About this topic
OXFORD SYSTEMS Oxygen equipment: 26 multiple-choice questions for the DGCA CPL and ATPL examinations. Every question shows the correct answer and an explanation. You can practise free for a few minutes; a subscription opens every question bank, previous paper and airline preparation set.
Sample questions from OXFORD SYSTEMS Oxygen equipment
- Without added oxygen the time of useful consciousness at 30000 ft is approximately:
- A) twenty seconds
- B) eighty seconds
- C) one to two minutes
- D) six minutes
Show answer
C) one to two minutes
Without added oxygen, the time of useful consciousness at 30,000 ft is approximately one to two minutes. At this altitude, hypoxia sets in quickly due to low oxygen partial pressure, severely impairing cognitive and motor functions. - Without added oxygen the time of useful consciousness at 40000 ft is approximately:
- A) twenty seconds
- B) three minutes
- C) eighty seconds
- D) six minutes
Show answer
A) twenty seconds
At 40,000 ft, without added oxygen, the time of useful consciousness is approximately twenty seconds. At this altitude, hypoxia rapidly impairs brain function, giving very little time for corrective action. - The maximum altitude without oxygen at which flying efficiency is not seriously impaired is:
- A) 10,000 feet
- B) 17,500 feet
- C) 25,000 feet
- D) 30,000 feet
Show answer
A) 10,000 feet
Hypoxia, which is insufficient oxygen, can occur above an altitude of 10,000 ft. At altitudes up to 10,000 ft (3.3 km), the air pressure and oxygen levels are generally sufficient for humans to operate without significant problems. However, crew members must be on oxygen if the cabin altitude reaches 10,000 ft, and passengers must be on emergency oxygen at 15,000 ft cabin altitude. - In a pressure demand oxygen system:
- A) Each member of the crew has a regulator
- B) Each member of the crew has a continuous oxygen supply
- C) Oxygen is supplied with a continuous pressure flow
- D) Oxygen demand will cause the pressure to rise
Show answer
A) Each member of the crew has a regulator
In a pressure demand oxygen system, oxygen is delivered as demanded by the user’s respiration cycle and the oxygen regulator. This type of system is specifically provided for flight crew use, and as such, each crew member is equipped with their own regulator, often integrated into their mask, such as with EROS Crew Oxygen Masks. - In a continuous flow oxygen system, oxygen is supplied:
- A) only when the mask is plugged into the socket connection
- B) only on passenger inhalation through the mask
- C) only when the cabin altitude is above 18000 f
- D) only when the supply has been regulated by the pilot
Show answer
A) only when the mask is plugged into the socket connection
In a continuous flow oxygen system, oxygen is supplied only when the mask is plugged into the socket connection or, for “drop-out” passenger masks, when the passenger pulls the mask towards their face. This action initiates the oxygen flow at a continuous rate, as this system does not deliver oxygen based on a user’s inhalation cycle.