A320 Aircraft Systems · Chapter 28
Pneumatic and Bleed Air Where the A320 gets its high-pressure air, how two computers select, regulate, cool and share it, and how leaks are caught before they become fires.
A I R A I R C O N D C O N D PACK 1 PACK 2 ENG 1 BLEED APU BLEED ENG 2 BLEED RAM AIR FAULT OFF FAULT OFF FAULT ON ON X BLEED SHUT AUTO OPEN BLEED 24 °C C H 50 °C LO HI 25 °C C H 230 °C LO HI RAM AIR 44 180 PSI °C 1 IP HP 44 180 PSI °C 2 IP HP TAT +12 °C SAT -6 °C 10 H 42 GW 64300 KG © 2026 eatpl.in. For the personal study of eatpl.in students only. Do not copy or distribute.
e-books by eatpl.in · © 2026 · Do not copy or distribute
Welcome to the pneumatic system, chapter thirty-six. Almost everything that keeps the cabin comfortable starts here: hot, high-pressure air taken from the engines, the APU or a ground cart. That air conditions and pressurizes the cabin, starts the engines, heats the wing leading edges and pressurizes the hydraulic reservoirs. In this lesson we follow the air from the compressor stage where it is taken, through the valves that select and regulate it, the precooler that cools it, and the crossbleed duct that shares it, and we learn how two bleed monitoring computers watch every duct for leaks. We finish on the overhead panel and the ECAM BLEED page.
Lesson roadmap
The pneumatic system in four parts ATA chapter 36 . Two Bleed Monitoring Computers , the overhead panel and the ECAM control and monitor the system.
1 · Sources and users Engines, APU , HP ground ; packs, start, anti-ice, reservoirs. The crossbleed duct and the BMCs .
2 · Engine bleed IP / HP selection, the bleed valve (PRV), the overpressure valve , the precooler and fan air valve.
3 · APU, crossbleed, leaks APU bleed, the X BLEED valve, leak detection loops and what each leak closes; BMC failure .
4 · Cockpit The ENG BLEED , APU BLEED and X BLEED controls, the ECAM BLEED page and its limits.
Chapter 28 · Pneumatic and Bleed Air
2
e-books by eatpl.in · © 2026 · Do not copy or distribute
Here is our route through chapter thirty-six. Part one is the big picture: where high-pressure air comes from, who uses it, and how the crossbleed duct joins everything together under the watch of two bleed monitoring computers. Part two follows the air through one engine bleed system: which compressor stage it comes from, how its pressure is regulated and limited, and how the precooler brings its temperature down. Part three covers the APU bleed, the crossbleed valve and leak detection, with what happens when a leak is found or a computer fails. Part four is the cockpit: the bleed pushbuttons and the X BLEED selector on the AIR COND panel, and the ECAM BLEED page with its symbols, colours and limits.
Part 1 · Sources and users
Three sources, one duct, many users X BLEED valve ENG 1 bleed IP / HP stages ENG 2 bleed IP / HP stages APU load compressor HP ground connection Wing anti-ice PACK 1 Cargo heating* Hyd reservoirs + water tank PACK 2 Wing anti-ice FTIS* engine starting engine starting * where installed (cargo heating, fuel tank inerting) Controlled by BMC 1 + BMC 2, the overhead panel and the ECAM. Sources: engine bleed , APU load compressor , HP ground connection . The crossbleed valve joins or separates the engine 1 and engine 2 sides.
Chapter 28 · Pneumatic and Bleed Air
3
e-books by eatpl.in · © 2026 · Do not copy or distribute
The pneumatic system supplies high-pressure air to a long list of users: air conditioning, engine starting, wing anti-icing, water pressurization and hydraulic reservoir pressurization, and, on aircraft that have them, forward and aft cargo heating and the fuel tank inerting system. That air has three sources: the two engine bleed systems, the APU load compressor and the high-pressure ground connection. An external high-pressure source may also be used for air conditioning. All of them meet in the crossbleed duct, which connects the two engine bleed systems and receives air from the APU and ground sources when appropriate. A valve on that duct, the crossbleed valve, lets you join or separate the engine one side and the engine two side. Check valves stop air flowing back into the APU or out through the ground connection.
Part 1 · On the aircraft
Where the hot air flows X BLEED valve ENG 1 bleed IP / HP stages ENG 2 bleed IP / HP stages APU load compressor HP ground connection Wing anti-ice PACK 1 Cargo heating* Hyd reservoirs + water tank PACK 2 Wing anti-ice FTIS* engine starting engine starting * where installed (cargo heating, fuel tank inerting) Controlled by BMC 1 + BMC 2, the overhead panel and the ECAM. Engine bleed → packs ; the crossbleed duct runs across the wing box; the APU duct comes forward from the tail; wing anti-ice runs along the leading edge.
