Electrics · Revision
Revision and Exam Practice The formulas, numbers and traps that electrics papers test again and again, with the DC specimen paper and a full set of revision questions.
r.m.s. = 0.707 × peak τ = C × R 28 V DC 115/200 V 400 Hz 1.2 V Ni-Cd 80 % 30 min 300 ÷ f 1.23 √H formulas · numbers · traps © 2026 eatpl.in. For the personal study of eatpl.in students only. Do not copy or distribute.
e-books by eatpl.in · © 2026 · Do not copy or distribute
Welcome to the revision chapter of the electrics course. Electrics papers reward two things: a handful of formulas used with the right units, and a clear picture of which way things go when something fails. Which way the cut-out moves, what a tripped breaker will do, what a nickel-cadmium battery tells you and what it hides. In this chapter we walk through the whole syllabus, one block per page: the DC basics and protection, batteries and DC machines, DC power systems and bonding, then AC theory, generation, paralleling, transformers and motors, and finally the electronics and radio chapters. On every page look for the formula or number to remember, and the trap. After that come the worked calculations, the classic traps, the quiz, the question bank and the DC specimen paper.
How to use this chapter
The whole electrics syllabus, one page per block Each page gathers one block of the syllabus: the formulas, the numbers and the classic traps. Every revision question links back to one of them.
DC basics and protection Ohm’s law and power, switches and relays, fuses, breakers and capacitors.
Batteries and DC machines Lead-acid and Ni-Cd, magnetism, DC generators and motors.
DC systems and bonding Bus bars, cut-outs, load shedding, generator failure, bonding and screening.
AC theory and generation Sine wave, r.m.s., reactance, power factor, alternators, CSD and IDG.
AC systems and machines Paralleling and load sharing, split and parallel buses, transformers, TRUs and AC motors.
Electronics and radio Computers, semiconductors, logic gates, radio waves and propagation. Then calculations, traps and questions.
Chapter 21 · Revision and Exam Practice
2
e-books by eatpl.in · © 2026 · Do not copy or distribute
This revision chapter squeezes the whole electrics syllabus onto about twenty pages, in six blocks. First the DC basics: Ohm’s law and power, switches and relays, then fuses, breakers and capacitors. Second, batteries and the DC machines, with the magnetism behind them. Third, the DC power system and bonding. Fourth, AC theory and AC generation, with the constant speed drive. Fifth, the AC system as a whole: paralleling, load sharing, bus layouts, transformers and AC motors. And sixth, the electronics and radio chapters. On every page look for three things: the formula or number to remember, the rule, and the trap the examiner likes to set. After the last block comes a page of worked calculations, a page of traps and a method. Then the quiz, the question bank and the DC specimen paper, each question linked back to the page that answers it.
DC basics
Ohm’s law, power, series and parallel V = I × R : double the voltage, double the current; double the resistance, half the currentPower P = V × I = I² R = V² ÷ R : double the current, four times the heat Series: R adds, same current · parallel: reciprocals add, same voltage, R total below the smallest R rises with length, falls with area: double the diameter, a quarter of the resistance Conventional current + to − , electrons − to + · EMF in volts , mega = 10⁶ Ammeter in series , low R · voltmeter in parallel , high R · ohmmeter on a dead circuit Ohm’s law on a 28 V supply: I = V ÷ R 0 7 14 21 28 0 2 4 6 8 Voltage (V) Current (A) 4 Ω → 7 A 7 Ω → 4 A 14 Ω → 2 A lower R, steeper line Series and parallel: the worked network 28 V 4.6 Ω 12 Ω 12 Ω 4 Ω 7 Ω 9.2 V 14 V 4.8 V across the group Group: 1 ÷ (1/12 + 1/12 + 1/4) = 2.4 Ω · total 4.6 + 2.4 + 7 = 14 Ω I = 28 ÷ 14 = 2 A · P = V × I = 56 W · drops 9.2 + 4.8 + 14 = 28 V
Chapter 21 · Revision and Exam Practice
3
e-books by eatpl.in · © 2026 · Do not copy or distribute
Everything in electrics rests on Ohm’s law: voltage equals current times resistance. So at a fixed resistance, double the voltage and the current doubles; double the resistance and it halves. The graph shows three resistors on a twenty-eight volt supply: the lower the resistance, the steeper the line. Power has three forms: volts times amps, current squared times resistance, and voltage squared over resistance. Four amps through five ohms is eighty watts, and because heat goes with current squared, double the current means four times the heat. In series the resistances add; in parallel the reciprocals add, so the total is always below the smallest branch. The network below shows both: four point six ohms, plus two point four for the parallel group, plus seven, gives fourteen ohms, and twenty-eight volts drives two amps. Remember too: conventional current flows positive to negative, and a megohm is a million ohms.
Switches, relays and solenoids
Which switch does what, and the trap Device How it works Remember Relay Fixed core attracts a hinged armature Small current switches a large one · heavy duty: contactor Solenoid Moving core (plunger) pulled into the coilStarter solenoid; valves and locks NO and NC Describe the contacts at rest , de-energised Energise the coil: NO closes, NC opens Micro switch Tiny make–break movement, snap action Position: doors, gear, flaps Bimetallic switch Two metals expand differently: the strip bends Overheat and fire warning, thermal breakers Proximity sensors Inductive , capacitive or magnetic : no contactGear (iron target) · liquid levels · N1, N2, wheel speed Time, centrifugal Act after a set time, or at a set rpm APU door shuts 30 s after shutdown · starter cut-out Inertia switch A mass moves under crash deceleration Operates automatically in a crash : no pilot selection
Chapter 21 · Revision and Exam Practice
4
e-books by eatpl.in · © 2026 · Do not copy or distribute
The switches chapter is mostly definitions, so learn them as pairs. A relay has a fixed core that attracts a hinged armature; a solenoid has a moving core, a plunger, pulled into the coil. Both let a small current from the flight deck switch a large current at the load, and the coil is insulated from the contacts. A heavy-duty relay is called a contactor. Normally open and normally closed describe the contacts at rest, with the coil de-energised: energise it and the normally open contacts close. Micro switches sense position with a tiny snap movement. Bimetallic switches bend with heat, for overheat and fire warning. Proximity sensors come in three kinds: inductive needs an iron target, capacitive senses any material including liquids, and magnetic sensors count passing teeth to measure speed. Time switches act after a delay, centrifugal switches at a set rpm. And the inertia, or crash, switch operates automatically when the aircraft decelerates violently in a crash.
