PRESSURE HEADS

10 questions · tap an answer to check it

Learn this topic firstPressure HeadsInstruments course →

About this topic

PRESSURE HEADS: 10 multiple-choice questions for the DGCA CPL and ATPL examinations. Every question shows the correct answer and an explanation. You can practise free for a few minutes; a subscription opens every question bank, previous paper and airline preparation set.

Sample questions from PRESSURE HEADS

  1. A pitot head is used to measure:
    • A) dynamic minus static pressure.
    • B) static plus dynamic pressure.
    • C) static pressure.
    • D) dynamic pressure.
    Show answer

    B) static plus dynamic pressure.

  2. A static vent is used to measure:
    • A) dynamic pressure minus pitot excess.
    • B) dynamic pressure plus pitot excess.
    • C) atmospheric pressure.
    • D) pitot excess pressure.
    Show answer

    C) atmospheric pressure.
    Vents are sited on either side of the fuselage and feed into a common tube; this has the effect of cancelling out to some extent errors arising from the position of the vents

  3. A pressure head is subject to the following errors:
    • A) position, manoeuvre induced, temperature.
    • B) position, manoeuvre induced.
    • C) position, manoeuvre induced, density.
    • D) position, manoeuvre induced, instrument.
    Show answer

    D) position, manoeuvre induced, instrument.
    When the aircraft is in forward motion, the static pressure sensed is slightly lower than when the aircraft is stationary. This occurs due to suction created by airflow around the static ports. As the aircraft's speed increases, turbulent airflow in the region of the pitot/static heads causes the error to grow, with turbulence further impacting the pitot reading. This error is known as Position Error. Manoeuvre-induc

  4. Turbulent flow around a pressure head will cause:
    • A) density error.
    • B) 95% increase in manoeuvre induced error.
    • C) an increase in the dynamic pressure
    • D) 95% of pressure error.
    Show answer

    D) 95% of pressure error.
    Position Error. Alternatively known as ‘pressure’ error, this arises mainly from the sensing of incorrect static pressure, and is described more fully in the section entitled Pressure Heads.

  5. Pressure heads supply data to the following instruments:
    • A) air data computers, compasses, altimeters, and ASI's.
    • B) standby instruments only, when air data computers fitted.
    • C) altimeters, ASI's, VSI's, machmeters, air data computers.
    • D) all the above plus air driven gyros.
    Show answer

    C) altimeters, ASI's, VSI's, machmeters, air data computers.
    Pressure heads provide readings for either static or pitot pressure. Instruments like altimeters, airspeed indicators (ASI), vertical speed indicators (VSI), machmeters, and air data computers all rely on pitot or static pressure to function .