Welcome to the pressurization lesson. Up at flight level three nine zero the air outside is so thin that nobody could stay conscious for long, yet in the cabin people sleep, eat and read as if they were at a hill station. That comfort is the work of a small, clever system: two cabin pressure controllers, one outflow valve with three motors, two safety valves and a little unit that makes sure the doors never open against pressure. In this lesson we follow the system through a whole flight, learn the numbers examiners love, and then take over by hand when both automatic systems fail.
Lesson roadmap
Pressurization in four parts ATA chapter 21-20 . In normal operation the system is fully automatic : your job is to understand it, monitor it and take over when it fails.
1 · Why and what Cabin altitude, ΔP, the four functions, and the parts: 2 CPCs , outflow valve , 2 safety valves , RPCU .
2 · Automatic control Data sources, limits and the modes GN, TO, CL, CR, DE, AB with worked examples.
3 · Crew control The CABIN PRESS panel, MAN mode, DITCHING and the link with RAM AIR .
4 · ECAM and failures CAB PRESS page colours, the CRUISE page, the memo, and what happens when things fail.
Chapter 2 · Pressurization
2
e-books by eatpl.in · © 2026 · Do not copy or distribute
Here is our route through pressurization, chapter twenty-one twenty. First, why we pressurize at all, what cabin altitude and differential pressure mean, and the handful of parts that do the job: two cabin pressure controllers, one outflow valve, two safety valves and a residual pressure control unit. Second, the automatic control: where the controller gets its data, the limits it respects, and the six modes from ground to ground, with real numbers. Third, what the crew can do from the CABIN PRESS panel, including flying the cabin by hand, preparing for a ditching, and how the RAM AIR pushbutton works with the outflow valve. Finally, the ECAM pages, the colours that tell you something is wrong, and a set of what-happens-if cases that examiners love to ask.
Part 1 · Why pressurize
Cabin altitude and differential pressure 0 3 6 9 12 15 0 6 12 18 24 30 36 42 pressure altitude (thousands of feet) pressure (psi) outside air pressure cabin held at 8 000 ft ≈ 10.9 psi ΔP ≈ 8.06 psi the hull carries this load FL390 ≈ 2.9 psi sea level 14.7 psi Cabin altitude = the altitude whose pressure matches the cabin. ΔP = cabin pressure − outside pressure. In cruise the A320 keeps the cabin at about 8 000 ft or lower.
Chapter 2 · Pressurization
3
e-books by eatpl.in · © 2026 · Do not copy or distribute
Outside air pressure falls quickly with height. At sea level it is about fourteen point seven psi; at flight level three nine zero it is under three. We cannot keep the cabin at sea-level pressure up there, because the fuselage would have to carry a huge load. So we compromise. We pump air in with the packs and let it out more slowly through the outflow valve, keeping the cabin at the pressure of a moderate altitude, which we call the cabin altitude. The difference between cabin pressure and outside pressure is the differential pressure, written delta P. Look at the graph. With the cabin at eight thousand feet, about ten point nine psi, and the aircraft at flight level three nine zero, delta P is about eight point zero six psi. That is the highest delta P the A320 pressurization schedule normally uses.
Part 1 · What the system does
Four functions from gate to gate Pressurization is not just “in flight”. The controller has a job in every phase:
Ground Outflow valve fully open on the ground, so there is no pressure in the cabin.
Pre-pressurization During take-off, the cabin is pressurized slightly to avoid a pressure surge at rotation .
Pressurization in flight Adjusts cabin altitude and its rate of change for passenger comfort.
Depressurization After touchdown, releases the residual overpressure gradually before the valve opens fully.
Chapter 2 · Pressurization
4
e-books by eatpl.in · © 2026 · Do not copy or distribute
Think of the system as having four jobs, one for each part of the trip. On the ground the outflow valve is fully open, so there is no pressure difference across the doors. During take-off the controller pre-pressurizes the cabin a little. Why? At rotation the airflow round the fuselage changes suddenly, and without a small positive pressure the passengers would feel a pressure bump in their ears. In flight it adjusts the cabin altitude and, just as important, how fast it changes, because ears care more about rate than about altitude. After touchdown there is still a little overpressure in the cabin, so the controller releases it gently before the ground function opens the valve fully. We will meet each of these again as the named modes: ground, take-off, climb, cruise, descent and abort.
Part 1 · The parts and where they are
Where the pressurization parts sit on the A320 pressure hull (cockpit, cabin, holds) packs outflow valve right side, below flotation line 2 safety valves rear bulkhead, above the flotation line flotation line 2 cabin pressure controllers + residual pressure control unit · CABIN PRESS panel on the overhead Packs bring air in; one outflow valve meters it out; two safety valves protect the structure. Two controllers decide where the valve should be.
