Engines · Chapter 28
Turbine Engine Fuel Systems How fuel gets from the tank to the spray nozzles: pumps, heaters, filters, the fuel control unit and its limiters, shut-off valves, nozzles and electronic engine control.
TANK
LP pump
FCOC
Filter
HP pump
FCU
HP cock
atomised spray
low pressure: yellow
high pressure: orange
© 2026 eatpl.in. For the personal study of eatpl.in students only. Do not copy or distribute.
e-books by eatpl.in · © 2026 · Do not copy or distribute
Chapter twenty-eight follows the fuel through a gas turbine engine, from the tank to the flame. On the way it is pumped twice, warmed, filtered and measured, and then the fuel control unit decides exactly how much reaches the burners, protecting the engine against surge, flame-out, over-temperature, over-pressure and over-speed. We finish with the valves that start and stop the engine, the spray nozzles, the drains, and the electronic engine controls that do most of this on modern aircraft.
Roadmap
From the tank to the flame The engine fuel system filters, warms, pressurises, meters and monitors the fuel, and delivers it to the spray nozzles at the rate the throttle demands.
1 · Supply Booster pumps, LP valve , LP pump , tank venting and boiling at altitude.
2 · Conditioning Fuel-cooled oil cooler , fuel heater , LP filter and warnings.
3 · Pressure and control HP pumps and the fuel control unit : altitude, acceleration, EGT, pressure and RPM limits.
4 · Delivery and electronics HP cock , duplex nozzles , dump valve, drains tank , flowmeter , EEC and FADEC .
Chapter 28 · Turbine Engine Fuel Systems
2
e-books by eatpl.in · © 2026 · Do not copy or distribute
In this lesson we follow the fuel from the tank to the flame. The engine fuel system has to filter the fuel, warm it, raise its pressure, meter exactly the right amount and monitor it, and then deliver it to the spray nozzles at the rate the throttle demands. Part one is the supply: booster pumps, the LP valve, the LP pump, and why tanks are vented and fuel can boil at altitude. Part two is conditioning: the fuel-cooled oil cooler, the fuel heater and the low pressure filter. Part three is the heart of the system: the high pressure pumps and the fuel control unit, with its altitude, acceleration, temperature, pressure and RPM controls. Part four covers delivery and electronics: the HP cock, the duplex nozzles and dump valve, the drains tank, the flowmeter, and electronic engine control including FADEC.
Part 1 · The whole system
The engine fuel system at a glance AIRFRAME ENGINE FUEL SYSTEM Fuel tank booster pumps LP valve fire handle LP pump N1-driven FCOC oil cooler Heater HP air LP filter HP pump N2-driven FCU meters fuel HP cock start / stop Flow meter Spray nozzles Drains tank on shutdown throttle P1 N1 / N2 P3 EGT FCU inputs fuel pressure and temperature sensed here low pressure fuel high pressure fuel
Chapter 28 · Turbine Engine Fuel Systems
3
e-books by eatpl.in · © 2026 · Do not copy or distribute
Here is the whole system before we take it apart. Fuel starts in the airframe: the booster pumps in the tank push it through non-return valves to the LP valve, which the fire handle can close. Inside the engine, the gearbox-driven LP pump passes it to the fuel-cooled oil cooler and the fuel heater, where it is warmed, and then to the low pressure filter. Fuel pressure and temperature are sensed about here. The HP pump, driven from the HP spool, raises the pressure enormously, shown in red. The fuel control unit meters the flow, using the throttle position and engine signals: intake pressure, spool speeds, compressor delivery pressure and exhaust gas temperature. Then the HP cock, the flowmeter, and finally the spray nozzles. On shutdown, fuel left in the manifold goes to a drains tank. Learn this order: exam questions often ask where a component sits.
Part 1 · Supply
From the airframe to the engine Booster pumps in the tanks push fuel through non-return valves to the engineThe LP (pylon) shut-off valve isolates the engine from the airframe fuel Closed for component removal and by the fire handle on a fire warning It can stop the engine in an emergency, but the engine runs down more slowly A crossfeed valve lets any tank feed any engine Wing tank booster pumps Crossfeed valve to other side NRV LP (pylon) shut-off valve Engine LP pump ENG FIRE handle pulled: LP valve shuts Closes for component removal, an engine fire, or (slowly) as an emergency stop
Chapter 28 · Turbine Engine Fuel Systems
4
e-books by eatpl.in · © 2026 · Do not copy or distribute
The supply starts in the airframe fuel system. Booster pumps in the tanks push fuel through non-return valves to the engine fuel shut-off valve, often called the LP valve or pylon valve. Its job is to isolate the engine from the airframe fuel. Engineers close it when they remove an engine component, and it is closed automatically when the crew pulls the fire handle after an engine fire warning, so that no more fuel can feed the fire. Watch the scene: the fire warning lights, the handle is pulled, the valve shuts and the flow stops. The LP valve can also be used to stop the engine in an emergency, but the engine will take longer to run down, because it keeps burning the fuel already in its pipes, and runs slowly short of fuel. A crossfeed valve allows any tank to feed any engine.
