Engines · Chapter 26
APU and Engine Starting The auxiliary power unit and ram air turbine, the starting systems of gas turbines, the normal start sequence, and how to recognise and handle hot, wet and hung starts.
N2 EGT START starter → light-up → self-sustaining → idle © 2026 eatpl.in. For the personal study of eatpl.in students only. Do not copy or distribute.
e-books by eatpl.in · © 2026 · Do not copy or distribute
Welcome to the chapter on the auxiliary power unit and engine starting. Before the main engines run, an airliner still needs electricity, air conditioning and air to start its engines, and the A P U provides them. Then comes the start itself: the starter turns the engine, fuel and ignition come on, the engine lights and accelerates to idle. You will learn to read that sequence on two gauges, exhaust gas temperature and N two, and to recognise at once the three classic faults: the hot start, the wet start and the hung start, and exactly what to do about each.
Roadmap
Power on the ground, and bringing engines to life 1 · The APU What it supplies, its free turbine layout and its load compressor.
2 · APU operation In flight, controls, indications and automatic shutdown .
3 · The RAT Emergency hydraulic and electrical power from the airflow.
4 · Starters Requirements, air and electric starters, the sprag clutch .
5 · Normal start The sequence on EGT and N2 , self-sustaining speed, idle.
6 · Faults Hot , wet and hung starts, and the blow-out cycle.
7 · Relight and stop Windmill relights, shutdown by the HP cock, rundown time.
8 · Exam Traps, a summary, and practice questions.
Chapter 26 · APU and Engine Starting
2
e-books by eatpl.in · © 2026 · Do not copy or distribute
Here is our route. We begin with the auxiliary power unit, the A P U: what it supplies and why it is built as a free turbine with a load compressor. Then how it is used, in flight as well as on the ground, its few controls and indications, and the automatic shutdown that protects it. Third, the ram air turbine, which gives emergency power from the airflow. Fourth, starting systems: what any start needs, air and electric starters, and the sprag clutch. Fifth, the normal start read on two gauges. Sixth, the three faults every pilot must recognise: the hot start, the wet start and the hung start. Seventh, relighting, shutting down and rundown time. And finally the exam traps and a summary.
Part 1 · The APU
What the auxiliary power unit does A small gas turbine , usually in the tail cone , away from ground staff Powers electrical , pneumatic and (directly or indirectly) hydraulic systems Air for air conditioning and for engine starting Makes the aircraft independent of ground equipment Uses the aircraft’s own fuel system ; very high power for its weight APU in the tail cone safe for ground staff Electrical power its own generator, ground and air Pneumatic (bleed) air air conditioning and engine starting Hydraulic power through electric pumps, or on some types directly Independent of ground support equipment
Chapter 26 · APU and Engine Starting
3
e-books by eatpl.in · © 2026 · Do not copy or distribute
As aircraft became more complex, they needed power for their systems on the ground without running the main engines. That is the job of the auxiliary power unit. It is a small gas turbine, normally mounted in the tail, where its noise and exhaust will not harm people working around the aircraft. It provides electrical power from its own generator, and pneumatic air for air conditioning and for starting the main engines. Hydraulic power comes either through electric pumps or, on some types, directly. So the aircraft does not depend on ground power units or air carts at every airfield. A gas turbine is chosen because it gives very high power for its weight, and it can use the same fuel system as the main engines.
Part 1 · Layout
A free turbine turboshaft with a load compressor Normally a free turbine turboshaft : small, light, around 600 hp The free turbine drives the accessories through a gearbox Its compressor is not affected by changes of load on the free turbine The free turbine runs at constant speed : the generator gives constant frequency with no CSD Bleed air: from the APU compressor, or more commonly a separate load compressor Free turbine APU gearbox load compressor compressor combustor gas generator turbine free turbine Free turbine runs at constant speed : a 400 Hz generator needs no constant-speed drive. Load compressor supplies bleed air; the gas generator is not upset by changes of load. Around 600 hp.
