Electrics · Chapter 6
DC Generators and Alternators How spinning a coil in a magnetic field makes electricity, how a commutator turns it into DC, the three ways to wind the field, and how regulators, cut-outs and load sharing keep the bus steady.
N S armature turns between the field poles © 2026 eatpl.in. For the personal study of eatpl.in students only. Do not copy or distribute.
e-books by eatpl.in · © 2026 · Do not copy or distribute
Chapter six is about generators and alternators, the machines that turn the engine's mechanical power into the electricity the aircraft runs on. A battery can only store a limited charge, so in flight the generator or alternator is always the primary source of power. We will start with electromagnetic induction and the rules that give the size and direction of the induced voltage, then build a simple generator, see how a commutator turns its alternating output into direct current, and compare series, shunt and compound field windings. Finally we look at alternators, voltage regulators, the reverse current cut-out, and how two generators share the load.
Roadmap
From a spinning loop to a steady bus bar The generator or alternator is the primary source of electrical power in flight; the battery is the back-up.
1 · Induction Relative motion between a conductor and a field induces an EMF . Fleming, Faraday and Lenz.
2 · The DC generator A loop makes AC ; a split-ring commutator turns it into DC. Construction and layout.
3 · Field windings Series , shunt and compound ; self-excitation, flashing the field, armature reaction and ripple.
4 · Control The alternator , voltage regulators, the reverse current cut-out and load sharing .
Chapter 6 · DC Generators and Alternators
2
e-books by eatpl.in · © 2026 · Do not copy or distribute
Here is our route through the chapter. A battery can only give out what was put into it, so in flight the primary source of electrical power is always a generator or an alternator, driven by the engine. In part one we look at electromagnetic induction: how relative motion between a conductor and a magnetic field induces an electromotive force, and the rules of Fleming, Faraday and Lenz. In part two we build a simple generator and see why a loop naturally makes alternating current, and how the split-ring commutator turns it into direct current. Part three is about the field windings, series, shunt and compound, and some practical problems: losing residual magnetism, armature reaction and ripple. Part four covers the alternator, the voltage regulator, the reverse current cut-out, and how two generators share the load on one bus bar.
Part 1 · Induction
Motion plus magnetism makes voltage A conductor cutting lines of flux has an EMF induced in it: electromagnetic induction Only while there is relative motion : stop moving and the EMF stops It does not matter which moves, the conductor or the field Reverse the motion and the EMF reverses Close the circuit and a current flows in proportion to the EMF This turns mechanical energy into electrical energy S N 0 pushed in needle swings right S N 0 held still no EMF, no current S N 0 pulled out needle swings left
Chapter 6 · DC Generators and Alternators
3
e-books by eatpl.in · © 2026 · Do not copy or distribute
Electromagnetic induction is the effect that every generator relies on. When a conductor cuts through lines of magnetic flux, an electromotive force, a voltage, is induced in it. Watch the meter. As the magnet is pushed into the coil, the needle swings one way. Hold the magnet still, inside the coil, and the reading falls back to zero: there is no voltage without relative motion. Now withdraw the magnet and the needle swings the other way, because the motion has reversed. It makes no difference whether the conductor moves through the field or the field moves past the conductor; only the relative motion counts. If the circuit is complete, a current flows in proportion to the induced voltage. So induction converts mechanical energy, the work done moving the magnet, into electrical energy.
Part 1 · Direction
Fleming's right-hand rule for generators Hold thumb, first and second fingers of the right hand at right angles First finger: Field , pointing north to souththuMb: Motion of the conductorseCond finger: Current (conventional, induced)Reverse either the motion or the field and the current reverses Reverse both and the current direction is unchanged thuMb: Motion First finger: Field (N to S) seCond finger: Current (into the page, away from you) N S moved up current into the page
Chapter 6 · DC Generators and Alternators
4
e-books by eatpl.in · © 2026 · Do not copy or distribute
Fleming's right-hand rule gives the direction of the induced current in a generator. Hold your right hand with the thumb, first finger and second finger all at right angles to each other. Point the first finger along the field, from north to south. Point the thumb in the direction the conductor is moving. The second finger then shows the direction of the induced current. A memory aid: first finger, field; thumb, motion, from the M in thumb; second finger, current, from the C in second. In the lower picture, the conductor is moving up through a field running from left to right, and the rule gives a current flowing into the page, away from you. The exam likes this point: reverse either the motion or the field and the current reverses, but reverse both together and the current flows the same way as before. Remember: right hand for generators, left hand for motors.
