Electrics · Chapter 15
AC Motors How AC sets up a rotating magnetic field, and how synchronous and induction motors use it: speed, slip, starting, reversing and what happens when a phase fails.
STATOR FIELD TURNS · ROTOR FOLLOWS © 2026 eatpl.in. For the personal study of eatpl.in students only. Do not copy or distribute.
e-books by eatpl.in · © 2026 · Do not copy or distribute
Welcome to chapter fifteen, A C motors. On a modern airliner most of the motors, the fuel pumps, the electric hydraulic pumps, the fans and the gyros, run straight from the one hundred and fifteen volt, four hundred hertz AC supply. They have no commutator to arc at altitude and often no brushes at all. In this lesson we will see how three AC currents, one hundred and twenty degrees apart, make a magnetic field that spins round the stator, and how two kinds of rotor follow it. The synchronous motor locks onto the field and runs at exactly its speed; the induction motor is dragged round a little slower, and that small difference, called slip, is the key to how it works. We will finish with starting, reversing, single-phase motors and phase failure, all favourite exam topics.
Roadmap
One rotating field, two kinds of rotor AC in the stator single or three-phase Rotating field speed set by frequency Synchronous DC rotor locks on: exactly Ns Induction cage rotor: Ns minus slip 1 · Why AC motors No commutator arcing; speed fixed by the supply frequency.
2 · Rotating field How three currents 120° apart make a field that turns.
3 · Synchronous DC-fed rotor locks to the field; Ns = 120 f / p; the rpm indicator.
4 · Induction Squirrel cage, slip, reversing, single-phase starting, phase failure.
Chapter 15 · AC Motors
2
e-books by eatpl.in · © 2026 · Do not copy or distribute
Here is the plan for this chapter. We start with why aircraft prefer AC motors to DC motors. Then comes the key idea of the whole chapter: the rotating magnetic field. Feed AC into the stator windings and you get a magnetic field that turns round inside the motor at a speed set by the supply frequency. Everything else follows from that. If the rotor is a magnet, fed with DC, it locks onto the field and turns at exactly the same speed: that is the synchronous motor, and we will see how it is used in the engine rpm indicator. If the rotor is a simple cage of copper bars with no supply at all, the field induces currents in it and drags it round, a little slower than the field: that is the induction motor, the workhorse of the aircraft. We finish with slip, reversing, single-phase starting and what happens when a phase fails.
Part 1 · Why AC motors
Why aircraft prefer AC motors AC motors can do most jobs of DC motors and are less troublesome DC motors suffer from commutation problems: arcing , worse at high altitude DC brushes run hot, stick in their holders , resistance rises, even to open circuit Synchronous AC motors still have brushes, but only carry low-current DC on slip rings AC motor speed is set by the supply frequency : ideal for constant-speed jobs Run from single-phase or multi-phase supplies DC motor AC induction motor commutator + brushes arcing, worse at altitude brushes stick, wear, can open-circuit no commutator, no brushes rotor not connected to anything simple, robust, reliable
Chapter 15 · AC Motors
3
e-books by eatpl.in · © 2026 · Do not copy or distribute
Why do aircraft use AC motors wherever they can? Alternating current motors can do almost every job a DC motor does, and they are much less troublesome. A DC motor needs a commutator and brushes to keep reversing the current in its armature. Commutation causes arcing, and at high altitude, where the air is thin and dry, the arcing and brush wear get much worse. The brushes also run hot, can stick in their holders, and as the contact resistance rises the motor may end up open-circuit and stop. An induction motor has no commutator and no brushes at all. A synchronous motor does have brushes, but they only carry a small DC current to its rotor through smooth slip rings, which is far less troublesome. A further advantage is that an AC motor’s speed is set by the supply frequency, which makes it ideal for constant-speed work, and AC motors can run from single-phase or multi-phase supplies.
