Aircraft Systems · Chapter 3
Hydraulic Principles and Fluids Why aircraft use hydraulic power, how Pascal’s law turns a small force into a large one, the fluids and seals, and the basic open-centre and closed systems with their reservoirs and filters.
P = F ÷ A reservoir pump selector actuator © 2026 eatpl.in. For the personal study of eatpl.in students only. Do not copy or distribute.
e-books by eatpl.in · © 2026 · Do not copy or distribute
Welcome to hydraulics, the muscle of the modern aeroplane. Landing gear, flaps, flight controls, brakes and steering all need large forces, applied smoothly and exactly where they are wanted, often a long way from the pilot. A liquid in a pipe does that beautifully. In this lesson we start with the physics: Pascal’s law, pressure, force and area, and how a small piston can lift a large load. Then we look at the fluids and the seals that hold them, build the simplest working system from six parts, compare open-centre and closed systems, and finish with reservoirs and filters. Questions on all of these come up again and again in the exam.
Roadmap
Hydraulic principles in five steps Hydraulics moves large, remote loads with high power, precise control and a fast response : landing gear, flaps, flight controls, brakes, steering, doors.
1 · Physics Pascal’s law, pressure needs a restriction, F = P × A , the Bramah press and work done.
2 · Fluids and seals Ideal properties, mineral (red) and phosphate ester (purple) fluids, matching seals, handling.
3 · The basic system The six components every system has; open-centre versus closed systems.
4 · Reservoirs Why the air space, why pressurised , and how the stack pipe saves an emergency reserve.
5 · Filters Suction, pressure and return filters, clogging indicators , bypass relief and case drain filters.
Next lesson Pumps, cut-out valves, accumulators, jacks, valves, fuses, PTU, RAT and multiple systems.
Chapter 3 · Hydraulic Principles and Fluids
2
e-books by eatpl.in · © 2026 · Do not copy or distribute
Here is the plan for this lesson. Hydraulics is used wherever an aircraft needs a large force, applied precisely and quickly, at a place far from the cockpit: the landing gear, flaps, flight controls, wheel brakes, nosewheel steering and doors. We start with the physics, Pascal’s law and the relationship between pressure, force and area, which lets a small piston move a big load. Then we look at the fluids, why the choice of fluid fixes the choice of seals, and how to handle them. Third, we build the basic system from six components and compare the open-centre and closed designs. Fourth, the reservoir, which does a lot more than just hold fluid. And finally the filters that keep the fluid clean. The pumps, valves, accumulators and actuators get their own lesson next.
Part 1 · Introduction
Why aircraft use hydraulics Hydraulics transmits power through an almost incompressible liquid in pipes, to jacks (actuators) and motors Used where we need high power, accurate control and rapid response : gear, flaps, flight controls, brakes, steering, doors Modern systems work on high pressure, small displacement : small, light jacks and pipes give large forces Typical pressure: ≈ 1500 psi in light aircraft, 3000–4000 psi in transport aircraft (some new types 5000 psi) A pump only makes flow ; the load on the jack decides the pressure Power transmitted by a liquid pump engine, electric, hand jack remote pipes bend round structure; no cables or rods gear flaps controls brakes High pressure (3000 psi) × small jack = large force small, light pipes · smooth, precise, fast · stiff (oil barely compresses) Typical: light aircraft ≈ 1500 psi · airliners 3000 psi · newest types 5000 psi
Chapter 3 · Hydraulic Principles and Fluids
3
e-books by eatpl.in · © 2026 · Do not copy or distribute
Why do aircraft use hydraulics at all? Because a liquid in a pipe is a superb way of carrying power. The liquid hardly compresses, so a push at one end arrives at the other almost instantly, and the pipes can snake round the structure where rods and cables could never go. Hydraulics is used wherever we need high power, accurate control and a fast response: the landing gear, flaps, flight controls, wheel brakes, nosewheel steering and doors. Modern systems work on the principle of high pressure and small displacement. With three thousand pounds per square inch behind it, a jack only a few centimetres across gives a force of several tonnes, so the parts stay small and light. Light aircraft typically use about fifteen hundred psi, and transport aircraft three to four thousand, with a few new types at five thousand. Remember one idea from the start: the pump makes flow, and pressure only appears when something resists that flow.