Chapter 26 · APU and Engine Starting
4
e-books by eatpl.in · © 2026 · Do not copy or distribute
The usual layout is a free turbine turboshaft engine. It is small and light, yet produces around six hundred horsepower. A gas generator, with its own compressor, combustor and turbine, makes hot gas, and a separate free turbine on its own shaft extracts the power and drives the accessories through a gearbox. Because the free turbine is not mechanically tied to the compressor, changes in load do not upset the gas generator, which makes the unit very flexible. The free turbine is usually designed to run at a constant speed, so a generator driven by it gives a constant frequency without needing a separate constant-speed drive. Some A P Us supply air bled from their own compressor, but it is more common for the free turbine to drive a separate load compressor for the pneumatic services.
Part 2 · In flight
Using the APU in the air Developed for use in flight as a back-up power source after an engine failure Especially important for twins on long routes under ETOPS Must start at high altitude and run under load even higher Example: one type could start its APU up to 25 000 ft and draw power up to 31 000 ft Like any air-breathing engine, its power falls with altitude APU power falls with altitude
0
10
20
30
40
0
25
50
75
100
Pressure altitude (thousand ft)
Power available (% of sea level) start possible (example: to 25 000 ft) runs to 31 000 ft 45% at 25 000 ft Power follows air density (ISA density ratio shown) Started in flight as a back-up, e.g. after an engine failure
Chapter 26 · APU and Engine Starting
5
e-books by eatpl.in · © 2026 · Do not copy or distribute
The A P U was further developed so that it could run in the air too, giving a back-up source of power if a main engine fails. That matters most for twin-engine aircraft on long routes over water or remote areas under extended twin operations, E T O P S. The design philosophy is to keep it simple, rugged and reliable, but it must be able to start at high altitude and keep running under load even higher. One wide-body type, for example, could start its A P U up to twenty five thousand feet and draw power from it up to thirty one thousand feet. Like every engine that breathes air, its power falls as the air gets thinner. Following the density ratio, at twenty five thousand feet only about forty five per cent of the sea-level power is left.
Part 2 · Control
Few controls, few indications Indications: turbine temperature , speed and fault lights Controls: a start (power on) switch and a normal stop switch Plus a manual emergency shutdown and fire control Started by an electric starter from the aircraft battery Allowed to stabilise in rpm and temperature before taking load APU panel and indications START power on STOP normal FIRE / EMERG shut down + extinguish EGT RPM % FAULT Few controls: start, normal stop, emergency shut-down and fire. Few indications: turbine temperature, speed and fault lights. Automatic sensors do the protecting: they shut the APU down for fire, malfunctions or exceeded limits.
Chapter 26 · APU and Engine Starting
6
e-books by eatpl.in · © 2026 · Do not copy or distribute
Compared with the main engines, the pilot has very little in the way of A P U controls and indications. Typically you see the turbine temperature, the compressor speed and some fault lights. The controls are a power-on start switch, a normal stop switch and a manual emergency shutdown and fire suppression control. The A P U is easily started by an electric starter motor powered from the aircraft battery, so it needs no ground power. After start it is allowed to stabilise in r p m and temperature before it is asked to supply the aircraft’s systems. Because the pilot sees so little, the protection is automatic: sensors shut the unit down when something goes wrong, as the next slide shows.
Part 2 · Protection
Automatic shutdown of the APU Sensed condition Why it shuts the APU down Fire in the APU compartmentShuts down at once; on the ground the extinguisher is commonly fired automatically if the fire persists Overspeed A free-running rotor could burst Turbine over-temperature (high EGT)Protects the turbine; also acts as an overload limit Low oil pressure Bearings would fail High oil temperature Oil breakdown and bearing damage Other system malfunctions e.g. loss of control signal, failure to accelerate
Automatic shutdown also acts as a governor , protecting the APU against overload; available power falls with altitude.
