A320 Aircraft Systems · Chapter 5
Hydraulic Controls, Indications and Failures The HYD overhead panel, the maintenance panel, the ECAM HYD page and memos, and what the crew loses when one or two hydraulic systems fail.
GREEN BLUE YELLOW PTU ENG 1 PUMP RAT MAN ON ELEC PUMP ENG 2 PUMP ELEC PUMP FAULT OFF FAULT OFF FAULT OFF FAULT OFF FAULT ON A U T O A U T O H Y D HYD GREEN 3000 BLUE 3000 YELLOW 3000 PSI PSI PTU RAT ELEC 1 2 ELEC TAT +19 °C SAT +18 °C 23 H 56 GW 60300 KG © 2026 eatpl.in. For the personal study of eatpl.in students only. Do not copy or distribute.
e-books by eatpl.in · © 2026 · Do not copy or distribute
In the last lesson we built the three hydraulic systems from the reservoir up. Now we move into the cockpit. We will go through every pushbutton on the HYD overhead panel and exactly when its FAULT light comes on, the RAT MAN ON button, and the two maintenance panel switches you may meet on the ground. Then we will read the ECAM HYD page symbol by symbol, and the memos. Finally we put it all together: what you see when something fails, and which users you lose with one or two systems gone. Keep the green, blue and yellow picture from last time in mind. This is the part of the hydraulics that examiners and simulator instructors test the hardest.
Hydraulic controls
Our route through ATA 29-20 GREEN BLUE YELLOW PTU ENG 1 PUMP RAT MAN ON ELEC PUMP ENG 2 PUMP ELEC PUMP FAULT OFF FAULT OFF FAULT OFF FAULT OFF FAULT ON A U T O A U T O H Y D Overhead panel ENG 1 and 2 PUMP, blue and yellow ELEC PUMP, PTU, RAT MAN ON.
Maintenance panel BLUE PUMP OVRD and the three LEAK MEASUREMENT VALVES.
ECAM HYD page Labels, pressures, pumps, PTU, RAT, valves, reservoirs and memos.
Failures The cockpit picture, and the users lost with one or two systems gone.
Chapter 5 · Hydraulic Controls, Indications and Failures
2
e-books by eatpl.in · © 2026 · Do not copy or distribute
Here is our route through chapter twenty nine twenty. First the HYD panel on the overhead: two engine pump buttons, the blue and yellow electric pump buttons, the power transfer unit button and the RAT MAN ON button. For each one we will learn its positions and exactly what turns on its FAULT light. Second, the two small switches on the maintenance panel, which you may use on the ground. Third, the ECAM HYD page, which is the most information-dense part of the lesson, so we will take it piece by piece, plus the two hydraulic memos. And last, failures: what the crew sees when something goes wrong, and which users are lost when one system, or two systems, are gone. Keep the previous lesson's distribution table nearby.
Overhead panel
The HYD panel GREEN BLUE YELLOW PTU ENG 1 PUMP RAT MAN ON ELEC PUMP ENG 2 PUMP ELEC PUMP FAULT OFF FAULT OFF FAULT OFF FAULT OFF FAULT ON A U T O A U T O H Y D 1 2 3 1 4 5 Normal flight: all lights out. 1 ENG PUMPs · 2 blue ELEC PUMP · 3 PTU · 4 yellow ELEC PUMP · 5 RAT MAN ON
Chapter 5 · Hydraulic Controls, Indications and Failures
3
e-books by eatpl.in · © 2026 · Do not copy or distribute
This is the HYD panel on the overhead, drawn as a mimic of the three systems. Read it left to right. Engine one pump feeds the green line, the RAT MAN ON button feeds the blue line, then the blue electric pump, the power transfer unit sitting on the line between green and yellow, the engine two pump on yellow, and finally the yellow electric pump. Notice the dark cockpit idea: in normal flight every light is out. The engine pump buttons are simply on, the blue electric pump and the power transfer unit sit at AUTO, and the yellow electric pump is off. The blue electric pump and the RAT MAN ON button are guarded, so they cannot be pressed by accident. Any light on this panel is therefore telling you something.
