A320 Aircraft Systems · Chapter 4
Hydraulic System: Green, Blue and Yellow Three independent 3 000 PSI systems: the pumps that drive them, the PTU between green and yellow, the RAT, accumulators, valves, reservoirs and the users each system powers.
3 000 PSI · GREEN · BLUE · YELLOW © 2026 eatpl.in. For the personal study of eatpl.in students only. Do not copy or distribute.
e-books by eatpl.in · © 2026 · Do not copy or distribute
Welcome to the hydraulic system of the A320. Hydraulic power moves almost everything heavy on this aircraft: the flight control surfaces, the slats and flaps, the landing gear, the brakes, the nose wheel steering and the thrust reversers. The A320 shares that work between three separate systems, called green, blue and yellow. In this lesson we will meet each system and its pumps, see how the power transfer unit and the ram air turbine back them up, follow the valves and reservoirs that keep them healthy, and finish by mapping every user to its system. The next lesson then covers the panel, the ECAM page and failures.
Hydraulic system
Our route through ATA 29-10 1 Three systems 2 Pumps 3 PTU 4 RAT and hand pump 5 Valves, filters 6 Reservoirs 7 Users Generation Engine pumps, electric pumps, the PTU, the RAT and the hand pump: who makes the pressure.
Protection Accumulators, priority valves, fire and leak measurement valves, filters.
Reservoirs Three separate reservoirs, pressurised by bleed air and closely monitored.
Distribution Which system powers the gear, brakes, steering, reversers and each flight control.
Chapter 4 · Hydraulic System: Green, Blue and Yellow
2
e-books by eatpl.in · © 2026 · Do not copy or distribute
Here is our route through the hydraulic description, chapter twenty nine ten. We start with the big picture: three systems that never mix. Then we look at generation, meaning the pumps on each system, the power transfer unit that links green and yellow, the ram air turbine for blue, and the little hand pump for the cargo doors. Next come the parts that protect and condition the system: accumulators, priority valves, fire shut-off valves, leak measurement valves and filters. Then the reservoirs, how they are kept pressurised and what is measured inside them. Finally we map out distribution, which is the question every interviewer loves: which system powers which user. Keep a picture of green, blue and yellow in your head, because the next lesson builds the cockpit panel and the ECAM page on top of it.
General
Three independent systems Three continuously operating systems: green , blue and yellow Each has its own reservoir Normal pressure 3 000 PSI ; 2 500 PSI when the RAT drives blue Fluid can never be transferred from one system to another Green: engine 1 pump · Yellow: engine 2 pump · Blue: electric pump GREEN engine 1 pump YELLOW engine 2 pump BLUE electric pump
Chapter 4 · Hydraulic System: Green, Blue and Yellow
3
e-books by eatpl.in · © 2026 · Do not copy or distribute
The A320 has three hydraulic systems, coloured green, blue and yellow, and all three run continuously in flight. Each has its own reservoir. Watch the aircraft: the green system starts at the pump on engine one, the left engine. The blue system has no engine pump at all; an electric pump drives it. And the yellow system starts at the pump on engine two, the right engine. Normal pressure is three thousand P S I, or two thousand five hundred P S I when the ram air turbine is the only thing driving blue. The key design rule is separation: hydraulic fluid can never pass from one system to another. So a leak that empties one reservoir cannot drain the other two. Hold on to that idea, because the power transfer unit we meet later moves power between systems, never fluid.
Generation
The generation schematic at a glance to green users to blue users to yellow users GREEN RESERVOIR ENG 1 PUMP M ENG 1 FIRE SHUT-OFF VALVE BLUE RESERVOIR M ELEC PUMP RAT PUMP YELLOW RESERVOIR ENG 2 PUMP M ELEC PUMP M ENG 2 FIRE SHUT-OFF VALVE CARGO DOORS HAND PUMP ACCUMULATOR LEAK MEASUREMENT VALVE PTU Read each system from its reservoir upward: suction, pump(s), accumulator, leak measurement valve, then the users.