Circuit protection and capacitors
Fuses, breakers and the time constant Fuse in series , rated in amps for the circuit’s load (power) , below the cable limit Blown fuse: switch off, replace once only with the correct rating ; never uprate Spares carried by law : 10 % of each rating, at least 3 Breaker = fuse + switch, white band when tripped; trip-free : cannot be held in while the fault remains Current limiter: high melting point, rides through a big overload: TRU outputs Capacitor blocks DC, appears to pass AC · τ = C × R : 63.2 % at 1τ, full at 5τ Capacitor charge and discharge (τ = C × R) 0 1 2 3 4 5 0 25 50 75 100 Time (in time constants τ) Per cent of supply voltage 63.2 % after 1τ discharge: 36.8 % left 99.3 %: full at 5τ 100 µF × 10 kΩ = 1 s Spare fuses: 10 % of each rating, at least 3 Fitted 10 % Carry 12 of one rating 1.2 3 45 of one rating 4.5 5 80 of one rating 8 8 Fuse: opens before full fault current Breaker: after it, and can be reset
Chapter 21 · Revision and Exam Practice
5
e-books by eatpl.in · © 2026 · Do not copy or distribute
A fuse is a deliberate weak link in series with the load. Its rating is chosen from what the circuit draws: seventy-two watts at twenty-four volts is three amps, so a five amp fuse. If it blows, switch off and replace it once only with the correct rating; if it blows again, there is a defect to find. Never fit a bigger one. Spare fuses are a legal requirement: ten per cent of each rating, with at least three. A circuit breaker is a fuse and a switch in one; a trip-free breaker cannot be held closed while the fault is still there, so it will not reset until the circuit is back to normal. Current limiters ride through large overloads and protect heavy feeders such as TRU outputs. Finally the capacitor: it blocks DC once charged and appears to pass AC. The time constant is capacitance times resistance: sixty-three point two per cent charged after one time constant, and fully charged after five.
Batteries
Lead-acid, Ni-Cd and the numbers Lead-acid: 2.2 V off load, 2.0 V nominal, 1.8 V flat · SG 1.27 → 1.17 · 12 cells for 24 V Ni-Cd: potassium hydroxide, 1.2 V , flat curve; SG and voltage show nothing : capacity test only Series: volts add , Ah the same · parallel: volts the same, Ah add Ah = A × h: 60 Ah at the 10-hour rate = 6 A for 10 h Check with a voltmeter on load · capacity test every 3 months, at least 80 % Ni-Cd hot after engine start, charge current rising: thermal runaway Cell voltage at a steady discharge (typical shapes) 0 25 50 75 100 1.0 1.2 1.4 1.6 1.8 2.0 2.2 Capacity used (%) Cell voltage (V) lead-acid: falls steadily, 2.0 V nominal Ni-Cd: flat near 1.2 V, then a sudden drop 1.8 V: flat Combining and testing 2 × 12 V 40 Ah in series 24 V, 40 Ah (volts add) 2 × 12 V 40 Ah in parallel 12 V, 80 Ah (Ah add) 60 Ah at the 10-hour rate 60 ÷ 10 = 6 A for 10 h Capacity test: 60 Ah at 60 A lasts 42 min 42 ÷ 60 = 70 % < 80 %: reject 40 Ah usable feeding a 70 A essential load 40 ÷ 70 × 60 ≈ 34 min
Chapter 21 · Revision and Exam Practice
6
e-books by eatpl.in · © 2026 · Do not copy or distribute
Batteries give the exam a lot of numbers. A lead-acid cell gives two point two volts off load, two volts nominal and one point eight when flat, and its specific gravity falls from one point two seven to one point one seven as it discharges. Twelve cells make a twenty-four volt battery. The nickel-cadmium cell gives about one point two volts and holds it almost to the end, as the graph shows; its electrolyte takes no part in the reaction, so neither the hydrometer nor the voltage tells you the state of charge. Only a measured discharge does. In series the volts add and the capacity stays the same; in parallel the reverse. Capacity is amps times hours, so sixty ampere hours at the ten-hour rate is six amps for ten hours. Always check a battery voltage on load, because even a weak battery shows full voltage off load. And a Ni-Cd that runs hot after a start, with charge current rising, may be going into thermal runaway.
Magnetism and electromagnetism
The rules behind every machine Topic Rule to remember Flux lines Out of N , into S outside the magnet; closed loops that never cross · like poles repel, unlike attract Materials Soft iron : high permeability, low retentivity: relay, transformer cores · hard steel : keeps it: permanent magnetsQuantities Flux Φ in webers · flux density B = Φ ÷ area, in tesla · MMF in ampere-turns · μ = B ÷ H Current in a wire Concentric circles; corkscrew rule ; ⊗ into the page gives clockwise flux Solenoid Right hand grasp: fingers with the current, thumb = N · stronger with more turns, more current, iron core, until saturation Motor effect F = B × I × L · Fleming’s LEFT hand: First finger Field, seCond Current, thuMb Motion Induction Fleming’s RIGHT hand for generators · EMF ∝ rate of change of flux (Faraday) · Lenz: it opposes the change Earth’s field The pole in the far north is magnetically a south-type pole: it attracts the compass N end
Left hand: motors (force from current). Right hand: generators (current from motion). Same fingers: Field, Current, Motion.
