A320 Aircraft Systems · Chapter 32
Power Plant: Engine, FADEC and Thrust Levers How the A320's high-bypass turbofans are built, how the FADEC runs them, and how the thrust levers, detents and rating limits turn your hand movement into thrust.
ACCESSORY GEARBOX 5 10 85. 3 735 5 10 85. 3 742 N1 % EGT °C N2 % FF KG/H 95. 1 2580 95. 2 2600 FLX 85.3 % 58°C © 2026 eatpl.in. For the personal study of eatpl.in students only. Do not copy or distribute.
e-books by eatpl.in · © 2026 · Do not copy or distribute
Welcome to the power plant. Every other system we have studied so far, the hydraulics, the electrics, the air conditioning, ultimately takes its energy from two engines hanging under the wings. In this lesson we open one up. We will see how air goes through the fan and the core, why N1 and N2 matter, and what the accessory gearbox drives. Then we meet the FADEC, the computer that has full authority over each engine, and learn its idle modes. After that, the part you will use on every single flight: the thrust levers, their detents, the rating limits and flex take-off. We finish inside the engine again with its fuel, oil and air systems. Two engine types are covered, the CFM56 and the LEAP, and we will point out where they differ.
Power plant
Our route through ATA 70, part one ACCESSORY GEARBOX TO/GA FLX/MCT CL IDLE (0) REV IDLE MAX REV The engine Two spools, N1 and N2, the combustion chamber and the accessory gearbox.
FADEC Two channels, power supply, inputs and outputs, functions and the three idle modes.
Thrust levers Stops and detents, rating limits, FLX/MCT, manual and automatic thrust.
Engine systems Fuel and HMU, variable geometry, IDG fuel cooling, oil and air bleed.
Chapter 32 · Power Plant: Engine, FADEC and Thrust Levers
2
e-books by eatpl.in · © 2026 · Do not copy or distribute
Here is our route through the first half of chapter seventy, the power plant. We start with the engine itself: how air flows through it, what N1 and N2 are, and what hangs on the accessory gearbox. Then the FADEC, the full authority digital engine control, including its two channels, its power supply, its inputs and outputs, and the three idle modes. Third, and most practical, the thrust levers: their stops and detents, the thrust rating limit for each lever position, the flex take-off logic and manual versus automatic thrust. Finally we go back inside the engine for its fuel, oil and air systems. Starting, ignition, reversers and the cockpit indications are in the next lesson.
Part 1 · The engine
Two high-bypass turbofans Two wing-mounted turbofan engines with a high bypass ratio Depending on the aircraft: CFM56-5B or LEAP-1A Each has its own FADEC , fuel, oil and air systems Plus a thrust reverser , an ignition system and a start system Engine 1 on the left wing, engine 2 on the right ENG 1 ENG 2 CFM56-5B or LEAP-1A, depending on the aircraft
Chapter 32 · Power Plant: Engine, FADEC and Thrust Levers
3
e-books by eatpl.in · © 2026 · Do not copy or distribute
The A320 family has two engines, one under each wing, and both are turbofans with a high bypass ratio. You will meet two engine types: the CFM fifty six five B on the older aircraft, and the LEAP one A on the newer ones. Watch the nacelles light up. Each engine is a complete package: it has its own full authority digital engine control, its own fuel, oil and air systems, a thrust reverser, an ignition system and a start system. The engines also feed the aircraft. Fuel comes in from the wing tanks, and compressed bleed air goes out to the pneumatic system, which feeds the air conditioning. Engine one is always the left engine and engine two the right one.
How it works
Fan, core, N1 and N2 The LP compressor (the fan plus booster stages) compresses the air Most of it bypasses the core and gives most of the thrust The rest enters the core: HP compressor , combustion chamber , then the HP and LP turbines N1 = fan (LP rotor) speed, N2 = HP rotor speed, both in per cent, on the E/WDThe FADEC uses N1 to set thrust , and N1 and N2 for control and monitoring ACCESSORY GEARBOX bypass air: most of the thrust FAN (N1) LP COMPRESSOR HP COMPRESSOR (N2) COMBUSTION CHAMBER HP TURBINE LP TURBINE green: LP shaft (fan + LP compressor to LP turbine) · blue: HP shaft
Chapter 32 · Power Plant: Engine, FADEC and Thrust Levers
4
e-books by eatpl.in · © 2026 · Do not copy or distribute
Let us follow the air through the engine. First the fan, which is the front part of the low pressure compressor, compresses the incoming air. Then the flow splits. Most of the air goes round the outside as bypass air, and it is this cold bypass stream that produces most of the thrust. The rest goes into the core, where the high pressure compressor squeezes it further. Fuel is added and the mixture is ignited in the combustion chamber. The hot gas then drives two turbines: the high pressure turbine, which turns the high pressure compressor, and the low pressure turbine, which turns the fan. The fan speed is called N1 and the high pressure rotor speed is N2, both shown in per cent on the engine display. The FADEC uses N1 as its thrust-setting parameter.
