A320 Aircraft Systems · Chapter 27
Oxygen Three oxygen systems for three jobs: the cockpit masks for smoke and depressurisation, the passenger masks for depressurisation, and portable oxygen and smoke hoods for the crew.
© 2026 eatpl.in. For the personal study of eatpl.in students only. Do not copy or distribute.
e-books by eatpl.in · © 2026 · Do not copy or distribute
Welcome to the oxygen lesson, chapter thirty five. Oxygen is the system you hope never to use, and must be able to use without thinking. The A320 has three oxygen systems: a fixed system for the cockpit, a fixed system for the passengers and cabin crew, and portable equipment, including the smoke hood. We will learn how the crew masks are supplied and how to don them in seconds, what the N, one hundred per cent and emergency settings do, how to read the oxygen pressure on the ECAM, when and how the passenger masks drop, and how to use the protective breathing equipment. Interviewers love this chapter, so let us get the numbers right.
Lesson roadmap
Oxygen in four parts ATA 35 . Three systems, each with its own job. Learn the numbers: they are favourite exam and interview questions.
1 · Cockpit fixed oxygen Cylinder, regulator, safety port, CREW SUPPLY valve, masks and stowage boxes.
2 · Using the crew mask Donning, N / 100% / EMERGENCY , ECAM DOOR/OXY , test and stowage.
3 · Passenger oxygen Chemical generators, 14 000 ft release, MASK MAN ON , SYS ON, OXY PAX ON .
4 · Portable oxygen Protective breathing equipment: hood, regeneration, 15 min , serviceability.
Chapter 27 · Oxygen
2
e-books by eatpl.in · © 2026 · Do not copy or distribute
Here is our route through the oxygen chapter. Part one is the cockpit fixed system: the cylinder, the regulator, the overpressure safety, the CREW SUPPLY valve and the masks. Part two is about using the crew mask: how to don it, what the N, one hundred per cent and emergency settings do, how to read the oxygen pressure on the ECAM, and how to test and restow the mask. Part three is the passenger system with its chemical generators, the altitude at which the masks drop, the MASK MAN ON button and the memo. Part four is the portable equipment, especially the protective breathing equipment, the smoke hood. Keep a notebook handy for the numbers.
Overview
Three oxygen systems Cockpit fixed system High-pressure cylinder in the left lower fuselage Regulator, supply valve, masks at every cockpit seat Used for Depressurisation, smoke, noxious gases Cabin fixed system Chemical generators in containers above the seats, lavatories, galleys and cabin crew stations Used for Depressurisation Portable oxygen Bottles in cockpit and cabin; protective breathing equipment (smoke hood) for the crew Used for Crew protection during emergencies; first aid
Cockpit fixed : depressurisation, smoke, fumes · Cabin fixed : depressurisation · Portable : crew protection and first aid
Chapter 27 · Oxygen
3
e-books by eatpl.in · © 2026 · Do not copy or distribute
The A320 has three separate oxygen systems. The cockpit fixed system takes oxygen from a high pressure cylinder in the lower fuselage and pipes it up to a mask at every seat in the cockpit. It protects the flight crew in a depressurisation, and also against smoke and noxious gases, which is why it is a gas cylinder you can draw from at any time. The cabin fixed system uses chemical generators in mask containers above the seat rows and elsewhere in the cabin. It is only for depressurisation. Finally, portable oxygen bottles and the smoke hood, or protective breathing equipment, are carried in the cockpit and cabin, to protect the crew during an emergency on board and for first aid.
Part 1 · Cockpit fixed oxygen
The parts of the crew system One high-pressure cylinder in the left lower fuselage A pressure regulator on the cylinder delivers a usable pressure Two overpressure safety systems vent overboard through a safety port A supply solenoid valve lets the crew shut off the distribution Three (or four) full-face quick-donning masks , one at each seatCockpit fixed oxygen: the parts 1 High-pressure cylinder left-hand lower fuselage 2 Pressure regulator on the cylinder: delivers user pressure 3 Two overpressure safety systems vent overboard through a safety port 4 Supply solenoid valve crew can shut off the distribution 5 Three (or four) full-face masks quick-donning, one at each seat Used for depressurisation, smoke and noxious gases
Chapter 27 · Oxygen
4
e-books by eatpl.in · © 2026 · Do not copy or distribute
In its basic form, the cockpit fixed system has five kinds of parts. A single high pressure cylinder sits in the left hand lower fuselage. Connected directly to it is a pressure regulator, which reduces the cylinder pressure to a pressure suitable for the masks. If that pressure ever becomes too high, two overpressure safety systems vent the oxygen overboard through a safety port in the skin. Downstream, a supply solenoid valve lets the crew shut off the whole distribution system. And at the end are three full-face quick-donning masks, or four if the fourth occupant seat is fitted, each stowed in a box right beside its seat so it can be reached in seconds.
