Aircraft Systems · Chapter 19
Smoke and Fire Detection How an aircraft knows it is on fire: designated fire zones, spot and continuous detectors, double loops, the fire test, flight deck warnings and drills, and the smoke detectors that watch the places nobody can.
loop A loop B
A AND B
ENG 1 FIRE
DETECT
fast, reliable, testable, never automatic discharge
© 2026 eatpl.in. For the personal study of eatpl.in students only. Do not copy or distribute.
e-books by eatpl.in · © 2026 · Do not copy or distribute
Welcome to smoke and fire detection. A fire in flight is one of the few emergencies that can destroy an aircraft within minutes, so the first job is to find it fast and tell the crew clearly, without crying wolf. In this lesson we look at where detection is fitted, at the spot detectors and continuous fire wires used in engines and the A P U, at why two loops must agree before you get a warning, how the fire test works, what the warning looks and sounds like, and the drill that follows. Then we turn to smoke detectors in cargo holds, electrical bays and lavatories. Let us begin.
Roadmap
Smoke and fire detection: the plan 1 · Where and why The fire triangle, designated fire zones , and what a detection system must and must not do.
2 · Fire detectors Spot detectors (melting link, differential expansion) and continuous fire wires: resistive, capacitive, gas-filled.
3 · Loops, test, warning Double loops and AND logic, the fire test , the bell and red light, and the drill .
4 · Smoke detection Light scatter , ionisation , semiconductor and flame detectors; cargo holds, avionics bays and lavatories.
Chapter 19 · Smoke and Fire Detection
2
e-books by eatpl.in · © 2026 · Do not copy or distribute
Here is the plan. In part one we look at why fire is so dangerous in an aircraft and where the regulations insist on detection: the designated fire zones, such as the engine nacelles and the A P U bay. Part two covers the detectors themselves, first the older spot types, the melting link and the differential expansion switch, and then the continuous fire wires that run right round an engine: resistive, capacitive and gas-filled. In part three we see why there are two loops that must agree, how the crew test the system before flight, what the warning looks and sounds like, and the drill that follows. Finally, part four turns to smoke detection, which protects the places nobody can watch: the cargo holds, the electrical equipment bays and the lavatories.
Part 1 · Why fire matters
The fire triangle on an aircraft A fire needs fuel , heat and oxygen ; the self-sustaining chain reaction makes it a tetrahedron Aircraft carry all three: fuel, hydraulic fluid and oil ; hot casings, bleed ducts and brakes ; air everywhere Remove any one and the fire dies: shut off fuel, cool, smother, or break the chain Aircraft are designed to be intrinsically safe , but the worst case must still be covered So detection must be rapid and reliable : a few minutes can decide the outcome
chain
reaction
FUEL HEAT OXYGEN
fuel, hydraulic fluid, oil leaks hot casings, bleed ducts, brakes, electrical faults air in every zone; oxygen systems
remove any one side and the fire goes out
Chapter 19 · Smoke and Fire Detection
3
e-books by eatpl.in · © 2026 · Do not copy or distribute
Every fire needs three things: fuel, heat and oxygen. Take any one away and the fire goes out. Modern teaching adds a fourth element, the chemical chain reaction that keeps the flames going, which turns the triangle into a tetrahedron; that matters later, because halon extinguishants work by breaking that chain. Now look at an aircraft. It carries tonnes of fuel, plus hydraulic fluid and oil under pressure in pipes that can leak. It has hot engine casings, hot bleed air ducts, hot brakes and electrical wiring. And there is air everywhere. The aircraft is designed to be intrinsically safe, with fuel and ignition sources kept apart, but the designers must still plan for the worst case: a pipe breaks and fuel sprays onto a hot casing. When that happens, minutes count, so detection must be fast and dependable.
