#1. The voltage of a fully charged lead-acid battery cell is :
#2. Batteries are rated in :
#3. When carrying out battery condition check using the aircraft’s voltmeter :
#4. Connecting two 12 volt 40 ampere-hour capacity batteries in series will result in a total voltage and capacity respectively of :
#5. The capacity of a battery is expressed in terms of :
#6. A test to assess the state of charge of a lead-acid battery would involve :
#7. When a battery is almost fully discharged there is a tendency for the :
#8. Immediately after starting engine(s) with no other electrical services switched on, an ammeter showing a high charge rate to the battery :
#9. A relay is :
#10. A relay is :
#11. When a conductor cuts the flux of a magnetic field :
#12. A circuit breaker :
#13. Circuit breakers protecting circuits may be :
#14. A “”trip-free”” type circuit breaker is a circuit protection device which :
#15. In order to produce an alternating voltage of 400 Hz, the number of poles required in an AC generator running at 6000 rpm is:
#16. In a generator, the Constant Speed Drive (CSD):1- may be disconnected from the engine shaft.2- may be disconnected from the generator.3- is a hydro-mechanical system.4- is an electronic system.5- may not be disconnected in flight.6- may be disconnected in flight.The combination regrouping all the correct statements is :
#17. In an alternator rotor coil you can find :
#18. Assume a constant speed DC generator providing a constant output voltage. If the electrical load increases, the voltage regulator will :
#19. The essential difference between aircraft AC alternators and DC generators (dynamos) is that the:
#20. A feeder fault on a direct current circuit results from a flux unbalance between the:
#21. The detection of a feeder fault on a direct current circuit results in:1. automatic disconnection of the generator from the aircraft AC busbar2. opening of generator field current relay3. opening of the main relay of the generator breaker4. opening of balancing circuit connecting two generators5. lighting of an indicator lampThe combination of correct statements is:
#22. A DC generator fitted to a aircraft is cooled by :
#23. The voltage regulator of a DC generator is connected in :
#24. The output of a generator is controlled by :
#25. In order that DC generators will achieve equal load sharing when operating in parallel, it is necessary to ensure that :
#26. On-board electrical systems are protected against faults of the following type:1. AC generator over-voltage2. AC generator under-voltage3. over-current4. overspeed5. under-frequency6. undue vibration of AC generatorsThe combination of correct statements is :
#27. The frequency of the current provided by an alternator depends on…
#28. The function of the Generator Breaker is to close when the voltage of the :
#29. The so-called “”hot buses”” or “”direct buses”” are:
#30. The type of windings commonly used in DC starter motors are :
#31. A bus-bar is :
#32. When two DC generators are operating in parallel, control of load sharing is achieved by :
#33. In a two generator system, a differential relay will ensure that :
#34. The purpose of a battery protection unit is generally to isolate the battery:1 – from the bus when the battery charge is deemed satisfactory2 – when there is a battery overheat condition3 – in case of an internal short circuit4 – in case of a fault on the ground power unitThe combination which regroups all of the correct statements is :
#35. A static inverter is a:
#36. The reason for using inverters in an electrical system is ..
