Electrics · Chapter 14
Transformers, Rectifiers and TRUs How aircraft change AC from one voltage to another, turn it into DC, and turn DC back into AC: transformers, auto-transformers, rectifiers, TRUs and inverters.
AC in AC out, any voltage rectified: DC PRIMARY SECONDARY © 2026 eatpl.in. For the personal study of eatpl.in students only. Do not copy or distribute.
e-books by eatpl.in · © 2026 · Do not copy or distribute
Welcome to chapter fourteen: transformers, rectifiers and T R Us. An airliner makes its electrical power as one hundred and fifteen volt, four hundred hertz, three-phase AC, yet its instruments want twenty-six volts AC, its DC bus bars want twenty-eight volts DC, and in an emergency the battery must feed AC instruments. The boxes that make all of this possible are the subject of this lesson. We will see how a transformer changes voltage with almost no loss, why it only works on AC, what an auto-transformer saves and what it gives up, how diodes rectify AC into DC, why a three-phase rectifier gives a nearly steady output, and how a transformer rectifier unit and a static inverter fit into the aircraft system. Along the way we will work real numbers, because the exam loves turns ratios.
Roadmap
Changing AC and DC from one form to another AC supply 115/200 V 400 Hz Transformer AC → AC, new voltage Rectifier AC → DC TRU AC → 28 V DC Inverter DC → AC 1 · Transformers Mutual induction, the turns ratio, power balance, losses and the no-load current.
2 · Special types Three-phase transformers and the auto-transformer used for 26 V instrument supplies.
3 · Rectifiers Diodes, half-wave, full-wave bridge and six-diode three-phase rectifiers, and smoothing.
4 · TRUs and inverters AC to 28 V DC for the DC buses, and DC back to AC when the generators fail.
Chapter 14 · Transformers, Rectifiers and TRUs
2
e-books by eatpl.in · © 2026 · Do not copy or distribute
Here is our route through the chapter. The aircraft makes AC, but it needs electricity in several forms, so we need machines that change one form into another. First, the transformer: how it works by mutual induction, how the turns ratio sets the output voltage, and why the power out equals the power in. Second, two special types: the three-phase transformer, and the auto-transformer, which is often used to give twenty-six volts for instruments. Third, rectifiers, which turn AC into DC, from a single diode up to the six-diode three-phase bridge. And fourth, the two boxes you will meet on every airliner panel: the transformer rectifier unit, which feeds the DC bus bars, and the static inverter, which turns battery DC back into AC when the generators are lost.
Why transformers matter
The big advantage of AC AC voltage can be raised or lowered with extreme efficiency by a transformer A transformer has no moving parts ; efficiency is typically 95–99% Higher voltage means less current for the same power, so lighter cables and lower I²R losses Aircraft need several voltages: 115/200 V AC, 26 V AC for instruments, 28 V DC A transformer works only on AC : it needs a changing magnetic flux Same power, two voltages 2300 W delivered down the same cable 82 A at 28 V 20 A at 115 V cable loss ∝ I² 115 V: about 1/17 of the loss A transformer makes the change of voltage almost free
Chapter 14 · Transformers, Rectifiers and TRUs
3
e-books by eatpl.in · © 2026 · Do not copy or distribute
One of the biggest reasons aircraft use AC is that its voltage can be raised or lowered almost for free. A transformer has no moving parts, and a good one passes ninety-five to ninety-nine per cent of its input power to the output. Why does voltage matter? Look at the bars. To deliver two thousand three hundred watts at twenty-eight volts, you need about eighty-two amps. At one hundred and fifteen volts you need only twenty amps. The heat lost in a cable goes with the square of the current, so the higher voltage cuts the cable loss to about one seventeenth, and the cables can be lighter. But an aircraft also needs low voltages: twenty-six volts AC for many instruments and twenty-eight volts DC for the DC system. Transformers bridge those gaps. Remember one key limit from the start: a transformer only works on AC, because it depends on a changing magnetic flux.
