Electrics · Chapter 4
Batteries How cells store energy, lead-acid and nickel-cadmium batteries, capacity, charging, thermal runaway and the checks that keep a battery fit to fly.
Ni-Cd 24 V 40 Ah
temp sensor
26 V
+ −
chemical energy ⇄ electrical energy
© 2026 eatpl.in. For the personal study of eatpl.in students only. Do not copy or distribute.
e-books by eatpl.in · © 2026 · Do not copy or distribute
Chapter four is about batteries. Every aircraft with an electrical system carries at least one, and it has three big jobs: it starts the engine or the A P U, it steadies the bus while the generators run, and it is the last source of power when every generator has failed. In this chapter we build up from a single cell to a complete battery, compare the lead-acid type you find in light aircraft with the nickel-cadmium type used on larger aircraft, and learn the numbers examiners love: cell voltages, specific gravities, capacity in ampere hours, the eighty per cent rule and thermal runaway.
Roadmap
From one cell to a battery fit to fly 1 · Cells Primary and secondary cells, capacity in ampere hours, series and parallel.
2 · Lead-acid Plates, acid, specific gravity, cell voltages, charging, temperature, safety.
3 · Nickel-cadmium Construction, flat discharge, state of charge and thermal runaway.
4 · Checks and charging Capacity test, the 80% rule, on-load checks and charging in flight.
Chapter 4 · Batteries
2
e-books by eatpl.in · © 2026 · Do not copy or distribute
Here is the plan for this chapter. We start with the cell, the basic building block, and see the difference between a primary cell, which you throw away, and a secondary cell, which you can recharge. We learn what capacity in ampere hours means and what happens when cells are joined in series or in parallel. Part two is the lead-acid battery: its plates and acid, specific gravity, cell voltages, charging, the effect of temperature and the safety rules. Part three is the nickel-cadmium battery, the type used on most larger aircraft, with its flat discharge curve and its one big danger, thermal runaway. Finally we look at how batteries are checked and charged: the three-monthly capacity test, the eighty per cent rule, the pilot’s on-load check and what the ammeter shows after an engine start.
Part 1 · Why a battery
What the aircraft battery is for The generators are the main source of power; the battery is the standby Engine and APU starting : its heaviest job, a very high current for a short timeEmergency power when all generators fail: essential loads for about 30 minutes Sits on the bus in parallel with the loads, so it steadies the voltage and soaks up surges Converts chemical energy to electrical energy , and back again on charge
DC bus bar (28 V)
G
generator
BAT
battery
charge discharge
starter essential other loads
1 Engine or APU start (largest load)
2 Emergency power if the generators fail
3 Steadies the bus and absorbs surges
4 Ground power for checks with engines off
Chapter 4 · Batteries
3
e-books by eatpl.in · © 2026 · Do not copy or distribute
Let us start with why the battery is there at all. In flight the generators are the main source of electrical power, and the battery is the standby. Its heaviest job is starting the engine or the A P U, which takes a very large current for a short time. Its most important job is emergency power: if every generator fails, the battery alone must keep the essential services running, such as attitude information, essential radios, some lighting and pitot heat, for about thirty minutes, long enough to get the aircraft on the ground. In normal flight the battery sits on the bus bar in parallel with the loads. The generator keeps it charged, and because it is connected across the bus it also helps to steady the voltage and absorb surges. Inside, a battery converts chemical energy into electrical energy, and on charge it does the reverse.
Part 1 · Cells
The primary cell: use once, then discard A cell : two different electrodes in an electrolyte ; a battery is several cells joined Electrons transfer from one material to the other until a potential difference builds up A dry primary cell gives about 1.5 V On load, electrons leave the negative terminal and return to the positive through the circuit The negative electrode is slowly eaten away : the cell goes “dead” Primary cells cannot be recharged
electrons
+ carbon rod paste electrolyte − zinc case slowly eaten away
≈ 1.5 V · cannot be recharged
Chapter 4 · Batteries
4
e-books by eatpl.in · © 2026 · Do not copy or distribute
A cell is the basic unit: two different electrode materials standing in a chemical called the electrolyte. The electrolyte encourages electrons to transfer from one electrode to the other, and they pile up until there is a potential difference between them, about one and a half volts in a common dry cell like a torch battery. When you connect a load, electrons flow out of the negative terminal, round the external circuit, and back into the positive terminal, while inside the cell the chemical transfer carries on to replace them. The price is that the negative electrode, here the zinc case, is slowly dissolved into the electrolyte. When it is used up the cell is dead and must be thrown away. That is a primary cell: its chemical change cannot be reversed, so it cannot be recharged. Strictly, a battery is a group of cells joined together, though we use the word loosely.
