A320 Aircraft Systems · Chapter 3
Ventilation and Cargo How the A320 keeps its avionics cool, its batteries, lavatories and galleys vented, and its cargo holds fresh and warm, and what the crew sees and does when it goes wrong.
avionics FWD hold AFT hold Cool electronics, fresh holds AEVC · BLOWER · EXTRACT · HOT AIR © 2026 eatpl.in. For the personal study of eatpl.in students only. Do not copy or distribute.
e-books by eatpl.in · © 2026 · Do not copy or distribute
Welcome to ventilation and cargo. Behind every screen in the cockpit sits a rack of hot electronics, and below your feet are two cargo holds that may carry animals, flowers or medicines. This lesson is about the quiet systems that look after them: the avionics ventilation with its fans, skin valves and skin heat exchanger, the small venturis and fans that vent the batteries, lavatories and galleys, and the cargo ventilation and heating. As always, we will learn the logic, the panel and the ECAM, and what happens when there is smoke or a failure.
Lesson roadmap
Ventilation and cargo in four parts ATA 21-30 (ventilation) and 21-40 (cargo). Most of it is automatic: learn the logic, the panels and the ECAM.
1 · Avionics ventilation Fans, valves, skin heat exchanger and the AEVC ; open , closed and intermediate circuits.
2 · Abnormal and ECAM BLOWER and EXTRACT faults, OVRD , smoke , controller failure; ECAM symbols.
3 · Other ventilation Batteries (skin venturi), lavatories and galleys (extraction fan).
4 · Cargo FWD and AFT ventilation and heating , the CARGO HEAT panel, overheat reset, ECAM COND .
Chapter 3 · Ventilation and Cargo
2
e-books by eatpl.in · © 2026 · Do not copy or distribute
Here is the plan. Part one is the avionics ventilation: the two fans, the skin valves, the skin heat exchanger and the controller that runs them, and the three normal configurations, called open circuit, closed circuit and intermediate. Part two covers the abnormal cases, which are favourite interview topics: blower and extract faults, the override positions, the smoke configuration and a controller failure, plus how all this looks on the ECAM. Part three is short: how the batteries, lavatories and galleys are ventilated. Part four is the cargo holds: how cabin air is pulled through them, how the aft hold, and on some aircraft the forward hold, is heated with hot bleed air, the CARGO HEAT panel, the overheat logic and the ECAM COND page.
Overview
Where the ventilation systems are avionics avionics ventilation (AEVC) BAT batteries: skin venturi FWD hold AFT hold lavatory and galley extraction fan → near the outflow valve outflow valve Cargo holds: cabin air pulled through by extraction fans; hot bleed air added for heating (customer options) Avionics ventilation (AEVC) · battery ventilation · lavatory and galley extraction · cargo ventilation and heating
Chapter 3 · Ventilation and Cargo
3
e-books by eatpl.in · © 2026 · Do not copy or distribute
Let us place the systems on the aircraft. Under the flight deck is the avionics compartment, packed with computers. Its avionics ventilation is fully automatic, run by the avionics equipment ventilation controller, the A E V C, and it also cools the instrument and circuit-breaker panels on the flight deck. The batteries are ventilated by a simple venturi in the skin. The lavatories and galleys have an extraction fan that pulls cabin air through them and dumps it near the outflow valve at the back. Below the cabin floor sit the two cargo holds. The forward hold, on aircraft fitted with the option, and the aft hold, can each be ventilated with cabin air, and heated with a little hot bleed air. Keep this picture in mind: the electronics up front, the holds underneath, and the outflow valve at the rear where much of this air ends up.
Part 1 · Avionics ventilation
What it cools and how Fully automatic ; cools the avionics compartment and flight deck equipment, including instrument and circuit-breaker panels Part of the air is always drawn from the cockpit through the panels Two electric fans, blower and extract , run continuously whenever the aircraft is electrically supplied Fan speed controller: high speed above +40 °C , low speed below +35 °C (ventilation air temperature) The AEVC controls all the fans and valves flight deck instrument panels circuit-breaker panels avionics compartment 2 electric fans (blower + extract), AEVC: fully automatic part of the air is always drawn through the panels
Chapter 3 · Ventilation and Cargo
4
e-books by eatpl.in · © 2026 · Do not copy or distribute
The avionics ventilation is fully automatic. It cools the electronic equipment in the avionics compartment, and also the equipment on the flight deck, including the instrument panels and circuit-breaker panels. Whatever configuration the system is in, part of the ventilation air is always sucked from the cockpit through those panels, which is how they stay cool. Two electric fans do the work: a blower fan pushes air into the equipment and an extract fan pulls it out. They run continuously whenever the aircraft has electrical power. A fan speed controller sets their speed by the ventilation air temperature: high speed above plus forty degrees, low speed below plus thirty-five. The gap between forty and thirty-five stops the fans hunting between speeds. All the fans and valves are commanded by one computer, the avionics equipment ventilation controller, or A E V C.