Part 2 · The key idea
How three currents make a rotating field 0° 60° 120° 180° A B C phase currents, 120° apart one cycle of the supply → 0° 60° 120° 180° Resultant field: same strength (1.5 × one phase), turning one pole-pair per cycle coil axes A (up), B, C at 120°; arrow = sum of the three coil fields Each coil’s field only pulses along its own axis, but the sum of the three is a field of constant strength that rotates .
Chapter 15 · AC Motors
4
e-books by eatpl.in · © 2026 · Do not copy or distribute
This is the central idea of every AC motor. The stator has three sets of coils, A, B and C, spaced one hundred and twenty degrees apart round the frame, and each is fed from one phase of the supply, so their currents are also one hundred and twenty degrees apart in time. Each coil on its own only makes a field that pulses back and forth along its own axis. But add the three together at any instant and something remarkable happens. At nought degrees, phase A is at its peak and the resultant points along coil A. Sixty degrees later in the cycle, the resultant has turned sixty degrees. At one hundred and twenty degrees it has turned one hundred and twenty, and so on. Its strength never changes: it is always one and a half times the peak of one phase. So three stationary coils produce a field of constant strength that rotates steadily, once for every cycle in a two-pole winding.
The rotating field
A magnet in the field turns with it AC applied to the stator sets up a rotating magnetic field True for single and multi-phase motors (single-phase needs help to start) The field turns at synchronous speed , fixed by the frequency A magnet placed in the field would turn with it Every AC motor uses this field to drag the rotor round A B C the field turns; a magnet in the middle turns with it
Chapter 15 · AC Motors
5
e-books by eatpl.in · © 2026 · Do not copy or distribute
Here is the same idea in three dimensions. The stator is the fixed outer frame, carrying the three pairs of coils, one pair for each phase, colour coded A, B and C. When three-phase AC is applied, the resultant field, the blue arrow, rotates steadily round the inside of the stator at a speed set by the supply frequency. We call this the synchronous speed. Now imagine hanging a bar magnet in the middle. Its poles are attracted by the rotating field, so the magnet turns with it, at exactly the same speed. Whether a motor is single-phase or multi-phase, the principle of operation is the same: alternating current in the stator produces a rotating magnetic field, and that field causes the rotor to turn. The only question is what kind of rotor we put in the middle, and that gives us the two families of AC motor.
Two families
Synchronous or induction? Synchronous motor AC to the stator, DC to the rotor . Basically an alternator run as a motor. The rotor is a magnet that locks onto the field and turns at exactly synchronous speed . Not self-starting.
Induction motor AC to the stator, no supply to the rotor . The field induces AC in a squirrel-cage rotor, which is dragged round slightly slower than the field. Simple, robust, cheap.
Chapter 15 · AC Motors
6
e-books by eatpl.in · © 2026 · Do not copy or distribute
Most aircraft motors fall into one of two families. The synchronous motor is basically an alternator run as a motor. Alternating current is applied to the stator, and the rotor is fed with direct current, so it becomes an electromagnet. That magnet locks onto the rotating field and turns at exactly the synchronous speed, no faster and no slower. Its weakness is that it cannot start by itself. The induction motor also has AC on the stator, but its rotor has no power source at all. The rotating field induces alternating currents in the rotor, those currents make their own magnetism, and the rotor is dragged round, always a little slower than the field. Because the rotor needs no connection, the induction motor is simple, robust and cheap, and it is by far the most common type. Remember the one-line test: DC in the rotor means synchronous; nothing in the rotor means induction.