Part 1 · Size
How big is the induced EMF? Faraday's law Faraday : the induced EMF is proportional to the rate of change of flux Three ways to raise it: cut the flux faster (speed) use a stronger field (flux density) use more turns of wire (a bigger coil) In a generator: speed and turns are fixed in practice, so voltage is controlled through the field strength Faster speed of cutting Stronger field flux density More turns bigger coil Faraday's law EMF = N × (change in flux ÷ time) Example: 200 turns, flux changes by 0.006 Wb in 0.02 s Rate of change = 0.006 ÷ 0.02 = 0.3 Wb/s EMF = 200 × 0.3 = 60 V Same change in 0.01 s (twice as fast): 120 V
Chapter 6 · DC Generators and Alternators
5
e-books by eatpl.in · © 2026 · Do not copy or distribute
Faraday's law tells us how big the induced voltage will be. It says the induced electromotive force is proportional to the rate of change of magnetic flux through the coil. So there are three ways to get more voltage. Cut the flux faster, by moving the conductor more quickly. Use a stronger magnetic field, a greater flux density. Or use more turns of wire, because every turn adds its own share. Let us put numbers on it. A coil of two hundred turns sees its flux change by zero point zero zero six webers in zero point zero two seconds. The rate of change is zero point three webers per second, and two hundred times that is sixty volts. Make the same change twice as fast and you get one hundred and twenty volts. Keep this in mind, because it explains later why generator voltage is controlled through the field current.
Part 1 · Opposition
Lenz's law: the induced current opposes the change Lenz : the induced current flows so that its own magnetic field opposes the change of flux causing itPush a north pole in: the coil's near face becomes a north pole and repels it Pull it out: the near face becomes south and attracts it So you must do work to generate: energy is conserved More load current means a harder-to-turn generator and more engine power In a motor the same effect gives the back EMF (next chapter) S N N near face N repels: opposes approach S N S near face S attracts: opposes removal In a generator: more load current means a stronger opposing force, so the engine must work harder to keep it turning.
Chapter 6 · DC Generators and Alternators
6
e-books by eatpl.in · © 2026 · Do not copy or distribute
Lenz's law tells us which way the induced current flows: always so that its own magnetic field opposes the change that produced it. Push the north pole of a magnet towards a coil, and the induced current makes the near face of the coil a north pole too, which pushes back against the magnet. Pull the magnet away and the near face becomes a south pole, which tries to hold it back. Either way, you have to do work to keep the magnet moving, and that work is where the electrical energy comes from. Nothing is free. In a generator this means that the more current the loads draw, the stronger the opposing force on the armature, and the harder the engine has to drive it. In the next chapter, on motors, the same law gives us the back electromotive force, which limits the current in a spinning motor.
Part 2 · The simple generator
A loop in a field makes alternating current The rotating loop is the armature ; the magnetic field is the field Each end of the loop goes to its own slip ring ; spring-loaded carbon brushes rub on the rings Each side of the loop moves up past one pole, then down past the other So the EMF reverses every half turn : the output is AC A field coil on the poles lets the field strength, and so the voltage, be controlled N S armature loop each end of the loop has its own ring Slip rings: the output reverses every half turn (AC) load
Chapter 6 · DC Generators and Alternators
7
e-books by eatpl.in · © 2026 · Do not copy or distribute
The simplest generator is a single loop of wire turning in a fixed magnetic field. The rotating loop is called the armature, and the magnetic field is called the field. To get the current out, each end of the loop is joined to its own slip ring, and stationary carbon brushes, held against the rings by springs, carry the current to the external circuit, here a lamp. Think about one side of the loop. For half a turn it sweeps up past one pole; for the next half turn it sweeps down past the other. By the right-hand rule, the induced voltage reverses each time, so the current in the lamp flows one way and then the other. This is alternating current, and the lamp brightens and dims twice every revolution. If we wind a field coil around the poles and pass a current through it, we can make the field stronger or weaker, and so control the voltage.
Part 2 · One revolution
Where the voltage peaks and where it is zero 0° 90° 180° 270° 360° +peak −peak 0 zero EMF: neutral plane maximum cutting EMF is maximum when the sides cut the flux at right angles (90° and 270°) and zero when they move along it: the neutral plane (0°, 180°, 360°).
