Aircraft Systems · Chapter 12
Air Conditioning How hot bleed air becomes cool, dry, fresh cabin air: the air cycle machine, heat exchangers, water separators, temperature and zone control, recirculation and the vapour cycle.
Primary HX Comp- ressor Secondary HX Turbine common shaft: the turbine drives the compressor 200 °C 64 °C 108 °C 46 °C -8 °C Cool, dry, fresh air for the cabin © 2026 eatpl.in. For the personal study of eatpl.in students only. Do not copy or distribute.
e-books by eatpl.in · © 2026 · Do not copy or distribute
Chapter twelve is about air conditioning. Bleed air arrives from the engines at around two hundred degrees, and the passengers want it at about twenty two degrees, fresh, not too dry and not too wet, at a steady flow. How does an aircraft do that, when the outside air at altitude is at minus fifty and on a summer runway at plus forty? We will look at the cabin air requirements, then at the air cycle machine, the clever turbine and compressor that does most of the cooling, and at the heat exchangers, ram air system and water separator around it. Then temperature control, zone trim, distribution and recirculation, and finally the vapour cycle, the refrigerator of the air.
Roadmap
From 200 °C bleed to a comfortable cabin 1 · Requirements Fresh air per seat, temperature, humidity, contamination, duplication.
2 · Air cycle cooling Bootstrap, brake turbine and turbo-fan cold air units; the numbers through a pack.
3 · Pack components Heat exchangers, ram air doors, ground fan, water separator, humidifier.
4 · Control Mass flow controller and temperature control: automatic and manual.
5 · Distribution Risers and outlets, gasper air, zone trim, recirculation fans.
6 · Vapour cycle The refrigerator: compressor, condenser, receiver, expansion valve, evaporator.
Exam focus The order of components in a bootstrap pack and in a vapour cycle, and what each one does.
Links Lesson 11 supplied the bleed air; lesson 13 uses this air to pressurise.
Chapter 12 · Air Conditioning
2
e-books by eatpl.in · © 2026 · Do not copy or distribute
Here is the plan. We start with what the cabin air must achieve: how much fresh air per seat, what temperature and humidity, and how clean. Then the heart of the lesson, air cycle cooling. You will meet the bootstrap cold air unit, the most common on jets, and its cousins the brake turbine and the turbo-fan, and we will put real numbers on the air as it passes through a pack. Third, the components around it: heat exchangers, the ram air doors, the ground cooling fan, the water separator and the humidifier. Fourth, the controls: mass flow and temperature. Fifth, how the air is distributed, with gaspers, zone trim and recirculation. And finally the vapour cycle, a refrigerator in the aircraft. In the exam, the order of the components in each machine is a favourite, so watch the sequence carefully.
Part 1 · Requirements
What the cabin air must achieve Item Requirement Fresh air 1 lb per seat per minute normally; not less than 0.5 lb after a failure in the duplicated systemCrew Not less than 10 cubic feet per minute per crew member Temperature 18 to 24 °C (65 to 75 °F)Relative humidity About 30 % (outside air at 40 000 ft is only about 1 to 2 %) Contamination Carbon monoxide not more than 1 part in 20 000 Ventilation Adequate on the ground and in unpressurised flight Duplication No single failure may drop fresh air below 0.5 lb per seat per minute
Large aircraft therefore carry two packs: either one alone can meet the minimum.
Chapter 12 · Air Conditioning
3
e-books by eatpl.in · © 2026 · Do not copy or distribute
These are the requirements an air-conditioning system must meet, and the numbers are popular in exams. Fresh air must be supplied at one pound per seat per minute in normal operation, and at not less than half a pound per seat per minute after the failure of any part of the duplicated system. Each crew member must get at least ten cubic feet per minute. The cabin temperature should be kept between eighteen and twenty four degrees Celsius, sixty five to seventy five Fahrenheit. Relative humidity should be around thirty per cent, compared with only one or two per cent in the outside air at forty thousand feet. Carbon monoxide must not exceed one part in twenty thousand. There must be adequate ventilation on the ground and in unpressurised flight. And the system must be duplicated, so that no single failure drops the fresh air below half a pound per seat per minute. That is why airliners have two packs.
