Welcome to fire protection and extinguishing. In the last lesson the aircraft found its fire; now we put it out. We will see how the engine and A P U fire bottles are built, how the crew arm and fire them, and how they can tell a bottle has gone, including the red disc that shows a bottle has discharged itself overboard. We will look at cargo hold suppression, the automatic extinguisher in every lavatory waste bin, and the classes of cargo compartment. Then we turn to the agents themselves, halon, water, dry powder, carbon dioxide, foam and sand, which one to use on which fire, and how many hand-held extinguishers an aircraft must carry. Let us begin.
Roadmap
Fire protection: the plan 1 · Fires and agents Fire classes , how agents work, and the three kinds of system .
2 · Fixed systems Engine bottles and squibs , discharge, indications , thermal discharge; APU ; cargo ; lavatory .
3 · The agents Halon 1211 and 1301 , water, dry powder, CO₂, foam, sand; colours; which agent for which fire .
4 · In the cabin How many hand-held extinguishers , halon units and crash axes ; fighting a cabin fire.
Chapter 20 · Fire Protection and Extinguishing
2
e-books by eatpl.in · © 2026 · Do not copy or distribute
Here is the plan for this lesson. Part one sets the scene: the classes of fire, the four ways an extinguishing agent can work, and the three kinds of extinguishing system an aircraft uses. Part two covers the fixed systems: the engine fire bottles with their squibs and spray rings, how the crew discharge them and how everyone can tell that a bottle has gone, including a thermal discharge overboard. Then the A P U, the cargo holds with their compartment classes, and the lavatory waste bin. Part three is about the agents themselves, halon, water, dry powder, carbon dioxide, foam and sand, with their colours and the all-important question of which agent to use on which fire. Part four brings us into the cabin: how many hand-held extinguishers and crash axes the regulations require, with worked examples.
Part 1 · Classes of fire
Classes of fire and the agents that suit them Class Burning material Use Never use A Solids: paper, wood, fabric, seat cushions (glowing embers) Water or water/glycol to cool; halon 1211— B Flammable liquids: fuel, oil, hydraulic fluid, paint Foam , dry powder, CO₂, halonWater (spreads the fire)C Gases: propane, butane, methane Dry powder (shut off the gas first)Water jet D Metals: magnesium, titanium (wheels, engine parts) Sand or special dry powderWater , CO₂, foamElectrical Live wiring, avionics, galley equipment Halon 1211 (BCF) , CO₂; isolate powerWater , water/glycol, foamWheel / brake Hot brakes, hydraulic fluid, tyre Dry powder Water or a CO₂ jet on the hot wheel
European classes A to D; in the US scheme class C means electrical , so read the question carefully.
Chapter 20 · Fire Protection and Extinguishing
3
e-books by eatpl.in · © 2026 · Do not copy or distribute
Fires are grouped by what is burning, because that decides what will put them out. Class A fires involve ordinary solids such as paper, wood, fabric and seat cushions. They leave glowing embers, so they need cooling, and water is best. Class B fires are flammable liquids such as fuel, oil and hydraulic fluid. Water would just spread the burning liquid, so we smother them with foam, dry powder, carbon dioxide or halon. Class C, in the European scheme, covers gases such as propane; shut off the gas and use dry powder. Class D is burning metal, such as magnesium wheels or titanium engine parts. Water makes these fires violently worse, so we use sand or a special powder. Electrical fires need a non-conducting agent: halon or carbon dioxide, never water. And wheel and brake fires get dry powder. Beware: in the American scheme, class C means electrical.
Part 1 · How agents work
Four ways to put a fire out
chain reaction
FUEL HEAT OXYGEN
cooling → heat
smothering → oxygen
starving → fuel
halon → chain reaction
Cooling Take away the heat . Water soaks solids and stops re-ignition.
Smothering Take away the oxygen . Foam , CO₂ , dry powder and sand blanket the fire.
Starving Take away the fuel . Fire handle: fuel, hydraulic and bleed valves shut.
Chain breaking Halon interferes chemically with combustion: fast knock-down, no residue.
Chapter 20 · Fire Protection and Extinguishing
4
e-books by eatpl.in · © 2026 · Do not copy or distribute
Every extinguishing method attacks one side of the fire triangle, or the chain reaction in the middle. Cooling removes the heat. Water is the classic cooling agent, and because it soaks into solids, it also stops them re-igniting. Smothering removes the oxygen. Foam lays a blanket over a burning liquid, carbon dioxide pushes the air away, and dry powder and sand cover the fuel. Starving removes the fuel itself, and that is exactly what the engine fire handle does: it closes the fuel, hydraulic and bleed valves to that engine, so the fire is no longer fed. Finally, halons work chemically. They interrupt the chain reaction of combustion, which is why a small amount knocks a fire down so quickly and leaves no residue. That chemical action is the main reason halons have been the aircraft agent of choice for so long.
