Chapter 32 covers the remote indicating, or gyro-magnetic, compass: why it is needed, the system and its signal routing, slaving and rapid synchronisation, the detector unit and flux valve, error signal comparison, the heading indicator, free and slaved modes, the annunciator, keeping the gyro level, transmitting heading, and the other facilities found in some systems.
Chapter roadmap
What this chapter covers
01
Why and how Best of compass and gyro; the system, slaving and rapid sync.
02
The flux valve Detector unit, saturation, cosine outputs, three legs.
03
Indicator and controls Error signal, heading indicator, FREE/SLAVE, annunciator.
04
Other facilities Erection, Selsyns, variation, cut-outs, dual systems.
Chapter 32 · Remote Indicating Compass
02
E-books by eatpl.in · © 2026 · Do not copy or distribute
Four parts: why the remote indicating compass is needed and how the system works; the detector unit and flux valve; the heading indicator, its controls and the annunciator; and the other facilities. Then the chapter questions and the Slaved Compass Lab.
01
Why and how
Short-term gyro, long-term magnet.
E-books by eatpl.in · © 2026 · Do not copy or distribute
Part one: why a remote indicating compass, and how it works.
The problem
The compass and the gyro each fail somewhere
Direct reading compass Turning and acceleration errors : cannot be read in a turn.
Magnets in the cockpit, close to deviation sources: lights, motors, iron.
Self-contained: no output to other equipment.
Directional gyro (DGI) No turning or acceleration errors; can feed other equipment.
But no magnetic input : it drifts, and must be reset by hand to the compass at regular intervals.
Gyro-magnetic compass The gyro’s short-term rigidity plus long-term monitoring of the Earth’s field: a servo slaves the gyro to the magnetic input.
Also called remote indicating compass, slaved gyro compass, MHRS.
Chapter 32 · Remote Indicating Compass
04
E-books by eatpl.in · © 2026 · Do not copy or distribute
The direct reading compass has three limitations: turning and acceleration errors, its magnets are in the cockpit close to sources of deviation, and it cannot feed heading to other equipment. The directional gyro removes the turning and acceleration errors and can feed other systems, but it has no magnetic input, so it drifts and must be reset manually. The gyro-magnetic compass combines the short-term rigidity of the gyro with long-term monitoring of the Earth’s field: if the gyro drifts, a servo system slaves it back. It is also known as the remote indicating compass, the slaved gyro compass and the magnetic heading reference system.
Basic system
Flux valve, gyro and a slow servo loop
Detector unit (flux valve, flux detector)Heading indicator : what most people call the compassPrecession (slaving) amplifier and precession (slaving) motor Horizontal gyro , driving the card through a bevel gear and drive shaftPlus a rapid synchronisation facility and an annunciator
Detector unit (flux valve) in the wing tip or fin Heading indicator stators + rotor A precession amplifier Rapid sync − + annunciator Precession motor Horizontal gyro direct drive shaft 3 wires DC precess AC Flux valve senses H; stators re-create it Gyro shaft out of line: AC error signal Amplified, phase detected, rectified to DC Annunciator shows the error Precession motor turns the gyro Shaft and card turn until the error is nulled Synchronised: annunciator just hunts
Chapter 32 · Remote Indicating Compass
05
E-books by eatpl.in · © 2026 · Do not copy or distribute
The system comprises the magnetic detector unit, or flux valve; the heading indicator; the precession or slaving amplifier; the precession or slaving motor; and a horizontal gyro, which in simple systems drives the compass card directly through a bevel gear and a drive shaft. The flux valve senses the Earth’s field and reproduces it in the stators of the heading indicator, where it is compared with the position of the gyro drive shaft. If the gyro drifts, an AC error signal goes to the precession amplifier, where it is amplified, phase detected and rectified to DC, and drives the precession motor, which turns the gyro until the compass is synchronised.
Slaving in 3D
Drift is slaved out; turns need no correction
Steady heading: gyro drifts → error signal → precessed back at about 3°/min In a turn the gyro is rigid and the flux valve heading changes at the same rate: no error signal At switch-on the gyro is random: 90° out would take 30 min at 3°/min Rapid sync : high gain, typically 60°/min , then back to 3°/min
Chapter 32 · Remote Indicating Compass
06
E-books by eatpl.in · © 2026 · Do not copy or distribute
On a steady heading, any difference between the flux valve field and the gyro can only come from gyro drift; the error signal precesses the gyro back at about 3 degrees per minute, slowly, so the card keeps the gyro’s stability. In a turn the gyro, being rigid, does not turn; the case turns round it, and the bevel gear turns the card; the flux valve heading changes at the same rate, so no error signal arises. At switch-on the gyro takes up a random alignment; 90 degrees out would take 30 minutes at 3 degrees per minute, so a rapid synchronisation facility gives a high-gain mode, typically 60 degrees per minute, until the error is zero.