Part 1 · Conditioned air
How the requirements are met Conditioned air : its temperature, humidity and pressure adjusted for peopleSupply: a constant mass flow , enough to pressurise at maximum operating altitude Temperature: hot and cold air mixed in variable proportions Humidity: moisture removed (water separator) or added (humidifier) The same air then pressurises the cabin (lesson 13) What "conditioned" means Mass flow constant, set by the flow control valve Temperature cool in the pack, then mix with hot air Humidity water separator removes; humidifier may add Pressure cabin pressure set by the outflow valve bleed air in to the cabin Conditioned air: temperature, humidity and pressure adjusted for people
Chapter 12 · Air Conditioning
4
e-books by eatpl.in · © 2026 · Do not copy or distribute
So how are these requirements met? The air coming out of the system is called conditioned air: air whose temperature, humidity and pressure have been adjusted to make it suitable for people in the cabin. First, the supply. The mass flow into the cabin is held at a constant value, and that value must be big enough to pressurise the cabin when cruising at the maximum operating altitude, where leaks are greatest. Second, temperature. The air is cooled in the pack, and then hot and cold air are mixed in variable proportions to give the temperature the crew have selected. Third, humidity. On a humid day low down, water is removed by the water separator; on long flights at high altitude, some aircraft add moisture with a humidifier. And this same conditioned air is what pressurises the cabin, as we will see in the next lesson.
Part 2 · The cooling problem
Why a heat exchanger is not enough Bleed air arrives at about 200 °C ; the cabin wants about 22 °C Passengers, sunshine, galleys and avionics add heat: the cabin needs cooling even in the cruise A heat exchanger can only approach the cooling air temperature , never go below it On a 40 °C day an 80 % exchanger leaves the air at about 72 °C So a cold air unit (air cycle) or a refrigerant (vapour cycle) is needed A heat exchanger alone is not enough -40 0 40 80 120 160 200 °C +200 Bleed +16 After HX cruise +72 After HX hot day +22 Cabin wanted -8 Pack outlet ambient 40 °C A heat exchanger can never get below the cooling air temperature
Chapter 12 · Air Conditioning
5
e-books by eatpl.in · © 2026 · Do not copy or distribute
Why do we need a machine to cool the air at all, when the outside air at altitude is so cold? Bleed air arrives at around two hundred degrees, and the cabin wants about twenty two. A heat exchanger, cooled by ram air, gets rid of a lot of that heat. But a heat exchanger has a fundamental limit: it can bring the hot air close to the temperature of the cooling air, but never below it. In the cruise at minus thirty outside, an eighty per cent effective exchanger gives about sixteen degrees, which is useful. But on the ground on a forty degree day, the same exchanger can only get down to about seventy two degrees. And the cabin, full of people, sunshine, galley ovens and electronics, actually needs air colder than twenty two to carry its heat away. So we need a way to get below the outside air temperature: a cold air unit using the air cycle, or a refrigerant in a vapour cycle.
Part 2 · Air cycle cooling
Three kinds of cold air unit The air cycle cools by energy conversion : compressed air does work turning a turbine, and loses heat as it expands. It is preferred on most jet transports.
Turbo-compressor (bootstrap) Turbine drives a compressor in the charge air line. Works with LOW bleed pressure: high-bypass engines and small turboprops. The most common.
Brake turbine Higher bleed pressure straight to the turbine; the turbine drives a compressor of ambient air through a restriction. Light, one heat exchanger; no ground cooling without a jet pump.
Turbo-fan The turbine drives a fan that pulls cooling air through the heat exchanger: no ram air needed, so it cools on the ground. Light and compact.
Chapter 12 · Air Conditioning
6
e-books by eatpl.in · © 2026 · Do not copy or distribute
Air cycle cooling is the preferred method on most jet transport aircraft. It works by energy conversion: compressed air is made to do work, spinning a turbine, and as it expands through the turbine it gives up energy and leaves much colder. The heart of the system is the cold air unit, and there are three basic types. The turbo-compressor, better known as the bootstrap, has the turbine driving a compressor in the charge air line itself; it works with low bleed pressures, so it suits aircraft with high bypass engines or small turboprops, and it is by far the most common. The brake turbine takes higher pressure air straight to the turbine, which drives a compressor of outside air through a restriction. And the turbo-fan has the turbine driving a fan, which pulls cooling air through the heat exchanger, so it does not depend on ram air and can cool on the ground.