Part 1 · Types of system
Fixed, portable and mixed systems
engine
bottles + pipes + spray rings
hand-held, carried to the fire
baggage compartment
hand unit into an adapter point
Fixed Bottles fixed to the structure, piped to engines and APU ; on large aircraft also cargo holds and gear bays.
Portable Hand-held extinguishers for fires in the flight deck and passenger cabin .
Mixed Pipes and spray rings in a baggage compartment, fed by a hand unit plugged into an adapter point .
Chapter 20 · Fire Protection and Extinguishing
5
e-books by eatpl.in · © 2026 · Do not copy or distribute
Aircraft use three kinds of extinguishing system. A fixed system has containers of agent fixed to the structure, with distribution pipes and controls, and it protects the power plants and, where fitted, the A P U. On large aircraft, fixed systems may also protect the cargo holds and the landing gear bays. A portable system is simply the set of hand-held extinguishers carried in the flight deck and the passenger cabin, for a crew member to take to the fire. A mixed system is a halfway house used on some aircraft for baggage and service compartments: distribution pipes and spray rings are built into the compartment, but there is no bottle on them. Instead, a crew member plugs a hand-held or mounted extinguisher into a special adapter point and discharges it through the pipes. So you can fight a fire in a compartment you cannot open.
Part 2 · Engine fire extinguishing
Engine fire bottles, squibs and spray rings
1
2
ENGINE
halon 1301 + nitrogen
squib (cartridge)
pressure switch → DISCH light
spray ring
spray ring
fire zone: between engine and cowl
Chapter 20 · Fire Protection and Extinguishing
6
e-books by eatpl.in · © 2026 · Do not copy or distribute
Here is a typical engine fire extinguishing system. The extinguishant is stored in fire bottles, usually two per engine, filled with liquid halon 1301 and pressurised with nitrogen. On some twins, two bottles are shared, and each can be fired into either engine. Between each bottle and its pipe sits a discharge head with a squib, an electrically fired explosive cartridge. Pipes run from the bottles into the nacelle and end in spray rings or nozzles that surround the engine casing. Once the engine has been shut down and the fuel cut off, the crew discharge the first bottle. The squib fires, breaks the seal, and the nitrogen drives the agent through the pipes and out of the spray rings, filling the space round the engine. If the warning is still on after about thirty seconds, they discharge the second bottle. With the fuel stopped and the zone flooded, the fire goes out.
Part 2 · Inside the bottle
Anatomy of a fire bottle A steel sphere or cylinder of liquid halon , pressurised by nitrogen Discharge head : an electrically fired squib (cartridge) breaks a frangible disc Pressure gauge and a pressure switch that sees the dischargeThermal relief : a fusible plug or bursting (burster) disc vents excess pressure overboardExcess pressure from heat is relieved through burster discs , not the delivery pipes
nitrogen
propellant (several hundred psi)
liquid halon 1301
discharge head: squib fires, frangible disc breaks
to spray rings
gauge
+ pressure switch
thermal relief:
fusible plug / bursting disc
red disc on skin
Chapter 20 · Fire Protection and Extinguishing
7
e-books by eatpl.in · © 2026 · Do not copy or distribute
Let us open up a fire bottle. It is a steel sphere or cylinder containing liquid halon, with nitrogen above it at several hundred p s i. The nitrogen is the propellant, so the bottle empties in a second or two. The outlet is closed by a discharge head. Inside the head, a thin frangible disc seals the bottle, and next to it sits the squib, an electrically fired cartridge. When the squib fires, it ruptures the disc and the agent rushes out to the pipes. The bottle also carries a pressure gauge for the ground engineers, and a pressure switch that senses the discharge and lights the flight deck indication. Finally, there is a safety outlet. If the bottle gets too hot, its pressure climbs dangerously, so a fusible plug or bursting disc lets go and vents the contents overboard. So excess pressure in a fixed system is relieved through burster discs.
