Aircraft Instruments · Chapter 39
Engine instruments in depth: performance and condition indicators, EPR and jet pipe pressure, torque, tachometers and speed probes, synchroscopes, thermocouples and gas temperatures, air temperature, pressure elements and MAP, vibration, fuel quantity and flow, Desynn and synchro transmission.
Exclusive study material prepared by eatpl.in
Arrow keys, the buttons or swipe to move between pages. The Lab is below the e-book.
Instruments · Chapter 39
Thrust and power, speed, temperature, pressure, vibration and fuel: how each is sensed and shown to the crew.
Introduction
Types of display
Thrust measurement
EPR on take-off
Worked examples
| Situation | Working | Result |
|---|---|---|
| Pt2 = 14.7 psi, Pt7 = 22.0 psi | 22.0 ÷ 14.7 | EPR ≈ 1.50 |
| Rolling: Pt2 rises to 15.2 psi, Pt7 still 22.0 | 22.0 ÷ 15.2 | EPR ≈ 1.45: apparent drop |
| Engine at FL350: Pt2 = 5.0 psi, Pt7 = 7.5 | 7.5 ÷ 5.0 | EPR 1.50: a ratio, so altitude cancels |
| Pt2 probe iced (senses too low) | denominator too small | EPR over-reads: real thrust lower |
| Pt7 probe leaking (senses too low) | numerator too small | EPR under-reads: real thrust higher |
Always cross-check EPR with N1, N2 and EGT: one wrong probe gives a convincing but false thrust reading.
Turboprop power
Torquemeter (oil)
Torquemeter (electronic)
Engine speed
Engine speed
Speed indication
Engine speed
Multi-engine
Temperature
| Type | Principle | Typical use |
|---|---|---|
| Expansion | Solids, liquids, gases expand with heat (bimetallic strip, liquid thermometer) | Low temperatures, direct reading (e.g. OAT) |
| Vapour pressure | Pressure of a vapour rises with temperature | Low temperatures, direct reading |
| Electrical resistance | Resistance of a wire changes with temperature (temperature bulb) | Oil, fuel, air temperatures |
| Thermocouple | Two dissimilar metals: EMF ∝ temperature difference of the junctions (Seebeck effect) | High temperatures: EGT, CHT |
| Radiation (pyrometer) | Radiation emitted depends on temperature (emissivity) | Turbine blade temperature |
Temperatures monitored range from about −56 °C to over 1200 °C. Ratiometer circuits give extra accuracy for critical components.
Gas temperature
Where the probes go
Air temperature for engines
Pressure gauges
Piston engines
Engine health
Fuel quantity
Fuel quantity
Capacitance details
| Item | What happens |
|---|---|
| Colder fuel | Volume ↓, density ↑, εr ↑: compensator on the reference unit corrects, so the gauge shows mass |
| Reference unit | Always submerged in unusable fuel; corrects for changes in fuel permittivity |
| Water in the tank | Conducts: shorts the tank unit, indicator driven beyond full scale |
| System failure | Fail-safe: pointer driven slowly to zero |
| Test switch | Simulates emptying; pointer must return when released |
| Totaliser | Shows the sum of all tanks |
| Red arc | If unusable fuel exceeds 1 gal or 5 % of tank capacity, whichever is greater: red arc from zero to the lowest usable reading |
Fuel flow
Data transmission
Watch out
Summary