Chapter eight puts the pieces of the DC system together. You already know how generators, batteries, relays and circuit breakers work. Now we see how an aircraft is wired, how the generator is controlled and kept from running the battery down, how the pilot monitors it all with ammeters and voltmeters, and how bus bars share the power out so that the most important services keep running when something fails. We finish with load shedding and the drill for a generator failure, which is a favourite exam topic.
Roadmap
From one wire to a whole power system 1 · Wiring Two-wire and earth-return circuits, and what shorts and open circuits do in each.
2 · Control Regulator , overvoltage unit, reverse current cut-out , differential cut-out, inverters.
3 · Monitoring Moving-coil meters, shunts and multipliers , centre-zero ammeter and load meter .
4 · Distribution Bus bars , vital, essential and non-essential loads, split bus , load shedding, generator failure.
Chapter 8 · Aircraft DC Power Systems
2
e-books by eatpl.in · © 2026 · Do not copy or distribute
Here is our route through the chapter. In part one we look at how a load is wired to its supply, either with two wires or with the metal airframe as the return, and what happens in each case when a wire shorts or breaks. Part two covers the control equipment between the generator and the bus bar: the voltage regulator, the overvoltage unit, the reverse current cut-out, the differential cut-out used on twins, and the rectifiers and inverters. Part three is about monitoring: how moving-coil meters work, how they are connected, and how to read a centre-zero ammeter and a load meter. Part four is distribution: bus bars, the three classes of load, the split bus bar system, load shedding and what to do when a generator fails.
Part 1 · The power system
Sources, control and the bus bar Single-engine: one generator or alternator plus its control and indicating equipment On line = switched into the system and actually supplying powerMulti-engine: two or more sources connected in parallel onto the bus The battery starts the engine and is the standby source The system's ampere capacity is set by the number of power-consuming devices fitted Single engine Engine Alternator or generator Control regulator, cut-out BUS battery "On line" = switched in and actually supplying Twin engine: generators in parallel G Gen 1 control G Gen 2 control common bus bar Both sources feed the same bus at the same voltage
Chapter 8 · Aircraft DC Power Systems
3
e-books by eatpl.in · © 2026 · Do not copy or distribute
Every aircraft DC power system has the same building blocks. The engine drives a generator or an alternator, which is the main source. Between the source and the bus bar sits control equipment that regulates the voltage and connects or disconnects the source. The bus bar then feeds the individual loads, and a battery sits on the bus to start the engine and to stand by if the main source fails. We say a generator is on line when it has been switched into the system and is actually supplying power, not merely turning. On a multi-engine aircraft two or more generators are connected in parallel onto the same bus, so they share the load at the same voltage. Finally, the ampere capacity of the system, meaning how much current it must be able to deliver, is decided by how many power-consuming devices are fitted.
Part 1 · Wiring
Two-wire or earth-return? Two-wire (dipole) : a positive wire out and a separate negative wire backNeeded where the airframe is non-conductive (wood, composite) Single-pole (unipole, earth return ): the metal airframe is the negative conductorSource negative and each load's negative go to airframe earth Earth return is the most common on metal aircraft: half the wiring, less weight Two-wire (dipole) non-conductive airframe + − positive (live) wire negative return wire 2 wires per load Single-pole (earth return) metal airframe + − return through the structure 1 wire per load
Chapter 8 · Aircraft DC Power Systems
4
e-books by eatpl.in · © 2026 · Do not copy or distribute
Current needs a complete circuit, out from the positive side of the source, through the load and back to the negative side. There are two ways of providing the return. In a two-wire, or dipole, system every load has its own positive wire from the bus bar and a separate negative wire back to the source. That is essential where the airframe is made of wood or composite and cannot carry current. On a metal aircraft we can save a great deal of wire. In the single-pole system, also called unipole or earth return, the negative side of the generator and the negative side of every load are simply connected to the airframe, and the metal structure carries the current back. That halves the wiring and saves weight, so it is the most common system on metal aircraft. Remember the names: dipole means two conductors; earth return means the structure is the return path.
Part 1 · Earth return
Current round an earth-return circuit metal airframe: the common negative return bus bar battery circuit breaker current returns through the structure One wire per load: the structure carries every load's return current back to the battery negative.