Part 2 · Firing the bottle
Arming and firing: SQUIB, AGENT and DISCH Engine shut-down drill completed first Fire handle pulled: the squib is armed (SQUIB light on the agent button) Press AGENT : the cartridge fires and agent under pressure goes to the spray rings A low pressure switch then lights DISCH on the button Squibs are powered from the hot battery (vital DC) bus , so they always work
1 · armed
2 · press
3 · discharged
AGENT 1 SQUIB DISCH
AGENT 1 SQUIB DISCH
AGENT 1 SQUIB DISCH
fire handle pulled: squib armed and tested
squib fires: cartridge breaks the bottle seal
pressure in the line trips the switch
• Squibs are fed from the hot battery (vital DC) bus
so the bottles fire even with every generator lost
• Older types: an indicator fuse (clear bulb turns red)
• Second bottle: same arming, button and indication
Chapter 20 · Fire Protection and Extinguishing
8
e-books by eatpl.in · © 2026 · Do not copy or distribute
How does the crew fire the bottle? First, the engine shut down drill must be complete. Pulling the fire handle arms the electrical cartridge between the base of the bottle and the pipe, and on Airbus aircraft a SQUIB light in the agent push button confirms it is armed and that its circuit is good. Pressing the AGENT button fires the cartridge, and the agent, under pressure, goes to the spray rings in the engine. As the bottle empties, its pressure falls, a low pressure switch operates and the DISCH caption lights in the button: that bottle is gone. If the fire persists, the second bottle is armed and fired in exactly the same way. Older aircraft may show the discharge with an indicator fuse, a small clear bulb that turns red. The squibs are fed from the hot battery bus, the vital D C bus, so they can be fired even if every generator has failed.
Part 2 · A handle-type system
Rotate-to-discharge: a typical drill On many types one fire handle does it all. Example for a left engine fire with two shared bottles:
Step Action What it does 1 Close the left thrust leverEngine to idle 2 Left HP / start lever close Engine shut down 3 Pull No 1 fire handleIsolates fuel, bleed, hydraulics, generator; arms the squibs 4 Rotate the handle left to the stop, hold 1 sLeft bottle discharges into the left engine 5 After 30 s , still lit? Rotate right , hold 1 s Right bottle also discharges into the left engine 6 Land as soon as possible—
An example only: always fly the checklist for your aircraft type.
Chapter 20 · Fire Protection and Extinguishing
9
e-books by eatpl.in · © 2026 · Do not copy or distribute
On many aircraft the fire handle does everything, and here is a representative drill for a left engine fire with two bottles shared between the engines. First, close the left thrust lever. Second, close the left H P or start lever, which shuts the engine down. Third, pull the number one fire handle. That isolates the fuel, bleed air, hydraulics and generator of the left engine and arms the squibs. Fourth, rotate the handle to the left, to its mechanical limit, and hold it for at least one second. That discharges the left bottle into the left engine. Fifth, if after thirty seconds the fire warning is still on, rotate the same handle to the right and hold it for a second: now the right bottle also discharges into the left engine. And sixth, land as soon as possible. This is an example; always follow the checklist for your type.
Part 2 · Has it fired?
How to tell a bottle has been discharged
DISCH
flight deck light
indicator pin out
0
gauge reads zero
thermal discharge: red disc shows
Flight deck DISCH or bottle low-pressure light; on older types an indicator fuse .
Indicator pin A pin protrudes from the bottle head after firing.
Pressure gauge Reads zero . Both may need a panel opened to see.
Thermal discharge Overheated bottle vents overboard: green disc ejected, red disc shows.
Chapter 20 · Fire Protection and Extinguishing
10
e-books by eatpl.in · © 2026 · Do not copy or distribute
How does anyone know a bottle has fired? On the flight deck, the DISCH light or a bottle low pressure light comes on, operated by the pressure switch, and older aircraft use an indicator fuse that turns red. On the bottle itself there are physical indications for the engineers. An indicator pin protrudes from the discharge head once the squib has fired, and the pressure gauge reads zero. These may be hidden, so a panel may have to be opened to see them. A different case is the thermal discharge. If the bottle has been overheated, for example by a fire in its bay, it vents its contents overboard through its safety outlet, and on the way out the agent blows a green disc out of the fuselage skin, leaving a red disc showing. So a red indicator on the walk round means a bottle has discharged because of over temperature or over pressure.
Part 2 · Thermal discharge
Over-temperature: the red disc An overheated bottle builds up a dangerous pressure The fusible plug or bursting disc lets go before the bottle can burst The agent is dumped overboard through a pipe to the skin It blows out a green disc ; a red disc now shows outside Some types also show a yellow disc for a normal discharge
fuselage skin
BOTTLE temperature ↑ pressure ↑
bursting disc / fusible plug
agent dumped overboard
green disc blown out →
red disc now shows
Seen on the walk-round:
bottle empty, gauge at zero
Chapter 20 · Fire Protection and Extinguishing
11
e-books by eatpl.in · © 2026 · Do not copy or distribute
Fire bottles live near hot engines, and a bottle that gets too hot builds up a dangerous pressure. Rather than let it burst, its fusible plug or bursting disc gives way first, and the agent is dumped overboard through a pipe to the skin. On its way out, the agent blows a green disc out of the fuselage, and a red disc now shows behind it. So a missing green disc and a red one showing on the walk round tell you that a bottle has had a thermal discharge, and it is empty. The gauge would read zero. Some types use a second, yellow disc that is blown out by a normal discharge from the flight deck, so the ground crew can tell the two cases apart. For the exam, an engine bottle that has discharged because of over temperature is shown by an externally mounted discharge indicator showing red.