Part 1 · The valves
Six valves, two fans, one skin heat exchanger skin skin SKIN HEAT EXCHANGER AVIONICS EQUIPMENT cockpit panels air cond duct cargo underfloor avionics bay air OVBD skin air inlet valve blower fan extract fan skin air outlet valve skin exch isolation valve skin exch inlet bypass valve skin exch outlet bypass valve air cond inlet valve filter Skin air inlet / outlet : outside air in and out · Isolation : connects the skin heat exchanger · Inlet / outlet bypass : link with the space under the cargo floor · Air cond inlet : fresh air from the packs
Chapter 3 · Ventilation and Cargo
5
e-books by eatpl.in · © 2026 · Do not copy or distribute
Here is the whole network, with every valve drawn open so you can see the paths. Along the main duct, from left to right: the skin air inlet valve admits outside air; a filter and the blower fan push it through the avionics equipment; cockpit panel air joins; the extract fan pulls the warm air out; and the skin air outlet valve throws it overboard. Above, the skin exchange isolation valve connects a loop through the skin heat exchanger, a duct pressed against the cold fuselage skin, back to the blower. The skin exchange inlet and outlet bypass valves let air circulate between the avionics bay and the space under the cargo compartment floor. And underneath, the air conditioning inlet valve can bring in fresh air from the air conditioning system. The A E V C opens and closes these valves to make three normal configurations, and two abnormal ones.
Part 1 · Choosing a configuration
Skin temperature decides AEVC uses ground / flight , thrust levers at T/O and skin temperature Ground threshold: +12 °C rising , +9 °C falling (open ↔ closed) Flight threshold: +35 °C rising , +32 °C falling (closed ↔ intermediate) Two values = hysteresis , so the valves do not cycle Example: skin at +10 °C on the ground: cooling from +20, still open ; warming from +5, still closed On the ground (before T/O power) +0 +5 +10 +15 +20 +25 skin temperature °C +12 °C rising +9 °C falling CLOSED circuit OPEN circuit In flight (and after T/O power) +20 +25 +30 +35 +40 +45 skin temperature °C +35 °C rising +32 °C falling CLOSED circuit INTERMEDIATE
Chapter 3 · Ventilation and Cargo
6
e-books by eatpl.in · © 2026 · Do not copy or distribute
How does the controller choose? It looks at three things: whether the aircraft is on the ground or in flight, whether the thrust levers are at take-off, and the skin temperature. Each decision has two thresholds, one for a rising temperature and one for a falling temperature. On the ground the threshold is plus twelve degrees rising and plus nine falling. In flight it is plus thirty-five rising and plus thirty-two falling. This hysteresis stops the valves cycling when the skin sits right at the threshold. Here is a worked example. On the ground with the skin at plus ten degrees, what configuration are you in? It depends on history. If the skin has cooled from plus twenty, it has not yet dropped below nine, so you are still in open circuit. If it has warmed from plus five, it has not yet reached twelve, so you are still in closed circuit.
Part 1 · Open circuit
Open circuit: outside air straight through skin skin SKIN HEAT EXCHANGER AVIONICS EQUIPMENT cockpit panels air cond duct cargo underfloor avionics bay air OVBD skin air inlet valve blower fan extract fan skin air outlet valve skin exch isolation valve skin exch inlet bypass valve skin exch outlet bypass valve air cond inlet valve filter On the ground , thrust levers not at T/O , skin above the ground threshold (+12 °C rising / +9 °C falling). Skin inlet and outlet open ; everything else closed .
Chapter 3 · Ventilation and Cargo
7
e-books by eatpl.in · © 2026 · Do not copy or distribute
Open circuit is the ground configuration for a warm day. The conditions are: on the ground, thrust levers not at take-off, and the skin temperature above the ground threshold. Watch the flow. The skin air inlet valve opens and outside air comes in, through the filter, and the blower fan pushes it through the avionics equipment. Air from the cockpit panels joins it, and the extract fan pulls the warm air onwards and out through the open skin air outlet valve, overboard. All the other valves are closed. It is simple and very effective while the aircraft is parked. One refinement: even above the threshold, the controller may delay opening the skin valves if the avionics compartment is still too cold, to avoid condensation forming on the equipment. And the moment take-off thrust is set, the system leaves open circuit, because the skin valves must be shut before the aircraft is pressurized.
Part 1 · Closed circuit
Closed circuit: recirculate and cool through the skin skin skin SKIN HEAT EXCHANGER AVIONICS EQUIPMENT cockpit panels air cond duct cargo underfloor avionics bay air OVBD skin air inlet valve blower fan extract fan skin air outlet valve skin exch isolation valve skin exch inlet bypass valve skin exch outlet bypass valve air cond inlet valve filter In flight with skin below +35 °C (rising) / +32 °C (falling), or on the ground below the ground threshold or after T/O power . No air leaves the aircraft.
