Electrics · Chapter 7
DC Motors and Actuators How a current in a magnetic field makes a turning force, why back EMF limits the current, how series and shunt motors behave, and how electric actuators move valves, flaps and trim.
N S electrical power in, turning force out © 2026 eatpl.in. For the personal study of eatpl.in students only. Do not copy or distribute.
e-books by eatpl.in · © 2026 · Do not copy or distribute
Chapter seven is about DC motors and the electrical actuators built from them. A motor is a generator working backwards: put current into it and it gives out a turning force. On an aircraft, motors start engines, drive pumps and fans, and inside actuators they open fuel valves, move flaps and trim tabs, and even retract landing gear. We will see where the force comes from, why a spinning motor generates a back EMF that limits its own current, and how series and shunt motors differ. Then we look at the starter-generator, and at solenoid, rotary and linear actuators with their limit switches, brakes, clutches and position indicators.
Roadmap
From a pushed wire to a moving flap A motor converts electrical energy into mechanical energy : the reverse of a generator, using the same parts.
1 · The motor effect Force on a conductor, the left-hand rule , the commutator and the practical motor.
2 · Back EMF Why a turning motor limits its own current, and the slow start resistor .
3 · Motor types Series and shunt motors, reversing, and the starter-generator .
4 · Actuators Solenoid , rotary and linear actuators: limit switches, brakes, clutches and indicators.
Chapter 7 · DC Motors and Actuators
2
e-books by eatpl.in · © 2026 · Do not copy or distribute
Here is the plan for this chapter. An electric motor converts electrical energy into mechanical energy, the exact reverse of a generator, and it is built from the same parts: field poles, an armature, a commutator and brushes. In fact many DC machines can work as either. In part one we see where the force comes from, how to find its direction with the left-hand rule, and how the commutator keeps a motor turning one way. Part two is about back electromotive force, the voltage a spinning motor generates against its own supply, and why motors need protecting from a huge starting current. Part three compares series and shunt motors, shows how a motor is reversed, and introduces the starter-generator. Part four covers the actuators that do the remote work on an aircraft: solenoid, rotary and linear, with their limit switches, brakes, clutches and position indicators.
Part 1 · The motor effect
A current in a magnetic field feels a force A current-carrying conductor in a magnetic field experiences a force The force is at right angles to both the field and the current Its size: F = B × I × L (flux density × current × length in the field) The conductor's own field adds to the main field on one side and cancels on the other: it is pushed towards the weaker side No current, or no field: no force N S force strong field weak field current out of the page F = B × I × L B = 0.8 T, I = 50 A, L = 0.25 m F = 0.8 × 50 × 0.25 = 10 N Two sides at 5 cm radius: torque = 2 × 10 × 0.05 = 1 N·m
Chapter 7 · DC Motors and Actuators
3
e-books by eatpl.in · © 2026 · Do not copy or distribute
The motor effect is simple to state: a conductor carrying a current in a magnetic field experiences a force. Here the field runs from the north pole above to the south pole below. With no current, nothing happens. Now pass a current through the conductor, towards you. The conductor makes its own circular magnetic field, which adds to the main field on one side and cancels it on the other, and the conductor is pushed sideways, out of the stronger field towards the weaker. The force is always at right angles to both the field and the current. Its size is the flux density times the current times the length of conductor in the field. For example, zero point eight tesla, fifty amps and twenty-five centimetres give ten newtons. Two such sides on a loop of five centimetres radius give a torque of one newton metre.
Part 1 · Direction
Fleming's left-hand rule for motors Left hand , thumb and first two fingers at right anglesFirst finger: Field (north to south)seCond finger: Current (conventional)thuMb: Motion , the direction of the forceReverse either current or field: the motor reverses ; reverse both : unchanged Left hand for motors , right hand for generators thuMb: Motion (force) First finger: Field (N to S) seCond finger: Current (out of the page, towards you) LEFT hand: motors · RIGHT hand: generators Reverse current OR field: reverses. Reverse both: unchanged.