Chapter 2 · Pressurization
5
e-books by eatpl.in · © 2026 · Do not copy or distribute
Let us find the parts on the aircraft. The pressure hull is everything between the forward and rear pressure bulkheads: cockpit, cabin and the cargo holds. Air comes in from the packs under the centre fuselage and is spread through the cabin. It leaves through a single outflow valve, low on the right-hand side of the fuselage, just behind the aft cargo compartment, and below the flotation line, which matters for ditching. The two safety valves are on the rear pressure bulkhead, above the flotation line. The brains of the system, two cabin pressure controllers and a residual pressure control unit, sit with the other avionics, and the crew controls are on the CABIN PRESS panel on the overhead. Remember the simple picture: the packs fill, the outflow valve decides how fast air escapes, and that balance sets the cabin altitude.
Part 1 · Control architecture
Two controllers, three motors, one valve ADIRS 1+2+3 static pressure, baro ref FMGC landing elevation, dest QNH LGCIU 1+2 flight / ground EIU 1+2 thrust lever angle RAM AIR pb emergency ram air the same inputs go to CPC 2 CPC 1 active (this flight) manual backup own supply + sensor CPC 2 standby (this flight) manual backup not connected cross- channel MOT 1 MOT 2 MAN MOT CABIN PRESS panel MODE SEL · LDG ELEV · MAN V/S CTL · DITCHING direct, in MAN OUTFLOW VALVE one actuator, three motors Each automatic system = one CPC + its own AUTO motor . The MAN motor is driven from the panel. Any one of the three motors can move the valve.
Chapter 2 · Pressurization
6
e-books by eatpl.in · © 2026 · Do not copy or distribute
Here is how the decisions reach the valve. Both cabin pressure controllers, the C P Cs, receive the same inputs. The air data and inertial reference system gives static pressure and the baro correction. The flight management and guidance computer gives the landing field elevation and destination QNH. The landing gear control interface unit says flight or ground, the engine interface unit gives thrust lever position, and the RAM AIR pushbutton is an input too. The two controllers talk to each other over a cross-channel link. Each automatic system is a controller plus its own motor on the outflow valve actuator: motor one for system one, motor two for system two. The third motor is the manual motor, which the crew drives from the CABIN PRESS panel. Any one of the three independent motors can move the valve on its own.
Part 1 · Cabin pressure controllers
CPC 1 and CPC 2: active and standby Two identical, independent, digital controllers; one active , the other on standby Automatic transfer 70 s after each landing , or at once if the active system fails They send cabin data and warnings to ECAM For MAN mode: a backup section ; the one in the CPC 1 position has its own power supply and pressure sensor and feeds ECAM MODE SEL at MAN for at least 10 s , then back to AUTO, selects the other system One active, one on standby Flight 1 SYS 1 active SYS 2 standby 70 s after landing Flight 2 SYS 2 active SYS 1 standby 70 s after landing Flight 3 SYS 1 active SYS 2 standby Active system fails → automatic transfer to the other
Chapter 2 · Pressurization
7
e-books by eatpl.in · © 2026 · Do not copy or distribute
The two cabin pressure controllers are identical and independent, and only one works at a time. The other sits on standby, watching. Seventy seconds after every landing they swap, so each system flies alternate sectors and a hidden fault in the standby one cannot lie dormant for long. If the active system fails in flight, the transfer happens immediately and automatically; you will see the failed system in amber on the ECAM. Each controller also has a manual backup section for MAN mode. Only the one in the controller number one position is connected, with its own independent power supply and its own pressure sensor, and in MAN mode it gives the ECAM the cabin altitude, delta P and valve position. One more trick to remember: holding MODE SEL in MAN for at least ten seconds and then returning to AUTO selects the other system.
Part 1 · Outflow valve
The outflow valve: two flaps and three motors On the right side of the fuselage, behind the aft cargo compartment , below the flotation line A flush, skin-mounted rectangular frame carrying an inward - and an outward-opening flap One actuator: 2 AUTO motors + 1 MAN motor ; any one can drive the valve Opens → more air out → cabin altitude climbs ; closes → cabin descends Position to ECAM: from the operating controller (AUTO) or the CPC 1 backup section (MAN) cabin (inside) outside inward flap outward flap actuator MOT 1 MAN MOT 2 opens → more air out → cabin altitude climbs
Chapter 2 · Pressurization
8
e-books by eatpl.in · © 2026 · Do not copy or distribute
The outflow valve is the only door through which the controller lets air out, so it sets the cabin altitude. It sits in the belly skin on the right side, behind the aft hold, below the flotation line. It is not a round butterfly: it is a flush, rectangular frame in the skin carrying two flaps linked to one actuator. One flap opens inward and the other opens outward. Look at the actuator. It holds three electric motors: two automatic ones, one for each system, and one manual motor. Now watch the cabin altitude gauge. When the valve opens, more air escapes than the packs supply, so cabin pressure falls and the cabin altitude climbs. When it closes, the cabin altitude comes down again. In automatic mode the operating controller reports the valve position to the ECAM; in manual mode the backup section in the CPC one position does it.