Part 1 · Construction
A simple double-wound transformer Two electrically separate coils on a common laminated iron core The core forms a completely closed magnetic circuit The primary winding is connected to the AC supply The output is taken from the secondary winding Energy crosses from one winding to the other only by the magnetic flux Primary (N1) Secondary (N2) AC in load alternating flux Laminated soft-iron core: a closed magnetic circuit
Chapter 14 · Transformers, Rectifiers and TRUs
4
e-books by eatpl.in · © 2026 · Do not copy or distribute
A simple transformer is built from two coils of wire that are electrically separate from each other, wound over one common core made of thin iron laminations. The core is a closed ring, so it forms a completely closed magnetic circuit, and almost all the flux stays inside the iron. The primary winding is the one connected to the AC supply. The secondary winding is the one the output is taken from. Watch the flux appear: the alternating current in the primary sets up an alternating flux that runs round the core and through the secondary. There is no wire joining the two windings; the energy crosses only by way of that shared flux. When we connect a load across the secondary, a current flows in it, and the light comes on. That is why this type is called a double-wound transformer: two windings, linked magnetically but isolated electrically.
How it works
Mutual induction: a changing flux makes a voltage Alternating primary current sets up an alternating flux in the core The changing flux cutting the secondary induces an e.m.f. of mutual inductance The secondary e.m.f. is 180° out of phase with the primary voltage Connect a load and a secondary current flows On steady DC the flux does not change: no output , and the primary may overheat Primary V Flux Secondary e flux lags V by 90° e₂ is 180° from V₁ Steady DC: no change of flux, no secondary voltage only the winding resistance limits the primary current
Chapter 14 · Transformers, Rectifiers and TRUs
5
e-books by eatpl.in · © 2026 · Do not copy or distribute
How does the voltage get across? The alternating current in the primary sets up a flux in the core that is always changing: growing, collapsing and reversing a few hundred times a second. Faraday tells us that a changing flux through a coil induces an electromotive force in it. Because the flux is shared, this is called an e m f of mutual inductance. In the graph, the flux lags the primary voltage by ninety degrees, and the induced secondary e m f is one hundred and eighty degrees out of phase with the primary voltage, the same way a back e m f opposes the voltage that causes it. Now the important trap. Feed a transformer with steady DC, and once the current has settled the flux stops changing, so there is no output at all. Worse, the only thing limiting the primary current is the small resistance of the wire, so the winding may overheat.
Why laminations
Losses, laminations and efficiency Copper losses : I²R heating in the windingsEddy currents : the changing flux induces currents in the iron itselfThin insulated laminations break the eddy paths into tiny loopsHysteresis : energy to keep re-magnetising the core; use soft iron or silicon steelAll small: transformers are very efficient, but the heat must still be removed Solid core Laminated core big eddy current loop heavy heating thin insulated sheets tiny loops, little heat Flux runs up the page; eddy currents circulate across it
Chapter 14 · Transformers, Rectifiers and TRUs
6
e-books by eatpl.in · © 2026 · Do not copy or distribute
No machine is perfect, so where does the small loss in a transformer go? First, copper losses: the current in the windings heats the wire, in proportion to the current squared times the resistance. Second, eddy currents. The core is a conductor sitting in a changing flux, so voltages are induced in the iron too, and in a solid core they drive large circulating currents that waste power as heat. The cure is to build the core from thin sheets, or laminations, insulated from each other. Each sheet only allows a tiny loop, so the eddy currents and their heating become small. Third, hysteresis: every cycle the iron must be magnetised one way, then the other, and that takes a little energy. Soft iron or silicon steel keeps this loss low. Add these together and the losses are only a few per cent, which is why the exam treats power in as equal to power out.
Part 1 · The numbers
Transformation ratio: step up and step down Step down 115 V 26 V N1 = 1000 N2 = 226 Step up 50 V 200 V N1 = 100 N2 = 400 r = 226 ÷ 1000 = 0.226 (less than 1) r = 400 ÷ 100 = 4 (more than 1) Transformation ratio r = N2 / N1 = E2 / E1 volts per turn is the same on both windings r > 1: step up · r < 1: step down The volts per turn are the same in both windings, so the voltages are in the same ratio as the turns .