Part 1 · Cells
The secondary cell: discharge and recharge Same principle, but the chemical change is reversible Discharge : chemical energy → electrical energy, current flows out to the loadCharge : a charger at a slightly higher voltage drives current the opposite way through the cellElectrical energy is stored again as chemical energy Hundreds of cycles over a long life: every aircraft battery is a secondary battery
Discharge
+ −
chemical → electrical electrons
Charge
+ −
charger
electrical → chemical electrons
Chapter 4 · Batteries
5
e-books by eatpl.in · © 2026 · Do not copy or distribute
A secondary cell works on the same principle as a primary cell, but its chemical change can be reversed. Here is a lead-acid cell. The positive plate is lead peroxide, the negative plate is spongy lead, and both stand in an electrolyte of dilute sulphuric acid. Connect a load, here a lamp, and the cell discharges. Watch the electrons leave the negative plate, pass through the lamp and return to the positive plate. Chemical energy is becoming electrical energy. To recharge it, we connect a charger whose voltage is slightly higher than the cell’s own. Now the current is driven in the reverse direction through the cell, and the chemical change runs backwards, storing the electrical energy as chemical energy again. A secondary cell can go round this cycle hundreds of times, and every battery fitted to an aircraft is a secondary battery.
Part 1 · Capacity
Capacity: ampere hours Capacity = current × time, in ampere hours (Ah) Set by the area of the plates (the amount of active material): bigger cell, more capacity Voltage is set by the materials , not the size40 Ah: 40 A for 1 h (1-hour rate) or 4 A for 10 h (10-hour rate) Always quote the rate : faster discharge gives a little less in practice Aircraft batteries are normally rated at the 1-hour rate
Capacity = current × time
40 A 4 A 0
1 h 10 h
time (hours)
1-hour rate: 40 A × 1 h = 40 Ah
the usual rating for aircraft batteries
10-hour rate: 4 A × 10 h = 40 Ah
in practice a faster discharge gives
a little less than the rated capacity
Chapter 4 · Batteries
6
e-books by eatpl.in · © 2026 · Do not copy or distribute
How much a cell can deliver is its capacity, measured in ampere hours. It is simply current multiplied by time. A forty ampere hour battery should give forty amps for one hour, which is called the one-hour rate, or four amps for ten hours, the ten-hour rate. Both rectangles on the graph have the same area. What decides capacity? The area of the plates, or really the amount of active material on them: a bigger cell holds more. Notice that the voltage of a cell does not depend on its size at all; it is set by the materials of the plates and electrolyte. Exam questions love that distinction. In practice, the faster you discharge a battery, the less of its rated capacity you actually get, so a capacity is always quoted with its rate. Aircraft batteries are normally rated at the one-hour rate.
Part 1 · Joining cells
Series adds volts; parallel adds ampere hours
Series: + to −
Parallel: + to +, − to −
12 V 40 Ah 12 V 40 Ah
+ −
24 V · 40 Ah
Volts add : 12 + 12 = 24 VCapacity stays that of one: 40 AhSame current flows through every cell
12 V 40 Ah 12 V 40 Ah
+ −
12 V · 80 Ah
Volts stay those of one: 12 VCapacities add : 40 + 40 = 80 AhThe load current is shared between them
Exam numbers: three 12 V 40 Ah batteries in series give 36 V, 40 Ah . Ten 2.2 V cells in parallel still give 2.2 V ; in series, 22 V .
Chapter 4 · Batteries
7
e-books by eatpl.in · © 2026 · Do not copy or distribute
Cells and batteries can be joined in two ways. In series, the positive of one goes to the negative of the next. The voltages add, so two twelve volt, forty ampere hour batteries give twenty-four volts. But the capacity stays at forty ampere hours, because the same current flows through every cell; each one is drained at the same rate as if it were alone. In parallel, all the positives are joined together and all the negatives together. Now the voltage is that of just one battery, twelve volts, but the capacities add up to eighty ampere hours, because the load current is shared between them. The cells inside an aircraft battery are in series, to build up the voltage; where an aircraft has two batteries they are usually in parallel. Try the classic examples: three twelve volt, forty ampere hour batteries in series make thirty-six volts and still forty ampere hours.