Part 1 · Safety valves
Two safety valves protect the structure Two independent, pneumatic valves: no controller neededOpen if cabin pressure is 8.6 psi above outside, or 1 psi below it (negative relief) On the rear pressure bulkhead , above the flotation line ECAM: SAFETY and the valve symbol turn amber when either valve is open ECAM sees them open at an indicated ΔP of 8.9–9.7 psi (sensor accuracy in MAN, and ΔP drops as they open) rear pressure bulkhead cabin side tail cone side spring poppet lifts at ΔP 8.6 psi +8.6 psi cabin above outside: overpressure relief −1 psi outside above cabin: negative relief
Chapter 2 · Pressurization
9
e-books by eatpl.in · © 2026 · Do not copy or distribute
The safety valves are the last line of defence for the structure, and they need no electrics or controller at all. There are two of them, independent and pneumatic, mounted on the rear pressure bulkhead above the flotation line. Each works like a spring-loaded poppet. Watch the differential pressure gauge. Normally the poppet stays seated. If cabin pressure ever reaches eight point six psi above outside pressure, for example because the outflow valve has jammed shut, the poppet lifts and cabin air is vented aft and overboard. When delta P falls back, the poppet reseats. They also protect the other way: if outside pressure gets more than one psi above cabin pressure, they open to let air in. On the ECAM, SAFETY turns amber when either valve is open; because of sensor accuracy, the indicated delta P at that moment can be anywhere from eight point nine to nine point seven.
Part 1 · Residual pressure control unit
The RPCU: no pressure left on the ground Automatically depressurizes the aircraft if residual pressure remains on the ground Opens the outflow valve when all of these are true: • valve not fully open · • both CPCs failed or MAN selected • aircraft on ground · • all engines shut down or all ADIRS < 100 kt Why: in MAN the valve does not open automatically at touchdown, and doors must never open against pressure Outflow valve not fully open Both CPCs failed MODE SEL at MAN Aircraft on ground All engines shut down All ADIRS < 100 kt OR OR AND RPCU opens outflow valve
Chapter 2 · Pressurization
10
e-books by eatpl.in · © 2026 · Do not copy or distribute
The residual pressure control unit, or R P C U, is a small safety net for the ground. Normally the active controller opens the outflow valve after landing. But in manual mode, or with both controllers failed, nothing does that automatically, and a cabin with even a little pressure left in it is dangerous: a door opened against pressure can be blown open. So the R P C U opens the outflow valve by itself when four conditions are met together. The valve is not fully open. Both controllers have failed, or MAN is selected. The aircraft is on the ground. And either all engines are shut down, or all the air data references show less than one hundred knots. Read the logic diagram from left to right: two OR gates feed one AND gate, and only when everything is true does the valve open.
Part 2 · Automatic control
Where the controller gets its targets Normally uses landing elevation and QNH from the FMGC and pressure altitude from ADIRS Crew only monitors : cabin pressure follows schedules built from FMGS data No FMGC data: uses the captain BARO reference (ADIRS) and the LDG ELEV knob setting Cabin limited to ≈ 8 000 ft in CRUISE Up to 14 100 ft allowed in ground, climb and descent for high airfields Normal (LDG ELEV at AUTO) • FMGC : landing elevation + QNH • ADIRS : aircraft pressure altitude • optimised schedule; crew only monitors ECAM: LDG ELEV AUTO + value, in green FMGC data not available • crew pulls and turns LDG ELEV to the field • controller uses captain BARO ref (ADIRS) • still automatic (“semi-automatic”) set it from the ECAM value, not the knob scale ≈ 8 000 ft max cabin in cruise 14 100 ft GN, CL, DE: high airfields
Chapter 2 · Pressurization
11
e-books by eatpl.in · © 2026 · Do not copy or distribute
In automatic mode the controller needs two things: where the aircraft is now, and where it will land. Normally it takes the landing field elevation and the destination QNH from the flight management computer, and the aircraft pressure altitude from the air data references, and builds an optimised schedule. The crew does nothing except monitor. If the flight management data are not available, the crew only has to pull and turn the LDG ELEV knob to the destination elevation. The controller then uses that value, together with the captain baro reference from the air data system, and still runs everything automatically; some people call this semi-automatic. Two limits sit on top of every schedule. In cruise the cabin is limited to about eight thousand feet. In the ground, climb and descent phases the system can go up to fourteen thousand one hundred feet, so it can serve very high airfields.
Part 2 · The automatic modes
The pressurization profile, mode by mode airfield elevation aircraft cabin GN · ground TO CL · climb CR · cruise DE · descent GN · ground valve fully open −400 ft/min fixed law level-off value, max ≈ 8 000 ft max 750 ft/min +500 ft/min to ΔP 0.1 psi uses aircraft V/S ΔP up to 8.06 psi to field + 0.1 psi open 55 s after lift-off touchdown schematic, not to scale: the small dips at take-off and landing are exaggerated Abort (AB) is the sixth mode: if the aircraft does not climb after take-off, the cabin returns to take-off altitude + 0.1 psi.