Part 2 · What the bottle can reach
Round the engine, not inside it Agent floods the fire zone between the engine casing and the cowling That is where fuel, oil and hydraulic leaks can meet hot surfaces It does not reach the gas path inside the engine Internal or tailpipe fire : fuel off, then motor the engine on the starter Shut off and isolate first , or the fire just re-lights
gas path (core): not reached
gearbox
agent floods the zone round the engine
engine casing
Fixed bottles : fuel, oil and hydraulic leaks in the nacelle
Tailpipe (internal) fire : fuel off, then motor
the engine with the starter to blow it out
Chapter 20 · Fire Protection and Extinguishing
12
e-books by eatpl.in · © 2026 · Do not copy or distribute
It is important to understand what the fire bottles can and cannot reach. The fire zone is the space inside the nacelle, between the engine casing and the cowling. That is where the fuel pipes, the oil and hydraulic lines, the accessory gearbox and the fire loops sit, and where a leak can meet a hot casing. The spray rings flood that space with agent. They do not spray into the gas path through the middle of the engine. So activating the fixed engine fire system puts out fires around the engine, but not within it. A fire inside the engine, such as a tailpipe fire during a start on the ground, is dealt with differently: the fuel is shut off and the engine is motored on the starter to blow the fire out. And remember why the drill shuts everything off first: an extinguished fire that is still being fed fuel will simply re-ignite.
Part 2 · APU
Auxiliary power unit protection A self-contained, constant-speed gas turbine in the tail; usable in flight when certified Behind a firewall , with fire loops and its own fire bottle Self-monitoring : automatic shutdown for fire (and auto bottle discharge), oil pressure loss , overspeed , overheat A manual control panel is still fitted on the flight deck External panel with horn: ground crew can shut down and discharge
firewall
APU
fire loops
bottle
Automatic shutdown for:
• fire (and the bottle fires automatically)
• oil pressure loss · overspeed · overheat
Plus a manual control panel, and an external
panel with horn for the ground crew
Self-contained, constant-speed gas turbine
bleed air, electrics (and on some types hydraulics)
Chapter 20 · Fire Protection and Extinguishing
13
e-books by eatpl.in · © 2026 · Do not copy or distribute
The auxiliary power unit is a small, self-contained, constant speed gas turbine in the tail cone. It takes fuel from the aircraft system and provides bleed air and electrical power, and on some types hydraulic power, and when certified it can be used in flight. Like an engine, it sits in a designated fire zone behind a firewall, with its own fire loops and fire bottle. The difference is that the A P U looks after itself. It shuts down automatically in the event of a fire, and on many aircraft it also fires its own bottle automatically, especially on the ground when the A P U may be running with no one on the flight deck. It also shuts down for loss of oil pressure, overspeed and overheat. A manual control panel is still fitted on the flight deck, and an external panel near the landing gear, with a warning horn, lets the ground crew shut it down and fire the bottle.
Part 2 · Cargo holds
Cargo fire suppression On smoke, the crew shut off ventilation and heating to the hold Halon 1301 is fired from the flight deck into the holdA first bottle gives a fast knock-down ; a second, metered one holds the concentration The fire is suppressed , not necessarily out: divert and land Large aircraft may also have fixed protection for wheel bays
Halon concentration in the hold
minimum to keep the fire suppressed
1: fast knock-down
2: metered, held for the diversion
smoke!
time →
• Ventilation and heating to the hold shut off
• Agent: halon 1301 , fired from the flight deck
• Fire is suppressed, not always put out: land soon
Chapter 20 · Fire Protection and Extinguishing
14
e-books by eatpl.in · © 2026 · Do not copy or distribute
If smoke is detected in a cargo hold, the crew first shut off the ventilation and heating to that hold, so the fire is not fed fresh air and the agent is not blown away. Then they fire halon 1301 into the hold from the flight deck. A typical system uses a first bottle that empties quickly to knock the fire down, followed by a second bottle that is metered in slowly to hold the halon concentration up for the rest of the diversion, which may last an hour or more. In this scene the aft hold is on fire; on many aircraft the same bottles can be directed to either hold. The important point is that a deep seated cargo fire may only be suppressed, not put out, so the crew divert and land as soon as possible. On large aircraft, fixed systems may also protect the landing gear bays.