Chapter 26 · APU and Engine Starting
7
e-books by eatpl.in · © 2026 · Do not copy or distribute
Here are the conditions that typically make the A P U shut itself down. A fire in the A P U compartment shuts it down immediately, and on many aircraft, especially on the ground, the extinguisher bottle is fired automatically if the fire persists. An overspeed shuts it down, because a free-running rotor could burst. So does a turbine over-temperature, a high exhaust gas temperature, which also protects the unit from being overloaded, since its power falls with altitude. Low oil pressure and high oil temperature shut it down to save the bearings. And there are other malfunctions, such as a failure to accelerate or the loss of a control signal. In the exam, look for overspeed, turbine over-temperature, low oil pressure, high oil temperature and fire.
Part 2 · Operation
When the APU is used On the ground Electrics and air conditioning at the gate; air for engine starts ; normally running during start and taxi .
In flight Back-up after an engine or generator failure; ETOPS needs it available. Often selected before landing .
Starting it Electric starter powered from the aircraft’s battery . May not power everything, but enough to operate safely.
Chapter 26 · APU and Engine Starting
8
e-books by eatpl.in · © 2026 · Do not copy or distribute
When is the A P U actually used? On the ground it runs at the gate for electrics and air conditioning, supplies the air to start the main engines, and normally keeps running during start-up and taxi. In flight it is a back-up source of power after the failure of a main engine or generator, and for E T O P S operations it must be available. It is also commonly started before landing, so that power is on hand if something fails late in the flight. It starts from its own electric starter powered by the aircraft battery. The A P U may not be able to power every system at once, but it provides enough services for the aircraft to be operated safely.
Part 3 · Emergency power
The ram air turbine A turbine driven by the airflow from the aircraft’s forward speed Extended into the airflow, or mounted inside with ram air ducted to it Fail-safe : deploys automatically if power is lostDrives a gearbox with a hydraulic pump for the flying controls And / or an emergency generator for essential electrics airflow from forward speed Ram air turbine deploys automatically if power is lost (fail-safe) Gearbox drives a hydraulic pump for the flying controls and / or an emergency generator
Chapter 26 · APU and Engine Starting
9
e-books by eatpl.in · © 2026 · Do not copy or distribute
In addition to the A P U, some aircraft carry a ram air turbine, or RAT, for emergencies. It is a small turbine, usually with two blades, turned by the airflow that comes from the aircraft’s forward speed. Most often it swings out from the fuselage or wing into the airstream; on some designs it stays inside and ram air is ducted onto it through a control valve. The design is fail-safe: if the aircraft loses power, the RAT deploys and runs automatically. Its turbine drives a gearbox, on which can be fitted a hydraulic pump, a generator, or both. These power the flying controls, the elevator, rudder and ailerons, and the essential electrical supplies, so the crew can keep control and land.
Part 4 · Starting
What every start needs 1 Rotation turn the rotor to draw air in 2 Fuel into the combustion chambers 3 Ignition to light the mixture plus: motoring with no ignition (blow-out), and ignition independent of the start cycle The three basics Turn the compressor and turbine to get air through, supply fuel , and provide ignition .
Motoring (blow-out) Turn the engine with no fuel and no ignition : to dry out a wet start or cool a hot start.
Ignition alone Igniters usable independently of the start cycle : relights and continuous ignition.
Chapter 26 · APU and Engine Starting
10
e-books by eatpl.in · © 2026 · Do not copy or distribute
To start a gas turbine there are three basic requirements. First, the compressor and turbine assembly must be turned, so that air is drawn through into the combustion chambers. Second, fuel must be supplied to the combustion chambers. Third, ignition must be provided to start the fuel and air mixture burning. On top of those, a starting system needs two more facilities. It must be able to motor the engine over with no ignition and no fuel, which is called a blow-out or motoring cycle. That is used after a failed start, a wet start, to dry the engine out, or after a hot start, to cool it down. And the igniters must be usable independently of the start cycle, for relights and for continuous ignition.
Part 4 · Starters
Starter motors and their duty cycle Most common on civil aircraft: the air starter and the electric starter The starter turns the HP spool (in a multi-spool engine) through the gearbox Every starter has a duty cycle : a time limit for running Then a cooling period before it may be used again Air starters on large turbofans may allow about 3 to 5 minutes The starter drive and its duty cycle Starter Gearbox Radial shaft HP spool (N2) LP spool follows once gas reaches its turbine
0
2
4
6
8
10
Minutes energised (limit) cooling period Example figures only: each starter has its own duty cycle; air starters on large turbofans may run about 3 to 5 minutes, covering a start attempt and any motoring that follows.