Chapter 6 · DC Generators and Alternators
8
e-books by eatpl.in · © 2026 · Do not copy or distribute
Let us follow the loop through one revolution and plot the voltage. At nought degrees the loop is upright and its two sides are moving sideways, parallel to the lines of flux. They are not cutting any flux at all, so the voltage is zero. This position is called the neutral plane. As the loop turns towards ninety degrees, the sides cut the flux more and more steeply, and at ninety degrees they cut straight across it, so the voltage reaches its positive peak. At one hundred and eighty degrees the sides are moving parallel to the flux again: zero volts, the neutral plane once more. From there to two hundred and seventy degrees each side is moving the opposite way past the poles, so the voltage builds to a negative peak, and it returns to zero at three hundred and sixty. The result is a sine wave: alternating current.
Part 2 · The DC generator
The split-ring commutator makes it DC Replace the slip rings with a split-ring commutator : one ring cut into two segments , insulated from each other Each end of the loop goes to one segment; the commutator turns with the armature Every 180° the segments swap brushes, so the armature connections are reversed The swap happens at the neutral plane , where the EMF is zero The armature still makes AC; the commutator acts as a mechanical rectifier Current always leaves by the same brush N S armature loop two segments, insulated gaps The commutator reverses the connections every half turn load
Chapter 6 · DC Generators and Alternators
9
e-books by eatpl.in · © 2026 · Do not copy or distribute
To get direct current out of our simple generator, we replace the two slip rings with a split-ring commutator. It is a single ring of copper cut into two halves, called segments, with insulation between them. Each end of the armature loop is connected to one segment, and the commutator turns with the armature. Two carbon brushes press on opposite sides. For the first half turn, segment A touches the positive brush; for the next half turn, segment B does. So every hundred and eighty degrees the connections to the armature are reversed, just as the armature voltage itself reverses. The changeover happens at the neutral plane, when the voltage is zero. Inside the armature the current is still alternating; the commutator acts as a mechanical rectifier, so current always leaves the machine by the same brush and flows one way through the load.
Part 2 · Output and ripple
From AC to pulsing DC to smooth DC Slip rings, one loop AC: reverses every half turn 90° 180° 270° 360° 0 Commutator, one loop DC, but pulsing to zero (100% ripple) 90° 180° 270° 360° 0 Commutator, four coils smooth DC: ripple about 8% 90° 180° 270° 360° 0 Commutator ripple : the rise and fall of output, worst at low rpm. More armature coils (and more poles) mean a smoother output.
Chapter 6 · DC Generators and Alternators
10
e-books by eatpl.in · © 2026 · Do not copy or distribute
Here are three outputs side by side. On the left, slip rings on a single loop give a sine wave: alternating current. In the middle, a commutator on the same loop flips the negative half cycles over, so the output is all positive. That is direct current, but it pulses from zero to the peak and back twice every revolution. This rise and fall is called commutator ripple, and it is most noticeable at low revolutions. The cure is to use more coils. On the right, four coils are spaced around the armature, each with its own pair of commutator segments, and the brushes always pick the coil that is near its peak. The output now only dips to about ninety-two per cent of the peak, a ripple of about eight per cent. Real generators use many coils, and more poles too, so the output is very nearly steady.
Part 2 · A practical machine
Inside a real DC generator Yoke : the steel frame; it carries the magnetic circuit between the polesPole pieces wound with field coils : an electromagnet whose strength can be controlledArmature : a laminated iron drum with many coils in slots, turning with a small air gap Commutator : many copper segments, one pair per coilCarbon brushes , spring-loaded, carry the full load currentDriven from the engine by a belt or the accessory gearbox N S Field coil Yoke (frame) Pole piece Armature conductors in slots Shaft (engine drive) Commutator and brushes sit at one end of the shaft
Chapter 6 · DC Generators and Alternators
11
e-books by eatpl.in · © 2026 · Do not copy or distribute
A practical generator improves on the single loop in several ways. The steel yoke, or frame, holds everything together and completes the magnetic circuit between the poles. The pole pieces are wound with field coils, so the field is an electromagnet whose strength we can control. The armature is a drum of thin iron laminations, which reduces eddy-current losses, carrying many coils of copper in slots around its edge. The gap between the armature and the pole faces is kept as small as possible so that the flux is strong. Each coil has its own pair of copper segments on the commutator, and spring-loaded carbon brushes rub on them. Notice that in a DC generator the brushes and commutator must carry the full output current of the machine. Remember that point when we compare it with the alternator. The generator is driven by the engine through a belt or the accessory gearbox.