Chapter 14 · Transformers, Rectifiers and TRUs
7
e-books by eatpl.in · © 2026 · Do not copy or distribute
The key number for any transformer is its transformation ratio, written r. It is the number of turns on the secondary, N two, divided by the number of turns on the primary, N one. Because the same flux links every turn of both windings, each turn has the same voltage induced in it, so the voltages are in the same ratio as the turns: r equals N two over N one, which also equals E two over E one. If r is greater than one, the secondary has more turns and the voltage goes up: a step-up transformer. If r is less than one, it is a step-down transformer. On the left, one thousand turns feeding two hundred and twenty-six turns gives a ratio of nought point two two six, turning one hundred and fifteen volts into twenty-six volts. On the right, one hundred turns feeding four hundred turns gives a ratio of four, so fifty volts becomes two hundred volts.
Worked examples
Using the ratio: practice with real numbers Given Working Answer 115 V in, 26 V needed, primary 1150 turns N2 = 1150 × 26 ÷ 115 260 turns (step down, r = 0.226)200 V in, primary 1000 turns, secondary 140 turns E2 = 200 × 140 ÷ 1000 28 V Primary 500 turns, secondary 2000 turns, 50 V in r = 2000 ÷ 500 = 4 200 V (step up)Transformer halves the voltage r = 0.5 half the turns on the secondary, twice the current 26 V secondary must give 8 A; primary at 115 V I1 = 26 × 8 ÷ 115 1.81 A in the primarySecondary voltage greater than primary r > 1 step-up transformer
Check the answer is sensible: a step-down transformer always has fewer secondary turns, a lower secondary voltage and a higher secondary current.
Chapter 14 · Transformers, Rectifiers and TRUs
8
e-books by eatpl.in · © 2026 · Do not copy or distribute
Let us practise, because these are quick marks in the exam. First line: one hundred and fifteen volts in, twenty-six volts wanted, with eleven hundred and fifty primary turns. Multiply eleven hundred and fifty by twenty-six over one hundred and fifteen and you get two hundred and sixty secondary turns. Second: two hundred volts across one thousand turns, with one hundred and forty secondary turns, gives twenty-eight volts. Third: five hundred turns to two thousand turns is a ratio of four, so fifty volts becomes two hundred. Fourth, a favourite question: a transformer that halves the voltage has half as many turns on the secondary, and, because power is conserved, twice the current. Fifth: a twenty-six volt secondary giving eight amps takes two hundred and eight volt-amps, so at one hundred and fifteen volts the primary draws about one point eight one amps. And if the secondary voltage is the greater, it is a step-up transformer.
Power balance
Power out equals power in Ignoring the small losses: power in = power out In each winding, power = voltage × current So I2 / I1 = N1 / N2 : the current changes the opposite way to the voltage Step-down: lower voltage, higher current , so thicker wire on the secondary A transformer can never give out more power than it takes in 115 V 2 A 26 V 8.85 A thin wire, many turns thick wire, few turns P in = 115 × 2 = 230 VA = 26 × 8.85 = P out I2 / I1 = N1 / N2: volts down, amps up
Chapter 14 · Transformers, Rectifiers and TRUs
9
e-books by eatpl.in · © 2026 · Do not copy or distribute
If we ignore the very small losses, the power that goes into a transformer equals the power that comes out. In either winding, the power is the voltage times the current. So if the voltage is stepped down, the current must be stepped up by the same ratio, and the other way round. In the example, the primary takes two amps at one hundred and fifteen volts, which is two hundred and thirty volt-amps. The secondary gives twenty-six volts, so to pass the same two hundred and thirty volt-amps it delivers about eight point eight five amps. That is why the low-voltage winding of a step-down transformer is wound with fewer turns of thicker wire: it carries the bigger current. Watch for the exam trap: a step-up transformer does not increase power. It raises the voltage and lowers the current, and the power output is the same as the power input.
