Aircraft Systems · Chapter 18
Oxygen Systems Why aircraft carry oxygen and how it reaches the people who need it: hypoxia and time of useful consciousness, the carriage rules, crew diluter-demand and quick-donning masks, passenger drop-out masks, chemical generators, portable sets, smoke hoods and safety.
© 2026 eatpl.in. For the personal study of eatpl.in students only. Do not copy or distribute.
e-books by eatpl.in · © 2026 · Do not copy or distribute
Chapter eighteen is about oxygen. Above about ten thousand feet the air no longer carries enough oxygen into the blood for us to think clearly, and at airliner cruising levels a pilot without oxygen has only seconds of useful consciousness. So aircraft carry oxygen for the crew, for the passengers after a decompression, for passengers who are unwell, and for fighting smoke and fumes. We will see why it is needed, what the rules require, and how each system stores and delivers it.
Chapter 18
Oxygen: who needs it, and how it gets there 1 Why hypoxia and TUC 2 Rules who needs how much 3 Crew diluter-demand, masks 4 Passengers drop-out masks, generators 5 Portable first aid, PBE, smoke hoods 6 Safety oil, fire, leaks Why and when Hypoxia, partial pressure, useful consciousness; the carriage rules and mask numbers.
Crew systems Gaseous storage, continuous flow, diluter-demand regulators, quick-donning masks.
Passenger systems Drop-out masks, chemical generators, first-aid and portable oxygen.
Smoke and safety PBE and smoke hoods; oil, fire and leak precautions.
Chapter 18 · Oxygen Systems
2
e-books by eatpl.in · © 2026 · Do not copy or distribute
Here is the plan. We start with why oxygen is needed: hypoxia, why it happens even though the air is still twenty one per cent oxygen, and how little time you have to act at height. Then the rules: how much oxygen the crew and passengers must have in pressurised and unpressurised aircraft, and how many masks must be fitted. Next, the crew systems: how oxygen is stored, the continuous flow system, the diluter-demand regulator with its selections, and the quick-donning mask. Then the passenger systems: the masks that drop from the ceiling, the chemical oxygen generator, first-aid and portable oxygen. Finally, protection against smoke with protective breathing equipment and smoke hoods, and the safety rules for handling oxygen.
Part 1 · Why oxygen
Hypoxia Hypoxia : too little oxygen reaching the body's tissuesAbove about 10,000 ft it can affect performance Signs: personality change , impaired judgement , muscular and memory impairment, sensory loss Then confusion, unconsciousness , and finally death Drills: 1. oxygen on , 2. descend to where the air carries enough oxygen Personality change over-confidence, euphoria Impaired judgement poor decisions, slow thinking Muscular impairment clumsy, poor co-ordination Memory impairment tasks forgotten Sensory loss vision (colour, night), touch Loss of consciousness confusion → unconscious → death getting worse, often unnoticed Cure: 1. OXYGEN on 2. DESCEND
Chapter 18 · Oxygen Systems
3
e-books by eatpl.in · © 2026 · Do not copy or distribute
The body takes its oxygen from blood that has been loaded in the lungs. If too little oxygen reaches the tissues, we have hypoxia, and the crew must be able to recognise it, because it creeps up unnoticed. The early signs are an apparent change of personality, often over-confidence, and impaired judgement. Then come muscular impairment, so movements become clumsy, memory impairment, and loss of senses such as colour and night vision. If nothing is done, the person becomes confused, semi-conscious, unconscious, and finally dies. Hypoxia can occur above about ten thousand feet, so crews must know the oxygen drills for their aircraft before they fly higher than that. The drills themselves are simple and must become automatic: first, get oxygen, normally by putting on the mask; second, descend to a level where the air carries enough oxygen for the body's needs.
Part 1 · Why oxygen
Same percentage, less pressure Air is 20.95 % oxygen at every altitude, and still so when it is compressed for the cabin What falls with height is the partial pressure of oxygen Partial pressure drives oxygen from the lungs into the blood About half the sea-level value by 18,000 ft Cure: raise the percentage breathed (oxygen) or the pressure (pressurise / descend) 0 40 80 120 160 0 10k 20k 30k 40k altitude (ft) oxygen partial pressure (mmHg) sea level 159 10,000 ft: 110 18,000 ft: 80 (half) 34,000 ft: 39 The share stays 20.95 % the pressure falls
Chapter 18 · Oxygen Systems
4
e-books by eatpl.in · © 2026 · Do not copy or distribute
A common misunderstanding is that there is less oxygen in the air at altitude. The percentage is exactly the same: about twenty one per cent at every height, and still twenty one per cent when the air is compressed and pumped into a pressurised cabin. What changes is the pressure. Oxygen moves from the lungs into the blood because of its partial pressure, its share of the total pressure. The graph is computed from the standard atmosphere. At sea level the oxygen partial pressure is about a hundred and fifty nine millimetres of mercury. At ten thousand feet it is a hundred and ten, by eighteen thousand feet it is about half the sea-level value, and at thirty four thousand feet it is only thirty nine. There are two ways to fix it: raise the percentage of oxygen you breathe, which is what the oxygen system does, or raise the pressure, by pressurising the cabin or descending.