Chapter 3 · Ventilation and Cargo
8
e-books by eatpl.in · © 2026 · Do not copy or distribute
Closed circuit is the normal flight configuration. It is used in flight while the skin is below the in-flight threshold, and on the ground when the skin is below the ground threshold, or once take-off power has been applied. The skin air inlet valve is closed, and the skin air outlet valve is closed too, so the pressure hull stays sealed. Instead, the skin exchange isolation valve opens. Warm air from the extract fan now goes up into the skin heat exchanger, a duct lying against the cold outer skin, which in cruise is far below zero, and comes back cooled to the blower. The inlet bypass valve also lets some air through to the cargo underfloor area, and the outlet bypass valve draws air back in from the avionics bay, so air mixes between the two. The equipment is cooled without throwing any pressurized air away.
Part 1 · Intermediate configuration
Intermediate: a hot skin in flight In flight , skin temperature above +35 °C (rising)Like closed circuit, but the skin air outlet valve is partially open Some warm air is dumped overboard; the hull is still pressurized Also selected if the skin sensor reads outside −50 to +80 °C , until it is back in range Back to closed circuit once the skin cools below +32 °C Intermediate (flight, hot skin) skin skin SKIN HEAT EXCHANGER AVIONICS EQUIPMENT cockpit panels air cond duct cargo underfloor avionics bay air OVBD Skin air inlet closed Skin air outlet part open Skin exch isolation open Inlet / outlet bypass open / open Air cond inlet closed Blower / extract fan on / on Outlet partially open: a small internal flap only
Chapter 3 · Ventilation and Cargo
9
e-books by eatpl.in · © 2026 · Do not copy or distribute
If the skin itself is warm in flight, the skin heat exchanger cannot cool the air enough. So above plus thirty-five degrees rising, the controller selects the intermediate configuration. It is the closed circuit with one change: the skin air outlet valve is partially open, so some warm air is dumped overboard, while the inlet stays closed. Because the opening is small, the cabin is still pressurized. The system returns to closed circuit when the skin falls below plus thirty-two. There is one more case to remember. The skin temperature sensor measures between minus fifty and plus eighty degrees. If it reads outside that range, the controller does not trust it, and selects the intermediate configuration, partly open, until the reading is back in range. That is a safe middle position whatever the real temperature.
Part 1 · Summary of the logic
Which configuration, when? Situation Skin temperature Configuration Ground, thrust levers not at T/O Above ground threshold (+12 °C rising / +9 °C falling) Open circuit (skin valves may open late to avoid condensation)Ground, thrust levers not at T/O Below ground threshold Closed circuitGround, T/O power applied Any (normal range) Closed circuit (intermediate if skin above flight threshold)Flight Below +35 °C rising / +32 °C falling Closed circuitFlight Above flight threshold Intermediate (outlet partially open)Any Sensor outside −50 … +80 °C Intermediate until back in rangeBLOWER and/or EXTRACT at OVRD — Closed + air conditioning air; both OVRD = smoke configuration DITCHING pb ON — Avionics ventilation inlet and extract valves closed
Chapter 3 · Ventilation and Cargo
10
e-books by eatpl.in · © 2026 · Do not copy or distribute
Here is the whole logic on one page. On the ground before take-off power, the skin temperature decides between open circuit, when it is above the ground threshold, and closed circuit, when it is below. Once take-off power is applied on the ground, and throughout the flight, the system is closed, unless the skin is above the in-flight threshold, in which case it is intermediate. A skin sensor reading outside minus fifty to plus eighty also gives intermediate. The DITCHING pushbutton, from the pressurization panel, closes the avionics inlet and extract valves. Finally, the pushbuttons override everything: one in OVRD gives closed circuit with air conditioning air added, and both in OVRD gives the smoke configuration, which we will see shortly. A simple way to remember it: open only on the ground, never with take-off power; intermediate only when the skin is hot or the sensor is unreliable; and closed the rest of the time.
Part 2 · Crew controls
The VENTILATION panel Normal: both AUTO, lights out VENTILATION BLOWER FAULT OVRD A U T O EXTRACT FAULT OVRD A U T O CAB FANS OFF Avionics smoke: FAULT, then both OVRD VENTILATION BLOWER FAULT OVRD A U T O EXTRACT FAULT OVRD A U T O CAB FANS OFF AUTO : ground before T/O power → open circuit (closed if skin below the ground threshold); after T/O power and in flight → closed circuit.One OVRD : closed circuit + air conditioning air added (BLOWER OVRD also stops the blower fan).Both OVRD : air conditioning air through the equipment and overboard; the extract fan keeps running.
Chapter 3 · Ventilation and Cargo
11
e-books by eatpl.in · © 2026 · Do not copy or distribute
This is the VENTILATION panel on the overhead. The BLOWER and EXTRACT pushbuttons each have an amber FAULT light at the top and a white OVRD legend below. Released, they are in AUTO, and the A E V C runs everything as we have seen: open circuit on the ground before take-off power if the skin is warm, closed circuit after take-off power and in flight. With either pushbutton pressed to OVRD, the system goes to closed circuit and air from the air conditioning system is added to the ventilation air; if it is the BLOWER that is in OVRD, the blower fan also stops. With both at OVRD, air from the air conditioning flows through the equipment and then overboard, and the extract fan keeps running. On the right is the CAB FANS pushbutton, which belongs to air conditioning: it switches the two cabin recirculation fans off when its OFF legend shows. The right-hand drawing shows the smoke case.