Chapter 8 · Aircraft DC Power Systems
5
e-books by eatpl.in · © 2026 · Do not copy or distribute
Let us follow the current round an earth-return circuit. The battery positive terminal feeds the copper bus bar. From the bus, each load has its own feed through a circuit breaker, so the loads are all in parallel and each one gets the full bus voltage. When the loads are switched on, current flows down through each breaker and load. Then, instead of a long negative wire back to the battery, each load has only a short lead to the nearest piece of airframe. The metal airframe carries the return current along the structure to the point where the battery negative is earthed. Notice that the structure is part of every circuit at once, which is why its joints must be well bonded, a topic for the next chapter. A bad joint in the structure means a bad return for every load beyond it.
Part 1 · Faults
Short circuits and open circuits Fault Earth-return (single-pole) Two-wire (dipole) Live wire touches structure Short circuit to earth: huge current, the fuse blows or the breaker tripsNothing happens on its own: the structure is not part of the circuit Live and return wires touch (no return wire) Short circuit : fuse blows, the component stops working Conductor broken (open circuit)No complete path: the load does not operate ; no fuse blows Same: the load does not operate Load's earth lead broken Open circuit: the load does not operate — Fuse position In the positive (live) lead, near the bus In the positive lead
A short means too much current (protection operates). An open circuit means no current (the load just stops).
Chapter 8 · Aircraft DC Power Systems
6
e-books by eatpl.in · © 2026 · Do not copy or distribute
Exam questions love to ask what a fault does in each type of circuit. In an earth-return system the whole airframe is negative. So if the live wire chafes through its insulation and touches the structure, it is connected straight to negative with almost no resistance in between. That is a short circuit to earth: a very large current flows, and the fuse blows or the circuit breaker trips. In a two-wire system the same chafe does nothing on its own, because the structure is not part of the circuit; but if the live and return wires touch each other, that is a short, the fuse blows and the component stops working. An open circuit is the opposite: a broken conductor anywhere in the loop means no current at all, so the load simply does not operate, and no fuse blows. The fuse always goes in the live, positive lead.
Part 2 · Sources
Generator or alternator? Both turn mechanical energy into electrical energy by electromagnetic induction DC generator : rotating armature, stationary field, commutator Alternator : rotating field, stationary armature; AC turned to DC by diodes in the end frame A generator gives full output only at about half engine speed or more An alternator gives useful output even at idle : one reason light aircraft use them 0 25 50 75 100 0 20 40 60 80 100 engine speed (% of maximum rpm) available output (%) idle alternator DC generator full output at ≈ half engine speed Illustrative shapes, not a particular machine
Chapter 8 · Aircraft DC Power Systems
7
e-books by eatpl.in · © 2026 · Do not copy or distribute
The main source is either a DC generator or an alternator, and both convert mechanical energy into electrical energy by electromagnetic induction. The DC generator has a rotating armature inside a stationary field, and a commutator to turn the alternating voltage induced in the armature into DC. The alternator does it the other way round: the field rotates and the armature is stationary, so it produces AC, which a set of diodes in the alternator end frame rectifies into DC. Most modern light aircraft have a DC system powered by an alternator. One big reason is shown on the graph. A generator gives little useful output at idle and only reaches its full output at roughly half engine speed, even though it is geared to turn faster than the engine. An alternator gives useful output at low speed, so the battery keeps charging while you taxi.
Part 2 · Control
The voltage regulator Keeps the output constant whatever the engine rpm or electrical load Works by controlling the field current (generator) or exciter field (alternator) Engine speed cannot be used: the generator turns with the engine 14 V setting for a system with a 12 V battery 28 V setting for a system with a 24 V battery Set above battery voltage so the battery is charged Only practical control: vary the FIELD current G to cut-out and bus senses volts Voltage regulator field winding field current Volts rise → less field current; volts fall → more Battery System (regulated) voltage 12 V 14 V light aircraft 24 V 28 V most larger types
Chapter 8 · Aircraft DC Power Systems
8
e-books by eatpl.in · © 2026 · Do not copy or distribute
The voltage a generator produces depends on how fast it turns and how strong its magnetic field is. We cannot control the speed, because the generator is driven by the engine, and the engine speed is set by what the pilot wants. So the only practical control is the strength of the field. The voltage regulator senses the output voltage and varies the current in the field winding of a generator, or in the exciter field of an alternator. If the voltage starts to rise, it cuts the field current; if the voltage falls, it increases it. The result is a constant output whatever the engine rpm or the electrical load. Typical settings are fourteen volts for a system with a twelve-volt battery, and twenty-eight volts for a system with a twenty-four-volt battery. The regulated voltage is deliberately higher than the battery so that the battery is kept charged.
