In the last lesson we built a hydraulic system from six simple parts. Now we open them up. How does a pump control its own pressure? What does a cut-out valve do, and why does it need an accumulator? Why does an accumulator gauge read system pressure and not its pre-charge? How can a jack be locked by nothing but trapped oil? And how do the many valves, from relief valves to shuttle valves and fuses, keep the system safe? We finish with the way a modern airliner combines several independent systems, a power transfer unit and a ram air turbine.
Roadmap
Inside the hydraulic system 1 · Pumps Hand pumps, constant-delivery gear pumps and constant-pressure swash-plate pumps.
2 · Cut-out and accumulators The ACOV , accumulator functions, pre-charge and Boyle’s law.
3 · Actuators Single-acting, double-acting and balanced jacks, differential area , hydraulic lock .
4 · Pressure control Relief valves, priority (pressure maintaining) and reducing valves.
5 · Flow control Check, restrictor, shuttle , sequence and flow control valves, modulators, fuses .
6 · The whole aircraft Indications, servicing parts, multiple systems, PTU, RAT , HP pneumatics.
Chapter 4 · Hydraulic Pumps, Valves and Actuators
2
e-books by eatpl.in · © 2026 · Do not copy or distribute
This lesson opens up the working parts of a hydraulic system. We start with the pumps: the simple hand pump, the constant-delivery gear pump and the constant-pressure swash-plate pump that most modern aircraft use. Then the automatic cut-out valve, and the accumulator that works with it, including the gas pre-charge and Boyle’s law sums that the exam loves. Third, the actuators themselves, the different types of jack, the effect of the piston rod, and hydraulic lock. Fourth, the valves that control pressure: relief, priority and reducing valves. Fifth, the valves that control flow: check valves, restrictors, shuttle valves, sequence valves, modulators and hydraulic fuses. Finally we step back to the whole aircraft: the cockpit indications, the parts fitted for servicing, how airliners combine several independent systems with a power transfer unit and a ram air turbine, and the high-pressure pneumatic systems that a few aircraft use instead.
Part 1 · Pumps
Six ways to drive a hydraulic pump A pump draws fluid from the reservoir and delivers a flow into the system. The ATM, RAT and PTU usually give an alternate supply for redundancy.
Hand Light aircraft, ground servicing, testing lines, cargo doors without power.
Engine-driven (EDP) The main source on most aircraft: driven from the engine accessory gearbox.
Electric motor Standby or auxiliary pumps (AC or DC motor); also the main pump in some light systems.
Air turbine motor (ATM) A small turbine driven by bleed air turns the pump.
Ram air turbine (RAT) A propeller lowered into the airstream drives an emergency pump.
Power transfer unit (PTU) A hydraulic motor in one system drives a pump in another: power moves, fluid does not.
Chapter 4 · Hydraulic Pumps, Valves and Actuators
3
e-books by eatpl.in · © 2026 · Do not copy or distribute
A pump has one job: to draw fluid from the reservoir and deliver a flow into the system. What turns it can vary. The hand pump is the simplest. On most aircraft the main source is the engine-driven pump, turned by the engine’s accessory gearbox. Electric motor pumps are common as standby or auxiliary pumps, and in some light aircraft they are the main pump. An air turbine motor uses bleed air to spin a small turbine that drives the pump. The ram air turbine is a small propeller lowered into the airstream in an emergency, driving its own pump. And the power transfer unit is a hydraulic motor in one system mechanically coupled to a pump in another, so one system can lend power to the other without any fluid crossing between them. The air turbine, the ram air turbine and the power transfer unit are usually there for redundancy, as alternate supplies.
Part 1 · Pumps
The hand pump Usually double acting : it delivers fluid on both the in and the out strokes Built-in non-return valves on the inlet and outlet of each chamber A relief valve , typically set about 10% above normal system pressure May be the only power source in a small, light system On large aircraft it is fitted mainly for ground servicing without engines running, pressure testing lines and joints, and operating cargo doors without power Delivers on both strokes in stroke from reservoir to system delivering filling relief valve ≈ 10% above On the out stroke the roles swap: the right side delivers, the left side fills
Chapter 4 · Hydraulic Pumps, Valves and Actuators
4
e-books by eatpl.in · © 2026 · Do not copy or distribute
The hand pump is usually double acting, which means it delivers fluid on both strokes of the handle. Look at the drawing. As the handle pushes the piston one way, the chamber ahead of it is squeezed, and fluid leaves through its outlet non-return valve to the system, while the chamber behind it fills through its inlet non-return valve from the reservoir. On the return stroke the two chambers swap roles, so there is a delivery on every stroke. A relief valve, typically set about ten per cent above normal system pressure, stops the operator over-pressurising anything. In a small, light aircraft the hand pump may be the only source of hydraulic power. On large aircraft it is mostly a servicing tool: it lets engineers operate services on the ground without running the engines, pressure test lines and joints, and open cargo doors when no power is available. It draws from the bottom of the reservoir, below the stack pipe.