Part 1 · Where detection is fitted
Designated fire zones and other protected areas Designated fire zone : an area where a fire risk may exist after failure or leakage of a componentEngines and the APU are fire zones, closed off by fireproof bulkheads (firewalls) They need fire detection and extinguishing ; main wheel wells and bleed ducts have overheat or fire detection Smoke detection for cargo holds, avionics bays and lavatoriesDetection must never discharge the engine extinguishers automatically: the crew decide
Engine nacelles
APU bay
Wheel well
Cargo holds
Avionics bay
Lavatory
Designated fire zone: fire detection + extinguishing
Overheat / fire detection (wheel wells, bleed ducts)
Cargo: smoke detection (gives a FIRE warning)
Smoke detection: avionics bay, lavatories
Chapter 19 · Smoke and Fire Detection
4
e-books by eatpl.in · © 2026 · Do not copy or distribute
Where must detection be fitted? The key term is the designated fire zone: an area where a fire risk may exist following the failure or leakage of a component or its equipment. The engine nacelles are the classic example, and so is the A P U bay in the tail. Each fire zone is closed off by fireproof bulkheads, the firewalls, so a fire cannot spread into the wing, the pylon or the fuselage, and each has both fire detection and a fixed extinguishing system. The main wheel wells, where hot brakes are stowed after take-off, and the hot bleed ducts are watched by overheat or fire detectors too. The cargo holds, the avionics bay and the lavatories get smoke detectors. One rule to remember: the detection system warns the crew but must never fire the engine extinguishers automatically.
Part 1 · Requirements
What a fire detection system must do Fast Rapid detection of a localised fire or overheat anywhere in the zone.
No false alarms A false warning can cause an unnecessary shutdown or diversion, and destroys trust in the system.
Clear warning Aural and visual on the flight deck, showing which engine or zone.
Testable A test from the flight deck before flight proves the circuits.
Self-resetting The warning should go out when the fire is out , to show the extinguisher worked.
Never automatic discharge Engine bottles are fired by the crew . (Exceptions: the APU on many types, and lavatory bins.)
Chapter 19 · Smoke and Fire Detection
5
e-books by eatpl.in · © 2026 · Do not copy or distribute
What do we want from a fire detection system? First, speed: it must detect a localised fire or overheat quickly, wherever it starts in the zone. Second, it must not give false alarms. A false fire warning on take-off can lead to a rejected take-off or an engine shutdown that was not needed, and a system that cries wolf is soon not believed. Third, the warning must be clear, both aural and visual, and it must say which engine or zone is on fire. Fourth, the crew must be able to test it from the flight deck. Fifth, the warning should reset by itself when the temperature falls, because that is how you know the fire has gone out. And finally, the engine system must not discharge the extinguishers on its own. The crew decide. The exceptions are the A P U, which on many aircraft shuts down and fires its own bottle, and the lavatory waste-bin extinguisher.
Part 2 · Fire detectors
Spot and continuous detectors at a glance Detector Senses How it works Resets? Melting link Heat at one spot Fusible plug melts, contacts close No : permanent warningDifferential expansion Heat at one spot Tube expands more than the bow, contacts close; short delay Yes Thermocouple (older types) Rapid rise of temperature Hot and cold junctions; the voltage difference trips a relay Yes Resistive fire wire Heat anywhere along it Negative coefficient of resistance : core resistance fallsYes Capacitive fire wire Heat anywhere along it Positive coefficient of capacitance : feedback current risesYes Gas-filled (pneumatic) Average and local heat Gas released from the core raises the pressure; pressure switch Yes
Spot detectors watch one point; continuous detectors (fire wires) watch their whole length, so they are used round engines and APUs.
Chapter 19 · Smoke and Fire Detection
6
e-books by eatpl.in · © 2026 · Do not copy or distribute
Fire detectors come in two families. Spot detectors watch a single point. The melting link is the oldest and simplest, and it has one big drawback: once it has operated it stays operated. The differential expansion switch also watches one spot, but it resets. Some older aircraft used thermocouple systems that respond to a rapid rate of temperature rise. Continuous detectors, usually called fire wires, watch their whole length, so a single run can be routed right round an engine and catch a fire wherever it starts. There are three kinds. In the resistive type, heat lowers the resistance of the core. In the capacitive type, heat raises its capacitance. In the gas-filled type, heat releases gas and raises the pressure in a sealed tube. We will look at each in turn, and especially at what a fault does to each, because that is a favourite exam question.