ENG 1 (2) PUMP pb
Engine pump pushbuttons On (lights out): the pump pressurises its system when the engine runsOFF : the pump is depressurised and stops generatingAmber FAULT + ECAM caution: reservoir low level , overheat or low air pressure , or pump low pressure Pump low pressure is inhibited on the ground with the engine stopped FAULT goes out when OFF is selected, except for an overheat ENG 1 PUMP FAULT OFF ON normal: all out FAULT OFF FAULT + OFF selected off, still lit FAULT OFF FAULT pump or reservoir fault FAULT logic: reservoir level low, overheat, low air pressure pump pressure low (not on ground, engine stopped) goes out at OFF, except overheat
Chapter 5 · Hydraulic Controls, Indications and Failures
4
e-books by eatpl.in · © 2026 · Do not copy or distribute
The engine pump buttons, one for green and one for yellow, are normally on, with all lights out. In that state the pump pressurises its system whenever its engine is running. Press it and the white OFF light comes on; the pump is depressurised and stops generating hydraulic power. The amber FAULT light comes on, together with an ECAM caution, for four reasons. Three are about the reservoir: low fluid level, overheat, or low air pressure. The fourth is low pump pressure, and that one is inhibited on the ground when the engine is stopped, otherwise it would be lit at every turnaround. When the crew selects OFF, the FAULT light goes out, with one exception: an overheat. Then the light stays on for as long as the overheat lasts.
BLUE ELEC PUMP pb
The blue electric pump pushbutton Guarded; normally at AUTO (lights out) AUTO with AC power: runs in flight , and on the ground if one engine is running or BLUE PUMP OVRD is pressedOFF : the pump is de-energisedFAULT: reservoir low level, overheat, low air pressure, pump low pressure (inhibited on the ground, engines stopped) or pump overheat FAULT goes out at OFF, except for an overheat BLUE ELEC PUMP (guarded) FAULT OFF AUTO normal: all out FAULT OFF OFF pump de-energised FAULT OFF FAULT + OFF overheat persists FAULT logic: reservoir level low, overheat, low air pressure pump pressure low (not on ground, engines stopped) pump overheat: the extra cause
Chapter 5 · Hydraulic Controls, Indications and Failures
5
e-books by eatpl.in · © 2026 · Do not copy or distribute
The blue electric pump button is guarded and normally sits at AUTO, all lights out. At AUTO, and provided AC power is available, the pump runs in flight. On the ground it runs only if one engine is running, or if someone has pressed the BLUE PUMP OVRD switch on the maintenance panel. Selecting OFF de-energises the pump. The FAULT light has the same reservoir causes as the engine pumps, low level, overheat and low air pressure, and the same pump low pressure cause, inhibited on the ground with the engines stopped. But because it is an electric motor, there is one extra cause: pump overheat. And again, selecting OFF puts the light out unless there is an overheat, in which case it stays on as long as the overheat lasts.
Blue pump logic
When does the blue pump run? No AC power: never In flight at AUTO: always Ground, both engines stopped: no , unless BLUE PUMP OVRD is ON Ground, first engine started : yes So blue normally comes up when the first engine starts BLUE ELEC PUMP pb: AUTO AC power available? no In flight? yes on ground One engine running or BLUE PUMP OVRD ON? yes no Pump OFF Pump RUNS
Chapter 5 · Hydraulic Controls, Indications and Failures
6
e-books by eatpl.in · © 2026 · Do not copy or distribute
Let us turn the blue pump logic into a simple decision tree, because it is a classic interview question. Start with the pushbutton at AUTO. Is AC power available? If not, the pump cannot run, full stop. If it is, ask whether you are in flight. In flight, the pump runs. On the ground, it runs only if at least one engine is running, or if the BLUE PUMP OVRD switch on the maintenance panel is on. So here is the practical picture. At the gate with external power and both engines stopped, blue is not pressurised. As soon as the first engine is running, blue comes up. And if maintenance needs blue pressure with the engines off, they use the override. Try it on yourself: APU running, engines off, override off. The answer is no blue.
