Aircraft Instruments · Chapter 6
How the VSI turns a changing static pressure into feet per minute: capsule and metering unit, errors and blockages, the instantaneous VSI, scales, serviceability checks and the 1 in 60 rule for approaches.
Exclusive study material prepared by eatpl.in
Arrow keys, the buttons or swipe to move between pages. The Lab is below the e-book.
Instruments · Chapter 6
A capsule, a leak and a stopwatch built into one case: the VSI turns the rate of change of static pressure into feet per minute.
Introduction
Principle
Reading the pressures
Construction
Metering unit
Metering unit in numbers
| Level (ISA) | Height per 1 hPa | 1000 ft/min means |
|---|---|---|
| MSL | ≈ 27 ft | ≈ 36.6 hPa/min |
| FL100 | ≈ 37 ft | ≈ 27.0 hPa/min |
| FL200 | ≈ 51 ft | ≈ 19.5 hPa/min |
| FL300 | ≈ 73 ft | ≈ 13.7 hPa/min |
| FL400 | ≈ 111 ft | ≈ 9.0 hPa/min |
The capsule sees hPa/min; the dial must show ft/min. The capillary + orifice choke makes the scale right at every level.
Lag
Errors (1)
Errors (2)
Errors
| Error | Cause | What you see |
|---|---|---|
| Instrument | Manufacturing tolerances, friction | Small offsets; zero-adjust screw |
| Lag | Time for the pressure difference to build or decay | Late response starting and stopping a climb |
| Position (pressure) | Static source error changes with speed and AoA | False climb or descent when speed changes, e.g. on the take-off run |
| Manoeuvre-induced | Short pressure surges at the vent in attitude changes | Brief false readings, e.g. go-around, gear and flap changes |
| Reversal | Sudden pitch change alters the static error at the vent | Needle first moves the wrong way, then corrects |
The VSI is not affected by a constant position error: only by a change in it.
Blockage
Blockages and leaks
| Fault | VSI indication |
|---|---|
| Static vent blocked | Returns to zero and stays there, whatever the aircraft does |
| Metering unit (choke) blocked | Case sealed: reading now shows height change since the blockage, not rate; it stays off zero in level flight |
| Alternate static (cabin) selected | Brief climb indication (lower pressure), then reads normally |
| VSI glass broken to get static | Case open to cabin: the VSI is unusable |
| Pitot blocked | No effect: the VSI does not use pitot pressure |
A VSI stuck at zero with a frozen altimeter means the static source is blocked.
Instantaneous VSI
IVSI errors
Presentation
Serviceability
The 1 in 60 rule
Using the VSI
Practice
| Groundspeed / case | Rule of thumb | Exact (tan 3°) |
|---|---|---|
| 90 kt | 450 ft/min | ≈ 480 ft/min |
| 120 kt | 600 ft/min | ≈ 640 ft/min |
| 140 kt | 700 ft/min | ≈ 740 ft/min |
| 160 kt | 800 ft/min | ≈ 850 ft/min |
| Height at 4 nm | 4 × 300 = 1200 ft | ≈ 1270 ft |
| IAS 130 kt, 20 kt headwind | GS 110 → 550 ft/min | ≈ 580 ft/min |
Always use GROUNDSPEED: a headwind needs a lower rate, a tailwind a higher one.
Gliders
Exam traps
Summary