Chapter 26 · APU and Engine Starting
11
e-books by eatpl.in · © 2026 · Do not copy or distribute
The two most common ways of turning a modern civil engine for a start are the air starter motor and the electric starter motor. Either way, the starter drives the high pressure spool, through the accessory gearbox. In a multi-spool engine it is always the H P spool that is turned; the L P spool follows once gas flows through its turbine. Every starter has a duty cycle, the length of time it may be energised before it must stop. That may be followed by a cooling period before it can be used again, because the starter heats up quickly under such a heavy load. On large turbofans the air starter’s duty cycle might be three to five minutes, which has to cover a start attempt and any motoring that follows.
Part 4 · Air starter
The air starter motor The most popular system: light, simple and economical Uses low pressure, high volume air Air through an electrically controlled start valve spins a small turbine , then exhausts The turbine drives a reduction gear and, through a sprag clutch , the engine Mounted on the accessory gearbox Air starter motor low pressure air start valve (electrically controlled) turbine exhaust reduction gear sprag clutch to gearbox Light, simple and economical; runs on low pressure, high volume air from the APU, a ground unit, or a running engine (cross-bleed), in that order of preference.
Chapter 26 · APU and Engine Starting
12
e-books by eatpl.in · © 2026 · Do not copy or distribute
The air starter motor is probably the most popular starting system in use today, because it is light, simple and economical. It runs on low pressure, high volume air. The air passes through an electrically controlled start valve; watch it open. The air then spins a small, fast turbine and is exhausted overboard. The turbine drives a reduction gear, which trades speed for torque, and the output turns the engine through a sprag clutch, a one-way clutch we look at shortly. The whole unit is bolted to the accessory gearbox, so the drive goes through the gearbox and the radial shaft to the H P spool. Because the air turbine is so small and light, an air starter gives a lot of power for very little weight.
Part 4 · Starting air
Where the starting air comes from Sources in order of preference: the APU , a ground power (air) unit , a cross-bleed start Cross-bleed: air from an engine that is already running The normal bleed ducts are used backwards to reach the starter Non-return valves stop the air flowing into the engine compressorMonitor duct pressure and the start valve light Starting air on a twin APU Engine 1 running Engine 2 starting HP / non-return valve ducts used backwards start valve Ground air cart: connection into the same duct Preference: APU, then ground unit, then cross-bleed.
Chapter 26 · APU and Engine Starting
13
e-books by eatpl.in · © 2026 · Do not copy or distribute
Where does the air for the air starter come from? In order of preference: first the aircraft’s own A P U; second a ground air unit, often called an air cart; and third a cross-bleed start, using air bled from an engine that is already running. In every case the air reaches the starter through the normal bleed air ducting, simply used backwards. The air must not escape forwards into the compressor of the engine being started, so there is a non-return valve at the L P bleed outlet and a non-return facility in the H P shut-off valve. During the start you keep an eye on the duct pressure, to be sure there is enough air, and on the start valve light, which tells you whether the valve is open.
Part 4 · Disengaging
The sprag clutch and the cut-out A sprag clutch drives one way only: starter to engine As the engine accelerates past the starter it free-wheels and disengages It stops the engine driving the starter, which could burst by centrifugal force The start valve closes at a set speed above self-sustaining A flyweight cut-out switch may de-energise the start valve automatically Sprag (one-way) clutch starter side engine side (outer race) Starter faster: sprags wedge, drive Engine faster: sprags tilt, free-wheel (overrun) Stops the engine driving the starter after start: an over-sped starter turbine could burst from centrifugal force.