Part 2 · The bootstrap pack
Bootstrap cold air unit: pre-cool, compress, cool, expand Primary heat exchanger Compressor Secondary heat exchanger Turbine Water separator to mix common shaft: the turbine drives the compressor ram air overboard 200 °C 64 °C 108 °C 46 °C -8 °C Air cycle machine (bootstrap): pre-cool, compress, cool again, expand
Chapter 12 · Air Conditioning
7
e-books by eatpl.in · © 2026 · Do not copy or distribute
Here is the bootstrap pack, the most popular air cycle system in use. Follow the air. Hot bleed air at about two hundred degrees enters the primary heat exchanger, where ram air cools it to about sixty four. Next it goes to the compressor of the cold air unit, which raises its pressure, and with it its temperature, to well over a hundred. That heat is removed in the secondary heat exchanger, also cooled by ram air, bringing it down to the forties. Now the high-pressure, fairly cool air expands through the turbine. It does work spinning the turbine, and that work comes out of the air as heat, so it leaves well below zero. The turbine is on the same shaft as the compressor, so the turbine drives the compressor: the machine pulls itself up by its own bootstraps, hence the name. Finally the cold, misty air passes the water separator and goes on to the mix manifold.
Part 2 · The key idea
Why compress the air before the turbine? Cooling in the turbine depends on its pressure drop The compressor raises the pressure so the turbine has a bigger drop: more cooling So low tapping pressures can be used (high-bypass engines, small turboprops) The compression heat is removed in the secondary heat exchanger first Here: drop of about 36 °C without the compressor, 54 °C with it More pressure drop, more cooling 0 40 80 120 160 1 2 3 4 Turbine pressure ratio Temperature drop (°C) no compressor: ratio 1.7, 36 °C drop with compressor: ratio 2.4, 54 °C drop Turbine inlet about 50 °C, efficiency 75 %
Chapter 12 · Air Conditioning
8
e-books by eatpl.in · © 2026 · Do not copy or distribute
Here is the question examiners love: why would a cooling machine compress the air, which heats it up? The answer is that the cooling in the turbine depends on the pressure ratio across it. The more pressure the air has to give up, the more work it does and the colder it leaves. Low pressure bleed air, on its own, would only give a small pressure drop and a small temperature drop. So the compressor raises the pressure first, giving the turbine a much bigger ratio to work with. The heat added by compression is not a problem, because it is removed straight away in the secondary heat exchanger. In this example, without the compressor the turbine would cool the air by about thirty six degrees; with it, by about fifty four. That is why bootstrap systems can use quite low tapping pressures, which suits high-bypass engines and small turboprops, where high-pressure bleed is not available or is undesirable.
Part 2 · Worked example
Temperature and pressure through a bootstrap pack -40 0 40 80 120 160 200 0 1 2 3 °C bar abs 200 °C 64 °C 108 °C 46 °C -8 °C 2.0 bar 1.9 bar 2.7 bar 2.6 bar 1.1 bar Bleed in After primary HX After compressor After secondary HX After turbine Assumptions Hot day: ram air 30 °C Bleed 200 °C, 2.0 bar abs Heat exchangers 80 % Compressor ratio 1.4 Turbine efficiency 75 % Below 0 °C at the turbine: the anti-ice valve adds hot air so the water separator stays just above freezing
Chapter 12 · Air Conditioning
9
e-books by eatpl.in · © 2026 · Do not copy or distribute
Let us put numbers on the bootstrap pack, using a hot day with ram air at thirty degrees. Bleed air enters at two hundred degrees and two bar absolute. The primary heat exchanger takes it down to about sixty four degrees with a small pressure loss. The compressor raises the pressure to about two point seven bar, and the temperature to about one hundred and eight. The secondary heat exchanger removes that heat, giving about forty six degrees. Then the turbine expands the air to just above cabin pressure, and the temperature falls to about minus eight. Notice the two curves: the temperature goes down, up, down and then plunges, while the pressure only rises once, in the compressor, and falls in the turbine. Turbine outlet air below zero would freeze the water separator, so an anti-ice valve adds a little hot air to keep it just above freezing.
Part 2 · Brake turbine
The brake turbine unit Higher tapping pressure; charge air goes through a heat exchanger straight to the turbine The turbine drives a compressor that draws in ambient air and blows it out through a restriction The back pressure brakes the turbine: energy removed from the charge air Optional jet pump : compressor output boosts cooling flow through the heat exchanger Lighter (one heat exchanger), better mass flow for its weight; no ground cooling without a jet pumpBrake turbine cold air unit HP bleed Heat exchanger T turbine cold air out shaft C compressor ambient air restriction = the "brake" • Higher tapping pressure; charge air through a heat exchanger straight to the turbine • Turbine drives a compressor that pumps ambient air through a restriction • The back pressure loads (brakes) the turbine: energy taken out = cooling • Lighter (one heat exchanger); no ground cooling unless a jet pump is fitted
Chapter 12 · Air Conditioning
10
e-books by eatpl.in · © 2026 · Do not copy or distribute
The brake turbine is an older design. Here the initial tapping pressure is higher, and the charge air goes through a heat exchanger directly to the turbine, without a compressor in its path. The turbine still has to do work, otherwise the air would not cool, so it drives a compressor that draws in ambient air and blows it out through a restriction. The back pressure on that compressor acts as a brake on the turbine, hence the name, and the energy the turbine must spend comes out of the charge air as heat. Some installations feed the compressor output into the cooling duct downstream of the heat exchanger, where it acts as a jet pump, pulling more cooling air through and improving the exchanger's efficiency. The brake turbine is lighter, with only one heat exchanger, and has a better mass flow for its weight, but unless a jet pump is fitted it cannot cool the air on the ground.