Part 2 · Lead-acid
Inside a lead-acid battery Positive plates: lead peroxide (brown); negative plates: spongy lead (grey)Electrolyte: dilute sulphuric acid (acid and distilled water) Plates interleaved with insulating separators , in a plastic or glass case Vent cap on each cell: lets out hydrogen, allows topping up with distilled water6 cells in series for 12 V, 12 cells for 24 VFound mainly in light aircraft ; free-liquid or absorbed-electrolyte types
+ −
vent caps: let hydrogen out 6 cells × 2 V in series = 12 V nominal
■ + lead peroxide■ − spongy lead■ dilute H₂SO₄
Chapter 4 · Batteries
8
e-books by eatpl.in · © 2026 · Do not copy or distribute
Here is a twelve volt lead-acid battery cut open. The plastic case is divided into six separate cells. In each cell the positive plates, coated with brown lead peroxide, are interleaved with negative plates of grey spongy lead, with thin insulating separators between them so they cannot touch. Several plates in each cell, all joined, give a large plate area and therefore a good capacity. The electrolyte is dilute sulphuric acid, kept just above the tops of the plates. On top, each cell has a vent cap, which lets out the hydrogen made during charging and is removed for topping up. Heavy cell links join the six cells in series, and at two volts each that makes twelve volts; a twenty-four volt battery has twelve cells. Lead-acid batteries are still found in many light aircraft, either with free liquid electrolyte or with the acid absorbed into the plates and separators, which makes spills much less likely.
Part 2 · Lead-acid
What happens on discharge and charge
Fully charged
Discharged
End of charge
+ lead peroxide (PbO₂) − spongy lead (Pb) SG 1.27 · 2.2 V off load
both plates → lead sulphate acid used up, water made SG 1.17 · 1.8 V on load
sulphate removed, acid restored then water splits: H₂ + O₂ gas “gassing”: water is lost
discharge
charge
PbO₂ + Pb + 2 H₂SO₄ ⇄ 2 PbSO₄ + 2 H₂O (discharge → , ← charge)
Discharge turns both plates to lead sulphate and the acid into water, so the specific gravity falls . Charging reverses it; gassing at full charge uses up water .
Chapter 4 · Batteries
9
e-books by eatpl.in · © 2026 · Do not copy or distribute
What actually changes inside a lead-acid cell? Fully charged, the positive plate is lead peroxide, the negative plate is spongy lead, and the acid is strong, with a specific gravity of about one point two seven. As the cell discharges, sulphate from the acid goes into both plates, turning them into lead sulphate, and water is made. So the acid becomes weaker, and when the specific gravity has fallen to about one point one seven, with the voltage on load down to one point eight, the cell should be recharged. Charging pushes current through the other way: the sulphate is driven out of the plates back into the acid, and the specific gravity rises again. Near full charge, the current starts to split water into hydrogen and oxygen, which bubble out. That is called gassing, and it is why a lead-acid battery slowly loses water, not acid.
Part 2 · Lead-acid
Specific gravity and the hydrometer Specific gravity (SG): density of the electrolyte compared with waterMeasured with a hydrometer : the float rides higher in stronger acid 1.27 fully charged; 1.17 discharged, time to rechargeFor lead-acid, SG shows the state of charge and serviceability Read the scale at the liquid surface , float clear of the walls
SG 1.27 charged
SG 1.17 flat
read the scale
at the liquid level
denser acid
lifts the float
Chapter 4 · Batteries
10
e-books by eatpl.in · © 2026 · Do not copy or distribute
Because the acid gets weaker as a lead-acid cell discharges, measuring its strength tells us the state of charge. The measure is specific gravity: the density of the electrolyte compared with pure water. The tool is a hydrometer. Squeeze the rubber bulb, put the nozzle in the cell and release it, and acid is drawn up into the glass barrel around a weighted float. Just as a ship floats higher in sea water than in fresh, the float rides higher in denser liquid. In strong, stronger acid, from a fully charged cell, it rides high and the scale reads about one point two seven. In weak, weaker acid, from a flat cell, it sinks lower and reads about one point one seven. You read the scale where it meets the liquid surface. So for a lead-acid battery, specific gravity is the standard test of state of charge and serviceability. Keep that thought, because it does not work for nickel-cadmium.
