Electrics · Chapter 2
Switches, Relays and Solenoids How aircraft circuits are switched: toggles, switch lights and guards, micro and thermal switches, proximity detectors, time and centrifugal switches, and the relays and solenoids that let a small current control a large one.
© 2026 eatpl.in. For the personal study of eatpl.in students only. Do not copy or distribute.
e-books by eatpl.in · © 2026 · Do not copy or distribute
Welcome to chapter two: switches, relays and solenoids. Every circuit on an aircraft has to be started, stopped and steered, sometimes by a pilot’s finger, sometimes by the aircraft itself as a door closes, a temperature rises or an engine speeds up. In this chapter we meet the switches you will see on the flight deck, toggles, switch lights and guarded switches, and the ones you will never see: micro switches, thermal switches, proximity detectors, timers and centrifugal switches. Then we look inside relays and solenoids, the remotely operated switches that let a tiny current from the flight deck control hundreds of amps.
Chapter 2
Starting, stopping and steering current Every circuit needs something to make and break it. Some are worked by the crew, some by the aircraft itself.
Crew-operated Toggle switches, switch lights, guarded switches. Poles, throws, NO and NC.
Position and heat Micro switches for doors, gear and flaps. Bimetallic switches for overheat and fire warning.
No contact at all Proximity detectors: inductive, capacitive and magnetic. Time and centrifugal switches.
Remote switching Electromagnets, relays and solenoids: a small current controls a large one.
Chapter 2 · Switches, Relays and Solenoids
2
e-books by eatpl.in · © 2026 · Do not copy or distribute
This chapter is about how circuits are started, stopped and steered. Every circuit needs something that makes it and breaks it, and on an aircraft some of those switches are worked by the crew, while many more are worked by the aircraft itself. First we look at the crew-operated switches: toggles, switch lights and guarded switches, and the language used to describe them, poles and throws, normally open and normally closed. Then come the switches that sense position and heat: micro switches on doors, gear and flaps, and bimetallic switches for overheat and fire warning. After that, the sensors that switch without any contact at all, the proximity detectors, followed by time switches and centrifugal switches. Finally we look inside relays and solenoids, which let a small current from the flight deck control a very large one somewhere else on the aircraft.
Switching basics
Where a switch sits in a circuit Switches and relays initiate and control aircraft circuits A switch is fitted in series with the load it controls, in the supply line after the circuit breaker Open the switch and the load is dead ; the return is usually through the airframe (earth) Contacts are rated for a given current and voltage ; DC is harder to break than AC because the arc does not self-extinguish Normally open (NO) and normally closed (NC) describe contacts in their rest (unoperated) state28 V DC bus bar CB 1 protect 2 control 3 load earth return (airframe) Normally open (NO) Normally closed (NC)
Chapter 2 · Switches, Relays and Solenoids
3
e-books by eatpl.in · © 2026 · Do not copy or distribute
Switches and relays are what initiate and control the circuits on an aircraft. A switch is always fitted in series with the load it controls, and on a typical DC circuit it sits in the supply line, after the circuit breaker that protects the wiring. With the switch open, the load is dead, and the return to the battery is usually made through the metal airframe, which we call the earth return. Switch contacts are rated for a particular current and voltage. Breaking a DC current is harder than breaking AC, because a DC arc does not go out by itself as AC does when the current passes through zero, so DC contacts must open quickly and far. Two terms you will use all through this chapter: normally open and normally closed. They describe the contacts in their rest state, unoperated or de-energised. A normally open contact is open until operated; a normally closed contact is closed until operated.
Switching basics
Poles and throws SPST single pole, single throw simple ON–OFF SPDT single pole, double throw changeover: one input, two outputs DPST double pole, single throw two circuits ON–OFF together DPDT double pole, double throw two changeovers together Pole = number of separate circuits the switch controls. Throw = number of positions each pole can connect to.