Part 1 · Pumps
Constant-delivery (fixed-volume) pumps Usually a single- or double-stage gear pump : a fixed volume per revolution So its output is proportional to RPM , whatever the system needs; a large flow at low pressure It needs an automatic cut-out valve (or relief valve) to send the flow back to the reservoir when the jacks stop With no service working it needs an idling circuit , still giving a cooling and lubricating flow Like every high-pressure pump it needs a positive fluid supply at its inlet suction (inlet) delivery (outlet) fluid carried round the outside of each gear Fixed volume per turn: output ∝ RPM
Chapter 4 · Hydraulic Pumps, Valves and Actuators
5
e-books by eatpl.in · © 2026 · Do not copy or distribute
The constant-delivery, or fixed-volume, pump is usually a gear pump. Two meshing gears turn in a close-fitting casing. Fluid from the reservoir is trapped in the spaces between the teeth, carried round the outside of each gear and squeezed out on the delivery side where the teeth come together. Every revolution moves the same volume, so the delivery depends only on how fast the pump turns. Watch the flow gauge: if the engine speed doubles, the delivery doubles too. The pump has no idea whether the system needs that fluid, so once the jacks reach the end of their travel, something must take the flow away, otherwise the pressure would climb until something burst. That is the job of the automatic cut-out valve, or a relief valve, which returns the flow to the reservoir through an idling circuit. Even then, fluid keeps passing through the pump to cool and lubricate it.
Part 1 · Pumps
Constant-pressure (variable-volume) pumps An axial multi-piston pump: the cylinder block turns with the drive shaft; piston shoes run on a stationary, tilting yoke (swash plate) Yoke angle sets the piston stroke , and so the delivery; it controls its own pressure (typically 3000–4000 psi ) Low pressure : the spring holds the yoke at maximum angle → full stroke. So at start-up, and after shutdown, it sits at maximum stroke Pressure reached : the control piston turns the yoke to minimum stroke , keeping a small flow for lubrication, leakage and coolingA solenoid off-load (depressurising) valve can block delivery: output falls to about 50–200 psi ; a case drain carries the internal leakage Low pressure (start-up, service selected) spring wins: yoke at maximum angle → full stroke, maximum delivery drive yoke control piston spring System pressure reached control piston: yoke near upright → minimum stroke, small cooling flow drive yoke control piston spring
Chapter 4 · Hydraulic Pumps, Valves and Actuators
6
e-books by eatpl.in · © 2026 · Do not copy or distribute
Most modern aircraft use the constant-pressure, or variable-volume, pump. It is an axial piston pump: a ring of pistons sits in a cylinder block that turns with the drive shaft, and the piston shoes slide on a yoke, or swash plate, that does not rotate but can tilt. The steeper the yoke, the further each piston moves per revolution, so the more fluid the pump delivers. When system pressure is low, for example just after a service is selected, a spring holds the yoke at its maximum angle and the pump gives full output. As the jacks stop and pressure builds, a control piston, fed with system pressure, pushes the yoke back towards upright until the stroke is just big enough to cover leakage and keep a cooling flow. So at shutdown the spring moves the yoke to maximum stroke, ready for the next start. A solenoid off-load valve can also drop output to fifty to two hundred psi.
Part 1 · Pumps
How each pump responds to system pressure 0 500 1000 1500 2000 2500 3000 0% 25% 50% 75% 100% System pressure (psi) Pump delivery (% of maximum) constant-delivery pump: same flow at all pressures constant-pressure pump minimum stroke: cooling flow only What the graph shows • Variable pump: full delivery until pressure nears its setting, then it throttles back by itself • Fixed pump: same flow regardless; an ACOV or relief valve must dump it at 3000 psi • Both need a positive inlet supply (pressurised reservoir) to avoid cavitation A high-pressure pump must have a positive fluid supply : it cannot suck fluid up reliably, and a starved inlet cavitates. Neither pump may run dry.
Chapter 4 · Hydraulic Pumps, Valves and Actuators
7
e-books by eatpl.in · © 2026 · Do not copy or distribute
This graph compares the two kinds of pump. The blue dashed line is the constant-delivery pump: it delivers the same flow at every pressure, because its output depends only on its speed. So when the system reaches three thousand psi, an automatic cut-out valve or a relief valve must take that flow away and return it to the reservoir. The red line is the constant-pressure pump. It gives full delivery while the pressure is low, but as the pressure approaches its setting, about two thousand eight hundred and fifty psi in this example, the control piston starts to reduce the yoke angle, and by three thousand psi the delivery has fallen to a small cooling flow. It throttles itself back, so it needs no cut-out valve. One rule applies to both pumps: a high-pressure pump must be given a positive supply of fluid at its inlet. It cannot suck reliably, and if it is starved it cavitates and is damaged, which is why reservoirs are pressurised.
Part 2 · Cut-out valves
The automatic cut-out valve (ACOV) Fitted with a constant-delivery (fixed-volume) pump : controls system pressure and gives an idling circuit when no service is selected Cut in : pump delivery passes the NRV to the system. At full pressure the piston lifts, opens the poppet: cut out , pump flow returns to the reservoir at low pressureAn accumulator is always fitted: with the NRV it holds system pressure while cut out, so small leaks do not make the pump cycle constantly The time between cut-out and cut-in shows system health: external leaks → fast cycling and fluid loss; internal leaks → fast cycling and hotter fluid If the ACOV sticks cut in , pressure rises until the full-flow relief valve opens CUT IN (on load) pump NRV → system poppet closed: flow to system CUT OUT (off load) pump NRV → system poppet open: flow to tank Accumulator + NRV hold the pressure while the pump idles Fast cycling = leaks (external: fluid lost; internal: fluid hot) or low pre-charge
Chapter 4 · Hydraulic Pumps, Valves and Actuators
8
e-books by eatpl.in · © 2026 · Do not copy or distribute
A fixed-volume pump needs an automatic cut-out valve. Watch the model. The pump delivers through the non-return valve, and the accumulator charges until system pressure reaches three thousand psi. Now the valve unloads: system pressure under its piston lifts it, opening a poppet valve, and the pump’s flow goes straight back to the reservoir at low pressure. The pump is idling, but still cooled and lubricated. Meanwhile the non-return valve and the accumulator hold the system at full pressure. When a service draws fluid, the pressure falls; the piston drops, the poppet closes and the pump is back on load, recharging the system. This is why an accumulator is always fitted with an ACOV: without it, the tiniest leak would make the valve cut in and out continually. The time between cut-out and cut-in is a health check. External leaks make it cycle quickly and lose fluid; internal leaks make it cycle quickly and heat the fluid. If the valve sticks cut in, the full-flow relief valve protects the system.
