Electrics · Chapter 11
AC Alternators and Constant-speed Drives How aircraft alternators are built and excited, how star and delta windings give 115 and 200 volts, how voltage is regulated, and how a constant speed drive or VSCF holds 400 hertz.
constant speed · constant frequency 115/200 V · 400 Hz · three-phase
© 2026 eatpl.in. For the personal study of eatpl.in students only. Do not copy or distribute.
e-books by eatpl.in · © 2026 · Do not copy or distribute
Chapter eleven is about the machines that make the AC: aircraft alternators and the drives that turn them. We will see why almost every alternator has its field on the rotor and its output on the stator, how brushless machines with a permanent-magnet generator excite themselves with no brushes at all, and how three windings in a star give one hundred and fifteen and two hundred volts. Then we tackle the big problem: the engine speed changes all the time, but the frequency must stay at four hundred hertz. The constant speed drive, the integrated drive generator and the variable-speed constant-frequency system are three answers to that problem.
Chapter 11 roadmap
From the spinning field to a steady 400 Hz 1 · The machine Rotating armature or rotating field ? Why the field turns and the output is taken from the stator , and why ratings are in kVA .
2 · The windings Single phase and three phase ; star (115/200 V, earthed neutral) and delta .
3 · Excitation Brushed and brushless machines, the PMG , exciter and rotating rectifier , and voltage regulation.
4 · Constant frequency Why speed must be held, and the constant speed drive : swash plate, governor, overdrive and underdrive.
5 · IDG and protection The integrated drive generator , its oil, warnings, quill drive and the drive disconnect .
6 · VSCF and the aircraft Constant frequency electronically , and where the generators sit on an A320.
Chapter 11 · AC Alternators and Constant-speed Drives
2
e-books by eatpl.in · © 2026 · Do not copy or distribute
Here is the plan. First, the machine itself: we compare rotating-armature and rotating-field alternators and see why aircraft use the second kind, and why alternators are rated in kVA. Second, the windings: single phase and three phase, and the star and delta connections, with the line and phase values you must know. Third, excitation: how the rotating field gets its DC, in brushed and especially in brushless machines with a permanent-magnet generator and a rotating rectifier, and how the voltage regulator holds one hundred and fifteen volts. Fourth, the frequency problem, and the constant speed drive that solves it. Fifth, the integrated drive generator, its oil, its warnings and how to disconnect it. And finally, the electronic answer, variable-speed constant-frequency, and a look at where the generators sit on an A320.
Part 1 · The job
What an aircraft alternator must deliver Large aircraft distribute AC ; the standard is 115/200 V, 400 Hz, three-phase 28 V DC comes from TRUs ; the battery is kept for emergenciesOne generator per engine, plus an APU generator , feeding a hierarchy of bus bars Another name for an AC generator: alternator In a DC generator the armature always rotates; in an alternator usually it does not GEN 1 IDG, 115/200 V APU GEN constant speed GEN 2 IDG, 115/200 V AC BUS 1 · 3-phase 400 Hz AC BUS 2 · 3-phase 400 Hz TRU AC → 28 V DC TRU AC → 28 V DC DC BUS 1 · 28 V DC BUS 2 · 28 V Battery emergency DC
Chapter 11 · AC Alternators and Constant-speed Drives
3
e-books by eatpl.in · © 2026 · Do not copy or distribute
Let us start with the job. Large transport aircraft distribute alternating current, and the industry standard for constant-frequency systems is one hundred and fifteen volts phase, two hundred volts line, four hundred hertz, three-phase. The DC that the aircraft still needs, twenty-eight volts, comes from transformer rectifier units fed by the AC buses, while the battery is kept for emergencies. Each engine drives its own generator and the APU drives another, and they feed a system of bus bars arranged so that a failure loses as little as possible. An AC generator is usually called an alternator. There is one important difference from the DC generators you studied earlier. In a DC generator the armature, where the output is induced, always rotates, because it has to feed the commutator. In an alternator that is generally not true, and the next slide shows why.