Part 2 · Spot detectors
Melting link detectors Found on older aircraft A pair of contacts held apart by a fusible plug At a set temperature the plug melts , the contacts close and the fire warning circuit is made Major drawback: the contacts do not open again after the fire is out Result: a permanent fire warning , so the crew cannot tell whether the extinguisher worked
Normal
Fire
fusible plug
circuit open
plug holds contacts apart
plug melted
circuit made: FIRE
stays closed when cool:
permanent warning
Chapter 19 · Smoke and Fire Detection
7
e-books by eatpl.in · © 2026 · Do not copy or distribute
The melting link detector is about as simple as a fire detector can be, and it is found on older aircraft. Two spring contacts want to snap together, but a fusible plug holds them apart. The plug is made of an alloy that melts at a chosen temperature. When the zone gets that hot, the plug melts, the contacts close, and the fire warning circuit is complete, so the bell rings and the red light comes on. The problem is what happens next. When the fire has been put out and the zone cools down, the plug has gone, so the contacts stay closed. The crew are left with a permanent fire warning. They cannot tell whether the extinguisher has worked, and that is exactly the information they need. That is why later detectors are designed to reset as soon as the temperature falls.
Part 2 · Spot detectors
Differential expansion detectors Two dissimilar metals : an expansion tube and a spring bow carrying the contacts Heat: the tube grows faster than the bow, the bow is drawn straight and the contacts close Cooling: the tube shortens, the contacts open and the warning cancels Has a short time delay (about two seconds) so vibration cannot cause a false warning Often fitted at engine cooling air outlets : internal engine overheat warning
Differential expansion (spot) detector
Cool
gap: contacts open
Hot
tube grows
bow pulled straight: contacts close
Expansion tube : high expansion metal
Spring bow : low expansion, carries the contacts
Cools : tube shortens, contacts open, warning cancels
Short time delay : vibration cannot trigger a false warning
Chapter 19 · Smoke and Fire Detection
8
e-books by eatpl.in · © 2026 · Do not copy or distribute
The differential expansion detector uses two metals that expand at different rates. A spring bow, made of a low expansion metal, carries a pair of contacts and is fixed at both ends inside an expansion tube made of a high expansion metal. When the tube is heated it grows longer faster than the bow, so it pulls the ends of the bow apart, the bow straightens and the contacts are drawn together. That completes the fire warning circuit. When the temperature falls, the tube shortens again, the bow springs back, the contacts open and the warning goes out, so unlike the melting link it resets. Because the contacts are close together, a hard jolt could make them touch briefly, so the unit has a short time delay, typically about two seconds, before the warning comes on. That delay is there to stop vibration giving false warnings. These units are often mounted at engine cooling air outlets to give an internal engine overheat warning.
Part 2 · Continuous detectors
The fire wire: a continuous sensing element A stainless steel (or Inconel) tube, earthed to the structure A central electrode wire running down the middle Between them a temperature-sensitive insulating core: ceramic or eutectic salt Cold, the core insulates ; hot, it lets current leak from electrode to tube Senses heat anywhere along its length ; works as resistive or capacitive (one design uses both)
Outer tube stainless steel / Inconel, earthed
Temperature-sensitive core ceramic or eutectic salt
Centre electrode
heat: current leaks core → tube
Chapter 19 · Smoke and Fire Detection
9
e-books by eatpl.in · © 2026 · Do not copy or distribute
Continuous detectors are usually called fire wires, and they all start from the same construction. On the outside is a thin stainless steel or Inconel tube, which is earthed to the aircraft structure. Down the middle runs a central electrode wire. The space between them is packed with a temperature-sensitive core, a ceramic or a eutectic salt. When it is cold, the core is a good insulator, so almost no current passes from the electrode to the tube. As it gets hot, the core changes its electrical properties, and current begins to leak from the electrode, through the core, to the earthed tube. Because the element is long and thin, it can be laid right round an engine, and it will sense heat anywhere along its length. Depending on the core material and the control unit, the element works on resistance or on capacitance; one system uses both.
Part 2 · Resistive fire wire
Negative coefficient of resistance: hotter means lower resistance
100 Ω 1 kΩ 10 kΩ 100 kΩ 1 MΩ 10 MΩ 0 100 200 300 400 500
element temperature (°C)
alarm level (about 1 kΩ here)
core resistance
FIRE warning
Negative temperature
coefficient of resistance
temperature ↑
resistance ↓
leakage current ↑
at the set level: warning
cools below it:
resets by itself
short circuit = zero ohms
= false FIRE warning
Chapter 19 · Smoke and Fire Detection
10
e-books by eatpl.in · © 2026 · Do not copy or distribute
The resistive fire wire works on a negative coefficient of resistance. As the temperature of the core rises, its resistance falls, and the leakage current between the centre electrode and the outer tube increases. The graph shows a typical core, with resistance on a logarithmic scale. Cold, it is around a megohm. As it heats, the resistance tumbles, and at the alarm level set by the control unit, here about three hundred degrees, enough current flows to operate the warning. When the zone cools below that temperature, the resistance rises again and the system resets by itself. So for the exam: temperature up, resistance down, current up. Now the weakness. A short circuit between the electrode and the tube looks exactly like a very hot core, because the resistance drops to almost zero. So a short circuit in a resistive fire wire gives a false fire warning.