Part 1 · Cockpit fixed oxygen
From the cylinder to the masks O2 CYLINDER direct reading pressure gauge manual isolation valve PRESSURE REGULATOR high to low pressure safety port / overboard discharge indicator overpressure safety P supply solenoid valve (CREW SUPPLY pb) MANIFOLD mask stowage box CAPT mask stowage box F/O mask stowage box 3rd OCC + 4th occupant (if installed) CKPT OXY 1850 PSI ECAM DOOR/OXY page High pressure Low pressure High pressure: cylinder → regulator · Low pressure: solenoid valve (CREW SUPPLY) → manifold → masks · Pressure sent to the ECAM
Chapter 27 · Oxygen
5
e-books by eatpl.in · © 2026 · Do not copy or distribute
Let us follow the oxygen. It starts in the high pressure cylinder, whose contents you can read on a direct reading gauge on the cylinder itself, and which has a manual isolation valve. The regulator on the cylinder reduces the pressure. Now the gas is at low pressure and reaches the supply solenoid valve, which the crew controls with the CREW SUPPLY pushbutton. With the valve open, oxygen flows to a distribution manifold and on to the mask stowage boxes, one for each seat. Every time you breathe, the system uses a little, and the cylinder pressure falls. A transducer sends that pressure to the ECAM. If the low pressure part is ever overpressurised, the excess is vented overboard through the safety port.
Part 1 · A variant
Two cylinders on some aircraft Some aircraft have two sub-systems Sub-system 1: captain and third occupant Sub-system 2: first officer and fourth occupant Two cylinders, two regulators, four overpressure safety systems, two solenoid valves Overpressure goes overboard through an overboard discharge indicator Two sub-systems (some aircraft) Sub-system 1 CAPT + 3rd occupant CYLINDER regulator solenoid manifold Sub-system 2 F/O + 4th occupant CYLINDER regulator solenoid manifold 2 cylinders · 2 regulators · 4 overpressure safety systems 2 supply solenoid valves · overboard discharge indicator ECAM shows CAPT pressure on the left, F/O on the right
Chapter 27 · Oxygen
6
e-books by eatpl.in · © 2026 · Do not copy or distribute
Some newer aircraft split the cockpit oxygen into two independent sub-systems, which removes the single cylinder as a single point of failure. One sub-system supplies the captain and the third occupant; the other supplies the first officer and the fourth occupant. So there are two high pressure cylinders, two regulators, four overpressure safety systems and two supply solenoid valves, still worked by the one CREW SUPPLY button. Excess pressure is vented overboard through an overboard discharge indicator. On these aircraft the ECAM shows two pressures: the captain bottle on the left and the first officer bottle on the right. Find out which version your airline flies, because the ECAM thresholds differ, as we will see.
Part 1 · Control
The CREW SUPPLY pushbutton On the OXYGEN panel, overhead left ON (pressed in, lights out): valve open, low-pressure oxygen to the masksON is the normal position in flight OFF : valve closed, white OFF lightWith OFF selected, CKPT OXY on the ECAM turns amber The OXYGEN panel (overhead, left) OXYGEN HI ALT LANDING ON MASK MAN ON A U T O PASSENGER SYS ON CREW SUPPLY OFF 1 2 3 4 4 CREW SUPPLY at OFF: white OFF light The supply solenoid valve is closed: no oxygen reaches the masks. Press it in for ON (lights out) Normal position in flight: low-pressure oxygen at the masks. 1, 2 and 3 are the passenger controls (part 3)
Chapter 27 · Oxygen
7
e-books by eatpl.in · © 2026 · Do not copy or distribute
The crew controls the cockpit oxygen with one button: CREW SUPPLY, on the OXYGEN panel on the left of the overhead. It drives the supply solenoid valve. Pressed in, the button is dark and the valve is open, so low pressure oxygen is waiting at every mask. This is the normal position in flight. Released, the valve closes and a white OFF light comes on, our familiar abnormal position colour. Here it is shown at OFF. Note that with CREW SUPPLY at OFF, the CKPT OXY title on the ECAM DOOR/OXY page turns amber, so the system reminds you. The other three items on this panel belong to the passenger system, which we will meet in part three.