Numbers to know
Rates, limits and names
Item Typical value Why Normal slaving (precession) rate ≈ 3°/min Slow, so the gyro’s stability is kept and short-term field fluctuations are ignored Gyro 90° out at switch-on 30 min at 3°/minUnacceptable: hence rapid synchronisation Rapid synchronisation ≈ 60°/min , a few secondsClutch, spring-loaded switch or automatic high-gain mode Detector freedom (Hooke’s joint) ±25° pitch and roll, none in azimuthPendulous, in an oil-filled case for damping Slaving cut-outs (some systems) 0.18 g or 10° bankFlux valve disconnected; works as a DGI until level again Follow-up rate (second indicator) 500–600°/min Must keep up with aircraft turn rates High-grade gyro drift 0.01–0.1°/h Too good to precess: use a compass coupler instead
Chapter 32 · Remote Indicating Compass
07
E-books by eatpl.in · © 2026 · Do not copy or distribute
The numbers to remember. Normal slaving is slow, about 3 degrees per minute. A gyro 90 degrees out at switch-on would take 30 minutes, so rapid synchronisation runs at about 60 degrees per minute and takes a few seconds. The detector unit can swing 25 degrees in pitch and roll on its Hooke’s joint but not in azimuth. Some systems cut out slaving above 0.18 g or 10 degrees of bank. A follow-up system must turn at 500 to 600 degrees per minute. Very good gyros, drifting 0.01 to 0.1 degrees per hour, are not precessed at all; a compass coupler is used.
02
The flux valve
Saturation, cosines and three legs.
E-books by eatpl.in · © 2026 · Do not copy or distribute
Part two: the detector unit and the flux valve.
Detector unit in 3D
A three-legged flux valve in the wing tip
In the wing tip or fin , away from aircraft magnetism Pendulous on a Hooke’s joint : ±25° in pitch and roll, no rotation in azimuth Sealed case partly filled with oil to damp oscillations Three legs 120° apart; ‘rams’ horns’ only gather flux Each leg’s output ∝ cos(angle to H)
Chapter 32 · Remote Indicating Compass
09
E-books by eatpl.in · © 2026 · Do not copy or distribute
The detector unit is in the part of the aircraft least affected by on-board magnetism, usually a wing tip or the fin. It contains a pendulous detecting element on a Hooke’s joint, free to swing 25 degrees in pitch and roll but not to rotate in azimuth, in a sealed case partly filled with oil to damp oscillations. The flux valve is a three-spoked device; the curved rams’ horns at the ends of the legs only improve flux gathering. Each leg’s output varies as the cosine of the angle between the leg and the horizontal component of the Earth’s field.
How a leg works
Saturation turns the Earth’s field into a signal
AC on the primary drives the two halves in anti-phase : with no field, A + B = 0 The Earth’s field adds a background : one half saturates earlier than the other The resultant now dips twice per cycle Faraday: the pick-off EMF ∝ rate of change of flux, so an AC signal appears Leg along H: maximum · across H: zero
One flux valve leg: AC in, saturation, and what the pick-off sees A B primary coil: AC in secondary (pick-off) coil Earth’s field H along the leg no external field saturation flux in A (red) and B (blue) resultant flux A + B (green) pick-off EMF ∝ rate of change of the resultant A and B cancel: resultant 0, no output Field shifts the baseline: one leg saturates first → output
Chapter 32 · Remote Indicating Compass
10
E-books by eatpl.in · © 2026 · Do not copy or distribute
Alternating current in the primary coil on the centre post produces equal and opposite flux in the two halves of the leg, so with no external field their sum is zero and nothing is induced in the pick-off coil. The Earth’s field adds a background flux, so the positive and negative swings start from a baseline that is not zero. The metal saturates at a certain level, so one half saturates before the other and the resultant flux dips twice per cycle. By Faraday’s law the induced EMF is proportional to the rate of change of flux, so the pick-off coil sees an AC signal. It is greatest with the leg along the field and zero across it.