Part 2 · Capacitive fire wire
Positive coefficient of capacitance Heat increases the capacitance of the element The control unit feeds it half-wave rectified AC : it charges on one half cycle It stores the charge and returns it as a feedback current on the other half Feedback reaches the set level: aural and visual fire warning ; it resets when cool Advantage: a short to earth stores no charge, so it does not give a false fire warning
CONTROL UNIT
sensing element (a long capacitor)
charge
feedback
Half-wave rectified AC in, stored charge back
alarm level for the feedback current
cool hot: FIRE
Short to earth : no stored charge, no feedback → no false fire warning
Chapter 19 · Smoke and Fire Detection
11
e-books by eatpl.in · © 2026 · Do not copy or distribute
The capacitive fire wire uses the same kind of element, but the control unit treats it as a long capacitor. As the temperature rises, the capacitance increases, which is a positive coefficient of capacitance. The control unit polarises the element with half wave rectified A C. On one half cycle, the element charges up. On the next half cycle, when no voltage is applied, it discharges, and that stored charge comes back to the control unit as a feedback current. The hotter the element, the more charge it stores and the bigger the feedback current, until at a preset level the aural and visual fire warnings operate. When it cools, the feedback falls and the system resets. The big advantage over the resistive type is what happens with a short to earth. A shorted element cannot store any charge, so there is no feedback current and no false fire warning, just a fault indication.
Part 2 · Gas-filled detector
Gas-filled (pneumatic) detectors A sealed stainless steel tube with a gas-absorbing core , charged with gas under pressure Heat releases gas from the core: the pressure rises rapidly A pressure switch at the end signals the control box: fire warning Also senses a general overheat , e.g. a hot bleed-air leak in the zone Tube broken: pressure falls , the same switch unit shows a LOOP FAULT
RESPONDER
pressure switches
heat releases gas
sealed tube, gas-absorbing core
Pressure rises → alarm switch closes → FIRE / overheat
Pressure lost (tube broken) → integrity switch → LOOP FAULT
Chapter 19 · Smoke and Fire Detection
12
e-books by eatpl.in · © 2026 · Do not copy or distribute
The gas-filled, or pneumatic, detector uses pressure instead of electrical resistance. It is a sealed stainless steel tube containing a core that absorbs gas. During manufacture the gas is forced in under pressure and partly soaked up by the core, and then the tube is sealed. When any part of the tube is heated, the core releases its gas and the pressure inside rises rapidly. A pressure switch in the responder at the end of the tube senses the rise and, through the control box, gives the fire warning. Because the gas pressure also rises with the average temperature of the whole tube, the system can detect a general overheat, such as a hot bleed air leak. And if the tube is broken, the gas escapes and the pressure falls. The responder senses that drop and shows a loop fault, not a fire.
Part 3 · Double loops
Two loops, and both must agree Fire wires run round each fire zone as a continuous double loop : loop A and loop B AND logic : both loops must detect before the fire warning comes onOne damaged loop therefore cannot give a false fire warning A failed loop gives a FAULT ; the system can carry on with the single good loop Loops can survive a single wire break and keep working
ENGINE
loop A
loop B
CONTROL UNIT
FIRE only if A AND B
Chapter 19 · Smoke and Fire Detection
13
e-books by eatpl.in · © 2026 · Do not copy or distribute
Fire wires are not fitted as a single run. Around each engine there are two complete loops, called loop A and loop B, running side by side. The control unit uses AND logic: both loops must detect the fire before the warning comes on. Why? Because a single loop can be damaged, chafed or shorted, and with the resistive type a short looks just like a fire. By insisting that both loops agree, one damaged loop cannot produce a false fire warning. If one loop does fail, the control unit shows a fault on the fire detection panel or on the electronic display, and the system can then work on the remaining good loop alone, either automatically or when the crew select it. The loops are also designed to keep working with a single break in the wire. So you get both protection against false warnings and a good chance of keeping detection after a fault.