Part 1 · The machine
Rotating armature or rotating field? Rotating armature : armature turns in a stationary field, like a DC machine; output via slip rings Used only in very small alternators Rotating field : the rotor carries the field ; the armature is the stator Output is taken from the stationary stator : little brush arcing Only the low field current passes through slip rings (or none, if brushless) Rotating armature small machines only N S armature field: stationary Output (heavy current) via slip rings and brushes Arcing, wear, heavy rotor, hard to insulate and cool rotating: armature Rotating field almost all aircraft alternators N S armature (stator): stationary Output from the stationary stator: no brushes in it Only low DC field current through the slip rings rotating: field (DC)
Chapter 11 · AC Alternators and Constant-speed Drives
4
e-books by eatpl.in · © 2026 · Do not copy or distribute
There are two ways to build an alternator. In the rotating-armature type, the armature turns inside a stationary magnetic field, just as in a DC generator, but instead of a commutator it has slip rings, so the output stays AC. The trouble is that the full output current, which may be hundreds of amps, must pass through the brushes and slip rings. That type is only used for very small alternators. Nearly every practical alternator is the rotating-field type. The rotor carries the field windings, and the armature windings sit in the stator, which does not move. The output is taken straight from those stationary windings, so the heavy current never passes through a sliding contact and arcing at the brush gear is greatly reduced. Only the small field current has to reach the rotor through slip rings, and in a brushless machine, as we will see, not even that.
Part 1 · The machine
The rotating-field alternator Rotor = field , energised by a permanent magnet or by DC from a separate source The field must be DC , to keep the rotor's polarity fixed Field current is small , so slip rings and brushes carry little Output from the stationary three-phase stator: no sliding contacts for heavy current Stator windings are easy to insulate and cool N S stator (armature): 3-phase output A B C out rotor: DC field via slip rings, low current field MUST be DC to keep its polarity on the rotor
Chapter 11 · AC Alternators and Constant-speed Drives
5
e-books by eatpl.in · © 2026 · Do not copy or distribute
Here is a rotating-field alternator with half the stator cut away so you can see inside. The rotor is the field: an electromagnet, or in small machines a permanent magnet. If it is an electromagnet, its winding must be fed with DC, because the rotor's north and south poles have to stay the same. Feed it with AC and the poles would reverse all the time. Watch the red arrow, the rotor's north pole, sweeping round inside the stator. As it passes each set of windings it induces a voltage in them, so the three-phase output comes from the stationary stator and goes out through solid connections, carrying the heavy current with no brushes at all. The DC excitation reaches the turning rotor through two slip rings, but it is only a small current, so wear and arcing are slight. And because the stator windings do not move, they are easy to insulate and to cool.
Part 1 · The machine
Why the rotating armature lost All four problems come from spinning the heavy output winding . Put the light field winding on the rotor instead and they shrink.
Heavy rotor The rotating armature coils are heavy , and centrifugal forces on them are high.
Insulation Insulating windings that spin at high speed is difficult .
Brush resistance The resistance across the brushes to the slip rings is high, and it carries the full output.
Cooling and weight Rotating coils are hard to cool , giving a poor power-to-weight ratio .
Chapter 11 · AC Alternators and Constant-speed Drives
6
e-books by eatpl.in · © 2026 · Do not copy or distribute
Why did the rotating armature lose out? There are four reasons, and they are a favourite source of exam options. First, the armature coils are heavy, and spinning them at aircraft generator speeds puts very high centrifugal forces on them. Second, insulating windings that are whirling round is difficult; the insulation is stressed mechanically as well as electrically. Third, every amp of output has to cross the brushes and slip rings, and the resistance there is high, so there is heat, wear and arcing, which gets worse at altitude. Fourth, rotating coils are hard to cool, so the machine has to be bigger for the same output, giving a poor power-to-weight ratio. Put the field on the rotor instead, and all four problems shrink, because the field winding carries only a small current and the heavy output windings stay still in the stator, where they can be insulated and cooled properly.
Part 1 · The machine
Why alternators are rated in kVA Maximum output is set by the heating the armature windings can stand Heating depends on current (I²R), whatever the power factor So alternators are rated by volts × amps : VA or kVA , the apparent power Worked: 90 kVA at 115 V per phase: 90 000 ÷ (3 × 115) = 261 A per phase At p.f. 0.8 it delivers only 72 kW , but the windings are just as hot Same 90 kVA alternator, same current, same heating p.f. 1.0 90 kW 90 kVA 0 kVAR phase current 261 A: same I²R heating in the windings p.f. 0.8 72 kW 90 kVA 54 kVAR phase current 261 A: same I²R heating in the windings p.f. 0.5 45 kW 90 kVA 78 kVAR phase current 261 A: same I²R heating in the windings I = 90 000 VA ÷ (3 × 115 V) = 261 A per phase so the limit is kVA (current), not kW
Chapter 11 · AC Alternators and Constant-speed Drives
7
e-books by eatpl.in · © 2026 · Do not copy or distribute
How much can an alternator deliver? The limit is heat. Current flowing in the armature windings heats them, and too much heat will, in the extreme, destroy the insulation. That heating depends on the current, the I squared R loss, and it does not care what the power factor is. A load at a poor power factor draws the same current, and so makes the same heat, as a resistive load of the same volt-amps, even though it does less useful work. So alternators are rated by volts times amps, in volt-amperes or kVA, the apparent power, and not in kilowatts. Let us put numbers on it. A ninety kVA alternator at one hundred and fifteen volts per phase can supply ninety thousand divided by three times one hundred and fifteen, about two hundred and sixty-one amps per phase. At a power factor of zero point eight that is only seventy-two kilowatts of true power, but the windings run just as hot.