Part 1 · Supply
The LP (backing) pump First pump in the engine fuel system ; usually a centrifugal pump, driven by the engine gearbox Supplies the HP pump with fuel at a positive inlet pressure , preventing cavitation If the tank booster pumps all fail , the LP pump sucks fuel from the tank and the engine keeps running At high altitude, suction plus a low boiling point means cavitation and vapour So the MEL may require a reduced cruising altitude Centrifugal LP (backing) pump to HP pump fuel enters at the eye, flung outwards driven from the gearbox Booster pumps failed at FL420? Fuel surface pressure only 170 hPa: low boiling point the LP pump must suck: cavitation and vapour MEL may require a lower cruising level
Chapter 28 · Turbine Engine Fuel Systems
5
e-books by eatpl.in · © 2026 · Do not copy or distribute
Once inside the engine fuel system, the fuel reaches the low pressure pump, also called the backing pump. It is usually a centrifugal pump, driven by the engine gearbox, and its job is to feed the HP pump with fuel at a positive pressure, so that the HP pump never runs short and never cavitates. If all the tank booster pumps fail, the LP pump can suck fuel up from the tank by itself, so the engine keeps running. But think about flight level four two zero. The pressure on the fuel surface is only about one hundred and seventy hectopascals, so the boiling point of the fuel is low, and on top of that the pump is now sucking, which lowers the pressure in the line even further. The fuel may boil and the pump may cavitate. That is why the minimum equipment list may require a lower cruising altitude with booster pumps inoperative.
Part 1 · Supply
Tank venting and boiling at altitude The boiling point of fuel falls as altitude increases, because the pressure on it falls Tanks are vented to the outside air so they neither burst nor collapse On jet transports the vents are fed by ram air from a flush scoop This keeps a small positive pressure on the fuel: less boiling and less pump cavitation Tanks are not pressurised with compressor or air-conditioning air Ram air on the fuel surface ram air into the vent scoop small positive pressure on the fuel surface fuel As the aircraft climbs pressure falls → boiling point of the fuel falls ram-air venting keeps tank pressure slightly above ambient → less boiling, less vapour, less pump cavitation
Chapter 28 · Turbine Engine Fuel Systems
6
e-books by eatpl.in · © 2026 · Do not copy or distribute
The fuel tanks must breathe. As fuel is used, and as the aircraft climbs and descends, air must flow in and out through the vent system so the tanks neither burst nor collapse. Remember from the fuels lesson that the boiling point of the fuel falls as the aircraft climbs, because the pressure on the fuel surface is lower. On jet transports, the vent system is fed by ram air from a flush scoop under the wing. The forward speed of the aircraft pushes air into the vent, so the tank is kept at a small positive pressure above the outside air. That extra pressure on the fuel surface reduces boiling and vapour, and helps prevent cavitation at the pumps. In the exam, the tanks are pressurised by ram air to prevent cavitation, not by air from the engine compressor or the air conditioning.
Part 2 · Conditioning
The fuel-cooled oil cooler Fitted on the majority of gas turbines, on the LP side after the LP pump A double job: it cools the oil and heats the fuel Warm fuel: no ice crystals to block the filter and components downstream The oil pressure is kept higher than the fuel pressure So any internal leak sends oil into the fuel , where it is simply burned Fuel-cooled oil cooler (matrix) cold fuel warm fuel hot oil in cooled oil out Oil pressure is kept higher than fuel pressure a leak sends oil into the fuel, never fuel into the oil
Chapter 28 · Turbine Engine Fuel Systems
7
e-books by eatpl.in · © 2026 · Do not copy or distribute
The fuel-cooled oil cooler is fitted on the majority of gas turbines, on the low pressure side just after the LP pump. Inside, hot engine oil flows through a matrix of tubes, and the fuel flows around them. So it does two jobs at once: it cools the oil, and it heats the fuel, which melts any ice crystals that would otherwise block the filter and the components further downstream. Here is an important design point: the oil pressure in the cooler is kept higher than the fuel pressure. Why? If a tube cracks, the leak then goes from oil into fuel. A little oil in the fuel is simply burned in the combustor. The other way round, fuel leaking into the oil would thin it, ruin its lubrication and could start a fire in the bearing chambers.