Part 2 · Compartment classes
Cargo compartment classes A to E Class Key features A Fire seen by a crew member at their station; every part accessible in flight ; hand extinguisher available B Crew can reach all parts in flight with a hand extinguisher and move the contents by hand; no hazardous smoke into occupied areas when opened; separate smoke or fire detector warning at the pilot's station; hand extinguishers available C Not accessible: separate detector warning to the flight deck; built-in extinguishing system controlled from the flight deck; smoke excluded from occupied areas; ventilation controlled D Fire completely confined without danger to the aircraft: smoke excluded, ventilation limited so the fire cannot progress beyond safe limits, fire-resistant lining (older designs) E Cargo-only aeroplanes: detector; ventilation can be shut off from the cockpit ; smoke kept out of the cockpit; crew emergency exits accessible under all loading conditions
The flight deck and cabin are like class A spaces: a crew member can see, reach and fight a fire there.
Chapter 20 · Fire Protection and Extinguishing
15
e-books by eatpl.in · © 2026 · Do not copy or distribute
Cargo compartments are certified in classes A to E, according to how a fire would be found and fought. In a class A compartment, a crew member at their station would see a fire, and every part can be reached in flight, with a hand extinguisher available. Class B compartments are accessible in flight, so a crew member can reach every part with a hand extinguisher and move the contents by hand; they also need a separate smoke or fire detector giving a warning at the pilot's station. A class C compartment cannot be reached in flight, so it needs a detector warning on the flight deck and a built-in extinguishing system controlled from there, plus control of ventilation and exclusion of smoke from the cabin. Class D compartments, found on older designs, confine the fire by starving it of air inside a fire-resistant lining. And class E is the main deck of a cargo-only aeroplane, where the ventilation can be shut off from the cockpit.
Part 2 · Lavatories
The automatic waste-bin extinguisher Required on aircraft with 20 or more passenger seats A small halon bottle under the basin, piped to the waste bin Its nozzles are sealed with a fusible plug (low melting point alloy) A bin fire melts the seal and the agent discharges automatically The only fully automatic extinguisher in the cabin; a smoke detector is also required
wash basin
halon bottle
waste bin (paper towels)
nozzles sealed with a low melting point alloy
fully automatic:
heat melts the seal
no crew action
Chapter 20 · Fire Protection and Extinguishing
16
e-books by eatpl.in · © 2026 · Do not copy or distribute
Every lavatory waste bin on an aircraft with twenty or more passenger seats must have its own built-in fire extinguisher. A small halon bottle, sometimes called the potty bottle, sits under the wash basin, and its outlet tubes end inside the bin. The ends of the tubes are sealed with a fusible plug of low melting point alloy, typically melting at about eighty degrees. If a cigarette sets the paper towels alight, the heat melts the seal and the agent discharges straight into the bin automatically, with no action by anyone. That makes it the only fully automatic extinguisher in the cabin, and the exam answer to how it is activated is: by high temperature in its vicinity. The lavatory must also have a smoke detector, as we saw in the last lesson, so the crew are alerted and can check the compartment with a hand extinguisher.
Part 3 · The agents
Extinguishing agents compared Agent Container Where used Key points Halon 1211 (BCF) Red (older: green, purple, brown) Hand-held , cabin and flight deckElectrical and liquid fires; chain-breaking; no residue; prevents re-flash Halon 1301 (BTM) Grey Fixed : engines, APU, cargoVery low toxicity; vapour, hard to aim Water / water-glycol Red Cabin, hand-held Class A only; glycol works to −20 °C ; never on electrical or liquid fires Dry powder Blue, or red with blue label Ground; not in pressurised cabins Liquids, wood, paper; best for wheels and brakes ; no cooling; ruins visibility CO₂ Black, or red with black label Ground, engines on the ground Smothers; safe for engines; can suffocate; cold; not used in cabins Foam Cream, or red with cream label Ground Principal agent for fuel spills ; blanketsSand Bucket Ground Metal fires (magnesium, titanium)Methyl bromide — Old engine systems Toxic and corrosive; phased out
Chapter 20 · Fire Protection and Extinguishing
17
e-books by eatpl.in · © 2026 · Do not copy or distribute
Here are the agents side by side. Halon 1211, called B C F, is the hand-held agent in the cabin and on the flight deck; it is very effective on electrical and liquid fires and leaves no residue. Halon 1301, called B T M, is used in fixed systems for engines, the A P U and cargo holds; it has very low toxicity, but as a vapour it is hard to aim. Water, or water with glycol as antifreeze down to minus twenty, is for class A fires in the cabin, and must never be used on electrical or liquid fires. Dry powder is not allowed in the crew or passenger compartments of pressurised aircraft, because it destroys visibility and can ruin electronics, but it is the agent for wheels and brakes. Carbon dioxide smothers fires and is kind to engines, but it can suffocate people. Foam is the principal agent for fuel spills, sand is for metal fires, and methyl bromide is an old, toxic engine agent.