Part 2 · The windings
The single-phase alternator Stator coils connected in series , series-aiding : their voltages are in phase and add Rotor: two poles of opposite polarity Output rises to a maximum one way, falls to zero, rises to a maximum the other way , back to zero One cycle per revolution for two poles Simple, but aircraft main generators are three-phase coil 1 coil 2 N S series-aiding output one cycle per turn Two coils opposite each other, connected so their voltages add
Chapter 11 · AC Alternators and Constant-speed Drives
8
e-books by eatpl.in · © 2026 · Do not copy or distribute
Before three phases, one. In a single-phase alternator the stator has coils on opposite sides, and they are connected in series so that their voltages help each other. We call that series-aiding: the voltages induced in the two coils are in phase and simply add up to give the output. The rotor has two poles of opposite polarity. As the north pole sweeps past coil one, the south pole is sweeping past coil two, so both coils see their maximum at the same instant. The output rises to a maximum in one direction, falls to zero, rises to a maximum in the other direction and falls to zero again: one complete cycle for each turn of a two-pole rotor. Single-phase machines are simple, but they are not used for aircraft main power. For that we need three phases.
Part 2 · The windings
The three-phase alternator A B C 120° 120° 0° 120° 240° 360° 480° 600° 720° Three-phase alternator 3 windings, 120° apart same frequency and size phase sequence A → B → C Advantages: better power-to-weight easier to parallel feeds 1-phase and 3-phase loads lighter cables Polyphase: two or more single-phase windings spaced evenly round the stator. The number of separate stator windings gives the number of phases .
Chapter 11 · AC Alternators and Constant-speed Drives
9
e-books by eatpl.in · © 2026 · Do not copy or distribute
A polyphase, or multi-phase, alternator has two or more single-phase windings spaced evenly round the stator. Each winding produces its own voltage, all at the same frequency, but out of phase with each other by an equal number of degrees. The number of separate stator windings decides the number of phases. The three-phase alternator is the standard for aircraft. Its three windings are set one hundred and twenty degrees apart in the order A, B, C, so the three outputs are one hundred and twenty degrees apart electrically. In the graph, phase A reaches its positive peak first, then B, then C: the phase sequence A B C. The three phases are independent of each other. Three-phase machines give a better power-to-weight ratio and are easier to connect in parallel. And a three-phase system can feed both three-phase loads, like motors, and single-phase loads, connected across one phase.
Part 2 · The windings
The four-wire star connection One end of each phase joined at the neutral point , earthed to the airframe as the return Phase voltage : line to neutral, 115 V . Line voltage : between two lines, 200 V Line voltage = 1.73 × phase voltage (the vector sum of two phases) Line current = phase current The neutral carries any out-of-balance current, so star copes with unequal loads An earth fault on one phase: a very large neutral current , and all three phases are affected A C B neutral → airframe (earth return) V line to line: 200 V Phase voltage: line to neutral = 115 V Line voltage: line to line = 1.73 × 115 ≈ 200 V Line current = phase current Neutral carries any out-of-balance current
Chapter 11 · AC Alternators and Constant-speed Drives
10
e-books by eatpl.in · © 2026 · Do not copy or distribute
The three phases can be connected in two ways. In the star connection, one end of each phase winding is joined to a common point, the neutral, and in aircraft the neutral is earthed to the airframe and used as the return. A voltmeter between a line and the neutral reads across one winding: the phase voltage, one hundred and fifteen volts. Between two lines it reads across two windings whose voltages are one hundred and twenty degrees apart, and the vector sum is one point seven three times as much, two hundred volts, the line voltage. Line current equals phase current. The neutral carries any out-of-balance current, which lets star cope with different loads on each phase. That is why it is the aircraft standard. But if one phase faults to earth, the neutral carries a very heavy current, and because all three phases share one rotor field and one regulator, the whole machine is affected.
