Welcome to water and waste, a short chapter, but one that comes up in interviews more often than you would think. Where is the water tank? What pushes the water to the taps when there is no pump? Why does a vacuum toilet need a fan on the ground but not at cruise altitude? And what can the cabin crew do when a basin leaks or a toilet will not flush? In this lesson we will follow the water from the tank to the galleys and lavatories, then follow the wastewater overboard through the drain masts, and the toilet waste into the waste tank, and finish with the controls on the forward attendant panel and the servicing points.
Lesson roadmap
Water and waste in three parts ATA 38 . Three jobs: distribute potable water, dispose of wastewater, store toilet waste.
1 · Potable water The tank , its pressurisation by air, distribution and the manual shut-off valves .
2 · Wastewater Galley and basin water overboard through two heated drain masts .
3 · Toilets The vacuum system, the 170 L waste tank , the 16 000 ft logic, controls, faults and servicing.
Chapter 29 · Water and Waste
2
e-books by eatpl.in · © 2026 · Do not copy or distribute
This lesson has three parts, matching the three jobs of the system. First, potable water: where the tank is, how it is pressurised, since there is no water pump, how the water reaches the galleys and lavatories, and how the crew can isolate a leaking outlet with the manual shut-off valves. Second, wastewater, the water from the washbasins and galleys, which is simply thrown overboard through two heated drain masts. Third, the toilets: the vacuum system that moves the waste into the waste tank, why it needs a vacuum generator only on the ground and at low altitude, how it is controlled and monitored, and what to do when something fails. All the controls are on the forward attendant panel in the cabin, not in the cockpit.
Overview
Where the water and waste systems are FWD cargo AFT cargo water tank (later aircraft): ahead of the wing box earlier aircraft: aft cargo, left wall FWD drain mast heated AFT drain mast heated FAP controls: FAP Galleys and lavatories in the cabin are fed with potable water; their wastewater drains overboard, toilet waste goes to a waste tank. Servicing: water and waste service panels under the fuselage Controls on the forward attendant panel (FAP) in the cabin · all lines insulated against leaks and ice
Chapter 29 · Water and Waste
3
e-books by eatpl.in · © 2026 · Do not copy or distribute
Let us place the system on the aircraft. On later aircraft, the potable water tank sits under the floor, just in front of the wing box, behind the forward cargo hold. On earlier aircraft it is in the left-hand wall of the aft cargo hold. From the tank, water lines run to the galleys and lavatories in the cabin. Underneath the fuselage are two drain masts, one forward and one aft, which throw the wastewater from the basins and galleys overboard. The toilet waste goes into a waste tank instead. The whole system is insulated, to prevent leaks and stop ice building up in the lines. And notice where the controls are: on the forward attendant panel, in the cabin.
Part 1 · Potable water
The water tank and its air Tank: 200 L (or 135 L on some earlier aircraft) Later aircraft: ahead of the wing box , behind the FWD cargo hold; earlier: aft cargo, left wall No pump: the water is pushed by air pressure Ground: air from the service panel pressure port (or an air-supply boost system) Flight: bleed air Storing and pressurising the water 200 L (135 L on some earlier aircraft) Later aircraft: ahead of the wing box, behind the FWD cargo hold Earlier aircraft: aft cargo hold, left wall On the ground air from the service panel pressure port, or from the air-supply boost system In flight bleed air pushes the water from the tank to every outlet Water quantity: on the FAP and on the aft service panel Fill and drain: at the service panel under the fuselage All lines insulated against leaks and ice
Chapter 29 · Water and Waste
4
e-books by eatpl.in · © 2026 · Do not copy or distribute
The potable water tank holds two hundred litres, or one hundred and thirty-five on some earlier aircraft. There is no water pump on the A320. Instead the tank is pressurised with air, and that air pressure pushes the water out to every tap and toilet. On the ground, the air comes from the service panel pressure port, where ground equipment can be connected, or from an air-supply boost system on aircraft that have one. In flight, the tank is pressurised with bleed air. So if you ever wonder why the taps still work in cruise, the answer is bleed air. The quantity of water in the tank is shown on the forward attendant panel and on the aft service panel, and the tank is filled and drained from the service panel under the fuselage.