Chapter 4 · Hydraulic System: Green, Blue and Yellow
4
e-books by eatpl.in · © 2026 · Do not copy or distribute
This is our own drawing of the whole generation side, and it is worth learning to read it bottom up. Each system starts at its reservoir at the bottom. On green, fluid passes the engine one fire shut-off valve and reaches the engine one pump. Blue has its electric pump with the ram air turbine pump in parallel. Yellow has the engine two pump, its fire shut-off valve, and an electric pump in parallel, plus a separate hand pump branch that only serves the cargo doors. Higher up, every system has an accumulator, and just before the users a leak measurement valve. Across the top runs the power transfer unit, linking green and yellow and hopping over blue without touching it. Over the next slides we will zoom into each of these pieces in turn.
Generation: green
Green: one engine-driven pump One pump, driven by engine 1 , pressurises green No electric pump on green The ENG 1 FIRE shut-off valve sits upstream of the pump Back-up: the PTU can pressurise green from yellow On the ground with engines stopped, green gets pressure only through the PTU to green users to blue users to yellow users GREEN RESERVOIR ENG 1 PUMP M ENG 1 FIRE SHUT-OFF VALVE BLUE RESERVOIR M ELEC PUMP RAT PUMP YELLOW RESERVOIR ENG 2 PUMP M ELEC PUMP M ENG 2 FIRE SHUT-OFF VALVE CARGO DOORS HAND PUMP ACCUMULATOR LEAK MEASUREMENT VALVE PTU ONE pump only driven by engine 1 backed up by the PTU
Chapter 4 · Hydraulic System: Green, Blue and Yellow
5
e-books by eatpl.in · © 2026 · Do not copy or distribute
Let us start with green. A single pump, driven by engine one, pressurises the whole green system. There is no electric pump on green. So ask yourself the classic question: with both engines stopped on the stand, how do you get green pressure? The answer is through the power transfer unit, by first pressurising yellow with its electric pump. We will come back to that. Notice also the engine one fire shut-off valve in the suction line, upstream of the pump. If you push the engine one fire pushbutton, that valve closes and the engine pump can no longer be supplied. And if the engine one pump is lost in flight, the power transfer unit is again the back-up, because yellow can drive green through it.
Generation: blue
Blue: electric pump, RAT in emergency An electric pump pressurises blue In an emergency a pump driven by the ram air turbine (RAT) takes over Blue has no engine pump and no PTU connection On the RAT, pressure is 2 500 PSI The blue electric pump and the engine pumps have case drain filters (wear check) to green users to blue users to yellow users GREEN RESERVOIR ENG 1 PUMP M ENG 1 FIRE SHUT-OFF VALVE BLUE RESERVOIR M ELEC PUMP RAT PUMP YELLOW RESERVOIR ENG 2 PUMP M ELEC PUMP M ENG 2 FIRE SHUT-OFF VALVE CARGO DOORS HAND PUMP ACCUMULATOR LEAK MEASUREMENT VALVE PTU NO engine pump electric pump RAT: emergency
Chapter 4 · Hydraulic System: Green, Blue and Yellow
6
e-books by eatpl.in · © 2026 · Do not copy or distribute
Blue is the odd one out. It has no engine-driven pump, and it is not connected to the power transfer unit. In normal operation an electric pump keeps blue at three thousand P S I. In an emergency, when electrical power is lost or both engines have failed, a pump turned by the ram air turbine takes over, and blue then runs at two thousand five hundred P S I. That makes blue the system that survives a total loss of engines, which is exactly why it also drives the emergency generator, as we will see. A small practical detail: the blue electric pump, like the engine pumps, has a case drain filter, so maintenance can inspect it for metal particles and spot a pump that is wearing out.
Generation: yellow
Yellow: engine pump, electric pump and hand pump Normal source: a pump driven by engine 2 An electric pump also pressurises yellow, so it can be used on the ground with engines stopped A hand pump works the cargo doors when no electrical power is available The ENG 2 FIRE shut-off valve sits upstream of the engine pump Yellow is the ground-service system: it can feed green through the PTU to green users to blue users to yellow users GREEN RESERVOIR ENG 1 PUMP M ENG 1 FIRE SHUT-OFF VALVE BLUE RESERVOIR M ELEC PUMP RAT PUMP YELLOW RESERVOIR ENG 2 PUMP M ELEC PUMP M ENG 2 FIRE SHUT-OFF VALVE CARGO DOORS HAND PUMP ACCUMULATOR LEAK MEASUREMENT VALVE PTU
Chapter 4 · Hydraulic System: Green, Blue and Yellow
7
e-books by eatpl.in · © 2026 · Do not copy or distribute
Yellow has the most pumps. Its normal source is the pump on engine two. It also has an electric pump, and that is what lets the crew or the engineers use yellow hydraulics on the ground with both engines stopped, for example to pressurise the brakes or to move the cargo doors. Then there is a hand pump, which is purely for operating the cargo doors when there is no electrical power at all. As on green, the engine two fire shut-off valve sits upstream of the engine pump, and the engine two fire pushbutton closes it. Because yellow has an electric pump and green does not, yellow is the natural ground-service system, and through the power transfer unit it can bring green to life too.