Chapter 2 · Switches, Relays and Solenoids
4
e-books by eatpl.in · © 2026 · Do not copy or distribute
Switches are described by their poles and their throws. The number of poles is the number of separate circuits a switch controls at the same time. The number of throws is the number of different outputs each pole can be connected to. The simplest is single pole, single throw: one circuit, on or off. Single pole, double throw is a changeover switch: one common input that goes to one output or the other, for example selecting between two power sources for an instrument. Double pole, single throw switches two separate circuits on and off together, shown by the dashed mechanical link between the two blades; it is used where both the supply and the return of a circuit must be broken. Double pole, double throw is two changeover switches worked together. When you see these letters on a diagram, you can now picture exactly what the switch does.
Crew-operated switches
Toggle switches General-purpose lever switch, common on older aircraft and light aircraft Can carry several isolated contact sets inside one body Two-position : ON or OFFMulti-position, spring-biased to the centre or OFF: press and hold to select, e.g. trim, starterSome are lever-locked : pull the lever out before it will move OFF ON Two-position: ON or OFF UP OFF (centre) DOWN Spring-biased to centre: press and hold to select Lever-lock: pull out, then move Several isolated contact sets can sit inside one switch
Chapter 2 · Switches, Relays and Solenoids
5
e-books by eatpl.in · © 2026 · Do not copy or distribute
The toggle switch is the familiar general-purpose lever switch, still common in older and light aircraft. Inside the body there may be several sets of contacts, isolated from each other, so one lever can switch more than one circuit. When the pilot moves the lever over, the contacts inside close and, in our scene, the lamp lights from the twenty-eight volt supply. The simplest toggle has two positions, on and off. Others have three or more positions and are spring-biased back to the centre, or off, position. To select one direction the pilot must press and hold the lever; let go and it springs back. You find these on things like electric trim and engine starting, where the action should only last as long as the pilot holds it. Some toggles are lever-locked: the lever has to be pulled out before it can move, which prevents accidental selection.
Crew-operated switches
Switch lights: push-buttons with a legend Combine a push switch with an indicator light in the lens; they have largely replaced toggles on modern flight decks Momentary action : press and hold to activate, release to deactivateAlternate action : press and release to activate, press and release again to deactivateThe legend confirms the selected state (e.g. OFF, ON) or shows a warning calling for action (e.g. FAULT) FAULT OFF warning legend and selected state Momentary press output on only while held Alternate action press output press once ON, press again OFF Switch lights replace toggles on modern flight decks
Chapter 2 · Switches, Relays and Solenoids
6
e-books by eatpl.in · © 2026 · Do not copy or distribute
Switch lights have largely replaced toggle switches on modern flight decks. Each one combines a push-button switch with indicator lights built into its lens. There are two basic types, and the timing diagrams show the difference. A momentary action switch works only while you hold it: press and hold, and the output is on; let go, and it goes off. An alternate action switch latches: press and release once, and it switches on and stays on; press and release a second time, and it switches off. The lens legends do two jobs. One legend confirms the position you have selected, such as OFF or ON. The other gives a warning that calls for the switch to be pressed, such as an amber FAULT light. So a single square button both controls the system and tells you what state it is in.
Crew-operated switches
Guarded switches A hinged guard covers the switch to prevent inadvertent operation Used where a mistaken selection would be serious or irreversible Examples: generator (IDG) disconnect , fuel jettison (dump) master , emergency power Both toggles and switch lights can be guarded; the guard is often red Selecting becomes a deliberate two-step action: lift, then select closed hinge Guard down: cannot be knocked by accident Guard lifted: deliberate two-step action • Generator (IDG) disconnect • Fuel jettison (dump) master • Emergency electrical power • Engine fire handles: a guarded cousin
Chapter 2 · Switches, Relays and Solenoids
7
e-books by eatpl.in · © 2026 · Do not copy or distribute
Some switches would cause serious, or even irreversible, trouble if they were knocked by accident, so they are fitted with a guard. A guard is a hinged cover, often red, held shut by a spring over a toggle or a switch light. To operate the switch, the pilot must first lift the guard, and only then select the switch, so the action becomes deliberate, a two-step movement. Classic examples are the generator disconnect, or on modern jets the integrated drive generator disconnect, which on many types cannot be reconnected in flight; the fuel jettison, or dump, master switch; and switches for emergency power. In the exam, if you are asked why a switch is guarded, the answer is to prevent its inadvertent operation.