Part 2 · In the aircraft
Generator, battery and loads in parallel Generator, battery and loads are all connected in parallel to the bus bar , a distribution point The generator is set slightly above battery voltage so it supplies the loads and charges the battery 14 V system with a 12 V battery; 28 V system with a 24 V batteryMost light aircraft use a single wire with airframe earth return If the generator fails, the battery carries the loads, but only for a limited time BUS BAR G 28 V + 24 V loads earth return (airframe) charging All in parallel: generator voltage kept just above battery
Chapter 6 · DC Generators and Alternators
12
e-books by eatpl.in · © 2026 · Do not copy or distribute
In the aircraft, the generator, the battery and all the loads are connected in parallel to a bus bar, which is simply a distribution point, a solid strip that everything takes its supply from. Because they are in parallel, they all sit at the same voltage. The generator output is set slightly higher than the battery's own voltage, so the generator not only supplies the loads but also pushes a charging current into the battery. So an aircraft with a twelve volt battery has a fourteen volt system, and one with a twenty-four volt battery has a twenty-eight volt system. The exam often asks this: a twenty-four volt aircraft has twenty-eight volt generators. Most light aircraft use a single wire to each load, and the current returns through the metal airframe. If the generator fails, the battery takes over all the loads, but only until it goes flat.
Part 3 · Field windings
The series-wound generator Field winding in series with the armature and the load: the load current is the field current So the field has few turns of thick wire More load → stronger field → more voltage Until the pole pieces saturate : then no further rise Voltage changes with load, so it is not used for aircraft supplies A armature series field load full load load current terminal voltage rises until the iron saturates
Chapter 6 · DC Generators and Alternators
13
e-books by eatpl.in · © 2026 · Do not copy or distribute
How we connect the field winding changes how the generator behaves. In a series-wound generator, the armature, the field winding and the external load are all in series, so the same current flows through all three. The load current is the field current. Because that current is large, only a few turns of thick wire are needed to make a strong field. Now look at the curve. With no load, there is no field current, and the output is tiny. As the loads draw more current, the field gets stronger and the voltage rises. That carries on until the iron of the pole pieces saturates, when it can take no more flux, and the voltage stops rising, then begins to fall. A supply whose voltage swings up and down with the load is useless for aircraft equipment, which needs a constant voltage. So the series-wound generator is not used.
Part 3 · Field windings
The shunt-wound generator Field winding in parallel (shunt) with the armature Field current set by terminal voltage ÷ field resistance : many turns of fine wire , small current Builds up voltage quickly, because field current flows even with no load Terminal voltage falls only slightly from no load to full load A variable resistance in series with the field sets the voltage Used where a near-constant voltage is needed A armature load shunt field voltage control full load load current terminal voltage small droop with load
Chapter 6 · DC Generators and Alternators
14
e-books by eatpl.in · © 2026 · Do not copy or distribute
In a shunt-wound generator, the field winding is connected in parallel with the armature, straight across its output. The field current therefore depends on the terminal voltage and the resistance of the field winding, not on the load. The winding has many turns of fine wire and needs only a small current to make the flux it needs. Because field current flows even when the external circuit is open, the voltage builds up quickly when the generator starts. The curve shows the key property: from no load to full load, the terminal voltage falls only a little, mainly because of the voltage drop across the armature's own resistance. So the shunt generator is the one to use where a fairly constant voltage is needed. And its voltage is easy to control: put a variable resistance in series with the shunt field. That is exactly what a voltage regulator does.
Part 3 · Field windings
The compound-wound generator Both windings: a shunt field across the armature and a series field in the load lineOne shunt coil and one series coil share each pole piece As load rises, the series field strengthens the total flux This makes up for the drop across the armature resistance Result: an almost constant output voltage from no load to full load A armature series field load shunt field voltage control full load load current terminal voltage almost flat
Chapter 6 · DC Generators and Alternators
15
e-books by eatpl.in · © 2026 · Do not copy or distribute
The compound-wound generator combines the two. It has a shunt field across the armature and a series field carrying the load current, and one coil of each is wound on every pole piece, sometimes inside a single covering. Why bother? Remember that a shunt generator's voltage droops a little as the load increases, because the load current flowing through the armature's resistance drops some voltage inside the machine. In the compound machine, that same load current also flows through the series field, which strengthens the total magnetic field just enough to induce extra voltage and make up for the drop. With the right balance the output voltage stays almost constant from no load to full load. This is the idea behind the starter-generator you will meet in the next chapter, which is a compound machine.