Part 3 · Double loops
What the crew see for each loop state Loop A Loop B Result on the flight deck Fire Fire FIRE warning : bell and steady red lightFire Normal No fire warning (one loop cannot do it on its own) Fault (failed) Normal FAULT light; system switches to single-loop operation on loop BFault (failed) Fire In single-loop mode: FIRE warning from loop B alone Fault Fault Detection lost for that zone: DET FAULT ; follow the checklist Gas tube broken — Pressure loss sensed: LOOP FAULT , never a fire warning
Any fault that could give a false fire warning must still be treated as a real fire until proved otherwise.
Chapter 19 · Smoke and Fire Detection
14
e-books by eatpl.in · © 2026 · Do not copy or distribute
This table shows how the double loop behaves. With both loops healthy, a fire warning needs both to sense heat. If only one loop sees a fire, nothing appears, because one loop cannot raise the alarm on its own. If one loop fails, the crew get a fault light, and the system switches to single loop operation on the good loop; from then on, that one loop alone can give the fire warning. If both loops fail, detection is lost for that zone, and the checklist decides what happens next. In a gas filled system, a broken tube loses pressure and shows a loop fault, never a fire. Depending on the aircraft type, a limited number of flights may be allowed on a single loop. One golden rule: any fault in a fire detection system that could give a false fire warning must be treated as a real fire.
Part 3 · Fire test
The fire test before flight A fire test switch on the flight deck must be available before flight On test, every engine shows the same indications as a real fire : red lights and bell This proves circuit continuity from the loops to the warnings A break in an engine's circuit: no test indication for that engine; a gas leak also prevents it A single failed loop may show a FAULT ; limited operation on one loop may be allowed
FIRE PANEL · TEST pressed
ENG 1 FIRE
APU FIRE
ENG 2 FIRE
no test light: circuit broken
FAULT
one loop failed: system runs
on the other loop
TEST
same lights and bell as a real fire,
on every engine: proves continuity
Chapter 19 · Smoke and Fire Detection
15
e-books by eatpl.in · © 2026 · Do not copy or distribute
Before flight, the crew must be able to prove the detection system works, so a fire test switch is fitted on the flight deck. When the test is selected, the system produces indications identical to a real fire on every engine, and usually on the A P U too: the red lights in the fire handles, the master warning and the bell. That proves the circuit is continuous all the way from the sensing loops to the warnings. Now look at the panel. Here the A P U handle has stayed dark. That tells the crew there is a break in that circuit, because a broken fire warning circuit gives no test indication. In a gas filled system, a leak from the tube will also stop the test warning appearing. The system may also show a fault light when one loop has failed and it is running on the other. Depending on the type, limited operation on a single loop may be permitted.
Part 3 · Warnings
What a fire warning looks and sounds like Must be attention-getting , but not startling Aural: a bell , klaxon or continuous repetitive chime A master warning light and caption, e.g. ENG 1 FIRE A steady red light in the affected engine's fire handle (not flashing) Overheat : an amber light only (caution, no fire bell)
MASTER WARNING
fire bell / klaxon / chime
ENG 1 FIRE
1 FIRE HANDLE
steady red, not flashing
ENG 1 OVHT
overheat: light only, no fire bell
Chapter 19 · Smoke and Fire Detection
16
e-books by eatpl.in · © 2026 · Do not copy or distribute
What does a fire warning look and sound like? The design aim is attention getting, but not startling: the crew must notice it at once, but it must not make them panic. Typically, a bell sounds, or on some aircraft a klaxon or a continuous repetitive chime. A red master warning light comes on in front of both pilots, with a caption such as engine one fire. And the fire handle for the affected engine lights up with a steady red light. It does not flash, and every engine has its own light, while the bell is common to them all. So in the exam, flight deck fire warnings are a light and a bell. An engine overheat is less urgent, so it gets an amber caution light, without the fire bell. The overheat may be the first sign of trouble, such as a bleed leak, and the crew handle it with a separate checklist.