Part 2 · Turbo-fan
The turbo-fan unit A refinement of the brake turbine: the turbine drives a fan instead of a compressor The fan pulls the cooling air through the primary heat exchanger Not dependent on ram air : it can cool on the ground Extremely light and compact Needs a higher delivery pressure and turbine speed for the pressure drop Turbo-fan cold air unit bleed air Primary heat exch. ram / outside cooling air fan shaft cooling air overboard T turbine cold air • The turbine drives a FAN, not a compressor • The fan pulls cooling air through the heat exchanger: no need for ram air, so it works on the ground • Very light and compact; higher delivery pressure and turbine speed needed for the pressure drop
Chapter 12 · Air Conditioning
11
e-books by eatpl.in · © 2026 · Do not copy or distribute
The turbo-fan unit is a refinement of the brake turbine. Instead of driving a compressor, the turbine is coupled to a fan big enough to draw the required volume of cooling air through the primary heat exchanger. Watch the scene: bleed air passes through the heat exchanger and on to the turbine, which spins, sends cold air on to the cabin, and drives the fan on the same shaft. The fan pulls cooling air through the heat exchanger and blows it overboard. Because the fan makes its own cooling flow, the unit does not depend on ram air, so it can be operated on the ground. The design is extremely light and compact. The price is that the delivery pressure, and therefore the temperature, has to be higher, and the turbine must spin faster to achieve the necessary pressure drop. Remember: in a turbo-cooler, the cooling air through the heat exchanger is ram air or outside air, never bleed air.
Part 3 · Heat exchangers
Heat exchangers: surface heat exchange Charge air passes through ducts or tubes ; cooling air flows around them: they never mix The cooling medium is normally ram air Thermal efficiency at least 80 % of the charge-to-ambient difference Can never cool below ambient: hence the cold air unit In a vapour cycle, the evaporator and condenser are heat exchangers too Surface heat exchange hot charge air (tubes) ram air flows round the tubes: the two never mix Effectiveness 80 %: out = in − 0.8 × (in − ambient) Cruise, outside −30 °C 200 → 16 °C Ground, hot day 40 °C 200 → 72 °C It can approach the cooling air temperature but never go below it.
Chapter 12 · Air Conditioning
12
e-books by eatpl.in · © 2026 · Do not copy or distribute
A heat exchanger works on the principle of surface heat exchange. The hot charge air flows through a matrix of ducts or tubes, and the cooling air, normally ram air, flows around them. The two airflows never mix: heat simply passes through the metal walls from the hotter to the cooler air. A good exchanger achieves a thermal efficiency of at least eighty per cent, meaning it removes eighty per cent of the difference between the charge air temperature and the ambient temperature. Let us check with the numbers. Charge air at two hundred degrees, with ambient at minus thirty in the cruise, leaves at about sixteen degrees. With ambient at forty on a hot ground day it leaves at about seventy two. And it can never go below ambient, which is exactly why we need a cold air unit. In a vapour cycle system, which we will see later, the evaporator and condenser are heat exchangers too, but with a refrigerant on one side.