Chapter 2 · Pressurization
12
e-books by eatpl.in · © 2026 · Do not copy or distribute
This graph follows a whole flight. The dark line is the aircraft; the orange line is the cabin. On the ground, mode G N, the outflow valve is fully open. As take-off starts, mode T O pre-pressurizes the cabin: it descends at four hundred feet per minute until delta P reaches zero point one psi, which is why the orange line dips slightly below the field. At lift-off the climb mode starts, and the cabin climbs on a fixed law that takes into account the aircraft rate of climb. In cruise the controller holds the level-off value, never above about eight thousand feet. In descent it brings the cabin down, at no more than seven hundred and fifty feet per minute, so that just before landing cabin pressure is field pressure plus zero point one psi. After touchdown the remaining pressure is released at five hundred feet per minute and the valve is fully open fifty-five seconds after landing.
Part 2 · GN and TO in detail
Ground, take-off and touchdown numbers GN : before take-off the valve is fully open , so no residual pressureTO : pre-pressurizes at 400 ft/min until ΔP = 0.1 psi ; at lift-off the climb phase beginsWorked example: 0.1 psi ≈ 190 ft at sea level → about 28 s at 400 ft/min At touchdown , remaining pressure is released at 500 ft/min Valve fully open 55 s after landing; CPCs swap 70 s after landing Take-off (TO) field elevation lift-off → CL −400 ft/min ΔP 0.1 psi valve fully open Sea level: 0.1 psi ≈ 190 ft of cabin → ≈ 28 s at 400 ft/min Landing (DE → GN) touchdown field + 0.1 psi +500 ft/min 55 s: fully open 70 s: CPCs swap Both times are counted from landing
Chapter 2 · Pressurization
13
e-books by eatpl.in · © 2026 · Do not copy or distribute
Let us zoom in on both ends of the flight. On the ground the controller keeps the outflow valve fully open, so there can be no residual pressure. When take-off begins, the controller starts pre-pressurizing at four hundred feet per minute, cabin going down, until delta P reaches zero point one psi. Work it out: at sea level zero point one psi is roughly one hundred and ninety feet of cabin altitude, so at four hundred feet per minute it takes about twenty-eight seconds. At lift-off the climb phase starts. Now the landing. The descent schedule has brought the cabin to about zero point one psi above field pressure. At touchdown that small overpressure is released at five hundred feet per minute, and fifty-five seconds after landing the outflow valve is driven fully open. Seventy seconds after landing the two systems swap, ready for the next sector.
Part 2 · CL and CR in detail
Climb and cruise: a worked example to Leh CL : cabin altitude follows a fixed, pre-programmed law that uses the actual rate of climb CR : holds the level-off value or the landing field elevation , whichever is higher …but the cruise target is limited to ≈ 8 000 ft Delhi → Leh (10 682 ft): cruise cabin stays at ≈ 8 000 ft; the descent takes it up towards Leh Delhi → Mumbai: the level-off value is higher than the field, so that is held Delhi (777 ft) → Leh (10 682 ft) 0 4,000 8,000 12,000 14,100 CR: capped ≈ 8 000 ft DE: up to Leh 14 100 ft limit (GN, CL, DE) cabin altitude (ft) through the flight → Cruise target = level-off value or landing field elevation, whichever is higher , but never above ≈ 8 000 ft.
Chapter 2 · Pressurization
14
e-books by eatpl.in · © 2026 · Do not copy or distribute
In the climb the cabin follows a fixed, pre-programmed law, and because that law takes into account the aircraft actual rate of climb, a slow climb gives a gentle cabin climb. In cruise the rule is: hold the cabin at the level-off value or at the landing field elevation, whichever is higher, but never above about eight thousand feet. Try it on a flight from Delhi to Leh, where the field is at about ten thousand seven hundred feet. The landing elevation is higher than the level-off value, but the cruise target is capped at about eight thousand feet, so the cabin waits there. In the descent the cabin then climbs towards Leh field pressure, which is allowed because ground, climb and descent can go up to fourteen thousand one hundred feet. For Delhi to Mumbai, at sea level, the level-off value is the higher of the two, so the controller simply holds it.
Part 2 · DE and AB in detail
Descent and abort: worked numbers DE : cabin descends so that cabin pressure = landing field pressure + 0.1 psi shortly before landingMaximum cabin rate of descent: 750 ft/min Example: 8 000 ft → ≈ 2 800 ft for Bengaluru = 5 200 ft ÷ 750 ≈ 7 min minimum AB : if the aircraft does not climb after take-off, the cabin is not allowed to climb Abort sets the cabin back to take-off altitude + 0.1 psi , ready to land again Worked example: descent (DE) Cabin in cruise 8 000 ft Bengaluru field ≈ 3 000 ft Target: field + 0.1 psi ≈ 2 800 ft Cabin must descend ≈ 5 200 ft At max 750 ft/min ≥ ≈ 7 min Abort (AB) take-off field aircraft: no climb cabin TO alt + 0.1 psi
Chapter 2 · Pressurization
15
e-books by eatpl.in · © 2026 · Do not copy or distribute
In descent the controller works backwards from the landing. It chooses a cabin rate of descent so that, shortly before touchdown, cabin pressure equals landing field pressure plus zero point one psi, and it never exceeds seven hundred and fifty feet per minute. Here is a worked example. Cruising with the cabin at eight thousand feet, you descend into Bengaluru, about three thousand feet. Field pressure plus zero point one psi is a cabin of about two thousand eight hundred feet, so the cabin must come down about five thousand two hundred feet. At the maximum rate that takes at least seven minutes, which is why a very short, steep descent can leave the cabin behind. The abort mode covers a take-off after which the aircraft does not climb, for example an immediate return. The controller stops the cabin climbing and sets it back to take-off altitude plus zero point one psi.