Part 2 · Lead-acid
Lead-acid cell voltages and cell counts Condition One cell 12 V battery (6 cells) 24 V battery (12 cells) Off load, fully charged (EMF) 2.2 V 13.2 V 26.4 V (reads ≈ 26 V)On load, nominal 2.0 V 12 V 24 V On load, discharged: recharge 1.8 V (SG 1.17)10.8 V 21.6 V Charging voltage (constant voltage) ≈ 2.33 V 14 V 28 V
The voltage of a cell is set by its materials ; the number of cells in series sets the battery voltage. 12 V needs 6 lead-acid cells.
Chapter 4 · Batteries
11
e-books by eatpl.in · © 2026 · Do not copy or distribute
Here are the lead-acid numbers to learn. One cell, fully charged and off load, has an E M F of about two point two volts. On load its nominal voltage is two volts, and when it has dropped to one point eight volts on load, it is discharged and needs recharging. A twelve volt battery has six cells in series, and a twenty-four volt battery has twelve. So a fully charged twenty-four volt battery, measured off load with everything switched off, reads about twenty-six volts, because twelve times two point two is twenty-six point four. Under load it settles near twenty-four. The bottom row is the charging voltage: the generator holds the bus at fourteen volts for a twelve volt battery, and twenty-eight volts for a twenty-four volt battery. And remember, if you join ten charged cells in parallel the open-circuit voltage is still only two point two volts.
Part 2 · Lead-acid
Charging, gassing and topping up Charge at a controlled rate : too fast causes violent gassing , boiling dry and plate damage Gassing loses water , so top up with distilled water , never acid Keep the electrolyte level just above the tops of the plates Non-spill vents let gas out but stop acid escaping in manoeuvres The gas is hydrogen : battery compartments are ventilated
hydrogen + oxygen out
level
plates
DISTILLED H₂O
top up with water,
never acid
charging too fast: violent gassing, boils dry
Chapter 4 · Batteries
12
e-books by eatpl.in · © 2026 · Do not copy or distribute
When charging a lead-acid battery the rate must be controlled. Charged too quickly, it gasses violently, the electrolyte heats and evaporates, and the battery can boil dry and buckle its plates. Even with correct charging, some gassing at full charge is normal, and what escapes is water broken into hydrogen and oxygen. So the acid itself is not lost, only water, and you top up with distilled water, never with acid. The correct level is just above the tops of the plates; exposed plates are damaged, and overfilling makes the acid spill out of the vents. The vents on aircraft batteries are non-spill vents: they let the gas out, but stop the electrolyte escaping during violent manoeuvres or inverted flight. Finally, the gas is hydrogen, which is explosive when mixed with air, so battery compartments are ventilated, often with a vent line overboard.
Part 2 · Lead-acid
Temperature and the risk of freezing Cold raises internal resistance : less current available, poorer cold starts Warmth lowers it: the battery performs better when warm A discharged cell has weak acid, mostly water: it can freeze SG 1.17 freezes near −18 °C ; SG 1.27 only near −62 °C In winter keep lead-acid batteries fully charged
Electrolyte freezing point
0 °C −20 °C −40 °C −60 °C 1.10 1.15 1.20 1.25
specific gravity of the electrolyte
flat, SG 1.17: ≈ −18 °C
charged, SG 1.27: ≈ −62 °C
Chapter 4 · Batteries
13
e-books by eatpl.in · © 2026 · Do not copy or distribute
Temperature matters a great deal to a lead-acid battery. In the cold, the chemical reactions slow down and the internal resistance rises, so the battery cannot deliver as much current, which is why cold engine starts are hard work. In warm conditions the internal resistance is lower and the battery performs better, just like a car battery on a summer morning. There is a second cold-weather danger. As a lead-acid cell discharges, its acid turns more and more into water, and water freezes much more readily than strong acid. Look at the graph. A fully charged cell, at specific gravity one point two seven, will not freeze until roughly minus sixty degrees. A flat cell, at one point one seven, can freeze at around minus eighteen, and freezing can crack the case and wreck the plates. So in winter operations, keep lead-acid batteries fully charged.