Generation
Who pressurises what: a summary System Normal source Other sources On the ground, engines stopped Green Engine 1 pump PTU (from yellow) PTU, once yellow is pressurised Blue Electric pump RAT pump (emergency, 2 500 PSI) Electric pump, see the next lesson for its logic Yellow Engine 2 pump Electric pump · PTU (from green) · hand pump (cargo doors only) Yellow electric pump All three 3 000 PSI Own reservoir each No fluid transfer between systems
Interview favourite: green has one pump, blue has no engine pump, yellow has four ways to be pressurised.
Chapter 4 · Hydraulic System: Green, Blue and Yellow
8
e-books by eatpl.in · © 2026 · Do not copy or distribute
Let us pull the pumps together in one table, because examiners love to ask it in different ways. Green has only the engine one pump, and its back-up is the power transfer unit taking power from yellow. Blue has the electric pump, and the ram air turbine pump in an emergency, at two thousand five hundred P S I. Yellow has the engine two pump, the electric pump, the power transfer unit taking power from green, and the hand pump, although the hand pump only serves the cargo doors. On the ground with the engines stopped, yellow comes from its electric pump, and green from the power transfer unit once yellow is up. The blue electric pump has its own ground logic, which we cover in the next lesson.
Power transfer unit
The PTU: power without fluid A bidirectional PTU links green and yellow A hydraulic motor on one side turns a pump on the other, on one shaft It runs automatically when the green–yellow difference is more than 500 PSI Works in either direction : yellow can drive green, green can drive yellow It moves power , never fluid GREEN YELLOW PTU one shaft, two units pump motor Runs by itself when | green − yellow | > 500 PSI works in either direction bidirectional: power, never fluid
Chapter 4 · Hydraulic System: Green, Blue and Yellow
9
e-books by eatpl.in · © 2026 · Do not copy or distribute
The power transfer unit, or P T U, is the clever link between green and yellow. It is two hydraulic units on one shaft. In this scene both systems start at three thousand P S I and the unit sits still. Now the green engine pump fails, and green pressure drops. As soon as the difference between the two systems is more than five hundred P S I, the unit wakes up on its own. Yellow pressure turns the yellow side as a motor, the shaft spins, and the green side works as a pump, which restores green pressure. Each side keeps its own fluid, so power crosses over but fluid never does. And it is bidirectional: if yellow were the weak side, green would drive yellow in exactly the same way.
PTU worked examples
Will the PTU run? Check the 500 PSI rule Situation Green Yellow Difference PTU Normal flight, both engine pumps 3 000 3 000 0 Idle (armed) Engine 1 pump lost falls to 2 400 3 000 600 Runs: yellow drives green Small fluctuation 2 750 3 000 250 Idle Engine 2 pump lost 3 000 falls to 2 300 700 Runs: green drives yellow Ground, engines off, yellow elec pump ON 0 3 000 3 000 Runs: yellow drives green Ground, engines off, nothing running 0 0 0 Nothing to transfer
The pressures in rows 2 and 4 are example numbers to practise the rule; the trigger is the difference, more than 500 PSI.
Chapter 4 · Hydraulic System: Green, Blue and Yellow
10
e-books by eatpl.in · © 2026 · Do not copy or distribute
Let us practise the five hundred P S I rule with a few numbers. In normal flight both systems are at three thousand, the difference is zero, and the unit is simply armed and idle. If the engine one pump fails and green falls to, say, two thousand four hundred, the difference is six hundred, which is more than five hundred, so the unit runs and yellow drives green. A small wobble to two thousand seven hundred and fifty gives only two hundred and fifty, so nothing happens. Lose the engine two pump instead and green drives yellow. On the ground with the yellow electric pump on, the difference is the full three thousand and green comes up. But with nothing running at all there is no power on either side to transfer.