YELLOW ELEC PUMP pb
The yellow electric pump pushbutton ON (blue light): the pump runsIf its electrical supply is removed, it stays off when power comes back Off (lights out): pump off, but it starts automatically for the cargo doors Door operation inhibits other yellow users except alternate braking and ENG 2 reverse FAULT: reservoir low level, low air pressure, overheat; pump low pressure; pump overheat. Out at OFF except overheat YELLOW ELEC PUMP FAULT ON Off normal: all out FAULT ON ON pump running FAULT ON FAULT + ON fault Ground use: yellow (and green via the PTU) power interrupted: pump stays off afterwards cargo door lever: pump starts on its own FAULT out at OFF, except overheat
Chapter 5 · Hydraulic Controls, Indications and Failures
7
e-books by eatpl.in · © 2026 · Do not copy or distribute
The yellow electric pump button is normally off, with all lights out. Press it and the blue ON light comes on and the pump runs. That is what you use on the ground to get yellow pressure, and through the power transfer unit, green pressure too. One subtle point: if the electrical supply is removed while it is on, the pump will remain off when power comes back, so you have to select it again. With the button off, the pump still starts by itself when someone moves the cargo door selector lever, and then the other yellow users are inhibited, except alternate braking and the engine two reverser. The FAULT light covers the reservoir, low pump pressure and pump overheat, and as usual it goes out at OFF unless there is an overheat.
AUTO : PTU armed, green and yellow electrohydraulic valves open ; runs above 500 PSI differenceInhibited during the first engine start , tested during the second OFF : both valves close, power transfer stopsFAULT: green or yellow reservoir overheat , low air pressure or low fluid level No FAULT for a pump failure: that is exactly when the PTU is needed PTU FAULT OFF AUTO armed: all out FAULT OFF OFF valves closed FAULT OFF FAULT G or Y reservoir FAULT logic (green or yellow reservoir): overheat, low air pressure, low fluid level goes out at OFF, except overheat not lit for an engine pump failure
Chapter 5 · Hydraulic Controls, Indications and Failures
8
e-books by eatpl.in · © 2026 · Do not copy or distribute
The power transfer unit button normally sits at AUTO with all lights out. At AUTO the unit is armed, and both its green and yellow electrohydraulic valves are open. It runs automatically whenever the difference between green and yellow is more than five hundred P S I: in this scene green falls, the unit wakes up, the yellow side works as a motor, and green pressure restores. Remember it is inhibited during the first engine start and tested during the second. Selecting OFF closes both valves, and transfer stops. Now the FAULT light, which is a favourite trick question. It comes on for a reservoir problem on either side: green or yellow reservoir overheat, low air pressure, or low fluid level. It does not come on for an engine pump failure, because that is exactly the situation in which you want the unit to keep working.
Guarded pushbutton, no light Press it to extend the RAT at any time The RAT also extends automatically if AC BUS 1 and AC BUS 2 are lost HYD page: RAT white stowed, green out, amber stow pressure or pump not available Memo RAT OUT ; stowing is a ground job RAT MAN ON guarded pb, no light RAT stowed RAT not stowed RAT stow pressure / pump n/a HYD page RAT symbol Manual: press RAT MAN ON at any time Automatic: AC BUS 1 and AC BUS 2 both lost Stow: on the ground only Memo: RAT OUT (green; amber in phases 1 and 2)
Chapter 5 · Hydraulic Controls, Indications and Failures
9
e-books by eatpl.in · © 2026 · Do not copy or distribute
The RAT MAN ON button is a guarded pushbutton with no light. Lift the guard and press it, and the ram air turbine extends. The crew can do this at any time. The RAT also extends by itself if both AC bus one and AC bus two are lost, so in a total electrical failure you do not need to touch this button. Watch the strut drop out into the airflow, the turbine spin up and the pump bring blue to two thousand five hundred P S I. On the HYD page, the RAT symbol shows white while stowed, green when it is not stowed, and amber if pressure for stowing has been applied or the RAT pump is not available. A RAT OUT memo also appears. And remember: once out, it can be stowed only on the ground.