Part 1 · Distribution
From the tank to the galleys and lavatories FWD lavatory washbasin, toilet flush FWD galleys wet galley MID lavatory washbasin, toilet flush AFT lavatory washbasin, toilet flush AFT galleys wet galley manual shut-off valves OPEN / SHUT WATER TANK bleed air (flight) ground: pressure port / boost water service panel (under the fuselage) drain fill overflow ground pressurisation port quantity indication → FAP Manual shut-off valves under the washbasins or toilet bowls, marked OPEN / SHUT · fill, drain and overflow at the service panel
Chapter 29 · Water and Waste
5
e-books by eatpl.in · © 2026 · Do not copy or distribute
Here is the potable water system as a schematic. One supply line from the pressurised tank runs along the cabin and feeds the forward lavatory, the forward galleys, a mid lavatory on some aircraft, the aft lavatory and the aft galleys. Each lavatory and each wet galley has its own manual shut-off valve, located under the washbasin or the toilet bowl, with a legend showing OPEN or SHUT. Below the tank, at the water service panel under the fuselage, are the connections for servicing: a fill port, an overflow, a drain valve and port, and the ground pressurisation port that we just saw. The quantity indicator is there too, and its reading is repeated on the forward attendant panel, so the cabin crew can check the water before departure.
Part 1 · Shut-off valves
Isolating a leaking outlet Valves isolate the wet galleys , the FWD (or MID) and the AFT lavatory Located under the washbasin or the toilet bowl Position shown by an OPEN / SHUT legend Only the isolated outlet loses water An inoperative toilet is also isolated by a manual shut-off valve Worked example: a leak at a washbasin FWD lavatory manual shut-off valve under the basin: turned to SHUT galleys and other lavatories keep water 1 · cabin crew find the leak in the forward lavatory 2 · close that lavatory's manual shut-off valve (SHUT) 3 · only that outlet loses water; galleys and other lavatories are still supplied 4 · report it; maintenance sees the defect Valves isolate wet galleys, the FWD (or MID) and the AFT lavatory. Each shows OPEN or SHUT.
Chapter 29 · Water and Waste
6
e-books by eatpl.in · © 2026 · Do not copy or distribute
The manual shut-off valves are the cabin crew's tool against leaks. Let us work through an example. In cruise, an attendant finds water running from the washbasin in the forward lavatory. Under the basin is that lavatory's manual shut-off valve, with a legend showing OPEN or SHUT. She turns it to SHUT. Now only the forward lavatory loses its water supply: the galleys and the other lavatories are still fed, because each outlet has its own valve. The defect is reported so maintenance can fix it. The valves isolate the wet galleys, the forward lavatory, or the mid lavatory where fitted, and the aft lavatory. The toilet system has the same idea: an inoperative toilet is isolated with its own manual shut-off valve.
Part 2 · Wastewater
Overboard through the drain masts Wastewater from galleys and lavatory basins goes overboard Two heated drain masts : FWD for the forward cabin, AFT for the aft cabin On the ground: gravity In flight: differential pressure Heating stops the water freezing in the masts Wastewater: overboard through two masts FWD galley FWD lav AFT lav AFT galley FWD mast: forward cabin AFT mast: aft cabin On the ground gravity In flight differential pressure Masts are heated, so the water does not freeze in them.
Chapter 29 · Water and Waste
7
e-books by eatpl.in · © 2026 · Do not copy or distribute
Wastewater is the used water from the galley sinks and the lavatory washbasins. It is not stored: it drains overboard through two drain masts under the fuselage. The forward mast takes the water from the forward part of the cabin, the aft mast from the aft part. What makes it flow? On the ground, simply gravity: the masts are at the bottom of the fuselage. In flight, the cabin is pressurised, so the differential pressure between the cabin and the outside air pushes the water out. Outside air in flight is far below freezing, so the drain masts are heated. Without heating, the water would freeze in the mast, block it, and the drains would back up.