Position and heat
Micro switches Named for the very small movement between the make and break positions A snap-action spring flips the contact quickly and positively Detect the position of a device: door open or closed, gear up or down, flaps, levers Drive flight-deck indications , or control relays for a sequenced operation Largely replaced on modern aircraft by proximity detectors plunger: a tiny push snap-action spring NC NO COM NO NC Movement between make and break is tiny: hence "micro" Senses door, gear, flap and lever positions
Chapter 2 · Switches, Relays and Solenoids
8
e-books by eatpl.in · © 2026 · Do not copy or distribute
A micro switch is a small, sealed switch that is operated by a plunger, often with a roller lever on it. The name micro describes the very small movement between the make and break positions: a tiny push on the plunger trips an internal snap-action spring, which flips the moving contact quickly and positively from one fixed contact to the other. Most have three terminals, common, normally open and normally closed. Micro switches are used to detect the position of things: whether a door is open or closed, whether the landing gear is up or down, where the flaps are, or the position of a lever. Their output can light an indication on the flight deck, or energise relays so that operations happen in the right sequence, such as gear doors opening before the gear moves. On modern aircraft they have largely been replaced by proximity detectors, which have no moving contacts at all.
Position and heat
Bimetallic (thermal) switches Two metals with different expansion rates bonded into one strip When heated, the strip bends towards the metal that expands less, and moves a contact Set to operate at a chosen temperature : to give a warning, or to switch a circuit on or off Uses: fire detection circuits, battery overheat switch, oil temperature warning light The same principle trips a thermal circuit breaker (chapter 3) Cold: strip straight, contacts open heat Hot: strip bends, contacts close brass (expands more) on top invar / steel (expands less)
Chapter 2 · Switches, Relays and Solenoids
9
e-books by eatpl.in · © 2026 · Do not copy or distribute
A bimetallic switch is a temperature-sensitive switch. Its heart is a strip made of two different metals bonded together, one that expands a lot when heated, such as brass, and one that expands very little, such as invar or steel. One end of the strip is fixed. As the temperature rises, the high-expansion metal grows more than the low-expansion metal, so the strip bends towards the side that expands less. Watch the strip bend until its tip touches the fixed contact and closes the circuit, lighting the warning. The switch is set to operate at a chosen temperature, either to warn the pilot or to switch a circuit on or off. Typical uses are fire detection circuits, the battery overheat switch, and the oil temperature warning light. Remember this strip: exactly the same differential expansion is what trips a thermal circuit breaker, which we meet in chapter three.
No contact at all
Proximity detectors Electrical or electronic sensors that respond to the presence of a material without touching it. The response drives a switch, relay or transistor.
Inductive A coil whose inductance changes when a ferromagnetic target comes close. Needs a metal target. Landing gear.
Capacitive A capacitance change caused by nearby material. Detects any material , liquid or solid: fluid levels.
Magnetic A changing flux induces an EMF in a coil on a magnet. Needs a moving ferrous target: speed sensing.
Chapter 2 · Switches, Relays and Solenoids
10
e-books by eatpl.in · © 2026 · Do not copy or distribute
Proximity detectors are electrical or electronic sensors that respond to the presence of a material, without touching it. Their response is used to operate a switch, a relay or a transistor. There are many types, but three matter for the exam. The inductive type has a coil whose inductance changes when a ferromagnetic target comes close. The capacitive type senses a change of capacitance caused by any nearby material. The magnetic type uses a coil wound on a magnet, in which an EMF is induced when the magnetic flux changes, so it senses moving ferrous objects. Here is the key exam point: the inductive and magnetic types need the monitored material to be metal, but the capacitive type can sense either metal or non-metal materials, and even liquids. We will look at each in turn.