Chapter 28 · Pneumatic and Bleed Air
4
e-books by eatpl.in · © 2026 · Do not copy or distribute
Now see it on the aircraft. Each engine bleed system takes air from the engine compressor, cools it in the precooler, and sends it towards the wing root, where it feeds the packs in the belly fairing, the biggest users of all. Across the centre of the aircraft runs the crossbleed duct, joining the left and right systems, with the crossbleed valve in the middle. From the tail cone, the APU duct brings air from the APU load compressor forward to the crossbleed duct. And from each side, a duct runs out along the wing leading edge to the anti-iced slats. Every one of these ducts carries air hot enough to damage the structure if it leaks, which is why we will spend time on leak detection later in this lesson.
Part 2 · Engine bleed
One engine bleed system, valve by valve ENG 1 HP compressor IP check valve HP valve 36 ± 4 psi* bleed valve shut-off + PRV overpressure valve ENG 1 starter precooler to the crossbleed duct and the users fan air valve overboard fan air 45 ± 5 psi* closes > 75 psi ≈ 200 °C * earlier aircraft; later aircraft: HP 65 ± 15 psi, delivery 42 ± 3 psi (dual) or 50 ± 3 psi (single bleed) hot bleed air after the precooler fan air (cooling) Each engine bleed system selects the compressor stage, regulates pressure and regulates temperature .
Chapter 28 · Pneumatic and Bleed Air
5
e-books by eatpl.in · © 2026 · Do not copy or distribute
Here is one engine bleed system laid out from left to right. Air leaves the high pressure compressor from one of two ports. The intermediate pressure port, I P, has a check valve; the high pressure port, H P, has the H P valve. Downstream of their junction sits the bleed valve, which is both a shut-off valve and a pressure regulating valve. Next comes the overpressure valve, a safety device that closes if the pressure goes too high. Then the duct to the engine starter is tapped off, and the air enters the precooler, a heat exchanger cooled by air from the engine fan, controlled by the fan air valve, with the fan air dumped overboard. What comes out, at about two hundred degrees, goes to the crossbleed duct and the users. The two engines have identical systems.
Part 1 · Control
Bleed Monitoring Computers One BMC per engine bleed system: BMC 1 , BMC 2 Inputs: bleed pressure , temperature , valve positions Linked to each other and to the systems that use the air Outputs: indications and warnings to ECAM and CFDS Each bleed valve: pneumatically operated , electrically controlled by its BMC One BMC fails: the other takes over most of the monitoring Two Bleed Monitoring Computers BMC 1 engine 1 side BMC 2 engine 2 side link bleed pressure bleed temperature valve positions same inputs for engine 2 ECAM + CFDS indications, warnings bleed valves electrical control other systems that use air or data If one BMC fails, the other takes over most of the monitoring.
Chapter 28 · Pneumatic and Bleed Air
6
e-books by eatpl.in · © 2026 · Do not copy or distribute
Each engine bleed system is controlled and monitored by its own bleed monitoring computer, B M C one for engine one and B M C two for engine two. Each computer receives the bleed pressure, the bleed temperature and the positions of the valves. Each is connected to the systems that use the air or its information, and to the other B M C. Each sends indications and warnings to the ECAM and maintenance data to the C F D S. An important design point: the bleed valve is moved by air pressure, it is pneumatically operated, but it is told what to do electrically by its B M C. If one computer fails, the other takes over most of the monitoring functions, but not all of them, as we will see when we study a B M C failure.
Part 2 · Air bleed selection
IP normally, HP when the engine is slow Normally from the IP stage : minimum fuel penalty At low engine speed , IP pressure and temperature are too low: HP stage HP air regulated at 36 ± 4 psi (later aircraft: 65 ± 15 psi ) The IP check valve closes so HP air cannot flow into the IP stage The bleed valve downstream does the shut-off and the final regulation IP normally, HP at low engine speed High power: IP stage HP compressor IP HP check valve HP valve IP check valve open HP valve closed Low power: HP stage HP compressor IP HP check valve HP valve IP check valve closed HP valve open, regulating IP saves fuel; HP keeps the pressure up when the engine is slow.
Chapter 28 · Pneumatic and Bleed Air
7
e-books by eatpl.in · © 2026 · Do not copy or distribute
Where should the air come from? Air taken from a later compressor stage has been squeezed harder, so it costs the engine more fuel. So the A320 normally bleeds from the intermediate pressure stage, to keep the fuel penalty to a minimum. But when the engine is slow, at idle in descent or on the ground, the intermediate pressure air is too weak and too cool. Then the system opens the H P valve and bleeds from the high pressure stage, regulating it at thirty-six psi, plus or minus four, on earlier aircraft, or sixty-five, plus or minus fifteen, on later aircraft. Watch the model: as the engine slows, the H P valve opens and the I P check valve shuts, so that high pressure air cannot flow backwards into the intermediate stage. When the engine speeds up again, the H P valve closes.