Part 3 · Side by side
Series, shunt and compound generators Type Field connection Field winding Voltage as load rises Use Series In series with armature and load Few turns, thick wire; carries load current Rises until saturation, then fallsNot for aircraft supplies Shunt In parallel with the armature Many turns, fine wire; small current Falls gradually (small droop)Near-constant voltage; easy to regulate Compound Shunt across armature + series in load line Both, on each pole Almost constant Constant-voltage loads; starter-generators
Exam phrase: the output of a shunt-wound generator falls gradually as load is applied . Voltage is controlled by a variable resistance in series with the shunt field .
Chapter 6 · DC Generators and Alternators
16
e-books by eatpl.in · © 2026 · Do not copy or distribute
Let us put the three windings side by side. The series generator has its field in series with the armature and the load, a few turns of thick wire carrying the whole load current, and its voltage rises with load until the iron saturates. It is not suitable for aircraft supplies. The shunt generator has its field in parallel with the armature, many turns of fine wire carrying a small current, and its voltage falls gradually as the load increases. That gentle droop is a favourite exam answer. Its voltage is easily controlled by a variable resistance in series with the field. The compound generator has both windings on each pole, and the series winding cancels out the droop, giving an almost constant voltage. Practical aircraft generators are shunt or compound machines, with a voltage regulator controlling the shunt field current.
Part 3 · Getting started
Self-excitation and flashing the field Residual magnetism stays in the pole pieces when the generator stopsOn start-up it gives a small voltage, which feeds the field and builds up : the generator is self-excited (internally excited) An externally excited generator needs the battery to start its field Residual magnetism is lost through time, heat, shock, an AC field or reversed polarity Cure: flash the field , a brief current through the field in the normal direction Some aircraft have a cockpit switch for it time after start output voltage regulated voltage residual self-excitation: voltage feeds field no residual magnetism: stays at zero Residual magnetism can be lost through: time, heat, shock or hammering, an AC field, reversed polarity Cure: flash the field (battery, normal direction)
Chapter 6 · DC Generators and Alternators
17
e-books by eatpl.in · © 2026 · Do not copy or distribute
How does a shunt generator get started, when its field needs current from its own output? The answer is residual magnetism. When the generator stops, a little magnetism remains in the iron pole pieces. As soon as the armature turns, it cuts this weak flux and produces a small voltage. That voltage drives a little current through the field winding, which strengthens the field, which raises the voltage further, and the output builds up rapidly until the regulator holds it at its set value. A generator that starts itself this way is called self-excited, or internally excited. One with no residual magnetism must be externally excited, with the battery supplying the field to begin with. Residual magnetism can be lost over time, through heat, shock or hammering, an alternating field, or a reversed polarity. Then the generator will not build up at all. The cure is flashing the field: a brief current through the field winding in its normal direction.
Part 3 · A problem under load
Armature reaction and interpoles Load current in the armature makes its own magnetic field This distorts the main field and shifts the neutral plane In a generator it moves in the direction of rotation , more with more current Brushes no longer at the neutral plane: arcing at the commutator and loss of power Cure: interpoles , small poles between the main poles, wound in series with the load Their field opposes the armature field and pulls the neutral plane back N S No load N S On load neutral plane moved with the rotation neutral plane vertical Brushes off the neutral plane: arcing, power loss Cure: interpoles between the main poles, wound in series with the load, so the correction always grows with the current
Chapter 6 · DC Generators and Alternators
18
e-books by eatpl.in · © 2026 · Do not copy or distribute
There is a snag when a generator is loaded. The load current flowing in the armature coils makes a magnetic field of its own, and it interacts with the main field from the poles, twisting it out of shape. This distortion is called armature reaction. Its effect is to shift the neutral plane, the position where the coils cut no flux, and in a generator the neutral plane moves forward, in the direction of rotation. The bigger the load current, the further it moves. Now the brushes are no longer switching coils at the moment their voltage is zero, so there is sparking and arcing at the commutator, wear, and a loss of power. The best cure is interpoles: small extra poles between the main poles, wound in series with the load, so their strength always matches the armature current. Their field opposes the armature's field and bends the neutral plane back where it belongs.