Maintenance panel
BLUE PUMP OVRD and leak measurement valves BLUE PUMP OVRD (guarded) ON: the blue electric pump runs, if the HYD panel ELEC PUMP pb is at AUTO Used to get blue pressure on the ground with the engines stopped LEAK MEASUREMENT VALVES B, G, Y (guarded)OFF: the valve closes and shuts off hydraulic supply to the primary flight controls On: the valve reopens, normal supply HYD BLUE PUMP OVRD LEAK MEASUREMENT VALVES B OFF G OFF Y OFF ON all four switches are guarded BLUE PUMP OVRD ON runs the blue electric pump on the ground if its HYD panel pb is at AUTO LEAK MEAS. OFF valve closes: hydraulic supply to the primary flight controls shut off on: normal supply
Chapter 5 · Hydraulic Controls, Indications and Failures
10
e-books by eatpl.in · © 2026 · Do not copy or distribute
The maintenance panel carries four guarded switches in its HYD section. The first is BLUE PUMP OVRD. With it on, the blue electric pump runs, but only if the blue ELEC PUMP button on the overhead is at AUTO. That is the way to get blue pressure on the ground with both engines stopped, for example for maintenance checks of the flight controls. The other three are the leak measurement valve switches, labelled B, G and Y. Selecting one OFF closes that system's electrohydraulic valve and shuts off hydraulic supply to the primary flight controls, so the engineers can measure leakage. Selecting it back on reopens the valve and restores normal supply. These are ground and maintenance tools; in normal line flying you should find them all in their normal positions.
ECAM HYD page
The ECAM HYD page HYD GREEN 3000 BLUE 3000 YELLOW 3000 PSI PSI PTU RAT ELEC 1 2 ELEC TAT +19 °C SAT +18 °C 23 H 56 GW 60300 KG 1 System label: white, amber below 1 450 PSI 2 System pressure (green; amber below 1 450 PSI) 3 PTU: armed, transferring, or OFF 4 RAT: stowed, out, or amber 5 Yellow ELEC pump: off, on, on with low pressure 6 Engine pump: in line, cross line, or LO; number amber if N2 below idle 7 Blue ELEC pump, ELEC legend, OVHT 8 Fire valve: in line open, amber cross line closed 9 Reservoir: quantity, LO AIR PRESS, OVHT
Chapter 5 · Hydraulic Controls, Indications and Failures
11
e-books by eatpl.in · © 2026 · Do not copy or distribute
Here is the ECAM HYD system page as you see it in normal flight. It is laid out like the systems themselves: green on the left, blue in the middle, yellow on the right, users at the top and reservoirs at the bottom. At the top are the system labels and pressures, three thousand P S I each. The power transfer unit line runs across between green and yellow, hopping over blue. The RAT points into the blue line, and the yellow electric pump symbol points into the yellow line. Further down are the engine pump boxes with their numbers, the blue electric pump box, the two fire valves, and at the bottom the three reservoir quantity scales. Let us now go through these numbered items one group at a time.
HYD page: systems and reservoirs
Labels, pressures and reservoirs System label white and triangle green above 1 450 PSI; both amber below System pressure figure green , amber below 1 450 PSI Reservoir quantity green ; amber below the low-level warning LO AIR PRESS amber + ECAM caution: reservoir air pressure below normalOVHT amber + ECAM caution: returning fluid too hot at the reservoir inletHYD GREEN 3000 BLUE 3000 YELLOW 1200 PSI PSI PTU RAT ELEC 1 2 ELEC OVHT LO AIR PRESS TAT +19 °C SAT +18 °C 23 H 56 GW 60300 KG
Chapter 5 · Hydraulic Controls, Indications and Failures
12
e-books by eatpl.in · © 2026 · Do not copy or distribute
Start at the top and bottom of the page. The system label, such as YELLOW, is white, and the small triangle below it is green, as long as the pressure is above one thousand four hundred and fifty P S I. Below that both turn amber, and so does the pressure figure, which is normally green. In this example yellow has dropped to one thousand two hundred, so its label, triangle, figure and line are all amber. Now the reservoirs. The quantity indication is green, and turns amber once the level goes below the warning level, as on the yellow reservoir here. LO AIR PRESS appears in amber with an ECAM caution when reservoir air pressure is low, and OVHT appears in amber with a caution when the fluid returning to the reservoir is too hot, as on green here.