Part 3 · Crew controls
The CABIN PRESS panel CABIN PRESS MAN V/S CTL UP DN MODE SEL FAULT MAN A U T O LDG ELEV AUTO −2 0 2 4 6 8 10 12 14 DITCHING ON 1 MAN V/S CTL spring-loaded toggle; works only in MAN UP opens the valve · DN closes it 2 MODE SEL pb AUTO (dark) / MAN (white) FAULT amber: both auto systems failed 3 LDG ELEV knob AUTO: elevation from the FMGS pull + turn: −2 000 … +14 000 ft 4 DITCHING pb guarded; ON in white closes valves that could let water in 1 2 3 4 Normal flight: all legends dark, LDG ELEV at AUTO. Memo MAN LDG ELEV (green) when the knob is out of AUTO.
Chapter 2 · Pressurization
16
e-books by eatpl.in · © 2026 · Do not copy or distribute
This is the CABIN PRESS panel on the overhead, drawn as you will see it in normal flight: everything dark and the landing elevation knob at AUTO. Number one is MAN V S C T L, a spring-loaded toggle switch with UP and DN positions; it only does anything when MAN is selected. Number two is the MODE SEL pushbutton. Its lower legend shows MAN in white when you select manual mode, and its upper FAULT light comes on amber, together with the ECAM caution, only when both automatic systems have failed. Number three is the LDG ELEV knob. At AUTO the system uses the elevation from the flight management system; to leave AUTO you pull it out and turn it, from minus two thousand to plus fourteen thousand feet. Number four is the guarded DITCHING pushbutton, whose ON legend is white. Notice how the dark-cockpit idea works here: no lights means normal.
Part 3 · Crew controls
Every switch position and what it does Control Position Effect LDG ELEV AUTO Schedule built from FMGS data LDG ELEV Pulled and turned Uses the selected elevation (−2 000 to +14 000 ft); set it from the ECAM value. Memo MAN LDG ELEV (green) MODE SEL AUTO One automatic system drives the outflow valve MODE SEL MAN (white) Power cut to the AUTO motors; MAN V/S CTL drives the MAN motor. FAULT does not come on MODE SEL FAULT (amber) Both automatic systems faulty, with an ECAM cautionMAN V/S CTL UP / DN Only in MAN. UP opens the valve (cabin climbs), DN closes it. Use short inputs DITCHING ON (white) Close signal to outflow valve, emergency ram air inlet, avionics inlet and extract valves, pack flow control valves
MAN selected for at least 10 s and then AUTO again selects the other system.
Chapter 2 · Pressurization
17
e-books by eatpl.in · © 2026 · Do not copy or distribute
This table is worth learning line by line, because type-rating questions come straight from it. LDG ELEV at AUTO uses flight management data. Pulled and turned, it uses the selected elevation, anywhere from minus two thousand to plus fourteen thousand feet. Always set it from the value shown on the ECAM, because the knob scale is only an indication, and expect the green memo MAN LDG ELEV. MODE SEL at AUTO lets one automatic system run the valve. Pressed to MAN, the white legend appears, power to the automatic motors is cut, and the toggle switch drives the manual motor; note that FAULT does not come on just because you chose MAN. The amber FAULT light means both automatic systems are faulty. On the toggle, UP opens the valve and the cabin climbs; DN closes it and the cabin descends. DITCHING sends close signals to the valves that could let water in.
Part 3 · Manual mode
Flying the cabin by hand Used when both automatic systems fail (MODE SEL FAULT) 1. MODE SEL → MAN : AUTO motors lose power, the MAN motor takes over2. MAN V/S CTL UP (valve opens, cabin climbs) or DN (valve closes, cabin descends)Valve moves slowly ; ECAM can take up to 5 s to show a change: use short inputs In MAN the valve does not open automatically at touchdown : the RPCU covers the ground cabin (inside) outside inward flap outward flap actuator MOT 1 MAN MOT 2 opens → more air out → cabin altitude climbs
Chapter 2 · Pressurization
18
e-books by eatpl.in · © 2026 · Do not copy or distribute
If both automatic systems fail, the MODE SEL FAULT light comes on and you take over. First, press MODE SEL so that MAN appears. That cuts power to the two automatic motors and hands the outflow valve to the manual motor. Second, use the MAN V S C T L toggle. Push it up and the valve opens, more air escapes, and the cabin vertical speed goes positive: the cabin climbs. Push it down and the valve closes, and the cabin descends. Watch the vertical speed on the ECAM, not the valve. The manual motor is slow, and because of the limited resolution of the position display, the ECAM can take up to five seconds to show that the valve has moved. So use short, patient inputs and let the rate settle. Finally, remember that in manual mode the valve does not open by itself at touchdown; that is exactly the job of the R P C U.