No load
No load: almost no primary current With the secondary open circuit , no secondary current flows The primary then draws only a small magnetising current : negligible The primary’s own back e.m.f. almost balances the supply voltage Add load: the secondary current’s flux opposes the core flux, so the primary draws more The transformer automatically takes from the supply what the load needs 0 2 4 6 8 0.5 1.0 1.5 2.0 Secondary (load) current, A Primary current, A ← no load: small magnetising current only step-down 4 : 1
Chapter 14 · Transformers, Rectifiers and TRUs
10
e-books by eatpl.in · © 2026 · Do not copy or distribute
What happens when nothing is connected to the secondary? With no load, no secondary current flows, and the primary behaves like a large inductor. The changing flux induces a back e m f in the primary itself that almost exactly balances the supply voltage, so only a small magnetising current flows, just enough to keep the flux going. In the exam, that current is described as negligible. Now connect a load. The secondary current creates its own flux, which opposes the core flux. That would reduce the back e m f in the primary, so the primary immediately draws more current to restore the flux. The graph shows the result for a four to one step-down transformer: the primary current starts at a small magnetising value and then rises in step with the load current, at one quarter of it. The transformer automatically takes from the supply what the load demands.
Part 2 · Special types
Three-phase transformers A three-phase output can be transformed by three single-phase transformers Or by one three-phase transformer Three laminated iron limbs , one per phase, joined by common yokes Each limb carries the primary and secondary of its own phase One core is lighter and smaller than three separate units Phase A Phase B Phase C inner: primary · outer: secondary or three single-phase transformers: A B C
Chapter 14 · Transformers, Rectifiers and TRUs
11
e-books by eatpl.in · © 2026 · Do not copy or distribute
Aircraft generators produce three-phase power, so how do we transform it? There are two ways. You could use three single-phase transformers, one for each phase. Or you can use one three-phase transformer, which is what you see here. It has three laminated iron limbs joined by common yokes at the top and bottom. Each phase has its own limb: phase A on the first, phase B on the middle limb, and phase C on the third. On each limb the primary and the secondary of that phase are wound together, the primary on the inside and the secondary around it. Because the three phase fluxes are one hundred and twenty degrees apart, they add up to zero at every instant, so the yokes can share their paths and there is no need for a return limb. The result is lighter and smaller than three separate transformers, which matters on an aircraft.
Auto-transformer
One winding does both jobs A single winding on a laminated core: part of it is both primary and secondary A tapping gives the output; it can step down or, sometimes, step up Common use: 26 V AC for instruments from the 115 V supply The common section carries the difference of the two currents, so less copper Cheaper and lighter, but no electrical isolation 115 V 26 V I1 = 0.90 A I2 = 4 A common turns carry 4 − 0.90 = 3.1 A No electrical isolation: input and output are joined
Chapter 14 · Transformers, Rectifiers and TRUs
12
e-books by eatpl.in · © 2026 · Do not copy or distribute
An auto-transformer uses only a single winding on a laminated core. The whole winding is connected across the supply, and the output is taken from a tapping part-way along, so some of the turns belong to both the primary and the secondary. On aircraft it is mainly used to step one hundred and fifteen volts down to twenty-six volts AC for instruments, although it can also be made to step up. Now look at the common section, the turns shared by input and output. It carries both currents, but they flow in opposite directions, so it actually carries only the difference. In our example the load takes four amps, the supply gives about nought point nine amps, and the common turns carry only about three point one amps. Less current means thinner wire, so an auto-transformer is cheaper and lighter. The price is that the input and output are joined, so there is no electrical isolation.