Part 1 · Physics
Pascal’s law: pressure acts equally everywhere Pascal’s law : a force applied to a liquid in a confined space is felt equally in all directions So in a closed system the pressure is the same at every point : piston head, cylinder end, wide pipe or narrow pipe No restriction, no pressure : oil pumped through an open pipe just flows; block the end and pressure builds at onceIn a system the restriction is the load on the jack : the pressure it causes is called back pressure Pressure = force ÷ area (pascal, bar or psi)force 5 bar 5 bar 5 bar equal everywhere open pipe: flow, no pressure blocked: pressure builds
Chapter 3 · Hydraulic Principles and Fluids
4
e-books by eatpl.in · © 2026 · Do not copy or distribute
Pascal’s law is the foundation of everything in this chapter. It says that if a force is applied to a liquid in a confined space, that force is felt equally in all directions. Watch the model. When we apply a force and push the piston, the pressure rises everywhere at once: gauge A on the wide pipe and gauge B on the narrow pipe show exactly the same reading. Pipe diameter makes no difference to the pressure; that is a favourite exam trap. The second idea is just as important. A pump does not create pressure. It creates flow. Pump oil through an open-ended pipe and it simply runs out with no pressure at all. Block the end, and pressure rises immediately. In a real system the blockage is the jack and the load it is moving, so the pressure is set by the resistance of the load. That pressure, caused by the loads resisting the jacks, is called back pressure.
Part 1 · Physics
Force = pressure × area Pressure = force ÷ area ; so force = pressure × area System pressure is (nearly) constant , so each service gets the force it needs from the size of its piston : a built-in “gearing” Same pressure on a bigger piston gives a bigger force ; different-diameter jacks exert different forces Units: 1 bar = 100 000 Pa ≈ 14.5 psi; 3000 psi ≈ 207 bar ≈ 20.7 MPa Example: 3000 psi on a 50 mm bore (0.00196 m²) ≈ 40.6 kN , about 4 tonnes Same pressure, different areas same supply: 3000 psi A = 1 in² A = 4 in² 3000 lbf 12 000 lbf P = F ÷ A F = P × A A = F ÷ P
Chapter 3 · Hydraulic Principles and Fluids
5
e-books by eatpl.in · © 2026 · Do not copy or distribute
The working equation of hydraulics is force equals pressure times area. Pressure is force per unit area, so if you know any two of the three you can find the third. Here both jacks see the same supply of three thousand psi. The small one has a piston area of one square inch, so it pushes with three thousand pounds force. The large one has four square inches, so it pushes four times as hard, twelve thousand pounds. That is how one system pressure can serve very different jobs: the designer simply chooses a piston size to suit each load, a kind of built-in gearing. Let us try metric units. Three thousand psi is about two hundred and seven bar, or twenty point seven megapascals. A jack with a fifty millimetre bore has an area of about zero point zero zero two square metres, so it pushes with roughly forty kilonewtons, the weight of four tonnes.
Part 1 · Physics
The Bramah press: a small force lifts a large load LOAD A = 0.002 m² F = 1000 N, moves 0.6 m B = 0.004 m² (twice A) F = 2000 N moves 0.3 m P = 1000 ÷ 0.002 = 500 000 Pa (500 kPa) everywhere Work in = 1000 N × 0.6 m = 600 J · Work out = 2000 N × 0.3 m = 600 J double the area → double the force, half the distance Bramah’s two rules: the smaller the area under load , the greater the pressure generated; the larger the area under pressure , the greater the load it can carry.
Chapter 3 · Hydraulic Principles and Fluids
6
e-books by eatpl.in · © 2026 · Do not copy or distribute
Joseph Bramah used Pascal’s law to build a hydraulic press, and it is the classic exam picture. Look at the small piston on the left. Its area is zero point zero zero two square metres, and we push it with a thousand newtons. Pressure is force over area, so the fluid is at five hundred thousand pascals, five hundred kilopascals, and the gauge shows that same pressure under both pistons. Now look at the large piston on the right. Its area is zero point zero zero four square metres, twice as big, so the same pressure supports a load of two thousand newtons. As the small piston is pushed down, the large one rises, but only half as far, because the volume of fluid leaving one cylinder must enter the other. Nothing is free: we doubled the force but halved the distance.