Chapter 21 · Revision and Exam Practice
7
e-books by eatpl.in · © 2026 · Do not copy or distribute
Magnetism is a page of rules, and the generators and motors that follow depend on them. Flux lines leave the north pole and enter the south pole outside the magnet, and they never cross. Soft iron is easy to magnetise and loses it again, so it makes relay and transformer cores; hard steel keeps its magnetism, so it makes permanent magnets. Flux density is flux per square metre, in tesla, and the push that drives flux is measured in ampere-turns. A current in a wire makes circular flux, and the corkscrew rule gives its direction. For a coil, grasp it with the right hand, fingers along the current, and the thumb points to the north pole. Now the pair you must not mix up: Fleming’s left hand rule is for motors, the right hand rule is for generators, with the same fingers: first finger field, second finger current, thumb motion. And Lenz’s law: an induced EMF always opposes the change that causes it.
DC generators
Windings, regulation and the cut-out Commutator turns the loop’s AC into DC; more coils, less ripple Shunt-wound output falls gradually with load; series rises; compound almost constant Regulator: a variable resistance in the field holds 28 V whatever the rpm and load Cut-out closes as generator voltage rises ; opens on reverse current Paralleled voltages must be the same ; a difference drives a circulating current DC alternator: rotating field, diodes, needs no cut-out ; full output at low rpm Terminal voltage as load is applied 0 25 50 75 100 0 8 16 24 32 Load current (% of rated) Terminal voltage (V) compound: almost constant shunt: falls gradually series: rises, then falls Two generators in parallel on a 28.0 V bus 100 A 28.5 V 100 A 28.5 V 120 A 28.6 V 80 A 28.4 V 160 A 28.8 V 40 A 28.2 V Each 0.1 V of difference moves about 20 A: voltages must be equal
Chapter 21 · Revision and Exam Practice
8
e-books by eatpl.in · © 2026 · Do not copy or distribute
A generator loop makes alternating current; the commutator reverses the connections every half turn so the brushes collect DC. The field windings decide how the output behaves under load, and the top graph shows the three types. A series generator’s voltage rises with load, so it is never used for aircraft supplies. A shunt-wound generator’s output falls gradually as load is applied, and a compound machine holds almost constant. The voltage regulator inserts a variable resistance in the field circuit, so the output stays at twenty-eight volts whatever the engine speed and the load. The reverse current cut-out closes when the generator voltage rises above the battery, and opens when current flows back from the battery. When two generators run in parallel their voltages must be the same: the lower chart shows that every tenth of a volt of difference moves about twenty amps from one machine to the other. A DC alternator uses diodes, so it needs no cut-out.
DC motors and actuators
Back EMF, motor types and actuators Back EMF ∝ speed, opposes the supply: as the motor speeds up, back EMF rises , current falls Armature current = (supply − back EMF) ÷ R: huge at start , so a starting resistor Series motor: highest starting torque, overspeeds off load : starters, actuatorsShunt motor: nearly constant speed: fans, pumpsReverse armature or field , never both · split-field series motors in actuators Starter-generator: compound machine, motor to start, generator to run Back EMF and armature current (28 V, 0.2 Ω) 0 4 8 12 16 20 24 28 0 50 100 150 Back EMF (V), rising with speed Armature current (A) standstill: 140 A heavy load: 40 A normal: 10 A I = (28 − Eb ) ÷ 0.2 Speed against load torque 0 0.4 0.8 1.2 1.6 0 1 2 Load torque (× rated) Speed (× rated) series: races away off load shunt: nearly constant
Chapter 21 · Revision and Exam Practice
9
e-books by eatpl.in · © 2026 · Do not copy or distribute
A motor is a generator run backwards, and as its armature turns it generates its own EMF, the back EMF, which opposes the supply. Back EMF is proportional to speed, so as the motor speeds up the back EMF increases and the current falls. The top graph uses a twenty-eight volt supply and a nought point two ohm armature. At standstill there is no back EMF, so the current would be one hundred and forty amps: that is why starters have a starting resistor or a slow-start circuit. At twenty-six volts of back EMF only two volts are left to drive current, so ten amps flow. The lower graph shows the two classic motors. The series motor gives the greatest starting torque but runs away with no load, so it drives starters and actuators through a gearbox. The shunt motor holds an almost constant speed. To reverse a DC motor, reverse the armature or the field, never both.
Aircraft DC power systems
Bus bars, load shedding and generator failure Earth return: negative to the structure · dipole: two wires, a bridged pair blows the fuse Hot battery bus: vital loads · essential: generator or battery · non-essential: shed first Load shedding = reducing the total load to what the sources can supplyDifferential cut-out closes when the generator is above the battery bus , about 2 % Generator ammeter shows its load ; failed: warning light on , ammeter zero or discharge On a twin the engines run normally ; batteries feed essentials for about 30 min A twin-generator DC system GEN 1 cut-out GEN 2 cut-out No. 1 bus (non-essential first) No. 2 bus tie Essential bus: generator or battery BATT hot battery bus: vital Diodes stop one side feeding a fault on the other Generator failure drill • Warning light on; ammeter zero or discharge; the cut-out opens • Shed load to what is left; switch off the failed generator’s field • Both failed: battery feeds essentials, e.g. 40 Ah ÷ 70 A ≈ 34 min • Engines keep running: ignition does not need the generators
Chapter 21 · Revision and Exam Practice
10
e-books by eatpl.in · © 2026 · Do not copy or distribute
In an earth return system the negative pole of the supply is joined to the airframe, so each load needs only one wire; a live wire touching structure is a short circuit and the fuse blows. In a two-wire, or dipole, system the same happens if the two conductors are bridged. Loads are sorted by how badly you need them. Vital loads sit on the hot battery bus, always connected. Essential loads can be fed by a generator or the battery. Non-essential loads are the first to go when you shed load, which simply means reducing the total load to what the remaining sources can carry. On twins, a differential cut-out connects a generator only when its voltage is a little above the battery bus bar, so no circulating current flows. Each generator’s ammeter shows the load it is carrying. When a generator fails, its warning light comes on and its ammeter reads zero or discharge. Shed load and switch off its field. The engines keep running, and the battery gives about thirty minutes of essential power.