Chapter 26 · APU and Engine Starting
14
e-books by eatpl.in · © 2026 · Do not copy or distribute
How does the starter let go? Between the starter and the engine is a sprag clutch, a one-way clutch. Its sprags are small tilted wedges between two rings. When the starter turns faster than the engine, they jam and transmit the drive. When the engine overtakes the starter, they tilt the other way and free-wheel. This matters, because if the running engine drove the starter, the little starter turbine would be spun far beyond its design speed and could break up from centrifugal force. At a set engine speed, a little above self-sustaining speed, the start valve is closed and the starter runs down. Often a flyweight cut-out switch does this automatically, removing the electrical supply that holds the start valve open.
Part 4 · Electric starters
Electric starters and starter-generators The original method; still used on small jets and helicopters Out of favour on large engines because of its weight Starter-generator : one unit, motor then generator; better usefulness for its weightPawl-and-ratchet clutch: limits starting torque , over-runs , disengages Crash re-engagement : re-energising before the spool has slowed enoughElectric starter and starter-generator Electric starter original method; now small jets, helicopters Starter-generator permanently engaged: motor to start, then generator The pawl-and-ratchet clutch of an electric starter: 1 limits excessive starting torque on the engine 2 over-runs as the engine accelerates to idle 3 disengages the starter from the engine Crash re-engagement re-energising the starter before the spool has slowed enough for the clutch to engage itself
Chapter 26 · APU and Engine Starting
15
e-books by eatpl.in · © 2026 · Do not copy or distribute
The electric starter motor was the original way of starting a gas turbine, and it is still used on smaller executive jets and helicopters. It has fallen out of favour on large engines because a motor powerful enough would be too heavy. Increasingly popular on smaller engines is the starter-generator, which works as a motor for the start and then as a generator, so its dual purpose gives more usefulness for its weight. Unlike a plain starter, it stays permanently engaged with the gearbox, and its control circuits are more complex. A plain electric starter has a pawl-and-ratchet clutch with three jobs: it limits excessive starting torque, it over-runs as the engine accelerates, and it disengages the starter. Beware crash re-engagement: energising the starter again before the spool has slowed down enough for the clutch to engage cleanly.
Part 5 · Normal start
A normal start on the EGT and N2 gauges
0
10
20
30
40
50
60
0
20
40
60
80
100
Time from start selection (s)
N2 %
EGT °C
0
200
400
600
800
1000
EGT limit
self-sustaining ≈ 30% N2
fuel + ignition
light-up
EGT peak
starter cut-out
idle
Normal start: N2 and EGT 1 Starter accelerates N2; no fuel yet 2 Fuel and ignition at the stated N2 3 Light-up: sharp EGT rise, then it steadies 4 FCU adds fuel: second EGT rise 5 Past self-sustaining (~30% N2) 6 Starter and igniters cut out a little later 7 EGT peaks just before idle, then settles Idle ≈ 60% N2 and 25% N1
Chapter 26 · APU and Engine Starting
16
e-books by eatpl.in · © 2026 · Do not copy or distribute
Here is a normal start of a two-spool turbofan, read on the two gauges that matter most: exhaust gas temperature, and H P compressor speed, N two. On start selection, the starter turns the engine with no fuel and no ignition, pushing air through the combustors. At the speed stated for that engine, fuel and ignition are switched on. Light-up must follow within a set time, typically about twenty seconds, and it shows as a sharp rise in E G T, because there is excess fuel in the chambers. Once that is burnt off, the rise steadies. As the engine accelerates, the fuel control adds fuel and the mixture runs rich, giving a second steep rise. The engine passes self-sustaining speed, the starter cuts out a little later, E G T peaks just before idle and settles.