Part 1 · Why oxygen
Time of useful consciousness TUC : time from losing the oxygen supply until you can no longer help yourself It is shorter than the time to unconsciousness 18,000 ft: about 30 min ; 25,000 ft: 3–5 min 30,000 ft: 90–45 s ; 35,000 ft: 45–30 s ; 40,000 ft: about 20 s ; 45,000 ft: about 12 s Exertion, smoking and fatigue shorten it; so does a rapid decompression Time of useful consciousness (log scale) 10 s 1 min 5 min 30 min 18,000 ft about 30 min 22,000 ft 5 – 10 min 25,000 ft 3 – 5 min 30,000 ft 45 – 90 s 35,000 ft 30 – 45 s 40,000 ft about 15 – 20 s 45,000 ft about 12 s Exam: 25,000 ft ≈ 3 min · 30,000 ft 90–45 s · 40,000 ft ≈ 20 s
Chapter 18 · Oxygen Systems
5
e-books by eatpl.in · © 2026 · Do not copy or distribute
The time of useful consciousness is the time you have, after losing an adequate oxygen supply, to recognise what is happening and do something about it. It is not the time until you pass out; it is the shorter time until you are so impaired that you can no longer take steps to help yourself. Look at how fast it shrinks. At eighteen thousand feet you have about thirty minutes. At twenty five thousand feet, three to five minutes. At thirty thousand, between ninety and forty five seconds. At thirty five thousand, forty five to thirty seconds, and at forty thousand feet about twenty seconds, falling to about twelve seconds at forty five thousand. These are average figures for someone sitting still; exercise, smoking, fatigue and a rapid decompression all make them shorter. That is why crew masks at high level must go on in seconds.
Part 1 · Why oxygen
Key altitudes and effects Altitude What happens 5,000 ft Night vision starts to suffer 8,000 ft Normal maximum cabin altitude; crew efficiency starts to be impaired above it 10,000 ft Highest altitude without oxygen at which flying efficiency is not seriously impaired ; hypoxia above; cabin altitude warning 14,000 / 15,000 ft Passenger masks drop at 14,000 ft , so they are on before 15,000 ft , above which all passengers need oxygen about 34,000 ft Breathing 100 % oxygen here gives the same alveolar oxygen as air at sea level about 40,000 ft 100 % oxygen only equals air at about 10,000 ft; above this, pressure breathing is needed Rapid decompression Sudden, extreme drop in temperature , misting; TUC shortenedSusceptibility Increased by smoking (carbon monoxide), alcohol, fatigue, cold, exertion, illness
Chapter 18 · Oxygen Systems
6
e-books by eatpl.in · © 2026 · Do not copy or distribute
A few altitudes come up again and again. Eight thousand feet is the normal maximum cabin altitude, and above it crew efficiency starts to be impaired. Ten thousand feet is the highest altitude at which you can fly without oxygen and not suffer a serious loss of efficiency; above it hypoxia appears, and a cabin altitude warning sounds on the flight deck. Passenger masks drop at fourteen thousand feet, so that they are on before fifteen thousand, above which every passenger needs oxygen. At about thirty four thousand feet, breathing one hundred per cent oxygen gives the same oxygen pressure in the lungs as breathing air at sea level. At about forty thousand feet, even pure oxygen only matches air at ten thousand feet, so above that oxygen must be supplied under pressure. A rapid decompression brings a sudden, extreme drop in temperature. And remember that smoking increases susceptibility to hypoxia, because carbon monoxide takes up space on the red blood cells.
Part 2 · The rules
Supplemental oxygen: pressurised aeroplanes Who Supply needed (cabin pressure altitude) Flight crew on duty All the time above 13,000 ft ; between 10,000 and 13,000 ft after the first 30 min ; never less than 30 min (certificated to 25,000 ft or less) or 2 h (above 25,000 ft) Required cabin crew All the time above 13,000 ft (not less than 30 min); 10,000–13,000 ft after the first 30 min 100 % of passengersAll the time above 15,000 ft , never less than 10 min 30 % of passengersAll the time between 14,000 and 15,000 ft 10 % of passengersBetween 10,000 and 14,000 ft , after the first 30 min
"Passengers" means those actually carried, including infants. Supplemental oxygen is the supply used after a depressurisation .
Chapter 18 · Oxygen Systems
7
e-books by eatpl.in · © 2026 · Do not copy or distribute
Supplemental oxygen is the supply for use after the cabin loses pressure, and the rules depend on the cabin pressure altitude. For a pressurised aeroplane, the flight crew on duty need oxygen all the time the cabin is above thirteen thousand feet, and between ten and thirteen thousand after the first thirty minutes there. Whatever happens, their supply must last at least thirty minutes for aircraft certificated to twenty five thousand feet or below, and two hours above that. The required cabin crew need oxygen above thirteen thousand feet, at least thirty minutes, plus ten to thirteen thousand after the first half hour. For passengers there are three bands: all of them above fifteen thousand feet, for at least ten minutes; thirty per cent between fourteen and fifteen thousand; and ten per cent between ten and fourteen thousand, after the first thirty minutes. Passengers means those actually carried, including infants.