Why three legs
Cosine outputs, one answer
A leg’s EMF varies as the cosine of its magnetic direction Except at 0° and 180°, one voltage fits two headings A change in supply voltage would also change the reading Three legs 120° apart feed the three legs of a stator : the field is re-created around the drive shaft
H one leg turning through 360° three legs, 120° apart: heading 047° 000° 090° 180° 270° 360° + − leg EMF ∝ cos(angle to H) same voltage: 060° or 300°? A +0.68 B -0.97 C +0.29 three outputs: one heading only One leg: maximum along H, zero across it, but each voltage fits two headings and any change in supply voltage would change the reading Three legs feed the three legs of a stator in the heading indicator which re-creates the Earth’s field round the gyro drive shaft
Chapter 32 · Remote Indicating Compass
11
E-books by eatpl.in · © 2026 · Do not copy or distribute
The EMF induced in a leg varies as the cosine of its magnetic direction: maximum along the field, zero across it. That cannot be turned directly into heading, because except at 0 and 180 degrees each voltage fits two headings, and any change in the supply voltage would change the reading. So three legs at 120 degrees are used, each feeding one of the three legs of a stator in the heading indicator, which re-creates the Earth’s field, relative to the flux valve, around the drive shaft from the gyro.
03
Indicator and controls
Rotor, stator, card and switches.
E-books by eatpl.in · © 2026 · Do not copy or distribute
Part three: the error signal, the heading indicator and its controls.
Error signal comparison
Rotor meets stator: amplify, detect phase, rectify
Rotor–stator comparison A coil, the rotor , on the gyro drive shaft sits in the stator field.
At 90° to the field: no voltage, the null . Anywhere else: an error voltage.
Amplified · phase detected Amplified : too weak to drive the motor otherwise.
Phase detected : the motor must know which way to turn: 2° clockwise is corrected 2° anticlockwise, not 358°.
Rectified The precession motor is a solenoid acting on a permanent magnet: it needs DC .
Positive or negative by phase: the shaft turns the shortest way to the null.
Chapter 32 · Remote Indicating Compass
13
E-books by eatpl.in · © 2026 · Do not copy or distribute
The error is detected by rotor and stator comparison. A wound coil, the rotor, is mounted on the gyro drive shaft in the field produced by the stators. If it is at 90 degrees to the field no voltage is induced, the null position; anywhere else an error voltage appears and goes to the precession amplifier. It is amplified, because it is too weak to drive the motor; phase detected, so that the motor knows which way to turn, correcting 2 degrees clockwise by 2 degrees anticlockwise rather than 358 degrees; and rectified to DC, because the precession motor is a solenoid acting on a permanent magnet, positive or negative for the shortest way to the null.
Heading indicator and controls
Lubber line, bug, flag and FREE/SLAVE
Card driven by the gyro shaft, read against the lubber line Heading selector sets the bug ; a warning flag shows if the magnetic input fails FREE : flux valve off, the gyro acts as a DGI; reset with the CCW/CW switchAnnunciator : shows monitoring is happening and which way to synchronise
N 3 6 E 12 15 S 21 24 W 30 33 lubber line aircraft symbol heading selector heading bug COMPASS CONTROL − + annunciator SLAVE FREE CCW CW spring-loaded to centre SLAVE: the annunciator hunts gently turn the selector: the bug moves to 090° FREE: flux valve disconnected, a DGI hold CW to set 052° from the standby compass heading 047°M reset to 052°
Chapter 32 · Remote Indicating Compass
14
E-books by eatpl.in · © 2026 · Do not copy or distribute
The heading indicator card is driven by the shaft from the gyro and read against the lubber line at 12 o’clock. The pilot sets a desired heading with the heading selector, shown by the bug; a heading warning flag appears if the magnetic input from the flux valve fails. If the flux valve fails, or near the magnetic poles, the compass can be used in FREE mode: the flux valve signal is disconnected and the gyro acts as a DGI, reset to the standby compass with the spring-loaded CCW/CW switch. The annunciator shows that magnetic monitoring is taking place, hunting gently when synchronised, and on manual systems which way to synchronise.
Keeping it level · sending heading
Topple, erection and the Selsyn
Drift and topple Drift is cured by slaving to the flux valve: tied in azimuth.
Topple : the gyro must also be tied to the yaw axis (commutators, inner and outer gimbals kept at 90°) or to gravity (mercury switches).
Torque motor A levelling switch drives a torque motor acting about the yaw axis.
The precession returns the gyro to horizontal, slowly , so turns, accelerations, climbs and descents do not upset it.
Selsyn transmission Heading is picked off the drive shaft by a Selsyn rotor fed with AC.
Three wires reproduce the field in a repeater; its rotor is driven to the null, so it follows the heading.