Part 3 · Synchronous motor
The synchronous motor Built like a rotating-field alternator Three-phase AC to the stator makes the rotating fieldRotor fed with DC through slip rings : it acts as a magnet The rotor lines up with the stator field and turns with it Speed is exactly synchronous : it does not change with load S N + − DC slip rings rotor locks to the field: speed = synchronous speed
Chapter 15 · AC Motors
7
e-books by eatpl.in · © 2026 · Do not copy or distribute
The synchronous motor gets its name because its rotor turns in step, or in synchronism, with the rotating field of the stator. In construction it is basically the same as a rotating-field alternator. The stator carries the three-phase windings, usually fed with three-phase AC, which set up the rotating field. The rotor is an electromagnet: a winding on an iron pole piece, fed with a fairly small DC current through slip rings and brushes. Watch what happens once the rotor is up to speed: it locks onto the rotating field and turns at exactly the same speed, lining up with it like a compass needle following a magnet. When load is added, the rotor drops back a few degrees behind the field, but it does not slow down; it keeps exactly the synchronous speed until it is overloaded and falls out of step. So its speed depends only on the supply frequency and the number of poles.
Synchronous speed
Speed is set by frequency and poles Synchronous speed Ns = 120 × f ÷ p rpm, where f is the supply frequency in hertz and p is the number of poles.
Poles (p) Pole pairs Ns at 400 Hz Ns at 50 Hz (for comparison) 2 1 24 000 rpm 3 000 rpm 4 2 12 000 rpm 1 500 rpm 6 3 8 000 rpm 1 000 rpm 8 4 6 000 rpm 750 rpm
A synchronous motor runs at the same speed as the alternator supplying it, if both have the same number of poles. Constant frequency gives constant speed; double the frequency and the speed doubles.
Chapter 15 · AC Motors
8
e-books by eatpl.in · © 2026 · Do not copy or distribute
How fast does the field turn? In one cycle, the field moves on by one pair of poles. So the synchronous speed in revolutions per minute is one hundred and twenty times the frequency, divided by the number of poles. On the aircraft’s four hundred hertz supply, a two-pole motor turns at twenty-four thousand r p m, and a four-pole motor at twelve thousand r p m. That four-pole example is a classic exam figure. Six poles give eight thousand, and eight poles give six thousand. Compare a fifty hertz mains supply, where a four-pole motor turns at only fifteen hundred r p m; the high aircraft frequency is one reason aircraft motors can be so small and light. Notice too that a synchronous motor turns at exactly the same speed as the alternator feeding it, if they have the same number of poles. With a constant-frequency supply, the speed is constant. Change the frequency, and the speed follows it exactly.
Starting
Why a synchronous motor cannot start itself At rest, the field sweeps past the rotor hundreds of times a second The rotor is pulled one way, then the other: average torque zero So a synchronous motor is not self-starting Fix: add induction windings to the rotor to bring it up to speed Near synchronous speed the DC-fed rotor pulls into step Rotor at rest: torque as the field sweeps past average torque = 0 time (the field passes many times each second) Cure: induction (damper) windings on the rotor start it like an induction motor, accelerate to just below synchronous speed, then the DC-excited rotor pulls into step
Chapter 15 · AC Motors
9
e-books by eatpl.in · © 2026 · Do not copy or distribute
The synchronous motor has one big disadvantage: it is not self-starting. Think about the rotor sitting still while the field whirls round it hundreds of times a second. As a north pole of the field sweeps towards the rotor’s south pole, it pulls the rotor one way. A moment later it has swept past and pulls it back the other way. The rotor is heavy and cannot respond that quickly, so the torque swings back and forth and averages out to zero. The rotor just sits and vibrates. The cure is to add some induction windings to the rotor, rather like the bars of a squirrel cage. These let the motor start as an induction motor and accelerate to just below synchronous speed. At that point the field is passing the rotor only slowly, and the magnetism of the DC-fed rotor can pull it into step, after which it runs at exactly synchronous speed.
Application
The engine rpm indicator A small three-phase tacho-generator is driven by the engine Its output frequency is proportional to engine rpm In the indicator, a synchronous motor follows that frequency It spins a permanent magnet inside a drag cup ; eddy currents drag the cup against a hairspring Pointer deflection ∝ rpm; reading depends on frequency, not voltage tacho- generator 3-phase engine drive frequency ∝ rpm synchronous motor PM drag cup % RPM The magnet spins with the motor; eddy currents drag the cup round against a hairspring: more rpm, more drag, more deflection. Reading depends on frequency, not on voltage.