Two engine types
CFM56-5B and LEAP-1A compared CFM56-5B LEAP-1A LP compressor / LP turbine fan + 4 stages / 4 stages fan + 3 stages / 7 stages HP compressor / HP turbine 9 stages / 1 stage 10 stages / 2 stages Fuel control HMU (hydromechanical unit) FMU + SCU/SVA Thrust reverser 4 pivoting blocker doors translating sleeves and cascades
Chapter 32 · Power Plant: Engine, FADEC and Thrust Levers
5
e-books by eatpl.in · © 2026 · Do not copy or distribute
Both engine types have the same architecture: two compressor and turbine assemblies, each joined by its own shaft. The low pressure shaft joins the fan and LP compressor to the LP turbine, and the high pressure shaft joins the HP compressor to the HP turbine. Both have an annular combustion chamber with fuel nozzles and two igniters. The differences are in the stage counts, which are popular interview questions. The CFM fifty six has a fan plus four booster stages, a four stage LP turbine, a nine stage HP compressor and a single stage HP turbine. The LEAP has a fan plus three, a seven stage LP turbine, ten HP compressor stages and two HP turbine stages. The fuel control and the reverser are also different, and we will meet both.
Accessory gearbox
What the gearbox drives Driven by the HP shaft , so everything on it turns with N2 Oil feed pump and main engine fuel pump Engine-driven hydraulic pump : green on engine 1, yellow on engine 2IDG : the primary source of electrical powerFADEC alternator and the pneumatic starter HP SHAFT (N2) core of the engine radial drive ACCESSORY GEARBOX OIL FEED PUMP lubrication MAIN FUEL PUMP to the burners HYD PUMP G (1) · Y (2) green or yellow IDG GENERATOR main AC power FADEC ALTERNATOR powers the FADEC PNEUMATIC STARTER turns the engine Everything on the gearbox turns with N2 engine stopped = no engine pump, no IDG, no FADEC alternator
Chapter 32 · Power Plant: Engine, FADEC and Thrust Levers
6
e-books by eatpl.in · © 2026 · Do not copy or distribute
The accessory gearbox takes mechanical power from the high pressure shaft, through a radial drive, and uses it to turn the accessories that the engine and the aircraft need. So everything on the gearbox turns at a speed proportional to N2. There are six to remember. The oil feed pump, which supplies the engine oil system. The main engine fuel pump, which feeds the combustion chamber. The engine-driven hydraulic pump, green on engine one and yellow on engine two. The integrated drive generator, which is the primary source of electrical power. The FADEC alternator, which powers the FADEC itself. And the pneumatic starter, which turns the gearbox, and therefore the HP rotor, to start the engine. No N2 means none of these work.
Part 2 · FADEC
Full Authority Digital Engine Control One FADEC per engine, mounted on the fan case ; complete engine management Two channels : one active, one in standbyIf the active channel fails, the other takes over automatically Own magnetic alternator as an internal power source The EIU (engine interface unit) passes it the aircraft data it needs FAN CASE (engine 1) FADEC CHANNEL A ACTIVE controls CHANNEL B STANDBY ready one fails: the other takes control automatically ALT magnetic alternator EIU engine interface unit aircraft data
Chapter 32 · Power Plant: Engine, FADEC and Thrust Levers
7
e-books by eatpl.in · © 2026 · Do not copy or distribute
Each power plant has its own FADEC, a full authority digital engine control. Full authority means exactly that: it performs complete engine management, from the start to the shutdown. To make that safe, each FADEC has two channels. One is active and the other is in standby, and if the active channel fails, the standby channel takes control automatically. The FADEC sits on the fan case, and it has its own magnetic alternator as an internal power source, so once the engine is turning it does not depend on the aircraft electrical system. The aircraft talks to it through the engine interface unit, the E I U, which sends the FADEC the aircraft data it needs.
FADEC one per engine, 2 channels engine sensors in Thrust lever angle TLA, from each thrust lever ADIRS air data EIU (engine interface unit) ENG MASTER · MODE · MAN START ACSC (bleed demand) LGCIU (ground / flight) ENG ANTI ICE pb FMGS (A/THR) thrust demand Ignition system Fuel return valve Start valve Thrust reverser system Cooling and stability control ECAM: E/WD and SD engine parameters, status FADEC commands The EIU collects cockpit switch positions and aircraft system data; the FADEC drives the engine and reports to the ECAM.
Chapter 32 · Power Plant: Engine, FADEC and Thrust Levers
8
e-books by eatpl.in · © 2026 · Do not copy or distribute
Here is the FADEC in its surroundings. On the input side, it reads the thrust lever angle directly, and it gets air data from the air data and inertial reference system. Most other aircraft information arrives through the engine interface unit: the positions of the ENG MASTER lever, the mode selector and the manual start button, the bleed demand from the air conditioning controller, ground or flight from the landing gear computers, and the engine anti-ice button. The flight guidance computers send the autothrust demand. On the output side, the FADEC commands the ignition system, the fuel return valve, the start valve, the thrust reverser system, and the engine cooling and stability devices. And it sends all the engine parameters and status to the engine warning display and the system display.