Part 2 · Protection
The overvoltage protection unit Protects against a failed voltage regulator letting the voltage run away High voltage drives high current (V = IR): overheating and damaged equipment Trips at typically 16.5 V in a 14 V system It opens the field circuit : generator output falls to zero It may also open the cut-out , to prevent reverse current 10 12 14 16 18 0 2 4 6 8 10 time (s) bus voltage (V) trip setting 16.5 V regulator fails field opened: generator output → 0 battery holds the bus regulator fails volts climb OVP opens field output → 0 14 V system: normal 14 V, trip about 16.5 V; it may also open the cut-out
Chapter 8 · Aircraft DC Power Systems
9
e-books by eatpl.in · © 2026 · Do not copy or distribute
What if the voltage regulator itself fails, for example with its field control stuck fully on? The generator voltage would climb well above normal, and because current equals voltage divided by resistance, every load would draw more current and overheat. Bulbs blow, avionics are damaged and the battery is badly overcharged. The overvoltage protection unit guards against this. It watches the output voltage, and if it rises to its trip setting, typically sixteen and a half volts in a fourteen-volt system, it disconnects the field circuit. With no field, the generator output falls to zero, and the system is safe. The graph shows a typical event: steady at fourteen volts, the regulator fails, the voltage climbs, the unit trips at sixteen and a half, and the bus falls back to the battery voltage. The unit may also open the cut-out, to stop reverse current flowing into the dead generator.
Part 2 · The cut-out
The reverse current cut-out relay Connects the generator to the bus when its voltage has built up enough Voltage (shunt) coil : many turns of thin wire, across the outputCurrent (series) coil : few turns of thick wire, in series with the outputA spring holds the contacts open until the voltage coil pulls them shut Fitted in series with the generator output; may be part of the regulator Contacts shown OPEN (spring) series coil few thick turns shunt (voltage) coil many thin turns hinge contacts spring holds open G generator to bus and battery across the output Closed by rising voltage (shunt coil); opened by reverse current (series coil)
Chapter 8 · Aircraft DC Power Systems
10
e-books by eatpl.in · © 2026 · Do not copy or distribute
The reverse current cut-out is the switch that puts a DC generator on line. It has two coils on one iron core. The voltage coil, also called the shunt coil, has many turns of thin wire and is connected across the generator output, so its pull depends on generator voltage. The current coil, or series coil, has a few turns of thick wire and carries the full output current. Above the core is a hinged armature carrying one contact, and a spring holds the contacts open. As the engine starts, generator voltage builds and the voltage coil grows stronger. At about twenty-six volts in a twenty-eight-volt system its pull beats the spring, the armature closes, and current flows out to the loads and the battery. That current through the series coil adds to the pull. When the generator voltage falls below the battery, current tries to flow backwards, the series coil now opposes the shunt coil, and the spring snaps the contacts open.
Part 2 · The cut-out
Closed by rising voltage, opened by reverse current 0 8 16 24 32 0 2 4 6 8 10 12 14 time (s) volts contacts CLOSED: generator on line battery 24 V closes ≈ 26 V (rising voltage) opens: generator below battery (reverse current) regulated 28 V engine start shut-down No cut-out is needed with an alternator : its rectifier diodes already block reverse current.
Chapter 8 · Aircraft DC Power Systems
11
e-books by eatpl.in · © 2026 · Do not copy or distribute
This graph shows the cut-out working through one engine start and shut-down in a twenty-eight-volt system. The dashed line is the battery at twenty-four volts. As the engine starts, the generator voltage rises. The cut-out stays open until the generator is comfortably above the battery, at about twenty-six volts, and only then closes. Closing a little above battery voltage makes sure current will flow out of the generator into the battery and loads. The generator then sits on line at its regulated twenty-eight volts. At shut-down the generator voltage falls. As soon as it drops below the battery voltage, current tries to flow back from the battery into the generator. That reverse current opens the contacts. So remember the rule: closed by rising voltage, opened by reverse current. If the contacts stuck shut, the battery would discharge through the generator windings and could burn the generator out.