Chapter 15 · AC Motors
10
e-books by eatpl.in · © 2026 · Do not copy or distribute
A neat use of the synchronous motor is the engine speed indicator. A small three-phase alternator, called a tacho-generator, is driven by the engine, so the frequency of its output is directly proportional to engine speed. Three wires carry that output to the indicator on the panel, where it drives a synchronous motor. The motor therefore turns at a speed that exactly follows the engine. It spins a permanent magnet inside a light metal drag cup. The spinning magnet induces eddy currents in the cup, and these drag the cup round after it, against the pull of a hairspring. The faster the motor, the greater the drag, and the further the cup and its pointer move round the scale. So the needle movement is proportional to engine r p m. Because the system measures frequency rather than voltage, changes in wiring resistance or generator voltage do not upset the reading.
Part 4 · Induction motor
The induction motor Named because AC is induced in the rotor by the rotating field The most common AC motor: simple, robust, cheap Cheap because the rotor is self-contained : not connected to the supply No commutator, no slip rings, no brushes Rotor speed is always slightly below synchronous speed stator windings (AC) air gap cage bars (no supply) laminated rotor
Chapter 15 · AC Motors
11
e-books by eatpl.in · © 2026 · Do not copy or distribute
The induction motor gets its name from the fact that an alternating current is induced in its rotor by the rotating magnetic field of the stator. It is the most commonly used AC motor because it is simple, robust and relatively cheap to make. The low cost comes mainly from the rotor, which is a self-contained unit, not connected to the supply in any way. There is no commutator, there are no slip rings and there are no brushes, so there is almost nothing to wear out except the bearings. In the 3D view, the stator field, the blue arrow, turns at synchronous speed, set by the supply frequency. The rotor follows, but notice that it turns slightly slower than the field, so the field keeps slipping past it. That small difference in speed is not a defect. It is exactly what makes the induction motor work, as we will see in a moment.
Construction
The squirrel-cage rotor A cylindrical laminated iron core Copper (or aluminium) bars evenly spaced round it, lengthways Bars joined at each end by end rings : a squirrel cage Bars have very low resistance , so a large current can flow Stator windings set by the number of poles and phases complete rotor bars and end rings alone a closed circuit of very low resistance
Chapter 15 · AC Motors
12
e-books by eatpl.in · © 2026 · Do not copy or distribute
Here is the induction motor’s rotor, the squirrel cage. It starts with a cylindrical core of iron laminations, which carries the magnetic flux and keeps eddy currents low. Set into the core, running lengthways, are a number of copper bars, evenly spaced round the circumference. At each end, all the bars are joined together by end rings of the same material. Take away the iron and the bars and end rings look just like the exercise wheel of a pet squirrel, which is where the name comes from. The bars are made of very low resistance material, so the whole cage is a closed circuit of very low resistance, and a large current can flow round it. And notice there is no connection to the supply: no brushes, no slip rings. The stator around it carries windings whose number depends on the number of poles and on the number of phases of the supply.
How it works
How the cage is dragged round The rotating field cuts the rotor bars An e.m.f. is induced in each bar Low resistance: a relatively large current flows round bars and end rings That current makes its own field , which reacts with the stator field: torque By Lenz’s law the rotor turns to reduce the cutting : it chases the field stator field sweeping round rotor bar (end view) force: bar follows 1. Field cuts the bar: e.m.f. induced 2. Low resistance: large current flows 3. Current in a field: force on the bar 4. Rotor turns the same way as the field
Chapter 15 · AC Motors
13
e-books by eatpl.in · © 2026 · Do not copy or distribute
How does a rotor with no supply produce torque? The rotating field sweeps past the bars of the cage, and as its lines of flux cut each bar, an e m f is induced in it. The cage is a closed circuit of very low resistance, so even a modest e m f drives a relatively large current along the bars and round the end rings. Now we have current-carrying conductors sitting in a magnetic field, so there is a force on each bar. Put another way, the rotor current sets up its own magnetic field, and this interacts with the rotating stator field to produce torque. Which way does the rotor turn? Lenz’s law says the induced current acts to oppose its cause, and its cause is the field moving past the bars. The rotor reduces that relative motion by turning the same way as the field, chasing it round, but never quite catching it.