Part 3 · Ram air
Ram air doors and the ground cooling fan Ram air inlet and exit doors set the cooling flow through the heat exchangersOpened and closed by the pack controller as part of temperature control Closed (or nearly) for take-off and landing to stop debris being ingested A ground cooling fan draws air across the heat exchangers when there is no ram air The fan is electric or a third wheel on the cold air unit shaft Ram air circuit and ground fan belly skin inlet door (modulates) Primary HX Secondary HX fan ground cooling exit door • Doors modulated by the pack controller for temperature control • Closed (or nearly) for take-off and landing: no debris ingested • On the ground the fan (electric or a third wheel) pulls air through
Chapter 12 · Air Conditioning
13
e-books by eatpl.in · © 2026 · Do not copy or distribute
The heat exchangers need cooling air, and in flight that is ram air, scooped in through an inlet in the belly and dumped through an exit. Ram air inlet and exit doors control how much air flows through the ram air duct. They are opened and closed by the pack controller automatically, as part of the temperature control, opening wider when more cooling is needed. During take-off and landing they are closed, or nearly closed, to stop the system ingesting stones, dust and other debris thrown up from the runway. On the ground, and at low speed in the air, there is little or no ram air, so a ground cooling fan draws, or pushes, air across the primary and if necessary the secondary heat exchangers. The fan may be electrically driven, or it may be a third wheel on the shaft of the cold air unit, which is why you hear of three-wheel air cycle machines.
Part 3 · Water separator
The water separator Located downstream of the turbine of the cold air unit Cooling makes water condense as fog: worst at low altitude and on humid ground days A coalescer bag joins tiny drops; swirl vanes fling them out; water drains (often sprayed into the ram air) A relief (bypass) valve keeps air flowing if the separator ices up A temperature sensor and anti-ice valve add hot air to stop icing Water separator (coalescer type) coalescer bag tiny drops join into big ones swirl vanes drain: water sprayed into the ram air from turbine: cold, misty dry air out relief (bypass) valve opens if the bag ices or clogs anti-ice hot air • Position: downstream of the cold air unit turbine • Busiest at low altitude and on humid days on the ground • Temperature sensor + anti-ice valve keep it above freezing
Chapter 12 · Air Conditioning
14
e-books by eatpl.in · © 2026 · Do not copy or distribute
Look again at the turbine outlet: very cold air from a humid day cannot hold its moisture, so water condenses as a fine mist. If it reached the cabin it would drip from the ducts, soak the insulation, corrode structure and short electrical equipment. So a water separator is fitted downstream of the turbine. Misty air first passes through a coalescer bag, a fabric sock in which the tiny droplets merge into larger ones. Swirl vanes then spin the air, flinging the drops outwards to the wall, where they are collected and drained, often sprayed into the ram air to help cool the heat exchanger. Dry air goes on to the mix manifold. The problem is worst at low altitude and on humid days on the ground. Because the air can be below zero, the separator could ice up, so a temperature sensor controls an anti-ice valve that adds hot air, and a relief valve lets air bypass the bag if it does block.
Part 3 · Humidifier
The humidifier High-altitude outside air holds almost no water: 1 to 2 % relative humidity Long flights in such dry air cause discomfort : dry eyes, nose and throat A humidifier adds moisture to the conditioned air at high altitude Typical venturi type: potable (drinking) water atomised by conditioned air Contrast: the water separator removes water, mainly at low altitude Venturi humidifier conditioned air potable water atomised by the airflow 1-2 % outside air RH ≈ 30 % comfortable RH Long flights at high altitude: very dry air, so moisture may be added
Chapter 12 · Air Conditioning
15
e-books by eatpl.in · © 2026 · Do not copy or distribute
At the other extreme, aircraft that fly at high altitude for long periods have the opposite problem. The outside air at forty thousand feet holds almost no water, with a relative humidity of only one or two per cent, and the cabin air made from it is extremely dry. Over many hours that causes real discomfort: dry eyes, nose and throat. So some aircraft fit a humidifier, which raises the moisture content of the conditioned air to a more comfortable level. A typical design is the venturi humidifier. Conditioned air flows through a venturi, and the low pressure at the throat draws in water from the aircraft's drinking water supply, which is atomised into a fine spray by the air itself. Keep the two devices apart in your mind: the water separator removes water, and is busiest low down and on humid days; the humidifier adds water, and is used at high altitude.
Part 4 · Mass flow
The mass flow controller Keeps an approximately constant mass flow to the cabin Regardless of engine rpm , altitude and which bleed source is in use Bleed systems: a variable orifice (venturi) valve adjusts itself to upstream and downstream pressures Blower systems: the controller spills excess air to atmosphere Constant inflow lets the outflow valve alone set cabin pressure Mass flow control bleed: pressure varies venturi throat modulating valve flow sensing (Δp at throat) • Delivers an approximately constant MASS flow, whatever the engine rpm, altitude or bleed source • Bleed systems: a variable orifice valve adjusts itself to the upstream and downstream pressures • Blower systems: excess air is spilled overboard
Chapter 12 · Air Conditioning
16
e-books by eatpl.in · © 2026 · Do not copy or distribute
The mass flow controller makes sure a constant mass of air reaches the cabin, whatever the engine rpm, the altitude, or whether the air comes from the low or high pressure stage or the A P U. In a bleed air system it is usually a variable orifice valve with a venturi. The pressure drop at the venturi throat measures the mass flow, and the valve automatically adjusts its opening so that the required mass flow passes, irrespective of changes in pressure upstream and downstream. On many airliners this is the pack flow control valve itself. In a blower system the controller does the job differently: it spills the excess air overboard. Why does it matter so much? Because pressurisation, as we will see in the next lesson, works on the principle of a constant inflow and a variable outflow. If the inflow is constant, the outflow valve alone can set the cabin pressure.