Chapter 7 · DC Motors and Actuators
4
e-books by eatpl.in · © 2026 · Do not copy or distribute
To find the direction of the force, use Fleming's left-hand rule. Hold your left hand with the thumb and first two fingers at right angles. Point the first finger along the field, from north to south. Point the second finger along the current, conventional current, from positive to negative. The thumb then shows the direction of motion, the way the conductor is pushed. It is the same finger code as before: first finger field, second finger current, thumb motion. The only difference is the hand: left for motors, right for generators. One way to remember it: in Britain we drive on the left, so motors use the left hand. The consequences are exam favourites. Reverse either the current or the field and the motor turns the other way. Reverse both together and it keeps turning in the same direction.
Part 1 · The simple motor
The commutator keeps the torque one way A loop between the poles, fed from a DC supply through brushes and a split-ring commutator The two sides carry current in opposite directions , so one is pushed up and the other down: a turning couple Without a commutator the loop would rock to the vertical and stop The commutator reverses the loop current every half turn , so the torque always acts the same way Here it acts as a reversing switch ; in a generator, as a rectifier N S force up force down + DC Commutator reverses the loop current every half turn so the torque always acts the same way
Chapter 7 · DC Motors and Actuators
5
e-books by eatpl.in · © 2026 · Do not copy or distribute
Now bend the conductor into a loop and place it between the poles. A DC supply feeds current into the loop through two brushes and a split-ring commutator. Current flows along one side of the loop and back along the other, so the two sides carry current in opposite directions. By the left-hand rule, one side is pushed up and the other down. That pair of forces is a turning couple, and the loop rotates. But think what would happen with plain slip rings. After half a turn the sides would have swapped places, the forces would now oppose the rotation, and the loop would just rock to the upright position and stop there. The commutator solves this by reversing the current in the loop every half turn, exactly as each side moves past from one pole to the other. So the torque always acts the same way. In a motor the commutator is a reversing switch; in a generator it is a rectifier.
Part 1 · A practical motor
One machine, two jobs A single loop is weak and jerky; real motors use many armature coils on a laminated iron core , with matching commutator segments The field comes from electromagnets (field windings), with the smallest possible air gap Field windings let the speed be controlled through field strength Motors and generators share the same parts : many DC machines can work as either Generator: mechanical in, electrical out. Motor: electrical in, mechanical out Generator mechanical in electrical out right-hand rule Motor electrical in mechanical out left-hand rule
Chapter 7 · DC Motors and Actuators
6
e-books by eatpl.in · © 2026 · Do not copy or distribute
A single loop could never turn a heavy load, and its torque would pulse twice a revolution. So, just as with the generator, a practical motor has many coils wound on a laminated iron armature core, with a matching number of commutator segments. The field is produced by electromagnets, the field windings on the pole pieces, and the gap between the armature and the poles is kept as small as possible to keep the flux strong. Using field windings rather than permanent magnets also means the motor's speed can be controlled by adjusting the field. Look closely and a DC motor and a DC generator have exactly the same parts: yoke, poles, field windings, armature, commutator and brushes. In fact many DC machines can be used as either. Drive it with an engine and it is a generator, giving out electrical power. Feed it with electrical power and it is a motor, giving out mechanical power.
Part 1 · Exam check
Generator, motor, and changing AC and DC Generator Motor Energy Mechanical → electrical Electrical → mechanical Hand rule Right handLeft handCommutator acts as A mechanical rectifier : armature AC → DC output A reversing switch : keeps torque one way Induced EMF The output voltage The back EMF , opposing the supply
Changing AC to DC : a commutator (inside a DC generator) or a rectifier (diodes). Changing DC to AC : an inverter , static or rotary.
Chapter 7 · DC Motors and Actuators
7
e-books by eatpl.in · © 2026 · Do not copy or distribute
This comparison table is worth learning, because questions like to mix the two machines up. A generator turns mechanical energy into electrical, and its direction rule is the right hand; a motor turns electrical energy into mechanical, and uses the left hand. In both, the commutator is doing the same mechanical job, swapping the connections every half turn, but we describe it differently. In a generator it is a mechanical rectifier, turning the alternating voltage in the armature into a direct current output. In a motor it is a reversing switch, keeping the torque in one direction. Both machines also have an induced voltage: in a generator it is the output, in a motor it is the back EMF. And a common exam question: what changes AC into DC? In a DC generator, the commutator; as a separate device, a rectifier. Going the other way, from DC to AC, needs an inverter.