Part 2 · The windings
Star and delta: the numbers to know √3 = 1.73 . In a star system the line voltage is the vector sum of two phase voltages 120° apart, not their simple sum.
Quantity Star (aircraft standard) Delta Measured between Phase: line and neutral. Line: two lines Line and phase: the same two terminals Voltage VL = 1.73 × VP : 115 V → 200 V VL = VP Current IL = IP IL = 1.73 × IP : 10 A → 17.3 ANeutral Yes: 4 wires, earthed to the airframe No: 3 wires Unbalanced loads Coped with: the neutral carries the difference Cannot cope Bridging two phases 115 V phases: 115 × 1.73 ≈ 200 V AC n/a Typical use Main aircraft generators Tacho generators, speed sensors
Chapter 11 · AC Alternators and Constant-speed Drives
11
e-books by eatpl.in · © 2026 · Do not copy or distribute
Root three is one point seven three. In star, the phase voltage is measured between a line and the neutral, and the line voltage between two lines. The line voltage is one point seven three times the phase voltage, so one hundred and fifteen volt phases give two hundred volts between lines. It is a vector sum, not two hundred and thirty. Line current equals phase current. In delta, line and phase voltages are measured across the same two terminals, so they are equal, but each line carries the vector sum of two phase currents, one point seven three times the phase current; ten amps per phase gives seventeen point three amps per line. Star has a neutral and four wires and copes with unbalanced loads; delta has three wires and cannot. A classic exam question: bridge two phases of a one hundred and fifteen volt star system and you get about two hundred volts AC.
Part 2 · The windings
The delta connection Ends of the phases joined into a closed mesh ; lines taken from the corners Line voltage = phase voltage Line current = 1.73 × phase current No neutral : cannot cope with unbalanced loads Not used for distribution; used for special jobs such as tacho generators and speed sensors line 1 line 2 line 3 no neutral Line voltage = phase voltage Line current = 1.73 × phase current No neutral: cannot cope with unbalanced loads Used for special jobs, e.g. tacho generators, speed sensors
Chapter 11 · AC Alternators and Constant-speed Drives
12
e-books by eatpl.in · © 2026 · Do not copy or distribute
In the delta connection the end of each phase winding is joined to the start of the next, forming a closed triangle, or mesh, and the three lines are taken from the corners. The loads are connected in the same triangular way. Because each pair of lines is connected straight across one winding, the line voltage is the same as the phase voltage. The current, though, is different: each line is fed by two windings, whose currents are one hundred and twenty degrees apart, so the line current is one point seven three times the phase current. The big drawback is that there is no neutral point. With no neutral to carry the out-of-balance current, a delta system cannot cope with unequal loads on its phases, and aircraft loads are never perfectly balanced. So delta is not used for the main distribution system. You will meet it in small, special machines, such as tacho generators and speed sensors.
Part 3 · Excitation
The brushed alternator Field current at first from the DC bus (battery), then from rectified AC DC reaches the rotating field through brushes and slip rings The voltage regulator samples the 115 V output and adjusts the excitation current Holds the voltage whatever the speed and load Simplest regulator: a variable resistance in series with the field (the carbon pile idea) DC bus start: battery Rectified AC once running Regulator variable resistance brushes + slip rings N S DC field current 115 V AC out senses output
Chapter 11 · AC Alternators and Constant-speed Drives
13
e-books by eatpl.in · © 2026 · Do not copy or distribute
Both kinds of rotating-field alternator need DC for the rotor. In the brushed alternator, that DC is fed through brushes and slip rings. At start-up it comes from the aircraft DC bus bar, in other words the battery, and once the machine is running it comes from rectified AC. Between the supply and the field sits the voltage regulator. It samples the alternator output, one hundred and fifteen volts AC, and adjusts the excitation current to keep that voltage correct whatever the alternator speed and load. In its simplest form the regulator is just a variable resistance in series with the field coil, the same principle as the carbon pile regulator you met with DC generators: if the voltage is high, the resistance increases and the field current falls; if it is low, the resistance decreases and the field strengthens. Modern regulators do the same job electronically.