Chapter 32 · Remote Indicating Compass
15
E-books by eatpl.in · © 2026 · Do not copy or distribute
Gyro wander takes two forms, drift and topple. Drift is overcome by slaving the gyro to the flux valve, a tied gyro in azimuth. Topple is prevented by tying the gyro to the aircraft yaw axis, keeping the inner and outer gimbals at 90 degrees with commutators, insulating strips and brushes, or to gravity with mercury switches. Either way a torque motor applies a force about the yaw axis and the gyro precesses slowly back to the horizontal. Heading is transmitted to other instruments by a Selsyn: a rotor on the drive shaft, fed with AC, induces a field in its stators, reproduced over three wires in a repeater, whose rotor is driven to the null and so follows the heading.
04
Other facilities
Found in some systems.
E-books by eatpl.in · © 2026 · Do not copy or distribute
Part four: other facilities, not found in all gyro-magnetic compasses.
Transmitting heading
The Selsyn repeats the shaft
Heading is picked off the drive shaft between gyro and card Transmitter rotor fed with constant AC: induces a field in its stators Three wires reproduce the same field in the repeater statorsRepeater rotor off the null → voltage → amplifier and motor turn it until no voltage remains
Selsyn: heading from the gyro shaft to a repeater Transmitter (on the gyro shaft) Repeater 3-wire link rotor fed with AC rotor driven to the null amp + motor gyro heading 030° gyro heading 120° gyro heading 030° repeater 030° repeater 120° repeater 030° repeater rotor not at the null → voltage → motor turns it until none is left
Chapter 32 · Remote Indicating Compass
17
E-books by eatpl.in · © 2026 · Do not copy or distribute
One advantage of the gyro-magnetic compass is that heading can be transmitted electrically to other instruments. It is picked off the drive shaft between the gyro and the card by a Selsyn unit. The transmitter rotor, attached to the drive shaft and fed with a constant AC voltage, induces a field in its stators; three wires connect them to the repeater stators, so an identical field is reproduced there. If the repeater rotor is not perpendicular to that field, a voltage is induced in it, amplified and fed to a motor which turns the repeater shaft until no voltage remains. The repeater follows every heading change of the main shaft.
Other facilities
Found in some gyro-magnetic compasses
Facility What it does Variation correction A knob offsets the stators by the variation: the gyro takes up True heading. Crew must keep it updated and convert back to magnetic for ATC; later a TRUE/MAG switch Acceleration and bank cut-outs The pendulous detector swings in turns and accelerations; slow slaving keeps the effect small. Cut-outs at 0.18 g or 10° bank disconnect the flux valve: a DGI meanwhile Two indicators, one gyro The second indicator is driven by a follow-up amplifier and motor at a fast rate, 500–600°/min; the gyro is still precessed slowly, ≈3°/min Remote systems (compass coupler) Gyros drifting only 0.01–0.1°/h are not precessed; a stepper motor slowly adds the flux valve error to the gyro output Dual systems Two complete compasses: NORMAL, or BOTH ON 1 / BOTH ON 2 after a failure
Chapter 32 · Remote Indicating Compass
18
E-books by eatpl.in · © 2026 · Do not copy or distribute
Some compasses have extra facilities. Variation correction offsets the stators so the gyro takes up True heading; the crew must keep the variation updated and convert back to magnetic for ATC, and later sets had a TRUE/MAG switch. The detector is pendulous, so it swings in turns and accelerations; slow slaving keeps this small, and some systems disconnect the flux valve above 0.18 g or 10 degrees of bank. Two indicators can share one gyro with a fast follow-up system. Very good gyros are not precessed: a compass coupler adds the flux valve error slowly through a stepper motor. Dual systems can feed both indicators from either compass.
Summary
The remote indicating compass in six lines
Topic Remember Why Gyro: short-term rigidity, no turning or acceleration errors · flux valve: long-term magnetic datum, away from deviation, output to other systems System Flux valve → stators → rotor error → amplifier (amplify, phase detect, rectify to DC) → precession motor → gyro → shaft → card Rates Slaving ≈3°/min · rapid sync ≈60°/min · follow-up 500–600°/min · cut-outs 0.18 g, 10° bank Flux valve Wing tip or fin · Hooke’s joint ±25°, fixed in azimuth, oil damped · saturation, EMF ∝ cos · three legs to a stator Controls Lubber line, bug, warning flag · FREE (DGI, CCW/CW) or SLAVE · annunciator shows monitoring and sense Extras Erection to yaw axis or gravity · Selsyn repeaters · variation correction · two indicators, coupler, dual systems
Chapter 32 · Remote Indicating Compass
19
E-books by eatpl.in · © 2026 · Do not copy or distribute
In summary: the gyro-magnetic compass combines the short-term stability of a gyro with the long-term directional reference of the Earth’s field. The error loop runs from flux valve to stators, rotor, amplifier and precession motor to the gyro and back through the drive shaft. Slaving is slow, about 3 degrees per minute, with rapid synchronisation at about 60. The flux valve sits in a wing tip or fin, pendulous on a Hooke’s joint, and uses saturation; its three legs feed a stator. The indicator has a lubber line, bug and warning flag; FREE and SLAVE modes; and an annunciator.