Part 4 · Temperature control
Temperature control: mixing hot air with cold bleed from pack valve PACK cold air unit Temperature control (hot air bypass) valve MIX duct sensor CABIN cabin sensor Temperature controller compares selected with sensed Selector: AUTO °C or MANUAL HOT / COLD
Chapter 12 · Air Conditioning
17
e-books by eatpl.in · © 2026 · Do not copy or distribute
The temperature of the air entering the cabin is controlled by mixing hot air with cooled air. Some bleed air bypasses the pack through the hot air bypass valve, also called the temperature control valve, and joins the cold pack output at the mixing point. In automatic control, the pilot selects a temperature. Sensors in the supply duct and in the cabin are compared electronically with the selected value, and any difference moves the temperature control valve, letting more or less air bypass the cooling components, until the mixed air is right. The same controller also drives the ram air doors. In manual control, the crew move the valve directly with a hot and cold, or increase and decrease, switch, watching the duct temperature. Older or simpler aircraft use a purely manual system, with valves positioned by hand. So cabin temperature can be controlled either manually by the pilot or automatically.
Part 5 · Distribution
Getting the air to the cabin Packs feed a mix manifold , then risers in the sidewalls to ceiling outlets Air circulates across the cabin and leaves at floor level Warm air in wall and floor passages keeps surfaces at cabin temperature: fewer draughts Separate cold and heated ducting Flight deck: adjustable crew outlets and window demisting Cabin air distribution (cross-section) underfloor: mix manifold, recirculation fans, cargo sidewall riser ceiling outlets air circulates across and leaves at floor level Warm air in wall and floor passages keeps the cabin surfaces at cabin temperature: fewer draughts
Chapter 12 · Air Conditioning
18
e-books by eatpl.in · © 2026 · Do not copy or distribute
Once the air is conditioned, it has to be spread evenly through a long cabin without draughts. The packs feed a mix manifold under the floor. From there, risers run up inside the sidewalls to outlets along the ceiling, as the scene shows. The air circulates across the cabin and leaves through grilles at floor level. Most transports also send warm air through passages in the floor and walls, which keeps the inner surfaces at cabin temperature. That reduces draughts and the cold radiation you feel from a cold window, and it allows the entering air to be closer to the cabin temperature. The ducting is in two separate sections, for cold and for heated air. The flight deck has its own supply, with crew outlets that can be adjusted for direction and quantity, and air to the windows for demisting. Finally the used air leaves the aircraft through the outflow valve, which is the subject of the next lesson.
Part 5 · Gasper air
Gasper air Cold conditioned air to individual outlets above each seat: punkah louvres Tapped from a zone supply duct upstream of where trim air is added A gasper fan gives a positive supply to all zones Each outlet is individually controlled by the passenger The flight deck has similar adjustable outlets Gasper air zone supply duct (from the packs) fan gasper fan punkah louvres: each passenger aims and opens their own trim air added DOWNSTREAM tapped UPSTREAM of the trim air Result: cool, positive airflow to every seat whatever the zone temperature
Chapter 12 · Air Conditioning
19
e-books by eatpl.in · © 2026 · Do not copy or distribute
Gasper air is the cool air that comes from the little adjustable nozzle above your seat, the punkah louvre. It is cold conditioned air, tapped from one of the zone supply ducts upstream of the point where trim air is added. That detail matters: it means the gasper air stays cool whatever temperature the zone itself has been trimmed to, so every passenger can get a cool stream of air even in a warm zone. A gasper fan provides a positive supply of this air to all zones, so the flow does not depend on duct pressure, and each outlet is individually controlled: the passenger can aim it and open or close it. On the flight deck the crew have similar adjustable outlets.