Part 3 · Excitation
The brushless alternator PMG permanent-magnet generator Exciter field: stator armature: rotor Rotating rectifier diodes: AC → DC on the shaft Main generator field: rotor output: stator one shaft · no brushes, no slip rings anywhere No brushes or slip rings: very reliable , no brush wear , high power-to-weight . Typical output 115/200 V, 400 Hz, three-phase.
Chapter 11 · AC Alternators and Constant-speed Drives
14
e-books by eatpl.in · © 2026 · Do not copy or distribute
The brushless alternator gets rid of brushes completely by putting three machines on one shaft. On the left is the permanent-magnet generator, the P M G: a magnet on the shaft spins inside its own small stator and produces AC as soon as the shaft turns. Next is the exciter, a small generator built the other way round: its field is on the stator, and its armature turns with the shaft. Then comes the rotating rectifier, a set of diodes on the shaft, which turns the exciter's AC into DC. That DC feeds the main rotating field, on the right, which induces the output in the main stator. Because the exciter armature, the diodes and the main field all turn together, the current passes from one to the next through fixed wires, with no sliding contact anywhere. The result is a very reliable machine, with no brush wear and a high power-to-weight ratio.
Part 3 · Excitation
The excitation chain: small current controls big ROTATING (on the shaft) STATIONARY PMG stator AC from permanent magnets GCU rectifies and regulates Exciter field stator, DC Main stator 115/200 V 400 Hz out PMG rotor permanent magnets Exciter armature rotor, AC Rotating rectifier AC → DC Main field rotor, DC output voltage sensed regulate the small exciter field current → control the large main field current → control the output voltage Self-excited : some permanent magnetism in the exciter starts it, and the main output, regulated, then feeds the exciter field. Externally excited : no residual magnetism in the exciter.
Chapter 11 · AC Alternators and Constant-speed Drives
15
e-books by eatpl.in · © 2026 · Do not copy or distribute
Let us trace the excitation step by step. The top row is stationary, the bottom row turns with the shaft. The P M G rotor's magnets induce AC in the P M G stator the moment the shaft turns. The generator control unit, the G C U, rectifies and regulates that into a DC current for the exciter field, which is on the stator. The exciter armature, turning in that field, produces AC; the rotating rectifier turns it into DC; and that DC is the main field current. The main field induces the output in the main stator, and the G C U senses the output voltage. So the regulator only has to control the small exciter field current to control the much larger main field current, and so the output. Brushless machines are described as externally excited, with no residual magnetism in the exciter, or self-excited, where permanent magnetism in the exciter starts the machine and the regulated main output then feeds the exciter field.
Part 3 · Excitation
Voltage regulation: control the field Output voltage rises with field (excitation) current To increase output voltage, increase the field current Regulator senses the output and varies the rotating field strength In a brushless machine it does this through the exciter field current Frequency is set by speed; voltage by excitation Even with a CSD, the alternator still needs a voltage regulator 115 V field (excitation) current → output V more field current, more volts load increases output volts start to fall regulator raises field current voltage back to 115 V
Chapter 11 · AC Alternators and Constant-speed Drives
16
e-books by eatpl.in · © 2026 · Do not copy or distribute
The alternator's output voltage depends on the strength of its rotating field, and so on the field current. The curve shows it: more field current, more volts, until the iron begins to saturate and the curve levels off. To increase the output voltage you increase the field current, and that is all a voltage regulator does. It senses the output voltage and varies the strength of the rotating field. In a brushless machine it does that indirectly, by varying the small exciter field current. Look at the loop below. A big load comes on; the internal voltage drop rises and the output voltage starts to fall; the regulator raises the field current; the voltage comes back to one hundred and fifteen. Keep two ideas separate: the frequency depends on speed, and the voltage on excitation. So even an alternator driven at constant speed by a constant speed drive still needs a voltage regulator, because its voltage would otherwise change with the load.
Part 4 · Constant frequency
Constant frequency needs constant speed f = (poles ÷ 2) × (rpm ÷ 60). For 400 Hz each machine needs one exact speed. Engine speed varies widely, so a constant speed device must sit between engine and generator.
Poles Pole pairs Speed for 400 Hz If driven 25% too slow 2 1 24 000 rpm 300 Hz 4 2 12 000 rpm 300 Hz 6 3 8 000 rpm 300 Hz 8 4 6 000 rpm 300 Hz 12 6 4 000 rpm 300 Hz
Driven straight from the gearbox, the output is frequency wild (next chapter). Holding the alternator speed constant gives a constant-frequency supply that can run motors at a fixed speed and be paralleled.