HYD page: pumps and valves
Pump and valve symbols Engine pump: in line green = on and normal; cross line amber = pb OFF; LO amber = on but low pressure Pump number amber when that engine's N2 is below idle Fire valve: in line green not fully closed; cross line amber fully closed ELEC legend amber: that electric pump's power supply has failedOVHT beside the blue or yellow ELEC pump: pump overheatENGINE PUMP in line pb on, pressure normal cross line pb OFF LO LO pb on, pressure low FIRE VALVE in line: not fully closed cross line: fully closed PUMP NUMBER 1 white: normal 1 amber: N2 below idle ELEC PUMPS ELEC white: supply normal ELEC amber: its power supply has failed OVHT amber: blue or yellow electric pump overheat System label and pressure turn amber below 1 450 PSI
Chapter 5 · Hydraulic Controls, Indications and Failures
13
e-books by eatpl.in · © 2026 · Do not copy or distribute
Now the pumps and valves. The engine pump box shows a green line in line with the flow when its button is on and the pressure is normal. A cross line in amber means the crew has selected the button OFF. And an amber LO in the box means the button is on but the pump pressure is low, which is a real failure. The small number beside the box, one or two, is white, but turns amber when that engine's N two is below idle, telling you the pump has no drive. The fire valve circle has a green in-line bar while it is not fully closed, and an amber cross line once fully closed. Finally, the ELEC legend turns amber if that electric pump's power supply fails, and OVHT appears if the electric pump itself overheats.
HYD page: PTU, RAT, yellow ELEC
PTU, RAT and yellow pump symbols PTU hollow green triangles: AUTO, not transferring PTU amber : PTU pb OFF Solid green arrows towards green : PTU supplying green; towards yellow : supplying yellow RAT white hollow: stowed · green: not stowed · amber: stow pressure applied or pump not available Yellow ELEC triangle: white off · green ON · amber ON with low yellow pressure PTU PTU AUTO, not transferring PTU PTU pb OFF PTU supplying GREEN PTU supplying YELLOW RAT RAT white hollow: stowed RAT green: not stowed RAT amber: stow pressure applied or RAT pump not available Yellow ELEC: white = off · green = on · amber = on, low pressure
Chapter 5 · Hydraulic Controls, Indications and Failures
14
e-books by eatpl.in · © 2026 · Do not copy or distribute
The power transfer unit symbol tells you its state at a glance. With the button at AUTO and nothing being transferred, you see hollow green triangles. If the button is OFF, the symbol is amber. When the unit is working, the arrows become solid green and point in the direction of the power: towards the left when it is supplying green, towards the right when it is supplying yellow. The RAT symbol is white and hollow while stowed, green when the RAT is not stowed, and amber if stowing pressure has been applied or the RAT pump is not available. Finally, the yellow electric pump triangle is white when the pump is off, green when it is on, and amber when it is on but the yellow system still has low pressure.
Memo display
HYD PTU and RAT OUT memos HYD PTU (green): the PTU is runningRAT OUT (green): the RAT is not fully stowedRAT OUT turns amber in flight phases 1 and 2 Typical HYD PTU moment: ground, yellow ELEC pump ON, green coming up memo area HYD PTU the PTU is running RAT OUT RAT not fully stowed RAT OUT same, in flight phases 1 and 2 Green memo: information Amber RAT OUT: needs the crew's attention
Chapter 5 · Hydraulic Controls, Indications and Failures
15
e-books by eatpl.in · © 2026 · Do not copy or distribute
Two hydraulic memos can appear on the engine and warning display. HYD PTU appears in green whenever the power transfer unit is running, so you will often see it on the ground after switching on the yellow electric pump, as green comes up through the unit. RAT OUT appears in green if the ram air turbine is not fully stowed. Its colour changes to amber during flight phases one and two. So the same memo can be a simple green reminder, or an amber one that demands attention, depending on the flight phase. Green memos are information; an amber RAT OUT is the system telling you to look at it before going any further.