Part 3 · Toilet system
Vacuum toilets and the waste tank FWD toilet rinse water MID (some a/c) rinse water AFT toilet rinse water flush valve WASTE TANK 170 L usable drain valve vacuum generator air out tank rinse line waste service panel under the fuselage: draining, rinsing How waste moves differential pressure pulls it from the bowl to the tank Ground and below 16 000 ft the vacuum generator makes the ΔP Above 16 000 ft cabin-to-outside ΔP alone is enough Flushing clean water from the potable system Control one flush control unit per toilet; the VSC Differential pressure moves the waste · vacuum generator on the ground and in flight below 16 000 ft · flush water from the potable system
Chapter 29 · Water and Waste
8
e-books by eatpl.in · © 2026 · Do not copy or distribute
The toilets do not drain overboard. They are vacuum toilets. When a passenger presses flush, the flush valve under the bowl opens to the waste line, and the difference in pressure between the cabin and the waste tank sucks the contents along the pipe into the waste tank. The waste tank has a usable capacity of one hundred and seventy litres. Clean water from the potable water system rinses the bowl during the flush. Where does the pressure difference come from? In flight at altitude, the difference between the cabin pressure and the outside pressure does the job. But on the ground, and in flight below sixteen thousand feet, that difference is too small, so a vacuum generator pulls air out of the waste tank to create it. The tank is drained and rinsed from the waste service panel.
Part 3 · The 16 000 ft logic
When the vacuum generator runs Ground : vacuum generatorFlight below 16 000 ft : vacuum generatorAbove 16 000 ft : cabin differential pressure aloneExample: climb to FL 350 in 22 min: generator stops after about 10 min Descent from minute 100 to 125: it restarts at about minute 113.6 Worked example: when does the vacuum generator run? 16 000 ft 0 10 20 30 x1000 ft 0 30 60 90 120 minutes ON ON OFF: ΔP does the work 10 min 113.6 min Climb 0 → 35 000 ft in 22 min: 16 000 ft after about 10 min Descent 35 000 → 0 ft from minute 100 to 125: 16 000 ft after about 13.6 min, at minute 113.6 Vacuum generator: ground, 0–10 min, then 113.6 min to the gate
Chapter 29 · Water and Waste
9
e-books by eatpl.in · © 2026 · Do not copy or distribute
Let us check when the vacuum generator runs, with a simple flight profile. We take off at minute zero and climb steadily to thirty-five thousand feet in twenty-two minutes. Sixteen thousand feet is sixteen thirty-fifths of the climb, so we pass it after about ten minutes. Up to then, the vacuum generator runs. Above it, the differential pressure between the cabin and the outside is large enough to move the waste, and the generator is no longer needed. We start down at minute one hundred and land at minute one hundred and twenty-five. Sixteen thousand feet is reached after nineteen thirty-fifths of the twenty-five minute descent, about thirteen point six minutes, so at minute one hundred and thirteen point six. From there, through landing and taxi to the gate, the vacuum generator runs again.
Part 3 · Control and monitoring
Flush control units and the VSC FLUSH pb in each toilet Flush control unit one per toilet: the flush sequence Vacuum system controller VSC: control, monitoring, faults FAP waste tank level, defects CFDS defects for maintenance water valve rinse water flush valve bowl to waste line vacuum generator on / off tank level sensors tank pressure sensors service panel status Electrical flush valve failure: use the manual flush control under the bowl. Toilet inoperative: isolate it with its manual shut-off valve.
Chapter 29 · Water and Waste
10
e-books by eatpl.in · © 2026 · Do not copy or distribute
How is it all controlled? Each toilet has its own flush control unit, which runs the flush sequence when the flush pushbutton is pressed: it opens the rinse water valve and the flush valve, and runs the vacuum generator when it is needed. Above them sits the vacuum system controller, the V S C. It looks after control, monitoring and fault reporting for the whole system. It reads the tank level sensors, the tank pressure sensors and the service panel. It sends the waste tank level and any system defects to the forward attendant panel, so the cabin crew can see them, and it reports defects to the centralized fault display system, the C F D S, for the maintenance engineers. So the waste tank level and any toilet fault show up in the cabin, and the faults also reach maintenance.