Part 4 · The DC alternator
Turn the machine inside out: the alternator Rotating field , fed through slip rings with a small field currentStationary armature (three-phase windings) delivers the large load current directlyAC is turned into DC by a diode rectifier in the end frame, not a commutator No commutator arcing, a better power-to-weight ratio , and full output at low rpm The diodes also block reverse current from the battery Needs battery power to excite its field: most light aircraft use alternators N S stationary armature (3-phase) rotating field, via slip rings 6-diode rectifier AC DC out Big current from fixed windings: no commutator arcing
Chapter 6 · DC Generators and Alternators
19
e-books by eatpl.in · © 2026 · Do not copy or distribute
The alternator turns the generator inside out. The field is now the rotating part: an electromagnet on the shaft, fed with a small field current through two slip rings and brushes. The armature, the windings in which the output is induced, is stationary, built into the frame around the rotor, usually as three sets of windings giving three-phase alternating current. Because the armature does not move, the large output current is taken straight from fixed terminals, with no commutator and no sliding contacts. Only the small field current passes through the slip rings, so there is no arcing or sparking. The alternating output is changed to direct current by a bridge of diodes in the end frame. The alternator is lighter for its output, gives full output even at low engine speed, and its diodes block reverse current from the battery. But it needs battery power to excite its field, so most light aircraft now use alternators.
Part 4 · Comparison
DC generator or DC alternator? DC generator DC alternator Armature Rotating Stationary Field Stationary Rotating , via slip ringsAC to DC by Commutator Diode rectifier Sliding contacts carry The full load current : arcing and sparking Only the small field current Output at low rpm Poor; full output near half engine speed Full output even at low rpmReverse current protection Needs a reverse current cut-out Provided by the diodes Starting the field Residual magnetism (self-excited) Needs battery excitation
The alternator wins on power-to-weight , low-rpm output and maintenance ; that is why most modern light aircraft use one.
Chapter 6 · DC Generators and Alternators
20
e-books by eatpl.in · © 2026 · Do not copy or distribute
This table sums up the comparison, and it is very examinable. The DC generator has a rotating armature and a stationary field, and converts its alternating armature voltage to direct current with a commutator. Because the whole load current has to pass through the commutator and brushes, it suffers from arcing and sparking. The alternator has a stationary armature and a rotating field, uses diodes to rectify, and only the small field current passes through its slip rings. A generator gives its full output only when the engine is turning fairly fast, at about half engine speed or more, whereas an alternator gives full output even at low speeds, for example while taxiing. A generator needs a reverse current cut-out to stop the battery motoring it; in an alternator, the diodes do that job. One disadvantage: the alternator needs battery power to excite its field, so it cannot start with a completely flat battery.
Part 4 · Voltage control
Why we control the field current Output depends on speed , field strength , number of turns and the size and shape of the turns Turns, size and shape are fixed by design ; speed is tied to the engine So the only practical control is the field current The voltage regulator : a variable resistance in series with the field , and a sensing coil across the output It keeps voltage constant whatever the rpm and load; the current varies with demand The generator switch works in the field circuit: off means no field, no output Field current Field strength Output voltage Regulator senses adjusts Disturbances engine rpm electrical load Speed: tied to the engine. Turns, size, shape: design. Only field current is free to adjust. 14 V system (12 V battery) · 28 V system (24 V battery)
Chapter 6 · DC Generators and Alternators
21
e-books by eatpl.in · © 2026 · Do not copy or distribute
The output voltage of a generator or alternator depends on four things: how fast it turns, how strong the field is, how many turns the armature has, and their size and shape. The number, size and shape of the turns are fixed when the machine is designed. The speed is tied to the engine. So the only practical control is the strength of the field, which we adjust by changing the current in the field winding. That is the job of the voltage regulator. It has two essential parts: a variable resistance in series with the field winding, and a sensing or control coil connected across the output, which measures the voltage, sometimes called the electrical pressure. The regulator keeps the voltage constant whatever the engine speed and load, while the current varies with demand. The generator master switch also works in the field circuit: switch it off and there is no field, so no output.