Part 2 · Back EMF
A spinning motor is also a generator The turning armature cuts flux, so an EMF is induced in it By Lenz's law it opposes the supply : the back EMF Back EMF is proportional to speed , and always a little less than the supply Armature current = (supply − back EMF) ÷ armature resistance At standstill there is no back EMF : the starting current is very large Load the motor, it slows, back EMF falls, current and torque rise motor speed → supply 28 V back EMF 140 A at standstill armature current I = (V − back EMF) ÷ R back EMF ∝ speed, always a little less than V
Chapter 7 · DC Motors and Actuators
8
e-books by eatpl.in · © 2026 · Do not copy or distribute
Once a motor's armature starts turning, its conductors are moving through the field, so a voltage is induced in them, exactly as in a generator. By Lenz's law, this induced voltage opposes the thing causing it, so it pushes back against the supply. We call it the back electromotive force. Back EMF is proportional to speed, and it can never quite reach the supply voltage, because there must always be some difference left over to drive the current that keeps the motor turning. The armature current is the supply voltage minus the back EMF, divided by the armature resistance. The graph shows the consequence. At standstill there is no back EMF at all, so the current is huge: twenty-eight volts across zero point two ohms is one hundred and forty amps. As the motor speeds up, the back EMF climbs and the current falls away. And if the load increases, the motor slows, the back EMF falls, and more current flows to give more torque.
Part 2 · Worked example
Back EMF in numbers: 28 V supply, 0.2 Ω armature Condition Back EMF Supply − back EMF Armature current Power input Standstill (starting) 0 V 28 V 140 A 3920 W Heavy load, slow 20 V 8 V 40 A 1120 W Normal load 26 V 2 V 10 A 280 W Light load, fast 27 V 1 V 5 A 140 W
The motor adjusts itself: more load → slower → less back EMF → more current → more torque . The starting current is the danger.
Chapter 7 · DC Motors and Actuators
9
e-books by eatpl.in · © 2026 · Do not copy or distribute
Let us put numbers on back EMF. Our motor runs from twenty-eight volts and its armature resistance is zero point two ohms. At standstill there is no back EMF, so the whole twenty-eight volts drives current through zero point two ohms: one hundred and forty amps, nearly four kilowatts, enough to overheat the windings, burn the brushes and pull down the bus voltage. With a heavy load the motor runs slowly, perhaps generating twenty volts of back EMF. Now only eight volts is left to drive the current, and the current is forty amps. At normal load, with twenty-six volts of back EMF, the current is ten amps, and on light load with twenty-seven volts back EMF, just five amps. Notice how the motor regulates itself: give it more work, it slows a little, the back EMF drops, and it automatically draws more current to make more torque. The real danger is the moment of starting.
Part 2 · Protection
The slow start resistor At start there is no back EMF , so only the armature resistance limits current A slow start resistor is switched in series with the armature for starting Once the motor is turning and back EMF has built up, a centrifugal switch or time switch bypasses it Full current is then applied to the armature Example: adding 0.8 Ω cuts the starting current from 140 A to 28 A + start slow start resistor bypass switch (centrifugal or timer) M no resistor 140 A with 0.8 Ω resistor 28 A Starting: 28 V ÷ 0.2 Ω = 140 A; 28 V ÷ (0.2 + 0.8) Ω = 28 A
Chapter 7 · DC Motors and Actuators
10
e-books by eatpl.in · © 2026 · Do not copy or distribute
Because there is no back EMF at the moment of starting, the only thing limiting the current is the small resistance of the armature. To protect the motor and the supply, some motors have a slow start resistor. It is switched in series with the armature when the motor is first started, so it limits the current until the armature is turning and a back EMF has been established. Then a centrifugal switch, worked by the speed of the motor, or a time switch, bypasses the resistor and full current is applied to the armature. With our numbers, adding a resistor of zero point eight ohms makes the total resistance one ohm, so the starting current falls from one hundred and forty amps to twenty-eight amps, a fifth of the value. The motor starts more gently, and when the resistor is shorted out it has already built up enough back EMF to keep the current within limits.