No contact at all
Inductive proximity sensors A coil in the sensor face sets up a field; a ferromagnetic target coming close changes its inductance The electronics detect the change and switch the output Hermetically sealed , actuated by the presence of the target, not by touching itUnaffected by dirt, ice and weather: highly reliable Used in landing gear systems in place of micro switches steel target sensor FAR field undisturbed output OFF steel target sensor NEAR inductance changes output ON Sealed unit · no moving parts · no contact Inductive and magnetic types need a metal target
Chapter 2 · Switches, Relays and Solenoids
11
e-books by eatpl.in · © 2026 · Do not copy or distribute
The inductive proximity sensor has a coil in its face, which sets up a magnetic field just in front of it. When a ferromagnetic target, a piece of steel, comes close, it changes the inductance of the coil. The sensor’s electronics detect that change and switch the output on. Move the target away and the output switches off again. There is always a small air gap; the target never touches the sensor. Because the sensor is a hermetically sealed unit, actuated simply by the presence of the target, it has no exposed moving parts or contacts to get dirty, iced up or worn, so it is unaffected by atmospheric conditions and highly reliable. That is why inductive sensors have replaced micro switches in many landing gear systems, which live in one of the dirtiest, wettest places on the aircraft.
No contact at all
A landing gear proximity switch system wing / wheel-well structure side brace downlock uplock door closed gear door Landing gear accessory unit PCB PCB PCB NOSE LEFT RIGHT gear lights and sequencing relays Each switch = sensor + target + circuit card blue = sensor on structure · gold = target Each proximity switch has three parts: a sensor on the structure, a target on the moving part, and a printed circuit card in the landing gear accessory unit.
Chapter 2 · Switches, Relays and Solenoids
12
e-books by eatpl.in · © 2026 · Do not copy or distribute
Here is how inductive sensors are used in a typical landing gear system. Each proximity switch is made up of three parts. First, a sensor, fixed to the appropriate landing gear structure, shown in blue. Second, a target, or actuator, fixed to the moving part right next to its sensor, shown in gold: for example on the downlock, the uplock and the gear door. Third, a printed circuit card, located in a box called the landing gear accessory unit, which contains the electronics for that sensor. When the gear is down and locked, the downlock target sits in front of its sensor and the card switches on. The cards then drive the gear indication lights on the flight deck and the relays that sequence the doors and the gear. Because nothing touches, the system is far more reliable than the micro switches it replaced.
No contact at all
Capacitive proximity sensors Detection by a capacitor whose capacitance changes when material comes near Extremely versatile: detects all materials , liquid and solid Ferrous and non-ferrous metals, and non-metals Used to detect high or low liquid levels in hydraulic and fuel systems fluid probe: its capacitance changes when covered Detects: metal targets non-metal solids liquids: fuel or hydraulic level Capacitive: works with any material
Chapter 2 · Switches, Relays and Solenoids
13
e-books by eatpl.in · © 2026 · Do not copy or distribute
The capacitive proximity detector works by sensing a change of capacitance. Its probe forms one side of a capacitor, and anything that comes near it, or covers it, changes the capacitance. You will learn exactly why in the next chapter, when we see that the material between the plates affects capacitance. The great strength of this type is that it can detect all materials, liquid and solid. It will sense ferrous and non-ferrous metals, and non-metals too. That makes it ideal for detecting liquid levels. A probe mounted at the high-level or low-level point in a hydraulic reservoir or a fuel tank changes its capacitance as the fluid covers or uncovers it, and that is used to give a level warning or to stop refuelling. So remember: if a question asks which proximity detector can sense a non-metal or a liquid, the answer is capacitive.