Part 5 · Watching the start
What to watch, and the key numbers Most attention: EGT and N2 ; also fuel flow, N1, duct pressure, start valve light Self-sustaining speed : about 30% N2 ; the engine can accelerate without the starterStarter kept on a little longer , then cut out with the igniters by a speed switch EGT peaks just before idle , then falls to idle EGTIdle: about 60% N2 and 25% N1 ; keep a hand on the fuel switch until stable
0
10
20
30
40
50
60
0
20
40
60
80
100
Time from start selection (s)
N2 %
EGT °C
0
200
400
600
800
1000
EGT limit
self-sustaining ≈ 30% N2
light-up
peak
Normal start Dotted grey: EGT in a normal start
Chapter 26 · APU and Engine Starting
17
e-books by eatpl.in · © 2026 · Do not copy or distribute
During a start the two instruments that need the most attention are the exhaust gas temperature and N two, the H P speed. Watch them together; also check fuel flow, N one, duct pressure and the start valve light. Watch the gauges now: the starter drives the speed up, the engine lights and the temperature rises. Self-sustaining speed, about thirty per cent N two, is the speed from which the engine can accelerate to idle without the starter. But the starter is not cut out there; it keeps helping a little longer, so that the engine reaches idle smoothly, and then a speed switch cancels starter and igniters. The temperature peaks just before idle, then settles. Idle is roughly sixty per cent N two and twenty five per cent N one. Keep a hand on the fuel switch until everything is stable.
Part 6 · Faults
The hot start EGT rises normally at first, then races towards the limit Cause: too much fuel, not enough air to cool the gas through the turbine e.g. throttle not at idle, engine turning too slowly , partial seizure by ice, tailwind , residual heat Action: shut off fuel at once (HP cock / fuel switch), then motor to cool Exceed the limit by even one degree : the engine is unserviceable
0
10
20
30
40
50
60
0
20
40
60
80
100
Time from start selection (s)
N2 %
EGT °C
0
200
400
600
800
1000
EGT limit
self-sustaining ≈ 30% N2
over the limit
Hot start Dotted grey: EGT in a normal start
Chapter 26 · APU and Engine Starting
18
e-books by eatpl.in · © 2026 · Do not copy or distribute
In a hot start, the exhaust gas temperature begins to rise quite normally, so you can only spot the problem by comparing with a normal start. A few seconds in, the temperature keeps racing upwards towards the limit. Watch the gauge: it looks normal at first, then goes through the limit. The cause is almost always too much fuel and not enough air to cool the gas passing through the turbine. That can come from the throttle not being at idle, the engine turning too slowly, partial seizure by ice, or very commonly a tailwind on the second start of the day, with heat left in the engine. Your only chance is to cut the fuel at once with your hand already on the switch, then motor the engine to cool it. Exceed the limit by one degree and the engine is unserviceable.
Part 6 · Faults
The wet start: no light-up No rise in EGT ; N2 stabilises at the most the starter can giveFuel flow is indicated: fuel is being pumped into a cold engineDanger: the fuel later ignites as a long flame from the exhaust: torching Action: close the HP fuel cock and switch off ignition, but keep the starter turning This blow-out (motoring) cycle clears the fuel before another attempt
0
10
20
30
40
50
60
0
20
40
60
80
100
Time from start selection (s)
N2 %
EGT °C
0
200
400
600
800
1000
EGT limit
self-sustaining ≈ 30% N2
starter maximum
Wet start Dotted grey: EGT in a normal start
Chapter 26 · APU and Engine Starting
19
e-books by eatpl.in · © 2026 · Do not copy or distribute
A wet start is a failure to light up. The signs are that the exhaust gas temperature does not rise at all, and the r p m settles at the most the starter alone can achieve. Meanwhile the fuel flow meter shows that fuel is being delivered, so the engine is soaking up fuel. Starting faults are rare and always come as a surprise, so it can take a while to realise, and the longer it goes on, the wetter the engine. If that fuel is ignited later, a huge flame shoots out of the exhaust, which is called torching. So do not abandon the start cycle: close the H P fuel cock and switch off the ignition, but keep the starter turning the compressor for a specified time. That is the blow-out or motoring cycle, and it must be within the starter duty cycle.
