Electrics · Chapter 9
Bonding and Screening How an aircraft deals with static electricity and electrical noise: bonding straps, static wicks, conductive tyres, refuelling bonds and screened cables.
static wicks · bonding · screening © 2026 eatpl.in. For the personal study of eatpl.in students only. Do not copy or distribute.
e-books by eatpl.in · © 2026 · Do not copy or distribute
Chapter nine is short but it comes up in every exam. An aircraft flying through rain, snow and cloud picks up static electricity, and if different parts of it end up at different voltages, a spark can jump between them, with fuel vapour nearby. Bonding stops that by tying every part together electrically. We will also look at static wicks, conductive tyres, the bonding drill for refuelling and lightning strikes, and finally screening, which stops electrical equipment from filling the radios with noise.
Roadmap
Static, sparks and noise 1 · The problem How the aircraft charges up in flight, and why a potential difference means sparks.
2 · Bonding Bonding straps , clean joints, primary and secondary bonds, and what bonding is for .
3 · Getting rid of charge Static wicks , conductive tyres , refuelling bonds and lightning.
4 · Screening Stopping equipment from interfering with the radios : suppressors and metal sheaths.
Chapter 9 · Bonding and Screening
2
e-books by eatpl.in · © 2026 · Do not copy or distribute
This chapter is about static electricity and electrical noise. Part one describes the problem: how an aircraft builds up a static charge in flight, and why a difference in potential between two parts of the aircraft is dangerous. Part two is bonding, the cure: the straps that join every part of the aircraft together electrically, how they must be fitted, and the other jobs bonding does for us. Part three covers how the charge is got rid of: static wicks in flight, conductive tyres at touchdown, the bonding procedure for refuelling, and what happens in a lightning strike. Part four is screening, which is a different thing: it stops electrical equipment on board from interfering with the radios.
Part 1 · The problem
How an aircraft becomes charged An aircraft in flight picks up static electricity from the atmosphere Precipitation static : friction with rain, snow, ice crystals and dustAlso engine exhaust , and charged clouds nearby The charge can reach thousands of volts The air is a poor conductor, so the charge stays on the airframe until it can leak away Precipitation static (P-static) Rain, snow, ice crystals and dust rub the skin and leave a charge on the airframe Also: engine exhaust, charged clouds nearby, and lightning strikes
Chapter 9 · Bonding and Screening
3
e-books by eatpl.in · © 2026 · Do not copy or distribute
An aircraft in flight picks up static electricity from the atmosphere. The main cause is friction. As the aircraft flies through rain, snow, ice crystals or dust, the particles rub against the skin and carry electrons away, or leave them behind, rather like rubbing a balloon on your sleeve. This is called precipitation static. The engine exhaust also carries charge away, and flying close to strongly charged clouds induces charge on the airframe too. Because the surrounding air is a poor conductor, the charge cannot easily escape, so it builds up until the aircraft is at a potential of many thousands of volts compared with its surroundings. That on its own is not the danger. The danger comes when different parts of the aircraft end up at different potentials.
Part 1 · The problem
Why a potential difference is dangerous If two parts are at different potentials , a spark can jump between them A spark near fuel vapour is a serious fire risk Sparks also cause radio interference Worked example: 100 pF at 5000 V stores 1.25 mJ Fuel vapour can ignite with about 0.2 mJ : six times less structure 0 V unbonded panel 5000 V spark fuel vapour nearby Energy in the spark: E = ½ C V² C ≈ 100 pF (100 × 10⁻¹² F), V = 5000 V E = 0.5 × 100 × 10⁻¹² × 5000² = 1.25 mJ Fuel vapour can ignite with about 0.2 mJ → about 6 × the energy needed: a real fire risk Bonded: no potential difference, so no spark
Chapter 9 · Bonding and Screening
4
e-books by eatpl.in · © 2026 · Do not copy or distribute
Static becomes dangerous when one part of the aircraft is at a different potential from the part next to it. Picture a panel or a control surface that is not electrically connected to the main structure. The charge on it builds up, and once the voltage across the small gap is high enough, a spark jumps. If that happens near fuel vapour, for example close to a tank vent or a fuel pipe joint, the spark can start a fire. Let us check the energy. A small isolated part might have a capacitance of about one hundred picofarads. Charged to five thousand volts, it stores half C V squared, which works out at one point two five millijoules. Fuel vapour can be ignited by as little as about zero point two millijoules, so this one spark has about six times the energy needed. Every spark is also a burst of radio noise.