Gas generator Fuel flow, acceleration and deceleration schedules, VBV and VSV, turbine clearance, idle setting.
Limit protection N1 and N2 overspeed; EGT monitoring during the start (LEAP: EGT limits in the automatic start).
Power management Rating limits, thrust parameter limits, manual thrust from the lever, A/THR demand.
Starting Automatic start: start valve, HP fuel valve, fuel flow, ignition; abort and recycle on the ground (LEAP: starter time limit).
Manual start Passive monitoring; controls the start valve, HP fuel valve and ignition.
Reverser and fuel Reverser actuation and engine setting in reverse; fuel recirculation to the tanks.
Indications Engine parameters, start, reverser and FADEC status to the ECAM; failure detection and recording.
LEAP-1A adds Stall and flame-out protection, TCMA, bowed rotor protection, vibration monitoring.
Chapter 32 · Power Plant: Engine, FADEC and Thrust Levers
9
e-books by eatpl.in · © 2026 · Do not copy or distribute
The FADEC has a long job list, so let us group it. First, it controls the gas generator: fuel flow, the acceleration and deceleration schedules, the variable bleed valves and variable stator vanes, turbine clearance and the idle setting. Second, it protects the engine against N1 and N2 overspeed, and watches the E G T during the start. Third, power management: it computes the rating limits and sets thrust from the lever in manual, or from the autothrust demand. Fourth, it runs the automatic start, with abort and recycle on the ground, and it supports a manual start. It also controls the reverser and fuel recirculation, sends everything to the ECAM, and detects and records failures. The LEAP FADEC adds stall and flame-out protection, thrust control malfunction accommodation and bowed rotor protection.
FADEC power
Powering the FADEC Normally: the FADEC alternator or, automatically, the aircraft network Engine stopped: no alternator output, so the aircraft network is used ENG FADEC GND PWR pb (maintenance panel), one per engineON, on the ground: aircraft network supplies the FADEC, if the ENG FIRE pb is not pressed and the alternator is not supplying it ENG FADEC GND PWR 1 ON 2 ON maintenance panel (overhead) pb not pressed FADEC alternator, or the aircraft network, automatically ON (ground) aircraft network supplies the FADEC, if both: ENG FIRE pb not pressed FADEC alternator not supplying the FADEC Ground use with the engine stopped (no alternator output)
Chapter 32 · Power Plant: Engine, FADEC and Thrust Levers
10
e-books by eatpl.in · © 2026 · Do not copy or distribute
Where does the FADEC get its electricity? Once the engine is turning fast enough, from its own alternator on the gearbox. Before that, for example during the start, the aircraft electrical network supplies it automatically. On the ground with the engine stopped, the maintenance crew sometimes needs the FADEC powered to check it. For that there are two ENG FADEC GND PWR buttons on the maintenance panel in the overhead, one per engine. With the button pressed on, on the ground, the aircraft network supplies the FADEC, provided two conditions are met: the ENG FIRE pushbutton for that engine has not been pressed, and the FADEC alternator is not already supplying it. Released, the system simply goes back to the automatic choice between the alternator and the aircraft network.
FADEC idle control
Three idle modes Idle mode CFM56-5B LEAP-1A Regulated by Modulated (CFM) / minimum (LEAP) In flight with the FLAPS lever at 0; on the ground unless reverse is selected In flight with the gear up and not CONF 3 or FULL; on the ground unless reverse is selected Bleed demand and ambient conditions Approach idle In flight with the FLAPS lever not at 0 In flight in CONF 3 or FULL, or with the gear down Aircraft altitude (CFM: regardless of bleed; LEAP: also bleed and ambient) Reverse idle On the ground with the lever at REV IDLE On the ground with the lever at REV IDLE Slightly higher than forward idle
Approach idle lets the engine accelerate quickly from idle to go-around thrust. Trap: a LEAP aircraft in CONF 1 or 2 with the gear up is still at minimum idle.
Chapter 32 · Power Plant: Engine, FADEC and Thrust Levers
11
e-books by eatpl.in · © 2026 · Do not copy or distribute
The FADEC chooses between three idle levels. The lowest is called modulated idle on the CFM engine and minimum idle on the LEAP. It varies with bleed demand and ambient conditions, and it is used in flight when the aircraft is clean, and on the ground whenever reverse is not selected. Approach idle is higher, and it exists so that the engine can accelerate quickly from idle to go-around thrust. On the CFM, approach idle comes in as soon as the flaps lever leaves zero. On the LEAP the condition is different: CONF three or FULL, or the landing gear down. So a LEAP aircraft in CONF one or two with the gear up is still at minimum idle, which is a classic trap. Finally reverse idle, selected on the ground with the levers at REV IDLE, is slightly higher than forward idle.