PTU on the ground
Using the PTU with the engines stopped Yellow electric pump ON gives yellow pressure The PTU then pressurises green : that is how green is used on the ground PTU pb at AUTO : armed, both electrohydraulic valves open Inhibited during the first engine start Automatically tested during the second engine start Engines stopped YELLOW ELEC PUMP Yellow 3 000 PSI PTU runs Green pressurised Yellow users Blue: needs AC power and an engine running or BLUE PUMP OVRD difference > 500 PSI
Chapter 4 · Hydraulic System: Green, Blue and Yellow
11
e-books by eatpl.in · © 2026 · Do not copy or distribute
Here is the practical use of the power transfer unit on the ground. With both engines stopped, switch on the yellow electric pump. Yellow comes up to pressure, the difference with green is far more than five hundred P S I, and the unit drives green up as well. That is the reference reason for having it: it lets the green system be pressurised on the ground with the engines stopped. Two details about engine start are worth memorising. The unit is inhibited during the first engine start, and it is automatically tested during the second engine start. And remember that with the pushbutton at AUTO the unit is armed, with both its green and yellow electrohydraulic valves open. The pushbutton itself is covered in the next lesson.
Ram air turbine
The RAT: blue when everything else is gone A drop-out RAT coupled to a hydraulic pump Keeps blue working if electrical power is lost or both engines fail Deploys automatically if AC BUS 1 and AC BUS 2 are both lost Can be deployed manually from the overhead panel at any time Can be stowed only on the ground Blue pressure on the RAT: 2 500 PSI AC BUS 1 and AC BUS 2 lost or RAT MAN ON pressed RAT drops out Blue system 2 500 PSI Hydraulic motor → EMER GEN AC ESS BUS and DC ESS BUS Stowing the RAT: on the ground only
Chapter 4 · Hydraulic System: Green, Blue and Yellow
12
e-books by eatpl.in · © 2026 · Do not copy or distribute
The ram air turbine, the RAT, is a small propeller on a strut that normally sits stowed inside the aircraft. Watch it drop out into the airflow. The airflow turns the turbine, the turbine turns its pump, and that pump pressurises the blue system, here climbing to two thousand five hundred P S I. Its purpose is to keep blue working if electrical power is lost or if both engines fail. It deploys automatically when AC bus one and AC bus two are both lost, and the crew can also deploy it manually from the overhead panel at any time. One more point that catches people out: once it is out, it can be stowed only when the aircraft is on the ground. You cannot put it away again in flight.
RAT and the emergency generator
Why blue matters to the electrics RAT out: the RAT pump pressurises blue Blue drives the emergency generator through a hydraulic motor The emergency generator supplies the AC ESS and DC ESS buses So the RAT gives back both hydraulic power and essential electrical power The emergency generator sits behind blue's priority valve AC BUS 1 and AC BUS 2 lost or RAT MAN ON pressed RAT drops out Blue system 2 500 PSI Hydraulic motor → EMER GEN AC ESS BUS and DC ESS BUS Stowing the RAT: on the ground only
Chapter 4 · Hydraulic System: Green, Blue and Yellow
13
e-books by eatpl.in · © 2026 · Do not copy or distribute
Now let us connect the RAT to the electrical system, because this chain is a favourite in interviews. When AC bus one and AC bus two are both lost, the RAT drops out and pressurises blue. Blue then drives the emergency generator by means of a hydraulic motor, and that generator supplies the AC essential and DC essential buses. So the ram air turbine gives the crew two things at once: blue hydraulic power for the flight controls, and essential electrical power for the instruments and computers that matter most. In the distribution drawing you will also find the emergency generator listed on blue, behind its priority valve, alongside the slats. If you understand this chain, the electrical emergency configuration in the electrical chapter will make far more sense.