Part 2 · Bonding
What bonding is Every piece of metal structure and every component is joined to the next Joined by flexible strips of braided copper (bonding straps or jumpers) Gives electrons an easy path from one part of the aircraft to another So the whole aircraft is kept at the same potential : no sparks Especially across hinges , rubber mountings and flexible pipe joints Control surface hinge wing aileron strap bridges the hinge Engine on rubber mountings engine rubber isolates the engine electrically: a strap is needed Pipe joint with a flexible hose rubber hose fuel / oil lines
Chapter 9 · Bonding and Screening
5
e-books by eatpl.in · © 2026 · Do not copy or distribute
Bonding is the cure. Every piece of metal structure, and every component fitted to the aircraft, is joined electrically to the next by flexible strips, usually braided copper, called bonding straps or jumpers. That gives electrons an easy, low-resistance path from any part of the aircraft to any other, so charge spreads out evenly and the whole aircraft sits at the same potential. With no difference in potential there is nothing to drive a spark. Look at where straps are needed most. A control surface hangs on hinges, and greased bearings are a poor electrical path, so a strap bridges the hinge. An engine sits on rubber anti-vibration mountings that insulate it completely, so it needs straps too. And a fuel or oil pipe joined by a flexible rubber hose must have a strap across the joint. Exam wording: bonding keeps all parts at the same potential.
Part 2 · Bonding
A bonding strap across a hinge A hinge is a poor electrical path: grease, bearings, small contact areas Without a strap the control surface charges separately The potential difference grows until a spark crosses the hinge A braided strap lets charge flow across: both parts at 0 V difference The strap is flexible , so the surface still moves freely Without a strap wing 0 V aileron 5000 V + + + + + Potential difference: spark across the hinge With a bonding strap wing 0 V aileron 0 V Same potential: no spark, no radio crackle
Chapter 9 · Bonding and Screening
6
e-books by eatpl.in · © 2026 · Do not copy or distribute
Here is the most common bonding strap of all, across a control surface hinge. The wing is fixed structure. The aileron hangs on hinges, and a hinge is a poor electrical path: the bearings are greased and the contact area is tiny. So in precipitation the aileron charges up separately. The gauge shows the potential difference between the two growing to thousands of volts, until a spark jumps across the hinge gap, with a crack in the radios each time. Now we fit a bonding strap, a short length of flexible braided copper bolted to clean metal on each side. Charge flows freely across it, the potential difference falls to zero, and the sparking stops. Because the strap is flexible and has a little slack, the aileron still moves through its full travel.
Part 2 · Bonding
Clean joints, low resistance Strap ends must sit on clean bare metal Remove anodising , paint , grease and oxides under the terminal Otherwise the joint has resistance , and moisture brings electrolytic corrosion Corrosion raises the resistance further, and the bond fails After fitting, the joint is protected again against corrosion Making a good bond braided strap paint primer / anodising bare, clean metal under the lug aluminium skin Remove first anodising, paint, grease, oxides, sealant then protect after fitting If not high resistance joint electrolytic corrosion resistance rises further
Chapter 9 · Bonding and Screening
7
e-books by eatpl.in · © 2026 · Do not copy or distribute
A bonding strap is only as good as its two joints. The terminal at each end must sit on clean, bare metal. Aircraft aluminium is normally anodised, primed and painted, and every one of those layers is an insulator, so they must be removed under the terminal, together with any grease and the thin oxide film that forms on aluminium. If they are left, the joint has a high resistance from the start. Worse, if moisture gets into a poor joint between different metals, electrolytic corrosion begins, and the corrosion products add even more resistance until the bond is useless. So the rule is simple: clean metal, no insulating coatings, no chance for corrosion to add resistance. Once the strap is fitted and tested, the joint is sealed or painted over to keep moisture out.
Part 2 · Bonding
What bonding does for us Same potential All parts at the same potential , so static cannot spark between them: fire protection.
Earth return A low-resistance return path for the single-pole (earth-return) electrical system.
Radio interference No small static discharges at joints, so less radio noise .