Part 2 · Accumulators
What an accumulator does Stores fluid under pressure : its main job; a gas charge (nitrogen or air) is squeezed by the incoming fluidDamps pressure fluctuations (surges, “hammering”) and allows for thermal expansion Gives an emergency supply if the pump fails, and the initial fluid when a selection is made with the pump cut out Prolongs the period between cut-out and cut-in of the ACOV, reducing pump wearTypes: free piston , diaphragm , bladder ; a separator isolates gas from fluid; an NRV upstream stops it discharging to the reservoir piston diaphragm bladder nitrogen (or air) above · fluid below Gas charging valve on top · fluid port at the bottom A non-return valve upstream stops it discharging back to the tank
Chapter 4 · Hydraulic Pumps, Valves and Actuators
9
e-books by eatpl.in · © 2026 · Do not copy or distribute
An accumulator is a pressure vessel with gas on one side and hydraulic fluid on the other, kept apart by a free piston, a diaphragm or a rubber bladder. That separator stops the gas dissolving into the fluid. The gas side is charged with nitrogen, or sometimes air, through a charging valve on top, and the fluid enters at the bottom. What does it do? Its main purpose is to store fluid under pressure. Because the gas acts like a spring, it also damps out pressure surges and hammering, and gives room for the fluid to expand as it warms. If the pumps fail it provides an emergency supply, and when a service is selected while the pump is cut out, it provides the first rush of fluid. With an automatic cut-out valve, it lengthens the time between cut-out and cut-in, which saves pump wear. A non-return valve upstream stops it discharging backwards into the reservoir. It does not replace the reservoir, and it does not absorb landing loads.
Part 2 · Accumulators
Pre-charge and the accumulator gauge The gas side is pre-charged (e.g. 1000 psi) with no fluid in it; pre-charge is above the pressure any service needs As the pump runs, fluid enters and squeezes the gas until gas pressure = fluid pressure So with the system at 3000 psi , the accumulator gauge reads 3000 psi , not the pre-charge; the system gauge also reads 3000 Boyle’s law: 1000 psi → 3000 psi means the gas is squeezed to ⅓ of its volume: ⅔ fluid The gauge shows the pre-charge only when the system is depressurised and the accumulator empty of fluid 1000 psi pre-charge gas volume V 3000 psi pump at 3000 gas V/3 2000 psi after use gas V/2 Gas pressure = fluid pressure once fluid is in: P₁V₁ = P₂V₂
Chapter 4 · Hydraulic Pumps, Valves and Actuators
10
e-books by eatpl.in · © 2026 · Do not copy or distribute
Here is the exam’s favourite accumulator question. With the system depressurised and no fluid inside, the free piston sits at the bottom and the gauge on the gas side shows the nitrogen pre-charge, say one thousand psi. Now the pump runs. Fluid flows in, pushes the floating piston up and squeezes the gas. The gas pressure rises until it equals the fluid pressure, because the piston can only stop when the forces on both sides balance. With the system at three thousand psi, the accumulator gauge therefore reads three thousand psi, not one thousand. Boyle’s law tells us the volume: three times the pressure means one third of the volume, so the accumulator is two thirds full of fluid. When a service uses fluid, the gas expands and the pressure falls, here to two thousand psi with the gas at half its original volume. The gauge only ever shows the pre-charge when the system pressure has been released.
Part 2 · Accumulators
Boyle’s law: how much fluid an accumulator holds 0 10 20 30 40 50 60 70 80 0 1000 2000 3000 4000 Fluid in the accumulator (% of its volume) Gas (and system) pressure, psi system pressure 3000 psi pre-charge 1000 psi pre-charge 1500 psi ⅔ full half full Worked example (Boyle: P₁V₁ = P₂V₂) Accumulator 6 litres, pre-charge 1000 psi. At 3000 psi: gas = 6 × 1000 ÷ 3000 = 2 L so fluid stored = 4 L (⅔ full) At 2000 psi: gas = 6 × 1000 ÷ 2000 = 3 L so fluid left = 3 L Fluid delivered from 3000 down to 2000 psi: 1 L (⅙ of the volume)Pre-charge 1500 psi: half full at 3000 psi The gauge reads 3000 in every case Gas pressure × gas volume stays constant (at constant temperature). The accumulator gauge always shows the gas pressure , which equals the fluid pressure once fluid has entered.
Chapter 4 · Hydraulic Pumps, Valves and Actuators
11
e-books by eatpl.in · © 2026 · Do not copy or distribute
Boyle’s law tells us how much fluid an accumulator can store. At constant temperature, pressure times volume stays the same for the gas. Take a six litre accumulator pre-charged to one thousand psi. When the system reaches three thousand psi, the gas is squeezed to six times one thousand divided by three thousand, which is two litres, so four litres of fluid are stored: the accumulator is two thirds full. If a service draws the pressure down to two thousand psi, the gas has expanded to three litres, so one litre of fluid has been delivered. On the graph, the red curve is the one thousand psi pre-charge and the purple dashed curve is fifteen hundred psi; with the higher pre-charge, the accumulator is only half full at three thousand psi. Notice that in every case, once there is fluid inside, the gauge reads the same as the system, three thousand psi.