Part 1 · Physics
Work done: what you gain in force you lose in distance Work = force × distance ; with no friction, work in = work outThe fluid volume pushed out of A equals the volume entering B: area × distance is the same on both sides So the distance moved is inversely proportional to the area Example: A moves 0.6 m with 1000 N; B (twice the area) moves 0.3 m with 2000 N; both 600 J Example: small piston 12 cm² pushed down 10 cm ; large piston 24 cm² goes up 5 cm Volume out = volume in d d/2 area a area 2a swept filled Work = force × distance (no friction)A: 1000 N × 0.6 m = 600 J B: 2000 N × 0.3 m = 600 J Distance moved ∝ 1 ÷ area
Chapter 3 · Hydraulic Principles and Fluids
7
e-books by eatpl.in · © 2026 · Do not copy or distribute
The Bramah press seems to give something for nothing, but the energy books always balance. Work is force times distance, and if we ignore friction, the work we put in at piston A equals the work we get out at piston B. The easiest way to see why is to follow the fluid. The volume swept by piston A, its area times its travel, is pushed through the pipe and must fill the same volume under piston B. Piston B has twice the area, so it rises only half as far. In the example, piston A moves zero point six metres with a thousand newtons, six hundred joules. Piston B moves zero point three metres with two thousand newtons, also six hundred joules. A typical exam version: a twelve square centimetre piston is pushed down ten centimetres; the twenty four square centimetre piston goes up five centimetres. Up, not down, and half the distance.
Part 1 · Worked examples
Exam calculations, step by step Two rules do every sum: P = F ÷ A (the pressure is the same everywhere) and F = P × A on each piston. Keep the units consistent.
Problem Working Answer 50 N on a 25 cm² piston; force on a 250 cm² piston to balance? P = 50 ÷ 25 = 2 N/cm²; F = 2 × 250 500 N 25 N on a 20 cm² piston; force on a 100 cm² piston? P = 25 ÷ 20 = 1.25 N/cm²; F = 1.25 × 100 125 N 100 N on jacks of 0.02 m² and 0.04 m²: pressure in each? 100 ÷ 0.02 and 100 ÷ 0.04 5000 Pa and 2500 Pa 3000 Pa on actuators of 0.02 m² and 0.04 m²: forces? 3000 × 0.02 and 3000 × 0.04 60 N and 120 N 3000 psi on a 100 cm² piston, rod-linked to a 500 cm² piston pressing a second fluid: gauge reading? Force = 3000 × 100; P₂ = force ÷ 500 = 3000 × 100 ÷ 500 600 psi 1500 N on 0.002 m², output piston 0.003 m², input moves 0.025 m: force, pressure, work? P = 1500 ÷ 0.002; F = P × 0.003; W = 1500 × 0.025 2250 N, 750 000 Pa, 37.5 J
Two pistons on one rod share the same force , not the same pressure: the pressure changes in inverse proportion to the area.
Chapter 3 · Hydraulic Principles and Fluids
8
e-books by eatpl.in · © 2026 · Do not copy or distribute
First: fifty newtons on a twenty five square centimetre piston gives two newtons per square centimetre; on two hundred and fifty square centimetres that balances five hundred newtons. Second: twenty five newtons on twenty square centimetres is one point two five newtons per square centimetre; on a hundred square centimetres, a hundred and twenty five newtons. Third: a hundred newtons on point zero two square metres is five thousand pascals; on point zero four it is two thousand five hundred. Fourth: three thousand pascals on the same two jacks gives sixty and a hundred and twenty newtons. The fifth one is a trap. Two pistons share one rod, so the force is common, not the pressure. Three thousand psi times a hundred square centimetres, divided by five hundred, gives six hundred psi. Last: fifteen hundred newtons on point zero zero two square metres is seven hundred and fifty thousand pascals, giving two thousand two hundred and fifty newtons, and the work done is thirty seven and a half joules.
Part 1 · Physics
A passive system: light aircraft brakes In a passive system, pressure is made only when needed , by pushing on a piston Example: light aircraft brakes: a master cylinder at each pedal and a slave cylinder at each wheel Pedal force on the small master piston → pressure → larger force at the slave piston on the brake disc A small reservoir tops up the master cylinder for wear and small leaks An active (power) system instead keeps a pump running and holds pressure ready for many services Passive system: pressure only when the pedal is pushed toe brake pedal master cylinder reservoir slave cylinder disc small master piston, larger slave piston: force multiplied at the wheel
Chapter 3 · Hydraulic Principles and Fluids
9
e-books by eatpl.in · © 2026 · Do not copy or distribute
The Bramah press is a passive hydraulic system: pressure exists only while someone is pushing on the first piston. A light aircraft’s brakes work exactly this way. Each toe brake pedal pushes the piston of a small master cylinder. The pressure travels down a thin pipe to a slave cylinder at the wheel, whose larger piston squeezes the brake pads against the disc. Because the slave piston is bigger, the pilot’s foot force is multiplied, and the further the pedal goes, the harder the brakes bite. A little reservoir above the master cylinder keeps it topped up as the pads wear. Larger aircraft need something different: an active, or power, system in which pumps run continuously and pressure is kept ready for many services at once. That is what the rest of this lesson builds.