Part 4 · Regulators
The carbon pile regulator A stack of carbon discs in series with the field: squeeze it and its resistance falls A spring compresses the pile; a control coil across the output pulls against the spring Voltage rises : coil pulls harder, pile loosens , resistance rises , field current falls, voltage falls back Voltage falls : the spring squeezes the pile, field current rises Modern regulators do the same job with transistors carbon pile iron plate spring control coil pull G + generator field winding V up → coil pulls harder → pile looser → R up → field current down → V back down
Chapter 6 · DC Generators and Alternators
22
e-books by eatpl.in · © 2026 · Do not copy or distribute
The carbon pile regulator is the classic way of making a variable resistance. A pile of carbon discs is connected in series with the generator's field winding. When the discs are squeezed tightly together, they touch over more area and the resistance is low; when the pressure is released, the resistance rises. A spring squeezes the pile. Against the spring pulls an electromagnet, the control coil, connected across the generator output, so its pull depends on the output voltage. Now suppose the voltage rises. The coil pulls harder, drawing the iron plate away and loosening the pile. Its resistance goes up, the field current falls, the field weakens, and the voltage comes back down to its set value. If the voltage falls, the spring wins, squeezes the pile, and the field current rises. Modern regulators do exactly the same job electronically, with transistors and diodes.
Part 4 · Regulators
The vibrating contact regulator Spring-closed contacts in the field circuit , with a fixed resistor across them Voltage reaches its set value: the coil opens the contacts; field current must pass through the resistor and falls Voltage drops: the spring closes the contacts again It switches 50 to 200 times a second , depending on load The average field current holds the voltage steady A current limiter works the same way to stop overload fixed resistor contacts (spring closed) to field time (40 ms shown) 28 V set point 26 V 28 V 30 V 4 openings in 40 ms ≈ 100 per second
Chapter 6 · DC Generators and Alternators
23
e-books by eatpl.in · © 2026 · Do not copy or distribute
The vibrating contact regulator gets the same result in a different way. Instead of varying a resistance smoothly, it switches a fixed resistance in and out very quickly. A pair of spring-loaded contacts sits in the field circuit, with a resistor connected across them. When the generator starts, the contacts are closed and the field gets its full current, so the voltage builds up. When the voltage reaches its regulated value, the regulator coil becomes strong enough to pull the contacts open. Now the field current has to pass through the resistor, so it falls, and the voltage begins to drop. The coil weakens, the spring closes the contacts, and the cycle repeats. Depending on the load, this happens about fifty to two hundred times a second, so the voltage simply ripples in a narrow band around its set point, as the graph shows. A current limiter uses the same trick to protect against overload.
Part 4 · Protection
The reverse current cut-out Stops the battery driving current back into a generator whose voltage has fallen below it Voltage coil : many fine turns, across the output. Current coil : a few thick turns, in the lineCloses when generator voltage rises above battery voltageCurrent through the current coil helps hold it closed Opens on reverse current : the current coil now opposes the voltage coilNot needed with an alternator : its diodes block reverse current G current coil (few thick turns) contacts voltage coil (many fine turns) + battery Closed by rising generator voltage (above battery) Opened by reverse current from the battery Not needed with an alternator: diodes block it
Chapter 6 · DC Generators and Alternators
24
e-books by eatpl.in · © 2026 · Do not copy or distribute
When the engine is stopped or running slowly, the generator voltage is below the battery voltage. If they were simply connected, current would flow backwards from the battery into the generator, trying to drive it as a motor, flattening the battery and possibly damaging the machine. The reverse current cut-out prevents this. It is a relay with two coils on one core. The voltage coil, many turns of fine wire, is connected across the generator output. When the generator voltage climbs above battery voltage, this coil closes the contacts and puts the generator on line. The current coil, a few turns of thick wire in the main line, then carries the output current, and its magnetism helps to hold the contacts shut. If the generator voltage falls below the battery's, current reverses through the current coil. Its field now opposes the voltage coil, and the spring opens the contacts. So: closed by rising voltage, opened by reverse current.
Part 4 · Two generators
Paralleling and load sharing BUS BAR · aircraft loads G GEN 1 line contactor voltage regulator control coil equalising coil G GEN 2 line contactor voltage regulator control coil equalising coil equalising relay contacts equalising current: high gen → low gen The equalising current lowers the high generator and raises the low one until they match Each generator should carry half the load . That needs identical voltages ; the equalising coils trim each field until they match.