Part 2 · The rules
Sizing the supply: the descent profile Supply based on the most critical point for a decompression, then an emergency descent Crew minimum: descent to 10,000 ft in 10 min , then 20 min (or 110 min for types above 25,000 ft) at 10,000 ft Passengers: descent to 15,000 ft in 10 min for the 10-minute minimum Above 25,000 ft : flight crew masks must be quick-donning Not above 25,000 ft and can descend to 13,000 ft in 4 min : reduced supply allowed above 15,000: 100 % of passengers 14–15,000: 30 % 10–14,000: 10 % (after 30 min) 0 10k 20k 30k 40k 0 10 20 30 40 minutes after decompression cabin altitude (ft) 10 min descent, then 20 min (or 110 min) at 10,000 ft decompression at 37,000 ft
Chapter 18 · Oxygen Systems
8
e-books by eatpl.in · © 2026 · Do not copy or distribute
How big must the supply be? It is worked out by assuming the cabin loses pressure at the worst possible point of the route, and that the aircraft then makes an emergency descent to a safe altitude. The graph shows a decompression at thirty seven thousand feet followed by a constant-rate descent to ten thousand feet in ten minutes. The crew minimum is exactly this: ten minutes of descent plus twenty minutes at ten thousand feet, which gives thirty minutes, or plus a hundred and ten minutes, giving two hours, for aircraft certificated above twenty five thousand feet. The passenger ten-minute minimum assumes a descent to fifteen thousand feet in ten minutes. Above twenty five thousand feet the flight crew must have quick-donning masks. An aeroplane not certificated above twenty five thousand feet that can always descend to thirteen thousand feet within four minutes may carry a reduced supply.
Part 2 · The rules
Supplemental oxygen: unpressurised aeroplanes Who Supply needed (pressure altitude) Flight crew on duty All the time above 10,000 ft Required cabin crew All the time above 13,000 ft ; and any period of more than 30 min between 10,000 and 13,000 ft 100 % of passengersAll the time above 13,000 ft 10 % of passengersAfter 30 min between 10,000 and 13,000 ft
Oxygen equipment is required for any flight above 10,000 ft. With no fixed system, portable sets are carried.
Chapter 18 · Oxygen Systems
9
e-books by eatpl.in · © 2026 · Do not copy or distribute
Unpressurised aircraft are simpler, because the cabin altitude is the aircraft altitude, so the rules use the pressure altitude flown. Any aeroplane intended to fly above ten thousand feet must have equipment to store and dispense oxygen; if there is no fixed installation, portable sets are carried. The flight crew on duty must have oxygen continuously, all the time above ten thousand feet. The required cabin crew need it all the time above thirteen thousand feet, and for any period of more than thirty minutes between ten and thirteen thousand. All passengers need oxygen above thirteen thousand feet, and ten per cent of them need it after thirty minutes between ten and thirteen thousand. So for the exam: flight crew in an unpressurised aircraft, above ten thousand feet; one hundred per cent of the passengers, above thirteen thousand feet.
Part 2 · The rules
How many masks? Above 25,000 ft (or unable to descend to 13,000 ft in 4 min , newer types): automatically presented masks for every occupant, wherever seated Total dispensing units and outlets must exceed the seats by at least 10 % , spread evenly Based on seats fitted , not passengers carried or the type's maximum Each toilet has masks (usually 2); spare outlets or portables for cabin crew Worked: 180 seats → 198 ; 200 seats fitted → 220 Masks / outlets = seats + at least 10 % extra masks: spread through the cabin, toilets, galleys 180 seats (3 + 3) 180 × 1.1 = 198 masks 200 seats fitted (type certificated for 250, 180 aboard) based on seats fitted: 200 × 1.1 = 220
Chapter 18 · Oxygen Systems
10
e-books by eatpl.in · © 2026 · Do not copy or distribute
Aeroplanes flying above twenty five thousand feet, and newer types that cannot get down to thirteen thousand feet within four minutes, must have oxygen masks that are presented automatically to every occupant, wherever they are sitting. And there must be more of them than seats: the total number of dispensing units and outlets must exceed the number of seats by at least ten per cent, with the extras spread evenly through the cabin, so that people who are standing in the aisle, in a galley or in a toilet can reach one. Each toilet usually has two masks. Let us do the sums. An aircraft fitted with a hundred and eighty seats needs a hundred and eighty times one point one, which is a hundred and ninety eight masks. If an aircraft is fitted with two hundred seats, it needs two hundred and twenty, even if the type is certificated for two hundred and fifty and only a hundred and eighty passengers are aboard.