Part 2 · Conversion
Rectifiers and inverters Rectifier diodes in the alternator end frame turn AC into DC Low resistance one way, high resistance the other : current out, not back in Static inverter : solid-state, typically 18–30 V DC in , 115 V AC at 400 Hz outContains oscillators, transistors, diodes, capacitors and transformers Rotary inverter : a constant-speed DC motor driving an alternator Rectifier: AC → DC (one-way valve) 3~ alternator AC (3 phases) rectifier 6 diodes DC + DC − Current flows out freely; reverse flow is blocked, so no cut-out is needed Inverters: DC → AC Static (solid state) 18–30 V DC in oscillator transistors transformer 115 V 400 Hz Rotary: a constant-speed DC motor drives an alternator M ~ constant-frequency AC
Chapter 8 · Aircraft DC Power Systems
12
e-books by eatpl.in · © 2026 · Do not copy or distribute
Two kinds of converter appear in DC systems. A rectifier turns AC into DC. In an alternator, a bridge of diodes in the end frame does this job. A diode has a very low resistance in one direction and a very high resistance in the other, so current can flow out of the alternator to the bus but cannot flow back in from the battery. That is why an alternator system needs no reverse current cut-out. An inverter does the opposite: it turns DC into AC, for instruments and avionics that need alternating current. A static inverter is a solid-state box of oscillators, transistors, diodes, capacitors and transformers. A typical one takes eighteen to thirty volts DC and delivers one hundred and fifteen volts AC at four hundred hertz, at a constant frequency. The older rotary inverter uses a constant-speed DC motor to drive a small alternator, which also gives constant-frequency AC.
Part 2 · Twins
The differential cut-out Used on multi-engine aircraft with generators in parallel Prevents circulating currents between a generator already on line and one coming on line The oncoming generator connects only when it is 2 % above the bus The 2 % is measured between the oncoming generator and the battery bus bar Worked example: bus 28.00 V → closes at 28.56 V common bus (battery bus) 28.00 V G1 on line G2 coming on line differential cut-out bus 28.00 V G2 = 27.80 V: stays OPEN G2 = 28.56 V: CLOSES bars start at 27 V +2 % = 28.56 V
Chapter 8 · Aircraft DC Power Systems
13
e-books by eatpl.in · © 2026 · Do not copy or distribute
On a twin, the second generator must be connected to a bus that is already live. If it were switched in while its voltage was lower than the bus, the generator already on line would drive current into it, and current would circulate between the two machines instead of feeding the loads. The differential cut-out prevents this. It compares the voltage of the oncoming generator with the voltage of the battery bus bar, and it only closes when the oncoming generator is two per cent higher. Let us work an example. The first generator holds the bus at twenty-eight volts. Two per cent of twenty-eight is zero point five six, so the second generator must reach twenty-eight point five six volts before its contacts close. At twenty-seven point eight volts it stays off line. Exam questions call this the device that prevents circulating currents.
Part 2 · Pilot controls
Warning light and master switch The generator (alternator) warning light means output has fallen below battery voltage It is linked to the cut-out position or a reverse current detector The master (field) switch lets the pilot electrically isolate the generator Opening it breaks the field (or exciter) circuit: output falls to its residual value, nearly zero The battery master isolates the battery from the bus Warning light ALT ON when generator volts < battery volts driven by the cut-out position or a reverse current detector Also look for: load meter at zero, or centre-zero ammeter showing discharge Master switch BAT ALT ON = upper half pressed ALT off: breaks the field / exciter circuit; output falls to its residual value (≈ 0 V) BAT off: opens the battery master contactor; the battery is isolated from the bus
Chapter 8 · Aircraft DC Power Systems
14
e-books by eatpl.in · © 2026 · Do not copy or distribute
The pilot has two important items here. First, the generator or alternator warning light. It comes on when the generator voltage has fallen below the battery voltage, in other words when the generator is no longer feeding the bus. It is usually worked by the cut-out position or by a reverse current detector, so in practice it lights whenever the cut-out is open. Second, the master switch. On many light aircraft it is split into a battery half and an alternator half. Switching the alternator half off breaks the field circuit of a generator, or the exciter circuit of an alternator. With no field current the output falls to its residual level, which is virtually zero, so the failed machine is electrically isolated and safe. Switching the battery half off opens the battery contactor and isolates the battery from the bus bar.
Part 3 · Monitoring
The moving-coil meter A coil on a pivoted former turns between the poles of a permanent magnet A fixed soft-iron core inside the coil makes the field radial and even Two hairsprings restrain the coil and carry current in and out Deflection is proportional to current : an evenly divided scale A soft-iron case screens it from stray magnetism 0 50 100 even scale: deflection ∝ current N S permanent magnet soft-iron core moving coil hairspring
Chapter 8 · Aircraft DC Power Systems
15
e-books by eatpl.in · © 2026 · Do not copy or distribute
Most aircraft ammeters and voltmeters use the moving-coil movement. A permanent magnet has two pole pieces, and between them sits a fixed soft-iron core. Around the core is a light coil wound on a former, mounted on a spindle so it can turn, and the pointer is fixed to it. When current flows through the coil, its magnetic field reacts with the magnet's field and the coil turns, swinging the pointer across the scale. Two fine hairsprings resist the turning and also carry the current into and out of the coil. The greater the current, the further the coil turns before the springs balance it, so deflection is proportional to current and the scale is evenly divided. When the current stops, the springs bring the pointer back to zero. The whole movement sits in a soft-iron case, which screens it from stray magnetic fields.