Part 2 · Using the crew mask
The mask stowage box Blinker flowmeter : flashes yellow while oxygen flowsOXY ON flag : the mask is still supplied after the doors closeOxygen is supplied as soon as the left flap door opens RESET/TEST slide: tests the system; after use, cuts off the oxygen and the mask microphone A microphone lead with quick-disconnect connects the mask mic The mask stowage box LEFT FLAP RIGHT FLAP N 100% PUSH PRESS TO TEST AND RESET OXY ON 1 2 3 1 Blinker flowmeter: flashes yellow while oxygen flows 2 RESET/TEST slide: tests the system; after use, cuts oxygen and mask mic 3 OXY ON flag: mask still supplied after the doors close
Chapter 27 · Oxygen
8
e-books by eatpl.in · © 2026 · Do not copy or distribute
Each mask lives in a stowage box beside its seat. On the box are three indicators. The blinker flowmeter flashes yellow whenever oxygen is flowing, so you can see each breath. The mask is supplied as soon as the left flap door opens. If the doors close again while the mask is still being supplied, for example because you are wearing it, an OXY ON flag appears. The RESET/TEST slide has two jobs. Pressed and pushed in the arrow direction, it tests the blinker, the regulator supply, the sealing of the system downstream of the valve and the regulator. After the mask has been used, pressing RESET cuts off the oxygen and the mask microphone. The box also holds the microphone lead that connects the mask to the audio system.
Part 2 · Donning
On in five seconds: the donning sequence Squeeze, pull, don, release. Practise it until your hands do it without you.
Squeeze the red grips The right-hand grip unlocks the two-flap door .
Pull the mask out The harness inflates as the mask leaves the box.
Put it on Inflated harness over the head, mask on the face.
Release the grip The harness deflates and holds the mask in place.
Chapter 27 · Oxygen
9
e-books by eatpl.in · © 2026 · Do not copy or distribute
Here is the donning sequence, and you should practise it until it is automatic. One: squeeze the red grips. Squeezing the right hand grip unlocks the two-flap door of the box. Two: pull the mask out. As it comes out, the harness inflates, so it opens up into a big loop. Three: put it straight over your head and onto your face. Four: release the grip. The harness deflates and pulls the mask firmly onto your face. The whole thing takes a few seconds. One extra point if your aircraft has a head-up display: when it is deployed, the captain should turn his or her head to the right, towards the first officer, and the first officer to the left, to don the mask quickly without hitting it.
Part 2 · The regulator
N, 100% and EMERGENCY N / 100% : locked at 100% when the mask comes out of the boxPush it up from underneath: pops up to N ; press again for 100% N : air and oxygen mixture, richer as cabin altitude risesEMERGENCY : press for a few seconds of overpressure; turn for permanentOverpressure needs 100% ; automatic above 30 000 ft cabin The mask-mounted regulator N 100% PUSH EMERGENCY PRESS TO TEST 1 2 3 1 Red grips: squeeze the right one to open the box doors and inflate the harness 2 N / 100% selector · 3 EMERGENCY pressure selector
Chapter 27 · Oxygen
10
e-books by eatpl.in · © 2026 · Do not copy or distribute
The regulator on the mask has two controls. The N slash one hundred per cent selector is locked down at one hundred per cent when you pull the mask out of the box, so you always start with pure oxygen. Push it up from underneath and it pops up to N, normal. Press it again to return to one hundred per cent. The second control is the red EMERGENCY pressure selector. Press it and you get an overpressure for a few seconds; turn it in the direction of the arrow and the overpressure stays on. Overpressure clears fogging from the visor and keeps smoke, smells and ash out of the mask. It is only available with the selector at one hundred per cent, and it starts automatically when the cabin altitude exceeds thirty thousand feet.