Lightning Lets lightning currents and local static charges pass safely through the structure.
People Crew and passengers cannot get a shock from parts at different potentials.
Exam answer "To provide a low resistance path for earth return circuits and safely dissipate local static charges and lightning strikes ."
Chapter 9 · Bonding and Screening
8
e-books by eatpl.in · © 2026 · Do not copy or distribute
Bonding does several jobs at once. First, the main one: it keeps every part of the aircraft at the same potential, so static cannot spark from one part to another, which protects against fire. Second, it forms part of the earth return for the single-pole electrical system we met in the last chapter; the return current from every load flows through the bonded structure. Third, because there are no tiny sparks at poorly connected joints, there is much less radio interference. Fourth, it gives lightning current and local static charges a safe path through the structure. And it protects people from shocks. If an exam question asks for the purpose of bonding, the best answer is the full one: to provide a low resistance path for earth return circuits and to dissipate local static charges and lightning strikes safely.
Part 2 · Bonding
Primary and secondary bonding Primary bonding Secondary bonding Joins Major structure: wings, fuselage sections, tail, engines, control surfaces Equipment, pipes, panels and brackets to the structure Must carry Lightning and heavy earth-return currentsStatic charges and small currents Conductor Heavy, large cross-section straps Lighter straps or jumpers Resistance Very low : typically a few hundredths of an ohmLow : typically up to about an ohmChecked by A bonding tester (a low-resistance ohmmeter) during maintenance The same tester Poor bond shows as Static noise on the radios , arcing, faulty earth returnsRadio noise, local sparking
Exact limits are set by each aircraft's maintenance manual; pilots need the principle: the lower the resistance, the better the bond .
Chapter 9 · Bonding and Screening
9
e-books by eatpl.in · © 2026 · Do not copy or distribute
Bonds come in two grades. Primary bonding joins the major parts of the structure: wing to fuselage, fuselage sections to one another, the tail, the engines and the control surfaces. These bonds must be able to carry a lightning strike and the heavy earth-return currents, so they use large straps and their resistance must be very low, typically just a few hundredths of an ohm. Secondary bonding connects equipment, pipes, panels and brackets to the structure. These only need to carry static charges and small currents, so lighter jumpers are used, with a low resistance, typically up to about an ohm. Engineers check bonds with a bonding tester, which is really a sensitive low-resistance ohmmeter. Exact limits come from the maintenance manual for each type. For you as a pilot, the important point is that a poor bond usually shows up as static noise on the radios.
Part 2 · Faults
The signs of poor bonding Classic symptom: static interference on the radios Tiny sparks at the bad joint each time charge jumps across Faulty earth returns : dim lights, erratic instruments, motors that stallCorrosion and burning at the jointGreater damage if lightning strikes Good bonding: clean audio Poor bonding: static crackle Tiny discharges at bad joints = noise in the receivers
Chapter 9 · Bonding and Screening
10
e-books by eatpl.in · © 2026 · Do not copy or distribute
How would you know a bond had failed? The classic symptom, and the one examiners ask about, is static interference on the radios: crackling and hissing that gets worse in rain or snow. Each time enough charge builds up on the poorly bonded part, it jumps the gap as a tiny spark, and every spark is a burst of radio-frequency energy that the receivers pick up as a click. The graph shows the idea: clean audio on top, the same signal with sharp spikes below. A bad bond in the earth-return path also adds resistance to every circuit that returns through it, so lights may be dim, instruments may read wrongly and motors may run slowly. The joint may also show burning or corrosion. And if lightning strikes, a poor bond is where the current will arc, causing damage. Remember: poor bonding, think radio noise.
Part 3 · Static wicks
Where the static wicks are Static wicks Trailing edges of the wings, near the tips Tips and trailing edges of the tailplane and fin Charge leaks away gently into the air from sharp points, well away from aerials Purpose: reduce static build-up and so minimise radio interference Fitted at trailing edges and tips of wings, tailplane and fin: the points where charge naturally leaves the aircraft.