Part 2 · FAULT lights
What lights the BLOWER and EXTRACT FAULT lights Each FAULT light is amber and comes with an ECAM alert.
Cause BLOWER FAULT EXTRACT FAULT Blowing pressure low Yes *— Extract pressure low — Yes *Duct overheat Yes *— Computer (AEVC) power supply failure Yes Yes Smoke warning (avionics smoke) Yes Yes
* If this happens on the ground with the engines stopped , the external horn sounds as well, to alert the ground crew.
Chapter 3 · Ventilation and Cargo
12
e-books by eatpl.in · © 2026 · Do not copy or distribute
Learn this table well; it is a classic. The BLOWER FAULT light comes on, amber and with an ECAM alert, if the blowing pressure is low, if the duct overheats, if the computer power supply fails, or if the smoke warning is triggered. The EXTRACT FAULT light comes on if the extract pressure is low, if the computer power supply fails, or if there is a smoke warning. Notice the pattern: each light has its own airflow fault, low pressure on its own side, and the blower alone has the duct overheat; but the two shared causes, a controller power failure and smoke, light both at once. So two FAULT lights together point to smoke or a controller problem. One more detail: for the low pressure and overheat cases, if the aircraft is on the ground with the engines stopped, the external horn sounds too, because there may be no one in the cockpit.
Part 2 · One pushbutton at OVRD
BLOWER or EXTRACT fault: one pushbutton to OVRD System goes to closed circuit and air conditioning air is added (air cond inlet valve opens) BLOWER OVRD : the blower fan stops , the extract fan keeps runningEXTRACT OVRD : the extract fan is controlled directly from the pushbutton ; both fans runSkin inlet and outlet stay closed : nothing is dumped overboard The air conditioning air keeps the equipment cooled BLOWER at OVRD skin skin SKIN HEAT EXCHANGER AVIONICS EQUIPMENT cockpit panels air cond duct cargo underfloor avionics bay air OVBD Skin air inlet closed Skin air outlet closed Skin exch isolation open Inlet / outlet bypass closed / open Air cond inlet open Blower / extract fan OFF / on Air conditioning air replaces the stopped blower
Chapter 3 · Ventilation and Cargo
13
e-books by eatpl.in · © 2026 · Do not copy or distribute
When a BLOWER or EXTRACT FAULT light comes on, the procedure is to set that pushbutton to OVRD. With either one at OVRD, the system goes to closed circuit and opens the air conditioning inlet valve, so fresh air from the air conditioning system is added to the ventilation air. The difference is in the fans. With BLOWER at OVRD, the blower fan stops and the extract fan keeps running; the air conditioning pressure now does the job of the blower. With EXTRACT at OVRD, the extract fan is controlled directly from the pushbutton, bypassing the controller, and both fans continue to run. In both cases the skin inlet and outlet valves stay closed, so nothing is dumped overboard. On the diagram you can see the blower stopped, the air conditioning inlet open, and the air still circulating through the skin heat exchanger to the extract fan.
Part 2 · Avionics smoke
Smoke configuration: both pushbuttons at OVRD skin skin SKIN HEAT EXCHANGER AVIONICS EQUIPMENT cockpit panels air cond duct cargo underfloor avionics bay air OVBD skin air inlet valve blower fan extract fan skin air outlet valve skin exch isolation valve skin exch inlet bypass valve skin exch outlet bypass valve air cond inlet valve filter Smoke detected → BLOWER and EXTRACT FAULT lights. With both at OVRD : air conditioning air → equipment → overboard; blower stops , extract fan runs.
Chapter 3 · Ventilation and Cargo
14
e-books by eatpl.in · © 2026 · Do not copy or distribute
A smoke detector watches the avionics ventilation air. If it detects smoke, both the BLOWER and the EXTRACT FAULT lights come on. When the crew sets both pushbuttons to OVRD, the system takes up the smoke configuration. The air conditioning inlet valve opens, so cabin air from the air conditioning system is pushed into the equipment. The blower fan stops, so it no longer recirculates smoky air. The extract fan keeps running and pulls the air through the equipment, and the skin air outlet valve, with only its small internal flap open, dumps it overboard. The isolation and bypass valves close, so smoke is not spread into the skin loop or the cargo underfloor area. In other words, a one-way flow: clean air in, smoke straight out, with the cabin still pressurized because the outlet opening is so small.
Part 2 · AEVC failure
Controller failure: what each part does If the AEVC fails, the BLOWER and EXTRACT FAULT lights come on, and both pushbuttons are set to OVRD .