Part 2 · Safety
Handling electrolyte safely Corrosive Both electrolytes attack skin, eyes, aluminium alloy and wiring. Spills can do extensive structural damage .
Acid spill Neutralise lead-acid (sulphuric acid) with sodium bicarbonate (bicarbonate of soda) and water.
Alkali spill Neutralise Ni-Cd (potassium hydroxide) with a weak acid such as boric acid solution.
Never mix Keep lead-acid and Ni-Cd separate : separate tools, rooms and hydrometers. Acid fumes ruin Ni-Cd cells.
Hydrogen Charging gives off explosive hydrogen : ventilate, no sparks or flames nearby.
Protection Wear goggles, gloves and apron; wash splashes off with plenty of clean water .
Secure Batteries are clamped in vented boxes so they cannot shift or spill in turbulence.
Storage Store lead-acid charged (prevents sulphation); Ni-Cd can be stored discharged .
Chapter 4 · Batteries
14
e-books by eatpl.in · © 2026 · Do not copy or distribute
Battery electrolytes are dangerous, so handle them with care. Both kinds are highly corrosive: they burn skin and eyes, and spilt electrolyte can eat into aluminium alloy structure and wiring, doing extensive damage. Lead-acid batteries contain sulphuric acid, so a spill is neutralised with an alkali, a solution of sodium bicarbonate, bicarbonate of soda, in water. Nickel-cadmium batteries contain potassium hydroxide, an alkali, so it is neutralised with a weak acid such as boric acid. Never mix the two types: keep separate tools, hydrometers and charging rooms, because even acid fumes will ruin nickel-cadmium cells. Charging gives off hydrogen, so ventilate well and keep sparks and flames away. Wear goggles, gloves and an apron, and wash any splash off with plenty of clean water. And in the stores, lead-acid batteries are kept charged to stop sulphation, while nickel-cadmium batteries can be stored discharged.
Part 3 · Nickel-cadmium
The nickel-cadmium (alkaline) cell Positive : nickel hydroxide (nickel oxide); negative : cadmium Electrolyte: potassium hydroxide solution, an alkali ; SG 1.24 to 1.30 About 1.2 V per cell on load; 20 cells make a 24 V battery Low internal resistance : very high currents for starting, steady voltageRobust, long-lived, and can be stored discharged The usual battery on larger and turbine aircraft
+ nickel hydroxide − cadmium separator electrolyte: potassium hydroxide SG 1.24–1.30 vent
1.2 V per cell · 20 cells ≈ 24 V
Chapter 4 · Batteries
15
e-books by eatpl.in · © 2026 · Do not copy or distribute
Most larger aircraft use the nickel-cadmium battery, often called Ni-Cad, an alkaline battery. Its positive plates are nickel hydroxide, sometimes called nickel oxide, and its negative plates are cadmium. The electrolyte is a solution of potassium hydroxide in distilled water, an alkali, with a specific gravity of about one point two four to one point three zero. Each cell gives about one point two volts on load, so a twenty-four volt battery needs twenty cells. Why is it preferred? Its internal resistance is very low, so it can deliver the enormous currents needed to start a turbine engine without its voltage collapsing, and it can accept a charge without violent voltage swings. It is robust, has a long life, and it can be stored discharged without harm, so its shelf life is long. Its weaknesses are cost, and one serious hazard called thermal runaway, which we meet shortly.
Part 3 · Nickel-cadmium
Why a hydrometer is useless on a Ni-Cd The electrolyte takes no part in the reaction: its SG does not change Terminal voltage stays near 1.2 V almost all the way down So neither SG nor voltage shows the state of charge Only a measured discharge , a capacity test , tells you Electrolyte level is lowest when discharged : adjust it only when fully charged
Lead-acid
Nickel-cadmium
SG on discharge 1.27 → 1.17 shows state of charge
SG on discharge no change tells you nothing
voltage on discharge falls steadily
voltage on discharge almost constant
electrolyte level steady; top up when needed
electrolyte level lowest when discharged: adjust only when fully charged
charged flat charged flat
Chapter 4 · Batteries
16
e-books by eatpl.in · © 2026 · Do not copy or distribute
Here is a big difference from lead-acid. In a nickel-cadmium cell, the electrolyte only carries the charge between the plates; it takes no real part in the chemical change. So its specific gravity does not change as the cell discharges, and a hydrometer tells you nothing about the state of charge. The voltage does not help much either, because it stays close to one point two volts for nearly the whole discharge. The only reliable way to find out how much charge, or how much capacity, is left is a measured discharge, in other words a capacity test in the workshop. One more practical point. The electrolyte is partly absorbed into the plates as the cell discharges, so the level is lowest when the battery is flat and highest when fully charged. Topping up a flat Ni-Cd would make it overflow on charge, so the level is checked and adjusted only when the battery is fully charged.