Part 2 · The rules
First-aid (therapeutic) oxygen For passengers who, for medical reasons , need oxygen after a depressurisation, or are unwell Required: pressurised aeroplane above 25,000 ft when a cabin crew member is carried Undiluted oxygen for 2 % of passengers (at least one) for the rest of the flight with cabin altitude 8,000–15,000 ftAverage 3 L/min ; units deliver 4 L/min , reducible to 2; at least two dispensing units Flow rates are given in litres per minute first-aid oxygen undiluted, portable Who pressurised, above 25,000 ft, cabin crew carried For medical need, e.g. after a decompression How much 2 % of passengers (min 1), cabin 8,000 – 15,000 ft Flow 3 L/min average; 4 L/min reducible to 2; 2+ units Therapeutic use: passengers whose medical condition needs it Supplemental oxygen is the decompression supply
Chapter 18 · Oxygen Systems
11
e-books by eatpl.in · © 2026 · Do not copy or distribute
First-aid oxygen, also called therapeutic oxygen, is different from supplemental oxygen. It is for passengers whose medical condition means they need oxygen, either because they are unwell or because, for physiological reasons, they still need it after a depressurisation once the cabin is back at a breathable altitude. It is not for troublesome passengers or only for heart attacks; it is for anyone whose medical condition requires it. A pressurised aeroplane flying above twenty five thousand feet with cabin crew must carry undiluted first-aid oxygen for at least two per cent of the passengers, and never for fewer than one person, for the rest of the flight after a depressurisation when the cabin altitude is between eight and fifteen thousand feet. The quantity is based on an average flow of three litres per minute per person, and the equipment must give four litres per minute, reducible to two, from at least two dispensing units.
Part 3 · Crew systems
Storing oxygen Three forms: gaseous (high-pressure cylinders), chemical generators, liquid (not used in civil transport) Flight crew: gaseous oxygen; passengers: gaseous or chemical Cylinders charged to about 1800 psi ; contents shown as pressure on the flight deck Colours: American green ; British black with a white neck Shut-off valve on each cylinder so it can be removed for maintenanceGaseous high-pressure cylinders, about 1800 psi crew (and some passenger) systems Chemical sodium chlorate generators passenger and cabin crew masks Liquid very cold, needs special handling military; not used in civil transport Cylinder colours (exam) American: green British: black, white neck (shoulder) Each cylinder has a shut-off valve so it can be removed
Chapter 18 · Oxygen Systems
12
e-books by eatpl.in · © 2026 · Do not copy or distribute
Oxygen can be carried in three forms. Gaseous oxygen is stored in high-pressure cylinders. Chemical oxygen is locked up in solid generators that release it when fired. Liquid oxygen is very compact but extremely cold and needs special handling, so it is used in military aircraft but not in civil transport. The flight crew system always uses gaseous oxygen. Passenger systems may be gaseous or chemical. The cylinders are charged to about eighteen hundred p s i, and since the gas obeys the gas laws, the contents are shown as a pressure on a gauge on the flight deck. Remember the colours for the exam: American oxygen cylinders are green, while British ones are black with a white neck, or shoulder. Each cylinder has a shut-off valve, so that it can be isolated and removed for maintenance or replacement.
Part 3 · Crew systems
Over-pressure: the bursting disc If the cylinder pressure rises too far (for example from heat ), a bursting (safety) disc ruptures The oxygen is discharged overboard , not into the aircraft It blows out a green discharge indicator disc on the fuselage skin beside the bottles Green disc missing on the walk-round → cylinder has vented Not a relief valve or thermostat: a one-shot disc bursting disc green disc skin Over-pressure (e.g. heat): disc bursts, oxygen vents overboard and blows out the green indicator: seen on the walk-round
Chapter 18 · Oxygen Systems
13
e-books by eatpl.in · © 2026 · Do not copy or distribute
An oxygen cylinder could be dangerous if its pressure rose too far, for example if it were heated by a fire nearby. So each installation has a safety device, a bursting disc, which ruptures at a set pressure. Watch the model. Here is the cylinder with its gauge showing about eighteen hundred p s i on the flight deck. The bursting disc is piped to the fuselage skin, where it ends at a small green discharge indicator disc, close to the oxygen bottles. If the pressure becomes too high, the disc bursts, the oxygen is discharged overboard, and the green indicator is blown out. During the walk-round the pilot checks that the green disc is in place; if it is missing, the cylinder has vented. So an over-pressurised fixed oxygen system does not explode, and does not dump oxygen into the cabin: it discharges its excess overboard.
Part 3 · Crew and passenger systems
The continuous-flow system cylinder 1800 psi shut-off and line valves PRV pressure reducing valve: 80 – 100 psi calibrated orifice masks: flow starts when plugged in, or when a drop-out mask is pulled Used for passengers (and the crew of some smaller aircraft). Oxygen flows all the time a mask is connected.
Chapter 18 · Oxygen Systems
14
e-books by eatpl.in · © 2026 · Do not copy or distribute
The continuous flow system is the simplest. When the shut-off valve on the cylinder and the line valve are opened, high-pressure oxygen at about eighteen hundred p s i flows to a pressure reducing valve, which cuts it down to eighty to a hundred p s i for the supply line. At each mask outlet a calibrated orifice reduces it further and sets the flow, so oxygen is delivered steadily at the right rate for breathing. The masks may be the plug-in type, where oxygen flows only when the mask is plugged into its socket, or the drop-out type, where the masks are presented automatically after a pressurisation failure and the flow begins when the passenger pulls the mask down. Either way, once the mask is connected, oxygen flows continuously, whether the user is breathing in or out. That is simple, but it wastes oxygen, which is why the crew use a demand system.