Part After a controller failure Blower fan As in the smoke configuration: stopped Skin exchange inlet bypass valve As in smoke configuration: closed Skin air outlet valve As in smoke configuration: partially open (small flap) Skin air inlet valve Frozen in its last positionSkin exchange isolation valve Frozen in its last positionSkin exchange outlet bypass valve Frozen in its last positionExtract fan Keeps running
Chapter 3 · Ventilation and Cargo
15
e-books by eatpl.in · © 2026 · Do not copy or distribute
What if the controller itself fails? Both FAULT lights come on, because a computer power failure lights both, and the crew sets both pushbuttons to OVRD. The result is close to the smoke configuration, but not identical, and examiners like the difference. Three items behave exactly as in smoke: the blower fan stops, the skin exchange inlet bypass valve closes, and the skin air outlet valve goes to its partially open position. Three other valves cannot be commanded any more, so they simply stay where they were when the controller failed: the skin air inlet valve, the skin exchange isolation valve and the skin exchange outlet bypass valve. And the extract fan keeps running. So after a controller failure on the ground in open circuit, the skin inlet valve might still be open; in cruise in closed circuit, the isolation valve would still be open.
Part 2 · ECAM
Avionics ventilation on the ECAM CAB PRESS page Normal flight: closed circuit Avionics smoke, both at OVRD CAB PRESS LDG ELEV AUTO 500 FT ΔP PSI V/S FT/MN CAB ALT FT 0 8 6.9 2 0 2 0 0 10 6200 SYS 1 SAFETY VENT INLET OUTLET PACK 1 PACK 2 TAT +19 °C GW 60300 KG CAB PRESS LDG ELEV AUTO 500 FT ΔP PSI V/S FT/MN CAB ALT FT 0 8 6.9 2 0 2 0 0 10 6200 SYS 1 SAFETY VENT BLOWER EXTRACT INLET OUTLET PACK 1 PACK 2 TAT +19 °C GW 60300 KG VENT white → amber for BLOWER FAULT, EXTRACT FAULT or AVNCS SYS FAULT · BLOWER / EXTRACT appear amber with their fault · INLET / OUTLET white → amber if that valve fails
Chapter 3 · Ventilation and Cargo
16
e-books by eatpl.in · © 2026 · Do not copy or distribute
The avionics ventilation is shown on the CAB PRESS page, inside the fuselage outline, on the left. Normally you see the word VENT in white, with INLET and OUTLET in white beneath it, and a small valve symbol for each on the fuselage line. On the left page, in closed circuit, both symbols show closed, in green. On the right, smoke has been detected and both pushbuttons are at OVRD. The word VENT has turned amber, and BLOWER and EXTRACT have appeared in amber on either side of it. VENT also turns amber for an avionics system fault, A V N C S SYS FAULT. Notice the outlet symbol now shows partially open, the small internal flap of the smoke configuration. The INLET or OUTLET label itself would turn amber only if that valve had failed.
Part 2 · ECAM symbols
Reading the INLET and OUTLET valve symbols Fully closed or fully open : green; amber if the position disagrees with the commandInlet in transit : amber (inlet valve only)Outlet partially open : the valve is closed but a small internal flap is openXX amber: position not available or inconsistentTypical: ground open circuit = both open; flight = both closed; hot skin or smoke = outlet partial fully closed (green; amber if it disagrees) fully open (green; amber if it disagrees) INLET in transit (amber) OUTLET partially open: small internal flap open XX XX amber: position not available INLET / OUTLET labels: white; amber if that valve has failed
Chapter 3 · Ventilation and Cargo
17
e-books by eatpl.in · © 2026 · Do not copy or distribute
The two valve symbols are worth decoding carefully. A valve that is fully closed or fully open is shown in green, and turns amber if its position disagrees with what the controller has commanded. While the inlet valve is moving, it is shown in transit, in amber; only the inlet has this symbol. The outlet has a special symbol of its own: partially open, which really means the main valve is closed but a small internal flap inside it is open. That is the position used in the intermediate and smoke configurations. Finally, if the valve position is not available, or the signals are inconsistent, two amber crosses appear. So, at the gate on a warm day both symbols show open; in cruise both show closed; and with a hot skin or in the smoke configuration the outlet shows partially open.
Part 3 · Other ventilation
Batteries, lavatories and galleys Batteries : a venturi in the aircraft skin draws air from around the batteries and vents it overboard No fan, no valve, no switch: it works with airflow Lavatories and galleys : an extraction fan draws cabin air through themIt exhausts the air near the outflow valve The fan runs continually whenever electrical power is available Batteries BAT BAT venturi in the skin sucks air overboard Lavatories and galleys lavatory galley extraction fan near the outflow valve runs whenever electrical power is on
Chapter 3 · Ventilation and Cargo
18
e-books by eatpl.in · © 2026 · Do not copy or distribute
Two smaller systems complete the ventilation chapter. The batteries sit in their own space, and they need ventilation to carry away any gases. The A320 does this very simply: a venturi in the aircraft skin draws air from the space around the batteries and vents it overboard. There is no fan, no valve and nothing for the crew to operate. The lavatories and galleys need their smells and cooking fumes removed before they reach the cabin. Here an extraction fan draws ambient cabin air through the lavatories and galleys, and exhausts it near the outflow valve, so it leaves the aircraft with the rest of the cabin air. That fan runs continually whenever electrical power is available. Again, there is no control on the overhead panel for either of these: they simply work.