Bonding and screening
Same potential everywhere, and no radio noise Item Purpose, place or number Static charge Picked up from precipitation, dust and cloud; a potential difference between parts means sparks, fire risk and radio noise Bonding All parts at the same potential ; a low-resistance earth return ; safe path for static and lightning Primary / secondary Primary joins major structure with heavy straps · secondary joins equipment, pipes and panels Poor bonding shows as Static noise on the radios , arcing, faulty earth returnsStatic wicks Trailing edges and tips; brush discharge to minimise radio interference Conductive tyres High carbon content: discharge the static at touchdown Refuelling Bowser and aircraft bonded and earthed; nozzle bonded to the tank before the cap is opened Screening Stops equipment interfering with the radios : suppressors and metal sheaths; slip rings over 200 rpm , switching over 10 Hz
Bonding = same potential and a safe current path. Screening = keeping electrical noise out of the radios. Do not swap the two words.
Chapter 21 · Revision and Exam Practice
11
e-books by eatpl.in · © 2026 · Do not copy or distribute
Bonding and screening are often confused, so keep their jobs apart. An aircraft picks up static charge from rain, snow, dust and cloud, and any potential difference between parts can give a spark, a fire risk and noise in the radios. Bonding joins every part with low-resistance strips, so the whole aircraft is at the same potential. It also gives a low-resistance path for earth return circuits and a safe path for static and lightning. Primary bonding joins the major structure with heavy straps; secondary bonding joins equipment and pipes. Poor bonding usually shows up as static noise on the radios. Static wicks on the trailing edges discharge the charge gently, to minimise radio interference, and conductive tyres discharge it at touchdown. When refuelling, bond the bowser and the aircraft first. Screening is different: it surrounds noisy equipment, such as ignition systems, commutator machines and fast-switching circuits, so that it does not interfere with the radio equipment.
Introduction to AC
Frequency, r.m.s., phase and power factor f = poles × rpm ÷ 120 : 8 poles at 6000 rpm = 400 Hz · T = 1 ÷ f = 2.5 msr.m.s. = 0.707 × peak : 115 V r.m.s. peaks at 162.6 V; meters read r.m.s. CIVIL: in a C , I leads V; V leads I in an L · resistance: in phase XL = 2πfL rises with f · XC = 1 ÷ 2πfC falls · Z = √(R² + X²) p.f. = kW ÷ kVA = cos φ: 1 for resistance, 0 for pure L or C; alternators rated in kVA Star: VL = 1.73 VP (115/200 V ), IL = IP · delta: VL = VP 115 V r.m.s. at 400 Hz 0 1.25 2.5 3.75 -162.6 0 115 162.6 Time (ms) Volts r.m.s. 115 V = 0.707 × peak peak 162.6 V T = 1 ÷ 400 = 2.5 ms In an inductor (L) current lags by 90° V I C I leads V L V leads I R in phase 72 kW true 54 kVAR 90 kVA apparent p.f. = kW ÷ kVA = 72 ÷ 90 = 0.8 = cos 36.9° Resistive load: p.f. 1 Pure L or C: p.f. 0
Chapter 21 · Revision and Exam Practice
12
e-books by eatpl.in · © 2026 · Do not copy or distribute
The AC block starts with frequency: poles times rpm over one hundred and twenty. Eight poles at six thousand rpm give four hundred hertz, and one cycle then lasts two and a half milliseconds. AC values are quoted as r.m.s., nought point seven oh seven times the peak. So a hundred and fifteen volt supply actually peaks at about a hundred and sixty-three volts. Phase is remembered with the word CIVIL: in a capacitor current leads voltage; voltage leads current in an inductor. Inductive reactance rises with frequency, capacitive reactance falls, and impedance is their vector sum with resistance. Power comes in three kinds, shown in the triangle: true power in kilowatts, reactive power in kilovars, and apparent power in kilovolt-amps. The power factor is true over apparent: ninety k V A at a power factor of nought point eight is seventy-two kilowatts. In a star connection, line voltage is one point seven three times phase voltage: one hundred and fifteen becomes two hundred.
Alternators, CSD and IDG
Brushless generation at a constant 400 Hz Rotating field , stationary armature (stator) output: no heavy current through slip rings Brushless: PMG → GCU → exciter → rotating rectifier → main field → stator Speed sets frequency ; field current sets voltage (the regulator) CSD: hydraulic pump and motor, governor and swash plate: 400 Hz , limits about 380–420 Hz IDG = CSD + generator, own oil · disconnect for low oil pressure or high temperature Reconnect only on the ground , engine stopped · VSCF: no CSD, electronics make 400 Hz The brushless generator chain PMG on the shaft GCU regulator Exciter field stator, DC Exciter armature rotor, AC Rotating rectifier AC → DC Main field rotor, DC Main stator 115/200 V out Speed sets frequency · field current sets voltage Output frequency against engine speed 50 60 70 80 90 100 150 200 250 300 350 400 450 Engine speed (% of the speed giving 400 Hz direct) Frequency (Hz) CSD / IDG: 400 Hz (380–420) direct drive: frequency wild, f ∝ rpm 60 %: 240 Hz
Chapter 21 · Revision and Exam Practice
13
e-books by eatpl.in · © 2026 · Do not copy or distribute
Aircraft alternators turn the field and take the output from the stationary stator, so only the small field current needs any sliding contact, and in the brushless machine none at all. Follow the chain in the top diagram: a permanent magnet generator powers the generator control unit, which feeds the exciter field; the exciter armature on the shaft makes AC, the rotating rectifier turns it into DC for the main field, and the main stator delivers one hundred and fifteen over two hundred volts. Remember: speed sets the frequency, field current sets the voltage. Driven straight from the engine, the frequency would follow engine speed, the red line below. The constant speed drive, a hydraulic pump and motor controlled by a governor, holds the generator at the speed that gives four hundred hertz. An IDG combines drive and generator with its own oil. For low oil pressure or high oil temperature the crew disconnect it, and it can only be reconnected on the ground with the engine stopped.