Part 2 · Which setting when
Mixture or pure oxygen N : cabin air plus oxygen; more oxygen as the cabin climbs, up to 100%100% : pure oxygen at every cabin altitudeSmoke or fumes : 100%, so no cabin air is breathedEMERGENCY overpressure for a fogged visor or smoke in the maskN saves oxygen when there is no smoke What the mask gives you (illustrative) 0 10 20 30 40 0% 21% 50% 100% cabin altitude (thousands of feet) oxygen in the breathed gas above 30 000 ft: automatic overpressure 100%: pure oxygen at any cabin altitude N: air-oxygen mix, richer as the cabin climbs, up to 100% Shape only: the regulator sets the exact mixture.
Chapter 27 · Oxygen
11
e-books by eatpl.in · © 2026 · Do not copy or distribute
Why have two settings? In N, the regulator mixes cabin air with oxygen. Low in the cabin altitude range you breathe mostly air; as the cabin altitude rises, the mixture gets richer, until at high cabin altitude it delivers one hundred per cent oxygen. That saves oxygen in a simple depressurisation. At one hundred per cent you breathe pure oxygen at any cabin altitude, with no cabin air at all, which is exactly what you want when there is smoke or fumes in the cockpit. On top of that, the emergency overpressure pushes oxygen out round the seal, keeping smoke out and clearing a fogged visor. The graph shows the shape only; the regulator decides the exact mixture.
Part 2 · Indications
Crew oxygen on the DOOR/OXY page CKPT OXY pressure, top right of the DOOR/OXY pageGreen at or above 800 PSI Pulses green below 800 PSI and the page is called automatically Amber below 400 PSI ; on ground, amber half frame below 1 500 PSI REGUL LO PR amber: low-pressure circuit low (50 PSI )DOOR/OXY CKPT OXY 1850 PSI SLIDE SLIDE SLIDE SLIDE SLIDE SLIDE TAT +19 °C SAT +18 °C 23 H 56 GW 60300 KG 1 2 1 CKPT OXY title: white normally 2 crew oxygen pressure
Chapter 27 · Oxygen
12
e-books by eatpl.in · © 2026 · Do not copy or distribute
The crew oxygen pressure is shown at the top right of the ECAM DOOR slash OXY page. On the most common installation it is green when the pressure is eight hundred P S I or more. Below eight hundred it pulses green, and the DOOR slash OXY page is displayed automatically, to draw your attention. Below four hundred it turns amber. On the ground there is one more cue: an amber half frame appears round the value when the pressure is below one thousand five hundred P S I. That tells you to check that the bottle holds at least the minimum crew oxygen for your flight, which is in the limitations. Finally, REGUL LO PR in amber means the pressure in the low pressure circuit, after the regulator, is low, at fifty P S I.
Part 2 · Indications
Four pictures of the crew oxygen pressure DOOR/OXY CKPT OXY 1850 PSI SLIDE SLIDE SLIDE SLIDE SLIDE SLIDE Normal green, at or above 800 PSI DOOR/OXY CKPT OXY 720 PSI SLIDE SLIDE SLIDE SLIDE SLIDE SLIDE Below 800 PSI value pulses green; page called DOOR/OXY CKPT OXY 350 PSI SLIDE SLIDE SLIDE SLIDE SLIDE SLIDE Below 400 PSI value and CKPT OXY amber DOOR/OXY CKPT OXY 1300 PSI On ground, below 1 500 amber half frame: check minimum Values for the most common installation. Other aircraft use other thresholds: see the variants table. CKPT OXY title turns amber: below 400 PSI , low pressure detected, or CREW SUPPLY OFF .
Chapter 27 · Oxygen
13
e-books by eatpl.in · © 2026 · Do not copy or distribute
Here are the four pictures side by side. On the left, normal: one thousand eight hundred and fifty P S I in green. Next, the pressure has dropped below eight hundred: the value pulses green and the page comes up by itself. Third, below four hundred: the value is amber, and so is the CKPT OXY title above it. That title also turns amber when a low pressure is detected, or when CREW SUPPLY is selected OFF. On the right, on the ground before departure with one thousand three hundred P S I: the amber half frame tells you to check the minimum. Notice it is only a reminder; the green value itself does not change colour until the lower thresholds.