Part 3 · When things go wrong
Faults and what the crew can do Leaking basin or galley Close that outlet's manual shut-off valve (SHUT). Other outlets keep their water.
Toilet inoperative Isolate it with its manual shut-off valve ; the other toilets keep working.
Flush valve electrical failure Use the manual flush control , located under each toilet bowl .
System defect The VSC reports it on the FAP (with the waste tank level) and to the CFDS for maintenance.
Chapter 29 · Water and Waste
11
e-books by eatpl.in · © 2026 · Do not copy or distribute
Here are the cases you may be asked about. A leaking washbasin or galley tap: close the manual shut-off valve for that outlet, and the others keep their water. A toilet that is not working, for example a blocked bowl: isolate that toilet with its manual shut-off valve, and the other toilets keep working, because each has its own flush control unit. A flush valve whose electrical drive has failed: there is a manual flush control under each toilet bowl, so the toilet can still be used. And for any system defect, the vacuum system controller reports it on the forward attendant panel, together with the waste tank level, and sends it to the centralized fault display system for maintenance. Notice that these are essentially cabin and maintenance items, handled at the FAP and by the cabin crew.
Part 3 · Servicing
Who sees what, and where it is serviced Item Where Notes Water and waste controls Forward attendant panel (FAP) In the cabin Water quantity FAP and the aft service panel Check before departure Waste tank level, system defects FAP (from the VSC)Defects also to the CFDS Fill and drain potable water Service panel under the fuselage Fill, overflow and drain connections Ground pressurisation of the water Service panel pressure port Or the air-supply boost system Waste tank servicing Waste service panel under the fuselage Drain valve and tank rinse line
Chapter 29 · Water and Waste
12
e-books by eatpl.in · © 2026 · Do not copy or distribute
This table pulls together who sees what and where the system is serviced. The controls of both the water and the waste systems are on the forward attendant panel, the FAP, in the cabin. The water quantity is shown on the FAP and on the aft service panel. The waste tank level and any system defects are shown on the FAP by the vacuum system controller, and defects also go to the centralized fault display system. On the ground, the potable water is filled and drained at the service panel under the fuselage, and the water system can be pressurised through the service panel pressure port, or by the air-supply boost system. The waste tank is emptied and rinsed by the ground crew through a waste service panel, also under the fuselage.
Summary
Water and waste on one page Potable water Tank 200 L (135 L some earlier a/c), ahead of the wing box (later) or aft cargo left wall (earlier). Pushed by air: ground pressure port / boost , bleed air in flight .
Distribution Galleys and lavatories; manual shut-off valves under basins and bowls, OPEN / SHUT. Quantity on the FAP and aft service panel.
Wastewater Overboard through two heated drain masts , FWD and AFT. Gravity on the ground, ΔP in flight.
Toilets Vacuum: ΔP moves the waste to a 170 L tank. Vacuum generator on the ground and below 16 000 ft . Flush with potable water.
Control One flush control unit per toilet. VSC : control, monitoring, faults → FAP and CFDS .
Faults Leak or dead toilet: manual shut-off valve . Flush valve electrical failure: manual flush control under the bowl.
Chapter 29 · Water and Waste
13
e-books by eatpl.in · © 2026 · Do not copy or distribute
Let us sum up. The potable water tank holds two hundred litres, or one hundred and thirty-five on some earlier aircraft. It sits ahead of the wing box on later aircraft, or in the aft cargo hold on earlier ones, and the water is pushed by air: from the ground pressure port or boost system on the ground, and bleed air in flight. Each galley and lavatory has a manual shut-off valve. Wastewater from basins and galleys goes overboard through two heated drain masts, by gravity on the ground and differential pressure in flight. The vacuum toilets send their waste to a one hundred and seventy litre tank, with a vacuum generator on the ground and below sixteen thousand feet. Each toilet has a flush control unit, the vacuum system controller reports to the FAP and the CFDS, and the cabin crew can isolate a toilet or flush it manually.