Part 3 · Motor types
The series-wound motor Field in series with the armature: few turns of thick wire ; field strength follows armature current Very high starting torque : torque rises roughly with current squaredSpeed varies with load : slow on heavy load, very fast on light load Off load it can overspeed and disintegrate : never start or run it off load Not for constant speed or intermittent loads Uses: starter motors , actuators , landing gear + series field M armature speed: runaway as load → 0 torque ∝ I² full load load current
Chapter 7 · DC Motors and Actuators
11
e-books by eatpl.in · © 2026 · Do not copy or distribute
In a series-wound motor the field winding is in series with the armature, so the whole armature current flows through it. The field is a few turns of thick wire, and its strength rises and falls with the current. If the load increases, the motor slows, the back EMF falls, and more current flows through both armature and field. More current and a stronger field together give a big rise in torque, roughly with the square of the current. That is why the series motor has a very high starting torque, ideal for engine starters, landing gear and actuators. The danger is at light load. With little load, the current is small and the field is weak, so the motor has to spin very fast to build up enough back EMF. Remove the load completely and it can overspeed until it disintegrates. So a series motor must never be started or run off load, and it is not used where constant speed is needed or the load comes and goes.
Part 3 · Motor types
The shunt-wound motor Field connected directly across the supply : many turns of fine wire Field strength is constant , independent of load and armature current Torque varies directly with armature current Speed falls only about 10% from no load to full load: a constant speed motor Safe to start on light or no load Uses: fans , centrifugal pumps , motor-generator units + shunt field M armature speed: about 10% drop to full load torque ∝ I full load load current
Chapter 7 · DC Motors and Actuators
12
e-books by eatpl.in · © 2026 · Do not copy or distribute
In a shunt-wound motor, the field winding is connected directly across the supply, in parallel with the armature. It is many turns of fine wire carrying a small current, and because the supply voltage is steady, the field strength is constant whatever the load. Torque then depends directly on the armature current. Watch what happens when the load changes. Add load and the motor slows slightly, the back EMF falls, more armature current flows, and the extra torque meets the load. Remove load and the motor speeds up slightly, the back EMF rises, the current and torque fall, and the speed settles again. From no load to full load the speed changes by only about ten per cent of the no-load speed, so the shunt motor is treated as a constant speed motor. It can safely start light or with no load at all, so it is used for fans, centrifugal pumps and motor-generator units.
Part 3 · Side by side
Speed against torque: series and shunt motors torque (× full-load torque) speed (× full-load speed) 0.5 1.0 1.5 2.0 2.5 1 2 3 full load series: speed soars as load falls shunt: nearly constant speed Series · huge starting torque · speed varies with load · never run off load · starters, actuators, gear Shunt · steady speed (±10%) · moderate starting torque · can start light · fans, pumps, motor-generators Both run at rated speed at full-load torque; off load, the series motor races away while the shunt motor barely speeds up.
Chapter 7 · DC Motors and Actuators
13
e-books by eatpl.in · © 2026 · Do not copy or distribute
Here are the two motors on one graph of speed against torque, both scaled so they run at their rated speed at full-load torque. The blue shunt line is almost flat: as the torque demanded rises, the speed falls only a little. That is the constant speed motor. The orange series curve is completely different. At high torque it runs slowly, and it can deliver far more torque than the shunt motor at low speed, which is why it is chosen for starting engines and driving heavy actuators. But follow the curve towards the left, as the load is taken off: the speed shoots up, and with no load at all it would keep on accelerating. That is the runaway the exam warns about. The summary on the right gives the uses: series motors for starters, actuators and landing gear; shunt motors for fans, pumps and motor-generators.