Part 2 · Conditioning
The fuel heater Next after the FCOC; it completes the warming of the fuel Heated by compressor delivery air (HP compressor bleed) Removes any remaining ice crystals , and helps prevent waxing Automatic , working with the FCOC to hold a set fuel temperature, or manual , selected by the flight engineerWarning: overheating the fuel would cause vapour, so heat is controlled Air-fuel heater with temperature control from FCOC to LP filter valve compressor delivery air overboard temp sensor automatic, or manual on older types
Chapter 28 · Turbine Engine Fuel Systems
8
e-books by eatpl.in · © 2026 · Do not copy or distribute
The next component is the fuel heater, which completes the warming of the fuel. It is a heat exchanger warmed by compressor delivery air, hot air bled from the high pressure compressor, so in the exam, fuel is heated by air from the compressor. Its job is to remove any ice crystals that the oil cooler has not dealt with, and warm fuel also helps prevent waxing, which is the answer the exam usually wants to the question why fuel is heated. On modern engines the heater is automatic: a temperature sensor downstream opens the air valve as needed, working with the oil cooler to hold a set fuel temperature. On older aircraft it was selected manually by the flight engineer, usually for a set time. Heat must be controlled, because fuel that is too hot would vaporise in the HP pump and fuel control unit.
Part 2 · Conditioning
The LP fuel filter On the low pressure side , after the heater Protects the delicate parts of the HP pump and the FCU from dirt and contamination A differential pressure switch warns of a blocking element: filter caution A bypass (relief) valve then lets unfiltered fuel round the element so the engine keeps running Blockage can come from ice crystals, wax or microbial debris LP filter with bypass and warning from heater to HP pump relief bypass opens if the element blocks ΔP FUEL FILTER caution before the bypass Protects the HP pump and FCU; sits on the low pressure side
Chapter 28 · Turbine Engine Fuel Systems
9
e-books by eatpl.in · © 2026 · Do not copy or distribute
After the heater comes the fuel filter. It sits on the low pressure side of the system, and its job is to protect the delicate, finely machined parts inside the HP pump and the fuel control unit from dirt and contamination. Things that can block it include dirt, ice crystals, wax and the debris of microbial growth. A differential pressure switch measures the pressure drop across the element. Watch the scene: as the element starts blocking, the pressure drop rises and the flow to the HP pump falls. When the drop reaches a set value, the switch lights a fuel filter caution on the flight deck. If the blockage continues, a relief valve opens, and the bypass lets unfiltered fuel go round the element, so the engine keeps running rather than flaming out. The caution comes before the bypass opens, giving the crew warning.
Part 2 · Monitoring
Pressure, temperature and the flowmeter Fuel pressure and temperature are sensed and shown to the pilot to monitor the systemThe flowmeter sits between the HP shut-off valve and the spray nozzles It shows the instantaneous flow in kg/h (or gallons per hour) A totaliser sums the fuel used since engine start Fuel used plus fuel remaining should equal the fuel at start: a mismatch suggests a leak Fuel flow and fuel used FF 2 400 kg/h FU 8 400 kg instantaneous flow totaliser (since start) Worked example: leak check 2 engines × 2 400 kg/h × 3.5 h = 16 800 kg used Fuel on board at start: 20 000 kg Expected now: 20 000 − 16 800 = 3 200 kg Gauges show: 2 400 kg Discrepancy: 800 kg not through the meters → suspect a leak upstream of the flowmeter
Chapter 28 · Turbine Engine Fuel Systems
10
e-books by eatpl.in · © 2026 · Do not copy or distribute
Fuel pressure and temperature are sensed in the low pressure part of the system and shown to the pilot, so the system can be monitored. The fuel flowmeter is the one to remember for the exam: it sits between the HP shut-off valve and the spray nozzles, so it measures exactly the fuel the engine burns. It shows the instantaneous flow, in kilograms per hour or gallons per hour, and a totaliser adds up the fuel used since the engine was started. Here is a practical use. Two engines burning two thousand four hundred kilograms per hour each for three and a half hours use sixteen thousand eight hundred kilograms. If you started with twenty thousand, three thousand two hundred should remain. If the gauges show only two thousand four hundred, eight hundred kilograms has gone without passing the flowmeters, and you should suspect a fuel leak.