Side by side
Double-wound or auto-transformer? Feature Double-wound transformer Auto-transformer Windings Two separate coils One coil with a tappingLink between input and output Magnetic only Magnetic and electrical Electrical isolation Yes No Copper, weight and cost More Less : common turns carry the difference currentTypical aircraft use Isolating supplies, TRU input, current transformers 26 V AC instrument suppliesTurns ratio rule E2/E1 = N2/N1 Same rule, using the tapped turns
An auto-transformer cannot be used where the output circuit must be isolated from the supply.
Chapter 14 · Transformers, Rectifiers and TRUs
13
e-books by eatpl.in · © 2026 · Do not copy or distribute
Here are the two types side by side. A double-wound transformer has two separate coils linked only magnetically, so the output circuit is electrically isolated from the supply. That isolation is important for safety and for many circuits, which is why double-wound transformers are used at the input of T R Us and wherever the output must float free of the supply. An auto-transformer has one coil with a tapping, so the input and output are joined both magnetically and electrically. It uses less copper, because the common turns carry only the difference current, so it is cheaper and lighter, and that makes it a good choice for twenty-six volt AC instrument supplies. The turns ratio rule is the same for both. The exam question to expect: what is an auto-transformer? Answer: a transformer with only one coil, used as both the primary and the secondary.
Part 3 · Rectifiers
The diode: an electrical non-return valve A rectifier converts AC into DC A diode has low resistance one way and high resistance the other The symbol’s arrow points the way of conventional current : anode to cathode Also used as a blocking diode to stop reverse current in DC systems A Zener diode is designed to conduct in reverse at a set voltage anode cathode conventional current: low resistance this way forward: conducts above ~0.6 V reverse: blocks breakdown (Zener) V I
Chapter 14 · Transformers, Rectifiers and TRUs
14
e-books by eatpl.in · © 2026 · Do not copy or distribute
Now we move from changing voltage to changing AC into DC. A device that converts alternating current into direct current is called a rectifier, and its basic element is the diode. A diode has a very low resistance in one direction and a very high resistance in the other, so it behaves like an electrical non-return valve. In the symbol, the triangle points in the direction of conventional current flow, from the anode to the cathode. The curve shows the behaviour: in the forward direction a silicon diode starts to conduct strongly at about nought point six volts, while in reverse almost nothing flows. Besides rectifying, diodes are used as blocking diodes in DC systems, to stop current flowing back where it should not, for example from a bus into a failed source. And some diodes, called Zener diodes, are designed to break down and conduct in reverse at a set voltage, which makes them useful as voltage references.
Rectifiers 1
Half-wave rectification secondary diode load Input (AC) Output (pulsating DC) dashed: average ≈ 0.32 × peak one pulse per cycle: same frequency as the input; the negative halves are blocked One diode passes only one half of each cycle. The output is pulsating DC with gaps, at the same frequency as the input.
Chapter 14 · Transformers, Rectifiers and TRUs
15
e-books by eatpl.in · © 2026 · Do not copy or distribute
The simplest rectifier is a single diode in the secondary circuit of a transformer. When the top of the secondary is positive, the diode conducts and current flows through the load. When the polarity reverses, the diode blocks, and nothing flows. So the load sees only the positive half of each cycle, with the bottom half removed. This is half-wave rectification. Look at the output: it is DC in the sense that it always flows the same way, but it is very lumpy, with a gap for every half-cycle. There is one pulse per input cycle, so the output frequency is the same as the input frequency, and the average value is only about a third of the peak. Half the available energy is simply thrown away. For anything serious we need to use both halves of the cycle.
Rectifiers 2
Full-wave bridge rectifier Four diodes in a bridge use both halves of the cycleEach half-cycle, two diodes conduct and two block Current through the load is always in the same direction The gaps are filled: two pulses per cycle A capacitor across the output smooths it further D1 D2 D3 D4 + − load 1st half: D1, D4 2nd half: D2, D3 two pulses per cycle (ripple 2f)
Chapter 14 · Transformers, Rectifiers and TRUs
16
e-books by eatpl.in · © 2026 · Do not copy or distribute
To fill in the gaps, we use a bridge rectifier of four diodes. Follow the current in the 3D view. On the first half-cycle the top supply terminal is positive: current flows through diode one to the positive side of the load, through the load, and back through diode four. Diodes two and three are reverse biased and block. Now the supply reverses: current flows through diode two, through the load in exactly the same direction as before, and back through diode three. In every half-cycle, one half of the bridge presents a high resistance while the other half conducts easily, and the arrangement is designed so that the output always has the same polarity. The result is full-wave rectification, with two pulses for every input cycle and no gaps. The output is still bumpy, though, and a capacitor placed across it can smooth it to some extent.