Yellow ground functions
Cargo doors: electric pump and hand pump The cargo doors are worked by the yellow system Moving the cargo door selector valve lever to OPEN or CLOSE starts the yellow electric pump automatically Other yellow functions are then inhibited , except alternate braking and the engine 2 reverser With no electrical power, a hand pump works the doors CARGO DOORS SV door selector valve lever: OPEN / CLOSE M YELLOW ELEC PUMP starts by itself when the lever is moved HAND PUMP no electrical power While the pump runs for the doors, other yellow users are inhibited except alternate braking and the engine 2 reverser
Chapter 4 · Hydraulic System: Green, Blue and Yellow
14
e-books by eatpl.in · © 2026 · Do not copy or distribute
The cargo doors open and close hydraulically, and they use the yellow system. On the door service panel there is a selector valve lever. When someone sets that lever to open or close, the yellow electric pump comes on automatically, even though its cockpit switch is off. While the pump is running for the doors, the other yellow functions are inhibited, with two exceptions: alternate braking and the engine two thrust reverser. That protects the ground crew, because nothing else on yellow moves while they work the doors. And if there is no electrical power at all, a hand pump on the yellow system can open and close the doors. Remember: the hand pump is only for the cargo doors. It is not a back-up for flying the aircraft.
Accumulators
Accumulators: smoothing the demand There is one accumulator in each system A gas charge behind a piston stores fluid under pressure It covers transient demands during normal operation So the system pressure stays nearly constant when a big user suddenly moves The pump then refills it gas charge free piston fluid from pump to users covers transient demands, keeps pressure steady
Chapter 4 · Hydraulic System: Green, Blue and Yellow
15
e-books by eatpl.in · © 2026 · Do not copy or distribute
Each of the three systems has an accumulator. Inside, a gas charge pushes on a free piston, and below the piston is hydraulic fluid at system pressure. Think of the gas as a spring. In normal operation, when a user suddenly demands a lot of flow, for example a large control surface moving quickly, the pump cannot respond instantly. So the accumulator gives up some of its stored fluid, as you see here, and the system pressure stays almost constant. As soon as the demand has passed, the pump refills it and the piston moves back up. That is the reference job of the accumulators: they help to maintain a constant pressure by covering transient demands. Do not confuse them with the separate brake accumulator, which belongs to the braking system.
Priority valves
Priority valves: flight controls first If system pressure gets low , priority valves cut off heavy-load users What is left goes to the flight controls Green: landing gear , slats and flaps sit behind its priority valve Blue: emergency generator and slats Yellow: flaps Flight controls Heavy users PRIORITY VALVE: shut low pressure: heavy users cut off
Chapter 4 · Hydraulic System: Green, Blue and Yellow
16
e-books by eatpl.in · © 2026 · Do not copy or distribute
Priority valves decide who gets the fluid when there is not enough to go round. If the pressure in a system gets low, the priority valve cuts off hydraulic power to the heavy-load users, so that what pressure remains goes to the flight controls. In this scene the system pressure falls, the valve shuts, and the heavy-user branch stops while the flight controls keep flowing. On the A320 distribution drawing, green has the landing gear and the slats and flaps behind its priority valve. Blue has the emergency generator and the slats. Yellow has the flaps. The logic is simple: you can live with slow flaps or a gear problem for a while, but you always need to be able to control the aircraft.
Fire shut-off valves
Fire shut-off valves on green and yellow Green and yellow each have a fire shut-off valve It sits in the line upstream of the engine-driven pump The crew closes it by pushing the ENG 1 (2) FIRE pushbutton Blue has none: it has no engine pump On the HYD page, a closed valve is an amber cross line ENG 1 PUMP downstream M FIRE SHUT-OFF VALVE: closed GREEN RESERVOIR ENG 1 FIRE ENG 1 FIRE pb push Valve sits UPSTREAM of the engine pump, in its supply line green: ENG 1 FIRE pb yellow: ENG 2 FIRE pb blue: none to users
Chapter 4 · Hydraulic System: Green, Blue and Yellow
17
e-books by eatpl.in · © 2026 · Do not copy or distribute
Green and yellow each have a fire shut-off valve, in the line upstream of their engine-driven pump. In other words it sits between the reservoir and the pump, in the supply to the engine. If there is an engine fire, the crew pushes that engine's fire pushbutton, and among the many things it does, it closes the hydraulic fire shut-off valve, so that no more hydraulic fluid is fed into the fire zone. Engine one fire closes the green valve, and engine two fire closes the yellow valve. Blue has no fire shut-off valve, simply because it has no engine pump. On the ECAM hydraulic page you will see the valve as a small circle: a green in-line bar while it is open, an amber cross line when it is fully closed.