Part 2 · Accumulators
Checking the pre-charge, and what goes wrong Charged through a charging valve (a non-return valve) on the accumulator or a remote ground panel Check or set the pre-charge only with the system pressure released , so the piston is at the bottom No gauge? Stop the pump and operate services: pressure falls steadily, then drops suddenly to zero ; the reading just before is the pre-charge Low pre-charge → frequent cut-in/cut-out, rapid pressure fluctuations , chattering and hammering , which is harmfulThe flight-deck system pressure gauge reads fluid pressure ; brake accumulators guarantee a set number of applications 0 20 40 60 80 0 1000 2000 3000 Fluid used, pump stopped (% of volume) Pressure (psi) last reading before the sudden drop = pre-charge Low pre-charge → rapid ACOV cycling, pressure fluctuations, chattering and “hammering” Hammering also comes from trapped air: it can fracture pipes
Chapter 4 · Hydraulic Pumps, Valves and Actuators
12
e-books by eatpl.in · © 2026 · Do not copy or distribute
The gas side is charged through a charging valve, really a non-return valve whose plunger can be pressed to let gas out. It may be on the accumulator or on a remote ground servicing panel. To check or set the pre-charge, first release the system pressure, so the fluid leaves and the gas pushes the piston to the bottom; only then does the gauge show the true pre-charge. If there is no gauge, there is a neat trick. Stop the pump and keep operating services. The pressure falls steadily as the accumulator empties, then, when the piston bottoms, it suddenly drops to zero. The last reading before that sudden drop is the pre-charge. A low or incorrect pre-charge makes the cut-out valve cycle too often, so the pressure fluctuates rapidly and you hear chattering and hammering. Hammering is never normal: trapped air causes it too, and left alone it can fracture pipes. Remember that the system pressure gauge always shows fluid pressure.
Part 3 · Actuators
Jacks (actuators): three types A jack turns fluid flow into linear movement: a piston and seals in a cylinder, a rod (ram) through a gland seal Single acting : pressure one way, spring the other; used as a lock (spring-engaged, hydraulically released), e.g. the gear up-lock Double acting unbalanced : the rod reduces the area on one side, so more force on extension ; the heavier task is done by extending, e.g. raising the gear Double acting balanced : rod through both ends, equal force both ways : nosewheel steering, flying control boostA balanced jack does not change the reservoir level as it moves (no ram displacement) Single acting spring return · e.g. gear up-lock Unbalanced most aircraft jacks full area annulus = area − rod Balanced steering, flying control boost equal areas · equal force both ways Unbalanced: put the heavier job (e.g. gear retraction) on the extend stroke, where the full piston area acts
Chapter 4 · Hydraulic Pumps, Valves and Actuators
13
e-books by eatpl.in · © 2026 · Do not copy or distribute
A jack, or actuator, converts fluid flow into straight-line movement. It is a piston with seals sliding in a cylinder, with a rod, or ram, passing out through a gland seal at one end. There are three types. The single-acting jack has pressure on one side only and a spring on the other. It is typically used as a lock, engaged by the spring and released by hydraulic pressure, such as a landing gear up-lock. The double-acting unbalanced jack is the most common. Because the rod takes up part of one face, the full piston area on the other side is bigger, so the jack pushes harder when it extends. The designer therefore arranges the heaviest job, such as raising the landing gear, on the extension stroke. The balanced jack has a rod coming out of both ends, so the areas, and the forces, are equal both ways. That suits nosewheel steering and flying control boost, and it does not change the reservoir level.
Part 3 · Actuators
Differential area: why the rod side is weaker The rod side of the piston has less area by exactly the rod’s cross-section Same pressure, larger area → the cap side force is greater Example: piston 10 in², rod 4 in²: at 3000 psi, 30 000 lbf to extend but only 18 000 lbf to retract If both sides get the same pressure, the jack extends with a net force = pressure × rod area For the same flow, the rod side also moves faster (smaller volume to fill) same 3000 psi to both ports 30 000 lbf 18 000 lbf rod extends Piston 10 in² · rod 4 in² · annulus 6 in² Net force = 3000 × (10 − 6) = 3000 × 4 = 12 000 lbf
Chapter 4 · Hydraulic Pumps, Valves and Actuators
14
e-books by eatpl.in · © 2026 · Do not copy or distribute
Let us put numbers on the unbalanced jack. The rod covers part of one face of the piston, so the rod side, the annulus, has less area than the cap side by exactly the area of the rod. Say the piston is ten square inches and the rod four. At three thousand psi, the full piston area pushes with thirty thousand pounds force, but on the annulus side only six square inches are left, giving eighteen thousand pounds. Now a favourite exam question: what happens if the same pressure is applied to both sides of the jack at once? Pascal says the pressure is equal, but the areas are not, so the cap side wins and the jack extends. The net force is the pressure times the rod area, twelve thousand pounds force here. As it extends, fluid from the rod side simply joins the flow into the cap side. Remember too that, for the same flow, a jack retracts faster than it extends.