Part 3 · The drill
The engine fire drill: shut down and isolate, then discharge
Shut down and isolate first, then discharge: always by the aircraft's own checklist
1 Silence cancel the bell 2 Thrust lever close (idle) 3 HP fuel / start lever cut off: engine shut down 4 Pull fire handle isolates fuel, bleed, hydraulics, generator; arms squibs 5 Discharge bottle 1 into the engine fire zone 6 Wait 30 s still lit? discharge bottle 2 7 Land as soon as possible
Order to remember: shut down the engine → pull the fire handle → fire the first bottle
Chapter 19 · Smoke and Fire Detection
17
e-books by eatpl.in · © 2026 · Do not copy or distribute
Once the warning comes, the drill is carried out in strict order, using the aircraft's own checklist. Here is a representative version. First, silence the bell, so the crew can think and talk. Second, close the thrust lever on the affected engine. Third, cut off the fuel with the H P cock or start lever, so the engine shuts down. Fourth, pull the fire handle. This shuts off the remaining supplies to that engine: the fuel low pressure valve, the bleed air, the hydraulic supply and the generator, and it arms the squibs on the fire bottles. Fifth, discharge the first bottle into the engine fire zone. If the warning is still lit after about thirty seconds, discharge the second bottle. Finally, land as soon as possible. The order matters: shut down the engine, pull the handle, then fire the extinguisher. Discharging first would waste the agent on a fire that is still being fed.
Part 3 · False warnings
False warnings and how the design fights them
Fire detectors
Smoke detectors
• short circuit in a resistive loop • chafed, kinked or crushed element • moisture in a connector • (one loop alone cannot fire the warning)
• dust and dirt in the chamber • condensation , steam, humidity • gases from cargo, e.g. rotting fruit • aerosol sprays, insects
Double loops AND logic: one damaged loop cannot trigger the fire warning.
Time delay Spot detectors wait about two seconds to ignore vibration.
Treat it as real A warning is a fire until proved otherwise; smoke detectors can be reset to confirm.
Chapter 19 · Smoke and Fire Detection
18
e-books by eatpl.in · © 2026 · Do not copy or distribute
False warnings are a real problem, so the designers work hard to avoid them. For fire detectors, the usual culprits are a short circuit in a resistive loop, an element that has been chafed, kinked or crushed during maintenance, or moisture in a connector. Smoke detectors are even more sensitive: dust and dirt in the chamber, condensation or steam, gases given off by cargo such as rotting fruit, aerosol sprays and even insects can all set them off. The defences are the double loop with AND logic, the time delay on spot detectors to ride out vibration, and the ability to reset a smoke detector to see whether the warning returns. But the rule in the air is simple: a warning is treated as a real fire until it is proved otherwise. Many accidents began with a crew deciding a warning was false.
Part 4 · Smoke detection
Smoke detectors watch where nobody can Used where a bay cannot be kept under constant watch Fitted in cargo holds , electrical and avionics bays and lavatories Not in the cabin or on the flight deck: crew can see and smell smoke there Give a remote warning on the flight deck, can be tested from there Can be reset after a warning to verify it
Where nobody can watch
main deck: cabin, flight deck crew can see and smell smoke here
lav lav
avionics
forward hold
aft hold
smoke detector: remote warning on the flight deck
tested from the flight deck; can be reset to confirm
cargo + avionics + lavatories (not cabin, not cockpit)
Chapter 19 · Smoke and Fire Detection
19
e-books by eatpl.in · © 2026 · Do not copy or distribute
Smoke detectors protect the places nobody can keep an eye on. A cabin crew member will see and smell smoke in the passenger cabin long before any detector could, and so will the pilots on the flight deck. But no one is sitting in the cargo hold, the electrical and avionics equipment bay, or inside a closed lavatory. So those are the places fitted with smoke detectors, usually several per compartment. Each system gives a remote warning on the flight deck. It can be tested from the flight deck, just like the fire detection. And after a warning, it can be reset, so the crew can see whether the warning comes back, which helps them decide whether it is real. For the exam, the list to remember is cargo bays, electrical equipment bays and toilets. The passenger cabin and the A P U compartment are not on that list.
Part 4 · Smoke detection
Four ways to sense smoke or flame Light detection A photocell sees the visible or infrared light of an open flame . Will not see a smouldering fire.
Light refraction (scatter) Smoke scatters a lamp beam onto a shielded photocell . The common optical type in holds and bays.
Ionisation A tiny radioactive source ionises the air; smoke particles capture ions and the ion current falls .
Semiconductor Heated elements absorb CO or nitrous gases ; their conductivity changes. Compares cabin with ambient air.