Paralleling and load sharing
Matching, sharing and protecting AC generators Topic Rule to remember Before paralleling Same voltage , same frequency , in phase , same phase sequence ; load sharing available · dark lamps = close A mismatch Drives a circulating current , limited only by the tiny internal impedance: 20° error ≈ 400 A Real load (kW) Shared by drive torque : the load controller trims each CSD governor (speed, frequency) Reactive load (kVAR) Shared by excitation : the voltage regulator changes exciter field current Frequency wild Never paralleled: frequencies never match · fine for heaters and de-icing The breakers GCB : generator to its load bus · BTB : bus to sync bus · GCR : in the field circuitProtection Over/under voltage and frequency, over-current, differential (generator end vs bus end current) Discrimination Generator fault: its GCB opens · load-bus fault: BTB first, then GCB
Real ↔ torque ↔ CSD. Reactive ↔ excitation ↔ voltage regulator. Load sharing loops work only while the BTBs are closed.
Chapter 21 · Revision and Exam Practice
14
e-books by eatpl.in · © 2026 · Do not copy or distribute
Before two AC generators can be connected together, four things must match: voltage, frequency, phase, and phase sequence, and a working load sharing system must be available. Any mismatch drives a circulating current from one machine into the other, limited only by their very low internal impedance. Once in parallel, the generators share two kinds of load, and this is the favourite question. Real load, in kilowatts, is shared by adjusting the drive torque: the load controller trims each constant speed drive. Reactive load, in kilovars, is shared by adjusting the excitation through each voltage regulator. Frequency-wild generators can never be paralleled. Learn the three breakers: the generator circuit breaker connects a generator to its load bus, the bus tie breaker joins that bus to the synchronising bus, and the generator control relay sits in the field circuit. Differential protection compares the current at the two ends of a feeder. And for a fault on a load bus, the bus tie opens first, then the generator breaker.
Practical AC systems
Split bus or parallel bus? Split bus (modern twins): each generator feeds its own bus ; BTB normally open One generator fails: its GCB opens, the BTB closes , the other feeds both; galleys shed Two sources are never paralleled ; APU or ground power only with the GCBs open Both fail: AC essential from the static inverter , DC from the battery, about 30 min Parallel bus (three or four engines): BTBs closed , sync buses joined by the SSB TRUs make the 28 V DC; RAT emergency generator on many types Split bus: normal operation GEN 1 GCB GEN 2 GCB AC BUS 1 AC BUS 2 BTB BTB normally open APU / EXT TRU 1 DC BUS 1 (28 V) TRU 2 DC BUS 2 (28 V) Battery bus Static inverter AC ESS (from bus 1) DC → AC when both gens fail Normal each GEN its own bus · BTBs open One GEN fails its GCB opens · BTBs close · shed galleys Both fail battery + static inverter: essentials, ~30 min
Chapter 21 · Revision and Exam Practice
15
e-books by eatpl.in · © 2026 · Do not copy or distribute
Most modern twin jets use a split bus system, shown in the diagram. Each generator feeds its own AC bus through its generator circuit breaker, and the bus tie breakers are normally open, so the two generators are never connected together. Each AC bus feeds a transformer rectifier unit for the DC side. If one generator fails, its breaker opens and the bus tie closes automatically, so the remaining generator feeds both buses; the galleys are shed to keep the load within its rating. On the ground the APU generator or external power feeds the buses, but only when the engine generators are off line. If both generators fail, the static inverter makes AC for the essential bus from the battery, which lasts about thirty minutes, and many types deploy a ram air turbine. Three- and four-engine aircraft often run their generators in parallel instead, with the bus ties closed and a split system breaker joining the two synchronising buses.
Transformers, rectifiers and TRUs
Turns ratio, rectifiers and converters E₂ ÷ E₁ = N₂ ÷ N₁ ; current goes the other way; power in = power out Step-up: more secondary turns, more volts, less current · AC only, by mutual induction Open secondary: primary takes only a tiny magnetising current Auto-transformer: one tapped winding, less copper, no isolation : 26 V AC instruments Diode bridge (4 diodes) full-wave; 3-phase bridge (6 diodes) : nearly steady DC TRU : 115/200 V 400 Hz 3-phase AC → 28 V DC · inverter : DC → ACStep-down transformer: 115 V to 26 V N1 = 1150 E1 = 115 V I1 = 1.81 A N2 = 260 E2 = 26 V I2 = 8 A E2 ÷ E1 = N2 ÷ N1 · I2 ÷ I1 = N1 ÷ N2 · power in = power out (208 VA) Rectifier outputs AC in Half-wave (1 diode) Bridge (4 diodes) 3-phase bridge (6 diodes)
Chapter 21 · Revision and Exam Practice
16
e-books by eatpl.in · © 2026 · Do not copy or distribute
A transformer changes AC voltage by mutual induction between two windings on a laminated core, and it only works on AC. The voltage ratio equals the turns ratio, secondary over primary. The example in the diagram steps one hundred and fifteen volts down to twenty-six with eleven hundred and fifty primary turns and two hundred and sixty secondary turns. Power in equals power out, so current changes the opposite way: step the voltage down and the current goes up. With the secondary open, the primary takes only a tiny magnetising current. An auto-transformer uses one tapped winding: lighter, but with no isolation between input and output. Rectifiers do the opposite of an inverter: they turn AC into DC. The lower strips show the outputs: half-wave, the full-wave bridge, and the three-phase bridge, which gives almost steady DC. Put a transformer and a three-phase rectifier together and you have the TRU, which makes the twenty-eight volt DC supply of every AC aircraft.