Part 6 · Faults
The hung start The engine lights up but stops accelerating below self-sustaining speed (so below idle) RPM hangs; EGT is higher than expected for that RPM , though below the limit Cause: not enough air for efficient combustion (e.g. contaminated compressor) Or too little starter help : starter disengaging too soon, weak starter, flat battery Action: close the HP cock and investigate
0
10
20
30
40
50
60
0
20
40
60
80
100
Time from start selection (s)
N2 %
EGT °C
0
200
400
600
800
1000
EGT limit
self-sustaining ≈ 30% N2
rpm hangs
Hung start Dotted grey: EGT in a normal start
Chapter 26 · APU and Engine Starting
20
e-books by eatpl.in · © 2026 · Do not copy or distribute
In a hung start, the engine lights up normally but then fails to accelerate. It stagnates at an r p m below self-sustaining speed, and so well below idle. Watch the gauges: it lights, and then the speed stagnates. The exhaust gas temperature is higher than you would expect for that r p m, although it is not over the limit. Leaving the engine there does it no good at all and could do a lot of harm, so close the H P cock and investigate. The usual cause is not enough airflow through the engine for efficient combustion, for example a contaminated compressor, so the gas cannot help the starter accelerate the engine. A similar result comes from too little starter assistance: a starter that disengages too soon, a weak starter or a flat battery.
Part 6 · Side by side
Hot, wet and hung starts compared Hot start Wet start Hung start EGT Rises fast, towards or over the limit No rise High for the RPM , below the limitN2 Slow acceleration Stays at starter maximum Hangs below self-sustaining Fuel flow High for the airflow Indicated, with no light-up About idle flow Usual cause Too much fuel, too little air No ignition (e.g. igniter fault) Too little air or starter help Action Fuel off at once , motor to coolHP cock shut, ignition off, keep motoring Close HP cock , investigate
Typical exam pairing for a hung start: high EGT, idle fuel flow, low RPM .
Chapter 26 · APU and Engine Starting
21
e-books by eatpl.in · © 2026 · Do not copy or distribute
Let us set the three faults side by side. In a hot start the temperature rises fast towards or past the limit while the engine accelerates slowly; there is too much fuel for the air, and you cut the fuel at once and motor to cool. In a wet start there is no temperature rise at all and N two stays at the starter maximum while fuel flow is indicated; the usual cause is no ignition, and you shut the H P cock, switch off ignition and keep motoring to blow out the fuel. In a hung start the temperature is high for the r p m, but below the limit, and the r p m hangs below self-sustaining speed with about idle fuel flow; you close the H P cock and investigate. The exam pairing for a hung start is high E G T, idle fuel flow, low r p m.
Part 7 · Relight and blow-out
Blow-out cycle and in-flight relight Blow-out (motoring) cycle : starter on, no fuel, no ignition Clears fuel after an unsuccessful start, to prevent torching Must fit within the starter duty cycle (air starters: about 3–5 min) Relight : fuel and ignition without the starter ; a windmilling air startSuccess shows as a rise in EGT or RPM
0
10
20
30
40
50
60
0
20
40
60
80
100
Time from start selection (s)
N2 %
EGT °C
0
200
400
600
800
1000
EGT limit
self-sustaining ≈ 30% N2
starter on, no fuel, no ignition
After a wet start: motor Dotted grey: EGT in a normal start
Chapter 26 · APU and Engine Starting
22
e-books by eatpl.in · © 2026 · Do not copy or distribute
Two related procedures. The blow-out, or motoring, cycle turns the engine with the starter but with no fuel and no ignition. It is used when fuel has been put into an engine during an unsuccessful start, to blow it out or let it evaporate before another attempt, so that it cannot torch. On most modern turbofans the air starter duty cycle is about three to five minutes, and the motoring must fit within it. The relight is the opposite combination: fuel and ignition without the starter. After a flame-out in flight, the engine is windmilling in the airflow, so selecting fuel and ignition can achieve a windmilling air start. You know it has worked when either the exhaust gas temperature or the r p m starts to rise.