Chapter 19 · Smoke and Fire Detection
20
e-books by eatpl.in · © 2026 · Do not copy or distribute
Smoke and flame detectors work on four main principles. The light detection type is really a flame detector: a photoelectric cell responds to the visible light or infrared radiation from an open flame. The light refraction type, which the exam calls refraction but which really works by light scattering, uses a lamp and a photocell that is hidden from the beam; smoke scatters light onto the cell. This optical type is very common. The ionisation type uses a tiny radioactive source to make the air conduct; smoke reduces that current. And the semiconductor type uses heated solid state elements that absorb carbon monoxide or nitrous gases, changing their conductivity. So when a question asks what type smoke detectors are on aircraft, the answer is ionisation or optical. Let us look at each in more detail.
Part 4 · Optical smoke detector
The light refraction (light scatter) detector Compartment air is drawn through a dark chamber by a fan A projector lamp shines across it; the photoelectric cell is shielded from the beam Smoke particles reflect and refract light onto the cell: its current changes That triggers the visual and aural warning A test lamp shines on the cell when the test is selected; a variant senses beam dimming
air in to fan
light trap
projector lamp
photoelectric cell (shielded)
test lamp
smoke scatters light onto the cell
cell current changes → visual and aural warning
Chapter 19 · Smoke and Fire Detection
21
e-books by eatpl.in · © 2026 · Do not copy or distribute
The optical detector is called the light refraction type. A fan draws air from the compartment through a small, dark detection chamber. A projector lamp shines a beam across the chamber, and a photoelectric cell sits out of line with the beam, behind a shield, so in clean air no light reaches it. When smoke enters, the particles bend and bounce some of the light sideways, by refraction and reflection, and some of it lands on the cell. The cell's conductivity changes, the current through it changes, and the circuit triggers the visual and aural warning. When the crew select the test, a separate test lamp shines straight onto the cell, proving the cell and the warning circuit. A variant puts the cell directly in line with the lamp and senses the beam being dimmed by smoke; that needs more smoke to trigger. For the exam, remember that a smoke detector uses the refraction of light passing through smoke.
Part 4 · Ionisation detector
The ionisation smoke detector A tiny radioactive source bombards the oxygen and nitrogen molecules in the chamber The air is ionised , so a small current flows between two charged plates Smoke particles attach to the ions and slow them down The current falls ; the external circuit senses the drop and gives the warning Exam: detection works because the ion current is reduced by smoke
Clean air
Smoke
+ −
steady small current
ions captured: current ↓
alpha source (tiny radioactive pellet)
ionised O₂ and N₂ molecules
smoke particles grab the ions
Warning when the current FALLS below the set level
(a sealed reference chamber offsets pressure and humidity)
Chapter 19 · Smoke and Fire Detection
22
e-books by eatpl.in · © 2026 · Do not copy or distribute
The ionisation detector uses a tiny piece of radioactive material inside its chamber. Its alpha particles knock electrons off the oxygen and nitrogen molecules in the air, so the air contains positive and negative ions. Two plates with opposite charges sit either side, and the ions drift towards them, so a small, steady current flows across the chamber and through an external circuit. When smoke enters, the smoke particles attach themselves to the ions. Those heavy, sluggish particles move much more slowly, so the current falls. The circuit senses that drop and operates the aural and visual warning. Notice the direction: the warning comes from the current going down, not up. That is the exam answer: the detection of ions is reduced by smoke. Many designs add a sealed reference chamber with clean air, so that changes in cabin pressure or humidity do not upset the reading.
Part 4 · Other detectors
Flame detectors and semiconductor gas detectors Light (flame) detector : photocell responds to visible or infrared light from an open flame Semiconductor : two heated solid-state elements coated in semiconductorOne samples cabin air , the other ambient air The cabin element absorbs carbon monoxide or nitrous gases: its conductivity changes The outputs are compared ; a difference gives the warning
Light (flame) detection
Semiconductor
photocell sees visible light
or infrared / ultraviolet
needs an open flame
element 1 cabin air
element 2 ambient air
CO, nitrous gases
compare
outputs differ:
smoke / toxic gas warning
heated elements; absorbed gas
changes their conductivity
Chapter 19 · Smoke and Fire Detection
23
e-books by eatpl.in · © 2026 · Do not copy or distribute
Two more principles complete the set. The light detection type is a flame detector. Its photoelectric cell, or an infrared or ultraviolet sensor, watches the area, and when an open flame appears, the change in light or infrared radiation striking the cell changes the current and activates the warning. It needs a flame, so it will not see a smouldering fire. The semiconductor type uses two heated solid state elements, each coated in semiconductor material. One element samples the air in the cabin or compartment, and the other samples ambient air for comparison. If the first element absorbs carbon monoxide or nitrous gases from smoke, its conductivity changes, the two outputs no longer match, and the warning is triggered. Comparing two elements means that ordinary changes affecting both of them, such as temperature, are cancelled out.