Part 3 · Actuators
Hydraulic lock Fluid trapped between a jack’s piston and a closed valve (a non-return valve , or the selector in neutral ) The fluid cannot flow and cannot be compressed, so the piston cannot move , even under load There is no flow and the jack is stationary ; under a load, the trapped pressure rises Useful: it holds services in position (e.g. flaps, steering damping) with the selector in neutral Trapped lines need thermal relief valves , because heating the fluid raises the pressure selector NEUTRAL: both lines blocked load rises no movement: oil is incompressible Also formed between a jack and a non-return valve Thermal relief valves protect such trapped lines from heat
Chapter 4 · Hydraulic Pumps, Valves and Actuators
15
e-books by eatpl.in · © 2026 · Do not copy or distribute
A hydraulic lock forms when fluid is trapped between the piston of a jack and a closed valve, typically a non-return valve, or a selector in its neutral position. Watch the model. The selector is in neutral, so both jack lines are blocked and the fluid is trapped on both sides of the piston. Now an external load pushes on the rod. The oil cannot escape and it cannot be compressed, so the piston does not move at all; instead, the gauge shows the trapped pressure rises to resist the load. So in a hydraulic lock there is no flow and the jack stays still. Designers use this deliberately: with the selector in neutral, a service such as the flaps is held exactly where it is. The catch is temperature. If the trapped fluid warms up, it tries to expand and its pressure can climb dangerously, which is why lines that can be isolated are fitted with thermal relief valves.
Part 4 · Pressure control
Relief valves All are safety devices that relieve excess pressure back to the reservoir; each relieves at its designed pressure Full-flow (high-pressure) relief valve : downstream of the pump , between pump and reservoir; passes the whole pump output if the ACOV or pump control fails or a line is blockedIt cracks just above system pressure and is fully open at about 10% above (e.g. opens ≈ 3100–3200, full flow 3300 psi) Thermal relief valves : in lines isolated by NRVs or selectors; relieve the pressure rise from thermal expansion ; set ≈ 10% above system pressureFlap relief valve : mechanical overload protection: lets flaps blow back towards UP if lowered at too high an airspeedadjuster system pressure to reservoir spring sets the opening pressure Full-flow relief, 3000 psi system shut at 3000 psi cracks just above (≈ 3100–3200) fully open ≈ 3300 psi (+10%) passes the whole pump flow Thermal relief: isolated lines · Full-flow: after the pump · Flap relief: blow-back
Chapter 4 · Hydraulic Pumps, Valves and Actuators
16
e-books by eatpl.in · © 2026 · Do not copy or distribute
In the simplest relief valve, a spring holds a ball on its seat. When the pressure under the ball exceeds the spring setting, the ball lifts and fluid escapes to the reservoir. Each valve relieves at its own designed pressure. There are three uses. The full-flow, or high-pressure, relief valve sits downstream of the pump, between the pump and the reservoir. It must be able to pass the whole pump output if the automatic cut-out valve or the pump’s own control fails, or if a line is blocked. It cracks open just above normal system pressure and is fully open at about ten per cent above, so with a three thousand psi system, full flow at about thirty three hundred. Thermal relief valves sit in lines that can be isolated by non-return valves or selectors, and bleed off the pressure rise caused by thermal expansion. And a flap relief valve lets the flaps blow back towards up if they are lowered at too high a speed.
Part 4 · Pressure control
Priority and pressure-reducing valves Pressure-maintaining (priority) valve : basically a relief valve that keeps pressure in a primary service regardless of secondary demandsIt shuts off lower-priority services when supply pressure falls (e.g. after a leak or pump loss), so essential services such as flying controls keep working Pressure-reducing valve : lowers main system pressure to suit a service, e.g. the wheel brakes Brake control valve : a variable pressure-reducing valve set by the pedals, anti-skid and autobrakeMain system pressure itself is set by the pump (and ACOV); the relief valves only back it up supply 3000 psi essential: flying controls priority valve secondary shuts off secondary services when supply pressure falls pressure reducing brakes 3000 psi lower Brake control valve = a variable pressure-reducing valve (pedals, anti-skid, autobrake)
Chapter 4 · Hydraulic Pumps, Valves and Actuators
17
e-books by eatpl.in · © 2026 · Do not copy or distribute
Some valves control pressure without being safety devices. The pressure-maintaining valve, also called a priority valve, is really a relief valve used for a different purpose. It sits in the supply to the secondary, less important, services. As long as system pressure is healthy, it stays open and everything works. If the pressure falls, for example after a leak or the loss of a pump, the valve closes and shuts off the secondary services, so whatever pressure remains is kept for the primary ones, such as the flying controls. That is why it is described as maintaining pressure for essential services even if lower-priority services cannot operate. The pressure-reducing valve does something else: it lowers the full system pressure to a value that suits a particular service, typically the wheel brakes. The brake control valve is a variable version of it, giving a brake pressure that follows the pilot’s pedals, the anti-skid system and the autobrake.