Part 2 · Fluids and pipelines
An almost incompressible liquid, and friction Hydraulic fluid is treated as incompressible up to about 4000 psi (≈ 276 bar) ; above that it compresses slightly At ≈ 350 bar oil loses only about 1% of its volume; air would be squeezed to about 1/300 That stiffness gives instant, precise response; air in the system makes it spongy, so it must be bled out Some force is always lost to friction: pistons in cylinders, rods in glands, and fluid against pipe walls Line friction rises with velocity, length, small bore, rough finish, bends and viscosity ; the practical cure is the correct fluid Squeeze both to about 350 bar oil ≈ 99% of volume left air: ≈ 1/300 left air Friction in the lines grows with: • fluid velocity • pipe length, bore and internal finish • the number of bends • fluid viscosity Seals and glands add friction at pistons and rods too
Chapter 3 · Hydraulic Principles and Fluids
10
e-books by eatpl.in · © 2026 · Do not copy or distribute
Why use a liquid rather than air? Because a liquid hardly compresses. For practical purposes hydraulic fluid is incompressible up to around four thousand psi, about two hundred and seventy six bar. Squeeze a cylinder of oil to around three hundred and fifty bar and it loses only about one per cent of its volume, while the same cylinder of air would end up at about one three-hundredth of its size. That stiffness is what makes hydraulics feel solid and respond instantly. That is also why trapped air is bad news: it makes the system spongy and jerky, so it must be bled out. Some force is always lost to friction between pistons and cylinders, between rods and their glands, and between the fluid and the pipe walls. Pipe friction grows with the velocity of the fluid, with long, narrow, rough pipes, with every bend and with the viscosity of the oil. Big pipes would help but weigh too much, so the practical answer is the correct fluid.
Part 2 · Fluids
The ideal hydraulic fluid No real fluid is perfect, but the specification aims for all of these:
Incompressible Relatively incompressible up to about 276 bar , so operation is instant.
Lubricating Good lubricating properties for metal and rubber : pumps, pistons and seals.
Viscosity and temperature Steady viscosity, high boiling point (no vapour lock or cavitation), low freezing point : roughly −70 to +80 °C.
Fire Flash point above 100 °C and ideally non-flammable .
Stable Chemically inert , non-corrosive, resistant to evaporation.
Clean running Free from sludging and foaming .
Practical Good storage life, reasonably priced and readily available.
Seal-friendly Compatible with the seal material chosen for the system.
Chapter 3 · Hydraulic Principles and Fluids
11
e-books by eatpl.in · © 2026 · Do not copy or distribute
What would the perfect hydraulic fluid be like? First, it should be relatively incompressible, up to about two hundred and seventy six bar, so the system responds instantly. It must lubricate, because the same fluid has to keep pump parts, pistons and rubber seals moving freely. Its viscosity should stay sensible over a wide temperature range, roughly minus seventy to plus eighty degrees, with a high boiling point so it does not vaporise in the pump inlet and cause vapour locking or cavitation, and a low freezing point. For fire safety it should have a flash point above a hundred degrees and ideally not burn at all. It should be chemically inert and non-corrosive, resist evaporation, and not form sludge or foam. It should store well and be reasonably cheap and easy to get. And it must suit the seals; that last point decides which fluid goes in which aircraft, as we will see next.
Part 2 · Fluids
Mineral and phosphate-ester fluids The seal material decides the fluid . Never mix fluids, and never use one in a system built for another.
Mineral (petroleum) based Phosphate ester (synthetic), e.g. Skydrol Vegetable based (obsolete) Specification DEF STAN 91-48 (was DTD 585); MIL-H-5606 (US) Skydrol and similar Castor oil types Colour Red Purple (Type 500A); green (Type 700)Blue Seals Neoprene (synthetic rubber)Butyl (synthetic rubber)Natural rubber Fire Flammable Fire resistant ; higher boiling point, less cavitationFlammable Used in Light aircraft, older types, helicopters Modern transport aircraft Very old aircraft Hazards Skin irritant Harms skin and eyes , strips paint , attacks perspex—
Colour is a useful indication and helps trace leaks, but the specification is only confirmed from the aircraft manual and sealed containers or the approved replenishment rig.