Failure example
Blue reservoir overheat: what you see GREEN BLUE YELLOW PTU ENG 1 PUMP RAT MAN ON ELEC PUMP ENG 2 PUMP ELEC PUMP FAULT OFF FAULT OFF FAULT OFF FAULT OFF FAULT ON A U T O A U T O H Y D HYD GREEN 3000 BLUE 0 YELLOW 3000 PSI PSI PTU RAT ELEC 1 2 ELEC OVHT TAT +19 °C SAT +18 °C 23 H 56 GW 60300 KG 1 FAULT on the blue ELEC PUMP pb and an ECAM caution 2 HYD page: OVHT in amber at the blue reservoir 3 Crew selects BLUE ELEC PUMP OFF: blue pressure falls to 0 4 FAULT stays on: the overheat is still there With the pump OFF, blue flight-control actuators are lost; the other systems keep every surface controllable.
Chapter 5 · Hydraulic Controls, Indications and Failures
16
e-books by eatpl.in · © 2026 · Do not copy or distribute
Let us read a real failure, a blue reservoir overheat. First, the amber FAULT light comes on in the blue electric pump button, and the ECAM shows a caution. The HYD page shows OVHT in amber next to the blue reservoir, because the fluid returning to it is too hot. The crew action is to switch the blue electric pump OFF. Blue pressure falls to zero, so the blue label and pressure turn amber and the pump box shows an amber cross line. Now look at the button: it shows OFF, but the FAULT light is still on. That is not a mistake. For an overheat the light stays on for as long as the overheat lasts. Once the fluid cools, it goes out, leaving just OFF.
Failure example
Engine 1 pump failure: the PTU keeps green alive ENG 1 PUMP pb: FAULT (pump low pressure) and ECAM caution HYD page: LO in the engine 1 pump box The PTU sees more than 500 PSI difference and runs : arrows towards green, memo HYD PTU Crew selects the pump OFF: cross line, FAULT goes out Green users keep working, powered from yellow HYD GREEN 2900 BLUE 3000 YELLOW 3000 PSI PSI PTU RAT ELEC 1 2 ELEC TAT +19 °C SAT +18 °C 23 H 56 GW 60300 KG
Chapter 5 · Hydraulic Controls, Indications and Failures
17
e-books by eatpl.in · © 2026 · Do not copy or distribute
Now an engine one pump failure in flight. The engine one pump button shows FAULT, because the pump pressure is low, and the ECAM gives a caution. On the HYD page, the engine one pump box shows an amber LO. Watch the aircraft: the green lines go grey as the pump fails. But green does not stay down, because the difference between green and yellow is now more than five hundred P S I, and the power transfer unit starts all by itself. Yellow now drives green, and the green system restores. The HYD page shows solid green arrows pointing towards green, and the HYD PTU memo appears. When the crew selects the pump OFF, its symbol becomes an amber cross line and the FAULT light goes out. Green users keep working on yellow power.
Normal operation
On the ground: yellow pump and PTU GREEN BLUE YELLOW PTU ENG 1 PUMP RAT MAN ON ELEC PUMP ENG 2 PUMP ELEC PUMP FAULT OFF FAULT OFF FAULT OFF FAULT OFF FAULT ON A U T O A U T O H Y D HYD GREEN 3000 BLUE 0 YELLOW 3000 PSI PSI PTU RAT ELEC LO 1 LO 2 ELEC TAT +19 °C SAT +18 °C 23 H 56 GW 60300 KG 1 Engines stopped: blue at 0 (no engine running, no override) 2 YELLOW ELEC PUMP ON: blue ON light, green triangle on the page 3 PTU runs: solid arrows towards green, HYD PTU memo 4 Engine pumps LO, numbers amber: N2 below idle The same picture at the gate before engine start: yellow from its electric pump, green through the PTU, blue waiting for the first engine.