Part 3 · Ditching
DITCHING: close everything below the water line water / flotation line avionics vent inlet + extract emergency ram air inlet pack flow control valves FWD cargo outlet isol valve* outflow valve DITCHING pb → ON “close” signal from the operating system Safety valves: above the water line (rear bulkhead), not commanded. * where forward cargo ventilation is fitted. Under manual control the outflow valve is NOT closed automatically. Caution: DITCHING ON on the ground with the low-pressure ground cart connected and all doors closed builds up a differential pressure .
Chapter 2 · Pressurization
19
e-books by eatpl.in · © 2026 · Do not copy or distribute
Before a ditching the crew presses the guarded DITCHING pushbutton. The operating controller then sends a close signal to everything that could let sea water flood the fuselage: the outflow valve, which we know is below the flotation line; the emergency ram air inlet; the avionics ventilation inlet and extract valves; the pack flow control valves; and, on aircraft with forward cargo ventilation, the forward cargo outlet isolation valve. Two details catch people out. First, the outflow valve is not closed automatically if the system is in manual mode, so in MAN you must close it yourself with the toggle. Second, a ground caution: if DITCHING is selected with the low-pressure ground air cart connected and all doors closed, air keeps coming in and cannot get out, so a differential pressure builds up in the cabin on the ground.
Part 3 · RAM AIR and the outflow valve
RAM AIR: when does air really come in? RAM AIR pb opens the emergency ram air inlet , provided DITCHING is not selected If ΔP ≥ 1 psi : a check valve downstream stays shut, no ram air flows ; outflow valve control normal If ΔP < 1 psi : ram air goes to the mixer unit …and the outflow valve opens about 50 % if under automatic control Under manual control the valve does not open automatically RAM AIR pb → ON DITCHING selected? yes Ram air inlet stays closed no Ram air inlet opens ΔP ≥ 1 psi check valve stays shut: no ram air; OFV control normal ΔP < 1 psi ram air → mixer unit; outflow valve opens about 50 %… if AUTO ≈ 50 % open if MAN no auto opening
Chapter 2 · Pressurization
20
e-books by eatpl.in · © 2026 · Do not copy or distribute
The RAM AIR pushbutton belongs to air conditioning, but it talks directly to pressurization, so let us link them. Pressing it opens the emergency ram air inlet, as long as DITCHING is not selected. Whether any air actually flows depends on delta P. If the cabin is still pressurized by one psi or more, a check valve downstream of the ram air door stays shut, so nothing comes in, and the outflow valve is controlled normally. Once delta P is below one psi, typically after descending to a safe altitude, ram air flows to the mixer unit, and the outflow valve is driven about fifty per cent open to let that air through the cabin and out. That automatic opening only happens if the valve is under automatic control. In manual mode the valve stays where you put it, so you must open it yourself.
Part 4 · ECAM
The ECAM CAB PRESS page CAB PRESS LDG ELEV AUTO 500 FT ΔP PSI V/S FT/MN CAB ALT FT 0 8 4.1 2 0 2 250 0 10 4150 SYS 1 SAFETY VENT INLET OUTLET PACK 1 PACK 2 TAT +19 °C GW 60300 KG 1 2 3 4 5 6 7 8 1 LDG ELEV knob AUTO or MAN + the value in use 2 ΔP green; amber ≤ −0.4 or ≥ 8.5 psi 3 Cabin V/S pulses green ≥ 1 750 ft/min 8 VENT INLET / OUTLET avionics skin valves: next lesson 4 CAB ALT pulses ≥ 8 800 ft · red ≥ 9 550 ft 5 SYS 1 / SYS 2 active green · faulty amber · MAN 6 SAFETY amber when a safety valve opens 7 Outflow valve amber if > 95 % open in flight (AUTO)
Chapter 2 · Pressurization
21
e-books by eatpl.in · © 2026 · Do not copy or distribute
This is the CAB PRESS system page. Across the top, number one: LDG ELEV with AUTO or MAN and the elevation in use, in green with cyan units. Then three gauges. Delta P is green normally and goes amber below minus zero point four or above eight point five psi. Cabin vertical speed pulses green above one thousand seven hundred and fifty feet per minute. Cabin altitude pulses green from eight thousand eight hundred feet and turns red at nine thousand five hundred and fifty. Underneath is the fuselage outline. The active system, SYS one or SYS two, is shown in green; a faulty one is amber, and an inactive one is not shown at all. MAN appears when MODE SEL is in manual. On the right, SAFETY and the safety valve symbol go amber if either valve opens. The outflow valve needle goes amber if, in automatic mode, the valve opens more than ninety-five per cent in flight.