Chapter 3 · Hydraulic Principles and Fluids
12
e-books by eatpl.in · © 2026 · Do not copy or distribute
There are two families of hydraulic fluid in common use. Mineral fluid is a refined petroleum oil, coloured red. The British specification is DEF STAN ninety one forty eight, which replaced the old DTD five eight five, and the American equivalent is MIL-H five six zero six. It is used with neoprene seals, and you find it in light aircraft, older types and many helicopters. Its weakness is that it burns. Modern transport aircraft use a phosphate ester, synthetic fluid, best known as Skydrol. It is coloured purple, or green in one older type, and it needs butyl rubber seals. Its big advantage is that it is fire resistant, and its higher boiling point makes it less prone to cavitation. But it is nasty stuff: it harms skin and eyes and strips paint. Long ago, vegetable fluids, coloured blue, were used with natural rubber seals. Colour is a good indication, but only the manual and a sealed container confirm the specification.
Part 2 · Fluids
Handling fluids: the golden rules Use only the specified fluid or its approved alternative; never mix fluids Wrong fluid → seals swell or break down → internal and external leaks , blocked filters, high temperature, corrosion, system failure Confirm the specification from the aircraft manual ; take fluid only from sealed containers or the approved rig Fluids attack skin, eyes, paint, sealants, rubber and perspex : wear gloves and goggles, wipe spills at once Milky fluid shows aeration (or water): investigate it; air in the system must be bled outsealed can right fluid, right seals wrong fluid: seals swell, leak Milky or cloudy fluid = air (aeration) or water in it Investigate; do not just fly on Air in the system: bleed it out
Chapter 3 · Hydraulic Principles and Fluids
13
e-books by eatpl.in · © 2026 · Do not copy or distribute
Here are the golden rules for handling hydraulic fluid. Only ever use the fluid specified for that aircraft, or its approved alternative, and never mix two kinds. If the wrong fluid goes in, the seals soften, swell or break down, and you get leaks inside the components and outside at the actuators, debris blocking the filters, high temperatures and corrosion: in the end, failure of the system. Do not trust colour alone. Check the specification in the aircraft manual and take fluid only from sealed containers or the approved replenishment rig, because an opened can may be contaminated with water or dirt. Both fluid types attack skin, eyes, paintwork, sealing compounds, rubber and perspex, so wear gloves and goggles and clean up spills straight away. Finally, fluid that looks milky or cloudy has air in it, aeration, or possibly water. That is not normal: it must be investigated, and any air in the system is bled out.
Part 2 · Seals
Seals: keeping the fluid in Static seals (gaskets, packings) are squeezed between fixed faces; dynamic seals sit between sliding surfacesU and V rings seal against pressure from one direction only ; O-rings and square-section seals work both waysAt high pressure an O-ring has a stiff backing ring so it cannot be squeezed (extruded) into the gap Dynamic seals need lubrication: a slight wetting of the rod is acceptable A wiper ring keeps grit off the rod; the seal material must match the fluid (neoprene: mineral; butyl: Skydrol ) cylinder wall piston / rod O-ring + backing either direction U-ring one direction V-ring stack one direction square section either direction rod retracts Wiper ring: scrapes grit off the rod before it can reach the seals Dynamic seals need lubrication: a slight wetting of the rod is normal
Chapter 3 · Hydraulic Principles and Fluids
14
e-books by eatpl.in · © 2026 · Do not copy or distribute
Seals stop the fluid leaking out and stop it bypassing pistons inside components. Static seals, such as gaskets and packings, are simply squeezed between two fixed surfaces. Dynamic seals sit between surfaces that slide, like a piston in its cylinder or a rod in its gland, and they come in many shapes. U-rings and V-rings only seal against pressure coming from one direction, so they are fitted the right way round. O-rings and square-section seals work with pressure from either side. At high pressure an O-ring is backed by a stiff backing ring, which keeps its shape and stops it being squeezed into the gap between the moving parts. A dynamic seal needs a film of oil to work, so a slight wetting of the rod is quite normal. Grit destroys seals, so actuators often have a wiper ring that scrapes the rod clean as it goes in. And remember: the seal material must match the fluid.