No contact at all
Magnetic sensors and toothed wheels A coil wound round a permanent magnet , placed close to a ferrous object When the flux changes, an EMF is induced ; its size depends on the rate of change of flux Mounted radially by a steel gear wheel : each tooth passing gives a pulse Output frequency = teeth passing per second , so it measures speed Used for engine N1 and N2 speeds and wheel speed (anti-skid) 0 0.25 0.5 0.75 1 -1 0 1 time (ms) induced EMF one tooth EMF depends on the rate of change of flux Example: 60 teeth at 6000 rpm 6000 ÷ 60 = 100 rev/s × 60 teeth = 6000 pulses/s Output frequency ∝ shaft speed Used for engine N1/N2 and wheel speed (anti-skid)
Chapter 2 · Switches, Relays and Solenoids
14
e-books by eatpl.in · © 2026 · Do not copy or distribute
The magnetic detector works on electromagnetic induction. In its simplest form a coil is wound round a permanent magnet, and one pole of the magnet is placed close to a ferrous object. If the object moves, the magnetic flux through the coil changes, and an EMF is induced in the coil. The faster the flux changes, the bigger the EMF. Now mount the sensor radially, close to the edge of a steel gear wheel. Each tooth passing the magnet is, in effect, a separate ferrous object, so every tooth produces a pulse, and a train of teeth produces a train of pulses. The output frequency equals the number of teeth passing the sensor per second, which is directly proportional to the shaft speed. For example, a sixty-tooth wheel turning at six thousand r p m gives six thousand pulses per second. This is how engine shaft speeds and wheel speeds for anti-skid are measured.
Other automatic switches
Time switches Time switches or time-delay relays act after a set interval They can be initiated electrically or mechanically Example: the APU air intake door closes 30 seconds after APU shutdown Other uses: delaying a warning to avoid nuisance alerts, sequencing loads after power-up 0 10 20 30 40 seconds after APU shutdown timer running APU shut down door closes Time switch / time-delay relay Started electrically or mechanically Acts only after a set interval has run Why wait here? The intake stays open while the APU runs down and cools
Chapter 2 · Switches, Relays and Solenoids
15
e-books by eatpl.in · © 2026 · Do not copy or distribute
A time switch, or time-delay relay, activates a circuit only after a set interval has passed. It can be started electrically or mechanically. A good example is the auxiliary power unit. When the APU is shut down, its air intake door does not close immediately; a timer runs, and about thirty seconds later the door is commanded closed. That gives the APU time to run down with air still able to flow through it. Time delays are used in many other places too: to stop a warning appearing for a brief, harmless fluctuation, which would be a nuisance alert, and to bring loads on line one after another rather than all at once when power is first applied. The exam simply wants you to know that a time switch operates a circuit after a specific time interval, and the APU intake door example.
Other automatic switches
Centrifugal switches Operated by shaft speed : flyweights swing outwards against a spring as rpm rises At a set rpm they activate or de-activate a circuit Can work as rpm increases or decreases Example: the starter motor cut-out switch , which disconnects the starter once the engine is running fast enough rotating shaft low rpm: weights in contacts CLOSED high rpm: weights out contacts OPEN 0 25 50 75 100 125 shaft speed (% of cut-out speed) closed open
Chapter 2 · Switches, Relays and Solenoids
16
e-books by eatpl.in · © 2026 · Do not copy or distribute
A centrifugal switch is operated by the speed of a rotating shaft. Inside it, small flyweights are held in by a spring. As the shaft speeds up, centrifugal force throws the weights outwards against the spring, and at a set speed they move far enough to open, or close, a set of contacts. So the switch can activate or de-activate a circuit as the r p m of a device increases or decreases. The classic example is the starter motor cut-out. During an engine start, the starter turns the engine until it is running fast enough to keep going by itself. At that speed the centrifugal switch opens and disconnects the starter, so that the starter is not over-sped by the engine and is not left running. The graph shows the idea: contacts closed at low speed, then open once the cut-out speed is reached.