Part 3 · Direction
Reversing a DC motor Reverse either the armature current or the field: the motor reverses Reverse both , for example by swapping the supply leads of a wound motor: no change So a reversible motor switches the armature or the field separately The split-field series motor has two field windings wound in opposite senses : select one to choose the direction This is how most actuator motors are reversed Normal N S + clockwise Current reversed N S − anticlockwise Field reversed S N + anticlockwise Both reversed S N − clockwise Split-field series motor: pick one of two opposite field windings
Chapter 7 · DC Motors and Actuators
14
e-books by eatpl.in · © 2026 · Do not copy or distribute
Many aircraft motors have to run both ways: an actuator that opens a valve must also close it. From the left-hand rule, we can reverse a DC motor by reversing either the current in the armature or the direction of the field. But if we reverse both, the motor keeps turning the same way. This catches people out: with a series or shunt wound motor, simply swapping over the two supply leads reverses the armature current and the field current together, so nothing changes. A reversible motor must therefore switch the armature or the field on its own. The neat solution used in most actuators is the split-field series motor. It has two series field windings, wound in opposite senses, so each produces flux in the opposite direction. Only one is energised at a time, and the selector switch chooses which, so it chooses the direction of rotation.
Part 3 · Two jobs in one
The starter-generator One compound-wound machine permanently geared to a turbine engine: starts it, then generates Starting: works as a compound motor ; the shunt field is fed via a field changeover relay Running: starter circuit isolated, relay drops out and connects the shunt field to the voltage regulator Typical output: 300 A at 28 V (8.4 kW) Saves weight and complexity, but poor output at low rpm : suits turbinesTwin installations are load-shared by an equalising circuit turbine engine gearbox starter- generator START: power in, turns the engine RUN: 28 V out to the bus bar Typical: 300 A × 28 V = 8.4 kW + one unit instead of two: less weight − poor output at low rpm: suits turbines
Chapter 7 · DC Motors and Actuators
15
e-books by eatpl.in · © 2026 · Do not copy or distribute
Many turboprops and small turbine aircraft use a starter-generator: one machine that starts the engine and then becomes its generator. It is a compound-wound machine, with a series field, a shunt field, one armature and a commutator, permanently coupled to the engine through a drive shaft and gears. For starting it works as a compound motor, with the shunt field supplied through a field changeover relay. Once the engine is running, the starter circuit is isolated, the changeover relay drops out, and its contacts connect the shunt field to a voltage regulator. The machine is now a conventional DC generator, and once its output reaches the regulated level it is connected to the bus. A typical unit gives three hundred amps at twenty-eight volts, eight point four kilowatts. One device instead of two saves weight and complexity, but it cannot give full output at low rpm, so it suits turbines. On twins, the generators share the load through an equalising circuit that matches their voltages.
Part 3 · Starter-generator
Motor mode and generator mode Motor mode: starting the engine M engine drive shaft turns the engine series field C/O relay shunt field + battery or ground power Generator mode: engine running G engine drive shaft driven by engine series field regulator shunt field to bus bar via C/O relay The field changeover relay decides the role of the shunt field: motor field for starting, regulated generator field once the engine runs.
Chapter 7 · DC Motors and Actuators
16
e-books by eatpl.in · © 2026 · Do not copy or distribute
Here are the two modes side by side. On the left, motor mode. Power from the battery or a ground power unit flows through the series field and the armature, and the shunt field is energised through the field changeover relay. The machine works as a compound motor, with the high starting torque of its series field, and it turns the engine over through the drive shaft until the engine can run by itself. On the right, generator mode. The engine is now driving the machine. The starter circuit has been isolated, and the changeover relay has dropped out, connecting the shunt field to the voltage regulator. The relay contacts also let current flow through the shunt winding to give the field its initial excitation. From then on the regulator controls the field current, and the output goes to the bus bar once it reaches the regulated voltage, just like any other DC generator.
Part 4 · Actuators
Remote control of things the crew cannot reach Most equipment is out of the crew's reach, so it is worked remotely by electrical actuators :
Solenoid actuators A coil pulls an iron plunger: valves open under magnetic attraction . Used for hydraulic and pneumatic selector valves .
Rotary actuators A small reversible motor turns an output shaft through a gearbox . Used for fuel valves and air and oil shut-off valves .