Smoothing
The smoothing capacitor A capacitor across the output charges near each peak Between peaks it discharges into the load , filling the dips The remaining variation is called ripple A bigger capacitor or a lighter load gives less ripple Three-phase rectifiers need very little smoothing with capacitor: ripple ≈ 11% of peak dashed: without capacitor capacitor charges near each peak and feeds the load as the voltage falls
Chapter 14 · Transformers, Rectifiers and TRUs
17
e-books by eatpl.in · © 2026 · Do not copy or distribute
A capacitor connected across the output of a rectifier acts like a small reservoir. As the rectified voltage rises towards each peak, the capacitor charges up. When the voltage starts to fall, the diodes stop conducting and the capacitor discharges into the load, so the voltage falls only slowly until the next pulse arrives and tops it up again. The dashed line is the raw full-wave output; the green line is what the load sees with the capacitor fitted. What is left is a small up-and-down variation called ripple, here about 11 per cent of the peak. A larger capacitor, or a lighter load, gives less ripple, because the capacitor discharges less between pulses. In a single-phase supply smoothing is essential for electronics, but as we will see next, a three-phase rectifier produces so little ripple that it needs very little smoothing at all.
Rectifiers 3
Three-phase full-wave rectifier: six diodes A B C + DC − DC six diodes: each phase has one to + and one to − Phase voltages A, B, C (120° apart) DC output follows the highest line voltage 6 pulses per cycle · ripple ≈ 13% of peak · almost steady Six diodes in a bridge rectify all three phases. The output follows the tops of the line voltages: essentially steady DC .
Chapter 14 · Transformers, Rectifiers and TRUs
18
e-books by eatpl.in · © 2026 · Do not copy or distribute
Aircraft AC is three-phase, and a three-phase supply is rectified with a bridge of six diodes, two for each phase: one connecting that phase to the positive output and one to the negative output. At any instant, the diodes connected to the most positive phase and the most negative phase conduct, so the output always follows whichever line voltage is highest at that moment. The graph shows the result. The output never falls further than about thirteen per cent below its peak, and there are six pulses per input cycle, so at four hundred hertz the ripple is at two thousand four hundred hertz, which is very easy to filter. That is why the output of a three-phase rectifier is described as essentially steady, and why aircraft T R Us are always multi-phase units.
Part 4 · TRUs
The transformer rectifier unit A TRU combines a transformer and a rectifier in one unit Typically 115/200 V, 400 Hz, three-phase AC in, 28 V DC out Supplies the DC needs of an aircraft with an AC main system Always multi-phase for a smooth DC output Cooling air is drawn through; an overheat warning may be fitted Output current (amps) shown on the electrical panel TRU step-down transformer diode rectifier 115/200 V 3-phase 400 Hz 28 V DC to DC bus cooling air drawn through overheat warning output ammeter on the panel air
Chapter 14 · Transformers, Rectifiers and TRUs
19
e-books by eatpl.in · © 2026 · Do not copy or distribute
On an aircraft whose main generators produce AC, the DC loads are fed by transformer rectifier units, or T R Us. A T R U converts AC at one voltage into DC at another by combining a transformer and a rectifier in one box. Typically, one hundred and fifteen over two hundred volt, four hundred hertz three-phase AC goes in. The transformer steps it down, and a multi-diode rectifier on a heat sink turns it into twenty-eight volts DC for the DC bus bars. T R Us are always multi-phase units, because that gives a smooth DC output with almost no ripple. The diodes and windings make heat, so a cooling fan draws air through the unit, and its temperature may be monitored, with an overheat warning on the flight deck. The output current of each T R U, in amps, can be shown on the main electrical panel, so the crew can see that it is working and sharing the load.