Slip
Slip: the rotor always lags the field 0 2000 4000 6000 8000 10000 12000 rotor 11 400 rpm slip 600 rpm Ns 12 000 rpm rpm Slip = (Ns − Nr) ÷ Ns Ns = 120 × 400 ÷ 4 = 12 000 rpm Nr = 12 000 × (1 − 0.05) = 11 400 rpm rotor current frequency = 0.05 × 400 = 20 Hz typical slip about 5 % Why it can never reach Ns At Ns the bars move with the field: no flux cutting → no e.m.f. → no current → no torque. So it always runs slower: “asynchronous” motor Slip speed (rotor slip) = synchronous speed − rotor speed. A typical slip is about 5 % . The induction motor is therefore an asynchronous motor.
Chapter 15 · AC Motors
14
e-books by eatpl.in · © 2026 · Do not copy or distribute
Why can the rotor never quite catch the field? If it ever reached synchronous speed, the bars would be moving at exactly the speed of the field, so no flux would cut them, no e m f would be induced, no current would flow, and there would be no torque at all. The rotor would immediately slow down. So it always runs a little slower, and the difference between synchronous speed and rotor speed is called the slip speed, or rotor slip. As a fraction, slip is synchronous speed minus rotor speed, divided by synchronous speed, and a typical value is about five per cent. Take a four-pole motor on four hundred hertz: the field turns at twelve thousand r p m, and with five per cent slip the rotor turns at eleven thousand four hundred, a slip of six hundred r p m. Because rotor and field never turn together, the induction motor is sometimes called an asynchronous motor.
Speed and load
Torque and speed: the motor adjusts its slip to the load normal load: slip 5 % heavier load: slip 9 % maximum (pull-out) torque starting torque 0% 25% 50% 75% 100% Rotor speed, per cent of synchronous speed Torque Reading the curve • no torque at Ns • small slip: torque rises steeply • more load → more slip, a little slower • overload beyond the peak: motor stalls Speed is set by the supply frequency and the load : more load means a little more slip, more rotor current and more torque.
Chapter 15 · AC Motors
15
e-books by eatpl.in · © 2026 · Do not copy or distribute
The speed of an induction motor depends on two things: the supply frequency, which sets the synchronous speed, and the load. This curve, computed from a simple rotor model, shows the torque the motor produces at each speed. At synchronous speed, on the right, the torque is zero, as we just saw. As the rotor slows a little, the slip increases, the bars are cut faster, more current flows, and the torque rises steeply. The motor settles where its torque equals the load: here at about 5 per cent slip for a normal load. Add load and the motor slows just a little, to more slip, until the torque again matches. If you load it beyond the peak, called the pull-out torque, the torque can no longer keep up and the motor stalls. Notice the starting torque on the left: an induction motor produces real torque from standstill, so a three-phase induction motor starts by itself.