Part 3 · Monitoring
Connecting ammeters and voltmeters Ammeter : very low resistance, connected in series so the load current passes through itVoltmeter : very high resistance, connected in parallel across the two pointsAmmeter range extended by a shunt (low R) in parallel with the movement Voltmeter range extended by a multiplier (high R) in series Usually one ammeter per power source and one voltmeter with a selector per DC system + A V in SERIES across the load Ammeter very LOW resistance in series with the load range: SHUNT in parallel Voltmeter very HIGH resistance in parallel (across) range: MULTIPLIER in series
Chapter 8 · Aircraft DC Power Systems
16
e-books by eatpl.in · © 2026 · Do not copy or distribute
How a meter is connected follows from what it measures. An ammeter measures the current through a circuit, so the current must pass through it: it goes in series. To avoid upsetting the circuit it must have a very low resistance. A voltmeter measures the potential difference between two points, so it is connected across them, in parallel. It must have a very high resistance, so it takes almost no current itself. Put an ammeter in parallel by mistake and its low resistance makes it a short circuit; put a voltmeter in series and almost no current flows. Both use the same delicate movement, so to measure large values we add a resistor. The ammeter gets a shunt in parallel, the voltmeter gets a multiplier in series. A twin normally has one ammeter for each generator and one voltmeter that can be switched to read either generator or the battery.
Part 3 · Worked example
Sizing a shunt and a multiplier Movement: 10 mA for full-scale deflection, resistance 5 Ω Ammeter to 50 A : 49.99 A must bypass the meter through the shunt Shunt = 0.05 V ÷ 49.99 A ≈ 0.001 Ω (one milliohm) Voltmeter to 30 V : total R = 30 ÷ 0.01 = 3000 Ω Multiplier = 3000 − 5 = 2995 Ω Ammeter to 50 A: shunt in parallel M 50 A movement 10 mA, 5 Ω shunt ≈ 0.0010 Ω Meter volts at FSD 0.01 × 5 = 0.05 V Shunt current 50 − 0.01 = 49.99 A R(shunt) = 0.05 V ÷ 49.99 A ≈ 0.001 Ω (about 1 milliohm) Voltmeter to 30 V: multiplier in series M + − multiplier 2995 Ω Total R for FSD 30 ÷ 0.01 = 3000 Ω Multiplier 3000 − 5 = 2995 Ω Shunt: tiny R, in parallel. Multiplier: large R, in series.
Chapter 8 · Aircraft DC Power Systems
17
e-books by eatpl.in · © 2026 · Do not copy or distribute
Let us put numbers on shunts and multipliers. Our meter movement gives full-scale deflection at ten milliamps and has a resistance of five ohms. At full scale the voltage across it is ten milliamps times five ohms, which is zero point zero five volts. To make it read fifty amps, the shunt in parallel must carry everything except the ten milliamps, so forty-nine point nine nine amps, with that same zero point zero five volts across it. Dividing, the shunt is about zero point zero zero one ohms, one milliohm: a very low resistance, as expected. To make the same movement into a thirty-volt voltmeter, the total resistance must limit the current to ten milliamps at thirty volts. Thirty divided by zero point zero one is three thousand ohms. The movement provides five, so the series multiplier is two thousand nine hundred and ninety-five ohms: a very high resistance.
Part 3 · Reading the ammeters
Centre-zero ammeter and load meter Centre-zero (charge / discharge) ammeter −60 −30 0 +30 +60 AMPS A + right of zero: alternator supplying and charging the battery − left of zero: battery discharging; alternator not coping Fitted between the battery and its bus bar: it measures current into or out of the BATTERY Left-zero ammeter (load meter) 0 10 20 30 40 50 60 LOAD A Reads the actual load (current drawn) from the alternator Zero = alternator not supplying: battery is the only source Fitted in the generator / alternator output: one per power source
Chapter 8 · Aircraft DC Power Systems
18
e-books by eatpl.in · © 2026 · Do not copy or distribute
There are two types of ammeter in DC systems, and you must not confuse them. The centre-zero ammeter, or charge-discharge ammeter, is fitted between the battery and its bus bar, so it tells you about current into or out of the battery. A reading to the right of zero means the alternator is working, supplying the loads and charging the battery. A reading to the left of zero means the battery is discharging, so the alternator is not supplying the system. The left-zero ammeter, called the load meter, sits in the generator or alternator output. It shows the actual current the system is drawing from that source. If the load meter reads zero, the alternator is supplying nothing, and in a single-engine aircraft the battery is now the only source of power. On a twin there is one load meter for each generator.