Part 5 · Zone trim
Zone trim: one pack temperature, several zone temperatures Packs 12 °C set by the zone wanting the coolest air mix manifold hot trim air (150 °C) from a pressure-regulating valve Flight deck wants 22 °C 7 % trim air Forward cabin wants 24 °C 9 % trim air Aft cabin wants 20 °C 6 % trim air Each zone's trim valve adds just enough hot air: fraction = (zone − pack) ÷ (trim − pack)
Chapter 12 · Air Conditioning
20
e-books by eatpl.in · © 2026 · Do not copy or distribute
A long cabin cannot be kept at one even temperature by a single supply: the flight deck, a full forward cabin and a half-empty aft cabin all need different amounts of cooling. So the cabin is divided into zones, each treated as a separate distribution problem. The packs deliver air at the temperature required by the zone that needs the coolest air, here twelve degrees. Each other zone then gets its own small addition of hot trim air to bring it up to the temperature it wants. The trim air comes from a pressure-regulating valve, and its quantity for each zone is set by the temperature control system. Let us work the numbers. With trim air at a hundred and fifty degrees, the forward cabin wanting twenty four degrees needs about nine per cent trim air in its supply; the aft cabin at twenty degrees about six per cent. Gasper air, remember, is tapped before the trim air is added.
Part 5 · Recirculation
Recirculation fans Fans draw cabin air from underfloor , through filters , back into the distribution Packs can run at a reduced rate in the cruise: less bleed , less fuel The cabin ventilation rate stays constant Air from toilets and galleys is not recirculated: it goes overboard via the outflow valves Typically about half the cabin supply is recirculated (type-dependent) Recirculation CABIN Packs fresh air Mix manifold Recirc fans + filters cabin air from underfloor galley and toilet air: overboard via outflow • Packs can run at a reduced rate in the cruise: less bleed, less fuel • Ventilation rate through the cabin stays constant • Underfloor cabin air is filtered, then returned to the mix manifold • Galley and toilet air is never recirculated • Typical split: roughly half fresh, half recirculated (type-dependent)
Chapter 12 · Air Conditioning
21
e-books by eatpl.in · © 2026 · Do not copy or distribute
Recirculation fans let the aircraft reuse some of its cabin air. The fans draw air from the underfloor area, pass it through filters, and put it back into the conditioned air distribution system, where it is mixed with fresh air from the packs. The benefit is fuel: the packs can be run at a reduced rate during the cruise, which reduces the bleed taken from the engines, while the ventilation rate through the cabin stays constant, so passengers do not notice any difference in airflow. On many airliners about half the air you breathe has been recirculated, though the share varies by type. Air from the regions of the toilets and galleys, with its smells and moisture, is never recirculated. It is extracted and vented directly overboard by the pressurisation discharge valves, the outflow valves.
Part 6 · Vapour cycle
The vapour cycle (refrigeration) system EVAPORATOR liquid boils: absorbs heat from cabin air CONDENSER vapour condenses: gives heat to ram air COMP compressor (electric or air driven) receiver-dryer expansion valve cabin air in cooled air ram air heat out high-pressure vapour (hot) high-pressure liquid low-pressure liquid (cold) low-pressure vapour
Chapter 12 · Air Conditioning
22
e-books by eatpl.in · © 2026 · Do not copy or distribute
The vapour cycle system works just like a domestic refrigerator, or the galley cart cooling on some large aircraft, and in aircraft its use is now mostly limited to small piston types. A refrigerant, a liquid that boils at a low temperature, about three point five degrees at sea level pressure, circulates in a closed loop. Start at the evaporator. Low pressure liquid boils there, changing to vapour and absorbing heat from the cabin air blown through it, so the cabin air is cooled. The compressor, driven electrically or by air, raises the pressure of the vapour, and with it the boiling point. In the condenser, cold ram air passes over the hot high-pressure vapour, which condenses back to liquid, giving up its latent heat. The liquid is stored in the receiver-dryer, then passes the expansion valve, which drops its pressure and boiling point before it enters the evaporator again. The principle: liquid into vapour absorbs heat.
Part 6 · Vapour cycle in detail
The refrigerant around the loop Component Refrigerant enters as Leaves as What happens Evaporator Low-pressure liquid (cold) Low-pressure vapour Boils, absorbing heat from the cabin air Compressor Low-pressure vapour High-pressure vapour (hot) Pressure and boiling point raised Condenser High-pressure vapour High-pressure liquid Condenses; latent heat given to ram air Receiver-dryer High-pressure liquid High-pressure liquid Reservoir; moisture removed Expansion valve High-pressure liquid Low-pressure liquid Pressure and boiling point dropped
Order: compressed, cooled (condensed), expanded, heated (evaporated). The air cycle uses air itself; the vapour cycle uses a refrigerant that changes phase.