Part 3 · Thrust levers
Stops, detents and segments TO/GA FLX/MCT CL IDLE (0) REV IDLE MAX REV 1 2 3 4 Six positions, four segments 3 stops (red) TO/GA · IDLE (0) · MAX REV 3 detents (blue) FLX/MCT · CL · REV IDLE 4 segments 1 TO/GA–FLX/MCT · 2 FLX/MCT–CL 3 CL–IDLE · 4 reverse Moved by hand only one lever per engine The FADEC reads each lever position and computes the thrust rating limit and the N1 for that lever angle.
Chapter 32 · Power Plant: Engine, FADEC and Thrust Levers
12
e-books by eatpl.in · © 2026 · Do not copy or distribute
Now the thrust levers. They are moved by hand only. Unlike some other airliners, the autothrust never moves them. Each lever travels over a sector with six positions. Three are stops, which the lever cannot go past: TO GA at the front, IDLE, marked zero, and MAX REV at the back. Three are detents, which the lever clicks into: FLX MCT, CL and REV IDLE. Between them lie four operating segments: from TO GA to FLX MCT, from FLX MCT to CL, from CL back to IDLE, and the reverse segment behind idle. The FADEC reads the lever position, which we call the thrust lever angle, and from it computes two things: the thrust rating limit, and the N1 that corresponds to that lever angle. Both are displayed for you on the engine display.
Thrust rating limit
The rating limit for each lever position In a detent: the rating of that detent Between two detents: the rating of the higher detent In flight, or engine not running: CL , MCT or FLX , TOGA , MREV On the ground, engine running: FLX from idle to FLX/MCT, TOGA above it Inputs: lever position, ground or flight, engine running, MCDU PERF T.O and CLB data TO/GA FLX/MCT CL IDLE (0) REV IDLE MAX REV TOGA MCT/FLX CL MREV TOGA FLX MREV Outer ring: in flight, or on the ground with engine not running Inner ring: on the ground with the engine running Between two detents, the higher detent counts
Chapter 32 · Power Plant: Engine, FADEC and Thrust Levers
13
e-books by eatpl.in · © 2026 · Do not copy or distribute
For every lever position the FADEC picks a thrust rating limit. If the lever is in a detent, it uses that detent's rating. If it is between two detents, it uses the rating of the higher one. So a lever halfway between CL and FLX MCT gives you the MCT or FLX limit, not climb. The picture shows the two cases. In flight, or on the ground with the engine not running, the outer ring applies: climb from idle up to CL, MCT or FLX up to the FLX MCT detent, TOGA above it, and maximum reverse behind idle. On the ground with the engine running, the inner ring applies: anywhere from idle up to FLX MCT the limit is FLX, above that TOGA. The data entered in the take-off and climb panels of the MCDU performance pages feed these limits too.
On the E/WD
Thrust rating mode and limit Mode in cyan : TOGA, MCT, CLB, FLX, MREV ; on some aircraft D04, D08… (derated) and GA SOFT N1 limit value in green next to it FLX : flex temperature from the MCDU PERF T.O page shown in cyanCFM: cyan dashes if SAT is above the flex temperature Limit value disappears when the reversers are selected Upper right corner of the E/WD FLX 85.3 % 58°C flex take-off flex temperature 58 FLX 85.3 % - - °C CFM: SAT above the flex temperature TOGA 95.6 % take-off / go-around CLB 89.0 % climb MCT 93.1 % maximum continuous MREV max reverse limit value hidden D04 91.2 % derated take-off (some aircraft) GA SOFT 86.0 % soft go-around (some aircraft)
Chapter 32 · Power Plant: Engine, FADEC and Thrust Levers
14
e-books by eatpl.in · © 2026 · Do not copy or distribute
The rating the FADEC has chosen is shown in the top right corner of the engine and warning display. The mode is in cyan: TOGA for take-off or go-around, MCT, CLB for climb, FLX for flex take-off, and MREV for maximum reverse. Some aircraft also have derated take-off modes, D zero four, D zero eight and so on, and a soft go-around mode called GA SOFT. Next to the mode, in green, is the N1 limit value for that rating. In FLX the flex temperature that you entered on the take-off performance page appears underneath in cyan. On the CFM aircraft, if the static air temperature is above the flex temperature, you see cyan dashes instead. The thrust limit value disappears when the reversers are selected.
Thrust control
Manual mode Manual when A/THR is not armed , or armed but not active (lever outside the A/THR range, no alpha floor) Each engine is controlled by its own lever , between IDLE and TOGA Every lever position corresponds to an N1 In a detent, N1 = the rating limit N1 for that detent The blue circle on the N1 gauge shows the lever position 20 40 60 80 100 N1 % IDLE CL FLX/MCT TO/GA thrust lever position 89.0 93.1 95.6 FLX 85.3 on the ground between detents: proportional N1 Manual mode: lever position = N1 (example values)
Chapter 32 · Power Plant: Engine, FADEC and Thrust Levers
15
e-books by eatpl.in · © 2026 · Do not copy or distribute
In manual mode the pilot sets the thrust directly with the levers. The engines are in manual mode when autothrust is not armed, or when it is armed but not active, meaning the levers are outside the autothrust range and alpha floor has not triggered. Each engine is then controlled by its own lever, anywhere between IDLE and TOGA, and each lever position corresponds to an N1. When you place a lever in a detent, the commanded N1 is exactly the rating limit the FADEC has computed for that detent. Watch the lever. At idle the N1 is low. Move it to the climb detent and N1 goes to the climb rating, in this example eighty nine per cent. In flight, the flex detent gives maximum continuous, here ninety three point one, and TOGA gives ninety five point six.