Part 2 · The HP valve
When does the HP valve close? Pneumatically : low upstream pressure, or excessive upstream pressureElectrically : whenever the bleed valve is closed electricallySome aircraft: overpressure upstream with WAI off , two packs ON , above 15 000 ft Later aircraft: 30 s after the bleed valves close because APU bleed is ON ENG BLEED pb OFF closes the bleed valve and the HP valve The HP valve closes… pneumatically low upstream pressure pneumatically excessive upstream pressure electrically whenever the bleed valve is closed electrically electrically, some aircraft overpressure upstream with WAI off, two packs ON, above 15 000 ft later aircraft 30 s after the bleed valves close because APU bleed is ON HP stage regulated pressure earlier aircraft: 36 ± 4 psi later aircraft: 65 ± 15 psi OFF on the ENG BLEED pb closes bleed valve + HP valve
Chapter 28 · Pneumatic and Bleed Air
8
e-books by eatpl.in · © 2026 · Do not copy or distribute
The H P valve closes automatically in several ways. Pneumatically, it closes when the upstream pressure is too low to be useful, or too high, which is what happens as the engine accelerates and the intermediate stage takes over. Electrically, it closes whenever the bleed valve is closed electrically, for example when you switch the ENG BLEED pushbutton off: the OFF selection closes both the bleed valve and the H P valve. Some aircraft add an electrical closure for overpressure upstream of the H P valve with wing anti-ice off, two packs on and the aircraft above fifteen thousand feet. And on later aircraft, if the bleed valves close because APU bleed is on, the H P valves close thirty seconds later. Know which version you fly, but the main idea is the same everywhere.
Part 2 · Pressure
Regulation and the overpressure valve The bleed valve : downstream of the HP / IP junction; shut-off and pressure regulating Delivers 45 ± 5 psi (fluctuating 38–56 psi at high power up to FL 100) Later aircraft: 42 ± 3 psi dual bleed, 50 ± 3 psi single bleed Regulation fails: the overpressure valve closes above 75 psi Closes pneumatically below 8 psi upstream (later: 15 psi ) or on return flow Delivered pressure (earlier aircraft) 0 20 40 60 80 100 120 0 15 30 45 60 75 90 38–56 psi band: high power, up to FL100 75 psi: overpressure valve closes ECAM amber 57–60 psi normal: 45 ± 5 psi regulation failed → OPV shuts at 75 < 8 psi: shut pressure upstream of the bleed valve (psi) psi delivered Later aircraft: 42 ± 3 psi dual bleed · 50 ± 3 psi single bleed · shut < 15 psi
Chapter 28 · Pneumatic and Bleed Air
9
e-books by eatpl.in · © 2026 · Do not copy or distribute
The bleed valve, downstream of the junction of the two ports, does two jobs. It is a shut-off valve, and it is a pressure regulating valve that holds the delivered pressure at forty-five psi, plus or minus five, on earlier aircraft. At high power, in the take-off and climb up to flight level one hundred, the pressure may fluctuate between thirty-eight and fifty-six psi, with up to sixteen psi peak to peak. Later aircraft regulate to forty-two psi with two engine bleeds and fifty psi with one. Look at the graph. Below eight psi upstream, the valve stays shut. Above that, the delivered pressure rises and then levels off. If the regulation fails, the pressure keeps climbing with the engine, until the overpressure valve slams shut above seventy-five psi. The ECAM turns the pressure amber well before that, between fifty-seven and sixty psi.
Part 2 · Bleed valve logic
When is the bleed valve fully closed? How Cause Notes Pneumatically upstream pressure below 8 psi (later aircraft: 15 psi ); return flow no air to work with, or air flowing backwards By the crew ENG BLEED pb OFF ; ENG FIRE pb pushedOFF also closes the HP valve By the BMC overtemperature , overpressure , leak , starter valve open , APU bleed ON all aircraft By the BMC engine shutdown most aircraft By the BMC, later aircraft no bleed consumers; HP valve failed open; bleed temperature lost; fan duct burst (FADEC) LEAP-1A: fan duct burst Exception APU bleed ON with X BLEED SHUT : engine bleed valve 2 stays open APU feeds side 1 only
Learn the BMC list as a set: overtemperature, overpressure, leak, starter valve open, APU bleed ON (+ engine shutdown on most aircraft).
Chapter 28 · Pneumatic and Bleed Air
10
e-books by eatpl.in · © 2026 · Do not copy or distribute
When is the bleed valve fully closed? Pneumatically, when the upstream pressure drops below eight psi, or fifteen on later aircraft, and when there is return flow, air trying to go backwards into the engine. By the crew, with the ENG BLEED pushbutton off, or by pushing the ENG FIRE pushbutton. And by the B M C, for overtemperature, overpressure, a leak, an open starter valve, APU bleed being on, and on most aircraft an engine shutdown. Later aircraft add more: no bleed consumers, an H P valve failed open, loss of the bleed temperature, and a fan duct burst detected by the FADEC. There is one exception to remember: with APU bleed on and the crossbleed valve shut, engine bleed valve two stays open, because the APU cannot reach the engine two side.