Part 3 · Interpreting
What the ammeter is telling you Situation Centre-zero ammeter Load meter Master on, before engine start Small discharge (battery feeding loads) Zero Just after start Large charge , falling as the battery recovers High, then settles Normal cruise Small charge, near zero Steady: the total load Alternator failed Discharge , warning light onZero , warning light onEngine stopped, ammeter shows +5 A charge Impossible: nothing can charge the battery → defective ammeter Shows no charge , yet the battery stays charged Charging must be happening → defective ammeter
The voltmeter shows the system "pressure" both before and after the cut-out closes.
Chapter 8 · Aircraft DC Power Systems
19
e-books by eatpl.in · © 2026 · Do not copy or distribute
Let us interpret some readings. With the master switch on before engine start, the battery is feeding the loads, so the centre-zero ammeter shows a small discharge and the load meter reads zero. Just after start the alternator recharges the battery, so the centre-zero ammeter shows a large charge that dies away over a few minutes. In cruise it sits just on the charge side of zero. If the alternator fails, the centre-zero ammeter swings to discharge, the load meter drops to zero and the warning light comes on. Two trap questions now. After engine shut-down the ammeter shows plus five amps of charge: nothing can be charging the battery, so the ammeter is defective. Or the ammeter shows no charge, yet the battery stays charged: charging must be happening, so again suspect the ammeter. Finally, the voltmeter reads system pressure both before and after the cut-out closes.
Part 4 · Distribution
Bus bars The collection and distribution point for the power supplies: a "carry-all" Usually solid copper bars or rods, drilled for supply and feeder cables Very low impedance conductors Housed in junction boxes or distribution panels at central points Insulated from the structure and normally covered; braided copper strip for subsidiary barsAll loads on a bus bar are in parallel : each gets the full voltage junction box / distribution panel insulated from the structure on stand-offs feed from generator to circuit breakers solid copper bar, drilled for cable lugs protective cover Subsidiary bus bar: flexible braided copper strip Simplest form: a strip of linked terminals. Loads on a bus bar are all in PARALLEL.
Chapter 8 · Aircraft DC Power Systems
20
e-books by eatpl.in · © 2026 · Do not copy or distribute
The bus bar is where power is collected from the sources and distributed to the consumers. In its simplest form it is just a strip of linked terminals. In larger systems it is a thick, solid copper bar or rod, drilled so that the supply cables and the feeder cables to each circuit breaker can be bolted on. Being thick copper, it is a very low impedance conductor. Bus bars are mounted in junction boxes or distribution panels at central points in the aircraft, insulated from the structure on stand-offs, and normally given a protective cover. Flat, flexible strips of braided copper are also used as subsidiary bus bars. Every load connected to a bus bar is in parallel with the others, so each gets the full bus voltage, and switching a load off simply reduces the total current drawn from the bus.
Part 4 · A complete system
A typical light aircraft DC system BUS BAR battery master solenoid starter solenoid M starter motor starter switch BAT ALT split master switch ALT switch → field supply ext. power solenoid ext. power receptacle ALT alternator A ammeter radio interference capacitor voltage regulator overvoltage protector field 5 A ALT warn light 5 A cabin light 15 A avionics circuit breakers Battery through the master solenoid ; alternator through the ammeter ; field via the ALT switch , overvoltage protector and regulator .
Chapter 8 · Aircraft DC Power Systems
21
e-books by eatpl.in · © 2026 · Do not copy or distribute
Here is a whole single-alternator system, simplified. On the left, the battery is earthed on its negative side and connects through the master solenoid, a heavy-duty relay, to the bus bar. The battery half of the split master switch energises that solenoid. From the bus side of the master solenoid a heavy cable runs to the starter solenoid and the starter motor, worked by the starter switch, so the master must be on to start. An external power receptacle lets a ground power unit feed the bus through its own solenoid. On the right, the alternator output goes through the ammeter to the bus bar, with a small capacitor at the alternator to suppress radio interference. The alternator half of the master switch supplies the field, through the overvoltage protector and the voltage regulator. Finally, the bus bar feeds every consumer through its own circuit breaker, including the alternator warning light.
Part 4 · Priorities
Vital, essential and non-essential loads Design aims: loads keep their supply if a source fails (unless demand exceeds supply); a distribution fault has minimum effect and fire risk; a faulty consumer must not endanger others.