Chapter 9 · Bonding and Screening
11
e-books by eatpl.in · © 2026 · Do not copy or distribute
Bonding makes the whole aircraft one conductor at one potential, but the charge still has to go somewhere. Static wicks, also called static dischargers, let it leak away into the air in flight. They are fitted along the trailing edges of the wings near the tips, at the tips and trailing edges of the tailplane, and at the top of the fin. Why there? Charge on a conductor crowds towards sharp edges and points, and the trailing edges and tips are where it would naturally try to leave the aircraft anyway. A wick gives it a controlled place to do so, well away from the radio aerials. Each wick is bonded to the structure at its base, and the charge leaves from its free end. You will see a row of them, often five or six on each wing, on almost every airliner.
Part 3 · Static wicks
How static wicks work Charge collects at sharp points and leaks away as a quiet brush (corona) discharge Many gentle discharges instead of sudden sparks near the aerials Purpose: reduce static build-up and so minimise radio interference Original type: cotton , about as thick as a cigarette, with a "teased" free end Modern types: miniature wire brushes , barbed aerial-like wicks, or straight metal rods Types of wick cotton, "teased" end (original type) wire brush (miniature barbed aerial) straight rod (sharp tip) All fitted to trailing edges and tips; the base is bonded to the structure Discharge from the free end into the air Why points work charge crowds at the sharp tip and leaks off as a quiet brush (corona) discharge
Chapter 9 · Bonding and Screening
12
e-books by eatpl.in · © 2026 · Do not copy or distribute
A static wick works because charge on a conductor crowds towards sharp points. At the fine tip of a wick the electric field becomes strong enough to ionise the air around it, and charge leaks away continuously as a quiet brush, or corona, discharge. So instead of the charge building up and escaping in sudden, noisy sparks somewhere near an aerial, it trickles off gently at the trailing edges. That is why the exam answer for the purpose of static wicks is to minimise radio interference. The first wicks were lengths of cotton, about as thick as a cigarette, whose free end became teased, or frayed out, in the airflow, giving many fine points. Modern wicks are miniature wire brushes, barbed wicks that look like tiny aerials, or straight metal rods with a sharp tip. Damaged or missing wicks are a common cause of radio noise in precipitation.
Part 3 · Landing
Getting rid of the charge at touchdown Some charge is still on the aircraft at landing : a fire risk on the ground The main bond must touch earth the instant the aircraft lands Done with conductive tyres : rubber with a high carbon content Path: airframe → leg → axle → wheel bearings → wheel → tyre → runway Nose, main or tail wheel tyres can be used airframe: charged in flight runway main bond down the leg axle and wheel bearings conductive tyre: high carbon content in the rubber Charge goes to earth the instant the tyres touch
Chapter 9 · Bonding and Screening
13
e-books by eatpl.in · © 2026 · Do not copy or distribute
Even with wicks, some charge is still on the aircraft when it lands. If it stayed there, the first person to touch the aircraft, or the first fuel hose connected, could draw a spark. So the main bond must be brought into contact with earth at the instant of touchdown. This is done with conductive tyres. The rubber of the nose, main or tail wheel tyres contains a high proportion of carbon, which makes it a conductor. The charge on the airframe has a path through the main bond, down the gear leg, through the axle and the wheel bearings into the wheel, and out through the tyre into the runway. So the moment the tyres touch, the charge goes to earth and is dissipated. Older aircraft sometimes trailed a short earthing wire or strap for the same reason.
Part 3 · On the ground
Bonding for refuelling Fuel flowing through a hose generates static The aircraft and the bowser are bonded together and earthed first The nozzle is bonded to the aircraft tank before the filler cap is opened So no spark can occur where the fuel vapour is Disconnect the bonds last , in the reverse order aircraft wing tank BOWSER hose 2 nozzle bonded to the tank before the cap is opened 1 bowser bonded to aircraft earth earth Earth everything, bond bowser to aircraft, then bond the nozzle to the tank BEFORE opening the filler cap. Disconnect in the reverse order.
Chapter 9 · Bonding and Screening
14
e-books by eatpl.in · © 2026 · Do not copy or distribute
Refuelling brings the danger closest. Fuel moving quickly through a hose and filter generates static of its own, and the vapour is right there at the open filler. So before any fuel flows, the aircraft and the bowser are bonded together with a bonding cable, and both are connected to earth, so all three are at the same potential. Then, for over-wing refuelling, the nozzle is bonded to the aircraft fuel tank with its own small lead before the filler cap is opened. That way, if any charge has built up on the nozzle or hose, it flows away through the bond and not as a spark across the gap between the nozzle and the filler neck, where the vapour is richest. When refuelling is finished, the bonds are removed last, in the reverse order. Exam answer: the refuelling nozzle must be bonded to the fuel tank.