Leak measurement valves
Leak measurement valves: a maintenance tool Each system has a leak measurement valve upstream of the primary flight controls Closed from the LEAK MEASUREMENT VALVES pushbuttons (B, G, Y) on the maintenance panel OFF: the valve closes and shuts off supply to the primary flight controls Used to measure the leakage in each circuit The switches are guarded HYD BLUE PUMP OVRD LEAK MEASUREMENT VALVES B OFF G OFF Y OFF ON maintenance panel (guarded switches) to the PRIMARY FLIGHT CONTROLS switch OFF: valve closes, flight controls isolated
Chapter 4 · Hydraulic System: Green, Blue and Yellow
18
e-books by eatpl.in · © 2026 · Do not copy or distribute
Every system has a leak measurement valve just upstream of the primary flight controls. It is a maintenance tool. Engineers want to know how much internal leakage there is in each circuit, so they close the valve to isolate the flight control part of the system and measure the leakage in the rest. The valves are worked from the maintenance panel, which carries three guarded pushbuttons labelled B, G and Y under the heading leak measurement valves. Selecting one OFF closes its electrohydraulic valve and shuts off the hydraulic supply to the primary flight controls on that system; selecting it back on reopens the valve. Obviously that is not something you do in flight. The same panel also has the BLUE PUMP OVRD switch, which we will use in the next lesson.
Filters
Keeping the fluid clean Dirty fluid wears pumps and jams valves, so filters sit at every important point.
HP filters On each system, on the reservoir filling system and on the normal braking system.
Return line filters On each return line, cleaning the fluid on its way back to the reservoir.
Case drain filters On the engine pumps and the blue electric pump. Metal particles found here show pump wear.
Chapter 4 · Hydraulic System: Green, Blue and Yellow
19
e-books by eatpl.in · © 2026 · Do not copy or distribute
Clean fluid matters enormously in a three thousand P S I system, because tiny particles wear pumps and can jam valves and servos. So the A320 has filters at every key point. High pressure filters sit on each system, on the reservoir filling system and on the normal braking system. Return line filters clean the fluid on each return line on its way back to the reservoir. And case drain filters sit on the engine-driven pumps and on the blue electric pump. Those case drain filters have a clever second job. Maintenance staff inspect them for metallic particles, which tells them a pump is starting to wear before it fails. As a pilot you will not see the filters, but you should know why they are there.
Reservoirs
Reservoir pressurisation Normally HP bleed air from engine 1 pressurises all three reservoirs automatically If that bleed pressure is too low , air is taken from the crossbleed duct Purpose: keep the pump inlets pressurised so the pumps do not cavitate Low air pressure triggers a LO AIR PRESS indication and an ECAM caution GREEN BLUE YELLOW ENG 1 HP bleed pressure-reducing valve Crossbleed duct if bleed too low aim: no pump cavitation
Chapter 4 · Hydraulic System: Green, Blue and Yellow
20
e-books by eatpl.in · © 2026 · Do not copy or distribute
Hydraulic pumps hate low inlet pressure, because the fluid can boil into vapour bubbles, which is called cavitation, and that damages the pump very quickly. So the A320 pressurises its three reservoirs with air. Normally high pressure bleed air from engine one does the job automatically, through a pressure reducing valve. Watch the bleed air reach all three reservoirs. If the engine one bleed pressure is too low, the system takes air from the crossbleed duct instead. Either way, the aim is a reservoir pressure high enough to stop the pumps cavitating. If the air pressure in a reservoir does fall below normal, you get a low air pressure indication on the HYD page and an ECAM caution, which we will see in the next lesson.
Reservoirs
Reservoir sizes and the low-level warning Green reservoir 14.5 L , blue 6.5 L , yellow 12.5 L (total scale) Low-level warning at 3.5 L (green and yellow) and 2.4 L (blue) Normal filling band at the top: 2.6 L (green, yellow), 1.6 L (blue) Below the warning level the HYD page quantity turns amber Blue is the smallest: it has the fewest users Reservoir volume (litres) 0 5 10 15 14.5 L low 3.5 GREEN 6.5 L low 2.4 BLUE 12.5 L low 3.5 YELLOW normal filling band (top) low-level warning
Chapter 4 · Hydraulic System: Green, Blue and Yellow
21
e-books by eatpl.in · © 2026 · Do not copy or distribute
The three reservoirs are not the same size, and the numbers make sense once you know the users. Green, with the landing gear and lots of flight controls, has the biggest scale at fourteen point five litres. Yellow is twelve point five litres. Blue, with no gear, brakes or reversers, is only six point five litres. The low level warning comes at three point five litres on green and yellow, and two point four litres on blue. At the top of each scale is the normal filling band, two point six litres on green and yellow and one point six on blue. On the ECAM HYD page the reservoir quantity is green, and it turns amber once the level falls below the warning level. A falling quantity is your first clue to a leak.