Part 3 · The basic system
Six components common to every hydraulic system EXTEND reservoir pump filter relief valve selector valve actuator (jack) red = pressure blue = return / suction Reservoir · pump (hand, engine or electric) · selector (directs flow to one side of the jack and gives the other side a return path) · jack · filter · relief valve
Chapter 3 · Hydraulic Principles and Fluids
15
e-books by eatpl.in · © 2026 · Do not copy or distribute
Every hydraulic system, from a light aircraft to an airliner, is built from six basic components. The reservoir stores the fluid, feeds the pump and takes back the fluid returning from the actuators. The pump, driven by hand, by the engine or by an electric motor, delivers a flow of fluid into the system. The filter keeps that fluid clean. The relief valve is the safety device: if pressure ever climbs too high, it opens and dumps fluid back to the reservoir. The selector valve is the pilot’s control. It directs the fluid to the chosen side of the actuator and, just as importantly, gives the fluid displaced from the other side a path back to the reservoir. Watch what happens when we select extend: red pressure flows to the cap end, the piston moves, and blue fluid returns from the rod side, until the jack reaches the end of its travel. Finally the actuator, or jack, turns that fluid flow into the movement that does the work.
Part 3 · System types
The open-centre system With no service selected, pump flow passes through the open centre of the selectors and straight back to the reservoir The pump runs off-loaded : little pressure, but a flow that still cools and lubricates it Select a service: the centre closes, fluid goes to the jack; at the end of travel pressure builds until the selector returns to neutral The relief valve limits pressure if the selector does not return to neutral Advantage: simple . Disadvantage: only one service at a time . Used in light aircraft (gear, flaps); also self-contained power packsNEUTRAL open centre low-pressure circulation relief jack (not selected) Simple, but only one service at a time
Chapter 3 · Hydraulic Principles and Fluids
16
e-books by eatpl.in · © 2026 · Do not copy or distribute
The simplest powered system is the open-centre system. Look at the selector in its neutral position: the centre is open, so the pump’s flow goes in, straight through the selector, and back to the reservoir. Because nothing restricts it, there is very little pressure. The pump is off-loaded, yet fluid keeps flowing through it to cool and lubricate it. Now we select a service. The centre closes, the flow is sent to the actuator, and the gauge rises to the pressure needed to move the load. When the jack reaches the end of its travel, the flow stops and pressure builds quickly. The selector then returns to neutral, off-loading the pump again, ready for the next selection. If it fails to return, the relief valve limits the pressure. The big advantage is simplicity. The big drawback is that only one service can be operated at a time, which suits light aircraft that only move the gear and flaps briefly.
Part 3 · System types
The closed (closed-centre) system Operating pressure is held all the way up to the selector valves, even when nothing is movingPressure is almost constant in the centre of the system, so many services can operate at once Something must stop the pump overloading: an automatic cut-out valve (fixed-volume pump), a variable-volume pump , or a pressure switch on an electric pump A non-return valve and an accumulator hold the pressure; the pump still needs a cooling flow Used in almost all large aircraft NRV accumulator closed-centre selectors to several services at once full pressure held up to the selectors Pump unloaded by: an ACOV (fixed volume pump), a variable-volume pump, or a pressure switch (electric pump)
Chapter 3 · Hydraulic Principles and Fluids
17
e-books by eatpl.in · © 2026 · Do not copy or distribute
Large aircraft use the closed, or closed-centre, system. Operating pressure is kept all the way up to the selector valves, even when no jack is moving. Watch the model. The pump runs, fluid passes the non-return valve, and the accumulator charges until the gauge reads three thousand psi. Now nothing is flowing, yet the full pressure is waiting at the selector. Because the pressure in the centre of the system is almost constant, several services can be operated at the same time. The pump must not keep fighting against a closed system, so it is off-loaded in one of three ways: an automatic cut-out valve with a fixed-volume pump, a variable-volume pump that reduces its own delivery as pressure rises, or, in simple systems, a pressure switch that turns an electric pump on and off. Now we select extend, and the accumulator and the pump supply the flow straight away. When the jack reaches the end of its travel, the pump builds the pressure back up.
Part 3 · System types
Open-centre versus closed systems Open-centre Closed (closed-centre) Pressure at rest Low: pump flow returns freely to the tank Full system pressure held up to the selectorsServices at once One at a timeMany simultaneouslyPump off-loading Through the open centre of the selectors ACOV, variable-volume pump, or pressure switch Cooling flow when off-loaded Yes: the flow passes through the pump Yes: a small idling or case flow is kept Accumulator Not normally Yes: stores pressure, damps surges Typical use Light aircraft (gear, flaps), power packs Most large aircraft Main advantage / drawback Simple / slow, one service at a time Instant response, many services / more complex
Exam trap: an off-loaded pump still needs a cooling and lubricating flow in both systems.