Part 7 · Stopping
Shutdown, tailpipe fires and rundown time A jet engine is normally shut down by closing the HP fuel cock Rundown (spool-down) time : from HP cock closed to the engine stoppingNote it for each engine: a shorter rundown can warn of rubbing or bearing trouble Fire in the jet pipe during start: HP cock closed , keep motoring to blow it out The LP cock is a firewall isolation valve, not the normal shutdown control Rundown after the HP cock closes
0
20
40
60
80
0
20
40
60
Time after HP cock closed (s)
N2 (%) normal engine stops much sooner: investigate Shut down with the HP cock; note each engine’s rundown time A shorter time can mean rubbing or bearing trouble
Chapter 26 · APU and Engine Starting
23
e-books by eatpl.in · © 2026 · Do not copy or distribute
How is a jet engine stopped? Normally by closing the H P fuel cock, which cuts the fuel to the burners. The L P cock is an isolation valve at the firewall and is not the normal way to stop the engine. Once the H P cock is closed, the engine runs down. The time it takes to stop is called the rundown or spool-down time. Make a mental note of it for each engine and compare: an engine that stops noticeably quicker than usual may have rubbing or bearing trouble. One more case: if the ground crew report a fire in the jet pipe during start, typically burning fuel left after a wet start, close the H P cock but keep the starter motoring the engine, so the airflow blows the fire out and cools the turbine.
Exam traps
Points examiners like to test APU Electrical, pneumatic (and hydraulic) power, ground and air . Started from the battery .
Auto shutdown Overspeed, turbine over-temperature, low oil pressure, high oil temperature, fire .
Air starter Light, simple, economical; low pressure, high volume ; air usually from the APU .
Starter Drives the HP spool ; disengaged just above self-sustaining speed.
Numbers Self-sustaining ≈ 30% N2 ; idle ≈ 60% N2, 25% N1 ; EGT peaks just before idle .
Faults Hung: high EGT, idle fuel flow, low RPM . Failed light-up: motor with HP cock shut, no igniters .
Chapter 26 · APU and Engine Starting
24
e-books by eatpl.in · © 2026 · Do not copy or distribute
Here are the exam favourites. The A P U provides electrical, pneumatic and, directly or indirectly, hydraulic power, on the ground and in the air, and it is started from the aircraft battery. Automatic shutdown follows overspeed, turbine over-temperature, low oil pressure, high oil temperature and fire. The air starter is light, simple and economical, uses low pressure, high volume air, and usually takes it from the A P U. The starter drives the H P spool and is disengaged just above self-sustaining speed, not as soon as the engine lights. Self-sustaining speed is about thirty per cent N two, idle about sixty per cent N two and twenty five per cent N one, and E G T peaks just before idle. A hung start shows high E G T, idle fuel flow and low r p m. After a failed light-up, motor the engine with the H P cock shut and no igniters.
Summary
APU and engine starting in one page APU Free turbine turboshaft (~600 hp), tail cone; constant speed, no CSD; load compressor for bleed.
APU use Ground and air; ETOPS back-up; battery start; few controls; auto shutdown for fire and limits.
RAT Airflow-driven turbine; auto deploy; hydraulic pump for controls and/or emergency generator.
Starters Air (light, LP high-volume air: APU > ground unit > cross-bleed) or electric; duty cycle.
Clutches Sprag clutch free-wheels; cut-out above self-sustaining; beware crash re-engagement.
Normal start Fuel + ignition at set N2; light-up ≤ ~20 s; SSS ~30% N2; EGT peak before idle; idle 60/25%.
Faults Hot: fuel off now. Wet: HP cock shut, keep motoring. Hung: high EGT, low RPM; close HP cock.
Stopping Shut down with the HP cock; compare rundown times; relight = fuel + ignition, no starter.
Chapter 26 · APU and Engine Starting
25
e-books by eatpl.in · © 2026 · Do not copy or distribute
Let us pull it together. The A P U is usually a free turbine turboshaft of about six hundred horsepower in the tail cone. Its free turbine runs at constant speed, so its generator needs no constant-speed drive, and a load compressor supplies bleed air. It runs on the ground and in the air, starts from the battery, and shuts itself down for fire and exceeded limits. The RAT gives emergency hydraulic and electrical power from the airflow. Air starters use low pressure, high volume air from the A P U, a ground unit or a cross-bleed; electric starters suit smaller engines. A sprag clutch lets go above self-sustaining speed. In a normal start, light-up comes within about twenty seconds, self-sustaining is about thirty per cent N two, and E G T peaks just before idle. Know the hot, wet and hung start actions, and shut down with the H P cock.