FLX/MCT detent
FLX or MCT? On the ground: FLX if a flex temperature above TAT was entered on the MCDU, otherwise MCT After take-off: to change FLX to MCT, move the lever to TOGA or CL , then back to MCT After that, FLX can no longer be used Lever out of the detent without reaching TOGA or CL: no effect TOGA always gives maximum take-off thrustLever in FLX/MCT On the ground? yes Flex temperature entered on the MCDU and above TAT? yes no FLX MCT no (in flight) After take-off FLX → MCT: move the lever to TOGA or CL, then back to MCT From then on the FLX rating cannot be used again Lever moved out of the detent without reaching TOGA or CL: no effect
Chapter 32 · Power Plant: Engine, FADEC and Thrust Levers
16
e-books by eatpl.in · © 2026 · Do not copy or distribute
The FLX MCT detent does two jobs, so the FADEC needs a rule. On the ground, the engine runs at the flex take-off rating if you have entered a flex temperature on the MCDU that is higher than the current total air temperature. Otherwise you get maximum continuous thrust. After take-off, while the lever is still in that detent, the engine stays at flex. To change from flex to MCT, for example after an engine failure, you move the lever to TOGA or to CL, and then back to the MCT detent. From that moment on the flex rating is gone and cannot be used again. Be careful: if you nudge the lever out of the detent and back without reaching TOGA or CL, nothing changes. And remember, TOGA always gives you full take-off thrust.
Worked examples
Which rating do I get? 1 · Flex 58 °C, TAT 24 °C Lever to FLX/MCT on the runway: 58 is above 24, so the E/WD shows FLX with 58 °C in cyan.
2 · Flex 20 °C, TAT 31 °C Flex temperature below TAT: the FADEC gives MCT , not flex.
3 · Lever between CL and FLX In flight: the higher detent counts, so the rating is MCT (FLX if still in the flex take-off).
4 · Engine failure at 400 ft Lever stays at FLX/MCT: still FLX . Moved to TOGA and back: MCT , and FLX is gone.
5 · Lever nudged forward Out of FLX/MCT and back, not reaching TOGA or CL: no change .
6 · Normal climb At thrust reduction altitude the levers go to CL: CLB appears.
Chapter 32 · Power Plant: Engine, FADEC and Thrust Levers
17
e-books by eatpl.in · © 2026 · Do not copy or distribute
Let us practise. One: flex temperature fifty eight, total air temperature twenty four. Fifty eight is higher, so with the levers in FLX MCT on the runway you get FLX, and fifty eight degrees appears in cyan. Two: flex twenty, TAT thirty one. The flex temperature is below TAT, so the FADEC gives MCT instead. Three: in flight, a lever left between CL and FLX MCT gets the higher detent's rating, MCT. Four: an engine fails at four hundred feet after a flex take-off. If you leave the lever where it is, you are still at flex. Move it to TOGA and back, and you now have MCT, but flex is gone for good. Five: a lever nudged out of the detent and back without reaching TOGA or CL changes nothing. Six: at thrust reduction the levers go to CL and the climb rating appears.
Thrust control
Automatic mode and go-around A/THR active: the FMGC computes the thrust , limited by the lever position (unless alpha floor ) A/THR operating range: IDLE to CL with two engines, IDLE to MCT with one Go-around: levers at TOGA → TOGA thrust Some aircraft, soft go-around: TOGA then FLX/MCT → thrust for about 2 300 ft/min , or TOGA if that cannot be reached The FADECs watch the lever positions and trigger the FMA indications TO/GA FLX/MCT CL IDLE (0) REV IDLE MAX REV A/THR active range 2 engines: IDLE to CL 1 engine: IDLE to MCT A/THR active: the FMGC computes the thrust never above the lever detent limit (unless alpha floor) TOGA always gives maximum take-off thrust
Chapter 32 · Power Plant: Engine, FADEC and Thrust Levers
18
e-books by eatpl.in · © 2026 · Do not copy or distribute
In automatic mode the autothrust is active and the flight management and guidance computer calculates the thrust. But the FADEC still enforces the lever: the thrust can never exceed the limit of the detent the lever is in, unless alpha floor has been triggered. In normal operation with both engines, the autothrust works with the levers anywhere between idle and the climb detent; with one engine inoperative its range extends up to MCT. In a go-around, levers to TOGA give TOGA thrust. On aircraft with soft go-around, if you go to TOGA and then bring the levers back to FLX MCT, the autothrust targets a vertical speed of about two thousand three hundred feet per minute, or TOGA thrust if it cannot reach that. The FADECs also tell the flight mode annunciator what the levers are doing.