Part 4 · ECAM: normal and failed
Spot the difference: normal and failed pages Normal cruise Both systems failed, crew in MAN CAB PRESS LDG ELEV AUTO 500 FT ΔP PSI V/S FT/MN CAB ALT FT 0 8 7.9 2 0 2 0 0 10 7600 SYS 1 SAFETY VENT INLET OUTLET PACK 1 PACK 2 TAT +19 °C GW 60300 KG CAB PRESS LDG ELEV AUTO ΔP PSI V/S FT/MN CAB ALT FT 0 8 8.7 2 0 2 600 0 10 9600 SYS 1 SYS 2 MAN SAFETY VENT INLET OUTLET PACK 1 PACK 2 TAT +19 °C GW 60300 KG Right: both systems amber , MAN shown, ΔP amber , cabin altitude red , SAFETY amber with the valve open.
Chapter 2 · Pressurization
22
e-books by eatpl.in · © 2026 · Do not copy or distribute
Compare the two pages. On the left is a normal cruise: SYS one in green, delta P seven point nine, cabin altitude seven thousand six hundred, everything green, safety valve closed. On the right both automatic systems have failed. Both SYS titles are amber, and MAN appears in green because the crew has selected manual mode. No landing elevation value is shown, because the system does not use one in manual mode. The crew has let the outflow valve close too far. Delta P has risen to eight point seven, amber because it is above eight point five. A safety valve has opened, so SAFETY and its valve symbol are amber. And the cabin altitude, nine thousand six hundred feet, is red because it is above nine thousand five hundred and fifty. The cure here: short UP inputs on the toggle to reopen the outflow valve, while watching the vertical speed.
Part 4 · ECAM thresholds
Numbers that change colour on the ECAM Indication Advisory (pulses green) Abnormal colour Cabin V/S ≥ 1 750 ft/min , stops below 1 650 — ΔP > 1.5 psi in flight phase 7, stops at 1 psi Amber at ≤ −0.4 or ≥ 8.5 psiCabin altitude ≥ 8 800 ft , stops below 8 600 Red at ≥ 9 550 ft SYS 1 / SYS 2 Active system in green Amber when faulty; MAN shown in MANSafety valves Closed: green symbol Amber when either is openOutflow valve Normal: green Amber if > 95 % open in flight (AUTO)DOOR/OXY V/S Pulses if |V/S| > 1 800 ft/min for 5.5 s Shown in phases 5, 6 and 7
Each pulse threshold has a lower reset value, so the display does not flicker on and off.
Chapter 2 · Pressurization
23
e-books by eatpl.in · © 2026 · Do not copy or distribute
Here are the numbers that make the page change colour, in one place. Pulsing green is an advisory: it draws your eye before anything is wrong. The cabin vertical speed pulses at one thousand seven hundred and fifty feet per minute and stops below one thousand six hundred and fifty. Delta P pulses if it is still above one and a half psi during flight phase seven, the approach, and stops at one psi, because you want the cabin almost depressurized by touchdown. It turns amber below minus zero point four or above eight point five psi. Cabin altitude pulses from eight thousand eight hundred feet, stops below eight thousand six hundred, and turns red at nine thousand five hundred and fifty. Faulty systems, an open safety valve, or an outflow valve more than ninety-five per cent open in flight in automatic mode, are all amber. Notice the pattern: each pulse threshold has a lower reset value.
Part 4 · Other ECAM displays
CRUISE page, DOOR/OXY page and the memo CRUISE page: LDG ELEV, ΔP , CAB V/S and CAB ALT , with the same colour rulesIn MAN the CRUISE page shows cabin V/S on a small gauge DOOR/OXY page shows cabin V/S in flight phases 5, 6 and 7 It pulses green if |V/S| > 1 800 ft/min for more than 5.5 s ; stops below 1 600 Memo MAN LDG ELEV (green) whenever the knob is not at AUTO CRUISE page, air section AIR LDG ELEV AUTO 500 FT ΔP 6.4 PSI CAB V/S ↗ 250 FT/MN CAB ALT 4150 FT CKPT FWD AFT 20 22 23 (zone temperatures) DOOR/OXY page (phases 5, 6, 7) V/S ↘ 1650 FT/MN pulses if |V/S| > 1 800 Memo MAN LDG ELEV knob out of AUTO
Chapter 2 · Pressurization
24
e-books by eatpl.in · © 2026 · Do not copy or distribute
You will not always have the CAB PRESS page in front of you. In cruise the system display usually shows the CRUISE page, and its air section repeats the essentials: landing elevation, delta P, cabin vertical speed with a small arrow, and cabin altitude, with the same thresholds and colours as the main page. In manual mode the cabin vertical speed there is shown on a small gauge instead of just a number. The DOOR OXY page also shows cabin vertical speed during flight phases five, six and seven, that is, from lift-off to the approach. It pulses green when the rate is above one thousand eight hundred feet per minute for more than five and a half seconds, and stops below one thousand six hundred. Finally, the green memo MAN LDG ELEV reminds you whenever the landing elevation knob is out of AUTO.