Part 3 · Halons
Halon 1211 and halon 1301 BCF = bromochlorodifluoromethane = halon 1211 : hand-heldBTM = bromotrifluoromethane = halon 1301 : fixed systemsWork by a heavy blanketing mist and, above all, chemical interference with combustion Colourless, non-corrosive , evaporate leaving no residue ; no cold burns Halogenated hydrocarbons, called "Freon" : the engine fire agent
Halon number = atoms of C · F · Cl · Br
1 2 1 1
BCF
1 3 0 1
BTM
bromochlorodifluoromethane hand-held: liquid jet, easy to aim
bromotrifluoromethane fixed systems: vapour, floods a space
• Breaks the chain reaction and blankets the fire
• Colourless, no residue , non-corrosive, low toxicity
• No cold burns; outstanding at preventing re-flash
• Both used in HRD (high rate discharge) engine systems
• Halogenated hydrocarbons, often called "Freon"
Halon harms the ozone layer: no new production;
newer aircraft use halon-free bin and hand units
Chapter 20 · Fire Protection and Extinguishing
18
e-books by eatpl.in · © 2026 · Do not copy or distribute
Halons are the agents you meet most in aircraft. The number tells you the recipe: the four digits count the atoms of carbon, fluorine, chlorine and bromine. Halon twelve eleven is bromochlorodifluoromethane, or B C F. It comes out of a hand extinguisher as a liquid stream that you can aim at a fire from a safe distance, and it is the standard cabin and flight deck extinguisher. Halon thirteen oh one is bromotrifluoromethane, or B T M. It turns to vapour readily and floods a space, which is ideal for engine bays, the A P U and cargo holds, but makes it hard to direct by hand. Both form a blanketing mist, but their real strength is that they interfere chemically with the combustion process. They are colourless, non-corrosive, leave no residue and are outstanding at preventing re-flash. This family is often called Freon, which is the exam answer for an engine fire agent.
Part 3 · Container colours
Know the extinguisher by its colour
European scheme: red body, coloured band (older units were painted all over in the band colour)
Water / glycol cabin: paper, fabric Foam fuel spills (ground) Dry powder wheels, brakes (ground) CO₂ electrical (ground) Halon 1211 (BCF) cabin, flight deck SAND Sand metal fires
Reference colours: BCF signal red (or green, purple, brown) · BTM grey · water red · dry powder blue · CO₂ black · foam cream.
Chapter 20 · Fire Protection and Extinguishing
19
e-books by eatpl.in · © 2026 · Do not copy or distribute
Extinguishers are colour coded so that, in an emergency, you pick up the right one. Under the current European scheme, all extinguishers have a red body with a coloured band or label. Older extinguishers were painted all over in the colour of their agent, and you will still see both. Water, or water glycol, is plain red. Foam has a cream band. Dry powder is blue, or red with a blue label. Carbon dioxide is black, or red with a black label, and you will recognise it by its horn shaped nozzle. Halon twelve eleven, B C F, is green on the modern scheme; older B C F units were signal red, green, purple or brown. The fixed halon thirteen oh one bottles are grey. And for metal fires there is a bucket of sand. Learn these: the exam does ask about container colours.
Part 3 · Choosing the agent
Which agent for which fire Fire Best agent Why Engine (fixed system) Halon 1301 / Freon Floods the nacelle, no damage; CO₂ on the ground also safe for engines Fuel or liquid spill Foam (also powder, CO₂, BCF)Blanket keeps oxygen away from the liquid Electrical BCF or CO₂Non-conducting; never water or water-glycol Cabin furnishings, paper Water / water-glycol (or BCF)Cools and soaks: stops re-ignition Wheel / brake Dry powder ; if none, sand No cooling, so no thermal shock or wheel burst Magnesium, titanium Sand or special dry powderWater reacts violently Propane, gas Dry powder Smothers; shut off the gas Carburettor / induction CO₂ or BCF Gas agents reach into the intake, no residue
Chapter 20 · Fire Protection and Extinguishing
20
e-books by eatpl.in · © 2026 · Do not copy or distribute
Now the question the exam loves: which agent for which fire? For an engine fire, the fixed system uses halon thirteen oh one, often just called Freon; on the ground, carbon dioxide is also safe for engines. For a fuel or other liquid spill, foam is the principal agent, although powder, carbon dioxide and B C F work too. For an electrical fire, use B C F or carbon dioxide, never water. For cabin furnishings and paper, water or water glycol cools and soaks the fire. For wheel and brake fires, dry powder, and if there is none, sand, because neither cools the wheel suddenly. Magnesium and titanium need sand or a special powder; water reacts violently. A gas fire such as propane needs dry powder, after shutting off the gas. And a carburettor or induction fire is fought with carbon dioxide or B C F, which reach into the intake and leave no residue.
