fitted, automatic refuelling fills the A C Ts, the centre tank and the outer cells together, and the outer cells overflow into the inner cells. If you ever refuel manually, the order is wing tanks first, then the centre tank, then the A C Ts. Electrical transients, for example switching from external power to the APU during refuelling, may stop the automatic process, and then the preselected quantity has to be entered again. The refuel panel is on the fuselage side beneath the right wing, or under the wing beside the coupling. A transfer valve between the engine feed and the refuel gallery lets the tank pumps move fuel from one tank to another, or defuel the aircraft. Typical times run from seventeen to twenty seven minutes.
Fuel tank inerting
Making the centre tank safer Fitted on some aircraft: reduces flammability in the tank most exposed, the centre tank In the belly fairing : a CSAS (conditioned service air system) and an IGGS (inert gas generation system) Engine bleed air is conditioned, then an air separation module removes oxygen Air with less than 12 % oxygen replaces the air above the fuel No crew action : works from engine start until engine stopEngine bleed air CSAS conditions air IGGS air separation O2 under 12 % CENTRE TANK ullage inerted oxygen-rich air out Only the centre tank: the only one with high flammability exposure Installed in the belly fairing (on aircraft so fitted) No crew action: runs from engine start to engine stop
Chapter 17 · Fuel System
21
e-books by eatpl.in · © 2026 · Do not copy or distribute
The last system in this lesson is the fuel tank inerting system, fitted on some aircraft. Its aim is to reduce the flammability of the fuel tank that is most exposed to it, and that is the centre tank. It is the only tank with a high flammability exposure, so the other tanks do not need it. The equipment is installed in the belly fairing and has two parts. The conditioned service air system takes some engine bleed air and brings it to the right pressure and temperature. The inert gas generation system then passes it through an air separation module, which removes oxygen. The result is oxygen depleted air, with less than twelve per cent oxygen, which replaces the ambient air in the centre tank. The crew does nothing: it works by itself from engine start to engine stop.
Exam traps
What happens if… Situation Result Both centre tank pumps fail (six-pump version) Centre fuel unusable: no suction valves, so no gravity feed Both pumps in one inner tank fail That engine is gravity fed through the suction valves, or use crossfeed Steep descent with about 800 kg in each inner Transfer valves may open early; low level warning possible Outer transfer valves opened in flight They stay latched open until the next refuelling MODE SEL in MAN while the centre feeds on the ground No auto stop: wing tanks can overflow if the centre pumps stay on Batteries only, APU start APU fuel pump runs from the AC STAT INV BUS
Chapter 17 · Fuel System
22
e-books by eatpl.in · © 2026 · Do not copy or distribute
Let us finish the theory with the questions that catch people out. If both centre tank pumps fail, the centre fuel is unusable, because there are no suction valves and so no gravity feeding from the centre. If both pumps in one inner tank fail, that engine can still be gravity fed through the suction valves, or the crew can use the crossfeed. In a steep descent with a little over seven hundred and fifty kilograms in the inner tanks, the transfer valves may open early, and a low level warning may appear. Once opened, those valves stay latched until the next refuelling. With the mode selector in manual on the ground and the centre tank feeding, nothing stops the pumps when the wings are full, so the wing tanks can overflow. And for an APU start on batteries, the static inverter powers the APU pump.
Summary
The fuel system in one page Tanks Inner and outer in each wing, centre, optional ACTs, vent surge tanks; 0.785 kg/L.
Pumps Two per inner tank, two in the centre (some aircraft none); wing pumps always on, sequence valves.
Centre logic 2 min at start, then slats retracted only; stops when inner full, restarts after 500 kg; stops 5 min after low level.
Sequence ACT 2, ACT 1, centre, inner to 750 kg, then outer drains into inner (valves latch).
Valves Crossfeed (double motor), LP valves (master or fire pb), suction valves (no gravity from centre).
Service APU from the left line with its own pump; IDG fuel returns to the outer tank; battery refuelling; inerting.
Chapter 17 · Fuel System
23
e-books by eatpl.in · © 2026 · Do not copy or distribute
Let us wrap up. Fuel is stored in an inner and an outer tank in each wing, in the centre tank and in optional additional centre tanks, with a vent surge tank at each wing tip. On the six pump version, two pumps sit in each inner tank and two in the centre; the wing pumps stay on all flight and their sequence valves let the centre feed first. The centre pumps run two minutes at engine start, then only with the slats retracted, and they stop when the inner tank is full or five minutes after low level. The sequence is A C T two, A C T one, centre, inner down to seven hundred and fifty kilograms, then outer. And remember the valves, the APU feed and the recirculation loop. Next lesson: the panel and the ECAM.