Part 3 · Crew systems
Regulators and flow indicators Continuous-flow regulators: hand adjustable (crew) or automatic (passengers) Hand adjustable: pressure gauge, flow indicator and a knob set to the cabin altitude Most flow indicators show only that oxygen is flowing They do not show how much, or whether the user gets enough Satisfactory operation of the system is shown by the flow indicators psi pressure gauge flow indicator manual flow knob (set to cabin altitude) A flow indicator (blinker) shows only that oxygen is FLOWING through the regulator not how much, nor whether the user gets enough → it is the indication of satisfactory operation
Chapter 18 · Oxygen Systems
15
e-books by eatpl.in · © 2026 · Do not copy or distribute
Continuous flow regulators come in two kinds: hand adjustable, usually for the crew of smaller aircraft, and automatic, usually for passengers. A hand adjustable regulator has a pressure gauge showing the cylinder pressure in p s i, a flow indicator, and a manual knob. The user turns the knob until the flow indicator, which may be calibrated in cabin altitude, matches the cabin altitude. But be careful what a flow indicator tells you. Most of them, including the blinker type on crew regulators, only show that oxygen is flowing through the regulator. They do not show exactly how much is flowing, and they do not prove that the user is getting enough. Even so, in the exam, the satisfactory operation of the oxygen system is indicated by the flow indicators, not by the pressure gauges, and not by the absence of symptoms.
Part 3 · Crew systems
The diluter-demand regulator Flight crew system, separate from the passenger system; one regulator per crew member (and observer) Supplied with gaseous oxygen from the crew cylinder Oxygen flows only on demand : inhaling moves the diaphragm and opens the demand valve Diluted with flight deck air (air from the packs ) through an air inletAn aneroid sets the mix: mostly air low down, more oxygen as the cabin climbs O2 supply cabin air via air inlet demand valve diaphragm air metering aneroid to mask Inhale → suction on the diaphragm → demand valve opens Aneroid: lots of air low down, more oxygen higher up One regulator for each crew member Oxygen only flows while the user breathes in: economical
Chapter 18 · Oxygen Systems
16
e-books by eatpl.in · © 2026 · Do not copy or distribute
Most aircraft give the flight crew a diluter-demand system, separate from and in addition to the passenger system, fed with gaseous oxygen from the crew cylinder. There is a regulator for each crew member, including the observer's seat. It works on demand. When you breathe in, you create a small suction in the mask that is felt by a diaphragm, which opens the demand valve, so oxygen flows only while you inhale. That saves a great deal of oxygen. It is also diluted. On its way to the mask, the oxygen is mixed with air from the flight deck, which of course came from the air conditioning packs, drawn in through an air inlet. An aneroid capsule controls the air metering valve, giving a high proportion of air at low cabin altitudes and more and more oxygen as the cabin altitude rises.
Part 3 · Crew systems
From diluted to 100 % oxygen In NORMAL the oxygen share rises with cabin altitude The regulator gives 100 % oxygen from about 32,000 – 34,000 ft cabin altitude Computed: 100 % at about 34,000 ft keeps sea-level alveolar oxygen Above that, even 100 % falls short: pressure is needed Exam answers: 32,000 ft or 34,000 ft, whichever is offered 0 % 25 % 50 % 75 % 100 % 0 10k 20k 30k 40k cabin altitude (ft) oxygen in the breathed gas plain air: 21 % at every height 100 % at about 34,000 ft oxygen % needed for sea-level alveolar oxygen NORMAL: regulator reaches 100 % at about 32,000 – 34,000 ft
Chapter 18 · Oxygen Systems
17
e-books by eatpl.in · © 2026 · Do not copy or distribute
How much oxygen does the diluter mix in? The green curve is computed from the alveolar gas equation: it is the percentage of oxygen you would need to breathe to keep the same oxygen pressure in your lungs as at sea level. At sea level it is just air, twenty one per cent. At ten thousand feet you need about thirty one per cent, at twenty five thousand about sixty two per cent, and the curve reaches one hundred per cent at about thirty four thousand feet. The regulator's normal schedule follows the same idea, giving more oxygen as the cabin climbs, and it reaches one hundred per cent at a cabin altitude of about thirty two to thirty four thousand feet. Both figures appear in exam questions, so pick whichever is offered. Above that height even pure oxygen is not enough on its own, which is why the crew system can also supply oxygen under pressure.
Part 3 · Crew systems
Crew regulator selections Selection What you get Use NORMAL (N)Diluted oxygen on demand: select NORMAL and breathe in Routine use, decompression at moderate height 100 % 100 % oxygen at any altitude; air inlet shut , so no fumes drawn in Smoke or fumes in the cockpitEMERGENCY 100 % oxygen at positive pressure , flowing continuously Smoke leaking into the mask or goggles; very high cabin altitude TEST 100 % oxygen at high positive pressure Check mask fit and leaks before flight
Smoke in the cockpit: mask on, 100 % ; add EMERGENCY (overpressure) if smoke gets into the mask or goggles.