Part 2 · Temperature
The precooler and the fan air valve Precooler : air-to-air heat exchanger downstream of the bleed valve Cooled by fan air from the engine, then dumped overboard Regulates the bleed air to about 200 °C Later aircraft: 160 °C in climb or hold with two engine bleeds and no wing anti-ice The fan air valve controls the cooling flow; a spring keeps it closed without pressure Precooler and fan air valve precooler hot bleed air from the bleed valve to the users ≈ 200 °C fan air valve spring: closed without pressure fan air overboard more fan air → cooler bleed air Later aircraft: 160 °C in climb or hold, two bleeds, no WAI
Chapter 28 · Pneumatic and Bleed Air
11
e-books by eatpl.in · © 2026 · Do not copy or distribute
Bleed air leaves the compressor far too hot for ducts that run through the wing and the fuselage. So downstream of the bleed valve, it passes through the precooler, an air-to-air heat exchanger. Cold air taken from the engine fan flows across the precooler and is then dumped overboard. The amount of fan air is controlled by the fan air valve: the more it opens, the more cooling. Watch the gauge: as the fan air valve opens, the outlet temperature comes down and is regulated to about two hundred degrees. Later aircraft regulate to about one hundred and sixty degrees in climb or hold with two engine bleeds and no wing anti-ice. One detail: a spring keeps the fan air valve closed when there is no air pressure to open it.
Part 3 · APU bleed
APU bleed air From the APU load compressor , on the ground and in flight The APU bleed valve is a shut-off valve, controlled by the APU BLEED pb ON and APU speed above 95 % : valve opens, X BLEED opens , engine bleeds close Auto close: APU leak , left wing leak , pylon 1 leak (not during engine start) A check valve protects the APU when air comes from another source APU bleed air X BLEED opens (AUTO) ENG 1 bleed closes ENG 2 bleed closes APU bleed valve check valve APU load compressor APU BLEED ON + APU speed > 95 % → valve opens Auto close: APU leak, LEFT wing leak, pylon 1 leak (except during engine start) · ground and flight
Chapter 28 · Pneumatic and Bleed Air
12
e-books by eatpl.in · © 2026 · Do not copy or distribute
The APU load compressor can supply the pneumatic system on the ground and in flight. Its air passes the APU bleed valve, a simple shut-off valve, controlled by the APU BLEED pushbutton on the AIR COND panel. When you select it ON, and the APU speed is above ninety-five per cent, the APU bleed valve opens, the crossbleed valve opens automatically and the engine bleed valves close automatically. That last point stops the engines and the APU feeding the same duct against each other. If a leak is found in the APU duct, in the left wing or in pylon one, the APU bleed valve closes automatically, except during engine start. Why the left side? Because the APU duct joins the crossbleed duct on the engine one side. And a check valve near the crossbleed duct protects the APU when the air comes from another source.
Part 3 · Crossbleed
The crossbleed valve On the crossbleed duct : isolates or interconnects the two engine sides Two electric motors: one for automatic , one for manual mode X BLEED rotary selector on the AIR COND panel: SHUT , AUTO , OPEN AUTO : open when the APU bleed valve is openAUTO : closes on a wing, pylon or APU leak (except during engine start)The crossbleed valve engine 1 side engine 2 side M AUTO motor M MAN motor SHUT AUTO OPEN X BLEED AUTO open if the APU bleed valve is open; shut if it is closed, or on a wing, pylon or APU leak OPEN valve open (manual motor) SHUT valve shut (manual motor) Rotary selector on the AIR COND panel, electrical control.
Chapter 28 · Pneumatic and Bleed Air
13
e-books by eatpl.in · © 2026 · Do not copy or distribute
The crossbleed valve sits on the crossbleed duct and either isolates the two engine bleed systems or interconnects them. It is controlled electrically from the X BLEED rotary selector on the AIR COND panel, and it has two electric motors, one for the automatic mode and one for the manual mode. In AUTO, the normal position, the valve is open when the APU bleed valve is open, and closed when the APU bleed valve is closed. It also closes automatically if a wing, pylon or APU leak is detected, except during an engine start. The OPEN and SHUT positions drive it directly with the manual motor, for example when an ECAM procedure asks you to supply both sides from one engine. In normal flight, with both engine bleeds on, the valve is shut and each engine feeds its own side.
Part 3 · Worked example
APU BLEED ON: X BLEED AUTO or SHUT? APU BLEED ON, X BLEED at AUTO PACK 1 PACK 2 ENG 1 bleed closed ENG 2 bleed closed APU bleed open X BLEED open APU BLEED ON, X BLEED at SHUT PACK 1 PACK 2 ENG 1 bleed closed ENG 2 bleed open APU bleed open X BLEED shut APU air feeds both sides; both engine bleed valves close. APU feeds side 1; engine bleed valve 2 stays open for side 2. With APU bleed ON and the crossbleed valve SHUT , engine bleed valve 2 remains open .