Part 3 · High pressure
The HP fuel pump Driven by the HP shaft through the HP (accessory) gearbox: on a high-bypass engine, the HP compressor spool Raises the pressure and flow needed for the thrust demanded High pressure is what atomises the fuel at the burners Types: axial piston (swash plate) , variable delivery; or spur gear , fixed delivery with spill Lubricated by the fuel itself : it needs fuel flow and lubricity Why such high pressure? HP pump N2 via gearbox fine mist: fast, clean burning spray nozzle Pressure is what atomises the fuel at the nozzle Small droplets: large surface area, quick evaporation Low pressure: big drops, poor combustion, smoke, deposits The pump must also meet the flow for any thrust demanded
Chapter 28 · Turbine Engine Fuel Systems
11
e-books by eatpl.in · © 2026 · Do not copy or distribute
The high pressure pump is driven by the engine high pressure shaft through the accessory gearbox. On a high-bypass engine that means it is driven by the HP compressor spool, not by the fan or the LP compressor. The HP spool is chosen because it is turning whenever the engine is running, including during the start, when the fan is barely moving. The pump raises the pressure and flow to whatever the thrust setting demands. Why so much pressure? Because pressure is what atomises the fuel at the burners: forced through a small nozzle it breaks up into a fine mist of tiny droplets, with a huge surface area, so they evaporate and burn quickly and cleanly. There are two main types, the axial piston pump and the spur gear pump. Both are lubricated by the fuel passing through them.
Part 3 · High pressure
The axial piston (swash plate) pump Axial piston (swash plate) pump drive (N2) swash plate (tilted) rotating cylinder block out in More tilt = longer stroke = more fuel per turn A servo piston sets the angle: variable delivery 0 5 10 15 0 20 40 60 80 Swash plate angle (°) delivery (L/min) Worked example Pump 7 plungers, 12 mm bore Stroke at 12° 60 mm × tan 12° = 12.8 mm Per turn ≈ 10.1 cm³ At 6000 rpm ≈ 61 L/min That is ≈ 2 900 kg/h of fuel A variable delivery pump, as used in constant pressure systems; its moving parts are lubricated by the fuel passing through.
Chapter 28 · Turbine Engine Fuel Systems
12
e-books by eatpl.in · © 2026 · Do not copy or distribute
The axial piston pump is the classic HP fuel pump. The drive turns a cylinder block containing several plungers. Their ends bear on a swash plate, a plate set at an angle to the drive shaft. As the block turns, each plunger is pushed in and out once per turn, drawing fuel in and forcing it out. The tilt of the swash plate sets the stroke: more tilt, longer stroke, more fuel per turn. A servo piston changes the angle, so the pump is variable delivery: it can hold a set pressure while supplying just the flow needed, like a constant pressure hydraulic pump. In the worked example, seven twelve-millimetre plungers at twelve degrees give about ten cubic centimetres per turn, about sixty litres a minute at six thousand r p m. The moving parts run in fuel and are lubricated by it, so the pump needs a lubricating flow.
Part 3 · High pressure
The spur gear HP pump Two meshing gears carry fuel round the casing from inlet to outlet Fixed displacement : output depends only on pump speedSimpler and robust, but must be sized for the largest demand Excess fuel is recycled back to the pump inlet by a spill valve Common with FADEC : a pump, a metering valve and a shut-off cock Spur gear HP pump LP fuel in to the FCU spill: fuel not needed returns to the inlet Fixed displacement: output follows pump speed Simpler and robust; sized for the largest demand The FCU (or FADEC) spills the excess back
Chapter 28 · Turbine Engine Fuel Systems
13
e-books by eatpl.in · © 2026 · Do not copy or distribute
The other type of HP pump is the spur gear pump. Two meshing gears trap fuel in the spaces between their teeth and the casing, and carry it round from the inlet to the outlet. It is a fixed displacement pump: each turn delivers the same volume, so the output depends only on how fast the engine is turning it. It is simpler and very robust, but it has to be sized for the largest demand, so at most conditions it delivers more fuel than the engine needs. The excess is recycled back to the inlet side of the pump by a spill valve in the fuel control. Watch the blue return line in the scene. This arrangement is common on modern engines with FADEC, where the fuel system can be reduced to a pump, a metering valve and a shut-off cock.
Part 3 · The fuel control unit
What the fuel control unit does The FCU (or fuel flow regulator) meters the fuel for a given thrust setting The pilot moves the throttle ; the FCU senses the mass of air entering the engine Inputs: RPM , intake pressure P1 and temperature, compressor delivery pressure P3 , EGT It keeps the correct air/fuel ratio automatically Built-in devices: altitude , acceleration , EGT , power and RPM control Metering principle metering valve (area A) to nozzles from HP pump spill ΔP held constant by a spill (bypass) valve Flow ∝ A × √ΔP → with ΔP fixed, flow ∝ A Throttle and the FCU sensors set the area A Doubling ΔP would give only √2 = 1.41 times the flow, so it is the area, not the pressure, that meters
Chapter 28 · Turbine Engine Fuel Systems
14
e-books by eatpl.in · © 2026 · Do not copy or distribute
The fuel control unit, also called the fuel flow regulator, is the brain of a hydro-mechanical fuel system. It controls the fuel flow for a given thrust setting. The pilot moves the throttle, and the FCU senses changes in the mass of air entering the combustion chamber, which depends on engine speed and on the pressure and temperature of the air. It then varies the fuel flow automatically to keep the correct air to fuel ratio. The basic metering idea is shown here. Fuel passes through a metering valve. A spill valve holds the pressure drop across that valve constant, so the flow is simply proportional to the valve opening. Inside the FCU, several devices then adjust the flow for intake pressure, acceleration, exhaust gas temperature, compressor delivery pressure and RPM. We take them one at a time.