Linear actuators A reversible motor drives a screw jack to push or pull a ram. Used for flaps , landing gear , trim tabs and cooler shutters .
Chapter 7 · DC Motors and Actuators
17
e-books by eatpl.in · © 2026 · Do not copy or distribute
On a modern aircraft most of the equipment is tucked away where the crew cannot reach it, so it has to be worked remotely, and electrical actuators do that job. They fall into two main groups. Solenoid actuators use a coil to pull an iron plunger, so a valve opens by magnetic attraction; they are used to switch hydraulic and pneumatic selector valves. Motor actuators come in two kinds. Rotary actuators have a small reversible motor turning an output shaft through a gearbox, and they open and close fuel valves, fuel cocks, and air and oil shut-off valves. Linear actuators have a reversible motor driving a screw jack, which pushes or pulls a ram, for anything needing a push-pull action: flaps, landing gear, trim tabs, and inching controls for oil cooler shutters. Let us look at each in turn.
Part 4 · Solenoid actuators
Solenoid actuators: a pull on a valve A coil around a movable iron plunger , held on its seat by a spring Energise the coil: the plunger is pulled in and the valve opens De-energise: the spring returns it and the valve shuts Quick, simple, two positions only: open or shut Used to control hydraulic and pneumatic selector valves De-energised: shut spring holds it shut Energised: open coil glows when energised Used to switch hydraulic and pneumatic selector valves
Chapter 7 · DC Motors and Actuators
18
e-books by eatpl.in · © 2026 · Do not copy or distribute
The solenoid actuator is the simplest electrical actuator. A coil surrounds a movable iron plunger, which a return spring holds down on its seat, keeping the valve shut. When the coil is energised, its magnetic field pulls the plunger up into the coil, the valve lifts off its seat and the hydraulic fluid flows. When the coil is de-energised, the spring pushes the plunger back down and the valve shuts again. It is quick and simple, but it has only two positions, open or shut, and it can only exert a limited force over a short distance. So solenoid actuators are used to control hydraulic and pneumatic selector valves, where a small electrical signal from the flight deck switches a powerful fluid system. Remember from chapter two that the solenoid has a moving core, while a relay has a hinged armature.
Part 4 · Rotary actuators
Rotary actuators: opening a fuel valve A small reversible motor turns the output shaft through a reduction gearbox Used for fuel valves (fuel cocks) and air and oil shut-off valves Controlled by an ON/OFF or OPEN/SHUT selector switch Two limit micro-switches control the extent and direction of travel and work the indicators One limit switch is always closed ; they change over at the end of travelmotor reduction gearbox fuel line valve (open) OPEN limit CLOSE limit doll's eye: in line = OPEN Fuel valves, air and oil shut-off valves OPEN/SHUT switch; limit switches end the travel
Chapter 7 · DC Motors and Actuators
19
e-books by eatpl.in · © 2026 · Do not copy or distribute
A rotary actuator uses a small reversible motor to turn an output shaft through a reduction gearbox. Typical jobs are fuel valves, often called fuel cocks, and air and oil shut-off valves, all of which are either open or shut. The pilot controls it with an on-off or open-shut selector switch. Watch the sequence. The pilot selects OPEN, and current flows through the closed open limit switch to the motor. The motor spins, the gearbox turns its high speed into a slow, powerful rotation, and the valve swings open until the fuel flows. At the end of travel, the moving mechanism trips the limit micro-switch. It breaks the supply to the motor, which stops, and it completes the circuit to the position indicator in the cockpit. The two limit switches control both the extent and the direction of travel. One of them is always closed, ready for the next selection, and they change over at the end of each travel.
Part 4 · Inside the actuator
Rotary actuator circuit 28 V DC selector OPEN CLOSE open limit switch open field close limit switch close field brake coils M clutch reduction valve doll's eye one limit switch is always closed Limit switch opens at the end of travel: motor stops, brake on, indicator lit Selector → limit switch → field winding → brake coils → armature. The clutch and reduction gear sit between the motor and the valve; the doll's eye shows the position.