Chapter 5 · Hydraulic Controls, Indications and Failures
18
e-books by eatpl.in · © 2026 · Do not copy or distribute
Here is a normal ground picture that confuses many students the first time. Both engines are stopped. The crew has switched on the yellow electric pump, so the button shows the blue ON light and the yellow electric pump triangle on the page is green. Yellow is at three thousand P S I. The power transfer unit sees green at zero, starts by itself, and drives green up, so the arrows point towards green and the HYD PTU memo appears. Blue is at zero and amber, because on the ground its pump needs an engine running or the override. And the engine pump boxes show LO with amber numbers, simply because the engines are stopped, so the pumps give no pressure and N two is below idle. Nothing is broken here: this is how the A320 looks before engine start.
Users recap
What each system powers System Heavy users (behind priority valve) Other users Flight controls Green Landing gear · slats and flaps Normal brakes · ENG 1 reverser Rudder, yaw damper 1, THS, L elevator, ailerons, spoilers 1 and 5 Blue Emergency generator · slats — Rudder, both elevators, ailerons, spoilers 3 Yellow Flaps Nose wheel steering · alternate and parking brakes · ENG 2 reverser · cargo doors Rudder, yaw damper 2, THS, R elevator, spoilers 2 and 4
Recap from the previous lesson. Wingtip brakes: slats and right flaps green + blue, left flaps blue + yellow.
Chapter 5 · Hydraulic Controls, Indications and Failures
19
e-books by eatpl.in · © 2026 · Do not copy or distribute
Before we look at failures, here is the users table again in compact form, because every failure question starts from it. Green is the busiest system: landing gear, slats and flaps, normal brakes, the engine one reverser, and a large share of the flight controls, including the rudder, the stabiliser, the left elevator, both ailerons and spoilers one and five. Blue is the lightest: the emergency generator, the slats, and flight controls only, namely the rudder, both elevators, both ailerons and spoilers three. Yellow has the flaps, the nose wheel steering, the alternate and parking brakes, the engine two reverser, the cargo doors, and the rudder, the stabiliser, the right elevator and spoilers two and four. Now let us remove systems one at a time.
Single failures
Losing one system System lost What you lose or what changes Green Normal gear extension (use gravity extension) · normal brakes and autobrake: alternate braking on yellow · slats AND flaps at half speed · ENG 1 reverser · spoilers 1 and 5 · yaw damper 1 Blue Slats at half speed · spoilers 3 · the emergency generator has no drive (it runs on blue) Yellow Nose wheel steering · alternate braking (normal brakes still on green) · flaps at half speed · ENG 2 reverser · spoilers 2 and 4 · yaw damper 2 Any one Rudder, elevators, ailerons and the THS all keep at least one powered actuator or motor
Worked from the users table: if a user has two systems, it survives a single loss; the PCU drives slow to half speed.
Chapter 5 · Hydraulic Controls, Indications and Failures
20
e-books by eatpl.in · © 2026 · Do not copy or distribute
Let us work out single failures straight from the users table. Lose green and you lose the normal gear extension, so the gear comes down by gravity, with the crank isolating it from green. Normal braking and the autobrake go, and braking reverts to the alternate system on yellow. Both the slat and the flap drives lose a motor, so both run at half speed. You also lose the engine one reverser, spoilers one and five and yaw damper one. Lose blue and the slats run at half speed, spoilers three are lost, and the emergency generator has no drive. Lose yellow and you lose nose wheel steering, the alternate brakes, flap speed, the engine two reverser, spoilers two and four and yaw damper two. Every primary surface still keeps power.