Part 3 · The fuel control unit
Altitude control: the barometric pressure capsule Intake pressure P1 changes with altitude and airspeed Fuel flow must change with it so that a fixed RPM is held for a given throttle position A barometric pressure capsule (BPC) expands or contracts with P1 and trims the fuel It sits in the altitude sensing unit of the FCU Climb: P1 falls, capsule expands, fuel reduced Barometric pressure capsule Sea level fuel high P1 high: capsule squeezed High altitude fuel reduced P1 low: capsule expands Why it is needed At FL350 the static pressure is 238 hPa, about 24 % of sea level: each cubic metre of air has far less mass Without a cut in fuel the engine would overspeed and overheat for the same throttle position The capsule holds the selected RPM at all altitudes
Chapter 28 · Turbine Engine Fuel Systems
15
e-books by eatpl.in · © 2026 · Do not copy or distribute
The first FCU device is the altitude control. The pressure at the engine intake, called P one, changes with altitude and with airspeed. At a given RPM, lower intake pressure means much less mass of air passing through the engine. If the fuel flow stayed the same, the mixture would become far too rich, and the engine would overspeed and overheat. So the fuel must change with P one, to keep a fixed RPM for a selected throttle position at all altitudes and airspeeds. This is done by a capsule, the barometric pressure capsule, inside an altitude sensing unit in the FCU. As the aircraft climbs, P one falls, the capsule expands, and through a linkage the fuel flow is reduced. At flight level three five zero, for example, the static pressure is only about a quarter of its sea-level value.
Part 3 · The fuel control unit
Acceleration and deceleration control 50 60 70 80 90 100 Engine speed N (% RPM) fuel flow (relative) SURGE / STALL REGION FLAME-OUT REGION surge line acceleration schedule steady running line deceleration schedule weak extinction line Throttle slammed open: fuel jumps only to the acceleration schedule, rides it as N rises, then settles on the steady running line Throttle closed: fuel cut only to the deceleration schedule Shape illustrative; ratios differ by engine Too much fuel too quickly is the usual cause of compressor stall and surge ; too little when throttling back risks flame-out .
Chapter 28 · Turbine Engine Fuel Systems
16
e-books by eatpl.in · © 2026 · Do not copy or distribute
To make the engine accelerate, we must add fuel. But if fuel is added too quickly, the combustion pressure rises faster than the compressor can speed up, and the compressor stalls or surges. That is the usual cause of surge. So the FCU contains an acceleration control unit. It uses the intake pressure P one and the compressor delivery pressure P three to position a fuel metering plunger, which acts as a second throttle in series with the main one. Look at the chart. When the throttle is slammed open, fuel jumps up only to the acceleration schedule, which lies safely below the surge line, rides that line as the engine speeds up, and settles back on the steady running line at the new speed. This gives the fastest possible acceleration without stall or surge. When you throttle back, a similar schedule keeps fuel above the weak extinction line, so the flame does not go out.
Part 3 · The fuel control unit
Exhaust gas temperature limiting Probably the most important engine parameter: efficiency needs the hottest turbine the materials allow Thermocouples in the gas stream, in or just after the turbineSignal goes to the EGT gauge and to a temperature control signal amplifier The amplified signal powers a solenoid that indirectly reduces fuel flow The pilot can select full power at any time without a turbine meltdown Top temperature control combustor turbine / jet pipe thermocouples EGT gauge temperature control signal amplifier solenoid in FCU trims fuel flow The pilot can select full power without overheating the turbine
Chapter 28 · Turbine Engine Fuel Systems
17
e-books by eatpl.in · © 2026 · Do not copy or distribute
Exhaust gas temperature is probably the most important parameter in a gas turbine. For the best efficiency, the engine must run with the hottest turbine that its materials can stand without melting. To allow that, and still make the engine easy to use, the FCU has a top temperature control. Thermocouple probes sit in the gas stream, either within the turbine or just after it. Their output does two things: it drives the EGT gauge in the cockpit, and it goes to a temperature control signal amplifier. The amplifier powers a solenoid, which indirectly reduces the fuel flow if the temperature reaches the limit. So in the exam, an overheat in the turbine leads to an electrical signal from the thermocouples being amplified and sent to the FCU, which reduces fuel. The result: the pilot can select full power at any time without risking a turbine meltdown.