In the system
Where the TRUs sit in a typical airliner AC BUS 1 AC BUS 2 AC ESS BUS TRU 1 AC → 28 V DC TRU 2 AC → 28 V DC ESS TRU AC → 28 V DC DC BUS 1 DC BUS 2 DC ESS BUS BATTERY BUS STATIC INVERTER charges the batteries → AC essential (emergency) The AC buses feed the TRUs, the TRUs feed the DC buses, and the batteries are charged from the DC buses . With all AC lost, the batteries feed the essential buses and the static inverter.
Chapter 14 · Transformers, Rectifiers and TRUs
20
e-books by eatpl.in · © 2026 · Do not copy or distribute
Here is how the T R Us fit into a typical airliner. Each AC bus feeds its own T R U: A C bus one feeds T R U one, which feeds D C bus one, and the same on side two. Many aircraft add an essential T R U so the most important DC loads keep their supply. Notice where the battery sits. The battery bus, and the batteries themselves, are kept charged from the DC buses, which means that in normal flight the battery is being charged through a T R U. That is a point Indian exams like to test. If all the AC generation is lost, the T R Us lose their input, and the batteries take over the essential DC buses. They also feed a static inverter, which makes AC for the essential AC instruments. The exact layout differs between types, but this pattern, AC to T R U to DC, with the battery as the emergency source, is the one to remember.
Inverters
The static inverter: DC back to AC An inverter converts DC to AC In constant-frequency aircraft: the emergency AC source , powered by the battery if the AC generators fail Modern inverters are solid-state (static) , transistorised; rotary inverters are largely obsolete Frequency-wild aircraft (e.g. ATR 42 , ATP ): wild AC → DC → inverter → constant-frequency AC Output monitored for voltage and frequency ; cooled like a TRU Constant-frequency aircraft: emergency Battery 24–28 V Static inverter AC ess. 115 V used when all AC generators have failed Frequency-wild aircraft: normal supply Wild AC Rectify Inverter 400 Hz frequency varies with engine speed, so instruments get constant-frequency AC from inverters Output monitored for voltage and frequency; cooled like a TRU
Chapter 14 · Transformers, Rectifiers and TRUs
21
e-books by eatpl.in · © 2026 · Do not copy or distribute
An inverter does the opposite job to a rectifier: it converts DC into AC. On an aircraft with a constant-frequency AC system, the static inverter is the emergency AC source. If the AC generators fail, the inverter is powered from the battery and supplies constant-frequency AC, typically one hundred and fifteen volts at four hundred hertz, to the flight instruments and other essential AC consumers. Modern inverters are solid-state, or static, using transistors; the old rotary inverter, a DC motor driving an alternator, is no longer used on modern aircraft. Some turboprops, such as the A T R forty-two and the B Ae A T P, have frequency-wild AC generators, whose frequency changes with engine speed. Their instruments need a steady frequency, so the wild AC is first changed into DC, and static inverters then make controlled constant-frequency AC as the normal supply. Inverter output is monitored for voltage and frequency, and it is cooled in the same way as a T R U.
Which box does what
Converters at a glance Device Input Output Typical aircraft use Double-wound transformer AC AC, other voltage, isolated Isolating and stepping supplies Auto-transformer AC AC, other voltage, not isolated 115 V → 26 V AC instruments Rectifier (diodes) AC DC Inside TRUs, brushless alternators, battery chargers TRU 115/200 V AC, 3-phase 28 V DC Normal DC supply in AC aircraft Static inverter DC (battery) 115 V AC 400 Hz Emergency AC; normal AC in frequency-wild types Blocking diode DC DC one way only Stops reverse current into a source
Remember the direction words: a rectifier and a TRU go AC to DC ; an inverter goes DC to AC .