Chapter 7 · DC Motors and Actuators
20
e-books by eatpl.in · © 2026 · Do not copy or distribute
This is the inside of a typical rotary actuator. The twenty-eight volt supply goes to the open-close selector switch. From there, the open selection runs through the open limit switch to the open field winding, and the close selection through the close limit switch to the close field winding. Both paths then pass through the brake coils and the armature to earth. So selecting OPEN energises the open field, releases the brake and runs the motor one way; selecting CLOSE runs it the other way. On the mechanical side, the motor drives through a clutch and a reduction gear to the valve. When the valve reaches the end of its travel, the limit switch for that direction opens, the motor stops and the brake snaps on, and the indicator, here a doll's eye, shows the new position. The other limit switch has already closed, so the circuit is ready for the opposite selection.
Part 4 · Linear actuators
Linear actuators and inching control Reversible motor → reduction gear → screw jack , which extends or retracts a ram For push-pull jobs: flaps , landing gear , trim tabs , oil cooler shutters Full travel: a selector switch; limit switches open to stop the motor at each end and work the indicators Small movements (trim): a spring-loaded, self-centring OFF switch: inching control Mid-travel, both limit switches are closed , so the inching switch can reverse the motor at any point motor gear extend retract screw jack and ram retract limit extend limit Used for: flaps, landing gear, trim tabs, cooler shutters UP DN Inching (trim) switch: spring-loaded to centre OFF; hold it and the ram creeps mid-travel: both limit switches closed
Chapter 7 · DC Motors and Actuators
21
e-books by eatpl.in · © 2026 · Do not copy or distribute
A linear actuator turns rotation into a straight push or pull. A small reversible motor drives, through a reduction gear, a screw jack: as the screw turns, it winds a ram in or out. Linear actuators work flaps, landing gear and trim tabs, and inching controls for oil cooler shutters. For full up or down movement, the pilot uses a selector switch, and the motor runs until the ram reaches full travel, where a limit switch opens and stops the motor, and also works the position indicator. Here the ram extends until its limit switch opens and it stops. For small adjustments, such as trimming, a different switch is used: spring-loaded to a self-centring OFF position. Hold it one way and the motor runs in that sense; let go and it stops. That is inching control. Whenever the ram is between its end stops, both limit switches are closed, so the inching switch can drive it either way from any position.
Part 4 · Stopping exactly
Actuator brakes and clutches Many actuators have an electromagnetic brake to prevent over-travel when the motor stops Brakes are spring-loaded ON when the motor is de-energised The brake solenoid is in series with the armature : released the instant power is applied Power off: the brake comes on at once: no over-run or creep Friction (slipping) clutches in the drive protect against mechanical overload Power OFF: brake ON solenoid springs clamp the disc Power ON: brake released solenoid solenoid pulls pads clear Brake solenoid in series with the armature: released the instant power is applied, on again the instant it is cut: no over-run or creep Friction (slipping) clutch: protects against mechanical overload, e.g. a jammed load
Chapter 7 · DC Motors and Actuators
22
e-books by eatpl.in · © 2026 · Do not copy or distribute
A motor that is switched off does not stop at once; its armature keeps spinning for a moment, and through the gearbox that could drive the valve or flap past where it should stop. So many actuators have an electromagnetic brake. The designs vary, but in every case the brake is spring-loaded to the on condition whenever the motor is de-energised. The brake solenoid is connected in series with the armature, so the instant power is applied to the motor, the solenoid pulls the brake off, and the instant the power is cut, for example when a limit switch opens, the springs clamp the brake on again. That prevents over-run and creep. Actuators also have a friction clutch, sometimes called a slipping clutch, between the motor and the gearing. If the load jams or the actuator is overloaded mechanically, the clutch slips rather than letting the motor wreck the gears or the structure.
Part 4 · Telling the pilot
Position indicators The pilot must know the position, and also whether the actuator is in transit or has lost power .
Press-to-test light Press the lens to test the filament without moving the actuator.
Doll's eye A bar in line with the flow line for open , across it for shut.
Prism and flag Show OPEN , SHUT or a striped no-power flag.