Chapter 3 · Hydraulic Principles and Fluids
18
e-books by eatpl.in · © 2026 · Do not copy or distribute
Let us put the two systems side by side. At rest, the open-centre system has low pressure, because the pump’s flow runs freely back to the reservoir, while the closed system holds full pressure right up to the selectors. The open-centre system can work only one service at a time; the closed system can work many at once. The open-centre pump is off-loaded through the open centre of the selectors; the closed system uses an automatic cut-out valve, a variable-volume pump or a pressure switch. In both cases the off-loaded pump still has fluid passing through it to cool and lubricate it, and the exam likes to offer you the false statement that no cooling flow is needed. The closed system nearly always has an accumulator. The open-centre system is used in light aircraft and self-contained power packs; the closed system is used in most large aircraft. Simple versus capable: that is the trade-off.
Part 4 · Reservoirs
What the reservoir does Stores the fluid; its air space allows for volume changes and cushions surges of returning fluidJack ram displacement : a jack holds less fluid retracted than extended (the rod takes up room)Thermal expansion : fluid volume grows with temperatureGives a head of fluid to the pump and compensates for small leaks So the level varies with jack positions, accumulator charge and temperature: check it in the specified condition air space fluid level varies with: • jack positions • accumulator charge • temperature head of fluid for the pump Storage + air space for: displacement · expansion · small leaks
Chapter 3 · Hydraulic Principles and Fluids
19
e-books by eatpl.in · © 2026 · Do not copy or distribute
The reservoir stores the fluid, but it also keeps an air space above it, because the volume of fluid out in the system keeps changing, and that space cushions surges of fluid coming back from the system. Watch the actuator. As it extends, fluid is pumped into the cap side, but less comes back from the rod side, because the rod itself takes up room. So the reservoir level falls. When it retracts, the fluid comes back and the level rises again. This is called jack ram displacement. Fluid also expands as it warms. The reservoir also provides a head of fluid to feed the pump, and a reserve that makes up for small leaks. Because the level depends on where the jacks are, whether the accumulators are charged and the temperature, it must be checked in the condition the manual specifies. Fill it to full with the system depressurised, then pressurise the system, and the level falls below full as the accumulators charge.
Part 4 · Reservoirs
Why reservoirs are pressurised Pressurising gives a positive fluid pressure at the pump inlet , so the pump never starves: no cavitation It stops air bubbles forming (foaming) in the fluid at high altitude , where outside pressure is low Air comes from the engine compressor (bleed air) or the cabin pressurisation system; some use a bootstrap piston Fitted with a relief valve (no over-pressurising), contents transmitter, filler cap, often a temperature probe An unpressurised tank has a vent : it stops a partial vacuum or over-pressure as the level changes bleed air (or cabin air) relief valve positive inlet pressure no cavitation or foaming contents transmitter Non-pressurised tank: a vent prevents a partial vacuum or over-pressure
Chapter 3 · Hydraulic Principles and Fluids
20
e-books by eatpl.in · © 2026 · Do not copy or distribute
Why are jet aircraft reservoirs pressurised? A high-pressure pump must have a positive supply of fluid at its inlet. If the inlet pressure is too low, the pump starves, vapour and air bubbles form, and the collapsing bubbles erode the pump. That is cavitation. At high altitude the outside air pressure is low, so dissolved air would also come out of the fluid as bubbles, making it foam. Pressurising the air space above the fluid prevents both problems. The air usually comes from the compressor section of the engine, as bleed air, or from the cabin pressurisation system; some designs use a bootstrap reservoir, in which system pressure acting on a small piston pressurises the fluid. The reservoir has a relief valve so it cannot be over-pressurised, a contents transmitter, a filler cap and often a temperature probe. A simple unpressurised reservoir has a vent instead, so the level can rise and fall without a vacuum or an over-pressure.
Part 4 · Reservoirs
The stack pipe keeps an emergency reserve normal level lowest level after a leak engine-driven pumps emergency hand pump de-aerator baffles A B C D A stack pipe: main pumpsB bottom outlet: emergencyC return line (side)D pressurising air / ventMain (engine-driven) pumps and non-essential services draw through the stack pipe (only the fluid above its top ); the emergency hand pump draws from the bottom of the reservoir.