Indications
What each system measures System pressure and system low pressure Engine pump low pressure (green and yellow)Reservoir low air pressure , low level and fluid temperature (overheat) Signals go to the ECAM (caution and HYD page) Reservoir and pump faults also light the FAULT light on the pump pushbutton RESERVOIR SYS LO PR system pressure low SYS PRESS pressure readout ENG PUMP LO PR pump pressure low LO AIR PR reservoir air pressure LO LVL · FLUID TEMP quantity and overheat ECAM caution HYD page FAULT pb light
Chapter 4 · Hydraulic System: Green, Blue and Yellow
22
e-books by eatpl.in · © 2026 · Do not copy or distribute
Each system is watched by a set of sensors, and it is worth knowing what they are because every one has a cockpit indication. Near the users there is a system pressure transmitter and a system low pressure switch. On the engine pump there is a pump low pressure switch. At the reservoir there are three more: low air pressure, low fluid level, and fluid temperature, which gives the overheat warning. All of these go to the ECAM, which shows a caution and the HYD system page. Several of them also light the amber FAULT light in the pump pushbutton on the overhead panel, so the crew can see at a glance which system is unhappy. We will decode every one of those lights and symbols in the next lesson.
Distribution
Which system powers which user GREEN PRESSURE behind the priority valve Landing gear Slats and flaps (PCU) PRIORITY VALVE other users Normal brakes Engine 1 reverser flight controls Rudder yaw damper 1 Stabiliser (THS) Left elevator L and R ailerons Spoilers 1 and 5 Slat WTBs R flap WTB leak measurement valve BLUE PRESSURE behind the priority valve Emergency generator Slats (PCU) PRIORITY VALVE flight controls Rudder L and R elevators L and R ailerons Spoilers 3 Slat and flap WTBs leak measurement valve YELLOW PRESSURE behind the priority valve Flaps (PCU) PRIORITY VALVE other users Nose wheel steering Alternate and parking brakes Engine 2 reverser Cargo doors flight controls Rudder yaw damper 2 Stabiliser (THS) Right elevator Spoilers 2 and 4 L flap WTB leak measurement valve The rudder has all three systems; the stabiliser has green and yellow; each elevator and aileron has two.
Chapter 4 · Hydraulic System: Green, Blue and Yellow
23
e-books by eatpl.in · © 2026 · Do not copy or distribute
Here is the distribution of hydraulic power, drawn our way. For each system, the first group sits behind the priority valve: on green, the landing gear and the slats and flaps; on blue, the emergency generator and the slats; on yellow, the flaps. Next come other users. Green feeds the normal brakes and the engine one reverser. Yellow feeds the nose wheel steering, the alternate and parking brakes, the engine two reverser and the cargo doors. Blue has none of those. On the right of each column are the flight controls, supplied through the leak measurement valve. Notice the pattern of redundancy: the rudder has all three systems, the stabiliser has green and yellow, and each aileron and elevator has two different systems. We will now look at these users in more detail.
Users: gear, brakes, steering
Gear, brakes and steering Green actuates all landing gear and doorsNormal brakes: green ; alternate brakes: yellow , backed up by the brake accumulator Parking brake: yellow or the brake accumulator Nose wheel steering: yellow Reversers: engine 1 green , engine 2 yellow Above 260 kt a safety valve cuts the gear supply GREEN engine 1 pump YELLOW engine 2 pump BLUE electric pump
Chapter 4 · Hydraulic System: Green, Blue and Yellow
24
e-books by eatpl.in · © 2026 · Do not copy or distribute
Now the ground users. The green system actuates all the landing gear and the gear doors. Watch the main gear retract into its bays, the doors open and close, and the nose gear fold forward, all on green. When the aircraft is faster than two hundred and sixty knots, a safety valve automatically cuts hydraulic supply to the gear, and below that the supply stays cut off while the gear lever is up. Brakes are split. Normal braking uses green. Alternate braking uses yellow, backed up by the brake accumulator, and the parking brake uses yellow or that accumulator. Nose wheel steering is yellow. And the thrust reversers follow the engine pumps: engine one reverser on green, engine two reverser on yellow.