Part 3 · Lightning
Bonding and lightning strikes Lightning usually enters at an extremity (nose, wing tip) and leaves at another (tail, fin) The current flows through the skin and structure ; the occupants are protected inside Good primary bonding gives a continuous, low-resistance path Poor bonds make the current arc across joints or flow through pipes and systems Composite parts need a built-in conductive mesh or foil entry: nose exit: fin tip current flows through the bonded skin Bonding gives lightning a continuous, low-resistance path • heavy primary bonds across major joints and hinges • no arcing at joints, no current through pipes and systems • composite panels need a conductive mesh or foil layer
Chapter 9 · Bonding and Screening
15
e-books by eatpl.in · © 2026 · Do not copy or distribute
Lightning is static on a giant scale, and bonding is what makes a strike survivable. A strike usually attaches at an extremity, such as the nose, a wing tip or an engine nacelle, and leaves from another, often the tail or the fin. In between, the current flows along the outside of the aircraft through the skin and structure, and the people inside, sitting in a metal tube, are protected. For that to work, the path must be continuous and of low resistance. That is the job of the heavy primary bonds across every major joint, hinge and engine mounting. If a bond is poor, the current will arc across the joint, burning and pitting it, or find another path through pipes, cables and systems. Composite structure does not conduct well, so composite panels have a conductive mesh or foil built into them, bonded to the rest of the structure.
Part 4 · Screening
Screening against radio interference Screening prevents radio interference by absorbing electrical energyEquipment that makes and breaks circuits or sparks produces electrical noise Cure 1: suppressors in the cables connected to the source Cure 2: total enclosure of the cables in a continuous metal sheath (braid) The screen is earthed to the structure, so absorbed energy goes to earth copper conductor insulation metal braid screen outer sheath screen earthed unscreened end: radiates screened: energy absorbed and taken to earth Plus suppressors (capacitors, filters) in the leads at the source
Chapter 9 · Bonding and Screening
16
e-books by eatpl.in · © 2026 · Do not copy or distribute
Screening is a different job from bonding. Many electrical machines produce electrical noise as they work: wherever contacts make and break, or brushes spark on a commutator, short bursts of radio-frequency energy are generated, and these get into the radios as interference. Screening prevents radio interference by absorbing that energy before it can reach the receivers. There are two methods, usually used together. First, interference suppressors, mainly capacitors and filters, are fitted in the cables connected to the source of the noise. Second, the cables are totally enclosed in a continuous metal sheath, a braided screen. An unscreened lead radiates noise like a small transmitter. A screened lead does not: the braid absorbs the energy and, because it is earthed to the structure at its ends, carries it away to earth. An outer protective sheath covers the braid.
Part 4 · Screening
What must be screened Equipment Why it makes interference Ignition systems High-voltage sparks at the plugs, many times a second DC generators and motors (commutator machines)Brushes sparking as the commutator segments make and break contact Slip-ring machines running at over 200 rpm Brush contact noise at the rings Any equipment making and breaking a circuit at more than 10 Hz Each make or break is a burst of radio-frequency energy (e.g. flashers, vibrators, inverters)
Remember the numbers: slip rings over 200 rpm ; switching faster than 10 Hz .
Chapter 9 · Bonding and Screening
17
e-books by eatpl.in · © 2026 · Do not copy or distribute
Which equipment has to be screened? Learn this list, with its two numbers. First, ignition systems: magnetos and plugs make high-voltage sparks many times a second, and every spark is a little radio transmitter. Second, DC generators and motors, in other words commutator machines, because the brushes spark as the commutator segments make and break contact. Third, slip-ring machines such as alternators, when they run at more than two hundred revolutions per minute. And fourth, any electrical equipment that works by making and breaking a circuit at a frequency greater than ten hertz, such as flashing beacons, vibrators and some inverters. In each case the cure is the same: suppressors in the leads at the source, and the leads themselves enclosed in an earthed metal screen.