#37. In an aircraft equipped with a DC main power system, AC for instrument operation may be obtained from :
#38. A unit that converts electrical DC into AC is:
#39. Static dischargers :1. are used to set all the parts of the airframe to the same electrical potential2. are placed on wing and tail tips to facilitate electrical discharge3. are used to reset the electrostatic potential of the aircraft to a value approximating 0 volts4. are located on wing and tail tips to reduce intererence with the on-board radiocommunication systems to a minimum5. limit the risks of transfer of electrical charges between the aircraft and the electrified cloudsThe combination regrouping all the correct statements is :
#40. The advantages of grounding the negative pole of the aircraft structure are:1. Weight saving2. Easy fault detection3. Increase of short-circuit risk4. Reduction of short-circuit risk5. Circuits are not single-wired linesThe combination regrouping all the correct statements is :
#41. Electrical bonding of an aircraft is used to:1. protect the aircraft against lightning effects.2. reset the electrostatic potential of the aircraft to a value approximating 0 volt3. reduce radio interference on radiocommunication systems4. set the aircraft to a single potentialThe combination regrouping all the correct statements is:
#42. The purpose of static wick dischargers is to :
#43. It may be determined that an aircraft is not properly bonded if :
#44. The primary purpose of bonding the metallic parts of an aircraft is to :
#45. The most widely used electrical frequency in aircraft is :
#46. The advantages of alternating current on board an aircraft are:1. simple connection2. high starting torque3. flexibility in use4. lighter weight of equipment5. easy to convert into direct current6. easy maintenance of machinesThe combination of correct statements is:
#47. If the frequency of the supply in a series capacitive circuit is increased, the current flowing in the circuit will :
#48. When the AC generators are connected in parallel, the reactive loads are balanced by means of the:
#49. The main purpose of a Constant Speed Drive unit is to:
#50. The Auxiliary Power Unit (APU) has its own AC generator which:
#51. In flight, if the constant speed drive (CSD) temperature indicator is in the red arc the:
#52. As regards the Generator Contol Unit (GCU) of an AC generator, it can be said that:1. The GCU controls the AC generator voltage2. Modern GCUs are provided with a permanent indication to record the failure3. All the commands originating from the control panel are applied via the GCU, except dog clutch release4. The Auxiliary Power Unit (APU) provides the excitation of the AC generator as soon as the APU starts upThe combination regrouping all the correct statements is :
#53. On starting, in a brushless AC generator with no commutator rings, the generator is activated by:
#54. A CSD of an AC generator may be disconnected in flight. The primary reason(s) for disconnection are :
#55. A CSD unit which has been disconnected in flight :
#56. The frequency of an AC generator is dependent upon the :
#57. The function of a constant speed drive (CSD) in an AC generating system is to :
#58. If two constant frequency AC generators are operating independently, then the phase relationship of each generator:
#59. The purpose of a voltage regulator is to control the output voltage of the :
#60. A 3 phase AC generator has 3 separate stator windings spaced at :
#61. On the flight deck, an oil operated CSD unit is normally provided with means of monitoring the:
#62. An AC generator driven by a CSD unit :
#63. Assuming a CSD fault is indicated, the CSD should be disconnected :
#64. The measured output power components of a constant frequency AC system are :
#65. “”Frequency wild”” in relation to a AC generation system means the generator :
#66. The function of a CSD in an AC generating system is to:
#67. The frequency of an AC generator is dependent on the :
#68. Constant Speed Drive aims at ensuring
#69. A thermal circuit breaker:
#70. In an aircraft electrical system where AC generators are not paralleled mounted, the changover relay allows :
#71. Pulling the fire shutoff handle causes a number of devices to disconnect. In respect of the AC generator it can be said that the:
#72. As regards three-phase AC generators, the following conditions must be met for paralleling AC generators:1. Equal voltage2. Equal current3. Equal frequencies4. Same phase rotation5. Voltages of same phaseThe combination regrouping all the correct statements is :
#73. A magnetic circuit-breaker is:
#74. When a persistent top excitation limit fault on an AC generator connected to the mains with another AC generator, the overexcitation protection device opens:
#75. When a persistent overexcitation fault is detected on only one AC generator, the protection device opens the :
#76. When an underspeed fault is detected on an AC generator connected to the aircraft AC busbar, the protection device opens the:
#77. The services connected to a supply bus-bar are normally in:
#78. To ensure correct load sharing between AC generators operating in parallel :
#79. When operating two AC generators unparalleled, the phase relationship of each generator:
#80. When AC generators are operated in paralllel, they must be of the same:
#81. Real load sharing in a parallel AC system is achieved by :
#82. Real load sharing in a parallel AC system is achieved by :
#83. Load shedding means ..
#84. The speed of an asynchronous four-pole motor fed at a frequency of 400 Hertz is:
#85. In an aeroplane utilising a constant frequency AC power supply, DC power is obtained from a :
#86. On an aeroplane utilising AC as primary power supplies, the batteries are charged in flight from :