Part 2 · Thresholds differ
Know your aircraft: three sets of numbers The colour logic is identical; only the numbers change with the cylinder installation. All values in PSI.
Installation Normal Advisory Amber Ground half frame Most common (this course) ≥ 800 green < 800 pulses, page called < 400 < 1 500 Some earlier aircraft ≥ 600 green < 600 pulses, page called < 300 < 1 000 Two-cylinder aircraft (CAPT left, F/O right) ≥ 500 green < 500 pulses, page called < 200 (either bottle) < 800
Worked example (most common installation): on the ground the value reads 1 300 PSI . 1 300 < 1 500, so the half frame is shown: check the minimum crew oxygen pressure in the limitations before departure.
Chapter 27 · Oxygen
14
e-books by eatpl.in · © 2026 · Do not copy or distribute
The colour logic is always the same, but the numbers depend on the oxygen installation, so you must know which one your aircraft has. On the most common installation, which we use in this course, it is green from eight hundred, pulsing below eight hundred, amber below four hundred, and the ground half frame below one thousand five hundred. Some earlier aircraft use six hundred, three hundred and one thousand. The two cylinder aircraft use five hundred, two hundred and eight hundred, for each bottle, with the captain bottle on the left and the first officer bottle on the right. A worked example: on the ground you read one thousand three hundred. That is below one thousand five hundred, so you check the minimum pressure table before you go.
Part 2 · Mask test
Testing the mask before flight CREW SUPPLY ON, LOUDSPEAKERS on, ACP set to INT Hold RESET/TEST : blinker yellow briefly, then black Add EMERGENCY : blinker stays yellow, oxygen heard Release, then EMERGENCY alone: blinker stays black Check EMERGENCY knob not turned , N/100% at 100% Mask test: what to look and listen for Before CREW SUPPLY ON · LOUDSPEAKERS ON · ACP: INT reception out, INT/RAD to INT 1 Press and hold RESET/TEST: blinker yellow briefly, then black 2 Keep holding, press EMERGENCY: blinker stays yellow, oxygen heard in the loudspeakers 3 Release: RESET/TEST back up, N/100% at 100% 4 Press EMERGENCY again: blinker stays black (mask not supplied) 5 EMERGENCY knob not turned (no permanent overpressure) Warn the ground crew on the intercom first: the test is loud.
Chapter 27 · Oxygen
15
e-books by eatpl.in · © 2026 · Do not copy or distribute
Before flight you test your mask without taking it out. First, warn any ground crew on the interphone, because the test is loud in their headsets. Check CREW SUPPLY is on, the loudspeakers are on, and on your audio panel the interphone reception is selected and the transmit switch is at INT. Now press and hold the RESET slash TEST slide in the arrow direction: the blinker should flash yellow briefly and then go black. Keep holding and press the EMERGENCY selector: the blinker stays yellow for as long as you press, and you hear oxygen flowing in the loudspeakers. Release everything. Check the slide is back up and the selector is at one hundred per cent. Press EMERGENCY alone: the blinker must stay black, proving the mask is not being supplied. Finally, check the knob is not turned.
Part 2 · After use
Restowing the mask Coil the hose in the bottom of the box Fold the harness; regulator fully seated Close the doors, press RESET/TEST : OXY ON flag must disappear Press EMERGENCY: blinker stays black ; set 100% Never leave EMERGENCY on: it can empty the cylinder Stowing the mask after use 1 Coil the hose into the bottom of the stowage box 2 Put the rest of the hose in the middle of the mask; fold the harness 3 Place the mask: regulator fully seated against its stop 4 Close the doors; press RESET/TEST fully: OXY ON flag disappears 5 Press EMERGENCY: blinker must stay black 6 Return the N/100% selector to 100% Caution: leaving the selector at EMERGENCY can empty the crew oxygen cylinder.