Part 3 · Comparing discharge
Flat versus falling: the two discharge curves
80% 85% 90% 95% 100% 105% 110% 0% 25% 50% 75% 100%
charge used (per cent of capacity)
cell voltage on load (% of nominal)
Nickel-cadmium: flat near 1.2 V (≈1.21 V at half charge), then a sharp knee
Lead-acid: falls steadily from about 2.1 V to about 1.8 V (recharge point)
both: recharge now
nominal
The Ni-Cd holds a much steadier voltage during discharge, which is why it is preferred for emergency power after a generator failure.
Chapter 4 · Batteries
17
e-books by eatpl.in · © 2026 · Do not copy or distribute
This graph compares how the two types behave as they discharge, with each voltage shown as a percentage of its own nominal value. The lead-acid line in brown falls steadily the whole way, from about two point one volts at the start down to about one point eight volts when it should be recharged. You can watch its state of charge on the voltmeter. The nickel-cadmium line in blue is almost flat. After a small dip at the start it sits close to one point two volts until roughly ninety per cent of its charge is gone, and then it drops off a cliff. That flat curve is exactly why the Ni-Cd is preferred on large aircraft: after a total generator failure it supplies a far more stable voltage to the essential instruments and radios. The catch is the cliff. A Ni-Cd gives very little warning before it is exhausted, which is one more reason the capacity test matters.
Part 3 · Thermal runaway
Thermal runaway Ni-Cd cells have low thermal capacity : heat builds faster than it escapes Heat lowers internal resistance , so on constant-voltage charge the current rises More current, more heat, lower resistance: a vicious circle Unchecked: boiling electrolyte, fire, even explosion and total destruction Triggers: high charge rate, a weak or old cell, high ambient temperature, repeated starts
Charge current ↑ cells heat up Temperature ↑ low thermal capacity Resistance ↓ internal, falls with heat
unchecked: boils, burns, may explode
thermal switch opens charger off + BAT OVHT warning
Chapter 4 · Batteries
18
e-books by eatpl.in · © 2026 · Do not copy or distribute
Thermal runaway is the hazard every pilot must understand about nickel-cadmium batteries. These cells have a low thermal capacity, so under some conditions they make heat faster than they can lose it. Here is the trap. As a Ni-Cd heats up, its internal resistance falls. If it is being charged from a fixed voltage, a lower resistance lets more charging current flow. Watch the charging current grow and the cells heat. More current makes more heat, the heat lowers the resistance further, and the current climbs faster still. It is a vicious circle. Left unchecked, the electrolyte boils, the cells can catch fire and the battery may even explode, destroying itself and damaging the aircraft. That is why the battery has a thermal switch: when the temperature reaches a set value, it opens and disconnects the battery from the charger, breaking the loop, and the gauge falls back again.
Part 3 · Thermal runaway
Protection and Ni-Cd charging A thermal switch or sensor in the battery isolates it from the charge at a pre-set temperature It resets when the battery cools; a BAT OVHT or temperature warning alerts the crew Many Ni-Cd installations use a dedicated charger with constant current charging It watches temperature and voltage ; pulse charging above about 85% of capacity Crew action on a warning: battery off charge or off line, as the checklist says
Battery charger constant current, pulses above ≈ 85%
sensor
contactor
temperature and voltage sensing
BAT OVHT
flight-deck warning
Chapter 4 · Batteries
19
e-books by eatpl.in · © 2026 · Do not copy or distribute
How is thermal runaway prevented? First, a thermal switch or temperature sensor sits among the cells. When the temperature reaches a pre-set value, it isolates the battery from the charging source, and only when the battery has cooled does it reconnect. A warning light, such as battery overheat, or a temperature gauge tells the crew, who then follow the checklist, normally taking the battery off charge. Second, because a Ni-Cd on a fixed charging voltage is the very setup that allows runaway, many installations do not simply float the battery on the bus. Instead, a dedicated battery charger supplies a controlled, constant current while it monitors the battery temperature and voltage. Some chargers use pulse charging: once the battery is up to about eighty-five per cent of its capacity, the charger stops feeding a steady current and delivers short pulses instead, topping it up without overheating it.