Dual failures
Losing two systems Lost Flight control law Main losses Green + blue Alternate law, no protections; roll direct Slats lost (both slat motors) · flaps half speed · left elevator · ailerons go to damping · spoilers 1, 3, 5 · gravity gear extension · alternate braking on yellow Green + yellow Alternate law, reduced protections; roll direct, yaw mechanical THS lost (both motors), trim wheel inoperative · flaps lost, slats half speed · steering · both reversers · spoilers 1, 2, 4, 5 · gravity gear · brakes on the accumulator only, no antiskid Blue + yellow green still drives the rudder, THS, left elevator and ailerons Right elevator · spoilers 2, 3, 4 · slats and flaps half speed · steering · alternate brakes · ENG 2 reverser · emergency generator
Laws from the flight control reconfiguration table; losses derived from the users table and the braking description.
Chapter 5 · Hydraulic Controls, Indications and Failures
21
e-books by eatpl.in · © 2026 · Do not copy or distribute
With two systems gone, the losses add up and the flight control laws change. Green and blue lost: both slat motors are gone, so the slats do not move, the flaps run at half speed, the left elevator and both ailerons lose their actuators, so the ailerons go to damping mode, and the flight controls revert to alternate law without protections. Green and yellow lost: this is the big one for pitch, because both stabiliser motors are gone, so the trim wheel is useless, the flaps are lost, steering and both reversers go, the gear comes down by gravity, and the brakes work only from the accumulator, without antiskid. The law is alternate with reduced protections, and yaw is mechanical. Blue and yellow lost: green still drives the rudder, the stabiliser, the left elevator and the ailerons, but the right elevator, steering and the emergency generator are gone.
Dual failure
Green and yellow lost: blue flies the aircraft Green and yellow routes go grey Only blue remains: rudder, both elevators, ailerons, spoilers 3, slats at half speed No THS: pitch trim figures go amber Gear by gravity ; brakes from the accumulator only Flight controls: alternate law , reduced protections GREEN engine 1 pump YELLOW engine 2 pump BLUE electric pump
Chapter 5 · Hydraulic Controls, Indications and Failures
22
e-books by eatpl.in · © 2026 · Do not copy or distribute
Let us see the green and yellow failure on the aircraft. First the green lines go grey, then the yellow lines go grey too, and only blue is left running down the middle. Blue still powers the rudder, both elevators, both ailerons, spoilers three and the slats, which now move at half speed because only one slat motor works. What is gone? The stabiliser, because both its motors are green and yellow, so the pitch trim figures on the flight control page turn amber and the trim wheel cannot help. The gear has to come down by gravity, the wells shown here, and braking is from the accumulator only. The flight controls revert to alternate law with reduced protections. The aircraft remains controllable, which is the whole point of three systems.
Summary
Hydraulic controls in one page Pump pbs FAULT: reservoir level, overheat or air pressure, pump low pressure (and pump overheat on electric pumps). Out at OFF except overheat.
Blue pump AUTO with AC: runs in flight; on the ground with one engine running or BLUE PUMP OVRD.
PTU pb AUTO armed, OFF closes both valves. FAULT for green or yellow reservoir problems only.
RAT RAT MAN ON any time; auto on loss of AC BUS 1 and 2. White, green or amber symbol; RAT OUT memo.
HYD page Amber below 1 450 PSI. Pump in line, cross line or LO; amber number = N2 below idle.
Failures G+B: no slats, ALTN without protections. G+Y: no THS, no flaps, accumulator brakes, ALTN reduced.
Chapter 5 · Hydraulic Controls, Indications and Failures
23
e-books by eatpl.in · © 2026 · Do not copy or distribute
Let us close the hydraulic chapter. The pump buttons light FAULT for reservoir low level, overheat or low air pressure, and for low pump pressure, and the electric pumps add pump overheat. The light goes out at OFF, except for an overheat. The blue pump at AUTO runs in flight, and on the ground only with an engine running or the override. The power transfer unit button is armed at AUTO, closes both valves at OFF, and lights FAULT only for green or yellow reservoir problems. RAT MAN ON works at any time. On the HYD page, amber below one thousand four hundred and fifty P S I, and learn the pump, valve, PTU and RAT symbols. Finally, know your dual failures: green and blue costs you the slats, green and yellow costs you the stabiliser.