Chapter 28 · Pneumatic and Bleed Air
14
e-books by eatpl.in · © 2026 · Do not copy or distribute
Let us apply the logic to two cases with the APU bleed on. On the left, the X BLEED selector is at AUTO. The APU bleed valve opens, the crossbleed valve opens automatically, and both engine bleed valves close: the APU is now the only source, feeding both packs through the open crossbleed. On the right, the crew has set X BLEED to SHUT. The APU air enters the duct on the engine one side, so engine bleed valve one closes as usual. But the APU cannot reach the engine two side through a shut crossbleed valve, so engine bleed valve two remains open, and engine two feeds pack two. The reference states this explicitly, and it is a lovely interview question, because it shows you understand why the valves close, not just when.
Part 3 · Leak detection
Leak detection loops X BLEED valve ENG 1 bleed IP / HP stages ENG 2 bleed IP / HP stages APU load compressor HP ground connection Wing anti-ice PACK 1 Cargo heating* Hyd reservoirs + water tank PACK 2 Wing anti-ice FTIS* engine starting engine starting * where installed (cargo heating, fuel tank inerting) Controlled by BMC 1 + BMC 2, the overhead panel and the ECAM. Loops detect overheating near hot air ducts in the fuselage, pylons and wings . Wing: double . APU: single . Pylon: single (later aircraft: double ).
Chapter 28 · Pneumatic and Bleed Air
15
e-books by eatpl.in · © 2026 · Do not copy or distribute
A leaking hot air duct can damage the structure and wiring around it, so the A320 watches every hot duct. Leak detection loops, sensing elements tied together, detect overheating near the hot air ducts in the fuselage, the pylons and the wings. Along each wing there is a double loop, and a wing leak signal needs both loops to detect the leak, or one to detect it with the other inoperative: the same idea as the fire loops. The pylons have a single loop on earlier aircraft and a double loop on later ones. The APU duct, running forward from the tail, has a single loop. B M C one and B M C two each contain identical control logic for the system.
Part 3 · Leak logic
What does each leak close? Leak Bleed valve FAULT light X BLEED valve APU bleed valve Wing (L or R) that side closes ENG BLEED, that side closes* closes* if open and the leak is in the left wing Pylon (1 or 2) that side closes ENG BLEED, that engine closes* closes* if open and the leak is in pylon 1 APU duct — APU BLEED closes* closes *
* except during engine start . Wing and pylon leaks close the bleed valve on that side whenever they are detected.
Chapter 28 · Pneumatic and Bleed Air
16
e-books by eatpl.in · © 2026 · Do not copy or distribute
This table is the core of the leak logic. A wing leak closes the engine bleed valve on that side and lights the FAULT light on that side’s ENG BLEED pushbutton. It also closes the crossbleed valve, so the leak cannot be fed from the other side, and, if the APU bleed valve is open and the leak is in the left wing, it closes the APU bleed valve too. A pylon leak does the same for its own engine, with pylon one also closing the APU bleed valve. An APU leak closes the APU bleed valve, lights the FAULT light in the APU BLEED pushbutton and closes the crossbleed valve. Notice the footnote: the crossbleed and APU valve closures are inhibited during engine start, when the duct must stay open to deliver air to the starter.
Part 3 · Worked example
A left wing leak with APU bleed on Ground, APU BLEED ON, X BLEED AUTO, not during engine start Left wing leak: APU bleed valve closes (left side) X BLEED valve closes ENG 1 BLEED FAULT amber + ECAM cautionRight wing leak instead: APU valve stays open , X BLEED closes Left wing leak, APU bleed ON A I R A I R C O N D C O N D PACK 1 PACK 2 ENG 1 BLEED APU BLEED ENG 2 BLEED RAM AIR FAULT OFF FAULT OFF FAULT ON ON X BLEED SHUT AUTO OPEN APU bleed valve : closes (left wing leak)X BLEED valve : closesENG 1 bleed valve : closed; FAULT on ENG 1 BLEEDENG 2 bleed valve : opens again: APU valve closedNot during engine start. Left side has no bleed air: the ECAM procedure guides the crew.
Chapter 28 · Pneumatic and Bleed Air
17
e-books by eatpl.in · © 2026 · Do not copy or distribute
Let us work through one case. The aircraft is on the ground, the APU bleed is supplying both packs through the open crossbleed, and the engines are not being started. A leak is detected in the left wing. The B M C closes the APU bleed valve, because the leak is on the left side, it closes the crossbleed valve, and it keeps engine bleed valve one closed, lighting the amber FAULT on the ENG 1 BLEED pushbutton with an ECAM caution. Since the APU bleed valve is now closed, nothing stops engine bleed valve two from opening if engine two is running. Now change one thing: put the leak in the right wing. The APU bleed pushbutton logic keeps the APU valve open, because the leak is not on the left, but the crossbleed valve closes, so the APU feeds only the left side.