Relays and solenoids
Why we switch remotely Solenoids and relays are remotely controlled switches A small current from the flight deck switches a large current at the relay or solenoid Heavy cables stay short : less weight, less voltage drop, less fire risk The coil is insulated : no physical or electrical contact with the circuit it controls Example: the starter solenoid in a piston engine starting circuit flight deck thin wire · ≈ 0.5 A coil pulls contacts battery M starter: hundreds of amps Small current switches a large current far away No heavy cables to the flight deck: less weight, less volt drop, less fire risk
Chapter 2 · Switches, Relays and Solenoids
17
e-books by eatpl.in · © 2026 · Do not copy or distribute
Solenoids and relays are nothing more than remotely controlled switches. Think about an engine starter motor, which can draw hundreds of amps. If that current had to go through a switch on the flight deck, you would need very thick, heavy cables running all the way to the cockpit and back, with a big voltage drop and a real fire risk. Instead, the pilot’s switch carries only a small current, perhaps half an amp, along a thin wire to the coil of a relay or solenoid placed close to the battery and the motor. The coil becomes an electromagnet and pulls heavy-duty contacts closed, and the large current flows through short, thick cables. Note that the coil is wound of insulated wire and has no physical or electrical contact with the circuit that is controlled by the contacts. The control circuit and the load circuit are completely separate.
Relays and solenoids
The electromagnet inside A solenoid coil : many turns of insulated wire; its field is like a bar magnet Right-hand grasp rule : fingers curl with the conventional current, thumb points to the north pole Strength rises with more turns , more current and a soft-iron core Switch off and the field collapses , leaving a little residual magnetism in soft iron S N thumb → north pole I Make the field stronger: • more turns on the coil • more current • a soft-iron core Switch off: the field collapses, leaving only a little residual magnetism in soft iron
Chapter 2 · Switches, Relays and Solenoids
18
e-books by eatpl.in · © 2026 · Do not copy or distribute
At the heart of every relay and solenoid is an electromagnet. A coil made of many turns of insulated wire, carrying a current, produces a magnetic field just like a bar magnet’s, with a north pole at one end and a south pole at the other. To find which end is north, use the right-hand grasp rule. Grip the coil with your right hand so that your fingers curl round in the direction of the conventional current; your outstretched thumb then points to the north pole. You can make the field stronger in three ways: more turns on the coil, more current through it, or a soft-iron core inside it. Soft iron is chosen because it magnetises easily and loses its magnetism easily: when the current is switched off, the field collapses and only a little residual magnetism is left, so the relay lets go cleanly.
Relays and solenoids
The relay: fixed core, moving armature A stationary core inside the coil, and a hinged attracted armature De-energised: a return spring holds the armature away from the core Energised: the core attracts the armature, which moves the contacts NO contacts close and NC contacts open when the coil is energisedA heavy-duty relay is called a contactor , e.g. a generator line contactor or battery contactor hinge return spring NC NO fixed core and coil De-energised: spring holds NC closed, NO open Energised: armature pulled in, NO closed, NC open
Chapter 2 · Switches, Relays and Solenoids
19
e-books by eatpl.in · © 2026 · Do not copy or distribute
Here is the relay. Its coil is wound on a stationary soft-iron core, which is fixed to an L-shaped iron yoke. Across the top lies a hinged armature, a piece of iron that can pivot. When the coil is de-energised, a return spring holds the armature up, away from the core. In that rest position, the normally closed contact is made and the normally open contact is open. When a small control current flows and the coil is energised, the core becomes a magnet and attracts the armature down onto it. The armature carries the moving contact with it, so the normally closed contact opens and the normally open contact closes, and in our scene the heavy load lights up. Remove the current and the spring returns everything. A big, heavy-duty relay that switches main power, such as a generator line contactor or a battery contactor, is called a contactor.