AC motors
Synchronous speed, slip and the two motor families Three-phase stator makes a rotating field ; the rotor follows it NS = 120 f ÷ p : 4 poles at 400 Hz = 12 000 rpm ; set by frequency, not voltageSynchronous: AC stator, DC rotor via slip rings, exactly NS , not self-starting Induction: cage rotor, no brushes , runs about 5 % slow (slip) Swap two phases: it reverses · lose one phase: about half speed, will not restart Single-phase: needs a split-phase start (resistance, inductance or capacitor) Induction motor torque against speed (4 poles, 400 Hz) 0 3000 6000 9000 12000 0.0 0.5 1.0 Rotor speed (rpm) Torque (× maximum) NS = 120 × 400 ÷ 4 = 12000 runs here: 5 % slip, 11400 rpm starting torque no torque at NS : no slip, no induced current Synchronous speed = 120 f ÷ p Poles 2 24000 3000 4 12000 1500 6 8000 1000 8 6000 750 rpm at 400 Hz rpm at 50 Hz Synchronous motor: exactly NS · induction: a few per cent below
Chapter 21 · Revision and Exam Practice
17
e-books by eatpl.in · © 2026 · Do not copy or distribute
Feed three-phase current to three stator windings a hundred and twenty degrees apart and you get a magnetic field of constant strength that rotates. Its speed, the synchronous speed, is one hundred and twenty times the frequency divided by the number of poles: a four-pole motor on four hundred hertz gives twelve thousand rpm. It depends on frequency, not on voltage. The synchronous motor has a DC-fed rotor that locks onto the field and turns at exactly synchronous speed, but it cannot start by itself. The induction motor has a squirrel cage rotor with no brushes and no supply; current is induced in it only because it turns slower than the field. That difference is the slip, about five per cent, so our motor runs at about eleven thousand four hundred rpm, as the torque curve shows. Swap any two supply leads and an induction motor reverses. Lose one phase and it runs on at about half speed but will not restart.
Basic computers
Number bases, hardware and memory Topic Rule to remember Number bases Binary 2 · octal 8 (3 bits a digit) · decimal 10 · hexadecimal 16, digits 0–9 and A–F (4 bits a digit) Binary columns 1, 2, 4, 8, 16, 32, 64, 128: 111011 = 32 + 16 + 8 + 2 + 1 = 59 · 8 bits count up to 255 Bit and byte A bit is the smallest element; a byte is 8 bits Hardware Input, CPU, memory, output · CPU = ALU, registers and control unit, timed by the clockVolatile memory RAM : written and read at will, lost when the power goes offNon-volatile memory ROM, PROM, EPROM (erased by ultraviolet), EEPROM , EAROM (FMS database) Input or output? Keyboard, mouse: input · screen, printer: output · disks: storage Conversion A to D between analogue sensors and the computer · D to A to analogue devices
Decimal to binary: divide by 2 and read the remainders upwards. Every odd number ends in 1.
Chapter 21 · Revision and Exam Practice
18
e-books by eatpl.in · © 2026 · Do not copy or distribute
The computers chapter rewards careful arithmetic and clear definitions. Know the bases: binary is base two, octal eight, decimal ten and hexadecimal sixteen, using the letters A to F for ten to fifteen. Binary columns double from the right: one, two, four, eight and so on, so one one one oh one one is thirty-two plus sixteen plus eight plus two plus one, fifty-nine. A bit is a single binary digit, and a byte is eight bits. A basic computer has four parts: input, the central processing unit, memory and output. Inside the processor are the arithmetic and logic unit, the registers and the control unit, all kept in step by the clock. Random access memory is volatile: switch off and its contents are lost. The read-only family is not: ROM, programmable ROM, EPROM erased by ultraviolet light, and the electrically erasable types used for databases such as the FMS. And analogue sensors need an analogue to digital converter before the computer can read them.
Semiconductors
Doping, the junction and the transistor Silicon and germanium: 4 valence electrons; resistance falls as temperature rises N-type: donor , 5 valence (P, As, Sb), majority electrons · P-type: acceptor, 3 valence, majority holes Both N and P material are electrically neutral Forward bias: P to + ; conducts after about 0.6–0.7 V (Si), 0.2–0.3 V (Ge) Reverse bias: depletion layer widens, only µA leakage · zener works in breakdown Transistor: small base current controls large collector current · IE = IB + IC Diode forward characteristic 0 0.2 0.4 0.6 0.8 1 0 25 50 75 100 Forward voltage (V) Current (mA) Ge Si knee: Si 0.6–0.7 V Ge 0.2–0.3 V reverse bias: only µA leakage Forward bias: P to positive P-type: holes (acceptor, 3) N-type: electrons (donor, 5) depletion + − Both are neutral overall · IE = IB + IC in a transistor
Chapter 21 · Revision and Exam Practice
19
e-books by eatpl.in · © 2026 · Do not copy or distribute
Semiconductors start with silicon and germanium, with four electrons in the outer shell. Unlike metals, their resistance falls as they warm up, because heat frees more carriers. Doping makes them useful. Add an element with five valence electrons, such as phosphorus or arsenic, and you get N-type material whose majority carriers are electrons; add one with three, such as boron, and you get P-type with holes as majority carriers. The classic trap: both materials are still electrically neutral overall. Where P meets N a depletion layer forms. Connect the P side to the positive terminal and the junction is forward biased: once the barrier is overcome, about nought point six to nought point seven volts for silicon, current rises steeply, as the curve shows. Reverse bias widens the depletion layer and only a tiny leakage flows. In a transistor a small base current controls a much larger collector current, and the emitter current is the sum of the two.