Part 3 · Failures
When one BMC fails Earlier aircraft Later aircraft The other BMC takes over monitoring control and monitoring ECAM warnings kept overpressure, overtemperature , wing leak overpressure, wing leak Lost on the failed side the FAULT light ; the bleed valve no longer closes automatically overtemperature protection ; the bleed valve no longer closes automatically Leak warnings lost ENG BLEED LEAK for that engine; APU BLEED LEAK if BMC 1 failedAPU BLEED LEAK if BMC 1 failed
The key loss: the failed side’s bleed valve will not close automatically . The crew may have to do it.
Chapter 28 · Pneumatic and Bleed Air
18
e-books by eatpl.in · © 2026 · Do not copy or distribute
What happens if one B M C fails? The adjacent computer takes over, but not completely. On earlier aircraft it takes over the monitoring, so the ECAM still warns of overpressure, overtemperature and wing leaks on the failed side. But the FAULT light on that side’s pushbutton is lost, and the bleed valve on that side no longer closes automatically. The ENG BLEED LEAK warning is lost for that engine, and if it is B M C one that failed, the APU BLEED LEAK warning is lost too. On later aircraft the other computer takes over control and monitoring, keeps the overpressure and wing leak warnings, but the overtemperature protection of the failed side is lost, and again its bleed valve does not close automatically. The practical lesson: with a B M C failed, you are the automatic closure.
Part 4 · Overhead panel
The bleed controls on the AIR COND panel A I R A I R C O N D C O N D PACK 1 PACK 2 ENG 1 BLEED APU BLEED ENG 2 BLEED RAM AIR FAULT OFF FAULT OFF FAULT ON ON X BLEED SHUT AUTO OPEN 1 2 3 4 1 ENG 1 BLEED pb FAULT amber · OFF white 2 APU BLEED pb FAULT amber · ON blue 3 X BLEED selector SHUT · AUTO · OPEN 4 ENG 2 BLEED pb FAULT amber · OFF white Normal flight: ENG BLEED pbs on (lights out), APU BLEED off, X BLEED at AUTO .
Chapter 28 · Pneumatic and Bleed Air
19
e-books by eatpl.in · © 2026 · Do not copy or distribute
The bleed controls live on the lower part of the AIR COND panel, under a green mimic line that shows the duct feeding pack one and pack two. From left to right: the ENG 1 BLEED pushbutton, with an amber FAULT light and a white OFF light; the RAM AIR pushbutton, which belongs to air conditioning; the APU BLEED pushbutton, with an amber FAULT light and a blue ON light; the X BLEED rotary selector, with SHUT, AUTO and OPEN; and the ENG 2 BLEED pushbutton. In normal flight the panel is dark: both engine bleeds are on with no lights, APU BLEED is off, and the crossbleed selector is at AUTO. Remember the Airbus philosophy: a dark panel means everything is normal, so any light you see is information.
Part 4 · ENG BLEED pb
ENG 1 / ENG 2 BLEED: when does the valve open? The bleed valve opens with the pb ON if… Earlier aircraft Later aircraft upstream pressure above… 8 psi 15 psi APU BLEED pb off, or APU bleed valve closed yes yes no onside wing or pylon leak; no overpressure or overtemperature yes yes ENG FIRE pb not released yes yes engine start valve closed yes yes at least one bleed consumer (pack or WAI) ON on that side, or on the other side with X BLEED open — yes OFF selected bleed valve + HP valve close; white OFF + fan air valve closes; white OFF
Chapter 28 · Pneumatic and Bleed Air
20
e-books by eatpl.in · © 2026 · Do not copy or distribute
With the ENG BLEED pushbutton on, the bleed valve opens only if every condition in this table is met. The upstream pressure must be above eight psi, or fifteen on later aircraft. The APU BLEED pushbutton must be off, or the APU bleed valve closed. There must be no leak in the wing or pylon on that side, and no overpressure or overtemperature. The ENG FIRE pushbutton must not have been released. And the engine start valve must be closed. Later aircraft add one more: there must be at least one bleed consumer, a pack or wing anti-ice, switched on on that side, or on the other side with the crossbleed open. Selecting OFF closes the bleed valve and the H P valve, plus the fan air valve on later aircraft, and shows a white OFF light.
Part 4 · ENG BLEED pb
ENG BLEED FAULT: what does it mean? Amber FAULT + ECAM caution if… Applies to overpressure downstream of the bleed valve all aircraft bleed air overheat all aircraft wing or pylon leak on that sideall aircraft bleed valve not closed during engine start all aircraft bleed valve not closed with APU bleed ON all aircraft HP valve failed open on ground · single BTS failure or BTS disagree on ground · dual BTS failure later aircraft fan duct burst detected by the FADEC later aircraft, LEAP-1A engines
The FAULT light goes out when the pb is selected OFF , if the fault has disappeared .