Part 5 · Flow control
Non-return valves and restrictors Non-return valve (one-way check valve): full flow one way , none the other, like a diode; an arrow on the casing prevents wrong fittingIt closes when inlet pressure falls below outlet pressure (or ceases), and opens when inlet exceeds outlet Restrictor (choke) : limits the rate of movement of a service; a one-way restrictor gives restricted flow one way, full flow the otherIn the gear UP line it meters fluid leaving the jack as the gear falls, so gear extension is not too fast ; it is also used to slow flap retraction Neither valve changes the system pressure; they control direction and rate of flow Non-return (check) valve arrow on casing: flow direction in out opens when inlet > outlet; closes when inlet pressure falls below outlet One-way restrictor (choke) orifice free flow → lifts the piston · ← restricted: only through the orifice Fitted in the gear UP line (limits free-fall extension) and to slow flap retraction
Chapter 4 · Hydraulic Pumps, Valves and Actuators
18
e-books by eatpl.in · © 2026 · Do not copy or distribute
The non-return valve, also called a one-way check valve, lets fluid flow freely in one direction and blocks it in the other, rather like a diode in an electrical circuit. A light spring holds a ball or poppet on its seat. When the inlet pressure exceeds the outlet pressure, it lifts; when inlet pressure falls below outlet pressure, or stops altogether, it closes. An arrow on the casing shows which way to fit it. The restrictor, or choke, limits the rate at which a service moves. A one-way restrictor has a small orifice drilled through its poppet: flow one way lifts the poppet and passes freely, flow the other way seats it and must squeeze through the orifice. A classic use is in the landing gear up line. When the gear is lowered, its weight wants to make it fall quickly, and the restrictor meters the fluid leaving the up side, so the extension is controlled. It is also used to slow flap retraction.
Part 5 · Flow control
The shuttle valve Lets two separate supplies operate one service : e.g. normal and alternate brakes, or gear extension by an emergency air (nitrogen) bottle Normally the normal supply flows freely and the alternate line is blocked When normal pressure is lost and the alternate is selected, the pressure difference slides the shuttle across: normal line blocked, alternate connected It moves automatically, but only once the alternate supply is pressurised (selected) Stuck in the normal position: alternate (emergency) operation is impossible Normal operation normal alternate Normal lost, alternate selected normal alternate If it sticks in the NORMAL position, the alternate supply cannot get through
Chapter 4 · Hydraulic Pumps, Valves and Actuators
19
e-books by eatpl.in · © 2026 · Do not copy or distribute
The shuttle valve lets two separate supplies operate the same service. You find it in brake and landing gear systems, including where an emergency air bottle can lower the gear. Look at the body: there is a normal inlet on one side, an alternate inlet on the other, and an outlet to the service between them. In normal operation, normal system pressure holds the shuttle hard against the alternate inlet, so fluid flows from the normal system to the brakes. Now suppose the normal supply fails. The brakes lose pressure. The pilot selects the alternate system, and its pressure, now higher than the dead normal line, pushes the shuttle across to the other end. The normal line is blocked, so alternate fluid cannot escape into the failed system, and the brakes work again. So the shuttle moves by itself, but only once the alternate supply is pressurised. And if the shuttle sticks in the normal position, the alternate supply can never reach the service.
Part 5 · Flow control
Selectors, sequence valves, modulators and flow control Selector : directs fluid to one side of a jack and returns the other side; may be electrically operated (motor or solenoid) when it is far from the cockpitSequence valve : makes sure one operation is complete before the next starts , e.g. gear doors open before the gear movesModulator : with anti-skid brakes, gives full flow on the first application, then a restricted flowFlow control valve : keeps a constant flow to a component, typically upstream of a hydraulic motor that must run at constant speedHydraulic motor : a rotary actuator built like a piston pump; its speed depends on the flow into itselector 1 · door jack opens the doors sequence pushed open at end of door travel 2 · then the gear jack moves flow control motor: constant speed
Chapter 4 · Hydraulic Pumps, Valves and Actuators
20
e-books by eatpl.in · © 2026 · Do not copy or distribute
Several valves organise when and how fast things happen. The selector, as we know, directs fluid to one side of a jack and returns the other side; when it has to sit far from the cockpit, it is moved electrically by a motor or solenoids instead of long linkages. The sequence valve makes sure one operation is finished before the next begins. In a landing gear, the selector first sends pressure to the door jacks. Only when the doors are fully open does the door jack physically push open the sequence valve, which then lets pressure through to the gear jack, so the gear never swings into a closed door. A modulator works with anti-skid brakes, giving full flow when the brakes are first applied and then a restricted flow. A flow control valve keeps a constant flow to a component, typically a hydraulic motor that must turn at a constant speed, because a hydraulic motor’s speed depends on the flow fed into it.
Part 5 · Flow control
Hydraulic fuses Purpose: if a line bursts, the fuse blocks it and so minimises fluid loss , keeping the rest of the system working Type 1 : shuts off when the pressure drop across it (i.e. the flow rate ) is too highType 2 : shuts off after a given volume has passed; normal operation never uses enough to close itFitted upstream of services that could leak (in their supply), typically the non-essential branches, so a leak there cannot drain the essential services Wheel brakes are invariably protected by fuses (exposed wheel-well pipes); a fuse does not “rupture”: it closesNormal flow: piston drifts a little, fluid passes supply to brakes Pipe burst downstream: piston slams shut supply to brakes Type 1: shuts when the pressure drop (flow rate) is too high Type 2: shuts after a set volume has passed
Chapter 4 · Hydraulic Pumps, Valves and Actuators
21
e-books by eatpl.in · © 2026 · Do not copy or distribute
A single burst pipe must not drain a whole system, and the hydraulic fuse prevents that. It sits in the supply line to a service, upstream of it, and if that service’s pipe bursts, the fuse closes and blocks the line, minimising the loss of fluid so that everything else carries on working. There are two kinds. The first senses the pressure drop across it, which means the flow rate: a burst pipe makes a much higher flow, the pressure drop pushes the piston across against its spring, and the line is sealed. The second does not care about the rate; it counts the volume, closing after a set quantity has passed. Normal operation never needs enough to close it, but a leak does. Fuses are fitted in branches where a leak is likely, typically the non-essential services, so a leak there cannot starve the essential ones, and wheel brakes, with their exposed pipes in the wheel wells, are always protected by fuses.