Part 4 · Screening
Suppressing noise at the source A capacitor across the brushes or supply leads absorbs the sparking energy The light aircraft system has a radio interference capacitor at the alternator Filters stop noise travelling along the power wiring Screens must be continuous and properly earthed Radio noise that changes with an engine or a motor points to a suppression or screening fault M C Capacitor across the brushes absorbs the sparking energy brush Without suppression With suppression noise on the supply line
Chapter 9 · Bonding and Screening
18
e-books by eatpl.in · © 2026 · Do not copy or distribute
Suppression deals with the noise at its source. The simplest suppressor is a capacitor connected across the brushes of a motor or generator, or between its supply lead and earth. Each time a brush breaks contact and tries to spark, the capacitor absorbs the burst of energy instead, and the spikes on the supply line almost disappear, as the two traces on the right show. You saw one of these in the light aircraft system diagram: the radio interference capacitor at the alternator. Filters, made of capacitors and small coils, stop noise from travelling along the power wiring to other equipment. And a screen only works if it is continuous along the cable and properly earthed. If you hear a whine in the headset that rises and falls with engine speed, or a buzz when a motor runs, suspect a failed suppressor or a broken screen.
Comparison
Bonding, wicks, tyres and screening Measure Purpose Where Exam key words Bonding Same potential everywhere; earth return; lightning path Every joint, hinge, mounting, pipe "same potential", "low resistance path" Static wicks Reduce static build-up; minimise radio interference Trailing edges and tips "brush discharge", "radio interference" Conductive tyres Discharge static on touchdown Nose, main or tail wheels "high carbon content" Refuelling bonds No spark at the filler Bowser, aircraft, earth, nozzle "nozzle bonded to the tank" Screening Prevent radio interference by absorbing energy Noisy equipment and its cables "suppressors", "metal sheath"
Chapter 9 · Bonding and Screening
19
e-books by eatpl.in · © 2026 · Do not copy or distribute
Before the summary, let us line the measures up so you do not mix them up in the exam. Bonding keeps every part at the same potential, provides the earth return, and gives lightning a path; its key words are same potential and low resistance path. Static wicks reduce the static build-up and so minimise radio interference, by brush discharge at the trailing edges and tips. Conductive tyres, with a high carbon content, discharge the remaining static at touchdown. Refuelling bonds make sure no spark can occur at the filler, so the nozzle is bonded to the tank. And screening prevents radio interference by absorbing the energy produced by noisy equipment, using suppressors and continuous metal sheaths. Notice that three of the five are about radio interference as well as fire: that is why the radio answer comes up so often.
Summary
What to take into the exam Static charge Picked up in flight from precipitation, dust and clouds. A potential difference between parts means sparks : fire risk and radio noise.
Bonding Flexible strips join every part: all at the same potential . Clean bare metal: no anodising, paint, grease or oxide.
Jobs of bonding No sparks; earth return path; less radio interference ; safe path for lightning .
Poor bonding Shows as static interference on the radios ; also faulty earth returns and corrosion.
Static wicks Trailing edges and tips. Brush discharge. Purpose: minimise radio interference .
Touchdown Conductive tyres (high carbon) earth the main bond via the wheel bearings.
Refuelling Bowser and aircraft bonded and earthed; nozzle bonded to the tank before opening.
Screening Absorbs energy to stop radio interference: suppressors + metal sheath. Ignition, commutator machines, slip rings > 200 rpm, switching > 10 Hz.
Chapter 9 · Bonding and Screening
20
e-books by eatpl.in · © 2026 · Do not copy or distribute
To sum up. An aircraft picks up static in flight, mainly from precipitation, and if parts end up at different potentials, sparks can jump, which is a fire risk and a source of radio noise. Bonding joins every part with flexible strips fitted to clean bare metal, so the whole aircraft is at the same potential. Bonding also provides the earth return, reduces radio interference and gives lightning a safe path; a poor bond shows up as static on the radios. Static wicks at the trailing edges and tips let the charge leak away by brush discharge, and their purpose is to minimise radio interference. Conductive tyres earth the aircraft at touchdown. For refuelling, bond and earth everything, and bond the nozzle to the tank. Screening absorbs interference using suppressors and metal sheaths, for ignition, commutator machines, slip rings over two hundred rpm and anything switching faster than ten hertz.