Chapter 27 · Oxygen
16
e-books by eatpl.in · © 2026 · Do not copy or distribute
After using the mask you must restow it properly, or it may not come out cleanly next time. Coil the hose and lay it in the bottom of the box. Put the rest of the hose in the middle of the mask and fold the two harness halves together. Place the mask in the box with the regulator fully seated against its stop. Close the doors, then press the RESET slash TEST button fully. When you release it, the OXY ON flag must disappear completely, which tells you the supply to this mask is cut. Press the EMERGENCY selector and check the blinker stays black, then return the N slash one hundred per cent selector to one hundred. And remember the caution: leaving the emergency overpressure on can empty the crew oxygen cylinder.
Part 3 · Passenger oxygen
Chemical generators in the cabin For depressurisation only Oxygen made by chemical generators Each generator feeds 2, 3 or 4 masks Containers above the seats , in lavatories , galleys and at cabin crew stations Some aircraft use gaseous generators in the lavatories Where the passenger masks are container container cargo Containers: above the passenger seats, in the lavatories, in each galley and at each cabin crew station.
Chapter 27 · Oxygen
17
e-books by eatpl.in · © 2026 · Do not copy or distribute
The passenger and cabin crew oxygen is completely separate from the cockpit system, and it is only for depressurisation. There is no oxygen piping along the cabin. Instead, the oxygen is made where it is needed, by chemical generators. Each generator feeds a group of two, three or four masks, all stowed in one container. The containers are above the passenger seats, in the lavatories, in each galley and at every cabin crew station, so everyone in the cabin has a mask within reach. On some aircraft the lavatory units use small gaseous generators instead of chemical ones. So the important questions are when the masks drop, and what starts the oxygen flowing.
Part 3 · Passenger oxygen
What happens when the masks drop Container door latch opens : the masks drop Oxygen starts when the passenger pulls the mask towards the seat Pure oxygen under positive pressure , about 13, 15 or up to 22 min The generator gets hot : a burning smell or a little smoke can be normal A reset rearms the system after restowing; a manual release tool exists Masks drop, a pull starts the oxygen container container cargo Containers: above the passenger seats, in the lavatories, in each galley and at each cabin crew station.
Chapter 27 · Oxygen
18
e-books by eatpl.in · © 2026 · Do not copy or distribute
Watch a container in action. When the release signal comes, an electrical latch opens the container door and the masks drop on their tubes. Nothing flows yet. Oxygen generation begins only when the passenger pulls the mask towards the seat, which fires the generator. From then on the mask receives pure oxygen under positive pressure until the generator is exhausted, after about thirteen, fifteen or up to twenty two minutes depending on the installation. The chemical reaction produces heat, so the generator gets hot. Passengers and crew may notice a smell of burning, a little smoke or a rise in cabin temperature, and this can be normal. After use the masks can be restowed and a reset rearms the system. If the electrical release fails, the crew has a manual tool to open the doors.
Part 3 · Release logic
Three ways to open the containers AUTO: cabin altitude above 14 000 ft (16 000 with HI ALT) MAN: MASK MAN ON pressed (guard lifted) Manual release tool cabin crew, at each container OR electrical PASSENGER SYS ON white light on the overhead Recorded PA message OR Door latches containers open container 2, 3 or 4 masks per container oxygen flows when a mask is pulled The recorded announcement is fitted on some aircraft only. AUTO above 14 000 ft (16 000 ft with HI ALT LANDING) or MASK MAN ON → electrical release · manual tool → mechanical release.
Chapter 27 · Oxygen
19
e-books by eatpl.in · © 2026 · Do not copy or distribute
There are three ways to open the containers. The first is automatic: when the cabin pressure altitude exceeds fourteen thousand feet, or sixteen thousand on aircraft set up for high altitude airfields, the system releases the masks by itself. The second is manual from the cockpit: the flight crew can override the automatic control with the MASK MAN ON button. Either of these sends an electrical signal that opens the door latches, lights the PASSENGER SYS ON light and, on aircraft that have it, starts a recorded announcement on the passenger address system. The third way is purely mechanical: if there is an electrical failure, the cabin crew can open each container door with the manual release tool.