Pedestal
Reverse levers and the A/THR pb Each thrust lever has a reverse lever that unlocks reverse It can be lifted only when its thrust lever is at the IDLE (0) stop Lifted: the thrust lever can go aft of idle ; at REV IDLE it cannot stay at idle It relocks automatically when the thrust lever goes forward of idle Red A/THR instinctive disconnect pb on each lever TO GA FLX MCT CL 0 REV FULL A/THR instinctive disconnect pb reverse lever (in front of the thrust lever) Lift the reverse lever only at the IDLE (0) stop Lifted: lever can go aft into REV IDLE … FULL Forward of idle: relocks Forward of IDLE only when the reverse lever is locked
Chapter 32 · Power Plant: Engine, FADEC and Thrust Levers
19
e-books by eatpl.in · © 2026 · Do not copy or distribute
Reverse thrust is protected by a mechanical interlock. Each thrust lever has a reverse lever in front of it. You can only pull the reverse lever up when the thrust lever is at the idle stop. Once it is up, in the unlocked position, the thrust lever can move aft of idle into the reverse segment. Pull it up to select reverse idle, and the lever can no longer stay in the forward idle position. Pull further for more reverse, up to the MAX REV stop. Going the other way, the thrust lever can only move forward of idle when the reverse lever is locked down, and the reverse lever relocks automatically when the thrust lever goes forward of idle. Finally, on the outside of each thrust lever is the red autothrust instinctive disconnect pushbutton, which disconnects the autothrust.
Part 4 · Engine fuel system
CFM56: from the tank to the nozzles WING TANK LP SOV LP PUMP FUEL/OIL HEAT EXCH. HP PUMP (gear) HMU metering HP SOV FUEL NOZZLES combustion chamber bypass valve: excess fuel back to the HP pump inlet filtered: servos + heater unfiltered: metering valve IDG oil cooling → FRV gearbox driven gearbox driven ENG MASTER OFF closes the LP and HP shut-off valves and the fuel return valve, and opens the bypass valve.
Chapter 32 · Power Plant: Engine, FADEC and Thrust Levers
20
e-books by eatpl.in · © 2026 · Do not copy or distribute
Now the engine fuel system, which must deliver fuel to the combustion chamber at the right flow, pressure and temperature. Follow the fuel from the tank. It passes the low pressure shut-off valve, then the LP pump, the boost stage of the fuel pump unit, which is driven through the gearbox. Next the fuel oil heat exchanger, where the cold fuel cools the engine oil. Then the HP pump, a gear pump, raises the pressure and feeds the hydromechanical unit, the H M U, which meters exactly the fuel the FADEC asks for. Metered fuel goes through the HP shut-off valve to the fuel nozzles. Fuel the HMU does not need goes back through the bypass to the pump. Now watch the ENG MASTER go OFF: the LP and HP shut-off valves close, the burners go out, and the bypass valve opens.
Hydromechanical unit
How the HMU meters fuel FADEC computes the fuel flow for the target N1 ; N2 is free between N2 min and N2 max Fuel metering valve : torque motor and servo valve; a resolver feeds back its positionBypass valve keeps a constant pressure drop, so flow ∝ valve positionLimits acceleration and deceleration, avoids stall and flame-out , limits N1 and N2, keeps bleed pressure Overspeed governor , independent of the FADEC, limits N2 by opening the bypassFADEC target N1 → fuel flow HMU order torque motor + servo valve FUEL METERING VALVE (FMV) from HP pump metered fuel to nozzles resolver position feedback BYPASS VALVE constant Δp across FMV OVERSPEED GOVERNOR independent: opens bypass flow ∝ valve position, because Δp is held constant excess fuel bypassed back to the pump inlet
Chapter 32 · Power Plant: Engine, FADEC and Thrust Levers
21
e-books by eatpl.in · © 2026 · Do not copy or distribute
The hydromechanical unit turns FADEC commands into fuel. The FADEC computes the fuel flow that will hold the target N1, and while doing so it lets N2 find its own value, as long as it stays between a minimum and a maximum. A torque motor and servo valve position the fuel metering valve, and a resolver feeds its position back to the FADEC. The bypass valve keeps the pressure drop across the metering valve constant, so the flow is simply proportional to the valve position. The FADEC also limits acceleration and deceleration, protects against stall and flame-out, limits N1 and N2, maintains the bleed pressure the aircraft needs, and corrects N2 for the bleed configuration. And as a back-up, an overspeed governor, independent of the FADEC, limits N2 by opening the bypass valve.