Chapter 11 · AC Alternators and Constant-speed Drives
17
e-books by eatpl.in · © 2026 · Do not copy or distribute
Why go to so much trouble over speed? Because frequency is fixed by poles and speed. For four hundred hertz, a two-pole machine must turn at twenty-four thousand r p m, a four-pole at twelve thousand, a six-pole at eight thousand, an eight-pole at six thousand, and a twelve-pole at four thousand. Each design has exactly one correct speed. Drive any of them a quarter too slowly and you get three hundred hertz. Now think of the engine: from idle to take-off power its gearbox speed changes a great deal. Driving the alternator straight from the gearbox gives a frequency that wanders with engine speed, called frequency wild, which you will meet in the next chapter. Driving the engine itself at a constant speed is not practical. So if we want a constant-frequency supply, which we need for motors, for many instruments, and for paralleling generators, we must put a device between the engine and the generator that turns a varying input speed into a constant output speed.
Part 4 · Constant frequency
The constant speed drive unit (CSD) Engine gearbox speed varies Hydraulic pump swash plate sets output oil Hydraulic motor drives the generator Generator constant speed Governor positions the swash plate frequency sensed Oil reservoir separate from engine oil 400 Hz held within 5%: 380–420 Hz input speed varies · output speed constant Engine-driven hydraulic pump → hydraulic motor → alternator. Swash plate angle set by the governor ; the load controller senses frequency. Oil: own reservoir, separate from engine oil . Typical limits 380–420 Hz .
Chapter 11 · AC Alternators and Constant-speed Drives
18
e-books by eatpl.in · © 2026 · Do not copy or distribute
The constant speed drive unit, the C S D, sits between the engine gearbox and the alternator. Inside, the engine drives a hydraulic pump, and the pump's oil drives a hydraulic motor, which turns the generator. The pump is a variable-displacement type: the angle of its swash plate decides how much oil it delivers, and so how fast the motor turns. The swash plate is positioned by a speed governor, and the governor is trimmed by a load controller that senses the alternator's output frequency. Watch the scene. The input speed starts low. Then the engine speeds up through straight through to underdrive, and the swash plate moves to compensate, while the generator keeps turning at the same speed and the frequency stays steady at four hundred hertz. The oil drives, lubricates and cools the unit, and it has its own reservoir, entirely separate from the engine oil. Most C S Ds hold the frequency within five per cent: three hundred and eighty to four hundred and twenty hertz.
Part 4 · Constant frequency
Overdrive, straight through and underdrive 3000 3000 4000 4000 5000 5000 6000 6000 7000 7000 8000 8000 9000 9000 10000 10000 direct drive (frequency wild) OVERDRIVE engine slower than generator UNDERDRIVE engine faster than generator straight through CSD input speed (engine gearbox), rpm generator rpm Example: 8-pole generator needs 6000 rpm for 400 Hz input 4500 rpm: CSD adds speed input 6000 rpm: straight through input 9000 rpm: CSD takes speed off output stays at 6000 rpm so f = 4 × 100 = 400 Hz Overdrive : engine (input) slower than generator. Straight through : same speed. Underdrive : engine faster than generator.
Chapter 11 · AC Alternators and Constant-speed Drives
19
e-books by eatpl.in · © 2026 · Do not copy or distribute
The constant speed drive works in one of three modes, and the names are easy to get the wrong way round. The graph plots generator speed against the C S D input speed from the engine. Our example generator has eight poles, so it needs six thousand r p m for four hundred hertz. When the input is slower than six thousand, at low engine power, the drive must speed things up: that is overdrive, the engine slower than the generator. When the input happens to be exactly six thousand, the drive passes it straight through: straight-through drive. When the engine is turning faster than the generator needs, at high power, the drive takes speed off: underdrive, engine faster than generator. Whatever the input, from four thousand five hundred to nine thousand in this example, the output stays on the flat blue line. Compare the dashed diagonal: that is what a direct drive would do, with frequency following engine speed.