Chapter 18 · Oxygen Systems
18
e-books by eatpl.in · © 2026 · Do not copy or distribute
The crew regulator has a few selections, and the exam loves them. In normal, you get diluted oxygen on demand: you select normal and breathe in through the mask. Selecting one hundred per cent gives pure oxygen at any altitude, because the air inlet is closed, and that is what you want if there is smoke or fumes on the flight deck, since no flight deck air can be drawn into the mask. Selecting emergency gives one hundred per cent oxygen at a positive pressure, flowing steadily, so that any leak around the mask or goggles blows outwards and smoke cannot get in; it is used if smoke is getting into the mask, and at very high cabin altitudes. Finally, test supplies oxygen at a high positive pressure so that you can check the mask fit and look for leaks before flight. Smoke drill: mask on, one hundred per cent, and emergency if needed.
Part 3 · Crew systems
The quick-donning crew mask Mask and regulator combined, stowed in a box at each crew station Required for flight crew above 25,000 ft Squeeze the red grips : the harness inflates ; let go and it grips the head Control: N / 100 % PUSH ; EMERGENCY knob for steady positive pressure; PRESS TO TEST Box doors closed: a shut-off valve stops the flow; built-in mic; goggle ventilation red grips N / 100% EMERGENCY PRESS TO TEST flow indicator harness inflates while the grips are held Quick-donning: on with one hand in about 5 seconds Required for flight crew above 25,000 ft Squeeze grips: harness inflates; release: it grips the head Stowage box shut-off: no flow until the doors open Mic built in; goggle vent clears misting
Chapter 18 · Oxygen Systems
19
e-books by eatpl.in · © 2026 · Do not copy or distribute
Above twenty five thousand feet, where the time of useful consciousness is a few minutes or less, the flight crew must have quick-donning masks. Each one combines the mask and the regulator and sits in a stowage box at the crew station, with the regulator controls showing through the doors. To put it on, you grasp the two red grips between thumb and forefinger and pull the mask out. Squeezing the grips inflates the harness so it slips easily over your head; release the grips and the harness deflates and holds the mask firmly, whatever your head size, all with one hand in a few seconds. On the front is the normal or one hundred per cent push control, and an emergency knob that gives a steady flow at positive pressure, also marked press to test. With the box closed, a shut-off valve stops the flow. The mask has a microphone, and a vent can clear misting smoke goggles.
Part 4 · Passenger systems
Passenger masks: presented, pulled, breathing Masks stowed in the passenger service units (PSU) above the seats Doors open automatically (barometric) at 14,000 ft cabin altitude, or manually from the flight deck at any altitude Release: electrical for chemical generators, pneumatic for gaseous systems Masks drop to the half-hung position; pulling one starts its flow Continuous flow into a reservoir bag, diluted with cabin air door opens half-hung: pull to start flow Auto: barometric release at 14,000 ft cabin altitude Manual: from the flight deck at any altitude Release: electrical (chemical) or pneumatic (gaseous) Pull mask: fires generator / opens check valve Continuous flow into a bag; diluted with cabin air
Chapter 18 · Oxygen Systems
20
e-books by eatpl.in · © 2026 · Do not copy or distribute
The passenger masks are stowed in the passenger service unit above each seat row. Watch the cabin altitude gauge climb after a pressurisation failure. When it reaches fourteen thousand feet, a barometric switch unlatches the doors automatically. The crew can also open them manually from the flight deck at any altitude below that, for example if fumes need clearing. On a chemical system the release is electrical; on a gaseous system it is pneumatic, using oxygen pressure. The doors fall open and the masks drop to the half-hung position, ready to use. They are not handed out by the cabin crew, and nobody has to grab them from a locker. Pulling a mask towards your face starts its flow, either by opening a check valve on a gaseous system or by firing the chemical generator. The flow is continuous, into a reservoir bag, and the oxygen is diluted with cabin air drawn in through valves in the mask.
Part 4 · Passenger systems
The chemical oxygen generator Sodium chlorate and iron core: NaClO3 + Fe → NaCl + FeO + O2 Fired by pulling the mask: a lanyard and firing pin (percussion cap) or an electrical igniter Filter cleans and cools the oxygen (to within 10 °C of cabin temperature); relief valve 50 psi; normal flow pressure 10 psiLasts at least 15 min (some 22 min); cannot be stopped once started Surface up to 232 °C ; heat tape turns black when used; 10-year life 0 5 10 15 minutes after firing oxygen flow most flow at the start, when the cabin is highest ends ≥ 15 min Cannot be stopped · up to 232 °C · tape turns black when used · 10-year life
Chapter 18 · Oxygen Systems
21
e-books by eatpl.in · © 2026 · Do not copy or distribute
Most airliners use chemical oxygen generators for the passengers, cabin attendants and toilets. Each is a light, self-contained can with a core of sodium chlorate and iron. Pulling a mask pulls a lanyard that releases a firing pin onto a percussion cap; on some systems the igniter is electrical. The core then burns, and the sodium chlorate releases its oxygen as the reaction runs. The core is shaped to give the most oxygen at the start, when the cabin is highest. A filter removes contaminants and cools the gas to no more than ten degrees above cabin temperature, and a relief valve stops the internal pressure exceeding fifty p s i; normal flow pressure is about ten. A generator lasts at least fifteen minutes, enough for the emergency descent, and some last twenty two. Once started, it cannot be stopped. The case can reach two hundred and thirty two degrees, and a heat-sensitive strip turns black to show it has been used.