Fuel as a hydraulic fluid
Variable stator vanes and bleed valves The HMU sends fuel hydraulic signals to the engine actuators VSV : position the HP compressor vanes; fully closed at start , fully open at high thrustVBV (before the HP compressor): open at start, low thrust and fast deceleration ; closed at high thrustVBV setting depends on compressor inlet temperature and N2 Also: LP and HP turbine clearance control and rotor active clearance control valves VSV stator vanes (HP compressor) open closed start / low thrust high thrust VBV bleed valves (before the HPC) open closed start / low thrust high thrust VBVs also go fully open during a fast deceleration
Chapter 32 · Power Plant: Engine, FADEC and Thrust Levers
22
e-books by eatpl.in · © 2026 · Do not copy or distribute
Fuel under pressure is also used as a hydraulic fluid to move parts of the engine. The HMU sends these fuel hydraulic signals to several actuators. The variable stator vanes set the angle of the vanes in the HP compressor: the FADEC keeps the compressor efficient in steady running and keeps a good stall margin during transients. They are fully closed during the start and fully open at high thrust. The variable bleed valves sit upstream of the HP compressor and let air escape from the booster when the core cannot swallow it all. Their setting depends on compressor inlet temperature and N2: fully open at start, at low thrust and during a fast deceleration, and fully closed at high thrust. The same signals also drive the turbine and rotor clearance control valves.
IDG cooling (CFM56)
Fuel cools the IDG oil Some HMU fuel cools the IDG oil , then returns to the pump unit or to the tank The fuel return valve (FADEC) manages the flow: 300 kg/h to the tank, then higher min N2 , then up to 600 kg/h Returning fuel kept below 100 °C by mixing hot with cold FRV closed : shutdown, take-off and climb, wing tank below about 300 kg (280 kg on some aircraft), surge tank overflow, gravity feed, wing fuel above 52.5 °C in flight On the ground, hot wing fuel or surge tank overflow does not close it HMU fuel out IDG OIL COOLER FRV back to pump unit wing tank FADEC controls the FRV Hot IDG oil, low thrust 1 300 kg/h back to the tank 2 still rising: minimum N2 increased 3 still rising: 300 → 600 kg/h Returning fuel always mixed to stay below 100 °C (200 to 400 kg/h) FRV closed (inhibited) engine shutdown take-off and climb wing tank below ~300 kg surge tank overflow gravity feed only wing fuel above 52.5 °C in flight
Chapter 32 · Power Plant: Engine, FADEC and Thrust Levers
23
e-books by eatpl.in · © 2026 · Do not copy or distribute
The IDG, the generator on the gearbox, has its own oil, and that oil is cooled by engine fuel. Fuel from the HMU passes through the IDG oil cooler and then returns either to the pump unit or, through the fuel return valve, to the wing tank. The FADEC controls that valve. At low thrust, if the IDG oil is too hot, three hundred kilograms per hour go back to the tank. If it keeps rising, the minimum N2 is raised. If it still rises, the flow to the tank goes up to six hundred kilograms per hour. The valve mixes hot and cold fuel so the returning fuel stays below a hundred degrees. Recirculation is stopped at shutdown, during take-off and climb, with a low wing tank, surge tank overflow, gravity feeding, or wing fuel above fifty two point five degrees in flight.
LEAP-1A
The LEAP-1A fuel system Main fuel pump (gearbox driven): LP stage, then IDG oil cooling , then HP gear stage; bypass valve against overpressureMain fuel filter , fuel nozzles, fuel return valve , main fuel/oil heat exchanger FMU : fuel metering valve, HPSOV (closes against N2 overspeed) and the TCMA subsystemSCU/SVA : hydraulic power for VSV, VBV, turbine cooling and clearance, TBV, SB/BAI valveFMU and SCU/SVA are separate units that turn FADEC signals into hydraulic flow MAIN FUEL PUMP (MFP) driven by the gearbox LP stage HP stage (gear) IDG oil bypass valve on the MFP: protects against overpressure LP flow also goes to the fuel return valve (FRV) main fuel filter FUEL METERING UNIT FMV: fuel flow for thrust HPSOV: closes against N2 overspeed TCMA subsystem: trims the metered flow to nozzles SCU / SVA hydraulic power for: VSVs and VBVs modulated turbine cooling HPTACC and LPTACC transient bleed valve start bleed / booster anti-ice valve FMU and SCU/SVA turn FADEC signals into hydraulic flow
Chapter 32 · Power Plant: Engine, FADEC and Thrust Levers
24
e-books by eatpl.in · © 2026 · Do not copy or distribute
The LEAP does the same job with different boxes. The main fuel pump, driven by the gearbox, has a low pressure stage and a high pressure gear stage. Between them the fuel passes through the IDG oil cooling, and the LP stage also feeds the fuel return valve. A bypass valve on the pump protects the system against overpressure. Then come the main fuel filter, the fuel metering unit and the nozzles. The F M U contains the fuel metering valve, a high pressure shut-off valve that can close to stop an N2 overspeed, and a subsystem that trims the metered flow for thrust control malfunction accommodation. The engine actuators are powered by a separate split control unit and servo valve assembly, the S C U S V A. Both units convert FADEC electrical signals into hydraulic flow.