Part 3 · Wheels and brakes
Wheel and brake fires Use dry powder : it smothers with no cooling effect Sudden cooling of a hot wheel can cause thermal shock , distortion and a wheel or tyre burst Never water ; CO₂ only as a last resort, blanketing alongside the wheel, not on itNo dry powder: sand smothers without cooling Approach from the front or rear , never in line with the axle
DANGER DANGER
approach from front or rear
Dry powder : no cooling, no thermal shock ·
No water on hot wheels
Chapter 20 · Fire Protection and Extinguishing
21
e-books by eatpl.in · © 2026 · Do not copy or distribute
Wheel and brake fires deserve their own slide. After a heavy braking or rejected take-off, the brakes can be glowing hot, and hydraulic fluid or grease may catch fire. The danger is not just the fire: if a very hot wheel is cooled suddenly, the thermal shock can distort or crack it and the tyre or wheel can burst violently. So the agent of choice is dry powder. It smothers the fire but, being a powder, has no cooling effect, which reduces the risk of a wheel explosion. Never use water. Carbon dioxide is very cold, so if it has to be used it is discharged alongside the wheel to blanket it, never straight onto it. If there is no dry powder, sand is the next best choice, for the same reason. And always approach a hot wheel from the front or rear, because a bursting wheel throws its pieces outward, sideways in line with the axle.
Part 4 · Hand-held extinguishers
How many hand-held extinguishers? Set by the maximum approved passenger seating configuration , i.e. the number of seats , not passengers on board:
Passenger seats Minimum in the cabin Of which halon 1211 (BCF) 7 to 30 1 — 31 to 60 2 at least 1 61 to 200 3 at least 2 201 to 300 4 at least 2 301 to 400 5 at least 2 401 to 500 6 at least 2 501 to 600 7 at least 2 601 or more 8 at least 2
Plus at least one BCF on the flight deck , one in each galley not on the main deck, and one in each accessible class A, B or E cargo compartment.
Chapter 20 · Fire Protection and Extinguishing
22
e-books by eatpl.in · © 2026 · Do not copy or distribute
How many hand-held extinguishers must an aircraft carry? The number depends on the maximum approved passenger seating configuration, which means the number of seats, not the number of passengers on today's flight and not the number of crew. From seven to thirty seats you need one in the passenger compartment. Thirty one to sixty: two. Sixty one to two hundred: three. Then add one for every extra hundred seats: four up to three hundred, five up to four hundred, six up to five hundred, seven up to six hundred, and eight above that. Of the cabin extinguishers, at least two must be halon twelve eleven, B C F, once you have sixty one seats or more, and at least one from thirty one to sixty. On top of these, there must be at least one B C F conveniently placed on the flight deck, and further units in galleys away from the main deck and in accessible cargo compartments.
Part 4 · Worked examples
Applying the rules Count seats , find the band, then add the flight deck unit.
25 seats Cabin: 1 . Flight deck: 1 BCF. Lavatory bin extinguisher and smoke detector: yes (20 or more). Crash axe or crowbar: 1.
70 seats 61–200 band: cabin 3 , of which at least 2 BCF . Plus 1 on the flight deck: 4 in all.
186 seats Still 61–200: cabin 3 (at least 2 BCF) + flight deck 1. Crash axe: 1 , on the flight deck.
520 seats 501–600 band: cabin 7 (at least 2 BCF) + flight deck 1. Crash axes: 2 (flight deck + rear galley).
Chapter 20 · Fire Protection and Extinguishing
23
e-books by eatpl.in · © 2026 · Do not copy or distribute
A twenty five seat aircraft is in the seven to thirty band, so it needs one extinguisher in the cabin and one on the flight deck. Because it has twenty or more seats, each lavatory needs a smoke detector and an automatic waste bin extinguisher. A seventy seat turboprop is in the sixty one to two hundred band: three in the cabin, of which at least two must be B C F, plus one on the flight deck, so four in all. A one hundred and eighty six seat jet is still in the same band, so it also needs three in the cabin plus one on the flight deck, and since it has no more than two hundred seats, one crash axe or crowbar on the flight deck. A five hundred and twenty seat aircraft is in the five hundred and one to six hundred band: seven in the cabin, at least two of them B C F, one on the flight deck, and two crash axes.
