About this topic
OXFORD SYSTEMS Pressurisation systems: 50 multiple-choice questions for the DGCA CPL and ATPL examinations. Every question shows the correct answer and an explanation. You can practise free for a few minutes; a subscription opens every question bank, previous paper and airline preparation set.
Sample questions from OXFORD SYSTEMS Pressurisation systems
- Main and nose wheel bays are:
- A) pressurised.
- B) unpressurised.
- C) conditioned.
- D) different, with the mains being unpressurised and the nose pressurised.
Show answer
B) unpressurised.
Both main and nose wheel bays are typically unpressurised, as they are not part of the aircraft’s pressurised cabin or systems. These bays are isolated from the pressurised fuselage to handle landing gear operations and prevent pressure-related complications during gear extension or retraction. - Normal maximum negative differential pressure is:
- A) when atmospheric pressure exceeds cabin pressure by the amount permitted by the system controls.
- B) where the cabin pressure falls below aircraft altitude pressure at which time the inward relief valve opens.
- C) when the cabin pressure exceeds the atmospheric pressure by 0.5 PSI.
- D) the pressure at which the duct relief valve is set to operate.
Show answer
A) when atmospheric pressure exceeds cabin pressure by the amount permitted by the system controls.
Negative differential pressure occurs when outside atmospheric pressure is greater than cabin pressure. To prevent structural damage, system controls limit this difference. The negative relief valve opens when this maximum negative differential pressure is reached, protecting the aircraft structure from inward pressure loads. - When would the negative differential limit be reached/exceeded:
- A) rapid descent when AC descends below cabin altitude.
- B) during ground pressure testing.
- C) rapid ascent when aircraft climbs.
- D) when changing to manual operation.
Show answer
A) rapid descent when AC descends below cabin altitude.
The negative differential limit may be reached or exceeded when the aircraft descends rapidly, and the cabin altitude remains higher than the outside atmospheric pressure. This creates a condition where external pressure exceeds internal cabin pressure, potentially stressing the fuselage inward, which the negative relief valve prevents. - A/C in level flight if cabin altitude increases does pressure diff:
- A) increase.
- B) decrease.
- C) remain the same.
- D) nil.
Show answer
B) decrease.
In level flight, if the cabin altitude increases, it means the cabin pressure is decreasing (approaching outside pressure). Since pressure differential = cabin pressure – atmospheric pressure, a drop in cabin pressure causes the pressure differential to decrease. - In level pressurised flight does the outflow valve:
- A) close.
- B) adjust to provide constant flow, and is normally partially open.
- C) open to increase air conditioning.
- D) adjust to provide constant flow, and is normally almost closed.
Show answer
B) adjust to provide constant flow, and is normally partially open.
In level pressurised flight, the outflow valve automatically adjusts to maintain the desired cabin pressure by regulating the outflow of air. It stays partially open to allow a controlled and constant flow, balancing the inflow from the air conditioning packs and maintaining a stable pressure differential.