Engine oil system
Oil: lubricate and cool Lubricates the engine bearings and gearboxes Oil tank , lube and scavenge pump modulesFuel/oil heat exchanger : cold fuel cools the oilFilters, chip detectors , pressure relief and bypass valvesLEAP-1A adds a servo fuel heater and an air cooled oil cooler ; the FADEC controls fuel and oil temperature OIL TANK LUBE PUMP FILTER BEARINGS SCAVENGE FUEL/OIL HX and gearboxes relief / bypass valves chip detectors fuel cools the oil LEAP-1A adds servo fuel heater (SFH) air cooled oil cooler (ACOC) FADEC controls fuel and oil temperatures
Chapter 32 · Power Plant: Engine, FADEC and Thrust Levers
25
e-books by eatpl.in · © 2026 · Do not copy or distribute
The oil system lubricates the engine. Oil leaves the tank, the lube pump sends it through filters, with relief and bypass valves for protection, to the bearings and gearboxes. The scavenge pumps collect it again, past the chip detectors which catch metal particles from wear, and return it to the tank. On the way it passes the fuel oil heat exchanger, where cold fuel takes heat out of the oil, The LEAP adds a servo fuel heater and an air cooled oil cooler, and has a recirculation system for cooling and distribution. On the LEAP, oil passes through the servo fuel heater and the air cooled oil cooler before the main exchanger, and the FADEC controls the fuel and oil temperatures.
Engine air systems
Bleed air, clearances and stability Engine bleed supplies the pneumatic system and cools the engine compartment and turbines CFM56 (via the HMU): RACC on 5th stage air, HPTCC , LPTCC ; RACC valve closed = maximum clearance Cooling the turbine cases tightens clearances : better efficiency, lower EGT LEAP-1A (via the SCU/SVA): HPTACC, LPTACC, MTC , TBV for stall margin in transients LEAP: CORE ICE PROT (VBVs fully open) and BOOST ICE PROT (SB/BAI, 7th stage air) on the ENGINE page CFM56-5B FADEC → HMU RACC HP compressor rotor clearance; 5th stage air to the No. 3 bearing area valve closed = max clearance HPTCC HP compressor air cools the HP turbine case: better efficiency, lower EGT LPTCC fan air cools the LP turbine case LEAP-1A FADEC → SCU / SVA HPTACC / LPTACC fan air cools the turbine cases: smaller clearance MTC HP compressor air cools the HP turbine blades TBV HPC air dumped behind the LP turbine in transients VSV + VBV, core ice prot. SB / BAI valve 7th stage air: starting, booster ice protection
Chapter 32 · Power Plant: Engine, FADEC and Thrust Levers
26
e-books by eatpl.in · © 2026 · Do not copy or distribute
The engine air bleed system supplies the aircraft pneumatic system and also uses air for the engine itself. On the CFM, the FADEC uses the HMU to run three clearance control systems. Rotor active clearance control uses fifth stage air to set the gap between the HP compressor blades and their case; with its valve closed the clearance is at its maximum. HP and LP turbine clearance control blow cooling air onto the turbine cases, so they shrink, the gaps get smaller, efficiency improves and the E G T goes down. The LEAP does the same through the S C U S V A, adds modulated cooling of the HP turbine blades, and a transient bleed valve that improves stall margin during accelerations. Its core ice protection opens the bleed valves fully, and the booster anti-ice valve feeds seventh stage air to the booster.
Summary
Power plant in one page Engine Two-spool high bypass. N1 = fan, N2 = HP rotor. Gearbox on the HP shaft: oil, fuel, hydraulic pumps, IDG, FADEC alternator, starter.
FADEC One per engine, two channels (active/standby), own alternator, data via the EIU. ENG FADEC GND PWR on the maintenance panel.
Idle Modulated/minimum; approach (CFM: flaps not 0; LEAP: CONF 3/FULL or gear down); reverse idle slightly above forward.
Levers Stops TO/GA, IDLE, MAX REV; detents FLX/MCT, CL, REV IDLE. Between detents the higher rating counts.
FLX/MCT FLX if flex temperature > TAT. After take-off: TOGA or CL and back for MCT; FLX then lost.
Fuel LP pump, FOHE, HP pump, HMU/FMU, HP SOV, nozzles. ENG MASTER OFF closes LP and HP SOVs. FRV returns fuel to the tank.
Chapter 32 · Power Plant: Engine, FADEC and Thrust Levers
27
e-books by eatpl.in · © 2026 · Do not copy or distribute
Let us pull it together. The engine is a two-spool high bypass turbofan: N1 is the fan, N2 the high pressure rotor, and the gearbox on the HP shaft carries the oil, fuel and hydraulic pumps, the IDG, the FADEC alternator and the starter. Each engine has a two-channel FADEC with its own alternator, talking to the aircraft through the E I U. Idle comes in three flavours, and remember the different approach idle conditions for the CFM and the LEAP. The levers have three stops and three detents, and between detents the higher rating counts. FLX needs a flex temperature above TAT, and once you have gone to MCT after take-off, flex is gone. And the fuel runs from the LP pump through the heat exchanger, the HP pump and the metering unit to the nozzles, with ENG MASTER OFF closing both shut-off valves.