Logic gates
All the two-input gates in one truth table A B AND OR NAND NOR XOR XNOR 0 0 0 0 1 1 0 1 0 1 0 1 1 0 1 0 1 0 0 1 1 0 1 0 1 1 1 1 0 0 0 1 Rule all 1 any 1 not all 1 none 1 differ same
NOT: one input, inverted. Bubble = invert: AND + bubble = NAND, OR + bubble = NOR. Logic 1 = on, true, high, closed switch. Every gate has one output.
Chapter 21 · Revision and Exam Practice
20
e-books by eatpl.in · © 2026 · Do not copy or distribute
All the logic gates fit in one truth table, so learn this page as a picture. AND gives a one only when all its inputs are one, like switches in series. OR gives a one when any input is one, like switches in parallel, and that includes the case when both are one. NAND and NOR are simply AND and OR followed by an inverter, shown on the symbol by a small bubble: so NAND gives a nought only when all inputs are one, and NOR gives a one only when all inputs are nought. Exclusive OR gives a one when the two inputs differ, and exclusive NOR when they are the same. The NOT gate has a single input and inverts it. Remember too that logic one means on, true, high, or a closed switch, and that in positive logic the one is the more positive voltage. However many inputs a gate has, it always has exactly one output.
Properties of radio waves
Speed, wavelength and the frequency bands c = 3 × 10⁸ m/s ≈ 162 000 nm per second · E and H fields at 90° Polarisation = the plane of the electric field, set by the aerial λ (m) = 300 ÷ f (MHz) : 121.5 MHz → 2.47 m · 375 kHz → 800 mBands go up in tens from 3 : VLF 3–30 kHz … HF 3–30 MHz, VHF 30–300 MHz, UHF, SHF NDB LF/MF · long-range voice HF · voice, VOR, ILS localiser VHF · DME, glidepath, SSR UHF · radio altimeter, weather radar SHF Phase difference needs the same frequency : 360° per cycle and per wavelength λ (m) = 300 ÷ f (MHz): the bands VLF LF MF HF VHF UHF SHF EHF 3 kHz 3 MHz 3 GHz 300 GHz 375 kHz 121.5 MHz Band Frequency Wavelength Uses VLF 3–30 kHz 100–10 km — LF 30–300 kHz 10–1 km NDB MF 300–3000 kHz 1000–100 m NDB, comms HF 3–30 MHz 100–10 m long-range voice VHF 30–300 MHz 10–1 m voice, VOR, LOC UHF 300–3000 MHz 100–10 cm GP, DME, SSR, GNSS SHF 3–30 GHz 10–1 cm rad alt, wx radar EHF 30–300 GHz 10–1 mm — 121.5 MHz: 300 ÷ 121.5 = 2.47 m (VHF) 375 kHz = 0.375 MHz: 300 ÷ 0.375 = 800 m (MF) 3.2 cm = 0.032 m: 300 ÷ 0.032 = 9375 MHz (SHF)
Chapter 21 · Revision and Exam Practice
21
e-books by eatpl.in · © 2026 · Do not copy or distribute
Radio waves travel at the speed of light, three hundred million metres per second, about a hundred and sixty-two thousand nautical miles per second. The electric and magnetic fields are at right angles to each other and to the direction of travel, and the polarisation is the plane of the electric field, set by the aerial. The working formula is wavelength in metres equals three hundred divided by frequency in megahertz. One two one point five megahertz gives two point four seven metres; three hundred and seventy-five kilohertz, which is nought point three seven five megahertz, gives eight hundred metres. Convert the units first: that is where marks are lost. The bands climb in factors of ten, each starting with a three, from very low frequency at three kilohertz up through high, very high, ultra high and super high frequency. The chart puts the aviation services in their bands. And phase can only be compared between two signals of the same frequency.
Radio propagation
Line of sight, the ionosphere and skip distance 0 10000 20000 30000 40000 0 50 100 150 200 250 300 Aircraft height (ft) Line-of-sight range (nm) 10 000 ft: 123 nm 172 nm station at sea level station at 1600 ft (√ = 40) R = 1.23 (√H1 + √H2 ) · power does not extend it Tx lower f higher f shorter skip surface wave dead space (higher f) D layer: about 75 km, day only E layer: about 125 km F layer: about 225 km (F1, F2 by day) More ionisation (day) → shorter skip · higher f → longer skip Range (nm) = 1.23 (√H1 + √H2 ), heights in feet · more ionisation → shorter skip · higher frequency or higher layer → longer skip · OWF ≈ 0.85 MUF · half-wave dipole ≈ 0.95 × λ/2.
Chapter 21 · Revision and Exam Practice
22
e-books by eatpl.in · © 2026 · Do not copy or distribute
Propagation has one formula and a set of directions. VHF and above travel by the space wave, in line of sight, and the range in nautical miles is one point two three times the sum of the square roots of the two heights in feet. An aircraft at ten thousand feet sees a sea-level station at one hundred and twenty-three miles, and more power does not help beyond the horizon. On the right is the ionosphere: the D layer at about seventy-five kilometres exists only by day, then the E layer at about one hundred and twenty-five and the F layer at about two hundred and twenty-five. HF uses the sky wave. More ionisation bends the wave down sooner, so the skip distance shortens; a higher frequency, or refraction from a higher layer, gives a longer skip and a larger dead space. Low and medium frequencies use the surface wave, which goes further over the sea.