Part 4 · Passenger systems
Chemical generators: pros, cons and precautions Typical use: passengers (and cabin crew); the flight crew keep a gaseous system.
Advantages Cheap and light ; little maintenance ; ready for use after years on standby; no high-pressure piping through the cabin.
Disadvantages Cannot be switched off ; fixed duration (about 15 min); very hot ; a fire hazard if fired by accident or in a fire.
Not better oxygen The oxygen is no purer than stored gas, and the system is not hazard-free .
Precautions No smoking near oxygen in use; no oil or grease on any oxygen part; treat a fallen mask as a used generator.
Chapter 18 · Oxygen Systems
22
e-books by eatpl.in · © 2026 · Do not copy or distribute
Chemical generators have clear advantages. They are cheap and light, they need very little maintenance, and they sit ready for immediate use for years on standby, up to their ten-year life. They also avoid running high-pressure oxygen pipes through the cabin. But there are disadvantages. Once fired, a generator cannot be switched off, it lasts only its set time of about fifteen minutes, it gets very hot, and a generator fired by accident, or in a fire, is a serious fire hazard. Several accidents have been caused by expired generators carried as cargo. They do not provide purer oxygen than stored gas, and they are certainly not hazard-free. So where they are used, no smoking is allowed near oxygen in use, no oil or grease may touch the system, and a mask that falls from its stowage is not ignored. For these reasons generators are used for the passengers, while the flight crew keep gaseous oxygen.
Part 4 · Passenger systems
Oxygen masks and smoke Oxygen masks are provided for decompression and, for the crew, protection from smoke and fumes Crew: 100 % shuts out flight deck air; EMERGENCY adds overpressure Passenger masks dilute with cabin air , so they give only limited protection from smoke But oxygen can be given through them in a smoky cabin (crew drop them manually) A passenger system supplying 100 % oxygen can be used in smoke; not via the air conditioning Crew masks diluter-demand 100 %: air inlet shut, no smoke drawn in EMERGENCY: 100 % at positive pressure + smoke goggles protect Passenger masks continuous flow bag + cabin air drawn in: diluted oxygen crew can drop them at any altitude not a smoke hood limited Exam logic Oxygen masks serve both decompression and smoke (crew) Smoky cabin: oxygen CAN be given through the passenger masks A 100 % passenger system CAN be used in smoke
Chapter 18 · Oxygen Systems
23
e-books by eatpl.in · © 2026 · Do not copy or distribute
What about smoke? Oxygen masks serve two purposes: they provide oxygen after a decompression, and, for the crew, they protect against smoke and fumes. A crew mask on one hundred per cent shuts out the flight deck air, and emergency adds an overpressure so that smoke cannot leak in. Passenger masks are different. They are continuous flow masks with a bag, and they draw in cabin air to dilute the oxygen, so in a smoky cabin they give only limited protection. Even so, if the cabin fills with smoke, oxygen can be supplied to passengers through their masks, because the crew can present them manually at any altitude; it cannot be supplied through the air conditioning. And if a passenger system supplies one hundred per cent oxygen, with no cabin air drawn in, then yes, it can be used in a smoke-filled cabin. The real smoke protection for crew who must move about is the smoke hood.
Part 5 · Portable oxygen
Portable oxygen sets First-aid and sustaining cylinders at points in the cabin: usually 120 litres at 1800 psi , in a bag with straps Two flows: NORMAL 2 L/min and HIGH 4 L/min 120 L lasts 60 min on NORMAL, 30 min on HIGH Larger 310 L bottles with a four-way manifold for several users Crew use them to move about the cabin after a decompression
120 L · 1800 psi
NORMAL 2 L/min 120 ÷ 2 = 60 min first aid / sustaining
HIGH 4 L/min 120 ÷ 4 = 30 min more distress
310 L bottle: 155 min at 2 L/min, 77 min at 4 L/min
Chapter 18 · Oxygen Systems
24
e-books by eatpl.in · © 2026 · Do not copy or distribute
Portable oxygen sets are stowed at points around the cabin for first aid and to sustain people who need oxygen. A typical set is a cylinder holding a hundred and twenty litres of oxygen at eighteen hundred p s i, in a carrying bag with straps. It usually has two flow settings, normal and high, which give two and four litres per minute. The arithmetic is simple. At two litres per minute, a hundred and twenty litres lasts sixty minutes; at four litres per minute, it lasts thirty minutes. Larger three hundred and ten litre bottles with a four-way manifold can supply several people at once. The cabin crew also use standard portable bottles to move about the cabin after a decompression, when they cannot stay plugged into a seat outlet. For smoke, though, they need a full-face mask or a smoke hood.