Relays and solenoids
The solenoid: the core itself moves The solenoid has a moving core , or plunger , which is pulled into the coil The plunger can push a contact disc across heavy terminals, or move a mechanism directly Example: the starter solenoid , which switches the starter motor’s very large current Also used to operate valves, locks and latches Exam rule: solenoid = moving core ; relay = stationary core and attracted armature coil plunger pulled in when energised disc from battery M starter motor Solenoid: the core itself moves (plunger) Relay: fixed core, attracted armature
Chapter 2 · Switches, Relays and Solenoids
20
e-books by eatpl.in · © 2026 · Do not copy or distribute
The solenoid looks similar to a relay from the outside, but inside there is one key difference: the core itself moves. It is a soft-iron plunger, sitting partly outside the coil. When the coil is energised, the magnetic field pulls the plunger into the coil. In a starter solenoid, the plunger pushes a copper contact disc across two heavy terminals, bridging them, so the very large current can flow from the battery to the starter motor, which you can see start to spin. When the coil is switched off, a spring pushes the plunger back and the disc lifts off the terminals. Because the plunger produces a real, straight-line movement, solenoids are also used to operate valves, locks and latches directly. For the exam, learn this pair: a solenoid has a moving core, while a relay has a stationary core and an attracted armature.
Relays and solenoids
Contact and relay terms Term Meaning Example Normally open (NO) Open at rest; closes when the coil is energised Load switched on by a relay Normally closed (NC) Closed at rest; opens when the coil is energised Load switched off when another system runs Changeover (SPDT) One common contact moves from NC to NO Select between two supplies Contactor Heavy-duty relay for main power currents Battery or generator line contactor Solenoid Moving core (plunger) pulled into the coilStarter solenoid; valve actuation Relay Stationary core , attracted armatureMost switching and logic functions Time-delay relay Operates a set time after it is triggered APU intake door closing
"Normal" always means the rest (de-energised or unoperated) state, not the usual state in flight.
Chapter 2 · Switches, Relays and Solenoids
21
e-books by eatpl.in · © 2026 · Do not copy or distribute
This table gathers the terms you need. A normally open contact is open at rest and closes when the coil is energised; it is used to switch a load on. A normally closed contact is closed at rest and opens when the coil is energised, so it switches something off. A changeover contact has one common contact that moves from the normally closed side to the normally open side; that is a single pole, double throw arrangement, used to select between two supplies. A contactor is simply a heavy-duty relay for main power currents, like a battery contactor or a generator line contactor. A solenoid has a moving core; a relay has a stationary core and an attracted armature. And a time-delay relay operates a set time after it is triggered. One warning: normal always means the rest, de-energised state of the device, not whatever state it is usually in during flight.
Summary
What to take into the exam Toggles Two-position, or multi-position spring-biased to centre: press and hold. Several contact sets inside.
Switch lights Momentary: hold to activate. Alternate: press on, press again off. Legend shows state or warning.
Guarded Prevents inadvertent operation: generator disconnect, fuel jettison master.
Micro and thermal Micro: small make–break movement, senses position. Bimetal: differential expansion, overheat and fire warning.
Proximity Inductive and magnetic need metal; capacitive senses any material and liquids. Gear: sensor, target, PCB.
Time and rpm Time switch: APU intake door closes 30 s after shutdown. Centrifugal: starter cut-out.
Relays Remote switch: small current controls large. Stationary core, attracted armature. Coil isolated from contacts.
Solenoids Moving core (plunger). Starter solenoid. NO closes and NC opens when energised.
Chapter 2 · Switches, Relays and Solenoids
22
e-books by eatpl.in · © 2026 · Do not copy or distribute
Let us sum up. Toggle switches can be two-position, or multi-position and spring-biased to the centre, so you press and hold to select. Switch lights come in momentary action, active only while held, and alternate action, press on and press again for off, and their legends show either the selected state or a warning. Guarded switches prevent inadvertent operation, for example the generator disconnect and the fuel jettison master. Micro switches have a very small movement between make and break and sense position. Bimetallic switches use differential expansion for overheat and fire warnings. Among proximity detectors, the inductive and magnetic types need a metal target, while the capacitive type senses any material, including liquids. A time switch closes the APU intake door thirty seconds after shutdown, and a centrifugal switch cuts out the starter. Relays and solenoids let a small current control a large one; the relay has a stationary core and attracted armature, the solenoid a moving core.