Part 4 · Checks
The capacity test and the 80% rule Rated capacity : maker’s figure, e.g. 60 Ah at the 1-hour rateActual capacity falls with age: found by a measured discharge Efficiency = actual ÷ rated × 100% Done every 3 months ; must be 80% or more to stay in service Ensures essential loads for about 30 minutes after generator failure
Capacity test: 60 Ah battery at 60 A
80% limit
lasted 42 min
full bar = 60 min (rated)
Actual capacity = 60 A × 0.7 h = 42 Ah
Efficiency = 42 ÷ 60 = 70%
Below 80%: remove from service
Why 80%? After all generators fail, thebattery must carry the essential loads (attitude, essential radio, lighting, pitot heat) for about 30 minutes . Test every 3 months .
Chapter 4 · Batteries
20
e-books by eatpl.in · © 2026 · Do not copy or distribute
Every battery loses capacity as it ages, so its actual capacity is checked by a capacity test. The battery is fully charged, then discharged at its rated load, and timed. Take a sixty ampere hour battery rated at the one-hour rate. It should supply sixty amps for one hour. Suppose it lasts only forty-two minutes, which is point seven of an hour. Its actual capacity is sixty times point seven, forty-two ampere hours, and its efficiency is forty-two divided by sixty, seventy per cent. The rule is that the capacity test is done every three months, and the efficiency must be eighty per cent or more for the battery to stay in service. So this battery is rejected. Why eighty per cent? Because the battery must still be able to carry the essential loads, such as attitude information, essential radio, lighting and pitot heat, for about thirty minutes after the generators fail.
Part 4 · Checks
On-load checks: the voltmeter tells the truth under load Battery voltage is checked with a voltmeter with the rated load ON Off load, even a weak battery shows its full EMF (≈ 26 V for 24 V lead-acid) Pre-flight: note off-load volts, switch on loads (pitot heat, lights, blowers) Voltage holds above the stated value: good; sinks below it: low charge Workshop on-load check: rated load for 10 to 20 seconds
0 10 20 30 26 V
off load 0 10 20 30 24 V
rated load ON
Holds steady above the stated value: good charge
Sinks below the limit within the time: low, replace
Workshop on-load check: rated load for10–20 seconds on modern types
Chapter 4 · Batteries
21
e-books by eatpl.in · © 2026 · Do not copy or distribute
Why is battery voltage always checked on load? Because a voltmeter across a battery with nothing switched on measures its E M F, and even a tired battery will show a healthy-looking figure, about twenty-six volts for a twenty-four volt lead-acid battery. The truth only appears when current flows, because a weak battery has a high internal resistance and its terminal voltage sags. So the rule is: check with a voltmeter, with the rated load switched on. On a pre-flight check you may compare the off-load reading with the reading after switching on selected loads such as pitot heat, landing lights and blower motors. If the voltage holds steady above the stated figure, the battery is in a good state of charge. If it sinks below the stated value within the time given in the manual, the battery is low and should be replaced. In the workshop, the rated load is applied for just ten to twenty seconds.
Part 4 · Charging
Charging in flight and the battery ammeter Constant-voltage charging: the generator holds the bus 2 V above the battery per 12 V12 V battery: 14 V bus; 24 V battery: 28 V bus Battery is in parallel with the loads; battery master OFF isolates it from the bus After a battery start: high charge at first, falling quickly to a trickle Charge that stays high or rises : suspect a faulty battery, risk of overheating
Battery ammeter after engine start
0 10 20 30 0 A 20 A 40 A 60 A 80 A
minutes after the generator comes on line
healthy: high, then falls to a trickle
faulty: stays high or rises
Chapter 4 · Batteries
22
e-books by eatpl.in · © 2026 · Do not copy or distribute
In flight, most aircraft keep the battery charged by the constant-voltage method. The generator holds the bus bar at a fixed voltage a little above the battery’s own, two volts higher for every twelve volts of battery. So the bus runs at fourteen volts for a twelve volt battery, and twenty-eight volts for a twenty-four volt battery. The battery sits across the bus in parallel with the loads, and switching the battery master off simply isolates it from the bus. Now watch the centre-zero ammeter after an engine start. The start drained the battery, so when the generator comes on line the charging current is high, and then, as the battery recovers and its voltage rises, the current falls away to a trickle. That is a healthy battery. If the charge rate stays high, or starts to rise again, suspect a faulty battery: it could overheat, and on a Ni-Cd that is the road to thermal runaway.