Graduated scale For linear actuators that stop between limits, such as trim.
Chapter 7 · DC Motors and Actuators
23
e-books by eatpl.in · © 2026 · Do not copy or distribute
Pilots need to know where an actuator is, and also whether it is still travelling, or has lost its power supply. The simplest indicator is a light, and these are usually press-to-test: pressing the front glass of the lamp tests the filament and its supply, without operating the actuator. Electromagnetic indicators were introduced to replace simple lamps. The doll's eye shows a bar which lies in line with the painted flow line on the panel when the valve is open, and across it when shut. Prism and flag indicators show the words OPEN or SHUT, or a striped flag when there is no power. These flow lines join the switches, valves and indicators into a little picture of the system, so the pilot can see at a glance what is open. Rotary actuators on fuel and oil valves only need open or shut. Linear actuators that stop between their limits, like trim, use a position indicator with a graduated scale.
Part 4 · Putting it together
The split-field series actuator A high-speed reversible motor with two series field windings giving opposite flux Only one is energised at a time: that sets the direction OPEN selected: supply through the open limit switch , open field and brake coils to the armature; the brake releases At full travel the open limit switch breaks the motor supply and makes the OPEN indicator circuit The close limit switch has already set up the close circuit Brake on at once; a slipping clutch guards against overload 28 V selector OPEN limit sw. open field CLOSE limit sw. close field brake M Two field windings wound in opposite senses; only one energised at a time = direction Limit switches in series with the fields stop it at the end
Chapter 7 · DC Motors and Actuators
24
e-books by eatpl.in · © 2026 · Do not copy or distribute
Let us bring it all together in the split-field series actuator, the standard design for fuel valves, cooler shutters and trim tabs. It uses a high-speed reversible series motor driving through a wide-ratio gear train. The motor has two series field windings wound differentially, so each produces flux in the opposite direction, and only one is ever energised. Limit switches, worked by the moving load, are fitted in series with the field windings. Suppose OPEN is selected. Current flows through the open limit switch, the open field and the brake coils to the armature. The brake releases and the motor runs. At the end of travel, the open limit switch trips: it breaks the supply to the motor and makes the circuit to the OPEN indicator. Meanwhile the close limit switch has set up the close circuit, ready for a CLOSE selection. The brake comes on the moment the supply is broken, and a slipping clutch protects against mechanical overload.
Summary
DC motors and actuators: the essentials Motor effect Current in a field feels a force, F = BIL . Left hand : First Field, seCond Current, thuMb Motion.
Commutator Reverses the loop current each half turn to keep the torque one way. AC→DC: commutator or rectifier ; DC→AC: inverter .
Back EMF ∝ speed, opposes supply, always less than it. Huge starting current ; slow start resistor in series with the armature.
Series motor High starting torque, speed varies with load, overspeeds off load . Starters, actuators, gear.
Shunt motor Constant field, constant speed (about 10%). Fans, pumps, motor-generators.
Reversing Reverse armature or field, never both. Split-field series motors in actuators.
Starter-generator Compound machine on turbines: motor to start, generator to run. 300 A at 28 V.
Actuators Rotary: fuel cocks. Linear: flaps, gear, trim, inching . Limit switches , spring-on brakes, slipping clutches , doll's eyes.
Chapter 7 · DC Motors and Actuators
25
e-books by eatpl.in · © 2026 · Do not copy or distribute
Let us sum up. A current-carrying conductor in a magnetic field feels a force equal to B I L, and the left-hand rule gives its direction. The commutator keeps a motor's torque one way by reversing the loop current each half turn; remember that AC to DC needs a commutator or a rectifier, and DC to AC an inverter. A turning motor generates a back EMF proportional to speed, which limits its current, so the starting current is very large, and a slow start resistor may be used. Series motors have high starting torque but run away off load; shunt motors run at nearly constant speed. To reverse a motor, reverse the armature or the field, never both. The starter-generator is a compound machine that starts a turbine and then generates. And actuators, rotary for valves and linear for flaps, gear and trim, use limit switches, spring-on brakes, slipping clutches and indicators such as the doll's eye.