Part 5 · Smoke protection
Protective breathing equipment and smoke hoods PBE protects the eyes, nose and mouth from smoke and toxic fumes , with breathing gas for at least 15 min At each flight crew station, each required cabin crew station, and beside the hand extinguishers (outside cargo holds) Smoke hood : covers the whole head , rubber neck seal , continuous oxygen from a chemical generatorStarted by a pull cord (toggle); expired when breathing gets harder For trained crew only ; must not prevent communication visor generator rubber neck seal start cord whole head covered continuous oxygen, ≥ 15 min crew only (training needed) Expiry: breathing becomes harder → leave smoke area, remove hood
Chapter 18 · Oxygen Systems
25
e-books by eatpl.in · © 2026 · Do not copy or distribute
Protective breathing equipment, or P B E, is what the crew wear to fight a fire. It must protect the eyes, nose and mouth from smoke and toxic gases and supply breathing gas for at least fifteen minutes. On the flight deck this can be the crew oxygen mask with smoke goggles. Elsewhere, P B E is stowed at each required cabin crew station, and beside each hand fire extinguisher, outside the entrance of any cargo compartment. It must not stop the wearer communicating. The usual cabin P B E is the smoke hood. It covers the whole head, with a clear visor and a rubber neck seal, and a self-contained chemical generator supplies a continuous flow of oxygen once started by pulling the start cord. Check before use that the cord is intact. When the oxygen runs out, breathing becomes harder: time to leave the smoke and remove the hood. Smoke hoods need training, so they are for crew only.
Part 6 · Safety
Safety precautions with oxygen Oxygen does not burn but supports combustion : everything burns fiercer; no smoking No oil or grease : risk of spontaneous combustion; tools and clothing cleanOnly aviators' breathing oxygen : moisture corrodes and can freeze valves Oxygen is heavier than air : ventilate; it pools in pits and bilges Threads: graphite (approved lubricants only); leak test with acid-free soap and distilled water No oil or grease can ignite spontaneously in oxygen No smoking, no flames everything burns fiercer Dry oxygen only aviators' breathing oxygen; moisture corrodes, freezes valves Ventilate heavier than air: pools in pits, bilges Threads graphite or approved tape only Leak test acid-free soap + distilled water
Chapter 18 · Oxygen Systems
26
e-books by eatpl.in · © 2026 · Do not copy or distribute
Oxygen is not flammable itself, and it is heavier than air, but it supports combustion as well as life. Anything that can burn burns far more fiercely in an oxygen-rich atmosphere, so smoking is banned, and all combustible material is removed from areas where oxygen is being serviced. Oil and grease are particularly dangerous: in contact with oxygen under pressure they can react violently and ignite by themselves, so tools, hands and clothing must be free of them. Moisture is another enemy: it causes corrosion, it can freeze in valves as the gas expands, and it makes the oxygen smell bad, so only oxygen approved for aviation breathing is used. Because it is heavier than air, oxygen collects in low places such as servicing pits and bilges, so the area must be well ventilated. Only approved lubricants, such as graphite, go on threads, and leaks are found with acid-free soap and distilled water.
Physiology O2 stays 21 % ; pressure falls. TUC 25,000 ft ≈ 3 min , 30,000 ft 90–45 s, 40,000 ft ≈ 20 s . 10,000 ft: max without O2 .
Rules Pressurised pax: 100 % >15,000 , 30 % 14–15,000, 10 % 10–14,000. Unpressurised: crew >10,000, all pax >13,000. Masks = seats + 10 % .
Crew Gaseous, 1800 psi ; diluter-demand: 100 % at about 32–34,000 ft ; 100 % for smoke; EMERGENCY = positive pressure. Quick-don >25,000 ft.
Passengers Masks drop at 14,000 ft to half-hung; pull to start. Generators: NaClO3 + Fe, 15 min , can't stop, 232 °C.
Portable / PBE 120 L: 60 min at 2 L/min, 30 min at 4. First-aid O2 2 % of pax. PBE / smoke hood 15 min , pull cord.
Safety Bursting disc → overboard, green indicator. No oil or grease ; graphite; acid-free soap + distilled water. US green, UK black/white.
Chapter 18 · Oxygen Systems
27
e-books by eatpl.in · © 2026 · Do not copy or distribute
Let us sum up. The air is always about twenty one per cent oxygen, but its pressure falls, and at height you have little time: about three minutes at twenty five thousand feet and about twenty seconds at forty thousand. Ten thousand feet is the limit without oxygen. In a pressurised aircraft all passengers need oxygen above fifteen thousand feet cabin altitude, and the masks must exceed the seats by ten per cent. The crew breathe stored gas through a diluter-demand regulator that reaches one hundred per cent at about thirty two to thirty four thousand feet; one hundred per cent is the smoke setting, and emergency adds positive pressure. Passenger masks drop at fourteen thousand feet and chemical generators run for fifteen minutes and cannot be stopped. Portable bottles last sixty minutes at two litres per minute, smoke hoods at least fifteen minutes, and no oil or grease may ever touch oxygen equipment.