Reversing
Reversing a three-phase motor The field turns in the order of the phase sequence : A-B-C Swap any two of the three supply leads: the sequence becomes A-C-B The field reverses , so the motor runs in reverse Used by actuators that must drive both ways No harm done: nothing blows, nothing overheats A-B-C normal A-C-B two leads swapped Swap any two phases: field and rotor reverse
Chapter 15 · AC Motors
16
e-books by eatpl.in · © 2026 · Do not copy or distribute
How do you make a three-phase motor run backwards? The rotating field turns in the direction of the phase sequence, from coil A to coil B to coil C. The rotor simply follows the field. Now swap any two of the three supply leads, say B and C. The coils are now energised in the order A, C, B, so the field turns the other way, and the rotor slows, stops, and follows it in reverse. That is all there is to it: if a three-phase motor has two phases of its supply reversed, its direction of rotation is reversed too. Actuators that must drive both ways, such as some trim and valve actuators, do exactly this, with relay contacts or switches selecting the sequence. Watch out for the exam distractors: reversing two phases does not blow the fuses, does not overheat the stator and does not stall the motor. It simply runs in reverse.
Single-phase motors
Why a single-phase motor will not start One winding on single-phase AC gives a field that only pulses , it does not rotate It equals two half-strength fields rotating in opposite directions At rest their torques cancel : not self-starting Spin it either way and it keeps running that way Fix: a second, split-phase winding to make a rotating field 0° 45° 90° 135° Pulsating field (navy) = two half-fields turning opposite ways clockwise half-field anticlockwise half-field At standstill the two torques cancel no starting torque: not self-starting once spun either way, it keeps running that way so add a second winding to make a rotating field
Chapter 15 · AC Motors
17
e-books by eatpl.in · © 2026 · Do not copy or distribute
Single-phase induction motors have a problem. A single winding fed with single-phase AC produces a field that only grows, collapses and reverses along one axis. It pulses; it does not rotate. A useful way to picture it is as two fields of half the strength, rotating in opposite directions. Add them up and, as the diagrams show, the sideways parts cancel and you are left with the pulsating field. At standstill, each half-field pulls the rotor equally in its own direction, so the torques cancel and the motor will not start. Strangely, if you give the rotor a spin by hand, either way, it will run up to speed in that direction, because the field turning the same way as the rotor then wins. So single-phase induction motors are not self-starting, and they need a way of making a rotating field to get going. The most common method is a split-phase winding.
Starting methods
Split-phase starting A second (start ) winding is placed at 90° to the main winding. If its current can be made to lead or lag the main current by about 90° , a rotating field is produced.
Method How the phase shift is made Notes Resistance start Start winding of high resistance (fine wire) Simple; modest phase shift Inductance start Extra inductance in one winding Current lags further Resistance / inductance start Combination of both Exam rule: suited to more powerful motors Capacitance start Capacitor in series with the start winding Current leads , close to 90°; exam rule: usually under 2 HP
The choice depends on the power output of the motor. Once running, a centrifugal switch often disconnects the start winding.
Chapter 15 · AC Motors
18
e-books by eatpl.in · © 2026 · Do not copy or distribute
The common way to start a single-phase induction motor is a split-phase winding. A second winding, the start winding, is placed at ninety degrees to the main winding. If the current in the start winding can be made to lead or lag the current in the main winding by about ninety degrees, the two windings together behave like a two-phase stator and produce a rotating field. There are four ways to make that phase shift. Resistance starting uses a start winding of high resistance. Inductance starting adds inductance to make one current lag further. Resistance and inductance starting combines the two. And capacitance starting puts a capacitor in series with the start winding, so its current leads, giving a shift close to ninety degrees. Which method is used depends on the power output of the motor. For the exam, remember: capacitance-started motors are usually below two horsepower, so for a powerful single-phase motor, choose the resistance and inductance starter.