Chapter 6 · DC Generators and Alternators
25
e-books by eatpl.in · © 2026 · Do not copy or distribute
With two engines, two generators feed one bus bar in parallel, each through its own line contactor. This doubles the capacity and keeps power on if one fails. For the load to be shared equally, the two output voltages must be exactly the same. If one generator is even slightly higher, current flows from it towards the lower one, a recirculating current. The higher generator then carries most of the load, the lower one carries little or none, and in the worst case current flows into the low generator and tries to drive it as a motor, against the engine. The load sharing circuit prevents this. Each voltage regulator has an extra equalising coil, and the equalising coils are connected together through equalising relay contacts, which close with each line contactor once both generators are on line. Any difference in voltage drives a current through them, which lowers the field of the high generator and raises the field of the low one, until their voltages, and their loads, are equal.
Part 4 · Worked example
How a small voltage difference upsets the sharing Two generators on one bus, each with an internal resistance of 0.005 Ω , sharing a 200 A load:
Gen 1 EMF Gen 2 EMF Bus voltage Gen 1 current Gen 2 current Result 28.5 V 28.5 V 28.0 V 100 A 100 A Equal sharing 28.6 V 28.4 V 28.0 V 120 A 80 A Gen 1 takes more 28.8 V 28.2 V 28.0 V 160 A 40 A Badly unbalanced 29.0 V 28.0 V 28.0 V 200 A 0 A Gen 2 carries nothing 29.2 V 27.8 V 28.0 V 240 A −40 A Reverse current : Gen 2 motoring
Each 0.1 V of difference shifts 20 A from one machine to the other. The reverse current relay trips a generator that starts motoring; the equalising circuit stops it getting that far.
Chapter 6 · DC Generators and Alternators
26
e-books by eatpl.in · © 2026 · Do not copy or distribute
Let us put numbers on this. Two generators share a two hundred amp load, and each has an internal resistance of zero point zero zero five ohms. With both at twenty-eight point five volts, the bus sits at twenty-eight volts and each machine supplies one hundred amps. Now raise one and lower the other by just a tenth of a volt each. The bus voltage does not change, but generator one now gives one hundred and twenty amps and generator two only eighty. A three tenths of a volt split gives one hundred and sixty against forty. At half a volt each way, generator two is carrying nothing at all. Go a little further and its current becomes negative: forty amps flowing into it, so it is motoring and its reverse current relay should trip it off line. The lesson is that the voltages must match within a small fraction of a volt, which is why the equalising circuit is needed.
Summary
Generators and alternators: the essentials Induction Relative motion induces EMF. Right hand : thuMb Motion, First Field, seCond Current. EMF ∝ rate of change of flux . Lenz: it opposes the change.
Commutator A loop makes AC . The split ring reverses the connections every 180° at the neutral plane: DC out. More coils, less ripple .
Windings Series : rises with load, not used. Shunt : falls gradually. Compound : almost constant. Flash the field if residual magnetism is lost.
Armature reaction Load current shifts the neutral plane with rotation : arcing. Interpoles in series with the load correct it.
Alternator Rotating field , stationary armature , diode rectifier. Better power-to-weight, full output at low rpm, no cut-out needed.
Regulator Varies field current through a resistance in series with the field , sensing output voltage. 14 V for 12 V, 28 V for 24 V .
Cut-out Closed by rising generator voltage , opened by reverse current . Stops the battery motoring the generator.
Load sharing Paralleled voltages must be equal . Equalising coils trim the fields; otherwise a recirculating current flows.
Chapter 6 · DC Generators and Alternators
27
e-books by eatpl.in · © 2026 · Do not copy or distribute
Let us pull the chapter together. Relative motion between a conductor and a field induces a voltage; the right-hand rule gives its direction, Faraday's law says its size depends on the rate of change of flux, and Lenz's law says the induced current opposes the change. A loop naturally generates alternating current, and the split-ring commutator reverses its connections every half turn to give direct current; more coils mean less ripple. Series generators are not used; shunt generators droop gently; compound generators hold an almost constant voltage. Armature reaction shifts the neutral plane, and interpoles correct it. The alternator has a rotating field, a stationary armature and diodes, and beats the generator on weight and low-speed output. The regulator controls the field current. The cut-out closes on rising voltage and opens on reverse current. And paralleled generators must have equal voltages to share the load.