Part 3 · Controls
Passenger oxygen controls MASK MAN ON (red guard): AUTO normally; pressed: doors open HI ALT LANDING (if installed): OFF 14 000 ft, ON 16 000 ft PASSENGER SYS ON : white, when the door release is activatedSYS ON stays on until TMR RESET is pressed TMR RESET (maintenance panel): FAULT white if the latch solenoids are energised over 30 s Manual release on the OXYGEN panel OXYGEN HI ALT LANDING ON MASK MAN ON A U T O PASSENGER SYS ON CREW SUPPLY OFF 1 2 3 4 2 MASK MAN ON pressed: doors open, 3 SYS ON lights SYS ON stays lit until maintenance presses TMR RESET. 1 HI ALT LANDING ON: threshold 16 000 ft OFF: 14 000 ft (both +250 / −750 ft). TMR RESET (maintenance panel): FAULT white when the latch solenoids stay energised over 30 s.
Chapter 27 · Oxygen
20
e-books by eatpl.in · © 2026 · Do not copy or distribute
Three of the four items on the OXYGEN panel belong to the passenger system. MASK MAN ON sits under a red guard that keeps it in AUTO. Lift the guard and press it, and the mask doors open. The HI ALT LANDING button, fitted to some aircraft, moves the automatic threshold: OFF, the masks drop above fourteen thousand feet; ON, above sixteen thousand, for operations at high altitude airfields. The PASSENGER SYS ON light comes on in white as soon as the door release is activated, automatically or manually, and it stays on until a maintenance engineer presses the TMR RESET button on the maintenance panel. That TMR RESET button also has a white FAULT light, which comes on if the door latch solenoids remain energised for more than thirty seconds.
Part 3 · The numbers
Exactly when the masks drop Nominal 14 000 ft cabin altitude, tolerance +250 / −750 ft So the masks may drop between 13 250 and 14 250 ft HI ALT LANDING ON: 16 000 ft , i.e. 15 250 to 16 250 ft Exam trap: the tolerance is not symmetrical Crew can release earlier with MASK MAN ON When do the masks drop? 8 000 10 000 12 000 14 000 16 000 18 000 normal: 14 000 (+250 / −750) HI ALT LANDING ON: 16 000 (+250 / −750) nominal drop point time (illustrative depressurisation) cabin altitude (ft) Tolerance +250 / −750 ft: masks may drop anywhere from 13 250 to 14 250 ft (15 250 to 16 250 with HI ALT).
Chapter 27 · Oxygen
21
e-books by eatpl.in · © 2026 · Do not copy or distribute
Let us do the arithmetic, because the tolerance is a classic trap. The nominal threshold is fourteen thousand feet of cabin altitude, with a tolerance of plus two hundred and fifty and minus seven hundred and fifty feet. So the masks may drop anywhere from fourteen thousand minus seven hundred and fifty, which is thirteen thousand two hundred and fifty feet, up to fourteen thousand plus two hundred and fifty, which is fourteen thousand two hundred and fifty feet. With HI ALT LANDING selected ON, the same tolerance applies to sixteen thousand feet, giving fifteen thousand two hundred and fifty to sixteen thousand two hundred and fifty. The graph shows a cabin climbing in a depressurisation and crossing the band. And remember, the crew never has to wait: MASK MAN ON releases the masks at any time.
Part 3 · ECAM
The OXY PAX ON memo Appears as soon as the cabin masks drop , auto or manual Green : both CPCs detect excessive cabin altitudeAmber : one or both CPCs do not detect itAmber prompts the question: why are the masks down? Fitted on some aircraft OXY PAX ON memo OXY PAX ON Both CPCs detect excessive cabin altitude: automatic drop OXY PAX ON One or both CPCs do NOT detect it: e.g. masks released manually Shown as soon as the masks drop, automatically or manually (some aircraft).
Chapter 27 · Oxygen
22
e-books by eatpl.in · © 2026 · Do not copy or distribute
On many aircraft, the ECAM shows an OXY PAX ON memo as soon as the cabin masks drop, whether automatically or manually. Its colour carries information. It is green when both cabin pressure controllers detect an excessive cabin altitude: the masks are down because the cabin really is too high, which is what you expect. It is amber when one or both controllers do not detect an excessive cabin altitude. That is a prompt to ask why the masks are down, for example after an unintended manual release, or because a controller disagrees. In either case, the passenger oxygen is now flowing for a limited time, so it shapes your descent and diversion planning.