Example circuit
A capacitor-start motor Main winding directly across the supplyStart winding in series with a capacitor The capacitor makes the start current lead by about 90° Two currents 90° apart in windings 90° apart: a rotating field A centrifugal switch can drop out the start winding near full speed main winding capacitor start winding centrifugal switch (opens near speed) I main I start leads ≈ 90°
Chapter 15 · AC Motors
19
e-books by eatpl.in · © 2026 · Do not copy or distribute
Here is the circuit of a capacitor-start motor. The main winding is connected straight across the single-phase supply. In parallel with it is the start winding, placed at ninety degrees to the main winding round the stator, and connected in series with a capacitor. The main winding is mostly inductive, so its current lags the supply voltage. The capacitor makes the start-winding current lead instead, and the two currents end up about ninety degrees apart, as the little phasor diagram shows. Two windings ninety degrees apart in space, carrying currents ninety degrees apart in time, produce a rotating field, just as three phases do, so the motor starts. Once it is up to speed, the single-phase field alone can keep it running, so on many motors a centrifugal switch opens and disconnects the start winding and capacitor, leaving the main winding to do the work.
Fault operation
Losing one phase of a three-phase motor Occasionally one phase of the supply fails (fuse, wire, contact) A lightly loaded motor already running keeps running , at reduced speed: exam figure about half It hums , draws more current and runs hot Motors are often in remote places, so the fault goes unnoticed Next time it is selected it will not start : the field only pulses A B C phase lost hum Running, light load runs on, slower (exam: ~half speed) Noise and heat humming, rising current, overheating Remote location fault often goes unnoticed Next selection will not start: only a pulsating field
Chapter 15 · AC Motors
20
e-books by eatpl.in · © 2026 · Do not copy or distribute
What happens if one phase of the supply to a three-phase induction motor fails, perhaps through a blown fuse or a broken wire? The motor is now effectively a single-phase motor. If it was already running and only lightly loaded, it will probably keep turning, just as a single-phase motor keeps running once it is spinning. It runs slower, and the figure the exam expects is about half its normal speed. It also hums, draws more current in the remaining phases and runs hot. Because aircraft motors are often mounted in remote places, such as inside fuel tanks or equipment bays, nobody may notice the hum. The fault usually becomes apparent the next time someone tries to run the motor: with only two lines connected, the field merely pulses, there is no starting torque, and it will not start. So the classic exam answer is: runs at about half speed, but will not start on its next selection.
On the aircraft
Where AC motors work on an airliner Fuel pumps Three-phase induction motors drive the tank booster pumps, immersed in fuel.
Hydraulic pumps AC motor-driven pumps back up the engine-driven pumps.
Fans Avionics cooling, recirculation and equipment fans: induction motors.
Gyroscopes Gyro rotors in instruments are small, fast induction motors on 115 V 400 Hz.
Rpm indicator Synchronous motor in the indicator, fed by an engine-driven tacho-generator.
Actuators Reversible three-phase motors, with brakes and clutches, drive valves and trims.
Chapter 15 · AC Motors
21
e-books by eatpl.in · © 2026 · Do not copy or distribute
Where will you find AC motors on an aircraft? Most of the big loads are three-phase induction motors running on one hundred and fifteen volts, four hundred hertz. The fuel booster pumps sit in the tanks, immersed in fuel, which is one reason a motor with no brushes and no sparks is so welcome there. AC motor-driven hydraulic pumps back up the engine-driven pumps. Avionics cooling fans, recirculation fans and many other fans are induction motors. The spinning rotors of electrically driven gyroscopic instruments are small, very fast induction motors. Synchronous motors appear where an exact speed matters, such as in the engine rpm indicator we looked at. And reversible three-phase motors, fitted with brakes and clutches, drive valves and actuators, reversed simply by swapping two phases. Each of these is protected by circuit breakers, and a phase failure can leave one quietly humming in a remote bay.