Part 3 · The fuel control unit
Power limiter and RPM limiter Two more automatic limits stop the engine destroying itself.
P1 and P3 power limiter (capsules, levers) fuel reduced shaft speed (tacho-generator) amplifier (shared with EGT) fuel reduced HP spool speed (hydraulic pressure) governor in the HP pump fuel reduced In every case the FCU answers by cutting fuel; nothing is bled off Power limiter The compressor casing has a maximum pressure . Signalled by P1 and P3 , capsules and levers in the FCU reduce fuel and RPM so the maximum pressure ratio is not exceeded.
RPM limiter: electrical A tacho-generator or electronic speed sensor on the shaft feeds an amplifier (usually the same one as the EGT limiter); near the limit, fuel is trimmed.
RPM limiter: hydro-mechanical Used for the HP spool . A governor in the HP pump senses hydraulic pressure proportional to speed; a diaphragm bleeds servo pressure to cut fuel flow.
Chapter 28 · Turbine Engine Fuel Systems
18
e-books by eatpl.in · © 2026 · Do not copy or distribute
Two more limiters protect the engine. The first is the power limiter. The compressor casing can only take a certain internal pressure; above its design maximum it could burst, with catastrophic results. So the FCU senses intake pressure P one and compressor delivery pressure P three, and through capsules and levers reduces the fuel, and so the RPM, so that the maximum pressure is not exceeded. Notice that the answer is to reduce fuel, not to open a bleed valve. The second is the RPM limiter, because spools turning too fast could fly apart from centrifugal force. There are two methods. An electrical one uses a tacho-generator or electronic speed sensor feeding an amplifier, usually the same amplifier as the temperature limiter. The other, used for the HP spool, is a hydro-mechanical governor inside the HP pump, which bleeds off servo pressure to limit fuel flow.
Part 4 · Delivery
The HP fuel cock The HP cock (HP fuel shut-off valve) is between the FCU and the spray nozzles It is the normal control for starting and stopping the engine Operated by a lever on the flight deck, or by a switch and electric actuator Cuts fuel right at the engine : a clean, quick shutdown The LP valve can stop the engine too, but more slowly Which valve stops the engine? HP cock (HP shut-off valve) between FCU and nozzles normal start and stop: fuel cut at once, quick run-down LP valve (pylon valve) between tank and engine fire handle and maintenance; engine runs on the fuel in its pipes, slower run-down HP cock: a lever on the flight deck, or a switch and an actuator
Chapter 28 · Turbine Engine Fuel Systems
19
e-books by eatpl.in · © 2026 · Do not copy or distribute
The HP fuel cock, or HP fuel shut-off valve, shuts off the fuel between the fuel control unit and the spray nozzles. It is the normal control for starting and stopping the engine: in the start sequence it is opened to let fuel reach the burners once the engine is turning fast enough, and to shut down it is closed. On some aircraft it is a lever on the flight deck, often combined with the thrust lever or a start lever; on others, a switch drives an electric actuator. Because it is right next to the burners, closing it cuts the fuel almost at once, so the shutdown is quick and clean. Compare this with the LP valve upstream, which can also stop the engine, but more slowly, because the engine keeps burning the fuel in the pipes between. So in the exam, the normal stopping device is the HP shut-off valve.
Part 4 · Delivery
Duplex nozzles and the pressurising valve A duplex spray nozzle has a small primary orifice and a larger main orifice At low flow only the primary (pilot) manifold is fed: high pressure, good atomisation A pressurising valve opens at a preset pressure and adds the main manifold The dump valve drains the manifolds to the drains tank on shutdown Why: to stop fuel boiling in hot manifolds from residual engine heat Duplex spray nozzle primary main main spray: wide cone, high flow primary: fine, low flow Low fuel flow (start, idle): primary only small orifice keeps the pressure up: good atomisation Above a set pressure the pressurising valve opens the main manifold adds the main spray for high flow
Chapter 28 · Turbine Engine Fuel Systems
20
e-books by eatpl.in · © 2026 · Do not copy or distribute
A pressurising and dump valve is used with duplex fuel nozzles. A duplex nozzle has two orifices: a small primary one in the centre and a larger main one around it, fed from two separate manifolds. At low fuel flows, such as starting and idle, only the primary, or pilot, manifold is supplied. Its small orifice keeps the pressure high even at low flow, so the fuel is still finely atomised. When the fuel pressure reaches a preset value, the pressurising valve opens and allows fuel into the main manifold as well, and the wide main spray handles the high flows. The dump part of the valve works at shutdown: it lets the fuel in the manifolds drain away to the drains tank. Otherwise residual engine heat would make that trapped fuel boil, and it would leave carbon deposits that could block the nozzles.