Vital Needed after an emergency wheels-up landing : emergency lighting, crash-switch fire extinguishers. Connected directly to the battery .
Essential Needed for safe flight in an in-flight emergency. Fed so they can always be supplied from a generator or the batteries .
Non-essential Can be isolated in an emergency for load shedding . Supplied from the generators only.
How it is achieved Paralleled generators, proper circuit protection , isolating failed generators , and buses fed from different sources .
Chapter 8 · Aircraft DC Power Systems
22
e-books by eatpl.in · © 2026 · Do not copy or distribute
A distribution system has three main aims. Loads should not lose their supply when a source fails, unless the total demand is more than the remaining sources can give. A fault in the distribution system itself, such as a short to earth at a bus bar, should have the minimum effect and the minimum fire risk. And a fault in one consumer must not endanger the supply to the others. These aims are met by paralleling generators, by proper circuit protection, by isolating failed generators, and by arranging bus bars so they can be fed from different sources. To do that, every consumer is put into one of three classes. Vital services are those needed after an emergency wheels-up landing, like emergency lighting and the crash-switch fire extinguishers; they are connected directly to the battery. Essential services keep the aircraft flying safely in an emergency. Non-essential services can be shed.
Part 4 · Split bus bar system
Split bus bars: who feeds whom G1 28 V G2 28 V gen. CB gen. CB No. 1 bus non-ess. DC · No. 2 inverter No. 2 bus non-ess. DC · No. 3 inverter Essential (centre) bus essential DC · No. 1 inverter (essential AC) Battery bus (hot bus) vital loads one-way feed battery switch 24 V batteries ext. power One generator fails : it is isolated and the other takes all the loads. Both fail : non-essential loads are lost; the batteries feed the essential bus (normally 30 minutes minimum).
Chapter 8 · Aircraft DC Power Systems
23
e-books by eatpl.in · © 2026 · Do not copy or distribute
This is the split bus bar system used on many twins, with twenty-eight-volt generators and twenty-four-volt batteries. Each generator feeds its own bus bar, number one or number two, which carries the non-essential loads. Both of these buses feed the essential bus in the centre, which carries the essential DC loads and the number one inverter for essential AC. The essential bus is linked through the battery switch to the battery bus, which is called the hot bus because it is always connected to the batteries, and which carries the vital loads. Watch what happens when number one generator fails. It is isolated automatically, and the other generator takes over all the loads through the essential bus. If the second generator fails too, the non-essential buses go dead, but the batteries now feed the essential bus, which keeps running for a pre-determined time, normally at least thirty minutes.
Part 4 · Worked example
How long will the batteries last? The battery (12 or 24 V, lead-acid or alkaline) starts the engines and is the emergency source After total generator failure it feeds the essential bus for a set time: normally 30 minutes minimum Endurance ≈ usable amp-hours ÷ load current Example: 40 Ah usable ÷ 70 A ≈ 34 minutes Inverter No. 1 (essential AC) is fed from the essential bus ; Nos. 2 and 3 from Nos. 1 and 2 buses 0 10 20 30 40 50 0 10 20 30 40 time after both generators fail (min) charge left (Ah) usable charge gone ≈ 34 min Batteries: 2 × 25 Ah in parallel = 50 Ah Usable (≈ 80 % charged): 40 Ah Essential load: 70 A Time = 40 Ah ÷ 70 A ≈ 0.57 h ≈ 34 minutes
Chapter 8 · Aircraft DC Power Systems
24
e-books by eatpl.in · © 2026 · Do not copy or distribute
The battery has two jobs: it starts the engines, and it is the emergency source when the generators fail. In the split system, the battery capacity is chosen so that it can carry the essential bus for a pre-determined time, normally at least thirty minutes, depending on the essential load and the battery state of charge. Let us check a design. Two twenty-five amp-hour batteries in parallel give fifty amp-hours. Assume about eighty per cent of that is really available, so forty amp-hours. The essential load is seventy amps. Forty divided by seventy is about zero point five seven hours, roughly thirty-four minutes, so this design just meets the thirty-minute aim. In reality capacity falls at high discharge rates, which is one more reason to shed load early. Notice also that the essential AC inverter is fed from the essential bus, while the non-essential inverters hang on the number one and number two buses.