Part 5 · IDG
The integrated drive generator (IDG) CSD and generator in one unit : an IDG (or IDU) Generator section: PMG, exciter, rotating rectifier, main generator ; controlled by a GCU One self-contained oil system : drives, lubricates and cools the stator Its oil is cooled in its own oil cooler Separate CSD and generator: generator cooled by ram air in flight (fan on the ground) CSD section pump, motor, governor differential gearing Generator section PMG, exciter, rectifier, main generator input oil cooler one oil system: drives, lubricates and cools (including the generator stator) disconnect Integrated drive generator (IDG) separate CSD + generator: generator cooled by ram air (fan on the ground)
Chapter 11 · AC Alternators and Constant-speed Drives
20
e-books by eatpl.in · © 2026 · Do not copy or distribute
Modern aircraft combine the constant speed drive and the generator in one casing, called an integrated drive generator, I D G, or integrated drive unit. The drive section contains the hydraulic pump and motor, the governor and the gearing; the generator section is a brushless machine with a P M G, exciter, rotating rectifier and main generator, all on one shaft and controlled by a generator control unit. Integration saves weight and space, and it allows one self-contained oil system to do everything: it drives the hydraulic section, lubricates the bearings and gears, and cools the generator stator windings. That oil is in turn cooled in the I D G's own oil cooler. Compare older installations with a separate C S D and generator, or frequency-wild generators: there the generator is usually cooled by ram air in flight, with some means of drawing air through on the ground. Remember: I D G oil is self-contained, never shared with the engine.
Part 5 · IDG
CSD and IDG warnings and protection OIL °C oil temperature gauge LO PR OVHT warning lights IDG DISC guarded switch CSD alternator quill drive: the weak neck shears if the alternator seizes Low oil pressure Light comes on when CSD oil pressure falls below a set minimum . Often in the disconnect switch.
High oil temperature Monitors the CSD oil outlet temperature : a temperature gauge and an overheat warning.
Quill drive A weak link in the drive: if the alternator seizes, it shears before the CSD is badly damaged.
The cure: disconnect Low pressure or high temperature: disconnect the drive before the unit fails.
Chapter 11 · AC Alternators and Constant-speed Drives
21
e-books by eatpl.in · © 2026 · Do not copy or distribute
The constant speed drive is a hard-working piece of machinery, so the crew are given warnings about it. The two main ones concern its oil. A low oil pressure light comes on when the C S D oil pressure falls below a set minimum. A high oil temperature warning monitors the temperature of the oil leaving the unit, and many panels also have a C S D oil temperature gauge, which shows the trend before the warning comes on. On many panels these lights sit inside the guarded disconnect switch itself. There is also built-in mechanical protection. If the alternator suffers a mechanical failure and seizes, a quill drive, a deliberately weak shaft, shears before major damage can spread back into the C S D. And for low oil pressure or high oil temperature, the cure is in the crew's hands: disconnect the drive, before the unit destroys itself.
Part 5 · IDG
The drive disconnect unit (dog clutch) For a malfunction of the CSD or alternator , the input drive can be disconnected A guarded, momentary switch fires a solenoid ; the dog clutch separates CSD and alternator stop; the engine is not affected Can be done any time the engine is running , in flight or on the ground Reconnect only on the ground, engine stopped , by hand Some aircraft: automatic disconnect by the GCU for certain faults input from engine to CSD / IDG dogs pulled apart solenoid IDG DISC guarded, momentary Any time the engine is running Use for low oil pressure or high oil temperature Reconnect only on the ground, engine stopped, by hand
Chapter 11 · AC Alternators and Constant-speed Drives
22
e-books by eatpl.in · © 2026 · Do not copy or distribute
If the C S D or the alternator malfunctions, the engine input drive can be disconnected, so that the faulty unit stops turning and cannot affect the engine. On the flight deck there is a guarded, momentary disconnect switch. Pressing it energises a solenoid, and the solenoid pulls a pawl that makes the two halves of a dog clutch separate. Watch the scene. The engine side keeps turning. The plunger moves, the dog teeth come apart, and the C S D and generator run down and stop. Disconnection can be done at any time the engine is running, in flight or on the ground, and it is the right action for low oil pressure or high oil temperature. But it is a one-way trip in flight. Reconnecting can only be done manually, on the ground, with the engine shut down. A few aircraft also let the generator control unit disconnect the drive automatically for certain faults.