Chapter 28 · Pneumatic and Bleed Air
21
e-books by eatpl.in · © 2026 · Do not copy or distribute
The amber FAULT light in an ENG BLEED pushbutton comes with an ECAM caution, and it has a short list of causes. Overpressure downstream of the bleed valve. A bleed air overheat. A wing or pylon leak on that side. The bleed valve not closed during an engine start, when it should be. And the bleed valve not closed with APU bleed on. Later aircraft add some sensor and valve failures, such as an H P valve failed open on the ground or failures of the bleed temperature sensors, and, on LEAP-1A engines, a fan duct burst detected by the FADEC. The FAULT light goes out when you select the pushbutton OFF, but only if the fault has disappeared. So a FAULT that stays on with the pushbutton off tells you the problem is still there, for example a leak.
Part 4 · APU BLEED pb
The APU BLEED pushbutton ON (blue): valve opens if APU speed above 95 % and no leak in the APU or the left side bleedA right-side leak: the X BLEED valve closes instead Off : the APU bleed valve closesFAULT (amber) + ECAM caution: APU leak Memo APU BLEED (green): APU available and pb ON APU BLEED FAULT ON Off APU bleed valve closes APU BLEED FAULT ON ON (blue) valve opens if N > 95 % and no APU or APU BLEED FAULT ON FAULT (amber) APU leak detected · ECAM caution left-side leak (right-side leak: X BLEED shuts) APU BLEED green memo: APU available and APU BLEED pb ON
Chapter 28 · Pneumatic and Bleed Air
22
e-books by eatpl.in · © 2026 · Do not copy or distribute
The APU BLEED pushbutton has three states. Selected ON, it shows a blue light, and the APU bleed valve opens provided the APU speed is above ninety-five per cent and there is no leak in the APU or in the left side bleed. If the leak is on the right side, the APU valve can stay open, but the crossbleed valve closes, keeping the APU air on the left. Off, the APU bleed valve closes. FAULT, in amber with an ECAM caution, means an APU leak has been detected. On the memo, APU BLEED appears in green when the APU is available and the pushbutton is ON, a useful reminder before take-off, because with APU bleed on the engine bleed valves stay closed.
Part 4 · ECAM
The ECAM BLEED page BLEED 24 °C C H 50 °C LO HI 25 °C C H 230 °C LO HI RAM AIR ANTI ICE ANTI ICE APU 44 180 PSI °C 1 IP HP 44 180 PSI °C 2 IP HP TAT +12 °C SAT -6 °C 10 H 42 GW 64300 KG 1 2 3 4 5 6 1 Precooler inlet pressure green · amber < 4 psi or overpressure 2 Engine bleed valve green: as commanded · amber: disagree 3 HP valve normally closed · amber: not as commanded 4 APU bleed valve shown with the APU MASTER sw ON 5 X BLEED valve green: as commanded · amber: disagree, transit 6 ANTI ICE + arrow WING pb ON · arrow green: valve open Shown in cruise with wing anti-ice ON and the APU master switch ON: bleed valves open , HP valves closed , X BLEED shut , all green .
Chapter 28 · Pneumatic and Bleed Air
23
e-books by eatpl.in · © 2026 · Do not copy or distribute
Here is the lower half of the ECAM BLEED page, the part that belongs to the pneumatic system. Under each side of the duct, a box shows the precooler inlet pressure in psi and the precooler outlet temperature in degrees. Below it, the engine bleed valve with the engine number, then the line down to the I P and H P ports, with the H P valve on a horizontal line. In the centre, the APU bleed valve, shown when the APU master switch is on, and to its right the crossbleed valve on the duct. When the WING pushbutton is on, the ANTI ICE legends and arrows appear at each end of the duct. In a normal cruise, both engine bleed valves are open, the H P valves closed, the crossbleed shut and everything green.
Part 4 · ECAM
Reading the BLEED page symbols HP valve normal: closed not fully closed not as commanded ENG bleed valve normal: open normal: closed disagree (open) APU bleed valve not fully open fully open shut, APU BLEED ON > 10 s X BLEED valve normal: closed normal: open in transit Other symbols arrow: WAI valve open amber: pressure low/high, or open on ground > 10 s 1 engine running 1 N2 below idle GND HP ground air can be connected (ground only) Green = normal for the command · Amber = position disagrees with the command, or abnormal A valve symbol is in line with the duct when open, across it when closed. Amber = not where it was commanded.
Chapter 28 · Pneumatic and Bleed Air
24
e-books by eatpl.in · © 2026 · Do not copy or distribute
The BLEED page uses one symbol language. A valve is a circle with a bar: in line with the duct when open, across it when closed. Green means the valve is where the system commanded it; amber means it is not. For the H P valve, closed is normal; in line means not fully closed, which you will see at low engine power; amber means it is not in its commanded closed position. The engine bleed valves are green open or green closed when they agree with the command, and amber when they disagree. The APU valve turns amber if it is still closed more than ten seconds after you selected APU BLEED on. The crossbleed shows a diagonal bar in amber while it is travelling. The engine number is white when the engine runs and amber when N two is below idle, and GND appears only on the ground, when high-pressure ground air can be connected.