Part 4 · What happens if…
Failure cases you must be able to explain Event What the system does What you see / do Active CPC fails Automatic transfer to the other system Failed SYS amber ; pressurization continues normally Both CPCs fail No automatic control MODE SEL FAULT + ECAM caution → MAN, fly with MAN V/S CTL FMGC data lost Uses captain BARO ref + LDG ELEV Pull and turn LDG ELEV to the field (check on ECAM) Outflow valve stuck closed Safety valves open at +8.6 psi SAFETY amber , ΔP high Landing in MAN Valve does not open at touchdown RPCU opens it on ground (engines off or all ADIRS < 100 kt) RAM AIR on, ΔP < 1 psi OFV ≈ 50 % open in AUTO only In MAN open the valve yourself Ditching Close signal to valves below the water In MAN close the outflow valve with DN
Chapter 2 · Pressurization
25
e-books by eatpl.in · © 2026 · Do not copy or distribute
Let us pull it together with failure cases. If the active controller fails, the other takes over automatically; the failed system shows amber and the flight goes on normally. If both fail, MODE SEL FAULT comes on with an ECAM caution, and you select MAN and fly the cabin with the toggle. If flight management data are lost, the controller uses the captain baro reference and whatever you set on the LDG ELEV knob, so set the field elevation and check it on the ECAM. If the outflow valve sticks closed, delta P climbs until the safety valves open at eight point six psi, and SAFETY turns amber. If you land in manual, the valve does not open at touchdown, but the residual pressure control unit opens it on the ground. With RAM AIR on below one psi, the automatic system opens the valve about half way, but in manual you must do it. And for a ditching in manual, close the valve yourself.
Exam traps
Classic pressurization traps Toggle direction MAN V/S CTL UP opens the valve and the cabin climbs . It is not “pressure up”.
FAULT vs MAN MODE SEL FAULT = both auto systems failed. Selecting MAN does not light FAULT.
8.06 vs 8.6 vs 8.5 Schedule max ΔP 8.06 ; safety valves 8.6 (indicated 8.9–9.7); ECAM amber at 8.5 .
Where the valves are Outflow valve below the flotation line (right side, aft). Safety valves above it (rear bulkhead).
Timing after landing Valve fully open 55 s after landing; CPCs swap 70 s after landing.
MAN mode surprises In MAN: no auto opening at touchdown, no 50 % opening with RAM AIR, no auto closing for DITCHING.
Chapter 2 · Pressurization
26
e-books by eatpl.in · © 2026 · Do not copy or distribute
Here are the traps that catch people in type-rating exams. The toggle switch: UP opens the outflow valve, so the cabin climbs; it is not a pressure-up switch. The FAULT light means both automatic systems have failed; selecting MAN on its own does not light it. Keep the pressure numbers apart: eight point zero six psi is the normal schedule maximum, eight point six psi is the safety valve setting, with the ECAM seeing them open at an indicated eight point nine to nine point seven, and the ECAM delta P turns amber at eight point five. The outflow valve is below the flotation line, the safety valves above it. The valve is fully open fifty-five seconds after landing, and the controllers swap after seventy. And manual mode switches off three automatic actions: opening at touchdown, opening fifty per cent with RAM AIR, and closing for ditching.
Summary
Pressurization on one page Parts 2 CPCs (one active), 1 outflow valve with 2 AUTO + 1 MAN motor, 2 pneumatic safety valves, RPCU, CABIN PRESS panel.
Limits Cabin ≈ 8 000 ft in cruise, 14 100 ft in GN/CL/DE; schedule ΔP ≤ 8.06 psi; safety valves +8.6 / −1 psi.
Modes GN open · TO −400 ft/min to 0.1 psi · CL law · CR level-off or field (higher) · DE ≤ 750 ft/min to field + 0.1 psi · AB.
Ground Touchdown +500 ft/min; fully open 55 s; CPCs swap 70 s; RPCU in MAN or double failure.
Panel LDG ELEV AUTO / −2 000…14 000 ft · MODE SEL MAN / FAULT · MAN V/S CTL UP = open · DITCHING.
ECAM ΔP amber ≥ 8.5; V/S pulse 1 750; CAB ALT pulse 8 800, red 9 550; SAFETY amber; OFV amber > 95 %.
RAM AIR Inlet opens unless DITCHING; flows only if ΔP < 1 psi; OFV ≈ 50 % in AUTO only.
Ditching Closes OFV, ram air inlet, avionics inlet/extract, pack valves, FWD cargo outlet. Not the OFV in MAN.
Chapter 2 · Pressurization
27
e-books by eatpl.in · © 2026 · Do not copy or distribute
Let us sum up. The system has two controllers, only one active, swapping seventy seconds after each landing; one outflow valve with two automatic motors and one manual motor; two pneumatic safety valves set at plus eight point six and minus one psi; and a residual pressure control unit for the ground. The cabin is held at about eight thousand feet or below in cruise, with up to fourteen thousand one hundred feet allowed in the ground, climb and descent phases, and a normal maximum delta P of eight point zero six psi. Remember the mode numbers: four hundred feet per minute and zero point one psi for take-off, seven hundred and fifty for descent, five hundred after touchdown, and fifty-five seconds to fully open. Know every position on the panel, the ECAM colour thresholds, how RAM AIR and DITCHING act on the outflow valve, and the three things manual mode will not do for you.