Users: flight controls
Flight controls by system Surface Green Blue Yellow Rudder ● ● ● Yaw damper 1 2 Stabiliser (THS) ● ● Left elevator / right elevator left left and right right Ailerons (left and right) ● ● Spoilers (each wing) 1 and 5 3 2 and 4 Slats / flaps (PCU motors) slats and flaps slats flaps
Every primary control has at least two systems. Losing any one system never leaves a surface without power.
Chapter 4 · Hydraulic System: Green, Blue and Yellow
25
e-books by eatpl.in · © 2026 · Do not copy or distribute
Here are the flight controls system by system, and this table is worth learning by heart. The rudder has all three systems. Yaw damper one is green and yaw damper two is yellow. The trimmable horizontal stabiliser is driven by green and yellow. Each elevator has two systems: the left elevator green and blue, the right elevator blue and yellow. Both ailerons are green and blue. The spoilers are spread out on each wing: number one and number five on green, number three on blue, and numbers two and four on yellow. Finally, the slat drive uses green and blue motors and the flap drive uses green and yellow. Look at the pattern: no single hydraulic failure leaves any primary surface without power.
Users: slats, flaps and trim
Slats, flaps and the stabiliser Each power control unit has two hydraulic motors and a differential gearbox Slats: green + blue · Flaps: green + yellow If one system is lost, that drive runs at half speed THS: a screwjack driven by two hydraulic motors (green and yellow) Mechanical trim wheel works if green or yellow is available Slat and flap power control units SLATS G B differential gearbox FLAPS G Y differential gearbox One hydraulic system lost: that slat or flap drive runs at HALF SPEED Stabiliser (THS) screwjack: two hydraulic motors G Y Mechanical trim wheel works if green OR yellow is available WTBs: slats and R flaps G+B · L flaps B+Y
Chapter 4 · Hydraulic System: Green, Blue and Yellow
26
e-books by eatpl.in · © 2026 · Do not copy or distribute
The slats and flaps each have a power control unit with two independent hydraulic motors joined by a differential gearbox. The slat unit uses green and blue, and the flap unit uses green and yellow. Because the two motors add their speeds, losing one hydraulic system does not stop the surfaces. They still move, but at half speed. That is why a green failure gives you slow slats and slow flaps, since green feeds both units. The wingtip brakes, which lock the surfaces after a runaway or asymmetry, use green and blue for the slats and the right flaps, and blue and yellow for the left flaps. Finally, the stabiliser is moved by a screwjack driven by two hydraulic motors, and the mechanical trim wheel works whenever green or yellow is available.
Summary
Hydraulic generation and distribution in one page Three systems Green, blue, yellow; own reservoirs; 3 000 PSI (2 500 on the RAT); no fluid transfer.
Pumps Green: ENG 1. Blue: electric, RAT in emergency. Yellow: ENG 2, electric, hand pump for cargo doors.
PTU Green and yellow, either way, by itself above 500 PSI difference. Inhibited on 1st engine start, tested on 2nd.
RAT Auto on loss of AC BUS 1 and 2, manual any time, stow on ground only; drives the EMER GEN via blue.
Valves Accumulators smooth demand; priority valves protect flight controls; fire valves on G and Y; leak valves for maintenance.
Users Gear green; NWS yellow; brakes green, then yellow and accumulator; rudder all three; THS G and Y.
Chapter 4 · Hydraulic System: Green, Blue and Yellow
27
e-books by eatpl.in · © 2026 · Do not copy or distribute
Let us wrap up. There are three continuously operating systems, green, blue and yellow, each with its own reservoir, at three thousand P S I, or two thousand five hundred on the RAT, and fluid never passes between them. Green has the engine one pump, blue an electric pump with the RAT as emergency back-up, and yellow the engine two pump, an electric pump and a hand pump for the cargo doors. The power transfer unit links green and yellow in either direction, all by itself above a five hundred P S I difference. Accumulators smooth demand, priority valves protect the flight controls, fire valves isolate the engine pumps, and leak valves serve maintenance. And remember the users: gear on green, steering on yellow, rudder on all three. Next lesson: the cockpit controls.