Part 4 · Cargo
Cargo ventilation and heating: the idea FWD hold AFT hold skin venturi, overboard outflow valve cabin air in hot bleed air (aft heating) Ventilation: cabin air pulled through the hold and exhausted. Heating: hot bleed air mixed into that cabin air. Cargo ventilation and heating are customer options: on some aircraft .
Chapter 3 · Ventilation and Cargo
19
e-books by eatpl.in · © 2026 · Do not copy or distribute
The cargo system is simple in principle. To ventilate a hold, an extraction fan draws air out of it and exhausts it, and air from the cabin flows in to replace it. To heat a hold, a little hot bleed air is mixed with that cabin air before it enters, giving the crew control of the hold temperature. The two holds are not identical. Air leaving the forward hold goes overboard through a skin venturi. Air leaving the aft hold goes overboard through the outflow valve, like the rest of the cabin air. The heating on the aft hold uses its own hot air supply, tapped from the bleed system upstream of the packs. These systems are options that vary between aircraft, so on some aircraft you will find only aft ventilation and heating, and on others both holds are equipped.
Part 4 · FWD cargo ventilation
FWD hold: fan on the ground, ΔP in flight Cabin air → inlet isolation valve → hold → outlet isolation valve → skin venturi overboard Ground or ΔP ≤ 1 psi : controller opens the isolation valves, then starts the extraction fanFlight, ΔP > 1 psi : fan stops ; differential pressure drives the flowValves close and fan stops: FWD ISOL VALVE OFF or smoke in the FWD hold DITCHING ON : outlet valve closes and the fan stopscabin (pressurized) cabin floor FWD cargo compartment inlet isolation valve extraction fan outlet isol valve skin venturi → overboard Ground or ΔP ≤ 1 psi valves open, then fan runs Flight, ΔP > 1 psi fan stops; ΔP drives the flow
Chapter 3 · Ventilation and Cargo
20
e-books by eatpl.in · © 2026 · Do not copy or distribute
Let us follow the air through the forward hold, on aircraft that have this option. Air from the cabin, above the floor, enters through the inlet isolation valve into the forward compartment. It leaves through the outlet isolation valve and is discharged overboard by a venturi in the skin. On the ground, or in flight while delta P is one psi or less, the controller opens the isolation valves and then starts the extraction fan, which provides the flow. Now watch the differential pressure gauge. As the cabin pressure climbs through one psi, the controller stops the fan: the pressure difference between cabin and outside now pushes the air through by itself. The controller closes both valves and stops the fan if the crew selects FWD ISOL VALVE to OFF, or if smoke is detected in the forward hold. And, as we saw in pressurization, DITCHING closes the outlet valve and stops the fan.
Part 4 · AFT cargo ventilation
AFT hold: fan always, out via the outflow valve Cabin air → inlet isolation valve → hold → outlet isolation valve → outflow valve Extraction fan runs continuously , ground and flight, when the valves are fully open No ΔP mode: the air leaves with the cabin air through the outflow valveValves close and fan stops: AFT ISOL VALVE OFF or smoke in the AFT hold A cargo ventilation controller runs both valves and the fan cabin (pressurized) AFT cargo compartment inlet isolation valve extraction fan outlet isol valve outflow valve • fan runs continuously , ground and flight, valves fully open • valves close + fan stops: AFT ISOL VALVE OFF or smoke • no ΔP mode: it exits through the outflow valve
Chapter 3 · Ventilation and Cargo
21
e-books by eatpl.in · © 2026 · Do not copy or distribute
The aft hold works in a similar way, with one important difference. Cabin air enters through the inlet isolation valve, crosses the aft hold, and is drawn by an extraction fan through the outlet isolation valve. But instead of a skin venturi, the air then goes out through the outflow valve, together with the rest of the cabin air. Because it does not exhaust directly to the outside, differential pressure cannot drive it on its own, so when the isolation valves are fully open, the extraction fan runs continuously, on the ground and in flight. The cargo ventilation controller runs the valves and the fan. It closes both isolation valves and stops the fan if the crew selects AFT ISOL VALVE to OFF, or if the aft cargo smoke detection detects smoke. The comparison is a favourite question: forward fan stops above one psi, aft fan always runs.
Part 4 · Cargo heating
How the aft hold is heated hot bleed air (upstream of the packs) cargo pressure regulating valve cargo trim air valve cabin ambient air mix inlet isolation valve AFT cargo compartment inlet temp compartment temp cargo heating controller • AFT selector: COLD ≈ 5 °C, middle ≈ 15 °C, HOT ≈ 26 °C • modulates the trim air valve • inlet > 70 °C: trim air valve closes • inlet ≥ 88 °C: duct overheat, press reg valve closes, FAULT • reset (HOT AIR pb) below 70 °C FWD hold (where fitted) uses the cockpit and cabin hot air press reg valve, then a cargo trim air valve; same 70 / 88 °C logic The cargo pressure regulating valve sets the hot air pressure ; the cargo trim air valve sets the flow . HOT AIR OFF closes both; ISOL VALVE OFF closes the trim air valve.
