About this topic
OXFORD ELECTRIC Circuit protection and capacitors: 20 multiple-choice questions for the DGCA CPL and ATPL examinations. Every question shows the correct answer and an explanation. You can practise free for a few minutes; a subscription opens every question bank, previous paper and airline preparation set.
Sample questions from OXFORD ELECTRIC Circuit protection and capacitors
- In a circuit fitted with a non trip free circuit breaker if a fault occurs and persists:
- A) if the reset button is depressed and held in, the circuit will be made.
- B) the trip button may be pressed to reset, but not permanently.
- C) a non trip free circuit breaker can never be by-passed.
- D) the reset button may be pressed to make the circuit permanent.
Show answer
A) if the reset button is depressed and held in, the circuit will be made.
- A trip-free circuit breaker that has tripped due to overload:
- A) can be reset and held in during rectification.
- B) can never be reset.
- C) can be reset after overhaul.
- D) maybe reset manually after fault has been cleared.
Show answer
D) maybe reset manually after fault has been cleared.
- Circuit breakers and fuses
- A) are used in DC circuits only
- B) are used in AC or DC circuits
- C) are used in AC circuits only
- D) are used in low current circuits only
Show answer
B) are used in AC or DC circuits
- A trip-free circuit breaker is one which:
- A) cannot be reset by holding the lever in while the fault persists.
- B) can be reset by holding the lever in while the fault persists.
- C) must be held in during checks to find faults.
- D) can be by passed.
Show answer
A) cannot be reset by holding the lever in while the fault persists.
- If the reset button is pressed in the trip-free circuit breaker, the contacts with the fault cleared will:
- A) be made and kept made.
- B) only be made if there is a fuse in the circuit.
- C) reset itself only after a delay of 20 seconds.
- D) not be made and the reset will remain inoperative.
Show answer
A) be made and kept made.