Chapter 3 · Hydraulic Principles and Fluids
21
e-books by eatpl.in · © 2026 · Do not copy or distribute
Here is a reservoir in section, with the four connections the exam likes to label. The stack pipe, A, stands up from the floor of the tank, and the engine-driven pumps draw their fluid through it, so they can only use the fluid above its top. The outlet at the very bottom, B, feeds the emergency hand pump. The return line, C, comes in through the side above the fluid, often through a de-aerator, and the connection at the top, D, is the pressurising air or the vent. Baffles inside stop the fluid surging and swirling as the aircraft manoeuvres. Now imagine a pipe bursts in the main system and we have a leak. The level falls, until it drops below the top of the stack pipe. At that point the engine pumps lose their supply, but they cannot pump the tank dry. The fluid below the top of the stack pipe is still there, reserved for the hand pump and the emergency system.
Part 5 · Filters
Filters keep the fluid clean Suction (low-pressure) filter before the pump protects the pump ; pressure (high-pressure) filter downstream of the pump protects the system Often a return filter too, and small filters at component inlets; constant-pressure pumps have a case drain filter to monitor pump condition A differential pressure indicator (button or lamp) shows a clogging element; a bimetal lock-out stops false warnings from cold, thick fluid Some filters have a bypass relief valve : when clogged, unfiltered fluid flows on, so elements are changed at set intervals Paper elements are thrown away; wire-cloth elements can be cleaned (ultrasonically) in clean out clog indicator (ΔP) bimetal lock-out when cold bypass valve opens when blocked Suction filter (LP): protects the pump · Pressure filter (HP): downstream of pump, protects the system · Return filter · Case drain
Chapter 3 · Hydraulic Principles and Fluids
22
e-books by eatpl.in · © 2026 · Do not copy or distribute
Dirt is the enemy of hydraulics: it scores pistons, jams valves and cuts seals. So filters are fitted on both sides of the pump. A suction, or low-pressure, filter before the pump protects the pump itself, and a pressure, or high-pressure, filter fitted downstream of the pump keeps the fluid clean as it goes to the system. There is often a return filter as well, and small filters at the inlets of individual components. Constant-pressure pumps have a case drain filter on their small leakage flow; debris caught there tells the engineers about the pump’s condition. As an element clogs, the pressure drop across it rises, and a differential pressure indicator pops out a button or lights a lamp. A bimetal spring stops a false warning when the fluid is cold and thick. Some filters have a bypass relief valve that lets unfiltered fluid through once the element is blocked, so those elements are changed at regular intervals. Paper elements are discarded; wire-cloth ones can be cleaned.
Summary
What to take into the exam Pascal Pressure in a confined liquid acts equally in all directions ; same everywhere, whatever the pipe size. No restriction, no pressure.
F = P × A Bigger piston, bigger force, shorter travel . Work in = work out. 12 → 24 cm²: 10 cm down, 5 cm up.
Fluids Mineral: red, neoprene , flammable. Phosphate ester (Skydrol): purple, butyl , fire resistant. Never mix.
Seals U and V rings one way; O-rings both ways, with backing rings at high pressure; wiper rings keep grit out.
Six parts Reservoir, pump, selector, jack, filter, relief valve. High pressure, small displacement.
Open vs closed Open-centre: simple, one service at a time . Closed: pressure held, many services , large aircraft.
Reservoir Displacement, expansion, leaks, head for pump. Pressurised (bleed air) against cavitation and foaming. Stack pipe reserve.
Filters Suction protects the pump, pressure (downstream) protects the system; ΔP indicator; bypass; case drain shows pump health.
Chapter 3 · Hydraulic Principles and Fluids
23
e-books by eatpl.in · © 2026 · Do not copy or distribute
Let us pull it together. Pascal’s law: pressure in a confined liquid acts equally in all directions, and is the same everywhere, whatever the pipe size; and without a restriction there is no pressure. Force equals pressure times area, so a bigger piston gives a bigger force but moves a shorter distance, and the work in equals the work out. Mineral fluid is red, used with neoprene seals, and burns; phosphate ester fluid is purple, used with butyl seals, and resists fire. Never mix them. U and V rings seal one way, O-rings both ways. Every system has a reservoir, pump, selector, jack, filter and relief valve, working on high pressure and small displacement. Open-centre systems are simple but work one service at a time; closed systems hold pressure and serve many at once. The reservoir allows for displacement, expansion and leaks, is pressurised against cavitation, and its stack pipe keeps a reserve for the emergency pump. And filters protect the pump and the system.