Side by side
Lead-acid versus nickel-cadmium Lead-acid Nickel-cadmium Plates (+ / −) Lead peroxide / spongy lead Nickel hydroxide / cadmium Electrolyte Dilute sulphuric acid Potassium hydroxide (alkali)SG 1.27 charged, 1.17 flat: shows charge1.24–1.30 , constant: shows nothingCell voltage 2.2 V off load, 2.0 V nominal, 1.8 V flat 1.2 V , almost constantCells for 24 V 12 20 State of charge Hydrometer or on-load voltage Capacity test (measured discharge)Spill neutraliser Sodium bicarbonate Boric acid Storage / hazard Store charged ; freezes if flat Can store discharged ; thermal runaway
Chapter 4 · Batteries
23
e-books by eatpl.in · © 2026 · Do not copy or distribute
Here are the two types side by side, which is how many exam questions are set. Lead-acid has lead peroxide and spongy lead plates in sulphuric acid; nickel-cadmium has nickel hydroxide and cadmium plates in potassium hydroxide, an alkali. For lead-acid the specific gravity goes from one point two seven charged to one point one seven flat, so it shows the state of charge. For the Ni-Cd it stays between one point two four and one point three zero whatever the charge, so it shows nothing. A lead-acid cell is two volts nominal, two point two off load and one point eight when flat; a Ni-Cd cell is one point two volts, almost constant. So twenty-four volts takes twelve lead-acid cells but twenty Ni-Cd cells. Neutralise acid with sodium bicarbonate and alkali with boric acid. Store lead-acid charged, Ni-Cd discharged if you like, and remember thermal runaway belongs to the Ni-Cd.
Summary
What to take into the exam Cells Primary 1.5 V, not rechargeable. Secondary: reversible. Voltage set by materials; capacity by plate area.
Series / parallel Series: volts add, Ah same. Parallel: volts same, Ah add. 2 × 12 V 40 Ah series = 24 V 40 Ah.
Lead-acid PbO₂ / Pb, H₂SO₄. 2.2 off load, 2.0 nominal, 1.8 flat. SG 1.27 → 1.17. 6 cells = 12 V.
Servicing Level just above plates; top up with distilled water; non-spill vents; bicarbonate for acid.
Ni-Cd KOH, SG 1.24–1.30 constant, 1.2 V flat discharge, low resistance. Charge only shown by capacity test.
Thermal runaway Heat → lower resistance → more charge current → more heat. Thermal switch isolates charge.
Capacity test Every 3 months, at least 80%: essential loads for 30 min. 60 Ah lasting 42 min = 70%: reject.
Checks and charging Voltmeter on rated load. Constant voltage: 28 V bus for 24 V. High charge after start should fall.
Chapter 4 · Batteries
24
e-books by eatpl.in · © 2026 · Do not copy or distribute
Let us pull it all together. A primary cell gives about one and a half volts and cannot be recharged; a secondary cell can. Cell voltage is set by the materials, capacity by the plate area. In series volts add and ampere hours stay the same; in parallel volts stay the same and ampere hours add. Lead-acid: lead peroxide and spongy lead in sulphuric acid, two point two volts off load, two nominal, one point eight flat, specific gravity one point two seven down to one point one seven, six cells for twelve volts. Keep the level just above the plates and top up with distilled water. Nickel-cadmium: potassium hydroxide, constant specific gravity, a flat one point two volts per cell, and its charge is only shown by a capacity test. Beware thermal runaway. Capacity is tested every three months and must be at least eighty per cent. Check voltage on load, and expect a high charge after a start that quickly falls away.