Chapter 3 · Ventilation and Cargo
22
e-books by eatpl.in · © 2026 · Do not copy or distribute
Here is the aft heating in detail. Hot engine bleed air is tapped upstream of the packs. It first passes the cargo pressure regulating valve, which is pneumatically operated and electrically controlled from the HOT AIR pushbutton on the CARGO HEAT panel; it regulates the pressure of the hot air. Next comes the cargo trim air valve, modulated electrically by the controller, which sets how much hot air flows. The hot air mixes with cabin air, and the mixture enters the hold through the inlet isolation valve. The controller compares the temperature sensors with the AFT selector and adds hot air until the selected temperature is reached. On aircraft with forward heating, the forward hold works the same way, but its hot air comes through the cockpit and cabin hot air pressure regulating valve used for zone temperature control, and it has its own cargo trim air valve.
Part 4 · Duct overheat
70 °C and 88 °C: the overheat logic Inlet temperature above 70 °C : the controller closes the trim air valve At 88 °C : duct overheat ; the pressure regulating valve closes ; HOT AIR FAULT + ECAM caution ECAM duct inlet temperature turns amber at 80 °C The valve stays closed until the crew resets : only possible below 70 °C Reset: HOT AIR OFF (FAULT goes out below 70 °C), then back on 70 °C 80 °C 88 °C 30 40 50 60 70 80 90 duct inlet temperature °C → time (minutes, illustrative) 1 2 3 4 1 trim air valve closes 2 ECAM inlet temp amber 3 PRV closes, HOT AIR FAULT + ECAM 4 below 70: HOT AIR OFF, then ON = reset
Chapter 3 · Ventilation and Cargo
23
e-books by eatpl.in · © 2026 · Do not copy or distribute
The cargo heating has two temperature limits on the duct inlet. Follow the worked example on the graph. The inlet temperature is climbing. At point one, above seventy degrees, the controller closes the trim air valve to stop adding hot air. Suppose it keeps climbing anyway, for example because hot air is leaking past. At point two, eighty degrees, the inlet temperature on the ECAM COND page turns amber. At point three, eighty-eight degrees, the controller declares a duct overheat and closes the pressure regulating valve, cutting the hot air at its source; the HOT AIR FAULT light and an ECAM caution come on. The valve now stays closed until the crew resets the system, and that is only possible once the temperature is below seventy. At point four, the crew selects HOT AIR to OFF, the FAULT light goes out, and pressing it again resets the system.
Part 4 · Crew controls
The CARGO HEAT panel CARGO HEAT FWD ISOL VALVE FAULT OFF FWD COLD HOT HOT AIR FAULT OFF AFT ISOL VALVE FAULT OFF AFT COLD HOT FWD / AFT ISOL VALVE Auto: inlet + outlet valves open, fan runs (no smoke) OFF: valves + trim air valve close, fan stops; FAULT: valve disagrees HOT AIR Auto: press reg valve regulates; OFF: PRV + trim valve close, resets FAULT: duct overheat 88 °C; out below 70 °C with OFF Temperature selectors COLD ≈ 5 °C · 12 o’clock ≈ 15 °C · HOT ≈ 26 °C bulk hold may be up to 10 °C colder than selected
Chapter 3 · Ventilation and Cargo
24
e-books by eatpl.in · © 2026 · Do not copy or distribute
This is the CARGO HEAT panel, here in its fullest version, with both holds equipped. On the left are the forward controls: the FWD ISOL VALVE pushbutton and the FWD temperature selector. On the right: the HOT AIR pushbutton, the AFT ISOL VALVE pushbutton and the AFT temperature selector. Each ISOL VALVE pushbutton in auto opens the inlet and outlet isolation valves and lets the extraction fan run, provided no smoke is detected; at OFF it closes those valves and the trim air valve and stops the fan. Its amber FAULT light, with an ECAM caution, means an isolation valve is not in the selected position. HOT AIR in auto lets the pressure regulating valve regulate; at OFF it closes the pressure regulating valve and the trim air valve, and resets the fault circuit. The selectors give about five degrees at COLD, fifteen in the middle and twenty-six at HOT, though the bulk hold may be up to ten degrees colder.
Part 4 · ECAM COND page
Cargo on the ECAM COND page: normal and overheat Normal: aft hold heated Duct overheat, HOT AIR OFF COND TEMP : °C CKPT 22 20 C H FWD 23 21 C H AFT 24 22 C H HOT AIR AFT 15 18 C H HOT AIR COND TEMP : °C CKPT 22 20 C H FWD 23 21 C H AFT 24 22 C H HOT AIR AFT 15 85 C H HOT AIR Inlet isolation valve: in line green = open , cross-line amber = closed. Outlet isolation valve: the other way round, cross-line green = open , in line amber = closed.