Chapter 12 · Air Conditioning
23
e-books by eatpl.in · © 2026 · Do not copy or distribute
Let us lock in the vapour cycle with a table, because the order of components and the state of the refrigerant are classic exam material. The evaporator receives cold, low-pressure liquid, which boils into low-pressure vapour as it absorbs heat from the cabin air. The compressor takes that low-pressure vapour and delivers hot, high-pressure vapour, raising its boiling point. The condenser turns it into high-pressure liquid, giving its latent heat to the ram air. The receiver-dryer is a reservoir, and removes moisture from the refrigerant. And the expansion valve drops the pressure, and so the boiling point, so the liquid leaves cold and at low pressure, ready to boil again. In short the refrigerant is compressed, cooled, expanded and heated, in that order. Do not confuse this with the air cycle, where the working fluid is the air itself and the cooling comes from a turbine.
Pack faults
When things go wrong in a pack Symptom or fault Cause What happens / what to do Pack overheat warning Compressor outlet or duct too hot, e.g. ram air blocked Pack valve closes automatically; the other pack carries the load Mist from the outlets Water separator not working, humid air Uncomfortable but not dangerous on its own Separator iced or blocked Turbine outlet below 0 °C Anti-ice valve adds hot air; relief valve bypasses the bag Oily smell or blue haze Failed oil seal in the engine compressor or cold air unit Contaminated air: isolate the source (bleed or pack OFF) One pack lost Any failure Duplication: one pack still gives at least 0.5 lb per seat per minute
Mist that appears suddenly with a loud bang and a pressure change is a decompression, not a pack fault: see lesson 13.
Chapter 12 · Air Conditioning
24
e-books by eatpl.in · © 2026 · Do not copy or distribute
Let us finish the pack itself with the faults you may meet. A pack overheat warning means the compressor outlet or the pack duct has got too hot, perhaps because the ram air is blocked; the pack valve closes automatically and the other pack takes over. Mist coming from the outlets usually means the water separator is not doing its job on a humid day: uncomfortable, but not dangerous in itself. If the turbine outlet falls below freezing the separator can ice, and the anti-ice valve and the relief valve deal with that. An oily smell or a blue haze points to a failed oil seal, either in the engine compressor or in the cold air unit itself, which is lubricated and turns very fast; the source must be isolated. And the loss of one pack is covered by the duplication requirement. Be careful with one trap: sudden fog in the cabin with a bang is a decompression.
Summary
Air conditioning: the essentials Requirements 1 lb/seat/min fresh air (0.5 after a failure), 18 to 24 °C, about 30 % RH, CO under 1 in 20 000, duplicated. Conditioned air: temperature, humidity, pressure.
Bootstrap Bleed → primary HX → compressor → secondary HX → turbine (drives the compressor) → water separator. Compressing first gives the turbine a bigger pressure drop.
Other cold air units Brake turbine: turbine loads a compressor of ambient air through a restriction; no ground cooling without a jet pump. Turbo-fan: turbine drives a fan; works on the ground.
Pack components HX ≥ 80 %, never below ambient. Ram doors closed for take-off and landing. Ground fan. Water separator after the turbine, with anti-ice and relief. Humidifier at high altitude.
Control and distribution Constant mass flow. Temperature by hot air bypass, auto or manual. Gasper air before trim air. Trim for each zone. Recirculation saves bleed; galley and toilet air dumped.
Vapour cycle Compressor → condenser → receiver → expansion valve → evaporator. Liquid boiling into vapour absorbs heat. Mainly small piston aircraft.
Chapter 12 · Air Conditioning
25
e-books by eatpl.in · © 2026 · Do not copy or distribute
Let us gather it all up. The cabin needs one pound of fresh air per seat per minute, at least half that after a failure, at eighteen to twenty four degrees and about thirty per cent humidity, with carbon monoxide below one part in twenty thousand, from a duplicated system. In a bootstrap pack the air goes from the primary heat exchanger to the compressor, the secondary heat exchanger and the turbine, which drives the compressor, and then to the water separator; compressing first gives the turbine a bigger pressure drop and more cooling. The brake turbine and turbo-fan are the alternatives. Heat exchangers reach about eighty per cent and never go below ambient; ram doors close for take-off and landing; the water separator sits after the turbine. The mass flow is constant and temperature is set by mixing. Gasper air is taken before the trim air. And in the vapour cycle, liquid boiling into vapour absorbs the heat.