Worked calculations
The calculations that come up every time Calculation Formula Worked example Ohm’s law and power V = I R · P = V I = I² R = V² ÷ R 4 A through 5 Ω: 20 V and 80 W Battery capacity Ah = amps × hours · test ≥ 80 % 60 Ah at the 10-hour rate: 6 A · 42 min of 60: 70 %, reject Time constant τ = C × R 100 µF × 10 kΩ = 1 s ; full charge after about 5 s AC frequency, r.m.s. f = p × rpm ÷ 120 · r.m.s. = 0.707 × peak 8 poles at 6000 rpm: 400 Hz · 162.6 V peak: 115 V Power factor kW = kVA × p.f. 90 kVA at 0.8: 72 kW (and 54 kVAR) Transformer E₂ ÷ E₁ = N₂ ÷ N₁ 200 V, 1000 → 140 turns: 28 V Motor speed NS = 120 f ÷ p · slip = (NS − N) ÷ NS 4 poles, 400 Hz: 12 000 rpm; 5 % slip: 11 400 rpm Radio λ = 300 ÷ f (MHz) · range = 1.23 (√H₁ + √H₂) 121.5 MHz: 2.47 m · 10 000 ft to sea level: 123 nm
Write the formula first, put the units right (MHz and metres, feet and nautical miles, µF and kΩ), then check the size of the answer.
Chapter 21 · Revision and Exam Practice
23
e-books by eatpl.in · © 2026 · Do not copy or distribute
Here are the calculations that turn up in almost every paper, each with a worked example. Four amps through five ohms drops twenty volts and uses eighty watts. A sixty ampere hour battery at the ten-hour rate gives six amps; in a capacity test, if it lasts only forty-two minutes at its one-hour rate it is at seventy per cent and must be rejected. A hundred microfarads and ten kilohms give a time constant of one second. Eight poles at six thousand rpm give four hundred hertz, and a peak of a hundred and sixty-two point six volts is a hundred and fifteen volts r.m.s. Ninety k V A at a power factor of nought point eight is seventy-two kilowatts. A transformer with a thousand primary and a hundred and forty secondary turns turns two hundred volts into twenty-eight. A four-pole induction motor on four hundred hertz with five per cent slip turns at eleven thousand four hundred rpm.
Classic traps
Where marks are lost Fuses Replace once only , correct rating, circuit switched off. Never uprate. Spares by law: 10 %, at least 3.
Breakers A trip-free breaker cannot be reset while the fault is still there. It does not reset itself.
Ni-Cd battery Hydrometer and voltage show nothing . Hot after a start, current rising: thermal runaway .
Battery checks Voltage on load . Series adds volts , not ampere hours.
Cut-outs Closed by rising generator voltage ; opened by reverse current . A generator failure never stops the engine.
Load sharing Real (kW) ↔ CSD torque . Reactive (kVAR) ↔ excitation . Wild frequency: never in parallel.
Hand rules and motors Left = motor , right = generator . Synchronous motor: DC rotor . Induction: no brushes.
Radio 300 ÷ f needs MHz and metres . Higher f → longer skip. Range set by heights, not power .
Chapter 21 · Revision and Exam Practice
24
e-books by eatpl.in · © 2026 · Do not copy or distribute
These are the places where marks are lost. A blown fuse is replaced once only, with the correct rating, and never a bigger one; and spares are a legal requirement. A trip-free breaker cannot be reset while the fault remains, and no breaker resets itself. A nickel-cadmium battery hides its state of charge from both the hydrometer and the voltmeter, and one that runs hot after a start, with rising charge current, suggests thermal runaway. Check any battery’s voltage on load, and remember that series connection adds volts, not capacity. The cut-out closes as generator voltage rises and opens on reverse current, and losing a generator never stops an engine. Real load is shared through the drive, reactive load through the excitation. Left hand for motors, right hand for generators; the synchronous motor has the DC on its rotor. And in radio, convert to megahertz and metres first, remember that a higher frequency gives a longer skip, and that line-of-sight range depends on height, not power.
Method and summary
How to answer, and your last-minute numbers 1 · Read the stem Underline NOT, EXCEPT, increase, decrease, normally. Many wrong options are true about a different case.
2 · Name the job Ask what the device is for: limit, isolate, convert, share, protect. The job usually names the answer.
3 · Which way? For any failure ask which way it goes: open or closed, rise or fall, lead or lag, longer or shorter.
4 · Units first Write the formula, convert kHz, GHz, cm, µF, kΩ, then check the size of the answer.
DC numbers 28 V bus for 24 V battery · lead-acid 2.2 / 2.0 / 1.8 V, SG 1.27 → 1.17 · Ni-Cd 1.2 V · 80 % test · 30 min.
AC numbers 115/200 V, 400 Hz (380–420) · 0.707 · 1.73 · f = p × rpm ÷ 120 · NS = 120 f ÷ p · 5 % slip.
Electronics Si 0.6–0.7 V · Ge 0.2–0.3 V · donor 5, acceptor 3 · byte = 8 bits · RAM volatile.
Radio 3 × 10⁸ m/s · λ = 300 ÷ f · 1.23 √H · D 75, E 125, F 225 km · OWF 0.85 MUF.
Chapter 21 · Revision and Exam Practice
25
e-books by eatpl.in · © 2026 · Do not copy or distribute
Finish with a method, then the list. First, read the stem and underline the small words, not, except, increase, decrease, normally, because many wrong options are true statements about a different case. Second, name the job of the device: a component that limits, isolates, converts or shares usually tells you its own name. Third, for any failure or change, ask which way it goes. Fourth, convert the units first, then check the size of the answer. Then the last-minute numbers. DC: a twenty-eight volt bus for a twenty-four volt battery, lead-acid cells at two point two, two and one point eight volts, nickel-cadmium at one point two, the eighty per cent capacity rule and thirty minutes of battery. AC: one hundred and fifteen over two hundred volts at four hundred hertz, nought point seven oh seven and one point seven three. And for radio, three hundred over the frequency, and one point two three root H. Now go to the questions.