Questions 1–4
Questions: set 1
1. A gyro-magnetic compass or magnetic heading reference unit always consists of: 1 a directional gyro, 2 a vertical axis gyro, 3 an earth’s magnetic field detector, 4 an azimuth control, 5 a synchronising control. (a) 2 and 5 (b) 1, 3 and 5 (c) 2, 3 and 5 (d) 1 and 4
2. A slaved directional gyro derives its directional signal from: (a) a direct reading magnetic compass (b) the flight director (c) the flux valve (d) the air data computer
3. The gyro-magnetic compass torque motor: (a) causes the directional gyro unit to precess (b) causes the heading indicator to precess (c) feeds the error detector system (d) is fed by the flux valve
4. The heading information originating from the gyro-magnetic compass flux valve is sent to: (a) error detector (b) erector system (c) heading indicator (d) amplifier
Chapter 32 · Remote Indicating Compass
20
E-books by eatpl.in · © 2026 · Do not copy or distribute
Questions 5–7
Questions: set 2
5. The input signal of the amplifier of the gyro-magnetic compass resetting device originates from the: (a) directional gyro erection device (b) error detector (c) flux valve (d) directional gyro unit
6. Heading information from the gyro-magnetic compass flux gate is transmitted to the: (a) amplifier (b) error detector (c) erecting system (d) heading indicator
7. A flux valve senses changes in orientation of the horizontal component of the earth’s field: 1 made of a pair of soft iron bars, 2 the primary coils are fed AC, 3 the information can be used by a flux gate compass or a directional gyro, 4 the casing is dependent on the aircraft’s three inertial axes, 5 accuracy of the field indication is less than 0.5%. (a) 2, 3 and 5 (b) 1, 3, 4 and 5 (c) 3 and 5 (d) 1, 4 and 5
Chapter 32 · Remote Indicating Compass
21
E-books by eatpl.in · © 2026 · Do not copy or distribute
Answers
Answers with the reasoning
Q Answer Why 1 (b) 1, 3 and 5 A directional (horizontal axis) gyro, a magnetic field detector (flux valve) and a synchronising control 2 (c) The flux valve in the wing tip or fin 3 (a) The torque (precession) motor precesses the directional gyro 4 (a) To the error detector: the stators, compared with the rotor on the gyro shaft 5 (b) The precession amplifier is fed by the error detector (rotor–stator comparison) 6 (b) As Q4: the error detector 7 (a) 2, 3 and 5 AC primary; feeds a flux gate compass or slaved gyro; accurate. Not two plain soft iron bars (three saturable legs); the sensing element is pendulous, not tied to the aircraft’s three axes
Chapter 32 · Remote Indicating Compass
22
E-books by eatpl.in · © 2026 · Do not copy or distribute
Answers with the reasoning.
Try it yourself
Slaved Compass Lab
Fly a gyro-magnetic compass: 3D heading indicator, annunciator and flux valve Gyro drift, slaving at 3°/min and rapid sync at 60°/min Turns and accelerations, with and without bank and g cut-outs FREE and SLAVE modes, CCW/CW reset, flux valve failure The chapter questions plus worked timing problems Open the Slaved Compass Lab →
N 3 6 E 12 15 S 21 24 W 30 33
Chapter 32 · Remote Indicating Compass
23
E-books by eatpl.in · © 2026 · Do not copy or distribute
The Slaved Compass Lab simulates a gyro-magnetic compass with a 3D heading indicator, annunciator and flux valve display: gyro drift and slaving, rapid synchronisation, turns and accelerations with cut-outs, FREE and SLAVE modes and flux valve failure, with the chapter questions and timing problems.
eatpl.in · General Navigation · Chapter 32
Slaved Compass Lab
Fly a gyro-magnetic compass. The gyro drifts, the flux valve slaves it back slowly, turns need no correction, and rapid sync fixes a random start. A teaching model with typical rates.
Simulator
Practice
The seven questions, then timing problems. Set up puts the simulator in the matching state; Answer shows the answer and why.
E-book and lab by eatpl.in · © 2026 eatpl.in. For the personal study of eatpl.in students. Do not copy or distribute.