Part 6 · The whole aircraft
Indications on the flight deck Quantity : a sight glass for servicing; a float-type transmitter for the flight-deck gaugePressure : a pressure relay feeds a direct gauge or a transmitter; the system gauge shows fluid pressure ; direct gauges sit at accumulators and reservoirsPressure switches light warnings for low fluid pressure or low reservoir air pressure Temperature : overheat sensing in the reservoir, and in the casing of electric emergency pump motorsFlow indicator in a constant-delivery pump outlet warns of pump failure . Light aircraft: often just a pump-running light plus gear and flap indicatorsGREEN 3000 psi ENG 1 QTY BLUE 3000 psi ELEC RAT QTY YELLOW 3000 psi ENG 2 ELEC QTY Quantity: sight glass; float transmitter in the reservoirPressure: relay → gauge or transmitter; direct gauges at accumulatorsPressure switch: LO PRESS lamp (fluid, or reservoir air)Temperature: reservoir sensor; emergency pump motor casingFlow indicator: warns of constant-delivery pump failure
Chapter 4 · Hydraulic Pumps, Valves and Actuators
22
e-books by eatpl.in · © 2026 · Do not copy or distribute
The crew need to know what the hydraulic systems are doing. Light aircraft may have little more than a light showing the electric pump is running, plus the gear and flap indicators. Larger aircraft show quantity, pressure and temperature, and many show the whole system on an electronic display like this stylised three-system page. Quantity comes from a float-type transmitter in the reservoir; the engineers also have a sight glass. Pressure is picked up by a pressure relay, which feeds either a direct-reading gauge or a transmitter for the flight-deck instrument. Remember that the system pressure gauge shows fluid pressure; direct-reading gauges are also fitted on accumulators and reservoirs for servicing. Pressure switches light warning lamps when fluid pressure is low, or when the reservoir’s air pressure is lost. Overheating is detected by a temperature sensor in the reservoir, and in the casing of electric motors that drive emergency pumps. And a flow indicator in the outlet of a constant-delivery pump warns that the pump has failed.
Part 6 · The whole aircraft
Components fitted for servicing Usually grouped in the hydraulic equipment bay , these make maintenance quick, clean and safe:
Quick-disconnect couplings Self-sealing : a line can be split with no fluid loss and no need to bleed afterwards.
Ground service couplings Let a ground rig pressurise and test the system without running the engines .
Pressure release (off-load) valves Manually release system pressure before checking pre-charge or reservoir level .
Drain cocks Simple manual valves at the lowest point so the system can be drained.
Firewall shut-off valves At the engine bulkhead: stop fluid to the engine-driven pumps for an engine fire (fire handle) or a pump change.
Fluid sampling points In the suction and pressure lines, to take samples for analysis (contamination, water, wear metal).
Chapter 4 · Hydraulic Pumps, Valves and Actuators
23
e-books by eatpl.in · © 2026 · Do not copy or distribute
A number of components are there purely to make servicing easier, and most live in the hydraulic equipment bay. Self-sealing quick-disconnect couplings let a line be split without losing fluid and without having to bleed the system afterwards. Ground service couplings let a ground hydraulic rig pressurise the system, so it can be tested and operated without running the engines. Pressure release, or off-load, valves are opened by hand to release system pressure before the engineer checks accumulator pre-charges or reservoir levels. Drain cocks are simple manual valves at the lowest point, so the system can be drained. Shut-off valves at the engine firewall can stop the fluid supply to the engine-driven pumps; they close when the fire handle is pulled, or for a pump change, and they are usually ball valves that give unrestricted flow when open. Finally, fluid sampling points in the suction and pressure lines let samples be taken for laboratory analysis.
Part 6 · The whole aircraft
Multiple independent systems, linked by a PTU GREEN reservoir EDP (engine 1) BLUE reservoir electric pump RAT (emergency) YELLOW reservoir EDP (engine 2) electric pump hand pump PTU: hydraulic motor ⇄ pump, green ↔ yellow power transferred, fluid never mixed Flight controls: each surface fed by two or three systems via priority valves; any one system can fly the aircraft gear, normal brakes alternate brakes, cargo doors Typical Airbus layout (3000 psi): green , blue , yellow . Boeing names them A, B and standby, or 1 to 4. The flying controls get a priority-valved sub-system , sometimes with its own accumulator.
Chapter 4 · Hydraulic Pumps, Valves and Actuators
24
e-books by eatpl.in · © 2026 · Do not copy or distribute
A transport aircraft cannot depend on one hydraulic system, so it has two, three or even four independent ones, each with its own reservoir, pumps and pipes, and the primary flying controls are fed by more than one at the same time. This picture shows a typical Airbus layout. The green system has an engine-driven pump on engine one. The yellow system has an engine-driven pump on engine two, an electric pump and a hand pump for the cargo doors. The blue system has an electric pump and, in an emergency, the ram air turbine. Between green and yellow sits the power transfer unit: a hydraulic motor driven by one system, mechanically coupled to a pump in the other, so either system can drive the other if it loses its engine pump, without any fluid passing between them. The flight controls are fed through priority valves, so they keep their pressure even when other services are starved, and any one system on its own can still fly the aircraft.