Part 4 · Delivery
Why two orifices? The numbers 0 20 40 60 80 100 0 200 400 600 800 1000 Fuel flow (% of maximum) fuel pressure (psi) pressurising valve opens (200 psi) single orifice: only 29 psi duplex nozzle single-orifice nozzle Why duplex? Nozzle flow ∝ √pressure, so a single orifice needs 100 times the pressure for 10 times the flow At 17 % flow (start, idle): single orifice: 29 psi, poor spray duplex primary: 200 psi, fine spray Shutdown: the dump valve drains the manifolds to the drains tank
Chapter 28 · Turbine Engine Fuel Systems
21
e-books by eatpl.in · © 2026 · Do not copy or distribute
Here is why the duplex nozzle exists, with numbers. Flow through an orifice is proportional to the square root of the pressure across it. So a single orifice that needs a thousand psi for full flow would need a hundred times less pressure, only ten psi, at ten per cent of the flow. Look at the grey curve. At about seventeen per cent flow, which is roughly start or idle, a single orifice would have only about twenty-nine psi behind it, far too little to atomise the fuel, so you would get big drops, poor lighting and smoke. The duplex nozzle, the orange curve, sends that flow through the small primary orifice alone, so the pressure is already about two hundred psi. At that point the pressurising valve opens, the main orifice joins in, and the pressure then rises gently to a thousand psi at full flow. Good atomisation across the whole range.
Part 4 · Delivery
The drains tank A small tank that collects unburnt fuel from the manifold and combustion chamber Fills after engine shutdown or after a failed start While the engine runs, a pressure-operated non-return valve isolates it Combustion pressure holds the drain shut when running; it opens on shutdown Prevents fuel pooling in the combustor: no wet start or torching Drains tank combustion chamber / fuel manifold unburnt fuel after shutdown or a failed start NRV drains tank running: closed by combustion pressure stopped: open, fuel drains down Emptied on the ground or burned off later; never sent back to the tanks
Chapter 28 · Turbine Engine Fuel Systems
22
e-books by eatpl.in · © 2026 · Do not copy or distribute
The drains tank is a small tank that collects the unburnt fuel left in the fuel manifold and combustion chamber after the engine is shut down, or after a failed start. When the engine is running, the drain is isolated by a pressure-operated non-return valve: combustion pressure holds it shut, so no fuel or hot gas is lost. Watch the scene: the engine shuts down, the pressure goes, the valve opens, and the residual fuel collects in the tank. This matters because fuel left pooled in a combustion chamber would ignite on the next start, giving a long flame from the jet pipe, called torching, and high temperatures. So, in the exam: when the engine is running, the combustion chamber drain is closed by a pressure-operated non-return valve. The fuel in the drains tank is not returned to the aircraft tanks; it is emptied on the ground, or on some engines fed back to be burned.
Part 4 · Electronic control
Supervisory EEC or full authority (FADEC)? Supervisory EEC FADEC Hardware A computer plus a standard hydro-mechanical FCU Computer does almost everything; fuel system is just pump, metering valve, shut-off cock Who meters fuel The FCU , trimmed by the EEC commands The FADEC directly Monitors EPR, thrust lever angle, Mach number, inlet pressure and temperature All engine parameters, in every mode Job Holds constant thrust despite changes in pressure, temperature or flight conditions All steady-state and transient control, including VIGVs and VSVs If it fails Reverts to manual (hydro-mechanical) control Second channel takes over (dual-channel design) Benefits Better economy, reliability, engine life Same, plus lighter, simpler fuel system and full protection
Chapter 28 · Turbine Engine Fuel Systems
23
e-books by eatpl.in · © 2026 · Do not copy or distribute
Many modern engines use electronic engine control, which gives better fuel economy, better reliability and longer engine life. There are two types. A supervisory engine control system uses a computer that watches the engine, monitoring E P R, thrust lever angle, Mach number and inlet pressure and temperature, and sends commands to a standard hydro-mechanical fuel control unit. The FCU still does the metering and protection, and the computer simply trims it to hold a constant thrust whatever the air pressure, temperature or flight conditions. If the supervisory computer fails, the system reverts to manual, hydro-mechanical control. A full authority digital engine control, or FADEC, takes over virtually all the steady-state and transient control functions, including the variable inlet guide vanes and stator vanes. The traditional hydro-mechanical unit is no longer needed, so the fuel system shrinks to a pump, a control valve and a shut-off cock.