Part 4 · Cargo holds
Cargo smoke detection Same principles, usually optical , with detectors in the hold ceiling Air may be drawn by fans from several sampling points to the detectors On modern aircraft the warning is a FIRE (or CARGO SMOKE) warning on the flight deck A matching fire protection system is installed: ventilation off, halon discharged Often two detectors must agree , like the engine loops
detectors in the hold ceiling (sampling air)
AFT CARGO SMOKE
treated as a fire: ventilation off, cargo bottle discharged
two detectors often must agree (AND logic), as on engines
Chapter 19 · Smoke and Fire Detection
24
e-books by eatpl.in · © 2026 · Do not copy or distribute
Cargo holds are the biggest spaces in the aircraft that nobody can see into, so they get a set of smoke detectors, usually optical, mounted in the hold ceiling. On some aircraft, fans draw air from several sampling points to the detectors, so a little smoke anywhere in the hold reaches them quickly. On modern aircraft, smoke in the hold is not treated as a mere advisory: the flight deck shows a fire warning, often worded as cargo smoke, with the master warning and the bell. A suitable fire protection system is installed to go with it. The crew shut off the ventilation to the hold and discharge halon into it, and we will look at that system in the next lesson. To reduce false alarms, many installations need two detectors in the same area to agree before the warning comes on, the same AND logic as the engine loops.
Part 4 · Lavatories
Lavatory smoke detection Aircraft with 20 or more passenger seats : every lavatory needs a smoke detector Warning: a light in the cockpit , or a light or horn in the cabin that cabin crew will notice Plus an automatic extinguisher in the waste bin (next lesson) Tampering with or disabling a lavatory smoke detector is prohibited Lavatories are a hidden risk: discarded cigarettes and paper towels
smoke detector
waste bin
automatic bottle
heat-sensitive tip
(next lesson)
LAV SMOKE
20 or more passenger seats: detector + automatic bin extinguisher
Chapter 19 · Smoke and Fire Detection
25
e-books by eatpl.in · © 2026 · Do not copy or distribute
Lavatories are a special case. A cigarette smoked in secret and dropped into the waste bin, full of paper towels, has started serious fires, and the door is closed, so no one sees it. That is why every lavatory on an aircraft with twenty or more passenger seats must have a smoke detector system. It must give a warning light in the cockpit, or a warning light or audible warning in the passenger cabin that a cabin crew member will readily notice; in practice most aircraft give both, with a horn and a flashing light at the lavatory and a message on the flight deck. The same rule also requires an automatic fire extinguisher in each waste bin, which we cover in the next lesson. Passengers are reminded in the safety briefing that tampering with or disabling a lavatory smoke detector is prohibited.
Summary
Smoke and fire detection: what to take away
Detect spot or continuous double loop, A AND B
Warn bell + steady red light overheat: amber only
Act shut down, pull handle, then discharge (crew)
Smoke scatter or ionisation cargo, avionics, lavs
Spot detectors Melting link: permanent warning. Differential expansion: resets, 2 s delay for vibration.
Fire wires Resistive: R falls with heat, short = false fire . Capacitive: C rises , short = no false fire. Gas: pressure rise, loss = fault .
Loops and test Double loop, A AND B ; single-loop fallback; test proves continuity; no test light = break .
Smoke Optical or ionisation ; cargo, avionics bays, lavatories; ionisation current falls with smoke.
Chapter 19 · Smoke and Fire Detection
26
e-books by eatpl.in · © 2026 · Do not copy or distribute
Let us pull it together. Fire detection is fitted in the designated fire zones, the engines and the A P U, with overheat detection in places such as the wheel wells and bleed ducts. Spot detectors include the melting link, which gives a permanent warning, and the differential expansion switch, which resets and has a short delay to ignore vibration. Fire wires watch their whole length: the resistive type has a negative coefficient of resistance, so a short gives a false fire warning; the capacitive type has a positive coefficient of capacitance, and a short does not; the gas filled type uses a pressure rise, and a broken tube gives a fault. Two loops must agree, the test proves continuity, and the warning is a bell and a steady red light, with amber for overheat. Smoke detectors are optical or ionisation, and they watch the cargo holds, avionics bays and lavatories.