Part 6 · The whole aircraft
The ram air turbine (RAT) A small variable-pitch propeller on a strut, driving a hydraulic pump (and on many types a generator) through a gearbox Deploys automatically when main power is lost (e.g. both engines, or all AC), or manually; stowed with the blades feathered A governor holds a constant speed by changing blade pitch as airspeed varies Gives limited power to essential services : the primary flying controls ; on some types also flaps/slats and spoilers It does not power the landing gear: the gear is lowered by gravity (free fall) or an alternate system lower fuselage airflow pump to flying controls deploys by gravity + spring Stowed with the blades feathered; usually cannot be re-stowed in flight
Chapter 4 · Hydraulic Pumps, Valves and Actuators
25
e-books by eatpl.in · © 2026 · Do not copy or distribute
The ram air turbine is the last line of defence. It is a small propeller on a strut, stowed in a bay in the fuselage or wing root, with its blades feathered. If the aircraft loses its main power, for example both engines, or all its AC electrical power, it drops out into the airstream automatically; the crew can also deploy it by hand. The blades unfeather to a working pitch, and the airflow spins the turbine, which drives a hydraulic pump through a gearbox, and on many aircraft a small generator too. A governor varies the blade pitch to keep the speed constant as the airspeed changes. Its power is limited, so it goes to the essential services: the primary flying controls first, and on some types the slats or flaps and some spoilers. It does not raise or lower the landing gear; the gear comes down by gravity or an alternate system. Once deployed, a RAT usually cannot be re-stowed in flight.
Part 6 · The whole aircraft
High-pressure pneumatic systems A few aircraft (e.g. the F27 ) use compressed air instead of hydraulics for gear, brakes and doors Advantages: air is free and everywhere, lighter , no fire hazard , no viscosity change with temperature, no return lines Main disadvantage: air is compressible ; so modern transports use hydraulics for big loads F27: engine-driven 4-stage compressor , unloading valve holds 3300 psi ; moisture separator (98% of water), dryer (silica gel), 10-micron filter Three bottles (750, 180, 180 in³); a reducing valve gives ≈ 1000 psi to the services; a shuttle valve allows charging from an external source 4-stage compressor moisture separator 98% dryer silica gel filter 10 micron shuttle ground charge main 750 in³ brakes 180 in³ emergency 180 in³ 3300 psi reducing valve ≈ 1000 psi to: gear, door, nose steering, prop brake For: air is free, light, no fire risk, no viscosity change, no return lines Against: air is compressible (spongy); water must be removed (freezing)
Chapter 4 · Hydraulic Pumps, Valves and Actuators
26
e-books by eatpl.in · © 2026 · Do not copy or distribute
A few aircraft, such as the Fokker F twenty seven, use high-pressure compressed air instead of hydraulics. Air is free, lighter than fluid, no fire hazard, has no viscosity problems in the cold, and needs no return lines, because used air is simply vented. Its big drawback is compressibility, which makes it spongy. In the F twenty seven, a four-stage compressor on each engine’s accessory gearbox charges the system, and an unloading valve holds it at thirty three hundred psi. A moisture separator removes ninety eight per cent of the water, a silica gel dryer removes the rest, and a ten micron filter cleans the air. Three bottles store the air: seven hundred and fifty cubic inches for the main system and a hundred and eighty each for brakes and emergency. A reducing valve supplies about a thousand psi to the gear, the passenger door, nosewheel steering and the propeller brake, and a shuttle valve lets the system be charged from the ground.
Summary
What to take into the exam Pumps Hand: double acting. Gear (fixed volume): output ∝ RPM, needs ACOV . Swash plate: controls own pressure, starts at max stroke . Positive inlet supply.
ACOV Idles a constant-delivery pump; NRV + accumulator hold pressure. Fast cycling = leaks or low pre-charge. Stuck cut in → relief valve.
Accumulator Stores fluid, damps surges, thermal expansion, emergency supply. Gauge reads system pressure ; pre-charge only when depressurised.
Jacks Single acting (up-lock), unbalanced (more force extending), balanced (steering). Same P both sides → extends .
Hydraulic lock Fluid trapped between piston and NRV or neutral selector: no flow, no movement .
Pressure valves Full-flow relief after pump; thermal relief in isolated lines; priority keeps essential services; reducing for brakes.
Flow valves NRV one way; restrictor in gear UP line ; shuttle : two supplies, one service; sequence; fuse upstream stops leaks.
Systems 2–4 independent systems; PTU moves power, not fluid; RAT → flying controls; HP air: 3300 psi, compressible.
Chapter 4 · Hydraulic Pumps, Valves and Actuators
27
e-books by eatpl.in · © 2026 · Do not copy or distribute
Here is the lesson in one page. Hand pumps are double acting. Gear pumps deliver a fixed volume per turn, so their output follows RPM and they need an automatic cut-out valve; swash-plate pumps control their own pressure and start at maximum stroke; every high-pressure pump needs a positive inlet supply. The cut-out valve idles a constant-delivery pump while a non-return valve and an accumulator hold the pressure; fast cycling means leaks or a low pre-charge. The accumulator stores fluid and damps surges, and once charged its gauge reads system pressure. Unbalanced jacks push harder extending, balanced ones equally both ways, and equal pressure on both sides extends the jack. Fluid trapped against a closed valve gives a hydraulic lock. Relief valves protect, priority valves keep the essential services going, and reducing valves feed the brakes. Restrictors slow the gear, shuttles connect two supplies to one service, and fuses stop a leak. Finally, several independent systems, a power transfer unit and a ram air turbine keep the aircraft flying.