Part 4 · Crash axe and crowbar
Crash axes, crowbars and gloves Aeroplanes over 5700 kg or with more than 9 passenger seats : one crash axe or crowbar on the flight deck More than 200 seats : another in or near the rearmost galley Used to reach fires in inaccessible places (behind panels) and as a general evacuation tool Insulated handle; kept out of sight of passengers Fire-resistant (Nomex) gloves protect hands from hot materials when firefighting
crash axe
insulated handle
crowbar
> 5700 kg or > 9 seats: one on the flight deck
> 200 seats: another in or near the rearmost galley
Chapter 20 · Fire Protection and Extinguishing
24
e-books by eatpl.in · © 2026 · Do not copy or distribute
The crash axe and the crowbar are firefighting tools as much as rescue tools. A fire in the cabin often starts behind a sidewall panel, in the ceiling or under the floor, where wiring runs. The crew cannot fight what they cannot reach, so they use the axe or crowbar to open the panel, and then the extinguisher. The same tools help in an evacuation, for example to free a jammed exit or break through. The rule is that any aeroplane with a maximum take off mass over five thousand seven hundred kilograms, or with more than nine passenger seats, must carry at least one crash axe or crowbar on the flight deck. With more than two hundred seats, a second one goes in or near the rearmost galley. They have insulated handles and are stowed out of passengers' sight. Fire-resistant gloves, often made of Nomex, are also provided to protect the hands from hot materials while fighting a fire.
Part 4 · Fighting a cabin fire
Fighting a fire in the cabin Find it Locate the source ; feel panels for heat; use the axe or crowbar to reach hidden fires.
Protect yourself Put on smoke hood / PBE and fire gloves before closing in.
Fight it BCF at the base of the flames, from about 2 m; water on embers of paper and fabric.
Isolate Galley or electrical fire: switch off the power first.
Communicate Tell the flight crew at once : location, smoke, progress.
Follow up Watch for re-ignition ; ventilate after halon; land as soon as possible if in doubt.
Chapter 20 · Fire Protection and Extinguishing
25
e-books by eatpl.in · © 2026 · Do not copy or distribute
Finally, how is a cabin fire fought? It is a team effort. One crew member fights the fire, another brings more extinguishers and protective equipment, and a third keeps the flight crew informed. First, find the source; smoke may come out of a vent far from the fire, so feel panels for heat and use the crash axe to reach a hidden fire. Put on the smoke hood, or protective breathing equipment, and fire gloves before closing in. Aim the B C F at the base of the flames from about two metres and sweep. On burning paper or fabric, follow up with water to cool the embers. For a galley or electrical fire, isolate the power first. Tell the flight crew immediately and keep updating them, because they decide whether to divert. Afterwards, watch the area for re-ignition. If there is any doubt, the safest course is to land as soon as possible.
Summary
Fire protection: what to take away
Engines · APU · Cargo fixed halon 1301 (BTM) squib · DISCH · red disc
Cabin · flight deck halon 1211 (BCF), water number set by seats
Wheels · brakes dry powder never water
Metal fires sand (or special powder)
Engine bottles Halon 1301 + N₂; squib ; DISCH light; pin , gauge; thermal discharge = red disc ; burster discs relieve pressure.
APU, cargo, lav APU auto shutdown (fire, oil, overspeed, overheat); cargo halon , ventilation off; lav bin automatic (20+ seats).
Agents BCF hand-held; water class A; foam fuel; dry powder brakes; sand metals; CO₂ ground; Freon engines.
Numbers 7–30: 1 · 31–60: 2 · 61–200: 3 (2 BCF) · +1 per 100 to 8; plus 1 on the flight deck. Axe: flight deck; >200 seats: +1.
Chapter 20 · Fire Protection and Extinguishing
26
e-books by eatpl.in · © 2026 · Do not copy or distribute
Let us pull it all together. Engine fire bottles hold halon thirteen oh one pressurised with nitrogen, fired by a squib once the engine is shut down and isolated. The DISCH light, a protruding pin and a zero gauge show a discharge, and a red disc on the skin shows a thermal discharge through the burster disc. The agent floods the zone round the engine, not the core. The A P U shuts itself down for fire, oil pressure loss, overspeed and overheat. Cargo holds get halon with the ventilation off, and the lavatory bin extinguisher works automatically on heat. B C F is the hand-held agent, water is for class A, foam for fuel, dry powder for brakes, sand for metals and Freon for engines. And the numbers: one, two, three, then one more per hundred seats up to eight, at least two B C F from sixty one seats, plus one on the flight deck.