Part 4 · Electronic control
FADEC in practice Receives all the data needed for engine operation Controls the engine in every mode : start, idle, acceleration, deceleration, take-off, climb, cruise Responds to the thrust lever or to the flight management computer thrust demand Prevents exceeding limitations : N1, N2, EGT Also schedules VIGVs, VSVs and bleed valves ; normally two channels FADEC: inputs and outputs FADEC channel A + B thrust lever angle P / T at intake N1, N2 EGT, P3 Mach, altitude fuel metering valve VIGVs and VSVs bleed valves clearance control start and ignition Also: protects N1, N2, EGT limits in every mode from start to take-off, climb, cruise and descent
Chapter 28 · Turbine Engine Fuel Systems
24
e-books by eatpl.in · © 2026 · Do not copy or distribute
So what does a FADEC actually do? It receives all the data needed to run the engine, and controls it through every mode of operation: starting, idle, acceleration and deceleration, take-off, climb and cruise. It sets the thrust in proportion to the thrust lever position, or to the thrust demanded by the flight management computer. All the while it monitors the normal engine parameters and prevents the engine exceeding its limitations, such as N one, N two and exhaust gas temperature. Besides fuel metering, it schedules the variable inlet guide vanes and stator vanes and the compressor bleed valves, which keep the compressor away from surge. Because so much depends on it, a FADEC normally has two independent channels, each able to run the engine alone, with alternate sensors, so a single failure does not stop the engine.
Exam traps
Where is it, and what drives it? Question Answer Trap to avoid Fuel booster pumps are in… The fuel tanks Not in the line or on the engine HP fuel pump driven by… The HP spool (HP compressor) via the gearbox Not the LP compressor or fan Fuel heated by… Compressor air (and the FCOC)Not air-conditioning or bootstrap air FCOC pressures Oil higher than fuelLeak goes oil → fuel Flowmeter position Between HP cock and nozzles Not between the LP and HP pumps Normal engine stop HP cock closedLP valve stops it too, but slowly Turbine overheat Thermocouple signal amplified to the FCU, fuel reduced Not sent directly, not left to the pilot HP compressor over-pressure FCU reduces fuel and RPM Not opening a bleed valve
Chapter 28 · Turbine Engine Fuel Systems
25
e-books by eatpl.in · © 2026 · Do not copy or distribute
This table collects the favourite exam traps. Booster pumps are in the fuel tanks. The HP pump is driven by the HP spool, the HP compressor, through the gearbox, not by the fan or LP compressor. Fuel is heated by compressor air, plus the oil cooler, never by air-conditioning or bootstrap air. In the fuel-cooled oil cooler the oil pressure is higher than the fuel pressure. The flowmeter is between the HP cock and the nozzles. The normal stop is the HP cock; the LP valve also stops the engine, but more slowly. A turbine overheat produces a thermocouple signal that is amplified and sent to the FCU to reduce fuel; it is not sent directly, and it is not left to the pilot to notice. And if the HP compressor outlet pressure tries to exceed its maximum, the FCU reduces fuel and RPM; it does not open a bleed valve.
Summary
Turbine engine fuel systems in eight lines Order Booster pumps → LP valve → LP pump → FCOC → heater → filter → HP pump → FCU → HP cock → flowmeter → nozzles
Supply LP pump keeps HP pump fed; boosters failed = suction, cavitation , descend; tanks vented by ram air
Conditioning FCOC cools oil, heats fuel (oil pressure higher); heater uses compressor air ; filter protects pump and FCU
HP pump HP spool -driven; atomising pressure; swash plate (variable) or gear (fixed + spill); fuel-lubricated
FCU devices BPC for altitude; acceleration unit vs surge; EGT limiter via amplifier; power and RPM limiters
Start and stop HP cock is the normal control; LP valve and fire handle for isolation
Nozzles and drains Duplex nozzle and pressurising valve; dump on shutdown; drains tank shut by pressure NRV when running
Electronics Supervisory EEC trims an FCU and reverts to manual; FADEC does it all, dual channel
Chapter 28 · Turbine Engine Fuel Systems
26
e-books by eatpl.in · © 2026 · Do not copy or distribute
Let us summarise. The order is: booster pumps, LP valve, LP pump, fuel-cooled oil cooler, heater, filter, HP pump, FCU, HP cock, flowmeter and nozzles. The LP pump keeps the HP pump fed; if the boosters fail it must suck, and at high level that risks cavitation. The oil cooler cools the oil and heats the fuel, with oil at the higher pressure; the heater uses compressor air; and the filter protects the pump and FCU. The HP pump is driven by the HP spool and provides atomising pressure. In the FCU, the barometric capsule handles altitude, the acceleration unit prevents surge, the EGT limiter acts through an amplifier, and there are power and RPM limiters. The HP cock is the normal start and stop control. Duplex nozzles use a pressurising valve, and a dump valve and drains tank deal with leftover fuel. Finally, a supervisory EEC trims an FCU, while FADEC does it all.