Part 4 · ECAM limits
When do the numbers turn amber? Precooler inlet pressure amber: below 4 psi , or BMC overpressure (57–60 psi) Outlet overheat : > 290 °C for 5 s , > 270 °C for 15 s , > 257 °C for 55 s Low temperature (flight only): below 150 °C with WAI on and the regulating valve openAt idle on a cold day, below 150 °C may show amber normally The anti-ice arrow : amber if pressure low or high, or open on the ground > 10 s Precooler outlet temperature: amber 0 10 20 30 40 50 60 70 150 170 190 210 230 250 270 290 310 OVERHEAT (amber) regulated ≈ 200 °C < 150 °C in flight with WAI on: LOW (amber) 275 °C for 20 s 260 °C for 40 s time above the temperature (s) °C Overheat: > 290 °C for 5 s, > 270 °C for 15 s or > 257 °C for 55 s. At idle a low reading can be normal on a cold day.
Chapter 28 · Pneumatic and Bleed Air
25
e-books by eatpl.in · © 2026 · Do not copy or distribute
The two numbers in each engine box have limits. The precooler inlet pressure is green, and turns amber below four psi, or when the B M C detects overpressure, with a threshold between fifty-seven and sixty psi. The precooler outlet temperature is green, and turns amber for an overheat or a low temperature. Overheat uses a time and temperature rule: above two hundred and ninety degrees for more than five seconds, above two hundred and seventy for more than fifteen seconds, or above two hundred and fifty-seven for more than fifty-five seconds. So two hundred and seventy-five degrees for twenty seconds is an overheat, but two hundred and sixty for forty seconds is not yet. Low temperature, in flight only, is below one hundred and fifty degrees with wing anti-ice on and the regulating valve open, and at idle on a cold day it can be quite normal.
Exam traps
Six things candidates get wrong IP is normal, HP is the exception Air comes from the IP stage to save fuel; HP only at low engine speed .
APU BLEED closes the engine bleeds …and opens X BLEED in AUTO. With X BLEED SHUT , bleed valve 2 stays open .
Left side is special The APU valve closes for a left wing or pylon 1 leak, not for a right-side leak.
Engine start inhibits X BLEED and APU valve leak closures are inhibited during engine start .
Overpressure valve = 75 psi The PRV holds 45 ± 5 psi ; the separate OPV closes only if regulation fails, above 75 psi .
BMC failure The other BMC monitors, but the failed side’s bleed valve does not close automatically .
Chapter 28 · Pneumatic and Bleed Air
26
e-books by eatpl.in · © 2026 · Do not copy or distribute
Six traps before we finish. One: the normal source is the intermediate pressure stage; the high pressure stage is only used when the engine is slow. Two: selecting APU bleed on closes the engine bleed valves and, in AUTO, opens the crossbleed, but with the crossbleed shut, engine bleed valve two stays open. Three: the left side is special, because a left wing or pylon one leak also closes the APU bleed valve. Four: during engine start, the leak closures of the crossbleed and APU valves are inhibited, so the starter keeps its air. Five: the bleed valve regulates around forty-five psi, and the separate overpressure valve only closes above seventy-five psi if regulation fails. Six: after a B M C failure the other computer monitors, but the failed side’s bleed valve no longer closes by itself.
Summary
The pneumatic system on one page Sources and users Engine bleed , APU , HP ground → crossbleed duct → packs, start, WAI, reservoirs, water (+ cargo heat, FTIS).
Selection IP normally; HP valve at low speed (36 ± 4 / 65 ± 15 psi); IP check valve stops back-flow.
Pressure and temperature Bleed valve 45 ± 5 psi (later 42 / 50); OPV 75 psi ; precooler ≈ 200 °C with the fan air valve.
APU and crossbleed APU BLEED ON (> 95 %): APU valve opens, X BLEED opens (AUTO), engine bleeds close. Two-motor X BLEED valve.
Leaks and BMCs Wing double loop, APU single , pylon single / double. Leak: close that side, X BLEED, APU (left). BMC fail: no auto-close.
Cockpit ENG BLEED FAULT / OFF, APU BLEED FAULT / ON, X BLEED SHUT / AUTO / OPEN. BLEED page: green = as commanded.
Chapter 28 · Pneumatic and Bleed Air
27
e-books by eatpl.in · © 2026 · Do not copy or distribute
To sum up. High-pressure air comes from the engines, the APU or a ground cart, meets in the crossbleed duct and goes to the packs, the starters, wing anti-ice and the reservoirs. Each engine normally bleeds from the intermediate stage, switching to the high pressure stage when slow. The bleed valve regulates the pressure, the overpressure valve protects against a regulation failure, and the precooler, with its fan air valve, brings the air to about two hundred degrees. Selecting APU bleed opens the crossbleed in AUTO and closes the engine bleeds. Leak loops along the wings, pylons and APU duct let the B M Cs close the right valves, and a failed B M C means you take over the closing. On the panel and the ECAM, dark and green mean normal. Well done.