Part 6 · VSCF
Variable speed, constant frequency (VSCF) A frequency-wild generator driven straight from the engine A generator converter control unit (GCCU) rectifies and filters to DC, then an inverter makes 115/200 V 400 Hz No hydro-mechanical CSD : better reliability and flexibilityElectronics need not sit in the hot engine bay ; built-in test aids fault finding Small scale: frequency-wild AC → DC → static inverter → constant-frequency AC VSCF: variable speed, constant frequency Engine speed varies Generator frequency wild GCCU (electronic) Rectifier full wave + filter Inverter DC → AC + built-in test 115/200 V 400 Hz, 3-phase No hydro-mechanical CSD Electronics can sit away from the hot engine bay More reliable, more flexible Same idea, small scale: frequency-wild AC → rectifier → DC → static inverter → constant-frequency AC for instruments and avionics
Chapter 11 · AC Alternators and Constant-speed Drives
23
e-books by eatpl.in · © 2026 · Do not copy or distribute
There is another way to get constant frequency: let the generator run at whatever speed the engine gives, and fix the frequency electronically. That is the variable-speed constant-frequency system, V S C F. The engine drives the generator directly, so its raw output is frequency wild. A generator converter control unit first passes that output through a full-wave rectifier and filter, turning it into DC, and then an inverter builds a fresh three-phase supply at one hundred and fifteen over two hundred volts, four hundred hertz. There is no hydro-mechanical C S D with all its oil and control mechanisms, which improves reliability. The electronics need not be in the engine compartment with the generator, which makes the installation more flexible, and the unit has built-in test to help the engineers find faults. The same principle is used on a smaller scale on aircraft with only frequency-wild generators: rectify the wild AC to DC and feed a static inverter to give constant-frequency AC for instruments.
Part 6 · On the aircraft
Where the A320's AC comes from IDG 1 · 90 kVA IDG 2 · 90 kVA APU generator · 90 kVA emergency generator (via RAT) A320 family: AC sources (plan view, nose left) Each engine drives an IDG (90 kVA, 115/200 V, 400 Hz). The APU generator needs no CSD because the APU runs at constant speed. An emergency generator is driven via the RAT.
Chapter 11 · AC Alternators and Constant-speed Drives
24
e-books by eatpl.in · © 2026 · Do not copy or distribute
Here is how this looks on a typical modern twin, the A320. Each engine has an integrated drive generator mounted on its accessory gearbox. Each I D G is a ninety kVA brushless machine with a P M G and a constant speed section, cooled by its own oil, and controlled by its own generator control unit, giving one hundred and fifteen over two hundred volts at four hundred hertz. In the tail, the auxiliary power unit drives a third generator, also of ninety kVA. It needs no constant speed drive at all, because the A P U itself is governed to run at a constant speed. For emergencies there is a smaller generator powered through the ram air turbine, and a static inverter can supply essential AC from the batteries. How these sources share the buses, and why the A320 never parallels its generators, is the story of the next chapter.
Summary
What to take into the exam Rotating field Field (DC) on the rotor, output from the stationary stator: low current through slip rings, little arcing. Rotating armature only in tiny machines.
kVA rating Heating depends on current, whatever the power factor, so alternators are rated in kVA.
Three phase Windings 120° apart, sequence ABC. Number of windings = number of phases. Feeds 1-phase and 3-phase loads.
Star and delta Star: VL = 1.73 VP (115/200 V), IL = IP , earthed neutral. Delta: VL = VP , IL = 1.73 IP , no neutral.
Brushless PMG → GCU → exciter field → exciter armature → rotating rectifier → main field → stator output. No brushes.
Regulation More field current, more volts. Regulator varies the rotating field (via the exciter field). Speed sets frequency.
CSD / IDG Pump → motor, swash plate, governor; 380–420 Hz. Oil separate from engine oil. Overdrive = engine slower. Quill drive.
Disconnect For low oil pressure or high temperature, any time engine running. Reset on the ground, engine stopped. VSCF: no CSD.
Chapter 11 · AC Alternators and Constant-speed Drives
25
e-books by eatpl.in · © 2026 · Do not copy or distribute
Aircraft alternators have a rotating DC field and a stationary armature, so the heavy output never crosses a sliding contact. They are rated in kVA because the heating depends on current, whatever the power factor. The number of separate windings gives the number of phases. In star, line voltage is one point seven three times phase voltage and line current equals phase current, with an earthed neutral; in delta it is the other way round, and there is no neutral. A brushless alternator excites itself through a P M G, exciter and rotating rectifier, and its voltage is regulated by varying the field current. Frequency depends on speed, so a C S D or I D G holds the generator at constant speed, within three hundred and eighty to four hundred and twenty hertz, using its own oil. If that oil runs hot or loses pressure, disconnect the drive: in flight it stays disconnected until the engine is stopped on the ground.