Part 4 · Load shedding
Load shedding Reducing the electrical load when the sources cannot supply all of the demandAutomatic on some aircraft; on others the pilot monitors the ammeters Keep the total load within the rated output of the remaining generator Single-engine, alternator failed: switch off all but the essentials to save the battery Twin: two 100 A generators carrying 160 A; one fails → shed at least 60 A Alternator failed: 24 V, 35 Ah battery Radios and navigation 8 A keep Transponder 2 A keep Instrument lights 2 A keep Pitot heat 10 A OFF Landing light 9 A OFF Strobe and nav lights 5 A OFF Fuel boost pump 4 A OFF Before: 40 A → 28 Ah ÷ 40 A ≈ 42 min After: 12 A → 28 Ah ÷ 12 A ≈ 140 min (28 Ah = about 80 % of 35 Ah usable) Keep pitot heat ON if there is any risk of icing
Chapter 8 · Aircraft DC Power Systems
25
e-books by eatpl.in · © 2026 · Do not copy or distribute
Load shedding means reducing the total electrical load when the sources cannot supply everything being demanded. On some aircraft it happens automatically; on others the pilot watches the ammeters or load meters and keeps the total load within the rated output of whatever is still working. Take a twin with two generators each rated at one hundred amps, sharing a load of one hundred and sixty amps. If one fails, the survivor cannot carry one hundred and sixty, so at least sixty amps of non-essential load must go. In a single-engine aircraft an alternator failure leaves only the battery, so you decide what is truly essential for the flight at that moment and turn off everything else. In this example the load falls from forty amps to twelve, and the battery endurance rises from about forty-two minutes to about two hours and twenty minutes. Keep pitot heat on, though, if there is any chance of icing.
Part 4 · Generator failure
Generator failure: indications and actions Indications : warning light on; load meter at zero , or centre-zero ammeter showing discharge The cut-out opens (reverse current), isolating the generator from the bus Action 1 : switch off all unnecessary loads (load shedding )Action 2 : isolate the failed generator with its master (field) switch On a twin the engines keep running normally: ignition is independent −60 −30 0 +30 +60 AMPS A 0 10 20 30 40 50 60 LOAD A centre-zero: discharge load meter: zero ALT
Chapter 8 · Aircraft DC Power Systems
26
e-books by eatpl.in · © 2026 · Do not copy or distribute
How do you recognise a generator or alternator failure? The warning light comes on, and the ammeters agree: the load meter drops to zero, or the centre-zero ammeter swings into discharge as the battery takes over the loads. Behind the scenes, the reverse current cut-out will normally have opened already, isolating the failed generator from the bus bar. The actions are simple. First, switch off all unnecessary electrical loads, following the list in the aircraft handling notes; that is load shedding. Second, isolate the failed machine by switching its master or field switch off. That breaks the field circuit, so its output falls to zero or a small residual value and the failed system is made safe. On a twin you then continue on the remaining generator, with a reduced load. And remember: a generator failure does not stop the engine, because the ignition does not depend on the aircraft electrical system.
Summary
What to take into the exam Wiring Dipole = two wires (non-metal airframe). Earth return = structure is negative. Live wire to structure = short, fuse blows; open circuit = load stops.
Regulator and OVP Regulator varies field current: 14 V (12 V battery), 28 V (24 V battery). OVP trips at about 16.5 V in a 14 V system and opens the field.
Cut-out In series. Closed by rising voltage (≈ 26 V in 28 V system), opened by reverse current. None with alternators: diodes do it.
Differential cut-out Twins: stops circulating currents. Oncoming generator must be 2 % above the bus.
Meters Ammeter: low R, series, shunt in parallel. Voltmeter: high R, parallel, multiplier in series. Centre-zero = battery; load meter = generator.
Bus bars Copper, low impedance, loads in parallel. Hot bus = always on the battery. Vital → battery; essential → gen or battery; non-essential → gen.
Split bus One generator fails: isolated, the other takes the loads. Both fail: batteries feed essentials, normally 30 min minimum.
Failure drill Light on, load meter zero or discharge. Shed loads, switch the failed generator off (field). Engines keep running.
Chapter 8 · Aircraft DC Power Systems
27
e-books by eatpl.in · © 2026 · Do not copy or distribute
Let us pull it together. Dipole wiring uses two wires; earth return uses the structure as the negative, so a live wire touching the structure is a short and blows the fuse, while a broken wire just stops the load. The regulator controls field current to hold fourteen or twenty-eight volts, and the overvoltage unit trips the field at about sixteen and a half volts in a fourteen-volt system. The cut-out is in series, closes on rising voltage at about twenty-six volts in a twenty-eight-volt system, and opens on reverse current; alternators use diodes instead. On twins the differential cut-out waits for a two per cent margin. Ammeters are low resistance in series with shunts; voltmeters are high resistance in parallel with multipliers. The hot bus is always on the battery. In a generator failure, shed load and switch the failed generator off.