Chapter 3 · Ventilation and Cargo
25
e-books by eatpl.in · © 2026 · Do not copy or distribute
The cargo indications are at the bottom of the COND page. The box labelled AFT, in white, has the compartment temperature next to it in green. Below are the duct inlet temperature, green normally and amber from eighty degrees, the inlet isolation valve, the trim air valve with its C and H scale, and the hot air pressure regulating valve. On the left page everything is normal. On the right there has been a duct overheat and the crew has selected HOT AIR to OFF: the inlet temperature, eighty-five, is amber; the trim air valve needle is at C, closed; and the hot air valve shows cross-line in amber, meaning closed with the pushbutton OFF. Cross-line in green would mean closed normally with the pushbutton on, and in line amber would mean failed open. A small trap: for the inlet isolation valve, in line means open, but the outlet isolation valve symbol is the other way round.
Exam traps
Classic ventilation and cargo traps Open circuit = ground only Open circuit needs ground , no T/O power and skin above +12 / +9 °C . In flight it is closed or intermediate.
Two FAULT lights together Both BLOWER and EXTRACT FAULT = smoke or controller power failure . Low pressure lights only one.
BLOWER vs EXTRACT OVRD BLOWER OVRD stops the blower . EXTRACT OVRD runs the extract fan from the pb ; both fans run.
Smoke vs controller failure Failure: blower, inlet bypass and outlet as in smoke; inlet, isolation, outlet bypass frozen .
FWD vs AFT cargo fan FWD fan stops above 1 psi (venturi). AFT fan always runs (out via the outflow valve).
70 / 80 / 88 °C 70: trim air valve closes and reset limit · 80: ECAM amber · 88: PRV closes, FAULT.
Chapter 3 · Ventilation and Cargo
26
e-books by eatpl.in · © 2026 · Do not copy or distribute
Here are the traps. Open circuit is a ground-only configuration, and only before take-off power with a warm skin; in flight you are always closed or intermediate. Two FAULT lights together mean smoke or a controller power failure, never a simple low-pressure fault, which lights only its own pushbutton. BLOWER to OVRD stops the blower fan; EXTRACT to OVRD runs the extract fan directly from the pushbutton and keeps both fans running. After a controller failure, the blower, inlet bypass valve and outlet valve behave as in smoke, but the inlet, isolation and outlet bypass valves stay frozen. In the cargo, the forward fan stops above one psi because the venturi and delta P do the work, while the aft fan always runs. And keep the three temperatures apart: seventy closes the trim air valve and is the reset limit, eighty turns the ECAM amber, and eighty-eight closes the pressure regulating valve.
Summary
Ventilation and cargo on one page Avionics parts AEVC; blower + extract fans (FSC: high > 40, low < 35 °C); skin inlet/outlet, isolation, inlet/outlet bypass, air cond inlet valves.
Configurations Open: ground, no T/O power, skin > +12/+9 °C. Closed: flight or cold skin or T/O power. Intermediate: skin > +35/+32 °C or sensor out of range.
Abnormal One OVRD: closed + air cond air. Both OVRD: smoke config, air cond air overboard, blower off, extract on.
ECAM VENT white → amber; BLOWER / EXTRACT amber; INLET / OUTLET symbols: open, closed, transit, partial, XX.
Batteries, lav, galley Battery: skin venturi overboard. Lav/galley: extraction fan, always on with power, exhausts near the outflow valve.
Cargo ventilation FWD: fan if ground or ΔP ≤ 1 psi, venturi out. AFT: fan always, out via outflow valve. OFF or smoke closes valves.
Cargo heating Hot bleed + cabin air. PRV (HOT AIR pb) + trim air valve. 70 °C trim closes; 88 °C PRV closes; reset < 70 °C.
Panel FWD/AFT ISOL VALVE (FAULT/OFF), HOT AIR (FAULT/OFF), selectors ≈ 5 / 15 / 26 °C; hold up to 10 °C colder.
Chapter 3 · Ventilation and Cargo
27
e-books by eatpl.in · © 2026 · Do not copy or distribute
To sum up. The avionics ventilation is run by the A E V C with a blower and an extract fan and six valves. On the ground before take-off power, a warm skin gives open circuit; otherwise the system is closed, using the skin heat exchanger, or intermediate when the skin is hot or the sensor is out of range. One pushbutton at OVRD adds air conditioning air in closed circuit; both at OVRD give the smoke configuration, with air conditioning air going through the equipment and overboard. On the ECAM, watch VENT, BLOWER, EXTRACT and the two valve symbols. Batteries are vented by a skin venturi, and lavatories and galleys by an extraction fan near the outflow valve. In the cargo, the forward fan stops above one psi, the aft fan always runs, and heating mixes hot bleed air with cabin air, protected at seventy and eighty-eight degrees. Learn the panel and you are ready.