Chapter 14 · Transformers, Rectifiers and TRUs
22
e-books by eatpl.in · © 2026 · Do not copy or distribute
Let us gather all the converters into one table. A double-wound transformer takes AC and gives AC at another voltage, with the output isolated from the input. An auto-transformer does the same, but without isolation, and on aircraft it typically turns one hundred and fifteen volts into twenty-six volts for instruments. A rectifier, made of diodes, turns AC into DC; you will find rectifiers inside T R Us, inside brushless alternators and in battery chargers. A T R U takes one hundred and fifteen over two hundred volt three-phase AC and delivers twenty-eight volts DC, and it is the normal DC source on an AC aircraft. A static inverter goes the other way, DC into AC, as the emergency AC source, or as the normal one on frequency-wild types. And a blocking diode lets DC through one way only. If you remember the direction words, rectifier AC to DC and inverter DC to AC, you will not be caught out.
Exam traps
Where marks are lost Power is not stepped up A step-up transformer raises voltage and lowers current . Power out = power in.
Turns ratio direction r = N2/N1 (secondary over primary). More secondary turns = step up .
Halving the voltage Needs half the secondary turns , and the secondary current doubles , not halves.
No load Open-circuit secondary: primary current is negligible (magnetising current only).
Auto-transformer One coil , primary and secondary in common. Not automatic, not frequency-changing, no isolation.
Rectifier frequency Half-wave output has the same frequency as the input; a 3-phase bridge gives almost steady DC.
Chapter 14 · Transformers, Rectifiers and TRUs
23
e-books by eatpl.in · © 2026 · Do not copy or distribute
Here are the places where students lose marks. First, a step-up transformer does not step up power; it raises voltage and lowers current, and the power out equals the power in. Second, the transformation ratio is secondary turns over primary turns, so more turns on the secondary means step up. Third, a transformer that halves the voltage needs half as many turns on the secondary, and the secondary current doubles; it does not halve. Fourth, with no load across the output, the primary current is negligible, just the small magnetising current. Fifth, an auto-transformer is simply one coil used as both primary and secondary. Do not be tempted by options saying it varies its ratio automatically or keeps the frequency constant, and remember it gives no isolation. And sixth, a half-wave rectifier gives pulses at the same frequency as the input, while a three-phase bridge gives almost steady DC.
Summary
What to take into the exam Transformer Two separate windings on a closed laminated core; mutual induction; AC only.
Ratio r = N2/N1 = E2/E1. r > 1 step up; r < 1 step down.
Power Power in = power out; I2/I1 = N1/N2. No load: negligible current.
Three-phase Three single-phase units or one core with three limbs.
Auto-transformer One winding with a tap; less copper; no isolation; 26 V instruments.
Rectifiers Diode = non-return valve. Half-wave, bridge (4 diodes), 3-phase (6 diodes): steady.
TRU 115/200 V 400 Hz 3-phase → 28 V DC. Multi-phase, fan-cooled, overheat warning, ammeter.
Inverter DC → AC. Battery-fed emergency AC; normal AC on frequency-wild types.
Chapter 14 · Transformers, Rectifiers and TRUs
24
e-books by eatpl.in · © 2026 · Do not copy or distribute
Let us sum up. A transformer has two electrically separate windings on a closed laminated core, and works by mutual induction, so it needs AC. Its transformation ratio is N two over N one, which equals E two over E one; above one it steps up, below one it steps down. Power in equals power out, so current changes the opposite way to voltage, and with no load the primary current is negligible. Three-phase power can be transformed by three single-phase units or by one three-limbed core. An auto-transformer has one winding with a tapping, uses less copper, gives no isolation, and is typically used for twenty-six volt instrument supplies. Diodes act as electrical non-return valves: one gives half-wave, four in a bridge give full-wave, and six give a nearly steady three-phase output. A T R U turns three-phase AC into twenty-eight volts DC, and a static inverter turns DC from the battery back into AC.