Part 4 · Portable oxygen
The protective breathing equipment One PBE (hood) in a container, right aft of the cockpit Protects the eyes and lungs of one crew member: fire, smoke, fumes, depressurisation Chemical air regeneration in the breathing key; oronasal maskLasts at least 15 min Serviceability: yellow indicator cracked , or red indicator = do not use Protective breathing equipment (PBE) handle PBE container with serviceability indicator visor oronasal breathing key (air regeneration) lanyard At least 15 min · one crew member · eyes and lungs Right aft of the cockpit
Chapter 27 · Oxygen
23
e-books by eatpl.in · © 2026 · Do not copy or distribute
For fire fighting, the cockpit carries a protective breathing equipment unit, a hood stored in a container at the right aft of the cockpit. It protects the eyes and the breathing of one crew member who has to fight a fire or work in smoke or noxious gases, and it also works in a depressurisation. Inside the hood is an oronasal mask. You breathe in through it, and your exhaled breath goes back to a chemical air regeneration system in the breathing key, which regenerates it so that it can be breathed again. It lasts at least fifteen minutes. Check it on the preflight: if the container has a yellow indicator that is cracked, or a red and green indicator showing red, the protection may be insufficient and the hood must not be used. On some older aircraft a similar smoke hood uses a solid oxygen source, also for fifteen minutes.
Part 4 · Using the hood
Putting on the PBE Practise on a trainer: in real smoke you will do it by feel.
Unpack Take the unit out of its case; tear the strip and remove the protective bag .
Over the head Stretch the neck seal with both hands and pull the hood over your head.
Inner mask Adjust the oronasal mask over nose and mouth.
Activate Pull the lanyard down to start the air regeneration system.
Chapter 27 · Oxygen
24
e-books by eatpl.in · © 2026 · Do not copy or distribute
Using the hood takes four steps. One: take the unit out of its case and remove the hood from its protective bag by tearing off the strip. Two: put both hands inside the neck seal, stretch it open, and pull the hood down over your head. Three: adjust the inner oronasal mask over your nose and mouth. Four: pull the lanyard down firmly to activate the air regeneration system. From then on you have at least fifteen minutes of protection. Remember that the hood protects one wearer only: it is for the crew member who has to fight the fire.
Summary
Oxygen on one page Three systems Cockpit fixed (depress, smoke, fumes) · cabin fixed (depress) · portable (crew protection, first aid).
Crew system HP cylinder LH lower fuselage → regulator → solenoid valve (CREW SUPPLY) → manifold → 3 or 4 masks. Overpressure → safety port.
Mask Squeeze red grips, harness inflates. 100% when taken out. N = mixture. EMERGENCY: press = seconds, turn = permanent; auto above 30 000 ft.
ECAM Green ≥ 800 · pulse < 800 (page) · amber < 400 · ground half frame < 1 500. REGUL LO PR at 50 PSI.
Cabin Chemical generators, 2/3/4 masks each. Flow starts on pulling the mask, ~13–22 min, heat and smell normal.
Release Auto 14 000 ft (+250/−750), 16 000 with HI ALT. MASK MAN ON. Manual tool. SYS ON until TMR RESET.
Memo OXY PAX ON green: both CPCs see high cabin altitude. Amber: one or both do not.
PBE Right aft, hood with chemical regeneration, ≥ 15 min. Cracked yellow or red indicator: do not use.
Chapter 27 · Oxygen
25
e-books by eatpl.in · © 2026 · Do not copy or distribute
Here is the whole chapter on one page. Three systems: the cockpit fixed system for depressurisation, smoke and fumes, the cabin fixed system for depressurisation, and portable equipment for crew protection and first aid. The crew oxygen flows from a cylinder through a regulator and the CREW SUPPLY solenoid valve to three or four masks. The mask comes out at one hundred per cent, N gives a mixture, and EMERGENCY gives overpressure, automatically above thirty thousand feet. On the ECAM, green from eight hundred, pulsing below, amber below four hundred, and a half frame on the ground below one thousand five hundred. The passenger masks drop at fourteen thousand feet, plus two hundred and fifty minus seven hundred and fifty, and flow for up to twenty two minutes. And the hood lasts at least fifteen minutes.