Side by side
Synchronous and induction motors compared Feature Synchronous motor Induction motor Stator AC (usually three-phase): rotating field AC (single or three-phase): rotating field Rotor Electromagnet fed with DC via slip rings Squirrel cage : no supply, AC induced Brushes Yes, on slip rings (low current) None : no slip rings, no commutatorSpeed Exactly synchronous, independent of loadSlightly below synchronous (slip ~5 %), falls a little with load Self-starting? No : needs induction windings to startThree-phase: yes . Single-phase: no (split phase) Typical use Exact speed: rpm indicators, timers Pumps, fans, gyros, actuators
Chapter 15 · AC Motors
22
e-books by eatpl.in · © 2026 · Do not copy or distribute
Let us put the two motors side by side. Both have AC on the stator to make a rotating field. The synchronous motor’s rotor is an electromagnet fed with DC through slip rings and brushes, which carry only a small current. The induction motor’s rotor is a squirrel cage with no supply: the current in it is induced, so it needs no slip rings, no brushes and no commutator. The synchronous motor runs at exactly synchronous speed, whatever the load, until it falls out of step. The induction motor runs slightly below synchronous speed, typically five per cent slip, and slows a little more as load increases. The synchronous motor is not self-starting and needs induction windings to get going. A three-phase induction motor starts by itself, but a single-phase one needs a split-phase winding. Use the synchronous motor where exact speed matters, and the induction motor for nearly everything else.
Exam traps
Where marks are lost Which part gets DC? Synchronous: AC to the stator , DC to the rotor . Not the other way round.
Speed depends on… Synchronous speed depends on frequency (and poles), not voltage, current or reactance.
Brushes An induction motor has no slip rings and no brushes . “Slip rings but no brushes” is a trap.
Rotating field where? The rotating field is created in the stator , and the rotor follows it.
Cage rotor Not connected to the supply; low resistance; runs below synchronous speed.
Faults Two phases swapped: reverses . One phase lost: runs at about half speed, won’t restart .
Chapter 15 · AC Motors
23
e-books by eatpl.in · © 2026 · Do not copy or distribute
Here are the classic traps. First, in a synchronous motor, the AC goes to the stator and the DC goes to the rotor; options that put DC on the stator are wrong. Second, synchronous speed depends on the supply frequency and the number of poles, not on voltage, current or reactance. Third, an induction motor has no slip rings and no brushes at all; an option offering slip rings without brushes is a trap, because the cage rotor needs no connection of any kind. Fourth, the rotating field of an induction motor is created in the stator, not in the rotor, and it is a rotating field, not a stationary one. Fifth, the squirrel cage is not connected to the supply, has very low resistance and never reaches synchronous speed. And sixth: swap two phases and the motor reverses; lose one phase and a running motor carries on at about half speed but will not start next time.
Summary
What to take into the exam Why AC No commutator arcing at altitude; speed set by frequency.
Rotating field Three-phase stator: constant-strength field turning at Ns.
Synchronous DC rotor via slip rings, locks on at exactly Ns. Not self-starting.
Ns Ns = 120 f / p. 4 poles at 400 Hz = 12 000 rpm.
Rpm indicator Tacho-generator → synchronous motor → magnet and drag cup.
Induction Cage rotor, AC induced, no brushes. Simple, robust, cheap.
Slip (Ns − Nr)/Ns ≈ 5 %. Asynchronous. Speed set by frequency and load.
Faults and starting Swap 2 phases: reverses. Lose 1: half speed, won’t restart. Single-phase: split phase.
Chapter 15 · AC Motors
24
e-books by eatpl.in · © 2026 · Do not copy or distribute
Let us sum up. AC motors avoid the commutation and brush problems of DC motors, which get worse at altitude, and their speed is set by the supply frequency. A three-phase stator makes a magnetic field of constant strength that rotates at synchronous speed, which is one hundred and twenty times the frequency divided by the number of poles: twelve thousand r p m for four poles at four hundred hertz. The synchronous motor has a DC-fed rotor that locks onto the field and runs at exactly that speed, but it is not self-starting; it is used in the engine rpm indicator with a tacho-generator and drag cup. The induction motor has a squirrel-cage rotor with no supply and no brushes; the field induces currents in it and drags it round with a slip of about five per cent. Swap two phases to reverse it, start single-phase motors with a split-phase winding, and remember that a lost phase leaves a motor humming at about half speed, unable to restart.